Murphy Switch MTH6 User Manual

MTH-96116N  
Revised 04-05  
Section 20  
(00-02-0778)  
Model MTH6 Tach/Hourmeter Overspeed Switch  
Installation and Operation Instructions  
Please read the following information before installing. A visual inspection of this product for damage during shipping is recommended  
before mounting. It is your responsibility to have a qualified person install this unit.  
GENERAL INFORMATION  
Dimensions  
Side View  
Front View  
3-1/8 in.  
(79 mm)  
15/32 in.  
(12 mm)  
WARNING  
BEFORE BEGINNING INSTALLATION OF THIS MURPHY PRODUCT  
®
FRANK W.  
MFR.  
Mounting  
Bracket  
Disconnect all electrical power to the machine.  
Make sure the machine cannot operate during installation.  
Follow all safety warnings of the machine manufacturer.  
Read and follow all installation instructions.  
3-5/8 in.  
(92 mm)  
Diameter  
SETPOINT  
3-33/64 in.  
(89 mm)  
MTH6  
ENTER  
Diameter  
Description  
Mounting Hole  
Back View  
Microprocessor-based digital tachometer and hourmeter with a built-in  
overspeed switch. This Murphy instrument is highly accurate and depend-  
able. It measures speed and running hours and can give an alarm or shut  
down the engine on overspeed.  
3-3/8 in.  
3-9/16 in.  
(90 mm)  
(86 mm) Dia.  
RPM data for the tachometer and overspeed switch is supplied by a mag-  
netic pickup or a battery charging alternator equipped with a “Tach” termi-  
nal (auxiliary AC terminal). The magnetic pickup is installed into the fly-  
wheel housing of an internal combustion engine, so that the starter ring gear  
acts upon it to generate a voltage pulse each time a gear tooth passes the end  
of the magnetic pickup.  
®
FRANK W.  
MFR.  
5
Specifications  
Power Requirements: 8-40 VDC (12, 24 or 32 VDC system).  
Maximum Current:  
MTH6 Mounting Schematic  
12 VDC: 0.011 A, backlight Off; 0.025 A, backlight On.  
24 VDC: 0.008 A, backlight Off; 0. 015 A, backlight On.  
32 VDC: 0.007 A, backlight Off; 0. 010 A, backlight On.  
To mount the MTH6 to your panel, a 3-3/8 in. (86 mm) diameter mount-  
ing hole is required. Remove the mounting bracket and lock nuts (provid-  
ed with the unit).  
Operating Temperature: -4° to 158°F (-20° to 70°C).  
Storage Temperature: -40° to 185°F (-40° to 85°C).  
Case: 1018 Polycarbonate/Polyester blend.  
Speed Input: 4.5 Vrms minimum.  
Input Frequency Range: 25 Hz to 20 kHz.  
Overspeed Switch Rating: 2 A, 50 VDC.  
Overspeed Range: 0 to 9000 kHz.  
Insert the MTH6 module from the front of the panel, see schematic below.  
Replace mounting bracket and secure in place with the lock nuts.  
Mounting  
Bracket  
Mounting Hole  
MTH6 Module  
Pulses per Revolution: 4 to 255.  
Tachometer Range: 0 to 65,535 RPM.  
F
R
A
N
K
W
.
®
M
F
R
.
Tachometer Accuracy: 1% of display reading,  
or -2 RPM whichever is greater.  
Hourmeter Range: 0 to 99999 hrs.  
SETPOINT  
MTH6  
Nuts to  
E
N
T
E
R
Secure  
Mounting  
(provided)  
Hourmeter Resolution: 0.1 hour to 9999.9; 1 hour 10,000 and up.  
Reset Hourmeter: Ground terminal #5 to reset hours to zero.  
Shipping Weight: 14 oz. (435 g).  
Panel  
Shipping Dimensions: 5-1/2 x 5-1/2 x 5-1/2 in. (140 x 140 x 140 mm).  
MTH-96116N page 1 of 2  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Milwaukee Power Hammer 5317 59 User Manual
Moxa Technologies Network Card CP 168U User Manual
Mr Coffee Coffeemaker TF4 User Manual
New Buck Corporation Fan Heater Model 80 User Manual
Oki Printer Accessories 42625501 User Manual
Oreck Vacuum Cleaner U4120H2 User Manual
Oster Electric Steamer 4711 User Manual
Panasonic Answering Machine KX TM80 B User Manual
Panasonic Personal Computer CF T7 User Manual
Panasonic Stereo Receiver AJ SD930B User Manual