855-900549-A
Rev. 1
NX7700i/5020M-16
Operation Manual
CAUTION
Before using the product, be sure to read this manual and strictly
adhere to the instructions.
Keep this manual at hand for quick reference as required.
©NEC Corporation 2006
This manual cannot be duplicated or revised without permission from NEC Corp.
The contents of this manual may be changed without prior notice.
NEC Corporation
Download from Www.Somanuals.com. All Manuals Search And Download.
Safety Precautions
Before using the product, read this manual carefully to ensure the proper and safe operation of the product.
Follow the instructions in this manual to avoid physical injuries and damages to property.
Keep this manual at hand for quick reference as required.
The cables supplied with this product are designed to be used solely for this product. Do
not use them for other purposes.
This operation manual uses the following level of notification to ensure the proper and safe operation of the
product:
Failure to follow the instruction with this symbol could result in
WARNING
severe injury or death.
Failure to follow the instruction with this symbol could result in
CAUTION
barns or other physical injury.
There are the following notifications (pictorial symbols) that you have to keep in mind:
Danger of smoke emission or ignition.
Danger of explosion.
Danger of electric shock.
Danger of injury with harmful substances.
Do not disassemble or remodel.
Forbidden.
General instructions to the user.
Pull out the power plug from the outlet, and turn off the circuit breaker on the
distribution panel.
ii
Download from Www.Somanuals.com. All Manuals Search And Download.
WARNING
Do not touch the internal components of the equipment
Nobody except the maintenance personnel should open the door of the equipment.
Do not disassemble, repair or remodel the equipment by yourself.
Do not touch the components inside the equipment or peer into the equipment while
the maintenance personnel opened the door for service work. Failure to follow the instruction
may result in electric shock or injury due to abnormal operation of the equipment.
Do not insert foreign materials into the equipment
Do not insert a metal plate or wire into the equipment through the air vent
or other openings. This may cause fire or electric shock.
Failure processing
If the equipment failed, turn off the circuit breaker on the distribution
panel, or pull out the power plug from the outlet, and contact the
maintenance or sales personnel of NEC.
Emergency processing
If the equipment falls into the precarious state requiring an emergency shutdown,
turn off the AC SW (emergency shutdown switch).
Data that is not saved may be destroyed when the AC SW is pushed during operation. Make clear in what
situation the AC SW should be operated, and keep everyone informed about it. For details, consult the
maintenance or sales personnel of NEC.
CAUTION
Handling of the lithium battery
A lithium battery is used for this equipment.
Incorrect replacement of the battery could cause explosion. Only the battery
recommended by the battery manufacturer or an equivalent type of battery can be used.
Follow the instruction by the battery manufacturer when replacing the battery and
disposing the used battery.
Contact the maintenance or sales personnel of NEC before replacing the battery
and disposing the used battery.
* Battery life is about 5 years. Replacement of the lithium battery (paid) is therefore required once
every five years.
iii
Download from Www.Somanuals.com. All Manuals Search And Download.
Handling of the laser product
A laser product of Class 1, Subchapter J, Chapter 1 of JIS C6802, EN60825, IEC825 and FDA21CFR, is
used for this equipment.
Note) Class 1 lasers are defined in JIC6802, EN60825, IEC825 and FDA 21CFR that they are exempt
lasers or laser systems that cannot, under normal operating condition, produce a hazard, and the
following label is attached to this class of laser product:
クラス1レ-ザ製品
CLASS 1 LASER PRODUCT PER IEC825
LASER KLASSE 1 NACH IEC825
PRODUCTO LASER DE CLASE 1
Complies with 21CFR chapter 1, Subchapter J
Disposing/collecting/recycling the equipment
Contact the sales personnel of NEC before disposing, collecting, or recycling
the equipment.
The labels listed below are attached to the cabinet of this system.
Read the explanation of each label carefully before operating the system.
133–300656–GRP
001
MARKINGS
注※意:搭載品に関しては、インストレーションマニュアルを見ること。
WARNING:See operation Manual for a List of
Equipment to be used with the rack.
AVERTISSEMENT:Voyez au mode d'emploi fourni,
pour un liste des materiels quels peuvent
utiliser avec l'appareil.
031
033
注※意:分電盤の出力を確認後,ユニットを搭載すること。
WARNING:Confirm there is sufficient output
voltage of power distribution from the outlet
box before mounting units.
AVERTISSEMENT:Avant la installation des
materiels, confirmez que la tension de sortie au
socle de raccordement au reseau est suffisante.
103
18kg
40 lbs
MASS>
iv
Download from Www.Somanuals.com. All Manuals Search And Download.
注※意:同型同定格のヒューズと交換すること。
140
150
CAUTION:For continued protection against risk
of fire, replace only with same type and ratings of fuse.
ATTENTION:Pour une protection continue contre
l'incendie,remplacer les fusibles par ceux de meme
type et de meme amperage.
注※意:資格者のみ保守すること。
HAZARD AREA:QUALIFIED SERVICE
PERSONNEL
ONLY
DANGER:RESERVE SEULEMENT AU
PERSONNEL
矢印を上に向けて取り付けること。
163
Install with arrow pointing
upwards.
Monter de maniere a orienter
la fleche vers le haut.
注※意:アースされていない場合には機器を動作させないこと。
CAUTION:HIGH LEAKAGE CURRENT
Grounding circuit continuity is vital for safe operation
of machine
165
NEVER OPERATE MACHINE WITH GROUNDING
CONDUCTOR DISCONNECTED.(see installation instruction)
ATTENTION:MACHINE a FORT COURANT
de FUITE
NE JAMAIS FAIRE FONCTIONNER AVEC FIL DE
TERRE DECONNECT.(voir instruction d'installation)
211
217
注※意:入力電源線は
銅線のみ接続のこと。
"Use Copper
Conductors only"
CAUTION:
N'utilisez que
les conducteurs de cuivre
ATTENTION:
v
Download from Www.Somanuals.com. All Manuals Search And Download.
注※意:カバーを開ける前に入力電源(分電盤)切断のこと。
243
416
CAUTION:Disconnect input power before removing
this cover.
ATTENTION:Couper l'alimentation electrique
avant de demonter ce capot.
注※意:保守時は安定板を引き出すこと。
CAUTION:
PULL OUT STABILIZER WHEN
MAINTAINING.
ATTENTION:
TIRER LE STABILISIEREN.
417
420
422
vi
Download from Www.Somanuals.com. All Manuals Search And Download.
133-314121-GRP
051
MARKINGS
保守者の方へ
警告
WARNING
複数の装置を
同時に引き出さないで下さい。
ラックの破損、転倒などの事故の原因となります。
Do not pull out more than one component at
a time as it may cause damege to the rack
or allow the rack to tip over.
052
053
055
保守者の方へ
警告 WARNING
装置を引き出したり、装置の積み下ろしを行う際は、必ずラック前面
にあるスタビライザを引き出し確実に設置してから作業を行ってください。
スタビライザを引き出さないまま作業を行うと、ラックの破損、転倒など事故の原因となります。
Always extract and install the stabilizers when pulling
out ore unloading components from the rack. Operating on
the rack without the stabilizers in place may cause
damage to the rack or allow the rack to tip over.
保守者の方へ
危険 DANGER
本ラックを床に耐震固定しないで設置する場合、必ずスタビライザを取り付けて設置してください。
スタビライザを取り付けないと、ラックの転倒など事故の原因となります。
設置前に、必ず保守説明書をお読み下さい。
Always install the stabilizers when not bolting to the floor
for seismic restraint. Operating on the rack or allow
the rack to tip over. Please read the Service Manual before
installation.
注意 CAUTION
指をドアに挟まないよう、注意してください。
Take care not to pinch your
finger in the door.
vii
Download from Www.Somanuals.com. All Manuals Search And Download.
243-304367-GRP
001
MARKINGS
243-306629-GRP
001
MARKINGS
002
viii
Download from Www.Somanuals.com. All Manuals Search And Download.
Preface
This document explains how to operate the hardware of the base module, the main body of this system. It is
recommended that the related documents be read in order to make the best use of the above-mentioned
system.
Special techniques are necessary for installing and expanding the system. Please consult our sales
personnel.
Rev. 1, May 2006
Notes:
(1) All rights reserved. This document cannot be reprinted or reproduced partly or entirely without
permission from NEC Corp.
(2) The contents of this document may be changed at any time without prior notice.
ix
Download from Www.Somanuals.com. All Manuals Search And Download.
Contents
Chapter 1
NX7700i/5020M-16 System Overview.................................................................1-1
1.1. Configuration and Specifications of the Base Module ...............................................1-2
1.2. Expandability .............................................................................................................1-6
1.2.1. Adding Processors...............................................................................................1-6
1.2.2. Expanding Memory Capacity ...............................................................................1-6
1.2.3. Adding Cells.........................................................................................................1-6
1.2.4. Adding I/O Modules .............................................................................................1-6
1.2.5. Adding Peripheral Units .......................................................................................1-6
Chapter 2
Base Module........................................................................................................2-1
2.1. Partition Function.......................................................................................................2-2
2.2. Name and Function of Components..........................................................................2-3
2.2.1. Cabinet (Primary Cabinet) ...................................................................................2-3
2.2.2
2.2.3
2.2.4
Base Module........................................................................................................2-4
Expansion Power Bay..........................................................................................2-4
Cell.......................................................................................................................2-4
2.2.5. I/O Module ...........................................................................................................2-4
2.2.6. Power Bay............................................................................................................2-5
2.2.7. iSP .......................................................................................................................2-6
2.2.8. DVD-ROM Unit ....................................................................................................2-7
2.2.8.1.
Loading and Unloading Media .....................................................................2-7
2.2.9. DAT Unit...............................................................................................................2-8
2.2.9.1.
2.2.9.2.
2.2.9.3.
2.2.9.4.
2.2.9.5.
2.2.9.6.
2.2.9.7.
2.2.9.8.
2.2.9.9.
Location of Index Labels ..............................................................................2-8
Notes on Index Labels .................................................................................2-8
Preventing Accidental Erasure of Data.........................................................2-8
Cleaning the DAT Unit..................................................................................2-9
Cleaning Schedule.......................................................................................2-9
Cleaning Medium for the DAT Unit...............................................................2-9
Life of Data Cartridge (Tape) for the DAT Unit .............................................2-9
Handling of the DAT Unit..............................................................................2-9
Notes on the DAT Unit................................................................................2-10
2.2.9.10. Loading and Unloading Digital Audio Tapes...............................................2-10
2.2.10. Notes on Installing the UPS ...............................................................................2-11
2.2.11. System LEDs .....................................................................................................2-13
2.3. Consoles..................................................................................................................2-14
2.3.1. SP Console........................................................................................................2-14
2.4. Service Processor (SP) ...........................................................................................2-16
2.4.1. Console Connection and Login..........................................................................2-16
2.4.1.1.
2.4.1.2.
2.4.1.3.
2.4.1.4.
Type of Console Connections ....................................................................2-16
Accessible Console Functions ...................................................................2-16
Console Status and Login Authentication...................................................2-17
Login and Main Menu.................................................................................2-19
2.4.2. Note ...................................................................................................................2-21
2.4.3. OS (BIOS) Console............................................................................................2-22
2.4.4. Virtual SOP ........................................................................................................2-24
2.4.4.1.
Details of Partition Status Display ..............................................................2-26
2.4.5. SP Command Console.......................................................................................2-27
2.4.5.1.
2.4.5.2.
2.4.5.3.
2.4.5.4.
SP Command Console Buffer ....................................................................2-28
SP Command Prompt ................................................................................2-28
SP Message Header ..................................................................................2-28
SP Command List ......................................................................................2-29
2.4.6. SP Command Reference ...................................................................................2-32
2.4.6.1.
2.4.6.2.
2.4.6.3.
DF (Shut down System Power <override>)................................................2-33
DN (Shut down System Power) .................................................................2-35
DP (System Dump) ....................................................................................2-36
x
Download from Www.Somanuals.com. All Manuals Search And Download.
2.4.6.4.
2.4.6.5.
2.4.6.6.
2.4.6.7.
2.4.6.8.
2.4.6.9.
DT (SP Data and Time)..............................................................................2-37
EN (Environmental Information).................................................................2-38
FV (Firmware Versions) .............................................................................2-44
HC (Hardware Configuration).....................................................................2-45
HE (Help) ...................................................................................................2-71
ML (Message Log) .....................................................................................2-72
2.4.6.10. PC (Power Cycle).......................................................................................2-74
2.4.6.11. RS (Cold Reset System)............................................................................2-75
2.4.6.12. SG (SP/System Setting).............................................................................2-76
2.4.6.13. SR (Save System CMOS/NvRAM) ............................................................2-87
2.4.6.14. UB (Bring up BIOS)....................................................................................2-89
2.4.6.15. UP (Bring up System).................................................................................2-90
Chapter 3
Operation Procedure ...........................................................................................3-1
3.1. System Startup ..........................................................................................................3-1
3.1.1. System Startup Procedure...................................................................................3-1
3.1.2. SP Console Messages.........................................................................................3-5
3.2. System Shutdown......................................................................................................3-7
3.2.1. System Shutdown Procedure...............................................................................3-7
3.2.2. SP Console Messages.......................................................................................3-10
3.3. Emergency System Shutdown with AC SW.............................................................3-11
3.4. AC-LINK (Auto Control) ...........................................................................................3-11
3.5. OS Boot ...................................................................................................................3-13
3.5.1. OS Boot with Boot Manager (Before Installing the OS) .....................................3-13
3.5.2. OS Boot from the EFI (Extensible Firmware Interface) Boot Manager ..............3-14
3.5.3. EFI Shell ............................................................................................................3-15
3.5.4. EFI Shell Commands.........................................................................................3-15
3.5.5. OS Boot from EFI Shell......................................................................................3-18
3.5.6. EFI Devices........................................................................................................3-20
3.5.7. EFI Boot Option Maintenance............................................................................3-23
3.5.7.1.
3.5.7.2.
3.5.7.3.
3.5.7.4.
3.5.7.5.
3.5.7.6.
3.5.7.7.
3.5.7.8.
Boot from a File..........................................................................................3-25
Add a Boot Option......................................................................................3-26
Add Boot Option(s).....................................................................................3-27
Change Boot Order....................................................................................3-27
Manage BootNext Setting ..........................................................................3-28
Set Auto Boot Timeout ...............................................................................3-29
Setting the Network Boot ...........................................................................3-30
Changing BIOS Settings ............................................................................3-32
3.6. System Dump ..........................................................................................................3-34
Chapter 4
Troubleshooting ...................................................................................................4-1
4.1. Troubleshooting .........................................................................................................4-1
Chapter 5
Notes on Handling ...............................................................................................5-1
5.1. Transportation............................................................................................................5-1
5.2. DVD-ROM/CD-ROM..................................................................................................5-1
5.3. Digital Audio Tape......................................................................................................5-1
5.4. Cleaning.....................................................................................................................5-2
5.5. Notes on Installation ..................................................................................................5-3
xi
Download from Www.Somanuals.com. All Manuals Search And Download.
NX7700i/5020M-16 System Overview
Chapter 1
NX7700i/5020M-16 System Overview
This system is a server that implements the following by using the high performance Intel
Itanium2 processor:
• High processing capability
• Open system using the industry standard architecture
• Advanced system management and RAS function
• High system expandability with a host of optional products
Unit: (mm)
(a) Perspective View (Front)
(b) Perspective View (Rear)
Figure. External Views of the Cabinet
1-1
855-900549
Download from Www.Somanuals.com. All Manuals Search And Download.
NX7700i/5020M-16 System Overview
1.1.
Configuration and Specifications of the Base Module
The base module of this system is composed of the following hardware components:
− CELL
Can install one to four Intel Itanium2 processors.
The minimum required memory capacity is 2GB and can be expanded up to 128GB.
− I/O MODULE
Can contain:
Up to 8 PCI cards
A DVD-ROM unit
A DAT unit
Up to 4 HDDs (up to two HDDs when DAT is used)
− POWER BAY
Can contain to 3 DPSs (AC/DC converters).
The iSP of the base module supports the following interfaces as standard equipment:
(1) 10/100Base-TX Ethernet interface for the SP console
(2) Serial (RS-232C) interface for the SP console
Layout of the base module components and system specifications are shown in the subsequent
pages.
855-900549
1-2
Download from Www.Somanuals.com. All Manuals Search And Download.
NX7700i/5020M-16 System Overview
„ Front View
I/O MODULE
POWER BAY
FAN BOX
DPS
„ Rear View
FAN BOX
iSP CARD
INLET BOX
AC SW
Figure. Layout of Parts in the Base Module
1-3
855-900549
Download from Www.Somanuals.com. All Manuals Search And Download.
NX7700i/5020M-16 System Overview
Table. Base Module Specifications
BASE MODULE
Cell (Max. 2 cells can be installed in the base module.)
CPU
Max. No. of processors
Main memory
8 (Max. 4 processors/cell)
Expansion unit
2GB/4GB/8GB
2GB to 128GB
Main memory capacity
I/O module (Max. 2 modules can be installed.)
Max. No. of PCI slots
Max. I/O bandwidth
16 slots (133MHz)
67GB/s
One unit can be installed in the I/O module.
DVD-ROM/CD-ROM mode
DVD-ROM unit
DAT unit
One unit can be installed in the I/O module.
DDS-4 4mm DAT unit
Max. 4 units can be installed in the I/O module (2 units when
DAT is installed).
Magnetic disk unit
Selection from 73GB/146GB/300GB
POWER BAY (One unit can be installed in the base module.)
DPS (Max. 3 units can be installed.)
Note) Components are installed in the cabinet in units of the base module (an expansion
power bay will be mounted depending on the form of power supply). A maximum of four
base modules can be installed in a cabinet.
The expansion power bay is mounted under the base module when power is supplied
from two systems or 100VAC. It depends on the form of power supply.
855-900549
1-4
Download from Www.Somanuals.com. All Manuals Search And Download.
NX7700i/5020M-16 System Overview
Table. Base Module Specifications (Cont’d)
Main Cabinet
Cabinet size/weight Note 2)
Width
600mm
Height
1265/1620/1975mm
1050mm
Depth Note 1)
Weight (in max. configuration) 545Kg
Power supply
Voltage
Single-phase, 200 to 240V±10%
Frequency
50/60Hz±1Hz
Power consumption (in max.
configuration)
13.2kVA
Environmental conditions
Temperature
Operating
Storage
+5°C to +32°C
+5°C to +45°C
Humidity
Operating
Storage
20% to 80% (no condensation)
8% to 80% (no condensation)
Note 1) Three types of cabinets are provided, each having a different height.
Note 2) The depth including the handle of the back door is 1070mm.
1-5
855-900549
Download from Www.Somanuals.com. All Manuals Search And Download.
NX7700i/5020M-16 System Overview
1.2.
Expandability
This section explains the expandability of this system and available configurations.
Contact the maintenance personnel of NEC to replace or
upgrade the system.
CAUTION
1.2.1.
Adding Processors
At least one processor is required for the base module. Using the CPU expansion feature, the
Itanium2 processor can be added one by one. Up to four processors can be installed for each
cell. To install more than four processors, the cell must be added first using the cell expansion
feature. A maximum of 8 processors can be installed in the base module.
1.2.2.
Expanding Memory Capacity
The minimum required memory capacity for the base module is 2GB. This memory capacity can
be expanded up to 64GB for each cell. This means a maximum of 128GB of memory can be
installed in the base module.
2GB, 4GB and 8GB memories are supported at present. For other memories, inquire the sales
personnel of NEC.
1.2.3.
Adding Cells
At least one cell is required for the base module. For system expansion, such as the addition of
processors, the cell must be added first using the cell expansion feature. Up to 2 cells can be
installed in the base module.
1.2.4.
Adding I/O Modules
At least one I/O module is required for the base module. A maximum of two I/O modules can be
installed in the base module.
A maximum of four magnetic disk units can be mounted on the built-in device bay of the I/O
module. The magnetic disk units supported at present are 73GB, 146GB and 300GB HDD. For
other types, contact the sales personnel of NEC.
1.2.5.
Adding Peripheral Units
The iSP is installed in the base module to satisfy various customer’s requirements for system
configurations. The system is designed to connect a wide variety of peripheral units through this
iSP. Peripheral units can also be connected through various types of PCI cards available on the
I/O module.
855-900549
1-6
Download from Www.Somanuals.com. All Manuals Search And Download.
NX7700i/5020M-16 System Overview
BASE MODULE
The minimum 2GB memory
can be expanded up to
64GB for each cell.
Itanium2
SP Console
(Standard)
CELL
RS232C(Console)
Server
management
LAN interface
Ethernet cable
10/100Base - TX
DVD-ROM UNIT
N
E
C
DAT UNIT
I/O MODULE
POWER BAY 0
Expansion POWER BAY
* The expansion power bay is
POWER BAY 1
mounted only when the power
is supplied from two systems
or 100VAC.
Figure. System Configuration
1-7
855-900549
Download from Www.Somanuals.com. All Manuals Search And Download.
Base Module
Chapter 2
Base Module
This chapter covers operations required on the base module of this system.
Locking/unlocking the cabinet
Back door
Front door
Figure. Doors of Cabinet
2-1
855-900549
Download from Www.Somanuals.com. All Manuals Search And Download.
Base Module
2.1.
Partition Function
The base module has the partition function which enables the system to operate as if multiple
units are present on one unit.
The system is capable of partitioning in units of the cell or I/O module within the same base
module. For example, in a system consisting of two cells and two I/O modules, partitioning
shown in the figure below is possible.
Note that each partition should contain at least one cell card and one I/O module (including the
core module).
The partition structure in the base module can be changed with the “hc” command of the SP
command. (For details of the SP command, see 2.4.6 SP Command Reference.)
Partition #0
CELL
Partition #1
CELL
Itanium2
I/O MODULE
Under OS#0
Under OS#1
Figure. Image of Partitions
855-900549
2-2
Download from Www.Somanuals.com. All Manuals Search And Download.
Base Module
2.2.
Name and Function of Components
Cabinet (Primary Cabinet)
2.2.1.
The base module and expansion power bay (POWBAY#1) are installed in the cabinet. The
number of installable base modules depends on the size of the cabinet. A maximum of four
base modules can be installed in the largest cabinet.
The example below shows that the system is installed in the 1620mm high cabinet.
M-zz indicates “U” (unit size) from the bottom is zzU [1U is about 44mm].
The base module is 8U, and POWBAY#1 is 2U in height.
SW PANEL
SW PANEL
M-32
M-30
M-32
M-30
M-25
M-20
M-15
M-10
M-05
M-00
M-25
M-20
M-15
M-10
M-05
M-00
(BASE
MODULE)
(BASE
MODULE)
(POWBAY#1)
(a) Installation of the Base Module
(b) Installation of the Base Module + Power Bay
2-3
855-900549
Download from Www.Somanuals.com. All Manuals Search And Download.
Base Module
2.2.2
Base Module
A base module is composed of cells, iSP cards, I/O modules, power bays, and DPSs.
2.2.3
Expansion Power Bay
The expansion power bay is used only when the power is supplied from two systems or
100VAC. It is never used for a single power supply system.
2.2.4
Cell
A cell is composed of up to four processors, a CPU node controller, a memory controller, and
main memory. The main memory can vary from the minimum 2GB to the maximum 64GB. At
least one cell needs to be installed for the base module. Up to two cells can be installed.
2.2.5.
I/O Module
The I/O module provides 8 PCI slots corresponding to 133MHz PCI-X buses, allowing up to 8
PCI cards to be used.
The PCI card can be inserted or taken out in online mode (hereafter called the “hot swap”) with
some exceptions. Consequently, the base module need not be shut down or rebooted each time
the PCI card is added or replaced. High availability is achieved with this implementation (note
that the OS that supports this implementation is required).
One core module or HDD module is mounted on the I/O module. At least one core module is
required for each partition.
A DVD-ROM unit is installed in the I/O module as standard equipment. In addition, a DAT unit
and up to four 73GB/146GB/300GB magnetic disk units can be installed as optional units.
At least one I/O module is required for the base module.
855-900549
2-4
Download from Www.Somanuals.com. All Manuals Search And Download.
Base Module
2.2.6.
Power Bay
The power bay supplies power to the system. A maximum of three DPSs (a DPS is a system
power supply with a fan) can be installed in the power bay.
The expansion power bay is used only when the power is supplied from two systems or
100VAC.
AC SW
Expansion power bay
(a) Power supply from a single system
(N+1) [200VAC] (Rear View)
(b) Power supply from two systems (2N)
[200VAC] (Rear View)
AC SW
Expansion power bay
(c) Power supply from 100VAC (Rear
View)
2-5
855-900549
Download from Www.Somanuals.com. All Manuals Search And Download.
Base Module
2.2.7.
iSP
One iSP-C card is mounted on the base module as standard equipment. It contains the
following interfaces:
1)
2)
10/100Base-TX Ethernet interface (x1) for SP console
Serial (RS-232C) interface (x1) for SP console
The iSP-C card is shown below.
8
4 3 2
7 6 5
1
(RSC232C)
CNSL
LAN1 LAN0
DSW0
DSW1
Figure. Rear panel of iSP (Installed in the Base Module)
855-900549
2-6
Download from Www.Somanuals.com. All Manuals Search And Download.
Base Module
2.2.8.
DVD-ROM Unit
One DVD-ROM unit can be installed for each I/O module. A DVD-ROM unit is mounted on each
I/O module as standard equipment. The DVD-ROM and CD-ROM media can be used on the
DVD-ROM unit.
2.2.8.1. Loading and Unloading Media
(1) Loading DVD-ROM/CD-ROM
1) Open the front cover, and remove the mask. (loosen the hand screw).
2) Push the Eject button lightly, and the tray pops out.
3) Place DVD-ROM/CD-ROM securely on the tray.
4) Push the Eject button lightly, and the tray goes back in the drive.
(2) Unloading DVD-ROM/CD-ROM
1) Be sure that the DVD-ROM drive access indicator LED (orange) goes off.
2) Push the Eject button lightly, and the tray pops out.
3) Take out DVD-ROM/CD-ROM.
Be careful not to touch the tray while it recesses in the drive
unit to prevent hand injury.
CAUTION
DVD-ROM
DVD-ROM
DVD or CD-R/RW
Eject button
Tray
Figure. Loading and Unloading DVD-ROM/CD-ROM
2-7
855-900549
Download from Www.Somanuals.com. All Manuals Search And Download.
Base Module
2.2.9.
DAT Unit
An optional DAT unit can be installed in the I/O module.
2.2.9.1. Location of Index Labels
The figure below shows the location of index labels attached to the digital audio tape.
NEC
Figure. Index Labels on the Digital Audio Tape
2.2.9.2. Notes on Index Labels
(1) Attach index labels properly as shown in 2.2.9.1. Be sure to write the start date on these
labels.
(2) Change the labels when the DAT is used for other purpose. Remove the old labels before
attaching the new labels.
(3) When using index labels other than those supplied by NEC, make sure that they are in the
right size and easy to remove without remnant paste.
2.2.9.3. Preventing Accidental Erasure of Data
Open the write protect slider next to the side label of the cartridge to prevent data on the DAT
from being erased by accident. Write on the DAT is permitted by closing the write protect slider.
Figure. Preventing Accidental Erasure of Data on DAT (Write Protect)
855-900549
2-8
Download from Www.Somanuals.com. All Manuals Search And Download.
Base Module
2.2.9.4. Cleaning the DAT Unit
Wipe off the dusts on the DAT unit. See 2.2.9.5 to 2.2.9.7 for how to clean the DAT unit.
2.2.9.5. Cleaning Schedule
How often the DAT unit should be cleaned depends on the operating environment. The table
below will be of some help.
Frequency of using data cartridge
Use of one cartridge per day
Use of 2 to 3 cartridges per day
Use of more than 3 cartridges per day
Cleaning schedule
Once a week
Twice a week
Everyday
Cleaning is important to remove accumulated dust on the magnetic head caused by running
tapes and surrounding environment. Periodic cleaning is recommended.
2.2.9.6. Cleaning Medium for the DAT Unit
The cleaning cartridge can be used approximately 50 times.
Clean the drive head with this cartridge before using the new data cartridge. It is recommended
to clean the head prior to writing or reading the DAT. Clean the head once a month even though
the DAT unit is not used.
2.2.9.7. Life of Data Cartridge (Tape) for the DAT Unit
The life of data cartridge according to the frequency of use is shown below. It may be shortened
depending on the operating environment (temperature, humidity, dust, etc.).
Frequency of using data cartridge
Once a week/volume
Life
Approx. one year
Three times a week/volume
Everyday
Approx. half a year
Approx. three months
The data cartridge is worn out every time it is read or written. It should be noted that using the
worn-out cartridge will cause trouble. To prevent trouble caused by aged deterioration, storage
of the data cartridge should not exceed five years.
2.2.9.8. Handling of the DAT Unit
Keep the following in mind for proper operation of the DAT unit:
• Do not move the DAT unit with the cleaning or data cartridge loaded.
• Take out the cleaning or data cartridge before turning off the DAT unit.
• Do not leave the DAT unit for a prolonged period of time with the cleaning or data cartridge
loaded.
2-9
855-900549
Download from Www.Somanuals.com. All Manuals Search And Download.
Base Module
2.2.9.9. Notes on the DAT Unit
Avoid placing the DAT unit in the following locations as much as possible to prevent trouble in
the DAT unit:
• Near the printer (to prevent toner or paper powder dusts)
• By the window or near the passage way (to prevent soil dusts)
• On the carpet (to prevent dust generation)
2.2.9.10. Loading and Unloading Digital Audio Tapes
How to load and unload a digital audio tape is explained below.
(1) Loading a digital audio tape
1) Remove the front filter cover of the I/O enclosure (loosen the hand screw).
2) Hold the DAT lengthwise with the DAT label oriented to the left, and insert it into the
drive vertically and slowly.
3) Keep pushing the tape slowly until you feel it touching the stopper inside the drive and
being locked in the drive. When the tape is locked, a clicking sound is heard.
(2) Unloading a digital audio tape
1) Be sure that the DAT drive access indicator LED (green) goes off.
2) Push the Eject button at the lower part of the DAT unit lightly.
3) The DAT slides out from the drive.
4) Take out the DAT from the drive vertically and slowly.
DAT units
Figure. DAT Units
855-900549
2-10
Download from Www.Somanuals.com. All Manuals Search And Download.
Base Module
2.2.10. Notes on Installing the UPS
To installed the UPS, remove the signal cable for power control (on/off), and mount a jumper
connector (shown in the figure below).
This system has three forms of power supplies [a), b) and c) below]. It should be noted that the
location of the jumper connector differs depending on the form of power supply.
Figure. Jumper Connector for Installing the UPS
a) Power supply from a single system
Location on the inlet box: P1
AC SW
P1
2-11
855-900549
Download from Www.Somanuals.com. All Manuals Search And Download.
Base Module
b) Power supply from two systems
Location on the inlet box: P1
AC SW
P1
Location on the expansion power bay: P3
CB1
P3
c) Power supply from 100VAC
Location on the inlet box: P1
AC SW
P1
Location on the expansion power bay: P5, P6, P7
P5 P6 P7
AC SW
855-900549
2-12
Download from Www.Somanuals.com. All Manuals Search And Download.
Base Module
2.2.11. System LEDs
System LEDs are located at the upper left of the front panel of the base module and indicate the
system status. The views when the front panel is opened (a) and closed (b) are shown below.
LED CARD
The LEDs from the top indicate:
Status
DC ON/OFF
AC ON/OFF
(a) LEDs with the front panel opened
LED
(b) LEDs with the front panel closed
„ LED Indication
LED name
Color & status
Description
ON
OFF
AC ON
AC OFF
AC ON/OFF
Green
ON
OFF
ON
Flash
OFF
DC ON (48VDC is supplied.)
DC OFF
System is online.
System is in maintenance mode.
Other (error, offline)
DC ON/OFF
Status LED
Green
Green
2-13
855-900549
Download from Www.Somanuals.com. All Manuals Search And Download.
Base Module
2.3.
Consoles
The base module contains console interfaces as standard equipment. The consoles connected
to the interfaces provided by the iSP are roughly classified into two:
• OS console (also called the system console or SW console) to display BIOS/OS messages
• SP console (also called the HW console) to display SP messages
2.3.1.
SP Console
The SP console required:
• Recommended Windows2003 operation environment
• One LAN port
The console connection diagram is shown in the subsequent page. The iSP-C standard I/O
interface connected to “Console PC” in this figure is:
• Ether Port (10/100Base-TX)
855-900549
2-14
Download from Www.Somanuals.com. All Manuals Search And Download.
Base Module
BASE MODULE
SYS BP
CELL CARD
I/O MODULE
iSP-C CARD
LAN
CRT
MOUSE/
KEYBOARD
Console PC
OS console
OS
console
SP
console
RS232C
modem
modem
ALIVE
console
Figure. Console Connection Diagram
2-15
855-900549
Download from Www.Somanuals.com. All Manuals Search And Download.
Base Module
2.4.
Service Processor (SP)
This system contains interfaces to offer advanced system management and RAS function to the
user. The service processor (hereafter called the “SP”) in the iSP implements these capabilities.
2.4.1.
Console Connection and Login
2.4.1.1. Type of Console Connections
The iSP supports two types of console connections: i.e. local console connection via serial port
and LAN console connection via TCP port 5001.
Either type of connection provides completely identical user interface, except that all LAN
configuration such as IP address setting can only be done from the local console.
For the details of serial port and LAN configuration, refer to the “SG Command Reference.”
local
iSP-card
null modem cable
console
Serial connector 0
LAN connector
LAN
TCP5001
console
Figure. Type of Console Connections
2.4.1.2. Accessible Console Functions
The console operator has access to the following console operations:
• iSP operation using SP commands
• Redirection of OS (BIOS) serial (inside the CPU) console
• Virtual SOP display
855-900549
2-16
Download from Www.Somanuals.com. All Manuals Search And Download.
Base Module
2.4.1.3. Console Status and Login Authentication
To gain access to console operation, you must first login to the iSP.
When you login to the iSP, the Main Menu opens. The Main Menu has three options: i.e. Virtual
SOP, OS Console, and SP Command Console.
• Virtual SOP provides periodical updates to system operation status for each partition.
• OS Console redirects serial I/Os as viewed from the OS (including BIOS).
• SP Command Console lets you monitor iSP messages for system or maintenance operations
and enter commands into the iSP. Only the commands required for system operation can be
executed on the SP Command Console.
Factory default login account and password
Type
Login account
Login password
Default
spfw
nec
The numbers of consoles that can be attached to the system at a time are: Up to one OS
Console for each partition; up to nine Virtual SOPs and up to one SP Command Console
throughout the entire system.
OS Console and SP Command Console include two types: i.e. one that allows console input
(with operational authority) and the other that only allows message displays (with no operational
authority). The OS Console that is first attached to the specified partition is given operational
authority. Similarly, the SP Command Console that is first attached to the system is given
operational authority. Once a console is attached with no operational authority given to it, it
cannot acquire operational authority until the existing console with operational authority is
disconnected or its operational authority is removed in the Main Menu.
If key entry is attempted on a console without operational authority, it will output the message,
“This console is mirror console.”
2-17
855-900549
Download from Www.Somanuals.com. All Manuals Search And Download.
Base Module
Serial console
inoperative
TCP-5001 not
connected
Press ESC
Connect TCP5001
Choose Exit
Choose Exit
iSP login prompt
Login password
required
Main Menu
Enter ^B
Enter ^B
Enter ^B
Choose SOP
Choose SP
Choose OS
OS Console
SP Console
Virtual SOP
Normal Mode
CM command
Password required
SP Console
Maintenance Mode
Figure. Console Mode Status Transitions
855-900549
2-18
Download from Www.Somanuals.com. All Manuals Search And Download.
Base Module
2.4.1.4. Login and Main Menu
Immediately after a console is attached to the iSP, login prompts appear on the console, waiting
for user login. When you enter your login account name and password, the Main Menu opens.
Login account and password are both case-sensitive. Alphabetic letters used in the Main Menu
are not case-sensitive, however (e.g. “e” and “E” are interpreted as the same character).
(Screen Example)
Description
No.
Integrated Service Processor.
Cabinet-ID:xx, Location:iSPy, State:ssssss
(a)
iSP login: spfw<ENTER>
iSP password: xxxxxxxx<ENTER>
(b)
Copyright (C) 2005 NEC Corporation, All Rights Reserved.
Welcome to Integrated Service Processor.
(c)
iSP FW version : 01.00 generated on 01/01/2005 19:20:33
iSP MAIN MENU
0) OS(BIOS) serial console of partition#0 (INITIALIZING )
1) OS(BIOS) serial console of partition#1 (RUNNING
2) OS(BIOS) serial console of partition#2 (STOPPED
3) OS(BIOS) serial console of partition#3 (FAULT
4) OS(BIOS) serial console of partition#4 (POWER OFF
5) OS(BIOS) serial console of partition#5 (RUNNING
)
)
)
)
)
(d)
6) OS(BIOS) serial console of partition#6 (NOT CONFIGURED)
7) OS(BIOS) serial console of partition#7 (NOT CONFIGURED)
V) Virtual System Operator Panel
S) iSP commands
E) Exit
DISCONNECTALL) disconnect all console connections
iSPyz>
(e)
2-19
855-900549
Download from Www.Somanuals.com. All Manuals Search And Download.
Base Module
(Description)
Description
Description
No.
xx is a cabinet ID identifying a particular cabinet in a multi-cabinet system
(“system number” itself set with an SG command).
y is the location of the iSP Card (0 or 1).
ssssss represents “master” if the SP is assigned as master, “backup”* if it is
assigned as backup, and “undetermined” if it is assigned as neither master nor
backup.
(a)
Enter your login account and password at these prompts.
The password is not echoed.
Version information for iSPFW
(b)
(c)
The Main Menu.
OS Console and Virtual SOP can be chosen only if the iSP is assigned as the
master.
The OS Console menu includes the summary status of partitions.
Main Menu prompt.
y is the location of the iSP Card (0 or 1).
(d)
(e)
z is “m” if the SP is assigned as the master, “b” if it is assigned as the backup,
and “u” if it is assigned as neither master nor backup.
* The “backup” indicator will not appear if no backup SP exists.
If maintenance operation or SPFW fails, the BOOT FW may boot up. In this case, the screen
information is only limited to that needed for the BOOT FW (no login entry fields appear).
(Screen Example…BOOT FW)
Description
No.
iSP BOOT MAIN MENU
S) iSP commands
E) Exit
DISCONNECTALL) disconnect all console connections
iSPy*>
855-900549
2-20
Download from Www.Somanuals.com. All Manuals Search And Download.
Base Module
• Possible Events (including operator entries) and System Responses
Event
System Response
Login account or password was wrong.
The login prompt reappears after the message
“incorrect” comes on.
Login account or password rejected 3
times consecutively.
The console is disconnected.
No operations made for 5 minutes on the
The console is disconnected after the message
login account or password prompt screen. “timeout” appears.
A letter not specified in the menu was
entered.
The menu reopens.
No operation made for 5 minutes on the
Menu screen.
The console is disconnected after the message
“timeout” appears.
The menu became invalid after iSP
master assignment has been changed.
The invalid menu or prompt is not identified
immediately.
If you make a selection in the invalid menu, that
selection is rejected and a new menu opens.
OS (BIOS) Serial Console Redirection is chosen.
A value from 0 to 7 selected.
(valid only on the master iSP)
S selected.
(valid regardless of master/backup
assignment)
SP Command Console is chosen.
Virtual SOP is chosen.
V selected.
(valid only on the master iSP)
E selected.
DISCONNECTALL selected.
The current console connection is disconnected.
All TCP connections to the iSP other than the
current console connection are disconnected and
the screen is forcibly returned to the Main Menu
in case of serial connection console.
This emergency action might be needed if
console operation is prohibited when actually
disconnected TCP connections remain alive
under the iSP management due to client’s illegal
access.
The number of simultaneous connections
allowable for the selected mode was
exceeded.
The screen returns to the Main Menu after
showing a message “N connections to the
selected mode are already established. Try it
later.”
2.4.2.
Note
While in serial or OS console connection, characters that are shown on the console screen may
be disturbed due to redirection made in a half way of ESC sequence.
2-21
855-900549
Download from Www.Somanuals.com. All Manuals Search And Download.
Base Module
2.4.3.
OS (BIOS) Console
If OS (BIOS) Console is chosen from the iSP Main Menu, I/O to/from the serial controller is
redirected as viewed from the OS (BIOS).
To return to the Main Menu, enter “^B” (press the B key while holding down the CTRL key).
While the OS (BIOS) Console I/O is redirected, the screen displays and operations depend
solely on the BIOS or OS that runs in that partition, and not on the iSPFW.
OS (BIOS) Console redirection is only allowed for the master iSP.
(Screen Example)
Description
No.
iSP MAIN MENU
0) OS(BIOS) serial console of partition#0 (INITIALIZING )
1) OS(BIOS) serial console of partition#1 (RUNNING
2) OS(BIOS) serial console of partition#2 (STOPPED
3) OS(BIOS) serial console of partition#3 (FAULT
4) OS(BIOS) serial console of partition#4 (POWER OFF
5) OS(BIOS) serial console of partition#5 (RUNNING
)
)
)
)
)
6) OS(BIOS) serial console of partition#6 (NOT CONFIGURED )
7) OS(BIOS) serial console of partition#7 (NOT CONFIGURED )
V) Virtual System Operator Panel
S) iSP commands
E) Exit
DISCONNECTALL) disconnect all console connections
iSPyz> 0<ENTER>
***** redirection of serial console 0 *****
(a)
(b)
***** enter CTRL+B to quit
:
*****
:
(c)
:
:
:
<CTRL>+<B>
***** returned from serial console 0 redirection *****
(d)
(e)
855-900549
2-22
Download from Www.Somanuals.com. All Manuals Search And Download.
Base Module
(Description)
Description
No.
Description
If a value (0 to 7) is entered, I/O is redirected to OS Console within the
corresponding partition.
(a)
(b)
(c)
(d)
An opening message for OS Console redirection
All I/Os made in OS Console redirection depends on the OS or BIOS.
Enter ^B to quit OS Console redirection.
An end of redirection message.
The screen returns to the Main Menu after this message.
(e)
• Possible Events (including operator entries) and System Responses
Event
^B (CTRL+B) entered.
System Response
The screen shows an “Exit OS (BIOS) Console”
message, and then returns to the Main Menu
and prompts.
OS (BIOS) Console became invalid after
iSP master assignment changed.
The screen shows an “Exit OS (BIOS) Console”
message, and then returns to the Main Menu
and prompts.
There are no partitions on display after an
SP command was entered.
The screen shows an “Exit OS (BIOS) Console”
message, and then returns to the Main Menu
and prompts.
2-23
855-900549
Download from Www.Somanuals.com. All Manuals Search And Download.
Base Module
2.4.4.
Virtual SOP
If Virtual SOP (Virtual System Operator Panel) is chosen from the Main Menu, Virtual SOP
appears on the console screen. Virtual SOP periodically lists outlined status information of all
the existing partitions.
To return from Virtual SOP to Main Menu, enter “^B” (press the B key while holding down the
CTRL key).
Virtual SOP is selectable only if the iSP is assigned as the master.
(Screen Example)
Description
No.
iSP MAIN MENU
0) OS(BIOS) serial console of partition#0 (INITIALIZING )
1) OS(BIOS) serial console of partition#1 (RUNNING
)
)
2) OS(BIOS) serial console of partition#2 (STOPPED
:
:
7) OS(BIOS) serial console of partition#7 (NOT CONFIGURED )
V) Virtual System Operator Panel
S) iSP commands
E) Exit
DISCONNECTALL) disconnect all console connections
iSPyz> V<ENTER>
----- Virtual System Operator Panel ---------- 01/31/2005,19:30:20 -----
(a)
00 0 HW INITIALIZING yyyyyy
BIOS messages
SP messages
00 1 RUNNING
BIOS messages
SP messages
yyyyyy
yyyyyy
yyyyyy
00 2 STOPPED
BIOS messages
SP messages
yyyyyy
yyyyyy
00 3 FAULT
BIOS messages
SP messages
(b)
00 4 POWER OFF
00 5 RUNNING
BIOS messages
SP messages
BIOS messages
SP messages
00 6 NOT CONFIGURED yyyyyy
BIOS messages
SP messages
00 7 NOT CONFIGURED yyyyyy
BIOS messages
SP messages
----- Enter CTRL+B to quit ---------------------------------------------
:
<CTRL>+<B>
(c)
(d)
855-900549
2-24
Download from Www.Somanuals.com. All Manuals Search And Download.
Base Module
(Description)
Description
Description
No.
(a)
(b)
Virtual SOP appears if V is entered at this prompt.
Virtual SOP screen.
SP messages shared for all the partitions or those not concerned with partitions
appear here.
Virtual SOP periodically appears until these keys are pressed.
Entering ^B quits Virtual SOP.
(c)
(d)
(e)
The screen returns to the Main Menu.
• Possible Events (including operator entries) and System Responses
Event
^B (CTRL+B) entered.
System Response
The screen returns to the Main Menu and
prompts.
Virtual SOP became invalid after iSP master The screen shows a message “Exit Virtual
assignment was changed.
SOP,” and then returns to the Main Menu and
prompts.
2-25
855-900549
Download from Www.Somanuals.com. All Manuals Search And Download.
Base Module
2.4.4.1. Details of Partition Status Display
The status information for each partition consists of the following items:
1
2
3
4
5
xx N sssssssssssssss cccccc
ttttttttttttttttttttttttttttttt
uuuuuuuuuuuuuuuuuuuuuuuuuuuuuuu
6
No.
(1)
Item
Description
Numeral
Represents the system No. Fixed to 00 for all other
models.
(2)
(3)
Numeral (0-7)
Character string
POWER OFF
STOPPED
Denotes the partition number.
Represents partition states.
Indicates DC OFF state.
Indicates DC ON, No Failure, and Halt state.
Means that the iSP is initializing the HW. BIOS is still not
booted.
HW INITIALIZING
SW INITIALIZING
OS BOOTING
RUNNING
Means that the system is being initialized by BIOS.
Means that the OS is being booted (HP-UX only).
Means that control is passed to EFI after system
initialization by BIOS is complete.
FAULT
Means that the system is in Halt state due to failure.
Means that the ISP is shutting down the HW.
Means “Not Configured.”
Represents the latest chassis code sent from the BIOS
or OS.
SHUT DOWN
NOT CONFIGURED
6 digit hex number
(4)
(5)
Character string
Character string
Four-digit error code provided by BIOS.
It is cleared when the system is booted next time, or
with the CS command.
Warning or error message provided by the SP, shown in
the same format as Activity logs. For long messages,
their tail part will be omitted.
(6)
It is cleared when the system is booted next time, or
with the CS command.
855-900549
2-26
Download from Www.Somanuals.com. All Manuals Search And Download.
Base Module
2.4.5.
SP Command Console
If SP Command is chosen from the iSP Main Menu, SP Command Console appears on the
console screen.
To return from SP Command Console to the Main Menu, enter “^B” (press the B key while
holding down CTRL).
Some SP commands are only valid on the master iSP.
(Screen Example)
Description
No.
iSP MAIN MENU
0) OS(BIOS) serial console of partition#0 (INITIALIZING )
1) OS(BIOS) serial console of partition#1 (RUNNING
2) OS(BIOS) serial console of partition#2 (STOPPED
3) OS(BIOS) serial console of partition#3 (FAULT
4) OS(BIOS) serial console of partition#4 (POWER OFF
5) OS(BIOS) serial console of partition#5 (RUNNING
)
)
)
)
)
6) OS(BIOS) serial console of partition#6 (NOT CONFIGURED)
7) OS(BIOS) serial console of partition#7 (NOT CONFIGURED)
V) Virtual System Operator Panel
S) iSP commands
E) Exit
DISCONNECTALL) disconnect all console connections
iSPyz> S<ENTER>
:
(a)
(b)
(c)
:
:
:
:
<CTRL>+<B>
(Description)
Description
Description
No.
(a)
(b)
(c)
SP Command Console appears if S is entered at this prompt.
You can enter SP commands and monitor SP messages until ^B is entered.
CTRL+B quits SP Command Console. The screen returns to the Main Menu.
2-27
855-900549
Download from Www.Somanuals.com. All Manuals Search And Download.
Base Module
2.4.5.1. SP Command Console Buffer
The output from SP Command Console may contain some critical information such as causes of
system status changes. Also when the iSP is running in LAN Console mode, it is not possible to
monitor the console output until LAN Console connection is established after the iSP boots up.
For these reasons, the iSP is provided with a buffering capability that buffers a certain amount
of messages that are output before SP Command Console connection is established.
The buffer has a size of approx. 1000 lines, capable to save the latest 1000 lines of output
messages.
The buffer contents can be listed with the “ML command.”
2.4.5.2. SP Command Prompt
When in SP Command mode, pressing the [ESC] key shows either of the following command
prompts.
Prompt
iSPyz:--->
2.4.5.3. SP Message Header
SP messages are, in general, output with the following headers attached to them.
No message headers are attached to interactive prompts or messages used in SP commands,
however.
Message Header
[iSPyz:INFO.ccccc] string
Description
Information message:
ccccc represents a message ID.
string represents the message body.
Warning message
[iSPyz:WARN.ccccc] string
[iSPyz:ERRORccccc] string
Error message
855-900549
2-28
Download from Www.Somanuals.com. All Manuals Search And Download.
Base Module
2.4.5.4. SP Command List
The following tables contain SP command lists by category:
System Control
iSP
state
CMD
command name
function
The iSP turns off the DC power of the
specified partition without notifying the
SW (OS) even if it is running.
If the specified partition is in S0 state,
the iSP only generates the SCI
(POWBTN). Otherwise, the iSP turns
off the DC power directly.
The iSP generates the INIT signal to
the specified partition. SW (OS) will
enter its dump routine.
Shut down System power
(override)
DF
m
m
m
DN
DP
Shut down System power
System Dump
The iSP turns off the DC power of the
specified partition without notifying the
SW (OS) even if it is running, turns on
the DC power, initializes HW and
hands off the control to the BIOS.
The iSP initializes the specified
partition without notifying the SW (OS)
even if it is running.
The iSP turns on the DC power of the
specified partition and initializes HW
and hands off the control to the BIOS.
The iSP turns on the DC power of the
specified partition and initializes HW
and hands off the control to the BIOS.
The BIOS will boot the Operating
System.
PC
Power Cycle
m
RS
UB
Cold Reset System
Bring up BIOS
m
m
UP
Bring up System
m
“m”: Commands can be executed only on the master iSP.
2-29
855-900549
Download from Www.Somanuals.com. All Manuals Search And Download.
Base Module
(Reference) System Status Transitions and System Control Commands
DN/DP
DF
(only trigger)
PC
Ready
DC OFF
SW running
UP/PC
RS
DN/DF
UP/PC/RS
DC ON
Not running
Figure. System Status Transitions and System Control Commands
Note) When the UB command is used for system boot, the system always halts at the
EFI Shell screen. Operation cannot therefore be continued if the system is started
and stopped using, for example, the automatic power control feature, or rebooted
following error detection. If the system halts at the EFI Shell screen, the OS
cannot boot. Be sure to use the UP command to boot the OS. When you use the
UB command for changing the EFI settings, shut down the system and then
reboot it with the UP command.
855-900549
2-30
Download from Www.Somanuals.com. All Manuals Search And Download.
Base Module
Configuration
iSP
state
CMD
command name
function
Display and/or modify the hardware
configuration including the
HC
Hardware Configuration
m
configuration about partitioning.
Normal mode other commands
iSP
state
CMD
command name
function
Display the SP RTC (Real Time
Clock) and set it.
DT
SP Date and Time
m/b/u
Display the environmental information
such as the power status and the
temperature sensors.
EN
Environmental Information
m
Display the iSP FW version and BIOS
version.
FV
HE
ML
Firmware Version
Help
m/b/u
m/b/u
m/b/u
Display the help information.
Message Log
Display the iSP’s message buffer.
Settings
iSP
state
CMD
command name
function
Set up the settings about the iSP,
system and partitions. Some settings
are only available in MNT mode.
Save and/or restore the system
CMOS/NvRAM.
SG
SR
SP/System Setting
m/b/u
m
Save system CMOS/
NvRAM
2-31
855-900549
Download from Www.Somanuals.com. All Manuals Search And Download.
Base Module
2.4.6.
SP Command Reference
This section provides command reference describing the details of SP commands.
Command availability on the master iSP, backup iSP, and undetermined iSP is indicated on the
first page of each command.
(Legend)
m
X
b
u
m: Command validity on the master iSP. X denotes “valid.”
b: Command validity on the backup iSP. X denotes “valid.”
u: Command validity on the undefined iSP. X denotes “valid.”
The example above indicates that the commands are valid only if the iSP is assigned as the
master.
The SP commands and subcommands are not case-sensitive. For this reason, case-sensitive
data such as accounts and passwords is clearly indicated.
[Note]
* When the following list (a list of codes indicating the system configuration) is included in the
command description, this system corresponds to 8Way:
• 8Way
• 32Way
• ISPF
If the above indication is omitted, this description is common across the system.
855-900549
2-32
Download from Www.Somanuals.com. All Manuals Search And Download.
Base Module
2.4.6.1. DF (Shut down System Power <override>)
m
X
b
u
* The command is executable to the active partition (after automatic system boot/UP
command execution).
Function:
This command is used to shut down the system DC power.
It shuts down the system power overriding the current OS or BIOS state, notifying nothing to
them. (It is equivalent to a Power button override on systems having a physical Power button.)
(Screen Example)
Description
No.
iSPyz:---> df<ENTER>
CAUTION:Systempowerwill beturnedoffwithoutany noticetothesoftwares
even if they are running.
Enter partition number (0-7/all/CR=exit) : all<ENTER>
Execute OK? (y/[n]) y<ENTER>
(a)
(b)
DF command was accepted. System power of all partitions will be turned off
soon.
(c)
mm/dd/yyyy HH:MM:SS 0------- System shutdown started. (SPFW:Rxx.xx)
:
(d)
*************************************************
* Waiting 2 minutes for cooling components. *
* DC power is still active.
*************************************************
* DO NOT turn off AC power.
*
(e)
(f)
*
*************************************************
mm/dd/yyyy HH:MM:SS 0------- System shutdown completed. (SPFW:Rxx.xx)
[iSP0m:INFO.2042]
************************************************
* All DC power has been turned off.
* You can turn off AC power.
*
*
************************************************
2-33
855-900549
Download from Www.Somanuals.com. All Manuals Search And Download.
Base Module
(Description)
Description
Description
No.
Enter the target partition number at this prompt.
(a)
(b)
If “all” is specified, all the existing partitions are the target of this command.
The partition numbers that can be specified depend on models.
A confirmation message appears.
If you are sure to continue command execution, enter “y.”
A “DF command accepted” message appears.
Actual processing will progress in the background.
(c)
(d)
Shows background command execution in progress.
The message here indicates that you have to wait for 2 minutes for the system
to cool off before the Power Bay is shut down.
It won’t appear if there are active partitions somewhere.
The message here indicates that the DC power in the Power Bay is shut down
and you are ready to shut off the system AC power.
(e)
(f)
It won’t appear if there are active partitions somewhere.
855-900549
2-34
Download from Www.Somanuals.com. All Manuals Search And Download.
Base Module
2.4.6.2. DN (Shut down System Power)
m
X
b
u
* The command is executable to the active partition (after automatic system boot/UP
command execution).
Function:
This command is used to shut down the system DC power.
It shuts down the system DC power only if the software is not running (not in S0 state).
If the system software (OS or BIOS) is running (S0 state), this command only reports a Power
Button interrupt to the software. The interrupt service depends on the software (the software
may ignore the interrupt or perform a shut-down).
The software may not be able to service the power button interrupt due to stall or other cause
even if the iSP recognizes that the software is running. In this case use the DF command to
force a system power shut-down.
(Screen Example)
Description
No.
iSPyz:---> dn<ENTER>
System power will be turned off if the software(OS) is NOT running.
Onlypowerbuttoninterruptwillbegeneratedifthesoftware(OS)isrunning.
Ifyouwanttoturnedoffthesystempowerinanysystemstate,useDFcommand.
Enter partition number (0-7/all/CR=exit) : 0<ENTER>
Execute OK? (y/[n]) y<ENTER>
(a)
(b)
DN command was accepted. System power of all partitions will be turned off
or power button interrupt will be generated soon.
(c)
[iSPyz:INFO.ccc] partition 0 : power button interrupt.
mm/dd/yyyy HH:MM:SS 0------- System shutdown started. (SPFW:Rxx.xx)
:
(d)
:
mm/dd/yyyy HH:MM:SS 0------- System shutdown completed. (SPFW:Rxx.xx)
(Description)
Description
Description
No.
Enter the target partition number here.
If “all” is specified, all the existing partitions are the target of this command.
A confirmation message appears.
If you are sure to continue command execution, enter “y.”
A “DN command accepted” message appears.
Actual processing progresses in the background.
The same message as that shown in Section 1.5.2, “DN Command Screen
Example” appears.
(a)
(b)
(c)
(d)
2-35
855-900549
Download from Www.Somanuals.com. All Manuals Search And Download.
Base Module
2.4.6.3. DP (System Dump)
m
X
b
u
* The command is executable to the active partition (after automatic system boot/UP
command execution).
Function:
This command causes a Dump interrupt to the system after a system dump is taken.
Whether a system dump is actually taken or not, or a system reset is subsequently activated or
not, depends on the system software (OS or BIOS). This command only causes a Dump
interrupt.
Nothing will happen, of course, if the software is not running.
(Screen Example)
Description
No.
iSPyz:---> dp<ENTER>
Dump button interrupt will be generated.
Enter partition number (0-7/all/CR=exit) : all<ENTER>
Execute OK? (y/[n]) y<ENTER>
(a)
(b)
(c)
DP command was accepted. Dump button interrupt will be generated soon.
[iSPyz:INFO.ccc] partition 0 : dump button interrupt.
[iSPyz:INFO.ccc] partition 1 : dump button interrupt.
:
:
:
(d)
(Description)
Description
Description
No.
Enter the target partition number here.
If “all” is specified, all the existing partitions are the target of this command.
A confirmation message appears.
If you are sure to continue command execution, enter “y.”
A “DP command accepted” message appears.
Actual processing progresses in the background.
Shows progress in the background.
(a)
(b)
(c)
(d)
855-900549
2-36
Download from Www.Somanuals.com. All Manuals Search And Download.
Base Module
2.4.6.4. DT (SP Data and Time)
m
X
b
X
u
X
* Always valid without regard to the current system status.
Function:
This command is used to show iSP’s internal real-time clock.
(Screen Example … Normal Mode)
Description
No.
iSPyz:---> dt<ENTER>
current iSP RTC : 19:20:57,03/31/2005 +09:00
synchronized with NTP server (10.20.30.40)
DT command terminated.
(a)
(Description)
Description
Description
No.
(a)
This command shows the present time before quitting.
2-37
855-900549
Download from Www.Somanuals.com. All Manuals Search And Download.
Base Module
2.4.6.5. EN (Environmental Information)
m
X
b
u
* Always valid without regard to the current system status.
Function:
This command is used to list system environmental data including temperature sensor data,
FAN error, and so on.
Note that part of the environmental monitoring functions are not available to inactive
components.
The temperature sensor threshold shown in the following Screen Example may not reflect the
actual threshold.
(Screen Example)
Description
No.
iSPyz:---> en<ENTER>
select display mode? (i[nteractive per page]/a[ll]/CR=exit) : i<ENTER>
(32Way: For one or two AC power receiving systems)
---- Power Bay Units ------------------------------- 19:20:57,01/31/2005 ----
(a)
state DPS0
DPS1
---
DPS2
DPS3
DPS4
DPS5
---
* MAIN POWBAY0 ON
---
---
ALARM
*
POWBAY1 ON
EXT POWBAY2 OFF
POWBAY3 OFF
---
NORESP ---
---
---
---
---
---
---
---
---
-----------------------------------------------------------------------------
(8Way/ISPF: For one or two AC power receiving systems)
---- Power Bay Units ------------------------------- 19:20:57,01/31/2005 ----
(b)
state DPS0
* MAIN POWBAY0 ON ---
* EXT POWBAY1 ON
DPS1
---
DPS2
DPS3
DPS4
---
DPS5
---
ALARM ---
---
NORESP ---
-----------------------------------------------------------------------------
ISPF does not have two AC power receiving systems.
(8Way/ISPF receiving 48 VDC)
---- Power Bay Units ------------------------------- 19:20:57,01/31/2005 ----
state
EXT POWBAY1 ON
855-900549
2-38
Download from Www.Somanuals.com. All Manuals Search And Download.
Base Module
(32Way)
---- MAIN cabinet FANs ----------------------------- 19:20:57,01/31/2005 ----
Location FR00
HIGH
FR01
HIGH
FR02
HIGH
FR10 FR11 FR12
HIGH HIGH HIGH
Location FF00
FF01
FF02
HIGH
FF11 FF12
HIGH HIGH
ALARM HIGH
-----------------------------------------------------------------------------
(8Way)
---- MAIN Chassis FANs ----------------------------- 19:20:57,01/31/2005 ----
(c)
Location FR0
low
FF0
low
-----------------------------------------------------------------------------
(ISPF)
---- MAIN Chassis FANs ----------------------------- 19:20:57,01/31/2005 ----
Location FR0
low
FR1
low
FF0
low
-----------------------------------------------------------------------------
Next page? (n[ext]/e[xit]/CR=next) : <ENTER>
(d)
(The numbers of CELL and XBX cards depend on 32Way/8Way and ISPF models.)
---- Power state of CELL cards and PROCs ----------- 19:20:57,01/31/2005 ----
PROC state
state
ON
x0 x1 x2 x3
ON ON OFF ---
--- --- --- ---
ON ON OFF OFF
--- --- ON ON
--- --- ON ON
--- --- ON ON
ON ON --- ---
--- --- --- ---
CELL0
CELL1
CELL2
CELL3
CELL4
CELL5
CELL6
CELL7
OFF
ON
OFF
ON
ON
ON
(e)
---
(The following information will be missing for 8Way:)
---- XBX card power state -------------------------- 19:20:57,01/31/2005 ----
state
XBX_C0
* XBX_C1
XBX_C2
ON
ON
OFF
---
XBX_C3
-----------------------------------------------------------------------------
Previous/Next page? (p[revious]/n[ext]/e[xit]/CR=next) : <ENTER>
(The numbers of PCI Bays to be shown depend on 32Way/8Way and ISPF models.)
---- PCIBAY power state/FAN alarm ------------------ 19:20:57,01/31/2005 ----
state
FANs
COREM/HDDM PCIM
PCIBAY0(D) ON
PCIBAY1(D) ---
* PCIBAY2(D) ON
PCIBAY3(D) OFF
PCIBAY4(D) ON
---
---
ALARM
(f)
PCIBAY5(D) ON
PCIBAY6(E) 未定
PCIBAY7(E) 未定
-----------------------------------------------------------------------------
2-39
855-900549
Download from Www.Somanuals.com. All Manuals Search And Download.
Base Module
Previous/Next page? (p[revious]/n[ext]/e[xit]/CR=next) : <ENTER>
(The total number of pages and page numbers depend on 32Way/8Way and ISPF models.)
---- Temperature (Celsius) [1/7] ------------------- 19:20:57,01/31/2005 ----
current
threshold
comment
FAN
IPMI ACPI S.D.
CELL0
PROC00
46
50
82
24
-
-
55
89
89
89
-
57
91
91
91
-
65
120
120
120
-
77/ 80
* PROC01
PROC02
PROC03
CELL1
77/ 80
FAN High-speed
77/ 80
(g)
-
24
-
-
-
55
-
57
-
65
PROC10
PROC11
PROC12
PROC13
-
-
-
-
-
-
24
24
77/ 80
77/ 80
89
89
91
91
120
120
-----------------------------------------------------------------------------
Previous/Next page? (p[revious]/n[ext]/e[xit]/CR=next) : <ENTER>
---- Temperature (Celsius) [2/7] ------------------- 19:20:57,01/31/2005 ----
current
threshold
comment
FAN
IPMI ACPI S.D.
CELL2
PROC20
46
50
82
24
24
26
27
27
27
27
-
55
89
89
89
89
55
89
89
89
89
57
91
91
91
91
57
91
91
91
91
65
120
120
120
120
65
77/ 80
77/ 80
77/ 80
77/ 80
-
* PROC21
PROC22
FAN High-speed
PROC23
(g)
* CELL3
PROC30
77/ 80
77/ 80
77/ 80
77/ 80
120
120
120
120
PROC31
PROC32
PROC33
-----------------------------------------------------------------------------
Previous/Next page? (p[revious]/n[ext]/e[xit]/CR=next) : <ENTER>
---- Temperature (Celsius) [3/7] ------------------- 19:20:57,01/31/2005 ----
current
threshold
comment
FAN
IPMI ACPI S.D.
CELL4
PROC40
46
50
82
-
-
55
89
89
-
57
91
91
-
65
120
120
-
77/ 80
* PROC41
PROC42
77/ 80
FAN High-speed
-
PROC43
* CELL5
PROC50
-
-
-
-
-
(g)
52
-
-
-
55
-
57
-
65
-
PROC51
PROC52
-
-
-
-
-
70
103
77/ 80
77/ 80
89
89
91
91
120
120
* PROC53
reported to the software
-----------------------------------------------------------------------------
Previous/Next page? (p[revious]/n[ext]/e[xit]/CR=next) : <ENTER>
855-900549
2-40
Download from Www.Somanuals.com. All Manuals Search And Download.
Base Module
---- Temperature (Celsius) [4/7] ------------------- 19:20:57,01/31/2005 ----
current
threshold
comment
FAN
IPMI ACPI S.D.
CELL6
PROC60
46
50
82
-
-
55
89
89
-
57
91
91
-
65
120
120
-
77/ 80
* PROC61
PROC62
PROC63
CELL7
77/ 80
FAN High-speed
-
-
-
-
-
-
-
-
-
-
-
(g)
-
-
-
-
PROC70
PROC71
PROC72
PROC73
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-----------------------------------------------------------------------------
Previous/Next page? (p[revious]/n[ext]/e[xit]/CR=next) : <ENTER>
(The numbers of XBX and Cx cards are changed on 32Way/8Way and ISPF.)
---- Temperature (Celsius) [5/7] ------------------- 19:20:57,01/31/2005 ----
current
threshold
comment
FAN
-
IPMI ACPI S.D.
XBX_C0
* XBX_C1
XBX_C2
52
61
24
-
55
55
55
-
57
57
57
-
65
65
65
-
-
reported to the software
-
(g)
XBX_C3
-
FAN
WARN
37
S.D.
40
* AIR FLOW IN
23
23/ 25
FAN High-speed
-----------------------------------------------------------------------------
Previous/Next page? (p[revious]/n[ext]/e[xit]/CR=next) : <ENTER>
(The numbers of PCI Bay cards are changed on 32Way/8Way and ISPF.)
---- Temperature (Celsius) [6/7] ------------------- 19:20:57,01/31/2005 ----
current
threshold
comment
PCI-
FAN
-
IPMI ACPI S.D.
BAY0(D) A
-B
45
45
52
-
55
55
55
-
57
57
57
-
65
65
65
-
-
IOX_C
-
BAY1(D) -A
-B
-
-
-
-
-
-
(g)
IOX_C
-
-
-
-
-
BAY2(D) -A
-B
IOX_C
45
45
63
45
45
52
-
55
55
55
55
55
55
57
57
57
57
57
57
65
65
65
65
65
65
-
-
reported to the software
BAY3(D) -A
-B
-
-
IOX_C
-
-----------------------------------------------------------------------------
Previous/Next page? (p[revious]/n[ext]/e[xit]/CR=next) : <ENTER>
2-41
855-900549
Download from Www.Somanuals.com. All Manuals Search And Download.
Base Module
(The numbers of PCI Bay cards are changed on 32Way/8Way and ISPF.)
---- Temperature (Celsius) [7/7] ------------------- 19:20:57,01/31/2005 ----
current
threshold
comment
PCI-
FAN
-
IPMI ACPI S.D.
BAY4(D) -A
-B
45
45
52
*
55
55
55
55
55
55
55
55
55
55
55
55
57
57
57
57
57
57
57
57
57
57
57
57
65
65
65
65
65
65
-
IOX_C
-
BAY5(D) -A
-B
-
45
52
45
45
52
45
45
52
-
(g)
IOX_C
-
BAY6(E) -A
-B
-
65 (tentative)
65 (tentative)
65 (tentative)
65 (tentative)
65 (tentative)
65 (tentative)
-
IOX_C
-
BAY7(E) -A
-B
-
-
IOX_C
-
-----------------------------------------------------------------------------
Previous page? (p[revious]/e[xit]/CR=back) : <ENTER>
select display mode? (i[nteractive per page]/a[ll]/CR=exit) : <ENTER>
EN command terminated.
855-900549
2-42
Download from Www.Somanuals.com. All Manuals Search And Download.
Base Module
(Description)
Description
No.
Description
Allows to choose environmental data formats from page format of 24 lines each
or online format.
(a)
Indicates the states of the Power Bay within the cabinet.
If an alarm condition exists, this line is prefixed with an asterisk (*).
state
ON
OFF
---
: A DC power (48V) is applied to the components inside the cabinets.
: No DC power (48V) is applied to the components inside the cabinets.
: The Power Bay itself is not existent (not visible from the iSP).
(b)
DPSx
(blank) : Indicates the normal state.
ALARM : Indicates an alarm state.
---
: Indicates that the DPS is not existent (not visible from the iSP).
NORESP : Indicates that the DPS is existent but not visible from the iSP.
No DPS exists on a 48-VDC supply.
Shows the states of the fans located in the CPU cage or main chassis in the
Main Cabinet.
If an alarm condition exists, this line is prefixed with an asterisk (*).
---
: Indicates that no fan exists.
(c)
ALARM : Indicates an alarm state.
low
: Indicates that the fan is running at low speed.
HIGH
: Indicates that the fan is running at high speed. “HIGH” will appear if
any cause of high-speed fan exists even when the system is in Halt.
(d)
(e)
Press <ENTER> to go to the next page.
Power On/Off state of the CELL and XBX Cards in the CPU cage or main chassis
within the Main Cabinet.
Power and fan states within the PCI Bay.
(f)
If a fan alarm exists, this line is prefixed with an asterisk (*)
PCI Bay types (D) and (E) are added for PCID Bay and PCIE Bay, respectively.
Temperature detected by the card’s temperature sensor is shown here. If a
temperature sensor failure exists, an asterisk (*) is shown in place of a
temperature readout.
If a temperature alarm exists, the pertinent line is prefixed with an asterisk (*)
The threshold information hardwire-coded in the iSPFW is also shown here.
“FAN” gives the temperature thresholds where fan speed is switched from low to
high and vice versa.
The values on the right side give the threshold to switch from low to high speed,
and those on the left side from high to low speed.
“IPMI” gives the threshold over which temperature information is reported to the
software through the IPMI interface.
(g)
“ACPI” gives the threshold over which temperature information is reported to the
software through the ACPI interface.
“S.D.” specifies the temperature threshold for the SPFW to force system shut
down. If AIR FLOW IN (intake temperature) reaches the S.D. theshold, all the
running partitions are forcibly shut down.
The WARN column on AIR FLOW IN (intake temperature) gives the threshold
rejecting to boot currently inactive partitions.
2-43
855-900549
Download from Www.Somanuals.com. All Manuals Search And Download.
Base Module
2.4.6.6. FV (Firmware Versions)
m
X
b
X
u
X
* Always valid without regard to the current system status.
Function:
This command is used to show version information for the iSPFW and BIOS.
This command also provides checksum test on the FW storage areas.
Note that, in a duplicated iSP environment, information is managed separately for each of the
duplicated iSPs.
Also the display information may slightly change from one SPFW version to another.
(Screen Example)
Description
No.
iSPyz:---> fv<ENTER>
Firmware Versions : (currently running firmware is Rxx.xx)
iSP BOOT
(*)
: xx.xx generated on mm/dd/yyyy hh:mm:ss
: xx.xx generated on mm/dd/yyyy hh:mm:ss
) : xx.xx generated on mm/dd/yyyy hh:mm:ss
iSP FW bank (*)
BIOS bank0 (012
(a)
(b)
BIOS bank1 ( 345 ) : xx.xx generated on mm/dd/yyyy hh:mm:ss
BIOS bank2 ( 67) : xx.xx generated on mm/dd/yyyy hh:mm:ss
Do you want to check the flash memory? (y/[n]) : y<ENTER>
checking iSP BOOT bank...
passed.
checking iSP FW bank...
passed.
checking BIOS bank0...
passed.
(c)
checking BIOS bank1...
passed.
checking BIOS bank2...
passed.
FV command terminated.
(Description)
Description
Description
No.
(a)
(b)
(c)
Lists the current states of the FW storage areas.
If a checksum test on the FW storage area is needed, enter “y.”
Lists the results of checksum test.
855-900549
2-44
Download from Www.Somanuals.com. All Manuals Search And Download.
Base Module
2.4.6.7. HC (Hardware Configuration)
m
X
b
u
* For system states and subcommand validity, read the description of subcommands.
Function:
This command is used to show the hardware configuration and enable to change it.
It is also used to configure, show, or change partitions.
In a duplicated iSP environment, the hardware configuration is automatically matched between
the duplicated iSPs.
Description of Subcommands
cmd
arg1
arg2
arg3
arg4
Description
help
-
-
-
-
-
-
-
-
Show a list of subcommands.
This subcommand is always valid without
regard to the current system state.
Quit the HC command.
quit
exit
Before the HC command quits, the check
subcommand is automatically run.
These subcommands are always valid
without regard to the current system state.
Show the system’s hardware configuration.
If no argument is specified or has an error,
the disp subcommand help opens.
This subcommand is always valid without
regard to the current system state.
Argument “all” shows all the configuration
information.
disp
-
-
-
-
all
-
-
-
-
-
-
part
Show the current partitioning.
The following information is given for each
partition:
State summary
Physical CELL No. and logical CELL No.
Physical IOX No. and logical IOX No.
Size of shared memory (ISPF only)
Show the Main Cabinet or Main Chassis
configuration.
main
-
-
-
For the 8Way/ISPF model, the configurations
of external PCI Bay and Power Bay are also
shown.
exp
-
-
-
-
-
-
Valid only for the 32Way model.
Use this argument to show the expansion
cabinet configuration.
cellx
Show the CELL configuration.
X denotes a physical CELL number (0-7).
2-45
855-900549
Download from Www.Somanuals.com. All Manuals Search And Download.
Base Module
cmd
arg1
arg2
arg3
arg4
Description
mmxxy
-
-
-
-
-
-
Show the detailed configuration of the ROW
under the MMX specified by xy, and in the
case of the 32Way(H) model, show detailed
configuration of the DIR.
x is the physical CELL number where the
MMX is installed (0-7).
y is the MMX number within the CELL (0-3).
Show the detailed configuration of the TAG
for the 32Way(B)/8Way/ISPF models. This
argument is invalid for the 32Way(H) model.
x is the physical CELL number where the
TAG is installed (0-7).
tagxs
s is either ’e’ (EVEN side) or ’o’ (ODD side).
Show the XBX Card configuration and XBX
LSI configuration on that card.
x is a physical XBX Card number (0-3).
Show the XBX configuration.
xbxcx
-
-
-
-
-
-
xbxxy
x is an XBX Card number (0-3).
y specifies an XBX number on the XBX Card
(0-1).
pcibx
ioxx
-
-
-
-
-
-
Show the PCI Bay (IOX) configuration.
x is the DGI/I2C cable port number (0-7) that
connects iSP to PCI Bay.
Show the configurations and information of
the PCI Cards that are under the PXH within
the PCI Bay.
pcix
x is the DGI/I2C cable port number (0-7) that
connects iSP to PCI Bay.
cpcix
pbayx
-
-
-
-
-
-
Show the configurations and information of
the PCI Cards on the Core Card within the
PCI Bay.
x is the DGI/I2C cable port number (0-7) that
connects iSP to PCI Bay.
Show the Power Bay configuration.
x is a Power Bay number. The allowable
range of x is as follows:
For 32Way:
0, 1: Power Bay numbers within the Main
Cabinet
2, 3: Power Bay numbers within the
Expansion Cabinet
For 8Way:
0: Power Bay No. inside the chassis
1: Power Bay No. outside the chassis
For ISPF:
0: Power Bay No. inside the chassis
attach
-
-
-
-
Use this command to attach partition
numbers to CELL or IOX Cards.
If no argument is specified or an argument
has an error, the attach command help
opens.
This command is not valid while the partition
is booting up, shutting down, or handling an
error.
855-900549
2-46
Download from Www.Somanuals.com. All Manuals Search And Download.
Base Module
cmd
arg1
cellx
arg2
arg3
m
arg4
Description
n
-
Attach the CELL Card having physical CELL
number x to partition number n, using logical
CELL number m (which is visible to the
software or BIOS).
This command may also be used to change
a logical CELL number for an already
attached CELL.
A logical CELL number must be unique to
every 8 CELL Cards.
The logical CELL number of an online CELL
Card is unable to be altered.
ioxx
n
m
[p|s]
Attach the IOX Card having physical IOX
number x to partition number n, using logical
IOX number m (which is visible to the
software or BIOS).
Specify p for arg4 if the PCI Bay with BIO is
to use that BIO. Specify s for arg4 if the PCI
Bay having duplicated BIOs is to use the
secondary BIO.
This command may also be used to change
a logical IOX number for an already attached
IOX.
A logical IOX number must be unique within
a partition.
The logical IOX number of an online IOX
Card cannot be altered.
detach
-
-
-
-
Use this command to detach partition
numbers from CELL or IOX Cards.
If no argument is specified or an argument
has an error, the detach command help
opens.
Online components are unable to be
detached.
It is not allowed to detach components either
when the partition is booting up, shutting
down, or handing an error.
cellx
ioxx
-
-
-
-
-
-
-
-
-
Detach the CELL Card with physical CELL
number x from the partition to which it is
currently attached.
Detach the IOX Card with physical IOX
number x from the partition to which it is
currently attached.
Detach all the CELL and IOX Cards from the
partitions to which they are currently
attached.
partx
x: Partition number
2-47
855-900549
Download from Www.Somanuals.com. All Manuals Search And Download.
Base Module
cmd
arg1
arg2
arg3
arg4
Description
swap
-
-
-
-
This command is currently not supported.
This command can be used to swap a CELL
with another CELL while the software is
running (it is not a combination of
attach/detach commands, but provides a
function exclusive to this command).
If no argument is specified or an argument
has an error, the swap command help opens.
While this command is valid to running
partitions, it is only functional when it is used
with the OS that supports online
attach/detach capability.
This command is supported on the 32Way(B)
and 8Way models.
cellx
celly
-
-
Swap a running CELL having physical CELL
number x with another CELL having physical
CELL number y.
CELLy must be the one that is not attached
to any partition.
For CELL swapping, an invalid partition is
needed to which no CELLs or IOXs belong.
When swapping is complete, CELLx is
detached from the partition, while CELLy is
attached to it.
Logical CELL number is transferred from
CELLx to CELLy.
smem
-
-
-
-
This command is only supported on the ISPF
model. It is not supported on any other
models.
Use this command to set the size of the
memory area shared by partitions.
If no argument is specified or an argument
has an error, the smem command help
opens.
This command is valid to partitions that are
not running.
n
mmm
-
-
-
-
Set the shared memory size for the partition
with partition number n, in a GB increment.
It is not allowed to change the shared
memory size for active partitions.
No shared memory is used if 0 is specified.
This command is only supported on the
32Way(B) model. It is not supported on any
other models.
cmem
-
-
Use this command to set the size of the
memory used for inter-CELL interleaving. If
no argument is specified or an argument has
an error, the cmem command help opens.
This command is valid to inactive partitions.
Set the memory size for inter-CELL
interleaving for partition number n, in a GB
increment.
n
mmm
-
-
No interleaving is used if 0 is specified.
Numbers that are not multiples of 16 GB will
be rounded to multiples of 16 GB.
855-900549
2-48
Download from Www.Somanuals.com. All Manuals Search And Download.
Base Module
cmd
add
arg1
arg2
arg3
arg4
Description
-
-
-
-
Use this command to manually inform the
iSP of an addition of components. iSP’s
management state will change from
“nonexist.” to “power-off.”
If no argument is specified or an argument
has an error, the add command help opens.
This command is always valid without regard
to the current system state (with the
exception of the PBAY, to which this
command is valid only if none of the
partitions is active).
This command is not valid to the CELL
Cards, XBX Cards, PCI Bay, or their
subcomponents if any of the partitions within
the system is booting up, shutting down, or
handling an error.
pbayx
-
-
-
Add Power Bays.
x is a Power Bay number. The allowable
value of x is as follows:
For 32Way:
0, 1: Power Bay No. in the Main Cabinet
2, 3: Power Bay No. in the Expansion
Cabinet
For 8Way:
0: Power Bay No. inside the chassis
1: Power Bay No. outside the chassis
For ISPF:
0: Power Bay No. inside the chassis
dpsxy
ispx
-
-
-
-
-
-
-
-
-
Add DPS’s to Power Bays.
The meaning of x is identical to that for
argument pbay.
y is a DPS No. within a Power Bay (0-5).
Add backup iSPs.
x is the physical number of an iSP (0 or 1).
Backup iSPs can only be added to the
32Way model.
clkx
Add CLK Cards.
x is the physical number of the CLK Card (0
or 1).
The CLK Card can only be added to the
32Way model.
xbxcx
-
-
-
Add XBX Cards.
x is an XBX Card number (0-3).
The SP will automatically recognize the
number of XBX LSI chips installed on the
XBX Card.
cellx
-
-
-
-
-
-
Add CELL Cards.
x is the physical number of the CELL Card
(0-7).
procxy
Add processors.
x is the physical number of the CELL Card
(0-7).
y is the location of the processor on the
CELL Card (0-3).
2-49
855-900549
Download from Www.Somanuals.com. All Manuals Search And Download.
Base Module
cmd
arg1
memdx
arg2
arg3
arg4
Description
This command is only valid to the 32Way
model.
Use it to add MMX (2-3) and ROW to the
memory daughter card. The DIMM capacity
is automatically read when it is being
initialized.
x is the physical number of the CELL Card
(0-7).
Add PCI Bays.
-
-
-
-
pcibx
d|e
[core]
x is a DGI/I2C port number on the iSP side
(0-7).
Use arg2 to specify the type of the PCI Bay
(mandatory). Specify “d” for PCID-Bays, and
“e” for PCIE-Bays.
Specify “core” for arg3 if Core Cards (GXB)
are installed.
If the type of the PCI Bay (PCID/PCIE) or the
presence of the Core Card has been
changed, the SP will know that change from
the revision information for that PCI Bay.
delete
-
-
-
-
Use this command to delete components
from iSP management. If physically removed
components are left under iSP management,
they will be handled as an “INVISIBLE” error
indefinitely.
If no argument is specified or an argument
has an error, the delete command help
opens.
Components in DC-ON state are unable to
be deleted (with the exception of the CLK
and DPS).
The CELL Card, XBX Card, PCI Bay, or their
subcomponents is unable to be deleted if
any of the partitions within the system is
booting up, shutting down, or handling an
error.
<arg1>
-
-
-
-
-
-
<arg1> is identical to that for the add
command.
Use this command to enable the
enable
-
components that are currently “DISABLED.”
If no argument is specified or an argument
has an error, the enable command help
opens.
This command is valid only if the partition to
which the pertinent components belong is
not active.
The CELL Card, XBX Card, PCIX, and their
subcomponents can be enabled unless any
of the partitions within the system is booting
up, shutting down, or handling an error.
The Power Bay can be enabled only if none
of the partitions within the system is active.
855-900549
2-50
Download from Www.Somanuals.com. All Manuals Search And Download.
Base Module
cmd
arg1
pbayx
arg2
arg3
arg4
Description
Enable the Power Bay.
-
-
-
x is a Power Bay number. The allowable
value of x is as follows:
For 32Way:
0, 1: Power Bay numbers within the Main
Cabinet
2, 3: Power Bay numbers within the
Expansion Cabinet
For 8Way:
0: Power Bay number inside the chassis
1: Power Bay number outside the chassis
For ISPF:
0: Power Bay number inside the chassis
clkx
-
-
-
-
-
Enable the CLK.
x is a CLK number (0 or 1).
The CLK is installed only in the 32Way
model.
xbxcx
[all]
[all]
Enable the XBX Card.
x is an XBX Card number (0-3).
If arg2 is omitted, only the XBX Card is
enabled, with its subcomponents left
disabled.
If “all” is specified for arg2, XBX Card is
enabled including all of its subcomponents.
Enable the XBX LSI.
xbxxy
-
-
x is an XBX Card number (0-3).
y is an XBX LSI number (0-1) on an XBX
Card.
If arg2 is omitted, only the XBX Card is
enabled, with its subcomponents left
disabled.
If “all” is specified for arg2, the XBX Card is
enabled including all of its subcomponents.
cellx
[all]
-
-
Enable the CELL Card.
x is a physical CELL number (0-7).
If arg2 is omitted, only the CELL Card is
enabled, with its subcomponents left
disabled. In this case, console operation will
be rejected if essential components are
disabled.
If “all” is specified for arg2, the CELL Card is
enabled including all of its subcomponents.
cnxxy
-
-
-
-
-
-
-
-
Enable the CNX LSI.
x is a physical CELL number (0-7).
y is a CNX number (0-1) within a CELL.
CNX1 exists only in the 32Way(H) model.
Enable the Processor.
x is a physical CELL number (0-7).
y is a Processor number (0-3) within the
CELL.
procxy
mmxxy [all]
Enable the MMX.
x is a physical CELL number (0-7).
y is an MMX number (0-3) within the CELL.
If arg2 is omitted, only the MMX is enabled,
with its subcomponents left disabled.
If “all” is specified for arg2, the MMX is
enabled including all of its subcomponents.
2-51
855-900549
Download from Www.Somanuals.com. All Manuals Search And Download.
Base Module
cmd
arg1
rowxzz
arg2
arg3
arg4
Description
Enable the ROW.
-
-
-
-
-
-
x is a physical CELL number (0-7).
zz is a ROW number (00-15), which must
always be specified with a 2-digit number.
For the 32Way(H) model, the corresponding
Directory memory is also enabled.
There is no individual DIMM control. The
DIMM is automatically detected on boot-up.
For the 32Way(H) model, use this argument
to enable the Directory memory and the
corresponding ROW memory.
dirxzz
This command is invalid to the
32Way/8Way/ISPF models.
x is a physical CELL number (0-7).
zz is a Directory number (00-15), which must
always be specified with a 2-digit number.
There is no individual DIMM control. The
DIMM is automatically detected on boot-up.
Enable the TAG for 32Way(B)/8Way/ISPF
models.
tagx[sy
z]
-
-
-
x is a physical CELL number (0-7).
s should be either ‘e’ (EVEN side) or ‘o’
(ODD side).
y is a TAG Bank number (0-1).
z is a TAG Bank level number (0-5).
If s, y, and z are all omitted, all the TAGs
under the CELL Card specified by x are
enabled.
pcibx
[all]
[all]
-
-
-
-
Enable the PCI Bay.
x is the DGI/I2C cable port number (0-7) that
connects iSP to PCI Bay.
Always specify “all” for arg2, so that all the
subcomponents including the PCI Bay itself
are enabled.
ioxx
Enable the IOX.
x is a physical IOX number (0-7).
If arg2 is omitted, only the IOX is enabled,
with its subcomponents left disabled.
If “all” is specified for arg2, the IOX Card is
enabled including all of its subcomponents.
iocy
-
-
-
-
Enable the IOC.
y is an IOC number (0 or 1) within an IOX.
Enable the GXB on the Core IO Card.
x is the DGI/I2C cable port number (0-7) that
connects iSP to PCI Bay.
gxbxy
-
y is a GXB number (0).
cpcixy
-
-
-
-
-
-
Enable the slots (1-2) on the Core IO Card.
x is a PCI Bay number (0-7).
y is a slot number (1-2).
pxhxy
Enable the PXH.
x is the DGI/I2C cable port number (0-7) that
connects iSP to PCI Bay.
y is a PXH number (0-3).
pcix0y
-
-
-
Enable the slots (1-8) on the PXH.
x is a PCI Bay number (0-7).
y is a slot number (1-8).
855-900549
2-52
Download from Www.Somanuals.com. All Manuals Search And Download.
Base Module
cmd
arg1
arg2
arg3
arg4
Description
disable
-
-
-
-
Use this command to manually “DISABLE”
the components that are currently enabled.
If no argument is specified or an argument
has an error, the disable command help
opens.
Online components are unable to be
disabled.
It is not allowed to disable the CELL Card,
XBX Card, PCI Bay, and their
subcomponents when any of the partitions
within the system is booting up, shutting
down, or handling an error.
<arg1> <arg2>
-
-
-
-
<arg1> and <arg2> are the same as those
for the enable command.
Argument “all” is not allowed for this
command.
This command is currently not supported.
This command can be used to dynamically
connect currently offline components (CELL,
XBX Card, and PCI Bay) to the system while
the OS is running. It remains invalid while
any of the partitions within the system is
booting up, shutting down, or handling an
error.
online
-
-
The CELL and PCI Bay are functional only if
they are used in online conjunction with the
OS that supports this command function.
If no argument is specified or an argument
has an error, the online command help
opens.
This command is supported on the
32Way(B), 8Way, and ISPF models. It is not
supported on the 32Way(H) model.
Connect CELL Cards to the partition to which
they belong.
A vacant partition to which no CELL or IOX
belongs is needed.
This command is supported on the 32Way(B)
and 8Way models.
Connect XBX Cards to the system.
On the 32Way(B) model, XBX Cards need
be connected to the system in pairs: i.e. XBX
Cards 0 and 2 or 1 and 3. A single XBX Card
alone is not accepted.
cellx
-
-
-
-
-
-
xbxcx
The XBX Card is not connectable to the
8Way model.
xbxc0
portx
Connect inter-XBX external interface ports to
the system, to which cabinets are connected.
x: XBX port number (4-5)
This command is supported on the ISPF
system. It is valid when the operating
systems are running (ACPI S0 State) on both
systems.
2-53
855-900549
Download from Www.Somanuals.com. All Manuals Search And Download.
Base Module
cmd
arg1
pcibx
arg2
arg3
arg4
Description
Connect PCI Bays to the partitions to which
they belong.
x: Physical PCI Bay number (0-7)
This command is supported on the 32Way(B)
model.
This command is currently not supported.
This command can be used to dynamically
disconnect currently online components
(CELL, XBX Card, and PCI Bay) from the
system while the OS is running.
-
-
-
-
-
-
offline
-
If this command attempts to disrupt the
current system operation, it will be rejected.
This command remains invalid while any of
the partitions within the system is booting up,
shutting down, or handling an error.
The CELL and PCI Bay are functional only if
they are used in conjunction with the OS that
supports this command.
If no argument is specified or an argument
has an error, the offline command help
opens.
This command is supported on the
32Way(B), 8Way, and ISPF models. It is not
supported on the 32Way(H) model.
cellx
-
-
-
-
-
-
Disconnect the CELL Cards from the system
and shut off their power. The CELL that
controls the Compatibility PCI is unable to be
disconnected.
The ISPF is not the target of this command.
xbxcx
Disconnect the XBX Cards from the system.
On the 32Way(B) model, they must always
be disconnected in pairs: i.e. XBX Cards 0
and 2 or 1 and 3. It is not allowed to
disconnect a single XBX Card alone.
The XBX Cards are unable to be
disconnected on the 8Way model.
Disconnect the inter-XBX external interface
that connects cabinets.
xbxc0
pcibx
-
portx
x: XBX port number (4-5)
This command is supported on the ISPF
System on which the OS is running (ACPI S0
State).
Disconnect the PCI Bay from the system and
shut off its power. It is not allowed to
disconnect the PCI Bay that contains the
Compatibility PCI.
-
-
-
-
-
-
This command is supported on the 32Way(B)
model.
led
Use this command to turn on/off the LEDs
used for device location checkout.
If no argument is specified or an argument
has an error, the led command help opens.
This command is always valid to the CLK,
XBX, and CELL Cards along with the PCI
Bay regardless of the current system state.
It is valid to the PCI slot only if the host GXB
or PXH is online.
855-900549
2-54
Download from Www.Somanuals.com. All Manuals Search And Download.
Base Module
cmd
arg1
clkx
arg2
on|off
arg3
arg4
Description
Turn On/Off the LED on the CLK Card.
x is a CLK Card number (0-1).
Turn On/Off the LED on the XBX Card.
x is a XBX Card number (0-3).
Turn On/Off the LED on the CELL Card.
x is a physical CELL number (0-7).
Turn On/Off the LED on the PCI Bay.
x is a PCI Bay number (0-7).
-
-
-
-
-
-
-
-
-
-
xbxcx
cellx
on|off
on|off
on|off
pcibx
pcix0y on|off
Turn On/Off the LEDs on the PCI Bay’s PXH
PCI slots by specifying the slot numbers
printed on the back of the box.
x is a PCI Bay number (0-7).
y is a slot number (PXH slot number (1-8)
printed on the back of the box).
frn
ffn
-
on|off
-
-
-
-
Turn On/Off the Fan-Box LEDs by specifying
their locations.
Argument frn specifies the rear-side
Fan-Box, and ffn the front-side Fan-Box.
loc
-
This command is supported on the 8Way
and ISPF models.
Use this command to manually specify
devices’ location information.
If no argument is specified or an argument
has an error, the loc command help opens.
This command is valid only if all the
partitions are inactive.
main
d
d
This command is supported on the 8Way
and ISPF models.
It sets the vertical position of the main
chassis within the cabinet.
Argument d specifies the position (U) of the
bottom of the main chassis with a decimal
number (0-40).
The default value is null (0).
pbayx
h
-
Set the vertical position and height of Power
Bay No.1 that is installed outside the main
chassis of the 8Way model.
x is only valid if it specifies Power Bay No.1.
Argument d specifies the position (U) of the
bottom of the unit with a decimal number
(0-40).
Argument h specifies the height of the unit
(2).
This command is not supported on the
32Way, ISPF, or Power Bay No. 0 for the
8Way model as the Power Bay position and
height are uniquely determined on those
models.
2-55
855-900549
Download from Www.Somanuals.com. All Manuals Search And Download.
Base Module
cmd
check
arg1
arg2
arg3
arg4
Description
-
-
-
-
This command is used to check the current
system configuration focusing on the
following points:
• Presence of units with unspecified
locations
• Presence of DISABLED components
• Presence of INVISIBLE units
This command is always valid without regard
to the current system state.
The “DISABLE.” components are not the
target of this command.
clear
rowxyy
|
dirxzz
-
-
-
Use this command to clear the ROW or
Directory memory bit error counters.
x is a physical CELL number (0-7).
yy is a ROW number (00-15) within a CELL,
which must be specified with a 2-digit
number.
zz is a Directory number (00-15) within a
CELL, which must be specified with a 2-digit
number.
This command clears the 3 counters - the
single-bit error counter that counts errors for
every DIMM and the multibit error counter
that counts errors for every ROW - at a time,
along with the page deallocation entry table.
Argument dirxzz is only supported on the
32Way(H) model.
This command is always valid without regard
to the current system state.
bio
ioxy
[ioxz]
-
-
Use this command to specify the BIO to be
used on the IOX (PCI Bay) that is attached to
a partition.
For partitions with duplicated BIOs, use
<arg2> to specify the IOX (PCI Bay) with a
secondary BIO. If <arg2> is omitted, the
secondary BIO is regarded to be
non-existent.
The IOX (PCI Bay) specified in this
command must be attached to a partition.
This command is valid only if the partition is
inactive.
It is not supported on the ISPF.
scsi_sp pcibx
lit
on|off
-
-
Use this command to specify the SCSI split
mode (split mode ON or OFF) for PCI Bay
No. x.
Split mode is set to OFF by default.
Split mode setting can be changed when the
partition to which the pertinent PCI Bay
belongs is inactive or the power to the PCI
Bay is left off. Split mode setting cannot be
changed while the partition is booting up or
shutting down.
855-900549
2-56
Download from Www.Somanuals.com. All Manuals Search And Download.
Base Module
Description of Status Indicator Strings
Indicator
string
Description
nonexist.
Indicates that a resource is defined to be non-existent (the iSP does not
assume that it “should” be existent).
INVISIBLE
The iSP assumes that the resource “should” be existent, but actually the
resource is not visible to the iSP due to a failure or removal of a card.
Once a resource is visible to the iSP (whether it is automatically detected or
manually configured), it is subsequently assumed to be “existent” unless it is
explicitly deleted with the delete command.
power-off
power-ON
Indicates that the DC power is Off.
On some components, the DC power is activated immediately when the AC
power is applied.
Indicates that the DC power is On.
On some components, this indicator may be overwritten with any of the
following indicators.
offline
Indicates that the component’s DC power is On but it is not connected to the
system as viewed from the software (OS or BIOS).
ONLINE
MASTER
Indicates that the component’s DC power is On and it is connected to the
system as viewed from the software (OS or BIOS).
This indicator is only valid for iSP/CLK status display. It indicates that the
component is assigned as the master.
When the CLK is assigned as the master, it means that it supplies the CELL
and XBX Cards with the clocks.
backup
This indicator is only valid for iSP/CLK status display. It indicates that the
component is assigned as backup.
The CLK, if assigned as backup, is supplying the CELL or XBX Cards with no
clocks. The backup indicator is active when the system is in Halt mode.
enable
enable-
Indicates that the component itself is valid (used for system operation).
Indicates that the component itself is valid but is reserved by software, etc. so
it will not be used for system operation on a next boot.
enable*
Indicates that the component is invalid on a next shut-down due to
component’s own failure.
DISABLE
DISABLE*
Indicates that the component itself is invalid (not used for system operation).
The component is manually disconnected with the disable command.
Indicates that the component itself is invalid (not used for system operation).
The component is disconnected due to component’s own failure.
It should not be connected to the system until the failure is serviced.
Indicates that the component itself is made invalid by a software request, and
is to stay invalid on a next boot.
Indicates that the component itself is made invalid by a software request, and
is reversed to become valid on a next boot.
Indicates that the component is invalid because it cannot be made valid due to
its upper-level components or system configuration restrictions, but is reserved
to be made valid on a next boot.
DISABLE&
DISABLE+
DISABLE.
not used
DEG
Indicates an unused subcomponent.
Indicates that there are one or more subcomponents that are in DISABLE or
DISABLE. state.
RUN
INIT
Indicates that the partition (BIOS) is already booted.
Indicates that the partition is being booted.
FAIL
SHUT
DIAG
P-ON
stop
Indicates that the partition is in a fatal fault.
Indicates that the partition is being shut down.
Indicates that the partition is running an auxiliary CELL diagnosis.
Indicates that the partition is powered On for expanded diagnosis.
Indicates that the partition is inactive (DC power off).
2-57
855-900549
Download from Www.Somanuals.com. All Manuals Search And Download.
Base Module
(Screen Example … Help Screen)
Description
No.
iSPyz:---> hc<ENTER>
iSP FW version is Rxx.xx.
HC> help<ENTER>
HC command help :
(a)
help
disp
: print this message.
: display current status.
smem
: set size of shared memory of a partition.
: attach CELLs and IOXs to a partition.
: detach CELLs and IOXs from a partition.
: swap CELLs in a partition.
: add a component.
attach
detach
swap
add
delete
enable
disable
online
offline
led
: delete a component.
: enable a component.
(b)
: disable a component.
: make a component online.
: make a component offline.
: turn on/off maintenance LED of a component.
: set location info.
loc
clear
check
bio
: clear memory bit error counters.
: check illegal configuration.
: add and set a bio to a pcibay.
scsi_split : set/reset split mode of SCIS on PCIBAY
quit
: quit from HC command prompt.
(Description)
Description
Description
No.
(a)
(b)
If “help” is entered, the HC command help opens.
An HC command list appears.
(Screen Example … ALL Screen)
Description
No.
iSPyz:---> hc<ENTER>
iSP FW version is Rxx.xx.
HC> disp all<ENTER>
(32Way) The CIMB-CELL interleave memory size is only shown for the 32Way(B) model.
When operating in inter-CELL interleave mode, an asterisk “*” appears.
==== Partitioning ==================================== 19:20:23,07/31/2005 ===
part0(RUN ) CELL:01-----7 (01-----2) IOX:0-----67 (0-----12) CIMB: 32GB*
part1(INIT) CELL:--2----- (--5-----) IOX:-1------ (-0------) CIMB:128GB
part2(stop) CELL:---3---- (---4----) IOX:--2----- (--0-----) CIMB:-----
part3(stop) CELL:------6- (------3-) IOX:---3---- (---0----) CIMB:-----
part4(----) CELL:-------- (--------) IOX:-------- (--------) CIMB:-----
part5(----) CELL:-------- (--------) IOX:-------- (--------) CIMB:-----
part6(----) CELL:-------- (--------) IOX:-------- (--------) CIMB:-----
(a)
855-900549
2-58
Download from Www.Somanuals.com. All Manuals Search And Download.
Base Module
part7(----) CELL:-------- (--------) IOX:-------- (--------) CIMB:-----
==============================================================================
(8Way)
==== Partitioning ==================================== 19:20:23,07/31/2005 ===
part0(RUN ) CELL:01 (01) IOX:0- (0-)
part1(INIT) CELL:-- (--) IOX:-1 (-0)
==============================================================================
(ISPF)
==== Partitioning ==================================== 19:20:23,07/31/2005 ===
part0(RUN ) CELL:01 (01) IOX:0- (0-) SM: 4096MB
part1(INIT) CELL:-- (--) IOX:-1 (-0) SM: --------
==============================================================================
The SM size is shown for the ISPF.
(32Way)
==== Main cabinet ==================================== 19:20:23,07/31/2005 ===
POWBAY0 (loc=M-00/03)
POWBAY1 (loc=M-03/03)
power-ON enable
power-ON enable
DEG
DEG
---- CPU/Memory sub-chassis (loc=M-14/23) ------------ 19:20:23,07/31/2005 ---
iSP0 (loc=M-14/23)
iSP1 (loc=M-14/23)
CLK0 (loc=M-14/23)
CLK1 (loc=M-14/23)
XBX_C0(loc=M-14/23)
XBX_C1(loc=M-14/23)
XBX_C2(loc=M-14/23)
XBX_C3(loc=M-14/23)
CELL0 (loc=M-14/23)
CELL1 (loc=M-14/23)
CELL2 (loc=M-14/23)
CELL3 (loc=M-14/23)
CELL4 (loc=M-14/23)
CELL5 (loc=M-14/23)
CELL6 (loc=M-14/23)
CELL7 (loc=M-14/23)
MASTER
backup
MASTER
backup
offline
------- ---
------- ---
enable
---
DISABLE* ---
enable
power-off DISABLE
(b)
ONLINE
ONLINE
ONLINE
enable
enable
enable
DEG part.0 (LCN=0)
power-off DISABLE DEG part.0 (LCN=1)
ONLINE
enable
part.1 (LCN=5)
part.2 (LCN=4)
power-off enable
nonexist. -------
nonexist. -------
power-off DISABLE*
INVISIBLE -------
part.3 (LCN=3)
part.0 (LCN=2)
---- PCIBAYs (Main) ---------------------------------- 19:20:23,07/31/2005 ---
PCIBAY0(D) (loc=M-06/04) ONLINE
PCIBAY1(D) (loc=M-06/04) ONLINE
PCIBAY2(D) (loc=M-16/04) ONLINE
enable
enable
enable
DEG part.0 (LIN=2,-,S) *1
part.1 (LIN=0,-,N) *1
part.1 (LIN=1,P,N) *1
part.2 (LIN=0,-,S) *1
(c)
PCIBAY3(D) (loc=M-10/04) power-off enable
==== End of Main cabinet =====================================================
==== Expansion cabinet =============================== 19:20:23,07/31/2005 ===
POWBAY2 (loc=E-00/03)
POWBAY3 (loc=E-03/03)
power-ON enable
power-ON enable
(d)
(e)
---- PCIBAYs (Expansion) ------------------------------ 19:20:23,07/31/2005 ---
PCIBAY4(D) (loc=E-06/04) power-off enable
PCIBAY5(D) (loc=E-06/04) power-off enable
part.0 (LIN=0,-,N) *1
part.0 (LIN=0,-,N) *1
PCIBAY6(D) (loc=E-10/04) power-off DISABLE DEG part.0 (LIN=0,-,N) *1
PCIBAY7(D) (loc=E-10/04) ONLINE enable DEG part.0 (LIN=1,-,N) *1
==== End of Expansion cabinet =================================================
2-59
855-900549
Download from Www.Somanuals.com. All Manuals Search And Download.
Base Module
(8Way)
==== Summary (loc=M-00/08) =========================== 19:20:23,07/31/2005 ===
POWBAY0 (loc=M-00/08)
power-ON enable
iSP0 (loc=M-00/08)
CELL0 (loc=M-00/08)
CELL1 (loc=M-00/08)
MASTER
ONLINE
------- ---
enable
part.0 (LCN=0)
(b)
power-off DISABLE DEG part.0 (LCN=1)
PCIBAY0(D) (loc=M-00/08) ONLINE
PCIBAY1(D) (loc=M-00/08) ONLINE
enable
enable
part.0 (LIN=0,P,N) *1
part.0 (LIN=0,S,N) *1
==== End of Summary ==========================================================
(ISPF)
==== Summary (loc=M-00/10) =========================== 19:20:23,07/31/2005 ===
POWBAY0 (loc=M-00/10)
power-ON enable
iSP0 (loc=M-00/10)
XBX_C0(loc=M-00/10)
CELL0 (loc=M-00/10)
CELL1 (loc=M-00/10)
MASTER
------- ---
power-off enable
DEG
ONLINE
enable
part.0 (LCN=0)
power-off DISABLE DEG part.0 (LCN=1)
(b)
PCIBAY0(D) (loc=M-00/10) ONLINE
PCIBAY1(D) (loc=M-00/10) ONLINE
enable
enable
part.0 (LIN=0,P,N) *1
part.0 (LIN=0,-.N) *1
==== End of Summary ==========================================================
*1 (LIN=x,y,z):
x: Logical IOX number
y: “P” for Primary BIO configuration, and “S” for Secondary BIO configuration
z: “S” if SCSI SPLIT Mode is selected, and “N” if it is deselected.
(For 32Way(H))
---- CELL0 ------------------------------------------- 19:20:23,07/31/2005 ---
CELL0 (loc=M-14/23)
CNX00
ONLINE
enable
DEG part.0 (LCN=2)
ONLINE
DISABLE ---
DISABLE ---
PROC00
offline
ONLINE
PROC01
enable
enable
---
CXI port0
CXI port2
CNX01
ONLINE
--- --->XBX00 CXI_P0
offline
ONLINE
DISABLE --- --->XBX00 CXI_P1
DISABLE ---
DISABLE* ---
(f)
PROC02
offline
nonexist.
offline
offline
ONLINE
PROC03
CXI port0
CXI port2
MMX00
DISABLE --- --->XBX10 CXI_P0
DISABLE --- --->XBX10 CXI_P1
enable
enable
enable
enable
DEG
DEG
DEG
DEG
MMX01
MMX02
offline
offline
offline
MMX03
855-900549
2-60
Download from Www.Somanuals.com. All Manuals Search And Download.
Base Module
(For 32Way(B))
---- CELL0 ------------------------------------------- 19:20:23,07/31/2005 ---
CELL0 (loc=M-14/23)
CNX00
ONLINE
enable
DEG part.0 (LCN=2)
ONLINE
DISABLE ---
DISABLE ---
PROC00
offline
ONLINE
PROC01
enable
---
PROC02
offline
nonexist.
DISABLE* ---
PROC03
TAG0_e0
TAG0_e1
TAG0_o0
TAG0_o1
CXI port0
CXI port1
CXI port2
CXI port3
MMX00
--------- -------- DEG
--------- -------- DEG
--------- -------- DEG
--------- -------- DEG
ONLINE
enable
--- --->XBX00 CXI_P0
offline
offline
offline
ONLINE
DISABLE --- --->XBX01 CXI_P0
DISABLE --- --->XBX10 CXI_P0
DISABLE --- --->XBX11 CXI_P0
enable
enable
enable
enable
DEG
DEG
DEG
DEG
MMX01
offline
offline
offline
MMX02
MMX03
(For 8Way)
---- CELL0 ------------------------------------------- 19:20:23,07/31/2005 ---
CELL0 (loc=M-00/08)
CNX00
ONLINE
enable
enable
DEG part.0 (LCN=2)
---
offline
offline
ONLINE
PROC00
DISABLE ---
enable ---
DISABLE* ---
PROC01
PROC02
offline
nonexist.
PROC03
TAG0_e0
TAG0_e1
TAG0_o0
TAG0_o1
CXI port0
CXI port1
CXI port2
CXI port3
MMX00
--------- -------- DEG
--------- -------- DEG
--------- -------- DEG
--------- -------- DEG
(f)
ONLINE
ONLINE
ONLINE
ONLINE
ONLINE
offline
enable
enable
enable
enable
enable
--- --->PCIBAY0_P0
--- --->PCIBAY1_P1
--- --->CELL1 CXI_P2
--- --->CELL1 CXI_P3
DEG
MMX01
DISABLE DEG
2-61
855-900549
Download from Www.Somanuals.com. All Manuals Search And Download.
Base Module
(For ISPF)
---- CELL0 ------------------------------------------- 19:20:23,07/31/2005 ---
CELL0 (loc=M-00/10)
CNX00
ONLINE
enable
enable
DEG part.0 (LCN=2)
---
ONLINE
PROC00
offline
ONLINE
DISABLE ---
enable ---
DISABLE* ---
PROC01
PROC02
offline
nonexist.
PROC03
TAG0_e0
TAG0_e1
TAG0_o0
TAG0_o1
CXI port0
CXI port1
CXI port2
CXI port3
MMX00
--------- -------- DEG
--------- -------- DEG
--------- -------- DEG
--------- -------- DEG
(f)
ONLINE
ONLINE
ONLINE
ONLINE
ONLINE
ONLINE
enable
enable
enable
enable
enable
enable
--- --->PCIBAY0_P0
--- --->XBX00 CXI_P0
--- --->CELL1 CXI_P2
--- --->CELL1 CXI_P3
DEG
MMX01
DEG
(For 32Way(B), 8Way, or ISPF)
---- MMX00 ------------------------------------------- 19:20:23,07/31/2005 ---
MMX00 ONLINE enable DEG
ROW00[DIMM00:01] --- SBE=000:000 MBE=000
2GB --------- enable
2GB --------- enable
8GB --------- enable
8GB --------- enable
ROW01[DIMM02:03]
ROW02[DIMM04:05]
ROW03[DIMM06:07]
--- SBE=000:000 MBE=000
--- SBE=000:000 MBE=000
--- SBE=000:000 MBE=000
(g)
---- MMX01 ------------------------------------------- 19:20:23,07/31/2005 ---
MMX01 ONLINE enable
ROW04[DIMM08:09]
2GB --------- enable
2GB --------- enable
8GB --------- enable
8GB --------- enable
--- SBE=000:000 MBE=000
--- SBE=000:000 MBE=000
--- SBE=000:000 MBE=000
--- SBE=000:000 MBE=000
ROW05[DIMM10:11]
ROW06[DIMM12:13]
ROW07[DIMM14:15]
(MMXx2 and MMXx3 are only shown for 32Way(B).)
---- MMX02 ------------------------------------------- 19:20:23,07/31/2005 ---
MMX02 ONLINE enable DEG
ROW08[DIMM16:17] --- SBE=000:000 MBE=000
2GB --------- enable
8GB --------- enable
2GB --------- enable
ROW09[DIMM18:19]
ROW10[DIMM20:21]
--- SBE=000:000 MBE=000
--- SBE=000:000 MBE=000
ROW11[DIMM22:23] --GB --------- DISABLE --- SBE=000:000 MBE=000
(h)
---- MMX03 ------------------------------------------- 19:20:23,07/31/2005 ---
MMX03
ROW12[DIMM24:25]
ONLINE
enable
DEG
--- SBE=000:000 MBE=000
2GB --------- enable
8GB --------- enable
2GB --------- enable
ROW13[DIMM26:27]
ROW14[DIMM28:29]
--- SBE=000:000 MBE=000
--- SBE=000:000 MBE=000
ROW15[DIMM30:31] --GB --------- DISABLE --- SBE=000:000 MBE=000
855-900549
2-62
Download from Www.Somanuals.com. All Manuals Search And Download.
Base Module
(For 32Way(H))
---- MMX00 ------------------------------------------- 19:20:23,07/31/2005 ---
MMX00
DIR00
ROW00[DIMM00:01] 16GB --------- enable
DIR01 8GB --------- enable
ROW01[DIMM02:03] 16GB --------- enable
ONLINE
enable
DEG
--- SBE=000
--- SBE=000:000 MBE=000
--- SBE=000 MBE=000
--- SBE=000:000 MBE=000
--- SBE=000 MBE=000
--- SBE=000:000 MBE=000
MBE=000
8GB --------- enable
MBE=000
DIR02
1GB --------- enable
1GB --------- enable
ROW02[DIMM04:05]
DIR03
--GB --------- DISABLE --- SBE=000
ROW03[DIMM06:07] --GB --------- DISABLE --- SBE=000:001 MBE=000
(g)
---- MMX01 ------------------------------------------- 19:20:23,07/31/2005 ---
MMX01
DIR04
ROW04[DIMM08:09] 16GB --------- enable
DIR05 8MB --------- enable
ROW05[DIMM10:11] 16GB --------- enable
ONLINE
enable
DEG
--- SBE=000
--- SBE=000:000 MBE=000
--- SBE=000 MBE=000
--- SBE=000:000 MBE=000
--- SBE=000 MBE=000
--- SBE=000:000 MBE=000
MBE=000
8GB --------- enable
MBE=000
DIR06
1GB --------- enable
1GB --------- enable
ROW06[DIMM12:13]
DIR07
--GB --------- DISABLE --- SBE=000
ROW07[DIMM14:15] --GB --------- DISABLE --- SBE=000:000 MBE=000
---- MMX02 ------------------------------------------- 19:20:23,07/31/2005 ---
MMX02
DIR08
ONLINE
enable
2GB --------- enable
4GB --------- enable
--GB --------- enable
--- SBE=000
--- SBE=000:000 MBE=000
--- SBE=000 MBE=000
--- SBE=000:000 MBE=000
--- SBE=000 MBE=000
--- SBE=000:000 MBE=000
--- SBE=000 MBE=000
--- SBE=000:000 MBE=000
MBE=000
ROW08[DIMM16:17]
DIR09
ROW09[DIMM18:19] --GB --------- enable
DIR10
2GB --------- enable
4GB --------- enable
--GB --------- enable
ROW10[DIMM20:21]
DIR11
ROW11[DIMM22:23] --GB --------- enable
(h)
---- MMX03 ------------------------------------------- 19:20:23,07/31/2005 ---
MMX03 ONLINE enable
DIR12
2GB --------- enable
4GB ---------- enable
--GB --------- enable
--- SBE=000
--- SBE=000:000 MBE=000
--- SBE=000 MBE=000
--- SBE=000:000 MBE=000
--- SBE=000 MBE=000
--- SBE=000:000 MBE=000
--- SBE=000 MBE=000
--- SBE=000:000 MBE=000
MBE=000
ROW12[DIMM24:25]
DIR13
ROW13[DIMM26:27] --GB ---------- enable
DIR14
2GB --------- enable
4GB ---------- enable
--GB --------- enable
ROW14[DIMM28:29]
DIR15
ROW15[DIMM30:31] --GB ---------- enable
2-63
855-900549
Download from Www.Somanuals.com. All Manuals Search And Download.
Base Module
(For 32Way(B), 8Way, or ISPF)
---- TAG0_e ------------------------------------------ 19:20:23,07/31/2005 ---
TAG0_e0 --------- -------- DEG
TAG0_e0 TAGL0
--------- enable
--------- enable
---
---
TAG0_e0 TAGL1
TAG0_e0 TAGL2
TAG0_e0 TAGL3
TAG0_e0 TAGL4
TAG0_e0 TAGL5
--------- DISABLE* ---
--------- enable
--------- enable
--------- enable
---
---
---
TAG0_e1
--------- -------- DEG
TAG0_e1 TAGL0
TAG0_e1 TAGL1
TAG0_e1 TAGL2
TAG0_e1 TAGL3
TAG0_e1 TAGL4
TAG0_e1 TAGL5
--------- enable
--------- enable
---
---
--------- DISABLE* ---
--------- enable
--------- enable
--------- enable
---
---
---
(i)
---- TAG0_o ---------------------------------------- 19:20:23,07/31/2005 ---
TAG0_o0
TAG0_o0 TAGL0
--------- --------
--------- enable
--------- enable
--------- enable
--------- enable
--------- enable
--------- enable
--------- --------
--------- enable
--------- enable
--------- enable
--------- enable
--------- enable
--------- enable
---
---
---
---
---
---
TAG0_o0 TAGL1
TAG0_o0 TAGL2
TAG0_o0 TAGL3
TAG0_o0 TAGL4
TAG0_e0 TAGL5
TAG0_o1
TAG0_o1 TAGL0
TAG0_o1 TAGL1
TAG0_o1 TAGL2
TAG0_o1 TAGL3
TAG0_o1 TAGL4
TAG0_e1 TAGL5
---
---
---
---
---
---
(Subsequently listed to the max. CELL number.)
---- CELL1 ------------------------------------------- 19:20:23,07/31/2005 ---
:
:
:
855-900549
2-64
Download from Www.Somanuals.com. All Manuals Search And Download.
Base Module
(For 32Way(B))
---- XBX_C0 ------------------------------------------ 19:20:23,07/31/2005 ---
XBX_C0(loc=M-14/23)
XBX00 (loc=M-14/23)
CXI port00
ONLINE
ONLINE
ONLINE
offline
ONLINE
offline
ONLINE
ONLINE
ONLINE
offline
enable
enable
enable
DEG
DEG
--- --->CELL0 CXI_P0
CXI port01
DISABLE* --- --->CELL1 CXI_P0
enable --- --->CELL2 CXI_P0
DISABLE* --- --->CELL3 CXI_P0
CXI port02
CXI port03
IB_CABLE port04
IB_CABLE port05
XXI port06
enable
enable
enable
--- --->PCIBAY0_P0
--- --->PCIBAY2_P0
--- --->XBX_C2_P06
XXI port07
DISABLE* --- --->XBX_C2_P07
(j)
XBX01 (loc=M-14/23)
CXI port10
ONLINE
ONLINE
offline
ONLINE
offline
ONLINE
ONLINE
ONLINE
offline
enable
enable
DEG
--- --->CELL0 CXI_P1
CXI port11
DISABLE* --- --->CELL1 CXI_P1
enable --- --->CELL2 CXI_P1
DISABLE* --- --->CELL3 CXI_P1
CXI port12
CXI port13
IB_CABLE port14
IB_CABLE port15
XXI port16
enable
enable
enable
--- --->PCIBAY1_P0
--- --->PCIBAY3_P0
--- --->XBX_C2_P16
XXI port17
DISABLE* --- --->XBX_C2_P17
(For 32Way(H))
---- XBX_C0 ------------------------------------------ 19:20:23,07/31/2005 ---
XBX_C0(loc=M-14/23)
XBX00 (loc=M-14/23)
CXI port00
ONLINE
ONLINE
ONLINE
offline
ONLINE
offline
ONLINE
ONLINE
ONLINE
offline
offline
enable
enable
enable
DEG
DEG
--- --->CELL0 CXI_P00
CXI port01
DISABLE* --- --->CELL0 CXI_P10
enable --- --->CELL2 CXI_P00
DISABLE* --- --->CELL2 CXI_P10
CXI port02
CXI port03
IB_CABLE port04
IB_CABLE port05
XXI port06
enable
enable
enable
--- --->PCIBAY0_P0
--- --->PCIBAY2_P0
--- --->XBX_C2_P06
XXI port07
DISABLE* --- --->XBX_C2_P17
DISABLE* --- --->XBX_C0_P18
XXI port08
(j)
XBX01 (loc=M-14/23)
CXI port10
ONLINE
ONLINE
offline
ONLINE
offline
ONLINE
ONLINE
ONLINE
offline
offline
enable
enable
DEG
--- --->CELL1 CXI_P00
CXI port11
CXI port12
DISABLE* --- --->CELL1 CXI_P10
enable --- --->CELL3 CXI_P00
DISABLE* --- --->CELL3 CXI_P10
CXI port13
IB_CABLE port14
IB_CABLE port15
XXI port16
enable
enable
enable
--- --->PCIBAY1_P0
--- --->PCIBAY3_P0
--- --->XBX_C2_P16
XXI port17
DISABLE* --- --->XBX_C2_P07
enable --- --->XBX_C0_P08
XXI port18
The XBX is non-existent on the 8Way.
(For ISPF)
---- XBX_C0 ------------------------------------------ 19:20:23,07/31/2005 ---
XBX_C0(loc=M-00/10)
XBX00 (loc=M-00/10)
CXI port00
ONLINE
ONLINE
ONLINE
offline
ONLINE
ONLINE
enable
enable
enable
DEG
DEG
--- --->CELL0 CXI_P1
(j)
CXI port01
DISABLE* --- --->CELL1 CXI_P1
IB_CABLE port04
IB_CABLE port05
enable
enable
--- --->SYS1 XBX_C0_P04
--- --->SYS1 XBX_C0_P05
2-65
855-900549
Download from Www.Somanuals.com. All Manuals Search And Download.
Base Module
(For 32Way, subsequently listed to the max. XBX Card number.)
---- XBX_C1 ------------------------------------------ 19:20:23,07/31/2005 ---
:
:
:
(32Way)
---- PCIBAY0(D) -------------------------------------- 19:20:23,07/31/2005 ---
PCIBAY0(D) (loc=M-00/uu) ONLINE
IOX00
IB_CABLE port0
enable
enable
enable
enable
enable
enable
enable
enable
enable
enable
enable
DEG part.0 (LIN=2,P,S)
ONLINE
ONLINE
ONLINE
ONLINE
ONLINE
ONLINE
ONLINE
ONLINE
ONLINE
ONLINE
offline
ONLINE
ONLINE
ONLINE
ONLINE
ONLINE
ONLINE
offline
offline
offline
DEG
--- --->XBX_C0_P04
IB_CABLE port1
IOC00
--- --->XBX_C2_P04
DEG
IOC01
DEG
GXB00
--- BIO(primary)
*2
*2
*2
CORE PCI001
CORE PCI002
---
---
DEG
---
PXH00
(k)
PCI001
PCI002
DISABLE ---
PXH01
enable
enable
enable
enable
enable
enable
---
---
---
---
---
---
PCI003
PCI004
PXH02
PCI005
PCI006
PXH03
DISABLE ---
PCI007
PCI008
enable
enable
---
---
*2: Listed for the PCI Bay in which the Core Cards are installed.
(iSPF)
---- PCIBAY0(D) -------------------------------------- 19:20:23,07/31/2005 ---
PCIBAY0(D) (loc=M-00/uu) ONLINE
IOX00
IXI port0
enable
enable
enable
enable
enable
enable
enable
enable
enable
enable
DEG part.0 (LIN=2,P,N)
ONLINE
ONLINE
ONLINE
ONLINE
ONLINE
ONLINE
ONLINE
ONLINE
ONLINE
offline
ONLINE
ONLINE
ONLINE
ONLINE
ONLINE
ONLINE
offline
offline
offline
DEG
--- --->XBX_C0_P05
IOC00
IOC01
DEG
DEG
GXB00
--- BIOS(primary)
*3
*3
*3
CORE PCI001
CORE PCI002
---
---
DEG
---
PXH00
(k)
PCI001
PCI002
DISABLE ---
PXH01
enable
enable
enable
enable
enable
enable
---
---
---
---
---
---
PCI003
PCI004
PXH02
PCI005
PCI006
PXH03
DISABLE ---
PCI007
PCI008
enable
enable
---
---
*3: Listed for the PCI Bay in which the Core Cards are installed.
855-900549
2-66
Download from Www.Somanuals.com. All Manuals Search And Download.
Base Module
(8Way’s internal PCIBAY)
---- PCIBAY0(D) -------------------------------------- 19:20:23,07/31/2005 ---
PCIBAY0(D) (loc=M-00/uu) ONLINE
IOX00
IXI port0
enable
enable
enable
enable
enable
enable
enable
enable
enable
enable
enable
DEG part.0 (LIN=2,S,S)
ONLINE
ONLINE
ONLINE
ONLINE
ONLINE
ONLINE
ONLINE
ONLINE
ONLINE
ONLINE
offline
ONLINE
ONLINE
ONLINE
ONLINE
ONLINE
ONLINE
offline
offline
offline
DEG
--- --->CELL0 CXI_P0
IXI port1
IOC00
--- --->CELL1 CXI_P1
DEG
IOC01
DEG
GXB00
--- BIO(secondary)
*4
*4
*4
CORE PCI001
CORE PCI002
---
---
DEG
---
PXH00
PCI001
PCI002
DISABLE ---
PXH01
enable
enable
enable
enable
enable
enable
---
---
---
---
---
---
PCI003
PCI004
(k)
PXH02
PCI005
PCI006
PXH03
DISABLE ---
PCI007
PCI008
enable
enable
---
---
*4: Listed for the PCI Bay in which the Core Cards are installed. When the Duplicated BIO
mode is inactive, the GXB with a secondary BIO becomes invalid at the time of boot. Also
the GXB with unused BIO becomes invalid at the time of boot.
GXB00
CORE PCI001
CORE PCI002
offline
offline
offline
disable. ---
disable. --- BIO(not used)
disable. ---
If no Core Cards are installed, the GXB00 and its subcomponent PCIs are not listed.
(Subsequently listed to the max. PCI Bay number.)
---- PCIBAY1(D) -------------------------------------- 19:20:23,07/31/2005 ---
:
:
2-67
855-900549
Download from Www.Somanuals.com. All Manuals Search And Download.
Base Module
---- PCIBAY0(D) -------------------------------------- 19:20:23,07/31/2005 ---
PCI001: VID:xxxx DID:xxxx PCI err_rec.: no IO mapping: no
No.:xxxxxyyyyyzzzzzwwwwwvvvvvuuuuu Type:000001111122222333334444455555
PCI002: VID:xxxx DID:xxxx PCI err_rec.: no IO mapping: no
No.:xxxxxyyyyyzzzzzwwwwwvvvvvuuuuu Type:000001111122222333334444455555
PCI003: VID:xxxx DID:xxxx PCI err_rec.: no IO mapping: no
No.:xxxxxyyyyyzzzzzwwwwwvvvvvuuuuu Type:000001111122222333334444455555
PCI004: VID:xxxx DID:xxxx PCI err_rec.: no IO mapping: no
No.:xxxxxyyyyyzzzzzwwwwwvvvvvuuuuu Type:000001111122222333334444455555
PCI005: VID:xxxx DID:xxxx PCI err_rec.: no IO mapping: no
No.:xxxxxyyyyyzzzzzwwwwwvvvvvuuuuu Type:000001111122222333334444455555
PCI006: VID:xxxx DID:xxxx PCI err_rec.: no IO mapping: no
No.:xxxxxyyyyyzzzzzwwwwwvvvvvuuuuu Type:000001111122222333334444455555
(l)
PCI007: VID:xxxx DID:xxxx PCI err_rec.: no IO mapping: no
No.:xxxxxyyyyyzzzzzwwwwwvvvvvuuuuu Type:000001111122222333334444455555
PCI008: VID:xxxx DID:xxxx PCI err_rec.: no IO mapping: no
No.:xxxxxyyyyyzzzzzwwwwwvvvvvuuuuu Type:000001111122222333334444455555
In case the PCI Card is not existent:
PCI007: nonexist.
In the case where PCI Card’s upper level components are disconnected:
PCI007: not available
---- PCIBAY0(D) -------------------------------------- 19:20:23,07/31/2005 ---
Core_PCI001: VID:xxxx DID:xxxx PCI err_rec.: no IO mapping: no
No.:xxxxxyyyyyzzzzzwwwwwvvvvvuuuuu Type:000001111122222333334444455555
Core_PCI002: VID:xxxx DID:xxxx PCI err_rec.: no IO mapping: no
No.:xxxxxyyyyyzzzzzwwwwwvvvvvuuuuu Type:000001111122222333334444455555
(m)
(Subsequently listed to the max. PCI Bay number.)
---- PCIBAY1(D) -------------------------------------- 19:20:23,07/31/2005 ---
:
:
(The number of DPS’s depends on models)
(For 32Way)
---- POWBAYs (Main cabinet) -------------------------- 19:20:23,07/31/2005 ---
POWBAY0 (loc=M-00/03)
DPS00
power-ON enable
DEG
DPS01
DPS02
INVISIBLE
DPS03
INVISIBLE
DPS04
DPS05
nonexist.
nonexist.
(n)
POWBAY1 (loc=M-03/03)
power-ON enable
DEG
DPS10
DPS11
DPS12
DPS13
DPS14
DPS15
INVISIBLE
ALARM
nonexist.
nonexist.
---- POWBAYs (Expansion cabinet) --------------------- 19:20:23,07/31/2005 ---
POWBAY2 (loc=E-00/03)
DPS20
power-ON enable
DEG
(n)
855-900549
2-68
Download from Www.Somanuals.com. All Manuals Search And Download.
Base Module
DPS21
DPS22
INVISIBLE
DPS23
DPS24
nonexist.
nonexist.
nonexist.
nonexist.
nonexist.
nonexist.
nonexist.
nonexist.
nonexist.
DPS25
POWBAY3 (loc=----/---)
DPS30
DPS31
DPS32
DPS33
DPS34
DPS35
(For 8Way/ISPF)
---- POWBAYs ----------------------------------------- 19:20:23,07/31/2005 ---
POWBAY0 (loc=M-03/uu)
power-ON enable
DEG
DPS00
DPS01
INVISIBLE
DPS02
DPS03
DPS04
(o)
POWBAY1 (loc=M-00/03)
power-ON enable
DEG
DPS10
DPS11
DPS12
DPS13
DPS14
DPS15
INVISIBLE
ALARM
nonexist.
nonexist.
* For the 8Way/ISPF model, there are three DPSs in Power Bay 0.
* For the ISPF, Power Bay1 for dual AC systems is not configured.
2-69
855-900549
Download from Www.Somanuals.com. All Manuals Search And Download.
Base Module
(Description)
Description
Description
Lists partition configuration information.
No.
(a)
Lists the configuration of the components located in the Main Cabinet or Main
Chassis.
(b)
(c)
(d)
(e)
(f)
Lists the configurations of the PCI Bays located in the Main Cabinet.
Lists the information of the Power Bays located in the Expansion Cabinet.
Lists the configuration of the PCI Bays located in the Expansion Cabinet.
Lists the configuration of CELL’s subcomponents.
(g)
(h)
(i)
Lists the configuration of MMX’s subcomponents.
Lists the configuration of Memory Daughter Card’s subcomponents.
Lists the configuration of TAG’s subcomponents.
(j)
(k)
(l)
Lists the configuration of XBX Card’s subcomponents.
Lists the configuration of PCI Bay’s subcomponents.
Lists the information of the PCI Cards placed under PXH within the PCI Bay.
Lists the information of the PCI Cards on the Core Card, if any Core Card exists
in the PCI Bay.
Lists the configuration of the subcomponents of the Power Bays located in the
32Way model’s Main and Expansion Cabinets.
Lists the configuration of the subcomponents of the Power Bay located in the
8Way/ISPF model.
(m)
(n)
(o)
855-900549
2-70
Download from Www.Somanuals.com. All Manuals Search And Download.
Base Module
2.4.6.8. HE (Help)
m
X
b
X
u
X
* Always valid without regard to the current system status.
Function:
This command is used to show a command list.
(“HELP” is also usable as well as “HE.”)
(Screen Example)
Description
No.
iSPyz:---> he<ENTER>
iSP commands :
System Control (both customers and maintenance persons)
DF ‒ Shut down the system (override)
DN - Shut down the system
DP - Generate the system dump interrupt
PC - Power cycle
RS - Cold reset the system
UB ‒ Bring up BIOS
UP - Bring up the System
Configuration (both customers and maintenance persons)
HC - Hardware configuration and partitioning
Miscellaneous (both customers and maintenance persons)
CM - Change SP command mode to maintenance mode
DT - SP Date and Time
(a)
EN - Display environmental information
FV - Display firmware versions
HE - Display this help
ML - Display message log
Settings (both customers and maintenance persons)
SG ‒ SP/System settings
SR - Save and restore system CMOS/NvRAM to/from FTP server
HE command terminated.
(Description)
Description
Description
No.
(a)
Shows the help for commands.
2-71
855-900549
Download from Www.Somanuals.com. All Manuals Search And Download.
Base Module
2.4.6.9. ML (Message Log)
m
X
b
X
u
X
* Always valid without regard to the current system status.
Function:
This command is used to show the contents of the iSP’s message buffer.
(Messages that are output as a result of message buffer log display itself are not stored to the
message buffer.)
(Screen Example)
Description
No.
iSPyz:---> ml<ENTER>
ML command displays iSP’s message log buffer.
Select interactive mode? (i[nteractive per page]/a[ll]/CR=exit) : i<ENTER>
(a)
(b)
***** start of message logs *******************************************
xxxxxxxxxxxxxxxxx
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
:
:
xxxxxxxxxxxxxxxxxxxxxx
Next ? (n[ext]/CR=exit) : n<ENTER>
xxxxxxxxxxxxxxxxxxxx
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
:
:
xxxxxxxxxxxxxxxxxxxxxxxxxxx
(c)
Previous/Next ? (p[revious]/n[ext]/CR=exit) : n<ENTER>
xxxxxxxxxxxxxxxxxxxxxxxxxxx
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
:
:
xxxxxxxxxxxxxxxxxxx
(d)
(e)
Previous ? (p[revious]/CR=exit) : <ENTER>
***** end of message logs *********************************************
ML command terminated.
855-900549
2-72
Download from Www.Somanuals.com. All Manuals Search And Download.
Base Module
(Description)
Description
No.
Description
Allows to choose from two modes: one that prompts operator entry for each log
page display, and the other that shows the entire buffer log at a time.
You are prompted entry if a next page exists.
You are prompted entry if a previous and next pages exist.
You are prompted entry if a previous page exists.
(a)
(b)
(c)
(d)
(e)
Shows a command terminated message.
2-73
855-900549
Download from Www.Somanuals.com. All Manuals Search And Download.
Base Module
2.4.6.10. PC (Power Cycle)
m
X
b
u
* The command is executable to the active partition (after automatic system boot/UP
command execution).
Function:
This command is used to cycle system power (system reboot after system DC power off).
Note that this command shuts off system power without regard to the current OS or BIOS status
or notifying nothing to the OS or BIOS.
Partitions that are already off or those being shut down are not the target of this command.
(Screen Example)
Description
No.
iSPyz:---> pc<ENTER>
CAUTION: System power will be turned off without any notice to the softwares
even if they are running.
Enter partition number (0-7/all/CR=exit) : 0<ENTER>
Execute OK? (y/[n]) y<ENTER>
(a)
(b)
PC command was accepted. System power of all partitions will be turned off soon
and then will be turned on.
(c)
mm/dd/yyyy HH:MM:SS 0------- System shutdown started. (SPFW:Rxx.xx)
:
mm/dd/yyyy HH:MM:SS 0------- System shutdown completed. (SPFW:Rxx.xx)
mm/dd/yyyy HH:MM:SS 0------- System initialization started. (SPFW:Rxx.xx)
:
(d)
mm/dd/yyyy HH:MM:SS 0------- System initialization completed. (SPFW:Rxx.xx)
[iSP0m:INFO.2129] partition 0 : handed off the control to BIOS.
(DIPSW = 00000000)
(Description)
Description
Description
No.
Prompts a partition number.
(a)
If “all” is specified, all the existing partitions are the target of this command.
Enter y at this confirmation message if you are sure to continue command
execution.
(b)
A “PC command accepted” message appears.
The actual processing progresses in the background.
Shows the progress in the background.
(c)
(d)
855-900549
2-74
Download from Www.Somanuals.com. All Manuals Search And Download.
Base Module
2.4.6.11. RS (Cold Reset System)
m
X
b
u
* The command is executable to the active partition (after automatic system boot/UP
command execution).
Function:
This command causes the system to be cold-reset.
Note that this command could reset the system while the OS (BIOS) is running, notifying
nothing to the software.
Partitions that are already off or those being shut down are not the target of this command.
(Screen Example)
Description
No.
iSPyz:---> rs<ENTER>
CAUTION: System will be resetted without any notice to the softwares even if
they are running.
Enter partition number (0-7/all/CR=exit) : 0<ENTER>
Execute OK? (y/[n]) y<ENTER>
(a)
(b)
(c)
RS command was accepted. All partitions will be reset soon.
mm/dd/yyyy HH:MM:SS 0------- System shutdown started. (SPFW:Rxx.xx)
:
mm/dd/yyyy HH:MM:SS 0------- System shutdown completed. (SPFW:Rxx.xx)
mm/dd/yyyy HH:MM:SS 0------- System initialization started. (SPFW:Rxx.xx)
:
(d)
mm/dd/yyyy HH:MM:SS 0------- System initialization completed. (SPFW:Rxx.xx)
[iSP0m:INFO.2129] partition 0 : handed off the control to BIOS.
(DIPSW = 00000000)
(Description)
Description
Description
No.
Prompts a partition number.
(a)
If “all” is specified, all the existing partitions are the target of this command.
Enter y at this confirmation message if you are sure to continue command
execution.
(b)
An “RS command accepted” message appears.
The actual processing progresses in the background.
Shows the progress in the background.
(c)
(d)
2-75
855-900549
Download from Www.Somanuals.com. All Manuals Search And Download.
Base Module
2.4.6.12. SG (SP/System Setting)
m
X
B
X
u
X
* Always valid without regard to the current system status.
Function:
This command is used to make various system settings and configure the iSP operation
environment.
Main Menu
Sub Menu
Config. Parameter
System common
Remarks
System common settings
(maintenance only) (*1)
Partition settings
(maintenance only) (*1)
Partition boot methods
and Hot-Plug permission
Partition configuration
Valid after a next
partition boot
Valid after a next
partition boot
System
configuration
settings
Setting for the means
of partition boot and
hot plug enable
display all settings
LAN/Serial settings
Show all system
settings on console.
LAN/serial port
After a
configuration
configuration
change, iSP need
be reset.
FTP server settings
SNMP settings
FTP server settings
SNMP-related
configuration
iSP settings
(*2)
After a
configuration
change, iSP need
be reset.
display all setting
N/A
Show all iSP settings
on the console.
Show all system and
iSP settings on the
console.
display all
settings
(*1)Changes to configuration parameters are only allowed in the Maintenance mode.
(*2)In a duplicated iSP environment, iSP configuration must be done on each of the duplicated
iSPs.
Setting partition boot method and hot-plug permission:
Category
Configuration Parameter
Default Setting
off
[AC LINK MODE]
Specifies whether or not the partition is to be
booted immediately when an AC power is
applied.
AC Link
[Wake on LAN]
Specifies whether partition boot by Wake on LAN off
is enabled or not.
Wake on
LAN
855-900549
2-76
Download from Www.Somanuals.com. All Manuals Search And Download.
Base Module
Category
Configuration Parameter
[Hot Plug permission]
Default Setting
Specifies whether Hot-Plug is enabled or not, for
each of the target components.
Target components: CELL, PCIDBAY, PCIEBAY,
PCI(X) card, and PCI-Ex card
The 8Way model has no PCIDBAY or PCIEBAY
settings.
Hot Plug
permission
off
The 32Way(H) and ISPF require PCI(X) card and
PCI-Ex card settings.
SP LAN/Serial Port Setting:
Category
Configuration Parameter
Default Setting
The following parameter settings are needed
depending on the other device (terminal
emulator) to which the SP is connected as a
local console.
-
Baud rate
9600
8
Data bit width is only listed.
It is unable to be changed.
Stop bit width is only listed.
It is unable to be changed.
Parity is only listed.
It is unable to be changed.
Flow control is only listed.
It is unable to be changed.
Serial port
1
None
RTS/CTS
192.168.119.100
or
IP address for LAN0
192.168.119.101
255.255.255.0
N/A
LAN0
Subnet mask
Gateway IP address
IP address for LAN1. LAN1’s subnet must be
different from LAN0’s subnet.
Subnet mask
192.168.119.200
LAN1
[ISPF only]
255.255.255.0
N/A
Gateway IP address
NTP server’s IP address.
If the server IP address is set, iSP’s internal
clock is corrected every 1 hour.
If the IP address is omitted, the iSP clocks on its
own.
NTP server
N/A
[Self SYSTEM NUMBER]
System number System number (0 or 1).
(*3)
It is used as part of cabinet location numbers.
0
[ISPF only]
Different system numbers must be set for the 2
cabinets that constitute a cluster.
Cabinet
clustering (*3)
[ISPF only]
Specifies whether cabinet clustering is used or
not.
no
Cabinet-clustered
SP
LAN0:
192.168.119.110
LAN1:
For cabinet clustering, the other iSP’s IP
address is specified. LAN1’s subnet must be
different from LAN0’s subnet.
LAN0/1 (*3)
[ISPF only]
192.168.119.210
(*3): If any of these configuration parameters has been changed, reset the SP in ISPF System
2.
2-77
855-900549
Download from Www.Somanuals.com. All Manuals Search And Download.
Base Module
SP default FTP Server Configuration:
Category
Configuration Parameter
Default Setting
N/A
IP address for the default FTP server
Account for the default FTP server (up to 20
characters)
N/A
[Account is case-sensitive.]
Password for the default FTP server, used in pair
with the account (password is not echoed. Up to 78
characters may be used.)
N/A
FTP Server
[Password is case-sensitive.]
Name of the folder to save auto notification
messages (up to 30 characters). Two-byte
characters or space character are not allowed for
the folder name. Characters that are not usable as
folder names on the FTP server are not allowed
either.
N/A
SP SNMP Configuration:
Category
Configuration Parameter
Default Setting
N/A
Manager IP
address [0]
IP address for SNMP manager.
Up to two managers can be configured.
IP address for SNMP manager.
Manager IP
address1
[ISPF only]
Up to two managers can be configured, and up to
two IP addresses are assignable for each manager. N/A
Two IP addresses, if assigned to a manager, must
have different subnet addresses.
Community names for use on the SNMP.
(Up to 3 community names are usable for TRAP,
information acquisition, and information setting
purposes. Up to 16 characters are usable for a
community name.)
“public”
[Community name is case-sensitive.]
Specifies whether message authentication with
higher security using MD5 is to be used with the
SNMP manager.
Key data for message authentication with higher
security using MD5 used with the SNMP manager
(key data has a 16-byte length).
off
Community
name
N/A
[Key data is not echoed.]
System ID used for communications with the
SNMP manager (up to 8 characters are usable).
This system ID is also used for ESMPRO and for
collaboration between ESMPRO and VOE (*1).
A system ID must be set in advance to ESMPRO
installation.
N/A
no
VOE (*4)
collaboration
Specifies whether or not collaboration is made with
VOE (*1), if it exists in the system.
(*4) VOE represents SystemGlobe GlobalMaster.
855-900549
2-78
Download from Www.Somanuals.com. All Manuals Search And Download.
Base Module
Description
No.
Screen examples for partition boot method and hot-plug permission
iSPyz:MNT> sg<ENTER>
Display and modify settings of system and iSP.
s) System settings
i) iSP settings
a) display all settings
(a)
(b)
Select ? (s/i/a/CR=exit) : s<ENTER>
System setting menu:
c) system common settings (maintenance only)
p) partition settings (maintenance only)
b) partition boot methods and Hot-plug permission
a) display all settings
Select ? (c/p/b/a/CR=back) : b<ENTER>
(For 32Way(B))
Partition boot methods and Hot-plug permissions:
| |Wake |Hot-Plug permission
part.| AC- | On | PCI-card |
CELL
| PCI-D | PCI-E
| LINK| LAN |PCI(X)|PCI-EX| add |remv |swap | add |remv | add |remv
-----+-----+-----+------+------+-----+-----+-----+-----+-----+-----+------
0 | off | off | YES | no | YES | no | YES | no | YES | no | no
1 | off | off | YES | no | YES | no | YES | no | YES | no | no
2 | off | off | YES | no | YES | no | YES | no | YES | no | no
3 | off | off | YES | no | YES | no | YES | no | YES | no | no
4 | off | off | YES | no | YES | no | YES | no | YES | no | no
5 | off | off | YES | no | YES | no | YES | no | YES | no | no
6 | off | off | YES | no | YES | no | YES | no | YES | no | no
7 | off | off | YES | no | YES | no | YES | no | YES | no | no
(c)
Modify? (y/[n]) : <ENTER>
(For 8Way)
Partition boot methods and Hot-plug permissions:
| |Wake |Hot-Plug permission
part.| AC- | On | PCI-card |
CELL
| LINK| LAN |PCI(X)|PCI-EX| add |remv |swap
-----+-----+-----+------+------+-----+-----+-----
0 | off | off | YES | no | YES | no | YES
1 | off | off | YES | no | YES | no | YES
2 | off | off | YES | no | YES | no | YES
3 | off | off | YES | no | YES | no | YES
4 | off | off | YES | no | YES | no | YES
5 | off | off | YES | no | YES | no | YES
6 | off | off | YES | no | YES | no | YES
7 | off | off | YES | no | YES | no | YES
(c)
Modify? (y/[n]) : y<ENTER>
(For 32Way(H) or ISPF)
(c)
2-79
855-900549
Download from Www.Somanuals.com. All Manuals Search And Download.
Base Module
Partition boot methods and Hot-plug permissions:
|Wake |Hot-Plug permission
|
part.| AC- | On | PCI-card
| LINK| LAN |PCI(X)|PCI-EX
-----+-----+-----+------+------
0 | off | off | YES | no
1 | off | off | YES | no
2 | off | off | YES | no
3 | off | off | YES | no
4 | off | off | YES | no
5 | off | off | YES | no
6 | off | off | YES | no
7 | off | off | YES | no
Modify? (y/[n]) : y<ENTER>
Enter partition number? (0-7/CR=back) : 2<ENTER>
AC link mode (on/off/CR=skip)
Wake on LAN (on/off/CR=skip)
Hot plug permission:
: <ENTER>
: on<ENTER>
PCI(X) card? (yes/no/CR=skip) : <ENTER>
PCI-Ex card? (yes/no/CR=skip) : <ENTER>
CELL Hot-add ?
(yes/no/CR=skip) : <ENTER>
*2
*2
*2
CELL Hot-remove ? (yes/no/CR=skip) : <ENTER>
CELL Hot-swap ? (yes/no/CR=skip) : <ENTER>
(d)
PCID BAY Hot-add ?
PCID BAY Hot-remove ? (yes/no/CR=skip) : <ENTER> *2 *3
PCIE BAY Hot-add ? (yes/no/CR=skip) : <ENTER> *2 *3
(yes/no/CR=skip) : <ENTER> *2 *3
PCIE BAY Hot-remove ? (yes/no/CR=skip) : <ENTER> *2 *3
*2: For the 32Way(B) model, an inquiry appears.
For the 32Way(H) or ISPF model, no inquiry will appear.
*3: For the 8Way model, no inquiry will appear either.
Enter partition number? (0-7/CR=back) : <ENTER>
(For 32Way(B))
Partition boot methods and Hot-plug permissions:
| |Wake |Hot-Plug permission
part.| AC- | On | PCI-card |
CELL
| PCI-D | PCI-E
| LINK| LAN |PCI(X)|PCI-EX| add |remv |swap | add |remv | add |remv
-----+-----+-----+------+------+-----+-----+-----+-----+-----+-----+------
0 | off | off | YES | no | YES | no | YES | no | YES | no | no
1 | off | off | YES | no | YES | no | YES | no | YES | no | no
2 | off | off | YES | no | YES | no | YES | no | YES | no | no
3 | off | off | YES | no | YES | no | YES | no | YES | no | no
4 | off | off | YES | no | YES | no | YES | no | YES | no | no
5 | off | off | YES | no | YES | no | YES | no | YES | no | no
6 | off | off | YES | no | YES | no | YES | no | YES | no | no
7 | off | off | YES | no | YES | no | YES | no | YES | no | no
(e)
Modify? (y/[n]) :
System setting menu:
c) system common settings (maintenance only)
p) partition settings (maintenance only)
855-900549
2-80
Download from Www.Somanuals.com. All Manuals Search And Download.
Base Module
b) partition boot methods and Hot-plug permission
a) display all settings
Select ? (c/p/b/a/CR=back) : <ENTER>
Display and modify settings of system and iSP.
s) System settings
i) iSP settings
a) display all settings
Select ? (s/i/a/CR=exit) : <ENTER>
(Description)
Description
Description
No.
The Main Menu appears. In the screen example above, option s) System setting
is chosen.
The Sub-Menu for System Setting opens. Option b) partition boot methods is
chosen here.
(a)
(b)
The current setting for partition boot methods appears.
If you wish to change the setting, enter “y.”
Enter values at the prompts.
The modified parameter settings are listed.
Pressing <ENTER> returns the screen to Sub-Menu.
(c)
(d)
(e)
Description
Screen Example for iSP LAN/Serial Parameter Setting:
No.
iSPyz: MNT> sg<ENTER>
Display and modify settings of system and iSP.
s) System settings
i) iSP settings
a) display all settings
(a)
Select ? (s/i/a/CR=exit) : i<ENTER>
iSP setting menu:
c) LAN/Serial settings
f) FTP server settings
s) SNMP settings
(b)
a) display all settings
Select ? (c/s/f/a/CR=back) : c<ENTER>
iSP LAN/Serial console settings :
Console Port
baud rate
data bits
stop bit
: 9600
: 8
: 1
parity : none
flow control : RTS/CTS
(c)
LAN
LAN0 IP address
LAN0 subnet mask
: 192.168.100.31
: 255.255.255.128
2-81
855-900549
Download from Www.Somanuals.com. All Manuals Search And Download.
Base Module
LAN1 IP address
LAN1 subnet mask
gateway IP
: 192.168.100.231
: 255.255.255.128
(ISPF only)
(ISPF only)
: N/A
: N/A
NTP server IP
Self system number : 0
Cooreration with SysX
(ISPF only)
(ISPF only)
: yes
SysX iSP LAN0 IP address : 192.168.100.41 (ISPF only)
SysX iSP LAN1 IP address : 192.168.100.241 (ISPF only)
Modify? (y/[n]) : y<ENTER>
Serial baud rate (9600/19200/38400/CR=skip) : <ENTER>
LAN0 IP address (xxx.xxx.xxx.xxx/n[ot use]/CR=skip) : <ENTER>
LAN0 subnet mask (xxx.xxx.xxx.xxx/CR=skip) : <ENTER>
LAN1 IP address (xxx.xxx.xxx.xxx/n[ot use]/CR=skip) : <ENTER> (ISPF only)
LAN1 subnet mask (xxx.xxx.xxx.xxx/CR=skip) : <ENTER>
gateway IP (xxx.xxx.xxx.xxx/n[ot use]/CR=skip) : <ENTER>
NTP server IP (xxx.xxx.xxx.xxx/n[ot use]/CR=skip) : <ENTER>
(ISPF only)
(d)
Self system number (0-1/CR=skip)
cooperation with SysX (y/n/CR=skip)
: <ENTER>
: <ENTER>
(ISPF only)
(ISPF only)
SysX iSP LAN0 IP address (xxx.xxx.xxx.xxx/CR=skip) : <ENTER> (ISPF only)
SysX iSP LAN1 IP address (xxx.xxx.xxx.xxx/CR=skip) : <ENTER> (ISPF only)
iSP LAN/Serial console settings :
Console Port
baud rate
data bits
stop bit
: 9600
: 8
: 1
parity : none
flow control : RTS/CTS
LAN
LAN0 IP address
LAN0 subnet mask
LAN1 IP address
LAN1 subnet mask
gateway IP
: 192.168.100.31
: 255.255.255.128
: 192.168.100.231
: 255.255.255.128
(e)
: N/A
: N/A
NTP server IP
Self system number : 0
cooperation with SysX
: YES
SysX iSP LAN0 IP address : 192.168.100.41
SysX iSP LAN1 IP address : 192.168.100.241
Modify? (y/[n]) : <ENTER>
iSP setting menu:
c) LAN/Serial settings
f) FTP server settings
s) SNMP settings
(f)
a) display all settings
Select ? (c/s/f/a/CR=back) : <ENTER>
855-900549
2-82
Download from Www.Somanuals.com. All Manuals Search And Download.
Base Module
Display and modify settings of system and iSP.
s) system settings
i) iSP settings
a) display all settings
(g)
Select ? (s/i/a/CR=exit) : <ENTER>
SG command terminated.
(Description)
Description
Description
No.
The Main Menu appears. In the screen example above, option i) iSP settings is
chosen.
(a)
The Sub-Menu for iSP Settings opens. Option c) LAN/Serial settings is chosen
here.
(b)
The current setting for LAN/Serial appears.
If you wish to change the setting, enter “y.”
Enter values at the prompts.
The modified parameter settings are listed.
Pressing <ENTER> returns the screen to Sub-Menu.
The Sub-Menu opens. Pressing <ENTER> returns the screen to Main Menu.
Pressing <ENTER> quits this command.
(c)
(d)
(e)
(f)
(g)
Description
Screen Example for iSP FTP Server Setting:
No.
iSPyz:MNT> sg<ENTER>
Display and modify settings of system and iSP.
s) System settings
i) iSP settings
a) display all settings
(a)
Select ? (s/i/a/CR=exit) : i<ENTER>
iSP setting menu:
c) LAN/Serial settings
f) FTP server settings
s) SNMP settings
(b)
a) display all settings
Select ? (c/s/f/a/CR=back) : f<ENTER>
iSP FTP server settings :
default FTP server IP
default FTP account
folder name for autocall :
: 192.168.100.30
: asamasp
(c)
(d)
Modify? (y/[n]) : y<ENTER>
default FTP server IP (xxx.xxx.xxx.xxx/n[ot use]/CR=skip) : <ENTER>
2-83
855-900549
Download from Www.Somanuals.com. All Manuals Search And Download.
Base Module
default FTP account (CR=skip) : <ENTER>
default FTP password (CR=skip) : <ENTER>
Re-enter default FTP password : <ENTER>
Enter folder name (CR=skip) : <ENTER>
iSP FTP server settings :
default FTP server IP : 192.168.100.30
default FTP account : asamasp
folder name for autocall :
(e)
Modify? (y/[n]) : <ENTER>
iSP setting menu:
c) LAN/Serial settings
f) FTP server settings
s) SNMP settings
(f)
a) display all settings
Select ? (c/s/f/a/CR=back) : <ENTER>
Display and modify settings of system and iSP.
s) system settings
i) iSP settings
a) display all settings
(g)
Select ? (s/i/a/CR=exit) : <ENTER>
SG command terminated.
(Description)
Description
Description
No.
The Main Menu appears. In the screen example above, option i) iSP settings is
chosen.
(a)
The Sub-Menu for iSP Settings opens. Option f) FTP server settings is chosen
here.
(b)
The current FTP server setting appears.
If you wish to change the setting, enter “y.”
Enter values at the prompts.
The modified parameter settings are listed. Pressing <ENTER> returns the
screen to Sub-Menu.
(c)
(d)
(e)
(f)
(g)
The Sub-Menu opens. Pressing <ENTER> returns the screen to Main Menu.
Pressing <ENTER> quits this command.
Description
Screen Example for iSP SNMP Setting:
No.
iSPyz:MNT> sg<ENTER>
Display and modify settings of system and iSP.
(a)
s) System settings
855-900549
2-84
Download from Www.Somanuals.com. All Manuals Search And Download.
Base Module
i) iSP settings
a) display all settings
Select ? (s/i/a/CR=exit) : i<ENTER>
iSP setting menu:
c) LAN/Serial settings
f) FTP server settings
s) SNMP settings
(b)
a) display all settings
Select ? (c/s/f/a/CR=back) : s<ENTER>
iSP SNMP settings :
Manager1 LAN0 IP : 192.168.100.30
Manager1 LAN1 IP : N/A
Manager2 LAN0 IP : N/A
(ISPF only)
(ISPF only)
(ISPF only)
Manager2 LAN1 IP : N/A
Manager IP 1
Manager IP 2
(ISPF only)
(Other than ISPF)
(Other than ISPF)
: N/A
: N/A
community(Trap) : public
community(Get) : public
community(Set) : public
security option : off
(c)
system ID : N/A
cooperation with VOE : no
Do you want to edit these settings? (y/[n]) : y<ENTER>
Serial baud rate (9600/19200/38400/CR=skip) : <ENTER>
Manager1 LAN0 IP (xxx.xxx.xxx.xxx/n[ot use]/CR=skip) : <ENTER> (ISPF only)
Manager1 LAN1 IP (xxx.xxx.xxx.xxx/n[ot use]/CR=skip) : <ENTER> (ISPF only)
Manager2 LAN0 IP (xxx.xxx.xxx.xxx/n[ot use]/CR=skip) : <ENTER> (ISPF only)
Manager2 LAN1 IP (xxx.xxx.xxx.xxx/n[ot use]/CR=skip) : <ENTER> (ISPF only)
Manager IP 1 (xxx.xxx.xxx.xxx/n[ot use]/CR=skip) : <ENTER> (Other than ISPF)
Manager IP 2 (xxx.xxx.xxx.xxx/n[ot use]/CR=skip) : <ENTER> (Other than ISPF)
(d)
community(Trap) (CR=skip) : <ENTER>
community(Get) (CR=skip) : <ENTER>
community(Set) (CR=skip) : <ENTER>
security option (o[n]/of[f]/CR=skip) : o<ENTER>
SNMP key code (CR=skip) : 00112233445566778899aabbccddeeff<ENTER>
re-enter key code
: 00112233445566778899aabbccddeeff<ENTER>
system ID (CR=skip) : <ENTER>
cooperation with VOE (y/n/CR=skip) : <ENTER>
iSP SNMP settings :
Manager1 LAN0 IP : 192.168.100.30
Manager1 LAN1 IP : N/A
Manager2 LAN0 IP : N/A
Manager2 LAN1 IP : N/A
(ISPF only)
(ISPF only)
(ISPF only)
(ISPF only)
(e)
Manager IP 1
: N/A
(Other than ISPF)
2-85
855-900549
Download from Www.Somanuals.com. All Manuals Search And Download.
Base Module
Manager IP 2
: N/A
(Other than ISPF)
community(Trap) : public
community(Get) : public
community(Set) : public
security option : ON
system ID : N/A
cooperation with VOE : no
Do you want to edit these settings? (y/[n]) : <ENTER>
iSP setting menu:
c) LAN/Serial settings
f) FTP server settings
s) SNMP settings
(f)
a) display all settings
Select ? (c/s/f/a/CR=back) : <ENTER>
Display and modify settings of system and iSP.
s) system settings
i) iSP settings
a) display all settings
(g)
Select ? (s/i/a/CR=exit) : <ENTER>
SG command terminated.
(Description)
Description
Description
No.
The Main Menu appears. In the screen example above, option i) iSP settings is
chosen.
The Sub-Menu for iSP Settings opens. Option s) SNMP settings is chosen here.
The current SNMP manager setting appears.
If you wish to change the setting, enter “y.”
Enter values at the prompts.
The modified parameter settings are listed. Pressing <ENTER> returns the
screen to Sub-Menu.
(a)
(b)
(c)
(d)
(e)
(f)
(g)
The Sub-Menu opens. Pressing <ENTER> returns the screen to Main Menu.
Pressing <ENTER> quits this command.
855-900549
2-86
Download from Www.Somanuals.com. All Manuals Search And Download.
Base Module
2.4.6.13. SR (Save System CMOS/NvRAM)
m
X
b
u
* For cautions for using this command, read the following description of function.
Function:
This command is used to read the contents of the system CMOS/NvRAM and save them to the
FTP Server, or in turn, restore them from FTP Server files.
The target partitions of this command must be in the EFI shell prompt state, with their BIOS
booted up. In any other states, not only the correct system operation is not guaranteed, but the
contents of the system CMOS/NvRAM might be destroyed.
RTC data will not be saved to or restored from the CMOS memory.
(Screen Example)
Description
No.
iSPyz:---> sr<ENTER>
CAUTION: This command MUST be used when target system is in EFI shell
prompting. Otherwise CMOS/NvRAM maybeDESTROYEDorthis commanddoNOTwork
properly.
Enter partition number? (0-7/CR=exit) : 1<ENTER>
Save of Restore? (s/r/CR=back) : s<ENTER>
getting CMOS/NvRAM from partition 1...
got.
(a)
(b)
(c)
ERROR: cannot get CMOS/NvRAM from partition 1. Check the state of partition
1.
Enter partition number? (0-7/CR=exit) :
IP of FTP server [default=10.0.0.2] (CR=skip) : 10.0.0.3<ENTER>
account [default=necuser] : necuser<ENTER>
password [default=********] : xxxxxxxx<ENTER>
file path : cmossave/cmos1.bin<ENTER>
(d)
Save OK? (y/[n]) : y<ENTER>
connecting...
uploaded.
(e)
(f)
Enter partition number? (0-7/CR=exit) : 2<ENTER>
Save or Restore? (s/r/CR=back) : r<ENTER>
(h)
IP of FTP server [default=10.0.0.2] (CR=skip) : 10.0.0.3<ENTER>
account [default=necuser] : necuser<ENTER>
password [default=********] : xxxxxxxx<ENTER>
file path : cmossave/cmos2.bin<ENTER>
Restore OK? (y/[n]) : y<ENTER>
connecting...
connected.
(i)
(j)
downloaded.
2-87
855-900549
Download from Www.Somanuals.com. All Manuals Search And Download.
Base Module
ERROR: cmossave/cmos2.bin does not exist.
(k)
Enter partition number? (0-7/CR=exit) :
checking downloaded file.
passed.
restoring CMOS/NvRAM...
completed.
You need to reset the target partition.
(l)
Enter partition number? (0-7/CR=exit) : <ENTER>
SR command terminated.
(m)
(Description)
Description
Description
No.
(a)
(b)
Enter the target partition No., and then choose “s” to start saving.
Shows data reading from the specified partition in progress.
If a read error occurred, an error message appears and the screen
returns to the partition No. prompt.
(c)
(d)
(e)
Enter the save destination FTP Server information.
[Account, password, and file path name are all case-sensitive.]
Up to 20 characters are usable for an account, up to 78 characters for a
password, and up to 100 characters for a file path. If any of them
exceeds these limits, reconfigure the FTP Server as needed.
If you are sure that the server information you entered is correct, enter
“y.”
(f)
(h)
(i)
Shows data saving to the FTP Server in progress.
Shows an example of restore procedure.
Enter FTP Server information for confirmation.
(j)
Shows data restoration from the FTP Server in progress.
If data restoration failed, an error message appears, and the screen
returns to the partition No. prompt.
(k)
(l)
(m)
Shows data restoration to the specified partition in progress.
Pressing <ENTER> quits the SR command.
855-900549
2-88
Download from Www.Somanuals.com. All Manuals Search And Download.
Base Module
2.4.6.14. UB (Bring up BIOS)
m
X
b
u
* The command is executable to the active partition (after automatic system boot/UP
command execution).
Function:
This command is used to boot the BIOS without booting the OS.
It turns the system DC power On, initializes the hardware, and boots up the BIOS, but the EFI
Shell will not boot the OS.
The UP command is needed to boot up the OS.
(Screen Example)
Description
No.
iSPyz:---> ub<ENTER>
This command will bring up the specified partition.
Enter partition number (0-7/all/CR=exit) : all<ENTER>
Execute OK? (y/[n]) y<ENTER>
(a)
(b)
(c)
UB command was accepted. All partitions will run soon.
mm/dd/yyyy HH:MM:SS 0------- System initialization started. (SPFW:Rxx.xx)
[iSP0m:INFO.2094] partition 0 : turning on POWBAY(s)...
:
mm/dd/yyyy HH:MM:SS 0------- System initialization completed. (SPFW:Rxx.xx)
(d)
:
[iSP0m:INFO.2129] partition 0 : handed off the control to BIOS.
(DIPSW = 00000000)
(Description)
Description
Description
No.
Enter partition number.
If “all” is specified, all the existing partitions are the target of this command.
A confirmation message appears.
(a)
If you are sure to continue, enter “y.”
If the first 1 byte of the BIOS virtual DIPSW is not zero, the following
confirmation message will appear:
(b)
Partition x BIOS virtual DIPSW is ON. (DIPSW=xxyyyyyy) Continue? ([y]/n)
If you are sure to continue BIOS boot, enter “y.” If you wish to abort, enter “n.”
A “UB command accepted” message appears.
The actual boot is performed in the background.
Shows boot progress in the background.
(c)
(d)
2-89
855-900549
Download from Www.Somanuals.com. All Manuals Search And Download.
Base Module
2.4.6.15. UP (Bring up System)
m
X
b
u
* This command is valid to inactive partitions (DC Off).
Function:
This command is used to turn the system DC power On, initialize the hardware, and boot up the
BIOS. Whether to subsequently boot the OS depends on the BIOS/EFI settings.
(Screen Example)
Description
No.
iSPyz:---> up<ENTER>
This command will bring up the specified partition.
Enter partition number (0-7/all/CR=exit) : all<ENTER>
Execute OK? (y/[n]) y<ENTER>
(a)
(b)
(c)
UP command was accepted. All partitions will run soon.
mm/dd/yyyy HH:MM:SS 0------- System initialization started. (SPFW:Rxx.xx)
[iSP0m:INFO.2094] partition 0 : turning on POWBAY(s)...
:
(d)
mm/dd/yyyy HH:MM:SS 0------- System initialization completed. (SPFW:Rxx.xx)
[iSP0m:INFO.2129] partition 0 : handed off the control to BIOS.
(DIPSW = 00000000)
(Description)
Description
Description
No.
Enter partition number.
If “all” is specified, all the existing partitions are the target of this command.
(a)
A confirmation message appears.
If you are sure to continue, enter “y.”
If the first 1 byte of the BIOS virtual DIPSW is not zero, the following confirmation
message will appear:
(b)
Partition x BIOS virtual DIPSW is ON.(DIPSW=xxyyyyyy) Continue? ([y]/n)
If you are sure to continue the boot process, enter “y.” If you wish to abort, enter
“n.”
A “UP command accepted” message appears.
The actual boot is performed in the background.
Shows boot progress in the background.
(c)
(d)
End of SEC2
855-900549
2-90
Download from Www.Somanuals.com. All Manuals Search And Download.
Operation Procedure
Chapter 3
Operation Procedure
3.1.
System Startup
System Startup Procedure
3.1.1.
When all installation is completed, the system can be started by following the system startup
procedure. The procedure to turn on the AC power with the AC switch is explained in this section.
When a UPS is connected, turn on the AC power from the UPS. Refer to the UPS manual for the
AC power-on procedure. The system startup flowchart is shown in the next page.
Be sure that all inputs and outputs have been installed and
CAUTION
upgraded.
3-1
855-900549
Download from Www.Somanuals.com. All Manuals Search And Download.
Operation Procedure
Start
Turn on distribution board.
(See step 1 in next page.)
Turn on console PC.
(See step 2 in next page.)
Turn on peripherals.
(See step 3 in next page.)
Expansion power bay/Base module AC ON
(See steps 4 to 6 in next page.)
Operation on SP console.
(See steps 7 to 11 in next page.)
OS Boot
855-900549
3-2
Download from Www.Somanuals.com. All Manuals Search And Download.
Operation Procedure
Startup Flowchart
Step Operation
1
2
3
Turn on the power distribution board.
Turn on the console PC.
Turn on the peripheral units excluded from power control via the cabinet. Check that they
are turned on normally.
4
Check that the AC switch at the top of the front panel of the main cabinet is OFF. If not, turn
it off.
Note) When a UPS is connected, use the AC switch of the USP for power control instead
of the above switch panel.
5
6
7
When the expansion power bay is installed, turn on the AC switch at the back of the
expansion power bay. Then, turn on the AC switch at the lower part of the rear of the base
module.
Turn on the AC switch on the switch panel at the front top of the cabinet.
Note) When a UPS is connected, use the AC switch of the USP for power control instead
of the above switch panel.
On the SP console, enter:
login name: spfw
Password: nec
iSP Main Menu is displayed.
* The above login name and password are default settings. If you changed the password,
enter that password.
8
9
Enter “s” on the SP console (for selecting S) iSP commands on iSP Main Menu.
Press the ESC key on the SP console (for entering the SP command console).
Check BIOS DIPSW settings and settings in each mode.
Enter SP command “sg” on the SP console to check the settings for each OS.
See 3.4 AC-LINK (auto control) for what to be checked.
See 2.4.6.12 for the “sg” command.
10
11
Enter SP command “up” on the SP console (for turning on the DC power and initiating the
system startup procedure). See 2.4.6.15 for the “up” command.
[Remark]
When the initial system startup is complete, be sure to backup CMOS/NVRAM. It is the
responsibility of the user to backup CMOS/NVRAM. Use SP command “sr” for backup while the
EFI Boot Manager is active. See 2.4.6.13 for the “sr” command.
[Note]
See 2.2.1 Cabinet for the location of the switch panel. See 2.2.6 Power Bay for the location of the
AC switch on the base module and expansion power bay. The number of switches on the switch
panel depends on the number of installed base modules and expansion power bays. Take care
3-3
855-900549
Download from Www.Somanuals.com. All Manuals Search And Download.
Operation Procedure
of the association between these switches and base modules and expansion power bays during
switch operation. The switches on the switch panel are used for immediate power shutdown for
emergency purposes. When a switch on this panel is turned off, data may be destroyed.
855-900549
3-4
Download from Www.Somanuals.com. All Manuals Search And Download.
Operation Procedure
3.1.2.
SP Console Messages
SP console messages displayed during system startup are explained below.
1) Example of SP console screen during SPFW boot
Integrated Service Processor.
Cabinet-ID:xx, Location:iSPy, State:ssssss
iSP login: spfw
<= Enter spfw and press Enter
<= Enter nec and press Enter
iSP password: xxx
Copyright (C) 2006 NEC Corporation, All Rights Reserved.
Welcome to Integrated Service Processor.
iSP FW version : 01.00 generated on 01/01/2006 19:20:33
iSP MAIN MENU
0) OS(BIOS) serial console of partition#0 (SW INITIALIZING)
1) OS(BIOS) serial console of partition#1 (NOT CONFIGURED )
2) OS(BIOS) serial console of partition#2 (NOT CONFIGURED )
3) OS(BIOS) serial console of partition#3 (NOT CONFIGURED )
4) OS(BIOS) serial console of partition#4 (NOT CONFIGURED )
5) OS(BIOS) serial console of partition#5 (NOT CONFIGURED )
6) OS(BIOS) serial console of partition#6 (NOT CONFIGURED )
7) OS(BIOS) serial console of partition#7 (NOT CONFIGURED )
V) Virtual System Operator Panel
S) iSP commands
E) Exit
DISCONNECTALL) disconnect all console connections
iSPyz> s
<= Enter s and press Enter
*****
***** SP Command Mode
***** enter ESC to do the command input effectively *****
***** enter CTRL+B to quit
*****
<= Press ESC
iSPyz:--->
=> To SP Command Console
3-5
855-900549
Download from Www.Somanuals.com. All Manuals Search And Download.
Operation Procedure
2) Example of SP console screen during system startup
iSPyz:---> up
<= Enter up and press Enter
This command will bring up the specified partition.
Enter partition number (0-7/all/CR=exit) : all <= Enter all and press Enter
Execute OK? (y/[n]) y
<= Enter y and press Enter
UP command was accepted. All partitions will run soon.
[iSPyz:INFO.ccc] partition 0 : turning on POWBAY(s)...
[iSPyz:INFO.ccc] partition 0 : turning on XBX_C(s)...
[iSP0m:INFO.ccc] XBX00 SD completed normally.
[iSP0m:INFO.ccc] XBX01 SD completed normally.
:
[iSPyz:INFO.ccc] partition 0 : turning on PCI_BAY(s)...
[iSP0m:INFO.ccc] IOX00 SD completed normally.
:
[iSP0m:INFO.ccc] partition 0 : turning on CELL(s)...
[iSP0m:INFO.ccc] MMX00 SD completed normally.
:
>> SP LOG MESSAGE START (07:6L) <<
11/28/2005 11:31:18 0------- System initialization completed. (SPFW:R00.35)
>> SP LOG MESSAGE END <<
[iSP0m:INFO.ccc] partition 0 : handed off the control to BIOS.
(DIPSW = 00000000)
Note: When multiple partitions are defined, a particular partition can be selected by
entering its partition number instead of entering “all.”
855-900549
3-6
Download from Www.Somanuals.com. All Manuals Search And Download.
Operation Procedure
3.2.
System Shutdown
3.2.1.
System Shutdown Procedure
The procedure to turn off the AC power with the AC switch is explained in this section. When a
UPS is connected, turn off the AC power from the UPS. Refer to the UPS manual for the AC
power-off procedure. The system shutdown flowchart is shown in the next page.
3-7
855-900549
Download from Www.Somanuals.com. All Manuals Search And Download.
Operation Procedure
Start
Shut down OS.
(See step 1 in next page.)
Turn off console PC.
(See step 6 in next page.)
Turn off AC to expansion power bay/base
module.
(See steps 7 and 8 in next page.)
Turn off peripherals.
(See step 9 in next page.)
Turn off distribution board.
(See step 10 in next page.)
Shutdown Completed
855-900549
3-8
Download from Www.Somanuals.com. All Manuals Search And Download.
Operation Procedure
Shutdown Flowchart
Step Operation
1
2
Enter “shutdown –h now” on the OS console.
Check that “Power down.” is displayed.
For details of the shutdown command, refer to the OS manual.
3
4
When multiple partitions have been selected, repeat steps 1 and 2 for all partitions.
Check that the following is displayed on the SP console:
**************************************************
*
*
All DC power has been turned off.
You can turn off AC power.
*
*
**************************************************
5
6
7
Check that the base module fan stops turning.
Turn off the console management PC.
Turn off the AC switch on the switch panel at the front top of the cabinet.
Note) When a UPS is connected, use the AC switch of the USP for power control instead
of the above switch panel.
8
When the expansion power bay is used, turn off the AC switch at the rear of the expansion
power bay. Then, turn off the AC switch at the lower part of the rear of the base module.
Turn off the peripheral units excluded from power control via the cabinet.
Turn off the distribution board.
9
10
[Note]
See 2.2.1 Cabinet for the location of the switch panel. See 2.2.6 Power Bay for the location of the
AC switch on the base module and expansion power bay. The number of switches on the switch
panel depends on the number of installed base modules and expansion power bays. Take care
of the association between these switches and base modules and expansion power bays during
switch operation. The switches on the switch panel are used for immediate power shutdown for
emergency purposes. When a switch on this panel is turned off, data may be destroyed.
3-9
855-900549
Download from Www.Somanuals.com. All Manuals Search And Download.
Operation Procedure
3.2.2.
SP Console Messages
The SP console messages displayed during system shutdown are explained in this section.
1) Example of DC power off display on SP console screen
>> SP LOG MESSAGE START (07:6M) <<
11/28/2005 10:52:09 0------- System shutdown started. (SPFW:R00.35)
>> SP LOG MESSAGE END <<
[iSP0m:INFO.ccc] partition 0 : start-up processing was canceled due to shutdown
request.
[iSP0m:INFO.ccc] partition 0 : turning off CELL(s)...
[iSP0m:INFO.ccc] partition 0 : turning off PCIBAY(s)...
[iSP0m:INFO.ccc] partition 0 : turning off XBX_C(s)...
[iSP0m:INFO.ccc] partition 0 : turning off POWBAY(s)...
>> SP LOG MESSAGE START (07:6M) <<
11/28/2005 10:52:16 0------- System shutdown completed. (SPFW:R00.35)
>> SP LOG MESSAGE END <<
[iSP0m:INFO.ccc]
************************************************
=> DC is off now, and
AC can be turned off.
* All DC power has been turned off.
* You can turn off AC power.
*
*
************************************************
855-900549
3-10
Download from Www.Somanuals.com. All Manuals Search And Download.
Operation Procedure
3.3.
Emergency System Shutdown with AC SW
The switches on the switch panel are provided for forced power off in the event that an
emergency power shutdown is required. Do not use these switches in normal operation.
See 2.2.1 Cabinet for the location of the switch panel. See 2.2.6 Power Bay for the location of the
AC switch on the base module and expansion power bay. The number of switches on the switch
panel depends on the number of installed base modules and expansion power bays. Take care
of the association between these switches and base modules and expansion power bays during
switch operation.
The power can be shut down by pressing the AC switch on the switch panel at the front top of the
cabinet. See 2.2.1 Cabinet for the location of the AC switch. When a UPS is connected, the
power switch of the UPS does the same as the AC switch on the switch panel.
Use the power switch of the UPS for emergency power shutdown. Refer to the UPS manual for
the power-off procedure. With basic configuration, if a UPS is connected, do not operate the
switch panel.
Data may be destroyed when the AC switch is turned off during
CAUTION
operation.
Provide criteria for operating the AC switch and use the switch
CAUTION
according to the criteria.
3.4.
AC-LINK (Auto Control)
When connecting a UPS or a new AOC to the system, you need to decide whether it is controlled
automatically or manually, and if you select automatic control, ask our maintenance personnel to
enable automatic control.
SP command AC link mode
SG On
Description
AC LINK is enabled (it is
disabled by default).
The SP console screen for confirming and executing AC LINK is shown below.
When an automatic control system such as the rack
management system is installed, wait for more than two
minutes after OS shutdown to perform AC power-off control.
CAUTION
* If the AC power-off control starts within two minutes after OS
shutdown, an error will occur during system shutdown, or
the system will not start normally next time.
3-11
855-900549
Download from Www.Somanuals.com. All Manuals Search And Download.
Operation Procedure
1) SP console screen and operation during AC LINK setup
iSPyz:---> sg<ENTER>
<= Enter sg and press Enter
<= Enter s and press Enter
<= Enter b and press Enter
Display and modify settings of system and iSP.
s) System settings
i) iSP settings
a) display all settings
Select ? (s/i/a/CR=exit) : s
System setting menu:
c) system common settings (maintenance only)
p) partition settings (maintenance only)
b) partition boot methods and Hot-plug permission
a) display all settings
Select ? (c/p/b/a/CR=back) : b
Partition boot methods and Hot-plug permissions:
| |Wake |Hot-Plug permission
part.|AC- | On | PCI-card |
CELL
|LINK | LAN |PCI(X)|PCE-EX| add |remv |swap
-----+-----+-----+------+------+-----+-----+-----
0 | off | off | YES | no | no | no | no
1 | off | off | YES | no | no | no | no
Modify? (y/[n]) : y
<= Enter y and press Enter
Enter partition number? (0-7/CR=back) : 0
AC link mode (o[n]/of[f]/CR=skip)
Wake on LAN (o[n]/of[f]/CR=skip)
Hot plug permission:
:
:
<=EnableACLINKandpress Enter
PCI(X) card? (y[es]/n[o]/CR=skip) :
PCI-Ex card? (y[es]/n[o]/CR=skip) :
(Omitted)
Enter partition number? (0-7/CR=back) :
855-900549
3-12
Download from Www.Somanuals.com. All Manuals Search And Download.
Operation Procedure
3.5.
OS Boot
Use the OS console to operate the EFI Shell. Inputs from the
VGA console (PS2 keyboard) may be rejected.
CAUTION
3.5.1.
OS Boot with Boot Manager (Before Installing the OS)
The EFI Boot Manager is automatically activated as the BIOS boots. From the EFI Boot Manager,
you can go to the EFI Shell prompt, start the EFI application, and displays the Boot Maintenance
Menu or EFI System Configuration Menu.
An image of the Menu screen before the OS is installed is shown below. For how to installing
the OSs, refer to the installation guide attached to each OS.
„ Image of the EFI Boot Manager screen (Initial screen prior to OS installation)
E F I Boot M a n a ger ver 1.10 [14.62]
P lea se select a boot opt ion
Acpi(P N P 0A03,0)/P ci(2| 1)/At a (P r im a r y,M a st er )
E F I Sh ell [Bu ilt -in ]
Boot opt ion m a in t en a n ce m en u
Entry for
EFI Syst em Con figu r a t ion M en u
DVD-ROM drive
U se t h e a r r ow k eys t o ch a n ge set t in gs.
3-13
855-900549
Download from Www.Somanuals.com. All Manuals Search And Download.
Operation Procedure
3.5.2.
OS Boot from the EFI (Extensible Firmware Interface) Boot Manager
OS boot options are automatically entered in the EFI Boot Manager as the OS is installed. The
OS can be booted by selecting an OS boot option in the EFI Boot Manager.
The following is an image of EFI Menu screen after SLES9 SP3 is installed:
„ Image of the OS Boot screen displayed by the EFI Boot Manager
E F I Boot M a n a ger ver 1.10 [14.62]
P lea se select a boot opt ion
SLE S9
Acpi(P N P 0A03,0)/P ci(2| 1)/At a (P r im a r y,M a st er )
OS boot disk
E F I Sh ell [Bu ilt -in ]
Boot opt ion m a in t en a n ce m en u
EFI Syst em Con figu r a t ion M en u
U se t h e a r r ow k eys t o ch a n ge set t in gs.
The OS can be booted by selecting the boot path with the cursor keys and pressing the Enter
key in the EFI Boot Manager.
855-900549
3-14
Download from Www.Somanuals.com. All Manuals Search And Download.
Operation Procedure
3.5.3.
EFI Shell
The EFI Shell can be activated from the EFI Boot Manager. The EFI Shell provides Shell
commands for viewing the file system of the boot device, copying the file and various other
operations.
The following is an image of the EFI screen.
„ Image of the EFI screen
Loading.: EFI Shell [Built-in]
EFI Shell version 1.10 [14.62]
Device mapping table
fs0 : Acpi(PNP0A03,3)/Pci(2| 0)/Scsi(Pun0,Lun0)/HD(Part1,Sig0A7C0000)
List of disk
blk0 : Acpi(PNP0A03,3)/Pci(2| 0)/Scsi(Pun0,Lun0)
drives
blk1 : Acpi(PNP0A03,3)/Pci(2| 0)/Scsi(Pun0,Lun0)/HD(Part1,Sig0A7C0000)
blk2 : Acpi(PNP0A03,3)/Pci(2| 0)/Scsi(Pun0,Lun0)/HD(Part2,Sig0A7C0000)
blk3 : Acpi(PNP0A03,0)/Pci(2| 1)/Ata(Primary,Master)
recognized by
the system
Shell>
EFI shell prompt
3.5.4.
EFI Shell Commands
The shell commands that can be executed at the EFI Shell and their usage are explained in this
section. The EFI shell command is executed by entering the command and pressing the Enter
key.
EFI Shell Commands
Command
Description
alias
attrib
alias [-d|-v|-b] [sname]
[value]
Display/create/delete an alias definition in the
EFI Shell environment.
attrib [+a|-a] [+s|-s] [+h|-h]
[+r|-r] [-b] [file ...]
Display/change the file/directory attribute.
[directory ...]
bcfg
bcfg driver|boot [dump –v]
[add # file “desc”] [rm #] [mv
# #]
Display/change the driver/boot configuration.
break
Break
Run the debugger until the breakpoint is
reached.
3-15
855-900549
Download from Www.Somanuals.com. All Manuals Search And Download.
Operation Procedure
Command
Description
cd
cd [path]
Display/change the current directory.
Display the device tree under the handle.
Clear standard outputs.
child
cls
child Handle
cls [color]
comp
connect
comp file1 file2
Compare two files.
Connect [-r] Handle# |
DeviceHandle#
Bind a driver to a device and start the driver.
DriverHandle#
cp
cp [-r] src [src ...] [dst]
date [mm/dd[yy]yy]
Copy a file/directory.
Display/set the date.
Dump a block device.
date
dblk
dblk device [Lba] [blocks]
dh
dh [-p prot_id] [-b] | [handle] Display the handle in the EFI environment.
disconnect
disconnect DeviceHandle#
[DriverHandle#
Disconnect the driver from the device.
[ChildHandle#]] | [-r]
dmem
dmem [Address] [Size]
[;MMIO]
Dump memory.
dmpstore
echo
dmpstore
Display NVRAM variables.
echo [-on|-off]
echo [message]
edit [file]
Display message, or switch echo on/off.
edit
Edit the ASCII/UNICODE file.
Compress a file.
EfiCompress EfiCompress [InFile]
[OutFile]
EfiDecompre EfiDecompress [InFile]
Decompress a file.
ss
[OutFile]
err
err [ErrorLevel]
exit
Display/change the error level.
Exit the EFI Shell.
exit
getmtc
guid
help
hexedit
getmtc
Display the current counter value.
Display GUID in the EFI environment.
Display help.
guid [-b]
help [-b] | [cmd]
hexedit [[-f] FileName | [-d
DiskName Offset Size] |
[-m Offset Size]
Edit file in hex mode.
load
load file [file ...]
Load the EFI driver.
LoadPciRom LoadPciRom [FileName]
Load PCI option ROM image from file.
855-900549
3-16
Download from Www.Somanuals.com. All Manuals Search And Download.
Operation Procedure
Command
Description
ls
ls [-b] [-r] [-a [attrib]] [file]
Display directories/file lists.
map
map [-r|-v|-d] [sname]
[handle] [-b]
Display/define mapping information.
memmap
mkdir
memmap [-b]
Display memory map.
Create a directory.
mkdir dir [dir ...]
mm
mm Address [Width 1|2|4|8] Display/change MEM/IO/PCI.
[;MMIO| ; MEM| ; IO | ;PCI]
[:Value] [-n]
mode
mode [row col]
Display/change the console output device
mode.
mount
mv
mount BlkDevice [sname]
mv src [src ...] [dst]
OpenInfo Handle
pause
Mount the file system on the block device.
Move a file/directory.
OpenInfo
pause
pci
Display the handle/agent protocol.
Pause for an entry with a message displayed.
Display the PCI device configuration space.
pci [Bus Dev [Func] [-i] [-s
[Seg]]]
reset
rm
reset [-w [string]]
rm [-q] file [file ...]
Reset the system.
Delete file/directory.
rm [-q] directory
[directory ...]
set
set [-d|-v|-b] [sname [value]] Display/create/change/delete the EFI
environmental variable.
setsize
stall
setsize newsize file
stall microseconds
time [hh:mm[:ss]]
touch [-r] filename
Set the file size.
Stall the processor in microseconds.
Display the current time, or set time.
time
touch
Set the current time and date in the time and
date attribute of a file.
type
type [-a|-u] [-b] file [file ...]
Display contents of a file.
unload
ver
unload [-n] [-v] HandleIndex Unload the protocol image.
ver Displays version information.
3-17
855-900549
Download from Www.Somanuals.com. All Manuals Search And Download.
Operation Procedure
3.5.5.
OS Boot from EFI Shell
In addition to OS boot from the EFI Boot Manager, the OS can be booted by entering a
command at the EFI Shell. An example of booting the OS from the EFI Shell is shown below.
Example: OS boot from the SCSI disk with the following hardware connection:
− IDE DVD-ROM (Master)
− SCSI HDD (OS boot disk)
(1) Specifying the file system
Change the current file system to the file system connected to the boot device. “fs0”is the
boot device in the screen image shown below.
„ Image of the EFI Shell screen
Shell> map
Boot device
Device m apping table
fs0 : Acpi(PNP0A03,3)/P ci(2| 0)/Scsi(Pun0,Lun0)/H D(Part1,Sig0A7C0000)
fs1 : Acpi(PNP0A03,0)/P ci(2| 1)/Ata(P rim ary,Master)/CDROM(E ntry1)
blk0 : Acpi(PNP0A03,3)/P ci(2| 0)/Scsi(P un0,Lun0)
blk1 : Acpi(PNP0A03,3)/P ci(2| 0)/Scsi(P un0,Lun0)/H D(Part1,Sig0A7C0000)
blk2 : Acpi(PNP0A03,3)/P ci(2| 0)/Scsi(P un0,Lun0)/H D(Part2,Sig0A7C0000)
blk3 : Acpi(PNP0A03,0)/P ci(2| 1)/Ata(P rimary,Master)
blk4 : Acpi(PNP0A03,0)/P ci(2| 1)/Ata(P rimary,Master)/CDROM(Entry1)
Shell> fs0:
Enter “fs0:”
855-900549
3-18
Download from Www.Somanuals.com. All Manuals Search And Download.
Operation Procedure
(2) Booting the OS loader
Boot OS loader SuSE Linux (elilo).
„ Image of OS loader boot screen
fs0:¥ > cd os
fs0:¥ os> ls
Directory of fs0:¥
11/10/05 09:14a <DIR>
0 File
512 EFI
0 bytes
1 Dirs
fs0:¥ > cd efi
fs0:¥ efi¥ > cd suse
fs0:¥ efi¥ Suse> elilo
Boot the OS loader.
* Confirm the storage location of the OS loader and the boot file name by referring to the disk
from which the OS has been installed.
3-19
855-900549
Download from Www.Somanuals.com. All Manuals Search And Download.
Operation Procedure
3.5.6.
EFI Devices
The device connected to the system is managed as “EFI device path.” This section explains the
EFI device path.
1) DVD-ROM device
When the DVD-ROM drive is connected to the IDE secondary channel:
Acpi(PNPA03,0)/Pci(2|1)/Ata(Secondary,Master)
2) SCSI device
Acpi(PNP0A03,1)/Pci(2|0)/xxx/xxx/Scsi(Pun0,Lun0)/HD(Part1,SigFF050000)
Description:
SCSI(Puny,Lunz): Mounting location of the SCSI device (DISK) connected to the SCSI
card.
y: Physical location of the SCSI device
z: Identifier for a logical unit when an SCSI device has multiple
accessible logical units (“0”: Origin)
HD(Part1,SigFF050000): SCSI DISK drive information
Part1: Information on partition 1
SigFF050000: The signature is “FF050000.”
Device path (former part of SCSIxxx):
Example: To install the boot device in the PCI bay (core module):
Host Bus
Slot
-------------------------------------------------------
Acpi(PNP0A03,?)/Pci(?|?)
^UID
^^^Slot Dev#/Func#
Location in PCI bay
C_PCI01
Device path description on the EFI Menu
Acpi(PNP0A03,x)/Pci(3|z)
C_PCI02
Acpi(PNP0A03,x)/Pci(2|z)
-------------------------------------------------------
x = UID: PCI module number identifier
855-900549
3-20
Download from Www.Somanuals.com. All Manuals Search And Download.
Operation Procedure
Computing UID:
UID x=LIOC*16
LIOX=Logical IOX Number :Logical IOX number:
LIOX=0-7
LIOC=Logical IOC Number :Logical IOC number:
LIOC for IOC0=LIOX*2+0
LIOC for IOC1=LIOX*2+1
LIOC=0-15
-----------------------------------------------------
LIOX
0
LIOC
0
UID
0
1
16
1
2
3
4
5
6
7
2
3
4
5
6
7
8
9
10
11
12
13
14
15
32
48
:
:
:
:
:
:
:
:
:
:
:
:
Z: Function number:
3-21
855-900549
Download from Www.Somanuals.com. All Manuals Search And Download.
Operation Procedure
Example:
To install the boot device on the PCI bay (PCI module):
Host Bus PEX PXH Slot
--------------------------------------------------------------------------------------
Acpi(PNP0A03,?)/Pci(?|?)/Pci(?|0)/Pci(?|?)
^UID
^^^Slot Dev#/Func#
Location in PCI bay
Device path description on the EFI Menu
PCI01
PCI02
PCI03
PCI04
PCI05
PCI06
PCI07
PCI08
Acpi(PNP0A03,x)/Pci(2|0)/Pci(0|0)/Pci(2|z)
Acpi(PNP0A03,x)/Pci(2|0)/Pci(0|2)/Pci(2|z)
Acpi(PNP0A03,x)/Pci(4|0)/Pci(0|0)/Pci(2|z)
Acpi(PNP0A03,x)/Pci(4|0)/Pci(0|2)/Pci(2|z)
Acpi(PNP0A03,y)/Pci(2|0)/Pci(0|0)/Pci(2|z)
Acpi(PNP0A03,y)/Pci(2|0)/Pci(0|2)/Pci(2|z)
Acpi(PNP0A03,y)/Pci(4|0)/Pci(0|0)/Pci(2|z)
Acpi(PNP0A03,y)/Pci(4|0)/Pci(0|2)/Pci(2|z)
-------------------------------------------------
x,y = UID : PCI module number identifier
Computing UID: Same as the PCI bay (core module).
855-900549
3-22
Download from Www.Somanuals.com. All Manuals Search And Download.
Operation Procedure
3.5.7.
EFI Boot Option Maintenance
A boot option can be selected on the Boot Option Maintenance Menu which is activated from the
EFI Boot Manager screen by selecting [Boot option maintenance menu] after the power-on
procedure.
„ Image of the EFI Boot Manager screen
E F I B oot M a n a g e r v e r 1 .1 0 [1 4 .6 2 ]
P le a s e s e le ct a b oot op t ion
S L E S 9
A cp i(P N P 0 A 0 3 ,0 )/P ci(2 | 1 )/A t a (S e con d a r y ,M a s t e r )
E F I S h e ll [B u ilt -in ]
B oot op t ion m a in t e n a n ce m e n u
E F I S y s t e m C on fig u r a t ion M e n u
U s e t h e a r r ow k e y s t o ch a n g e s e t t in g s .
See the description of each boot option on the Boot Option Maintenance Menu. “Boot
Maintenance Menu Options” below lists the options that are explained in the subsequent pages.
When you change the settings from the EFI Boot Maintenance Menu, save the new settings with
SP command “sr.” For the “sr” command, see 2.4.6.13.
„ Image of the EFI Boot Option Maintenance screen
E F I B o o t M a i n t e n a n c e M a n a g e r v e r 1 . 1 0 [ 1 4 . 6 2 ]
M a i n M e n u . S e l e c t a n O p e r a t i o n
B o o t f r o m
a
F i l e
A d d a B o o t O p t i o n
D e l e t e B o o t O p t i o n ( s )
C h a n g e B o o t O r d e r
M a n a g e B o o t N e x t s e t t i n g
S e t A u t o B o o t T i m e O u t
C o l d R e s e t
E x i t
3-23
855-900549
Download from Www.Somanuals.com. All Manuals Search And Download.
Operation Procedure
Boot Maintenance Menu Options
Option
Description
Boot from a File
Boot the OS directly from the EFI application.
Add a boot option to the EFI Boot Manager menu.
Delete a boot option or all options.
Add a Boot Option
Delete Boot Option(s)
Change Boot Order
Change the order of boot options according to the HELP
screen by pressing the HELP key.
Manage Boot Next Setting
Set Auto Boot Timeout Value
Select a boot option for the next boot only.
Set a timeout value until the next auto boot (in seconds).
When “0” is specified, the timeout option is disabled. If
nothing is entered, the default “10” seconds is set.
Cold Reset
Exit
Hard reset the system.
Return to the EFI BOOT Manager menu.
855-900549
3-24
Download from Www.Somanuals.com. All Manuals Search And Download.
Operation Procedure
3.5.7.1. Boot from a File
A boot file can be selected from a list of device files by selecting [Boot from a File] on the Main
Menu.
„ Image of the Boot from a File screen
E F I B oot M a in t en a n ce M a n a ger ver 1.10 [14.62]
B oot F r om a F ile. S elect a Volu m e
IA64_E F I [Acp i(P N P 0A03,3)/P ci(2| 0)/S csi(P u n 0,L u n 0)/H D (P a r t 1,S ig0
N O VO LU M E LAB E L [Acp i(P N P 0A03,0)/P ci(2| 1)/At a (P r im a r y,M a st er )]
R em ova ble M ed ia B oot [Acp i(P N P 0A03,0)/P ci(2| 1)/At a (P r im a r y,M a st e
R em ova ble M ed ia B oot [Acp i(P N P 0A03,0)/P ci(2| 1)/At a (S econ d a r y,M a s
Loa d F ile [E F I S h ell [B u ilt -in ]]
E xit
3-25
855-900549
Download from Www.Somanuals.com. All Manuals Search And Download.
Operation Procedure
3.5.7.2. Add a Boot Option
To add a new boot option to the EFI Shell, select [Add a Boot Option] on the Main Menu, and
follow the steps below.
1. Select a device containing the boot file.
2. Select a file in the device.
„ Image of the Add a Boot Option screen
Select AddBoot to displaythe directory tree,
and select a directory from the tree to enter
the boot program.
EFI Boot Maintenance Manager ver 1.10[14.62]
Add A Boot Option, Select a Volume:
IA64_EFI [Acpi(PNP0A03,3)/Pci(2|0)Scsi(Pun0,Lun0)/HD(Part1,Sig0
Default Boot [Acpi(PNP0A03,3)/Pci(2|0)/Scsi(Pun0,Lun0)]
Default Boot [Acpi(PNP0A03,0)/Pci(2|1)/Ata(Primary,Master)]
LoadFileAcpi(PNP0A03,0)/Pci(2|0)/SCSI(Pun0,Lun0)/HD(Part1,Sig0A7C0000)
Load File [EFI Shell [Built-in]]
3. Enter a file name (prerequisite: a ASCII or Unicode file name within 240 characters).
4. Select A, U or N, and press the <Enter> key.
5. Confirm that the new boot option was added, and save the change.
6. The new description is entered in the EFI Boot Menu screen.
„ Image of the Add a Boot Option screen
Specify the title of the new description to enter in the EFI Bo
Filename:xxxxxxxxxxxxxxxx
DevicePath:xxxxxxxxxxxxxx
Enter New Description: OSLOADER
Enter New Option Data Type [A-Ascii, U-Unicode, N-No BootOption]
:Ascii
Enter Boot Option Data [Data will be stored in Ascii String]:
Xxxxx
Save change to NVRAM [Y-Yes N-No]:
Specify the boot parameter for starting the application.
Save the change in NVRAM
855-900549
3-26
Download from Www.Somanuals.com. All Manuals Search And Download.
Operation Procedure
3.5.7.3. Add Boot Option(s)
To delete a boot option or all options, select [Delete Boot Option(s)] from the Main Menu.
Highlight a boot option to delete by placing the cursor on the boot option, and press the <Enter>
key. The selected boot option can also be deleted by pressing the <d> or <D> key. When the
boot option is selected, confirmation message [Delete selected Boot option [Y-Yes N-No] :]
appears. Enter <Y> to delete, or <N> to cancel operation. To delete all boot options, select
[Delete All Boot Options] from the menu. After deletion, select [Save Settings to NVRAM] on the
menu screen, save the change, and exit this menu.
3.5.7.4. Change Boot Order
To change the order of boot options, select [Change Boot Order] from the Main Menu. On the
Change Boot Order screen, highlight a boot option to move by placing the cursor on the boot
option. The selected boot option moves up by one line each time you hit the <U> or <u> key, and
moves down by one line each time you press the <d> or <D> key. Select [Save Settings to
NVRAM] on the menu screen to save the change, and exit this menu. The OS is automatically
booted after ten seconds with the boot option listed at the top on the EFI Boot Manager screen
by default.
„ Image of the Change Boot Order screen
E F I Boot Ma n a ger ver 1.10 [14.62]
Ch a n ge boot or der . Select a n Oper a tion
SLE S9
Acpi(P N P 0A03,0)/P ci(2| 1)/Ata (Secon da r y,Ma ster )
E F I Sh ell [Bu ilt-in ]
Delete All Boot Option s
Sa ve Settin gs to N VRAM
H elp
E xit
Acpi(P N P 0A03,0)/P ci(2| 1)/At a (Secon a da r y,Ma ster )
Boot 0000
3-27
855-900549
Download from Www.Somanuals.com. All Manuals Search And Download.
Operation Procedure
3.5.7.5. Manage BootNext Setting
To set the most favored boot option for the next boot or reset the BootNext option, select
[Manage BootNext Setting] from the Main Menu. On the Manage BootNext Setting screen,
highlight a boot option by placing the cursor on the boot option, and press the <b> or <B> key to
make this option as “BootNext.” To remove the BootNext setting, select [Reset BootNext Setting],
and press the <R> or <r> key. Select [Save Settings to NVRAM] on the menu screen, save the
change, and exit this menu.
„ Image of the Manage BootNext Setting screen
E F I Boot Ma n a ger ver 1.10 [14.62]
Ma n a ge BootN ext sett in g. Select a n Oper a tion
SLE S9
Acpi(P N P 0A03,0)/P ci(2| 1)/At a (Secon da r y,Ma ster )
E F I Sh ell [Bu ilt-in ]
Delete All Boot Option s
Sa ve Set tin gs to N VRAM
H elp
E xit
Acpi(P N P 0A03,0)/P ci(2| 1)/Ata (Secon da r y,Ma ster )
Boot0000
855-900549
3-28
Download from Www.Somanuals.com. All Manuals Search And Download.
Operation Procedure
3.5.7.6. Set Auto Boot Timeout
To change the timeout value until the next auto boot (TimeValue) from the default setting (10
seconds), select [Set Auto Boot Timeout] from the Main Menu. Specify the timeout value (in
seconds) in the Set Timeout Value option. If the value 0 (zero) is specified, the OS is booted
immediately. There are three ways to disable auto boot:
• Using the Delete/Disable Timeout menu.
• Setting the timeout value to 65535<0xFFFF>.
• Pressing a key when EFI is booting to disable the timeout count down. The timeout value
selected on the Set Timeout Value menu has been saved.
„ Image of the Set Auto Boot Timeout screen
E F I B oot M a in t en a n ce M a n a ger ver 1.10 [14.62]
S et Au t o B oot Tim eou t . S elect a n O p t ion
S et Tim eou t Va lu e
D elet e/D isa ble T im eou t
H elp
E xit
3-29
855-900549
Download from Www.Somanuals.com. All Manuals Search And Download.
Operation Procedure
3.5.7.7. Setting the Network Boot
To enable PXE Boot, change the EFI Boot Manager using the EFI Boot Option Maintenance
menu. This section explains how to change the EFI Boot Manager with an example of changing
the network installation menu for HP-UX.
Before change: Example) Immediately after HP-UX is installed.
E F I Boot Ma n a ger ver 1.10 [14.62]
P lea se select a boot option
H P -U X P r im a r y Boot: 8/0/7/2/0.8.0.255.1.0.7
Acpi(P N P 0A03,0)/P ci(2| 1)/At a (Secon da r y,Ma ster )
E F I Sh ell [Bu ilt-in ]
Boot option m a in ten a n ce m en u
E F I Syst em Con figu r a tion Men u
U se th e a r r ow keys to ch a n ge settin gs.
Before change
After change: After the menu is changed.
E F I Boot Ma n a ger ver 1.10 [14.62]
P lea se select a boot option
H P -U X P r im a r y Boot: 8/0/7/2/0.8.0.255.1.0.7
Acpi(P N P 0A03,0)/P ci(2| 1)/At a (Secon da r y,Ma ster )
Acp i(P N P 0A03,0)/P ci(3| 0)/M a c(00004C717743)
E F I Sh ell [Bu ilt-in ]
Boot option m a in ten a n ce m en u
E F I Syst em Con figu r a tion Men u
U se th e a r r ow keys to ch a n ge settin gs.
After change
855-900549
3-30
Download from Www.Somanuals.com. All Manuals Search And Download.
Operation Procedure
Changing procedure:
1) Activate the EFI Boot Manager.
2) Select Boot Option Maintenance Menu.
3) Select Add Boot Option.
a) When Add Boot Option is chosen, the device paths containing the boot file are listed.
The entry “Mac(xxxx)” corresponds to the LAN card for PXE Boot. Select the entry of
a card used for PXE BOOT according to the MAC address.
Example) To use a card having MAC address: 00004C717743 for PXE BOOT:
Select the entry Acpi(PNP0A03,0)/Pci(3|0)/Mac(00004C717743).
Note 1: When multiple LAN cards are provided for multiple PXE network cards of
PXE having multiple ports, the corresponding number of entries are
displayed with each having a unique MAC address. Select the LAN cards
according to their MAC addresses.
Note 2: It is recommended to write down the LAN cards MAC addresses for this
work.
b) Save the selected entry as a new boot option of the EFI Boot Manager.
• Any character string can be used for the New Description, but a name easy to
identify the LAN card and the system is preferable.
• Boot Option Data is not required.
c) Enter “Y” for Save Change to NVRAM[Y/N].
4) Return to the EFI Boot Manager and select Boot Option Maintenance Menu again.
5) Change the order of boot options on the Change Boot Order screen.
↓
Select Save Settings to NVRAM, and save the change.
3-31
855-900549
Download from Www.Somanuals.com. All Manuals Search And Download.
Operation Procedure
3.5.7.8. Changing BIOS Settings
The BIOS settings may need to be changed using the EFI System Configuration Menu.
After changing the BIOS settings, save the change using SP command “sr.” For the “sr”
command, see 2.4.6.13.
(1) System interrupt
Check the BIOS settings for the hardware components shown below before installing
Windows 2003 Server. Part of the BIOS settings is required for operating Windows 2003
Server. Be sure to set the proper system interrupt for the OS to install.
Confirmation and setting:
Select EFI System Configuration Menu from the EFI Boot Manager.
↓
Select Boot Configuration.
↓
The screen below appears.
View Shrink total number of interrupt vector up to 256.
When the set value does not correspond to the OS, change it to a correct value.
↓
Select Exit, save the change, and reboot the OS to validate the change.
EFI System Configuration Menu
Boot Configuration
Shrink total number of interrupt vectors up to 256:
Device Information
[ENABLED]
Help
Exit
Press 'ENTER' key to select an option.
855-900549
3-32
Download from Www.Somanuals.com. All Manuals Search And Download.
Operation Procedure
OS
Setting (Note)
--------------------------------------------------------
Windows Server 2003 Datacenter Edition
Windows Server 2003 Enterprise Edition
-------------------
DISABLED
ENABLED
Note: DISABLED is set at the factory by default.
(2) Hyper-Threading mode
For the OS supporting the Hyper-Threading mode, you can enable or disable the
Hyper-Threading mode.
Refer to the relevant OS manual to know if the OS supports the Hyper-Threading mode.
DISABLED is set at the factory by default.
Confirmation and setting:
Select EFI System Configuration Menu from the EFI Boot Manager.
↓
Select Processor Configuration.
↓
The screen below appears.
View Hyper Threading Technology.
When the set value does not correspond to the OS, change it to a correct value.
↓
Select Exit, save the change, and reboot the OS to validate the change.
E F I Syst em Con figu ra tion Men u
P r ocessor Con figu ration
CP U F a m ily
: In tel(R) It a n iu m (R) 2
CP U Rev
: C0
Nu m ber of P h ysica l CP U s
Nu m ber of Logica l CP Us
Speed
: 2
: 8
: 1600MH z
L3 Ca ch e Size
: 18MB
BSP In for m a t ion
: CE LL0/CNX00/P ROC01
: LID[0xXXXXXXXXXXXXXXXX]
: CE LL0/CNX00
Ma st er Cell In for m ation
H yper Th rea din g Tech n ology
: [E N ABLE D]
H elp
E xit
3-33
855-900549
Download from Www.Somanuals.com. All Manuals Search And Download.
Operation Procedure
3.6.
System Dump
The system dump can be produced by following the procedure explained below if the OS is
corrupt (e.g., OS stall), or OS information needs to be collected. Note that this operation requires
the OS to be active. System dump cannot be produced if the trouble involves hardware failure
(e.g., HDD containing the OS crashed).
* To produce system dump, OS settings/disk configuration that allow system dump are required.
Some OS does not support system dump. For system dump settings, refer to the
installation/setup manual of each OS.
System dump procedure
(1) Open the SP console, and check that the SP console prompt is present.
(2) Enter SP command “dp,” specify the partition number to produce dump, and enter “yes” (for
the “dp” command, see 2.4.6.3).
(3) After logs of the processors in the selected partition are collected, the OS starts the dump
operation.
(4) After finishing the dump operation, the OS reboots. Log in the OS again and check the dump
file.
* For the location of the system dump file (directory), refer to the installation/setup manual of
the OS.
855-900549
3-34
Download from Www.Somanuals.com. All Manuals Search And Download.
Troubleshooting
Chapter 4
Troubleshooting
This chapter shows general actions to errors in the base module and peripheral units. If a
particular error persists to occur despite the actions you have taken, record the error state and
contact the maintenance personnel of NEC. See Section 1.1 for the mounting image of the base
module components, and Section 2.2 for the external view of the cabinet.
4.1.
Troubleshooting
(1) Power is not supplied when the AC switch on the switch panel at the front top of the cabinet
is turned on.
• Check that the distribution board is turned on.
• Check that AC power is connected to the base module.
• Check that the AC switches for POWBAY#0 and POWBAY#1 are on.
• Check that power cables are connected to POWER BAY#0 and POWER BAY#1.
• Check that the DPSs are mounted on POWER BAY#0 and POWER BAY#1, and
operate normally.
• Note that the switch panel is not used in principle when the UPS is connected.
(2) Nothing is displayed on the SP console.
• Check that the SP console is turned on.
• Check that the iSP card and the SP console in the cabinet are connected properly.
- Is the right cable used?
- Are the connectors firmly inserted?
- Is the IP address set correctly?
• Check that the software does not disable screen display by moving the cursor and
pressing the SHIFT key on the screen.
• Check that the console brightness is set to the proper level.
(3) Nothing is displayed on the VGA console (when the VGA is mounted).
• Check that the VGA console is turned on.
• Check that the VGA card on the I/O module and the VGA console are connected
properly.
- Is the right cable used?
- Are the connectors firmly inserted?
• Check that the software does not disable screen display by moving the cursor and
4-1
855-900549
Download from Www.Somanuals.com. All Manuals Search And Download.
Troubleshooting
pressing the SHIFT key on the screen.
• Check that the VGA console brightness is set to the proper level.
(4) Console commands cannot be entered.
• Check that the keyboard and mouse are connected properly.
• Check that the keyboard and mouse are connected to the I/O module properly.
- Are the right cables used?
- Are the connectors firmly inserted?
(5) The OS does not boot.
• Check that the Power LED of each package turns on.
• Check that the SP console does not display errors.
• When the OS is booted from the DVD-ROM unit on the I/O module, check that
DVD-ROM/CD-ROM unit is connected properly.
• When the OS is booted from the DAT unit on the I/O module, check that the digital audio
tape is loaded correctly.
• When the OS is booted from the HDD on the I/O module (core module), check that the
HDD is connected properly.
(6) The DVD-ROM/CD-ROM medium cannot be read.
• Check that the orange LED on the DVD-ROM unit lights.
• Check that the medium is loaded on the DVD-ROM unit properly.
• Check that data is saved on the medium properly.
- Use more than one medium for confirmation.
• Check that the DVD-ROM unit operates normally.
(7) The digital audio tape cannot be read.
• Check that the green LED on the DAT unit lights.
• Check that data is saved on the digital audio tape properly.
- Use more than one tape for confirmation.
• Check that the DAT unit operates normally.
(8) The system does not recognize the SCSI or HDD.
• Check the settings in BIOS Setup.
855-900549
4-2
Download from Www.Somanuals.com. All Manuals Search And Download.
Notes on Handling
Chapter 5
Notes on Handling
5.1.
Transportation
When the product is transported, pack it with the packing materials used at the time of delivery.
Be sure to turn off the power before moving or packing the product.
5.2.
DVD-ROM/CD-ROM
(1) Do not touch the recording surface (the surface with nothing printed).
(2) Press the center of the case to take the medium out.
(3) Put the medium carefully on the tray with the printed surface facing up.
(4) Do not put anything on the DVD-ROM/CD-ROM or bend it.
(5) Do not attach labels on the medium.
(6) Do not scratch the surface or write letters.
(7) Be careful not to drop the medium. Strong impacts will damage the medium.
(8) Wipe finger marks and dust on the surface with soft cloth from the inner to the outer
portion.
(9) Use a DVD/CD cleaner for cleaning DVD/CD.
Do not use spray or liquid cleaners for vinyl records, benzines, thinners and other chemical
agents.
(10) Do not operate or store the medium at dusty places.
(11) Do not put the medium at places exposed to direct sunlight or excessive heat (e.g., near a
heater).
(12) Put the medium in the case when it is not used.
(13) Keep the CD-ROM attached to the product in a safe place.
If you lost the CD-ROM, contact the maintenance or sales personnel of NEC.
5.3.
Digital Audio Tape
(1) Do not use damaged or deformed digital audio tape.
(2) Do not touch the tape or turn the roller.
(3) Protect the tape from exposure to sources of magnetism. Otherwise, data may be
destroyed.
(4) Do not put the tape at places exposed to direct sunlight or excessive heat (e.g., near a
heater).
(5) Do not give strong impacts or shocks to the tape.
(6) Put the tape in the case when it is not used.
5-1
855-900549
Download from Www.Somanuals.com. All Manuals Search And Download.
Notes on Handling
5.4.
Cleaning
• Wipe the surface of the main and peripheral units with soft cloth.
• Take out the power plug of the main and peripheral units from outlets prior to cleaning.
• Do not use detergents containing polishing materials, cleaning solvents, thinners and other
chemical agents.
• Remove the top cover and clean the parts like air filters using a vacuum cleaner during
inspection or parts replacement.
Front View
Figure 5-1 Cleaning Locations
855-900549
5-2
Download from Www.Somanuals.com. All Manuals Search And Download.
Notes on Handling
5.5.
Notes on Installation
• Do not put things on the cabinet. It does not have safety measures to prevent things put on
the cabinet from falling down.
• Do not block the exhaust vent at the top of the cabinet.
• Provide 50cm of ventilation space above the exhaust vent.
• Provide 1m clearance on the front and rear of the cabinet for maintenance. Also keep 60cm
clearance at both sides of the cabinet as maintenance area.
• In Japan, connect the product to a 30A overcurrent protector for indoor wiring in compliance
with the Electrical Appliance and Material Control Law. Overseas, connect the product to a
30A overcurrent protector in accordance with the relevant electric wiring laws and
regulations.
Do not put things on the cabinet to prevent injury by the objects
falling down the cabinet.
CAUTION
5-3
855-900549
Download from Www.Somanuals.com. All Manuals Search And Download.
Notes on Handling
----- Memo -----
855-900549
5-4
Download from Www.Somanuals.com. All Manuals Search And Download.
|
Mr Coffee Ice Tea Maker TM50 User Manual
Multiquip Saw SP118 User Manual
Multiquip Water Pump qp402h User Manual
Multi Tech Systems Network Card MT5600BR V92 User Manual
Multi Tech Systems Network Card MT5634ZPX PCI U NV User Manual
NEC Flat Panel Television PX 42XM4A User Manual
NETGEAR Network Router WNR2000v2 User Manual
Nexgrill Gas Grill 720 0600 User Manual
Nortel Networks Switch 8010co User Manual
Panasonic Answering Machine KXTG4321 User Manual