Industrial Remote Access Server Installation Guide  
102RAS  
The N-TRON 102RAS provides connectivity to an industrial LAN for telecommuters or mobile  
users, or to remotely installed equipment, via an integrated V.92/56K modem. The small size of the  
102RAS makes it ideal for placing alongside other industrial equipment to be accessed remotely.  
Product Features  
LAN Port: 10/100BaseT; RJ-45  
WAN Port: V92/56K modem; RJ-11  
Rates:  
Data: V.92/56K downloads and 48K upload speeds from V.92 servers; V.90/56K downloads from  
V.90/K56flex servers; 33.6K bps transfers with other servers.  
Standards:  
Data: V.92, V.90, enhanced V.34 and below  
Error Correction: V.42  
Data Compression: V.44, V.42bis, MNP Class 5  
Security  
Local database or RADIUS support  
Callback security (local database only)  
Redundant Power Inputs (10-30 VDC)  
Housed in a ruggedized DIN rail enclosure, designed to withstand the most demanding industrial  
applications, and have been fully tested and certified at industrial environmental extremes  
Web Browser Configuration  
(Revised 2010-11-15)  
page 3 of 30  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Copyright, © N-Tron Corp., 2008  
820 S. University Blvd., Suite 4E  
Mobile, AL 36609  
USA  
All rights reserved. Reproduction, adaptation, or translation without prior written permission from N-Tron  
Corp. is prohibited, except as allowed under copyright laws.  
Ethernet is a registered trademark of Xerox Corporation. All other product names, company names, logos  
or other designations mentioned herein are trademarks of their respective owners.  
The information contained in this document is subject to change without notice. N-Tron Corp. makes no  
warranty of any kind with regard to this material, including, but not limited to, the implied warranties of  
merchantability or fitness for a particular purpose. In no event shall N-Tron Corp. be liable for any  
incidental, special, indirect or consequential damages whatsoever included but not limited to lost profits  
arising out of errors or omissions in this manual or the information contained herein.  
WARNING  
Do not perform any services on the unit unless qualified to do so. Do not substitute unauthorized parts or  
make unauthorized modifications to the unit.  
Do not operate the unit with the top cover removed, as this could create a shock or fire hazard.  
Do not block the air vents on the top of the unit.  
Do not operate the equipment in the presence of flammable gasses or fumes. Operating electrical equipment  
in such an environment constitutes a definite safety hazard.  
Do not operate the equipment in a manner not specified by this manual.  
General Safety Warnings  
WARNING: If the equipment is used in the manner not specified by N-Tron Corp., the protection  
provided by the equipment may be impaired.  
Contact Information  
N-Tron Corp.  
820 South University Blvd. Suite 4E  
Mobile, AL 36609  
TEL: (251) 342-2164  
FAX: (251) 342-6353  
(Revised 2010-11-15)  
page 4 of 30  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Environmental Safety  
WARNING: Disconnect the power and allow to cool 5 minutes before touching.  
Electrical Safety  
WARNING: Disconnect the power cable before removing any modules, or any enclosure panel.  
WARNING: Do not operate the unit with the cover removed.  
WARNING: Properly ground the unit before connecting anything else to the unit. Units not properly  
grounded may result in a safety risk and could be hazardous and may void the warranty. See the grounding  
technique section of this user manual for proper ways to ground the unit.  
WARNING: Do not work on equipment or cables during periods of lightning activity.  
WARNING: Do not perform any services on the unit unless qualified to do so.  
WARNING: Do not operate the equipment in the presence of flammable gasses or fumes. Operating  
electrical equipment in such an environment constitutes a definite safety hazard.  
WARNING: Do not block the air vents.  
WARNING: Observe proper DC Voltage polarity when installing power input cables. Reversing voltage  
polarity can cause permanent damage to the unit and void the warranty.  
Hazardous Location Installation Requirements  
1. WARNING: Explosion hazard Do not replace the device unless power has been switched off or the  
area is known to be non-hazardous.  
2. WARNING: Explosion hazard. Do not disconnect while the circuit is live or unless the area is known  
to be non-hazardous.  
3. WARNING: Install only in accordance with Local & National Codes of Authorities Having  
Jurisdiction.  
4. WARNING: Explosion Hazard - Substitution of components may impair suitability for Class I,  
Division 2.  
(Revised 2010-11-15)  
page 5 of 30  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
5. Class I, Div 2 Installations require that power connections must be current limited at the power source  
with an in-line fuse rated at 0.5A.  
6. Class I, Div 2 installations require that all devices connected to this product must be UL listed for the  
area in which it is installed.  
7. Use 60/75ºC rated Copper wire, (022Nm) 2 inch-lbs Tightening torque for field installed connectors.  
8. Limited Operating Voltage: 10-30V for Class I, Div 2 installations.  
9. This apparatus is suitable for use in Class I, Div 2, Groups A, B, C, and D, or unclassified or  
nonhazardous locations only.  
Package Contents  
Please make sure the 102RAS Remote Access Server package contains the following items:  
1. 102RAS Remote Access Server  
2. Product CD  
Contact your carrier if any items are damaged.  
Installation  
Read the following warning before beginning the installation:  
WARNING  
Never install or work on electrical equipment or cabling during periods of lightning activity. Never connect  
or disconnect power when hazardous gasses are present.  
Disconnect the power cable before removing any enclosure panel.  
Do not operate the unit with any covers removed  
Unpacking  
Remove all the equipment from the packaging, and store the packaging in a safe place. File any damage  
claims with the carrier.  
Cleaning  
Clean only with a damp cloth.  
(Revised 2010-11-15)  
page 6 of 30  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
DIN Rail Mounting  
Install the unit on a standard 35mm DIN rail. Recess the unit to allow at least 3” of horizontal clearance for  
cable bend radius.  
To mount the unit to the 35mm DIN rail,  
To remove the unit from the 35mm DIN rail, typically  
place top edge of the brackets on the back of the it is possible to remove the unit by using your index and  
unit against the DIN rail at a 45° upward angle. middle fingers or use flat head screwdrivers placed into  
Lower the bottom of the unit until it snaps into each of the release clips at the bottom of the unit to push  
place on each bracket.  
down on each clip until they disengage the bottom of the  
unit from the DIN rail. Lift the bottom of the unit up at  
an approximate 45° upward angle to completely remove  
the unit.  
Most N-Tron™ products are  
designed to be mounted on industry  
standard 35mm DIN rail. However,  
DIN rail mounting may not be  
suitable for all applications. Our  
Universal Rack Mount Kit (P/N:  
URMK) may be used to mount the  
102RAS to standard 19" racks as an  
option.  
(Revised 2010-11-15)  
page 7 of 30  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Front Panel  
From Top to Bottom:  
Green LED lights when Power is supplied to the module  
RJ-45 Port  
RJ-11 Port  
TR  
Auto sensing 10/100 Base-TX Connection  
Phone line connection  
Transmit Ready  
CD  
Carrier Detect  
TX  
Transmit  
RX  
Receive  
Note: The RJ45 data port has two LED’s located at the side of the connector. The bottom LED indicates  
LINK status, and the top LED indicates ACTIVITY.  
LED’s: The table below describes the operating modes:  
LED Description  
Lit when Power is applied.  
Lit when 10/100 Mb Link between ports exists.  
Lit when data is active between ports.  
LNK  
ACT  
TR  
Lit when 102RAS modem is ready to answer.  
Lit when carrier is detected by 102RAS.  
Lit when data is being transmitted by 102RAS.  
Lit when data is being received by 102RAS.  
CD  
TX  
RX  
Phone Interface  
The 102RAS provides an RJ-11 phone line interface to connect to a standard wall outlet.  
(Revised 2010-11-15)  
page 8 of 30  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Applying Power (Top View)  
Remove Supplied #6 Phillips head grounding screw from top of unit.  
Connect ground wire with lug (not supplied) and re-install the grounding screw securely.  
Unscrew & Remove the DC Voltage Input Plug from the Power Input Header  
Install the DC Power Cables into the Plug (observing polarity).  
Plug the Voltage Input Plug back into the Power Input Header.  
Tightening torque for the terminal block power plug is 0.22 Nm/0.162 Pound Foot.  
Verify the Power LED stays ON (GREEN).  
Note: Only 1 power supply must be connected to power for minimal operation. For redundant power  
operation, V1 and V2 inputs must be connected to separate DC Voltage sources. This device draws current  
from both sources simultaneously. Use 16-28 gauge wire when connecting to the power supply.  
Recommended 24V DC Power Supplies, similar to: N-Tron’s P/N NTPS-24-1.3, 24VDC at 1.3A  
(Revised 2010-11-15)  
page 9 of 30  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
N-TRON SWITCH GROUNDING TECHNIQUES  
The grounding philosophy of any control system is an integral part of the design. N-Tron switches are  
designed to be grounded, but the user has been given the flexibility to float the switch when required. The  
best noise immunity and emissions (i.e. CE) are obtained when the N-Tron switch chassis is connected to  
earth ground via a drain wire. Some N-Tron switches have metal din-rail brackets that can ground the  
switch if the din-rail is grounded. In some cases, N-Tron switches with metal brackets can be supplied with  
optional plastic brackets if isolation is required.  
Both V- legs of the power input connector are connected  
to chassis internally on the PCB. Connecting a drain wire  
to earth ground from one of the V- terminal plugs as  
shown here will ground the switch and the chassis. The  
power leads from the power source should be limited to 3  
meters or less in length.  
As an alternate, users can run a drain wire & lug from any of the Din-  
Rail screws or empty PEM nuts on the enclosure. When using an  
unused PEM nut to connect a ground lug via a machine screw, care  
should be taken to limit the penetration of the outer skin by less than 1/4  
in. Failure to do so may cause irreversible damage to the internal  
components of the switch.  
Note: Before applying power to the grounded switch, you must use a  
volt meter to verify there is no voltage difference between the power  
supply’s negative output terminal and the switch chassis grounding  
point.  
If the use of shielded cables is required, it is generally recommended to only connect the shield at one end to  
prevent ground loops and interfere with low level signals (i.e. thermocouples, RTD, etc.). Cat5e cables  
manufactured to EIA-568A or 568B specifications are required for use with N-Tron Switches.  
In the event all Cat5e patch cable distances are small (i.e. All Ethernet devices are located the same local  
cabinet and/or referenced to the same earth ground), it is permissible to use fully shielded cables terminated  
to chassis ground at both ends in systems void of low level analog signals.  
(Revised 2010-11-15)  
page 10 of 30  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RJ45 CONNECTOR CRIMP SPECIFICATIONS  
Please reference the illustration below for your Cat5 cable specifications:  
(Revised 2010-11-15)  
page 11 of 30  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Overview of Features  
Compact Remote Access Solution  
The 102RAS includes one integrated V.92/56K modem, housed in a compact, industrial chassis which  
provides V.92/56K download speeds and 48K upload speeds when connecting with V.92 servers. Dial-in  
users can achieve V.34/33.6K connections. Unit ships with 35mm DIN rail connector suitable for mounting  
the unit on 35mm DIN rail in industrial environment.  
Secure Remote Access  
The 102RAS has a built-in security database for user name and password authentication for all remote users.  
It also has a built-in RADIUS client for authentication to a RADIUS server.  
Callback Security  
The 102RAS provides password protection with callback security, and helps reduce long distance charges,  
for remote offices and users requiring access to the central site LAN. The 102RAS server supports three  
security options. The “fixed” callback option stores a password and the remote user’s phone number. Once  
the remote site enters their password, the 102RAS calls back using the number stored in its database. The  
“variable” option lets the user enter a fixed password and a variable call back number each time they call.  
The “pass through” option is used to provide the security of password protection, while bypassing the call  
back process.  
Configuration and Management  
The 102RAS web interface provides for easy set-up and configuration. In addition, it provides the ability to  
view the current line status as well as a history of past activity.  
Note: N-Tron does not provide technical support for the below Shared Modem Usage using Third  
Party software (N-Tron does not provide any software for this use).  
Shared Dial-Out Convenience  
The 102RAS can also provide dial-out support for PC users on IP. This means system administrators no  
longer have to dedicate a modem for LAN users who need to access information services. When used in  
Modem Sharing mode, computers with network access to the 102RAS can use Telnet on port 7000 and get  
direct access to the modem in the 102RAS. More commonly a com port redirector can be installed on the  
workstation(s). A redirector adds a virtual communication port to Windows and uses Telnet to map  
(redirect) the com port to the modem. Communication programs using this virtual com port will have its  
data redirected to and from the modem within the 102RAS, eliminating the need for each workstation to  
have its own modem and phone line. Only one com port (telnet session) can be open at a time.  
(Revised 2010-11-15)  
page 12 of 30  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Troubleshooting  
1.  
2.  
Make sure the (Power LED) is ON.  
Make sure you are supplying sufficient current. Note: The Inrush current will exceed the  
steady state current by ~ 2X.  
3.  
4.  
5.  
6.  
Verify that Link LED’s are ON for connected ports.  
Verify cabling used between stations.  
Verify the phone socket that the phone line from the 102RAS is plugged into is operational.  
Verify that cabling is Category 5E or greater for 100Mbit Operation.  
Support:  
Contact N-Tron Corp. at:  
TEL: 251-342-2164  
FAX: 251-342-6353  
(Revised 2010-11-15)  
page 13 of 30  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Regulatory Statements  
47 CFR Part 15 Regulation  
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:  
(1) this device may not cause harmful interference, and (2) this device must accept any interference  
received, including interference that may cause undesired operation.  
Industry Canada  
This Class A digital apparatus complies with Canadian ICES-003.  
Cet appareil numérique de la classe A est conforme à la norme NMB-o003 du Canada.  
47 CFR Part 68 Telecom  
1. This equipment complies with Part 68 of the 47 CFR rules and the requirements adopted by the  
ACTA. Located on this equipment is a label that contains, among other information, the registration  
Number and ringer equivalence number (REN) for this equipment or a product identifier in the  
format:  
For current products is US:AAAEQ##Txxxx.  
For legacy products is AU7USA-xxxxx-xx-x.  
If requested, this number must be provided to the telephone company.  
2. A plug and jack used to connect this equipment to the premises wiring and telephone network must  
comply with the applicable 47 CFR Part 68 rules and requirements adopted by the ACTA. It’s  
designed to be connected to a compatible modular jack that is also compliant.  
3. The ringer equivalence number (REN) is used to determine the number of Devices that may be  
connected to a telephone line. Excessive RENs on a telephone line may result in the Devices not  
ringing in response to an incoming call. In most but not all areas, the sum of RENs should not  
exceed five (5.0). To be certain of the number of Devices that may be connected to a line, as  
determined by the total RENs, contact the local telephone company. For products approved after  
July 23, 2001, the REN for this product is part of the product identifier that has the format  
US:AAAEQ##Txxxx. The digits represented by ## are the REN without a decimal point (e.g., 03 is  
a REN of 0.3). For earlier products, the REN is separately shown on the label.  
4. If this equipment causes harm to the telephone network, the telephone company will notify you in  
advance that temporary discontinuance of service may be required. But if advance notice isn't  
practical, the telephone company will notify the customer as soon as possible. Also, you will be  
advised of your right to file a complaint with the FCC if you believe it is necessary.  
5. The telephone company may make changes in its facilities, equipment, operations or procedures that  
could affect the operation of the equipment. If this happens, the telephone company will provide  
advance notice in order for you to make necessary modifications to maintain uninterrupted service.  
6. If trouble is experienced with this equipment, please contact N-Tron Corp. at the address shown  
below for details of how to have the repairs made. If the equipment is causing harm to the telephone  
network, the telephone company may request that you disconnect the equipment until the problem is  
resolved.  
7. Connection to party line service is subject to state tariffs. Contact the state public utility  
commission, public service commission or corporation commission for information.  
8. No repairs are to be made by you. Repairs are to be made only by N-Tron Corp. or its licensees.  
Unauthorized repairs void registration and warranty.  
(Revised 2010-11-15)  
page 14 of 30  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
9. If your home or office has specially wired alarm equipment connected to the telephone line, ensure  
the installation of this equipment does not disable your alarm equipment. If you have questions  
about what will disable alarm equipment, consult your telephone company or a qualified installer.  
10. This equipment is hearing aid compatible.  
11. Manufacturing Information:  
Manufacturer:  
Trade Name:  
N-Tron Corp.  
102RAS  
Model Number:  
102RAS  
Registration No:  
Ringer Equivalence:  
Modular Jack (USOC):  
Service Center in USA:  
AU7USA-25814-M5-E  
0.3B  
RJ11  
N-Tron Corp.  
820 South University Blvd. Suite 4E  
Mobile, AL 36609  
U.S.A.  
(251) 342-2164  
(251) 342-6353 Fax  
Canadian Limitations Notice  
Notice: The ringer equivalence number (REN) assigned to each terminal Device provides an indication of  
the maximum number of terminals allowed to be connected to a telephone interface. The termination on an  
interface may consist of any combination of Devices subject only to the requirement that the sum of the  
ringer equivalence numbers of all the Devices does not exceed 5.  
Notice: The Industry Canada label identifies certified equipment. This certification means that the  
equipment meets certain telecommunications network protective, operational, and safety requirements.  
The Industry Canada label does not guarantee the equipment will operate to the user’s satisfaction.  
Before installing this equipment, users should ensure that it is permissible to be connected to the facilities of  
the local telecommunications company. The equipment must also be installed using an acceptable method of  
connection. The customer should be aware that compliance with the above conditions may not prevent  
degradation of service in some situations. Repairs to certified equipment should be made by an authorized  
Canadian maintenance facility designated by the supplier. Any repairs or alterations made by the user to this  
equipment or equipment malfunctions may give the telecommunications company cause to request the user  
to disconnect the equipment.  
Users should ensure for their own protection that the electrical ground connections of the power utility,  
telephone lines and internal metallic water pipe system, if present, are connected together. This precaution  
may be particularly important in rural areas.  
Caution: Users should not attempt to make such connections themselves, but should contact the appropriate  
electric inspection authority, or electrician, as appropriate.  
New Zealand Telecom Warning Notice  
1. The grant of a Telepermit for any item of terminal equipment indicates only that Telecom has accepted  
that the item complies with minimum conditions for connection to its network. It indicates no endorsement  
of the product by Telecom, nor does it provide any sort of warranty. Above all, it provides no assurance that  
any item will work correctly in all respects with another item of Telepermitted equipment of a different  
make or model, nor does it imply that any product is compatible with all of Telecom’s network services.  
This equipment is not capable under all operating conditions of correct operating conditions of correct  
operation at the higher speed which it is designated. 33.6 kbps and 56 kbps connections are likely to be  
(Revised 2010-11-15)  
page 15 of 30  
Download from Www.Somanuals.com. All Manuals Search And Download.  
restricted to lower bit rates when connected to some PSTN implementations. Telecom will accept no  
responsibility should difficulties arise in such circumstances.  
2. Immediately disconnect this equipment should it become physically damaged, and arrange for its  
disposal or repair.  
3. This modem shall not be used in any manner which could constitute a nuisance to other Telecom  
customers.  
4. This device is equipped with pulse dialing, while the Telecom standard is DTMF tone dialing. There is  
no guarantee that Telecom lines will always continue to support pulse dialing.  
Use of pulse dialing, when this equipment is connected to the same line as other equipment, may give rise to  
'bell tinkle' or noise and may also cause a false answer condition. Should such problems occur, the user  
should NOT contact the Telecom Faults Service.  
The preferred method of dialing is to use DTMF tones, as this is faster than pulse (decadic) dialing and is  
readily available on almost all New Zealand telephone exchanges.  
5. Warning Notice: No '111' or other calls can be made from this device during a mains power failure.  
6. This equipment may not provide for the effective hand-over of a call to another device connected to the  
same line.  
7. Some parameters required for compliance with Telecom’s Telepermit requirements are dependent on the  
equipment (PC) associated with this device. The associated equipment shall be set to operate within the  
following limits for compliance with Telecom’s Specifications:  
For repeat calls to the same number:  
There shall be no more than 10 call attempts to the same number within any 30 minute period for any  
single manual call initiation, and  
The equipment shall go on-hook for a period of not less than 30 seconds between the end of one attempt  
and the beginning of the next attempt.  
For automatic calls to different numbers:  
The equipment shall be set to ensure that automatic calls to different numbers are spaced such that there is  
no less than 5 seconds between the end of one call attempt and the beginning of another.  
8. For correct operation, total of the RN’s of all devices connected to a single line at any time should not  
exceed 5.  
South African Statement  
This modem must be used in conjunction with an approved surge protection device.  
Telecom Approvals for the Embedded Modem Model Number 5634SMI  
Country  
Status  
Approval Number  
Argentina  
Australia  
Austria  
Belgium  
Brazil  
Approved  
Approved  
Approved  
Approved  
Approved  
Approved  
Approved  
CNC 54-4936  
ACN092448710  
CE  
CE  
ANATEL 0214-03-1845  
125-10317A  
SUBTEL 3672  
Canada  
Chile  
(Revised 2010-11-15)  
page 16 of 30  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
China  
China NALTE  
Cyprus  
Czech Republic  
Denmark  
Estonia  
Approved  
Approved  
Approved  
Approved  
Approved  
Approved  
Approved  
Approved  
Approved  
Approved  
Approved  
Approved  
Approved  
Approved  
Approved  
Approved  
Approved  
Approved  
Approved  
Approved  
Approved  
Approved  
Approved  
Approved  
Approved  
Approved  
Approved  
Approved  
Approved  
Approved  
Approved  
Approved  
20650004500320  
10-6066-060989  
CE  
CE  
CE  
CE  
CE  
CE  
CE  
CE  
Finland  
France  
Germany  
Greece  
Hong Kong  
Hungary  
Iceland  
India  
Indonesia  
Ireland  
Israel  
Italy  
Japan  
Korea  
SL 300063  
CE  
CE  
TEC/NR/I/MOD-08/01/082.JUL03  
01144/1/POSTEL/2003  
CE  
13-12323-0-103246-07/06  
CE  
AD04-0451001  
TE-A22/K012-04-0357  
Latvia  
CE  
CE  
CE  
CE  
Liechtenstein  
Lithuania  
Luxembourg  
Malta  
CE  
Mexico  
COFETEL:TTDMUMT021-411  
Netherlands  
New Zealand  
Norway  
Philippines  
Poland  
CE  
PTC 0211/00/095 RN=0.5  
CE  
ESD-CPE-04000628  
CE  
CE  
Portugal  
Russia Telecom  
Approved  
д-TOP-0120  
Russia Safety  
Singapore  
Slovakia  
Slovenia  
South Africa  
Spain  
Sweden  
Switzerland  
Taiwan  
Turkey  
United Kingdom  
United States  
Approved  
Approved  
Approved  
Approved  
Approved  
Approved  
Approved  
Approved  
Approved  
Approved  
Approved  
Approved  
Mл05  
DB-00626  
CE  
CE  
TE-2002/121  
CE  
CE  
CE  
B93-M007-F  
AG/UM-2001.235  
CE  
AU7USA-25814-M5-E REN:03B  
(Revised 2010-11-15)  
page 17 of 30  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Software Configuration  
Web Management  
Enter the switch’s IP address in any web browser and login to the web management feature of the  
102RAS.  
Default:  
Username: admin  
Password: admin  
(Revised 2010-11-15)  
page 18 of 30  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Web Management - Home  
When the administrator first logs onto the 102RAS, the default home page is displayed. At the top  
of the screen there is a list of configurable settings which the 102RAS supports. This section of the manual  
will go through each choice listed at the top of the screen and explain how to configure those settings. In  
the center of the main home page the administrator/user can see some basic information like what firmware  
revision the 102RAS is running.  
(Revised 2010-11-15)  
page 19 of 30  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Web Management Menu Structure  
Home  
Shows information about the manufacturer and the 102RAS, along with support Website and E-Mail  
addresses.  
Login  
Brings up the Login page  
Logout  
Logs off the current user  
Administration  
IP Configuration  
Shows the current IP Configuration and allows User to change.  
SMTP Configuration Shows the current SMTP Configuration and allows User to change.  
Time Configuration Shows the current Time Configuration and allows User to change.  
Reset Unit  
Resets the 102RAS.  
Local Users  
Shows information about the Local User Database, and allows User to modify.  
Call Log  
Log Parameters  
Shows the current Logging Configuration and allows User to change.  
Call Log  
Shows the Call Log and allows User to select details for any call.  
Current Status  
System  
Shows the status of the 102RAS.  
POTS Modem 1  
Shows the status of the embedded Modem.  
Modem Setup  
Modem Setup  
General Modem Setup  
Shows the current Modem Configuration and allows User to change.  
Shows the general Modem Configuration and allows User to change.  
Authentication  
Authentication Setup Shows the current Authentication Configuration and allows User to  
change.  
Radius Client Setup Shows the current Radius Client Configuration and allows User to change.  
(Revised 2010-11-15)  
page 20 of 30  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Administration IP Configuration  
The IP Configuration part of the Administration page lists the following information about the 102RAS:  
IP Address  
Subnet Mask  
Default Gateway  
Name Server  
Secondary Name Server  
You may change the values to apply to your network and select the update button to save the values. The  
fields for “IP Address”, “Subnet Mask”, “Default Gateway” and “Name Server” are required. A  
“Secondary Name Server” is optional.  
Administration SMTP Configuration  
The SMTP Configuration part of the Administration page lists the following information about the 102RAS:  
SMTP Server Address  
SMTP Port  
Administrator E-Mail  
SMTP Password  
From here you can setup the Mail Server by following the following steps:  
1) A mail server in the “SMTP Server Address” field.  
2) The E-Mail address of the Administrator in the Administrator E-Mail” field.  
3) If the SMTP Server requires a User ID, enter the ID in the “SMTP Server User ID” field.  
4) If the SMTP Server requires a password, enter the password in the “SMTP Password” field.  
5) If you enter a password, retype the identical password in the “Retype SMTP Password” field  
6) Click on Update. At this point the 102RAS will send the Administrator an e-mail saying that the  
mail server has been updated.  
(Revised 2010-11-15)  
page 21 of 30  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Administration Time Configuration  
The Time Configuration part of the Administration page lists the following information about the 102RAS:  
Time Server  
Request Interval  
Time Zone  
Date Format  
Time Format  
From here you can set the time configuration used for time stamping on the 102RAS. You can make  
modifications then click the update button to save the new configuration.  
Note: By default, the 102RAS receives the date and time via Time Server via an internet connection.  
In the event the Local LAN (where the 102RAS is installed) does not have access to the internet, you  
must enter the IP Address of a Server on the Local LAN that has a Network Time Protocol (NTP)  
service enabled in order to have correct date and time recorded in the log.  
Administration Reset Unit  
From here the Administrator can remotely reset the 102RAS by clicking on the reset button.  
Local Users  
This page shows the local database stored on the 102RAS, and lists the following items:  
Name  
User ID  
Password  
Callback  
Callback#  
(Revised 2010-11-15)  
page 22 of 30  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
From here, the Administrator’s Name, User ID and Password can be changed. Also, Local users may be  
added by filling out a new row and selecting the add button. Once Local users have been added, a user can  
be removed by selecting the delete button and can be updated by changing the information and selecting the  
update button.  
Callback Security Options:  
1) Administrator:  
If the Callback Security option is enabled and Admin specified is selected, then enter your fixed  
callback telephone number in the Callback # window. If the Callback Security option is enabled and User  
Specified is selected, you do not enter a telephone number in the Callback # window. You enter the  
callback telephone number during the dial-in process.  
2) Remote user:  
If you are going to enable the Callback Security option, click on the Callback down arrow and  
choose the callback method. A fixed phone number is Admin specified or a variable phone number is User  
specified. For example, if a traveling sales person needs to be called back at their current location, they will  
provide the callback telephone number during the dial-in process.  
If the Callback Security option is enabled and Admin specified is selected, then enter their fixed  
callback telephone number in the Callback # window. If the Callback Security option is enabled and User  
specified is selected, you do not enter a telephone in the callback # window. The remote user enters the  
callback number during the dial-in process.  
Note: The first row is for the “Administrator” function. No matter what values are used for the Name,  
User ID and Password fields, the first row will apply to the person doing the Administrator function  
for the 102RAS. The Administrator is the party privileged to configure the 102RAS.  
Call Log  
The Call Log screen displays the parameters you can set for the Call Log entries and displays a call log  
entry for each call.  
The Log Parameters define the threshold number of entries and the number of entries retained in the log  
history. Both Auto Log Threshold and Log History can be set to a maximum of 20 entries by filling in the  
field and clicking on Save Changes. The log can be E-Mailed to the Administrator address by clicking on  
Send Log Now and the Log can be deleted by clicking on Delete Log.  
The Call Log summarizes each call and the Details button displays an in-depth look at the call from the  
individual initiating the call, when the call was connected, duration of the call, transmit and receive baud  
rates, to authentication status.  
(Revised 2010-11-15)  
page 23 of 30  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Current Status - System  
This page shows the Current System Status of the 102RAS and shows the following values:  
Current Time  
Up Time  
Pending Messages  
Email Status  
Email To  
Subject  
Time Server Status  
Current Time  
- Indicates the present time of day.  
Pending Messages  
- Indicates the number of e-mails sent to the administrator that have not been opened.  
These can include debug log messages, mail server change notification messages.  
(relating to the “SMTP Server Address” field of Administration screen).  
- Indicates the Administrator’s address to which e-mails should be sent.  
- Title of the last pending or sent e-mail.  
Email To  
Subject  
Time Server Status - Indicates the status of the Time server which could be “Initializing, No Errors, or  
SNTP Error: type.  
Up Time  
- Operation time since last reboot.  
E-mail Status  
- Indicates whether the 102RAS e-mail transmissions, both calls and administrative  
messages, are proceeding with or without errors, may be one of the following.  
No Errors, Bad MailServer Address, Mail Server Connect Failed,  
SMTP Invalid Response, SMTP Client Timeout”.  
Note: The 102RAS synchronizes its call time stamps to an Internet source, usually a government standards  
site. It will attempt contact with the standards web site 5 times in 20 seconds. If contact fails, it will  
try 5 times again 5 minutes later. If contact succeeds, the 102RAS will update its stamping time  
periodically per an interval set in the Administration screen.  
(Revised 2010-11-15)  
page 24 of 30  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Current Status POTS modem 1  
This page shows the Current Status of the POTS Modem embedded in the 102RAS.  
State  
Connect Time  
Elapsed Time  
State  
- Indicates the modem’s current operating condition which can be one of the following:  
Waiting for Ring, Initializing Modem, Waiting for Connect, User login”,  
“Getting Call Info.  
Connect Time - The date and time at which the connection began for the current call.  
Elapsed Time - The duration of the current call in seconds.  
The Administrator can also initialize the modem by clicking on Initialize Modem, or make the modem go  
off hook by clicking on Make Busy.  
Modem Setup  
This page shows the current Modem configuration of the 102RAS.  
Modem Usage  
Country Code  
Number of rings to answer on  
If you are using the 102RAS for dial-in PPP access (default usage), you do not have to modify the modem  
usage, but you do have to select the Country Code.  
(Revised 2010-11-15)  
page 25 of 30  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Note: The following modem sharing options are available, but N-Tron does not provide technical  
support for using third party software with the 102RAS (N-Tron also does not provide any  
software for this use).  
If you are using your 102RAS for dial-out, you will have to select one of the Modem Sharing options and  
select the Country Code. With any of the Modem Sharing options, the TCP port number used to access the  
modem is 7000. Modem Sharing with authentication means a login prompt will be issued to the socket  
when it is opened. The opener of the socket must provide appropriate credentials before access is given to  
the modem. If RAW is also selected support for RFC 2217 (com port control vial Telnet) will be disabled.  
Modem Sharing No Authentication - Immediate access is given to the modem.  
Modem Sharing Local Authentication - A valid set of credentials, defined in the Local User data base,  
is required before access is granted.  
Modem Sharing Radius Authentication - A valid set of credentials, defined in the Radius User data  
base, is required before access is granted.  
Modem Sharing Raw Mode with No Authentication - User data is treated “as is”, without  
interpretation, and no authentication is required.  
Modem Sharing Raw Mode with Local Authentication - User data is treated “as is”, without  
interpretation, and a valid set of credentials, defined in the Local User data base, is required before access is  
granted.  
Modem Sharing Raw Mode with Radius Authentication - User data is treated “as is”, without  
interpretation, and a set of credentials, defined in the Radius User data base, is required before access is  
granted.  
Caution: Modem sharing is accomplished by implementing a Telnet interface to the 102RAS’s embedded  
modem. Secure the access to the port via a firewall or IP filter settings to prevent unauthorized use of your  
modem resource.  
Authentication  
This page shows the current Authentication configuration of the 102RAS.  
Authentication Setup  
Remote Host Address  
Radius Server Address 1 and Port  
Radius Accounting Address 1 and Port  
Secret  
If your database for user credentials resides in the Local User Database on the 102RAS, then accept the  
default – “local. If your user database resides on a Radius Server, then click on the down arrow and choose  
radius.  
If modem usage is RAS, enter a static IP Address in the Remote Host Address window which will be  
assigned to the dial-in user. This Remote Host Address has to match the network scheme of the 102RAS.  
(Revised 2010-11-15)  
page 26 of 30  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
If you are setting up the 102RAS to use Radius authentication, then:  
1) Enter the IP address of the primary RADIUS Server in the RADIUS Server Address 1 field.  
2) Enter the port number (usually port 1812) for the RADIUS Server in the top Port field.  
3) Enter the IP address of the Radius Accounting server in the RADIUS Accounting Address 1 field.  
4) Enter the port number (usually port 1813) for the Radius Accounting Server in the bottom Port field.  
5) Enter the Secret of the Radius Server that you are communicating with. The Secret has to be  
identical to the one used by your Radius Server.  
(Revised 2010-11-15)  
page 27 of 30  
Download from Www.Somanuals.com. All Manuals Search And Download.  
KEY SPECIFICATIONS  
Physical  
Height:  
Width:  
3.40" (8.64cm)  
1.50" (3.81 cm)  
3.60" (9.14 cm)  
Depth:  
Including DIN-Rail Mount: 4.32” (10.9 cm)  
Weight:  
DIN-Rail:  
0.70 lbs (0.32 kg)  
35mm  
Electrical  
Redundant Input Voltage:  
Input Current:  
Inrush Current:  
Input Ripple:  
10-30 VDC (Regulated)  
221 mA at 24VDC (Steady State)  
7.4 A /0.7 ms at 24VDC  
Less than 100 mV  
Environmental  
Operating Temp:  
Storage Temp:  
-20°C to 70°C  
-40°C to 85°C  
Operating Humidity:  
Operating Altitude:  
10% to 95% (Non Condensing)  
0 to 10,000 ft.  
Shock and Vibration (bulkhead mounting)  
Shock:  
200g @ 10ms  
Vibration/Seismic:  
50g, 5-200Hz, Triaxial  
Reliability  
MTBF:  
>1Million Hours  
Network Media  
10BaseT:  
100BaseTX:  
>Cat3 Cable  
>Cat5 Cable  
Connectors  
10/100BaseTX:  
Phone Line:  
One (1) RJ-45 TX Copper Port  
One (1) RJ-11 Modular Port  
Modem Port  
V.92/56K Modem  
Data: V.92, V.90, enhanced V.34 & below  
Error Correction: V.42  
Data Compression: V.44, MNP Class 5; V.42bis  
Recommended Wiring Clearance:  
Top: 1 " (2.54 cm)  
Front: 2 " (5.08 cm)  
Side: 1” (2.54 cm)  
(Revised 2010-11-15)  
page 28 of 30  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
REGULATORY APPROVALS  
SAFETY: Suitable for use in Class I, Division 2, Groups A, B, C and D Hazardous Locations, or  
Nonhazardous Locations only.  
EMI: EN 55022: 1998 w/A1 & A2, CISPR 22 - Class A  
47 CFR, Part 15, Subpart B - Class A  
47 CFR, Part 68 (Embedded Device Multi-Tech Systems Model: MT5634SMI)  
EMS: EN 55024: 1998 w/A1 & A2  
IEC 61000-4-2 Ed. 1.2 (ESD)  
IEC 61000-4-3 Ed. 2.1 (RS)  
IEC 61000-4-4 2nd Ed. (EFT)  
IEC 61000-4-5 2nd Ed. (Surge)  
IEC 61000-4-6 Ed. 2.1 (Conducted Disturbances)  
GOST-R Certified.  
Warranty: Effective January 1, 2008, all N-TRON products carry a 3 year limited warranty from the date  
of purchase.  
(Revised 2010-11-15)  
page 29 of 30  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
N-TRON Limited Warranty  
N-TRON, Corp. warrants to the end user that this hardware product will be free from defects in workmanship and materials,  
under normal use and service, for the applicable warranty period from the date of purchase from N-TRON or its authorized  
reseller. If a product does not operate as warranted during the applicable warranty period, N-TRON shall, at its option and  
expense, repair the defective product or part, deliver to customer an equivalent product or part to replace the defective item,  
or refund to customer the purchase price paid for the defective product. All products that are replaced will become the  
property of N-TRON. Replacement products may be new or reconditioned. Any replaced or repaired product or part has a  
ninety (90) day warranty or the remainder of the initial warranty period, whichever is longer. N-TRON shall not be  
responsible for any custom software or firmware, configuration information, or memory data of customer contained in, stored  
on, or integrated with any products returned to N-TRON pursuant to any warranty.  
OBTAINING WARRANTY SERVICE: Customer must contact N-TRON within the applicable warranty period to obtain  
warranty service authorization. Dated proof of purchase from N-TRON or its authorized reseller may be required. Products  
returned to N-TRON must be pre-authorized by N-TRON with a Return Material Authorization (RMA) number marked on  
the outside of the package, and sent prepaid and packaged appropriately for safe shipment. Responsibility for loss or damage  
does not transfer to N-TRON until the returned item is received by N-TRON. The repaired or replaced item will be shipped  
to the customer, at N-TRON’s expense, not later than thirty (30) days after N-TRON receives the product. N-TRON shall  
not be responsible for any software, firmware, information, or memory data of customer contained in, stored on, or integrated  
with any products returned to N-TRON for repair, whether under warranty or not.  
ADVANCE REPLACEMENT OPTION: Upon registration, this product qualifies for advance replacement. A replacement  
product will be shipped within three (3) days after verification by N-TRON that the product is considered defective. The  
shipment of advance replacement products is subject to local legal requirements and may not be available in all locations.  
When an advance replacement is provided and customer fails to return the original product to N-TRON within fifteen (15)  
days after shipment of the replacement, N-TRON will charge customer for the replacement product, at list price.  
WARRANTIES EXCLUSIVE: IF AN N-TRON PRODUCT DOES NOT OPERATE AS WARRANTED ABOVE,  
CUSTOMER'S SOLE REMEDY FOR BREACH OF THAT WARRANTY SHALL BE REPAIR, REPLACEMENT, OR  
REFUND OF THE PURCHASE PRICE PAID, AT N-TRON'S OPTION. TO THE FULL EXTENT ALLOWED BY LAW,  
THE FOREGOING WARRANTIES AND REMEDIES ARE EXCLUSIVE AND ARE IN LIEU OF ALL OTHER  
WARRANTIES, TERMS, OR CONDITIONS, EXPRESS OR IMPLIED, EITHER IN FACT OR BY OPERATION OF  
LAW, STATUTORY OR OTHERWISE, INCLUDING WARRANTIES, TERMS, OR CONDITIONS OF  
MERCHANTABILITY,  
FITNESS  
FOR  
A
PARTICULAR  
PURPOSE,  
SATISFACTORY  
QUALITY,  
CORRESPONDENCE WITH DESCRIPTION, AND NON-INFRINGEMENT, ALL OF WHICH ARE EXPRESSLY  
DISCLAIMED. N-TRON NEITHER ASSUMES NOR AUTHORIZES ANY OTHER PERSON TO ASSUME FOR IT  
ANY OTHER LIABILITY IN CONNECTION WITH THE SALE, INSTALLATION, MAINTENANCE OR USE OF ITS  
PRODUCTS. N-TRON SHALL NOT BE LIABLE UNDER THIS WARRANTY IF ITS TESTING AND EXAMINATION  
DISCLOSE THAT THE ALLEGED DEFECT OR MALFUNCTION IN THE PRODUCT DOES NOT EXIST OR WAS  
CAUSED BY CUSTOMER'S OR ANY THIRD PERSON'S MISUSE, NEGLECT, IMPROPER INSTALLATION OR  
TESTING, UNAUTHORIZED ATTEMPTS TO OPEN, REPAIR OR MODIFY THE PRODUCT, OR ANY OTHER  
CAUSE BEYOND THE RANGE OF THE INTENDED USE, OR BY ACCIDENT, FIRE, LIGHTNING, POWER CUTS  
OR OUTAGES, OTHER HAZARDS, OR ACTS OF GOD.  
LIMITATION OF LIABILITY: TO THE FULL EXTENT ALLOWED BY LAW, N-TRON ALSO EXCLUDES FOR  
ITSELF AND ITS SUPPLIERS ANY LIABILITY, WHETHER BASED IN CONTRACT OR TORT (INCLUDING  
NEGLIGENCE), FOR INCIDENTAL, CONSEQUENTIAL, INDIRECT, SPECIAL, OR PUNITIVE DAMAGES OF ANY  
KIND, OR FOR LOSS OF REVENUE OR PROFITS, LOSS OF BUSINESS, LOSS OF INFORMATION OR DATA, OR  
OTHER FINANCIAL LOSS ARISING OUT OF OR IN CONNECTION WITH THE SALE, INSTALLATION,  
MAINTENANCE, USE, PERFORMANCE, FAILURE, OR INTERRUPTION OF ITS PRODUCTS, EVEN IF N-TRON  
OR ITS AUTHORIZED RESELLER HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES, AND  
LIMITS ITS LIABILITY TO REPAIR, REPLACEMENT, OR REFUND OF THE PURCHASE PRICE PAID, AT N-  
TRON'S OPTION. THIS DISCLAIMER OF LIABILITY FOR DAMAGES WILL NOT BE AFFECTED IF ANY  
REMEDY PROVIDED HEREIN SHALL FAIL OF ITS ESSENTIAL PURPOSE.  
DISCLAIMER: Some countries, states, or provinces do not allow the exclusion or limitation of implied warranties or the  
limitation of incidental or consequential damages for certain products supplied to consumers, or the limitation of liability for  
personal injury, so the above limitations and exclusions may be limited in their application to you. When the implied  
warranties are not allowed to be excluded in their entirety, they will be limited to the duration of the applicable written  
warranty. This warranty gives you specific legal rights which may vary depending on local law.  
GOVERNING LAW: This Limited Warranty shall be governed by the laws of the State of Delaware, U.S.A.  
(Revised 2010-11-15)  
page 30 of 30  
Download from Www.Somanuals.com. All Manuals Search And Download.  

NeumannBerlin Microphone KMS 140 User Manual
Norcent Technologies Digital Camera DCS 1050 User Manual
NordicTrack Home Gym 831298961 User Manual
NordicTrack Treadmill NCTL09990 User Manual
Novatel TV Antenna 42GOXX16A4 XT 1 1 User Manual
Palsonic Digital Photo Frame DPF8128WH User Manual
Panasonic Computer Drive CF VDM732U User Manual
Panasonic DVD Player DVD LS84 User Manual
Panasonic Flat Panel Television EE23 User Manual
Panasonic Switch ABV User Manual