OPERATION AND PARTS MANUAL
Multiquip
Submersible Pump
Model ST-3050D
Revision #1 (11/18/02)
MULTIQUIP INC.
PARTS DEPARTMENT:
18910 WILMINGTON AVENUE 800/427-1244
CARSON, CALIFORNIA 90746 FAX:800/672-7877
310-537-3700
800/421-1244NATIONWIDE
FAX: 310 - 537-3927
SERVICE DEPARTMENT:
800/478-1244
FAX: 310 - 537- 4259
Download from Www.Somanuals.com. All Manuals Search And Download.
ST-3050D SUBMERSIBLE PUMP —TABLE OF CONTENTS
Here's How To Get Help ............................................2
Table Of Contents .....................................................3
Parts Ordering Procedures .......................................4
Safety Message Alert Symbols .................................5
Rules For safe Operation ..................................... 6-7
Specifications (Pump) ...............................................7
General Information ..................................................9
ST-3050D Submersible
Pump
Components............................................................10
Application (Float Switches)....................................11
Control Boxes..........................................................12
Control Box Installation (CB200).............................13
230/460 VAC Voltage Selection ...............................14
Pump Wiring Diagram .............................................15
Transformer Wiring Diagram (CB200) ....................16
Control Box Wiring Diagram (CB200) .....................17
Three-Phase Power Installation (CB200) ......... 18-19
Control Box Pre-Setup (CB200)........................ 20-21
Control Box Installation (MP102/104) .....................22
Control Box Wiring Diagram (MP102/104)..............23
Operation .......................................................... 24-25
Maintenance ...........................................................26
Pump Troubleshooting/Performance Curve ............27
Explanation Of Codes In Remarks Column ............28
Suggested Spare Parts ...........................................29
Electric Submersible Pump Assembly .............. 30-33
Electric Motor Assembly.................................... 34-35
Terms and Condition of Sale
—
Parts .....................36
ST-3050D — PARTS & OPERATION MANUAL — REV. 0 (11/18/02) — PAGE 3
Download from Www.Somanuals.com. All Manuals Search And Download.
PARTS ORDERING PROCEDURES
■ Dealer account number
■ Dealer name and address
■ Shipping address (if different than billing address)
■ Return fax number
■ Applicable model number
■ Quantity, part number and description of each part
■ Specify preferred method of shipment:
UPS Ground
•
UPS Second Day or Third Day*
•
UPS Next Day*
•
Federal Express Priority One (please provide us with your Federal
Express account number)*
•
Airborne Express*
•
Truck or parcel post
•
*Normally shipped the same day the order is received, if prior to 2PM west coast time.
Earn Extra Discounts when
you order by FAX!
All parts orders which include complete part numbers
and are received by fax qualify for the following extra
discounts:
Number of
line items ordered
Additional Discount
1-9 items
3%
10+ items**
5%
Get special freight allowances
when you order 10 or more
line items via FAX!**
■
UPS Ground Service at no charge for freight
Now! Direct TOLL-FREE access
to our Parts Department!
■
UPS Third Day Service at one-half of actual freight
cost
Toll-free nationwide:
800-421-1244
No other allowances on freight shipped by any other carrier.
**Common nuts, bolts and washers (all items under $1.00 list price)
do not count towards the 10+ line items.
Toll-free FAX:
*DISCOUNTS ARE SUBJECT TO CHANGE*
800/6-PARTS-7 • 800-672-7877
Fax order discount and UPS special programs revised June 1, 1995
PAGE 4 — ST-3050D — PARTS & OPERATION MANUAL — REV. #1 (11/18/02)
Download from Www.Somanuals.com. All Manuals Search And Download.
ST-3050D SUBMERSIBLE PUMP— SAFETY MESSAGE ALERT SYMBOLS
FORYOUR SAFETY ANDTHE SAFETY OF OTHERS!
HAZARD SYMBOLS
Rotating Parts
Safety precautions should be followed at all times when operating
this equipment. Failure to read and understand the Safety
Messages and Operating Instructions could result in injury to
yourself and others.
NEVER operate equipment with covers,
This Owner's Manual has been
developed to provide complete
instructions for the safe and efficient
or guards removed. Keep fingers, hands,
hair and clothing away from all moving
parts to prevent injury.
operation of the Multiquip Model
ST-3050D Submersible Pump.
Before using this pump, ensure
that the operating individual has
read and understands all
instructions in this manual.
Accidental Starting
ALWAYS place the power source circuit
breaker or ON/OFF switch in the OFF
position, when the pump is not in use.
SAFETY MESSAGE ALERT SYMBOLS
The three (3) Safety Messages shown below will inform you
about potential hazards that could injure you or others. The
Safety Messages specifically address the level of exposure to
the operator, and are preceded by one of three words: DANGER,
WARNING, or CAUTION.
Sight and Hearing hazard
ALWAYS wear approved eye and
hearing protection, if required.
DANGER: You WILL be KILLED or
SERIOUSLY injured if you do not follow
directions.
Respiratory Hazard
WARNING: You CAN be KILLED or
SERIOUSLY injured if you do not follow
directions.
ALWAYS wear approved respiratory
protection, if required.
Equipment Damage Messages
CAUTION: You CAN be injured if you
do not follow directions.
Other important messages are provided throughout this manual
to help prevent damage to your submersible pump, other property,
or the surrounding environment.
Potential hazards associated with the ST-3050D submersible
pump operation will be referenced with Hazard Symbols which
appear throughout this manual, and will be referenced in
conjunction with Safety Message Alert Symbols.
This submersible pump, other
property, or the surrounding
environment could be damaged if
you do not follow instructions.
ST-3050D — PARTS & OPERATION MANUAL — REV. 0 (11/18/02) — PAGE 5
Download from Www.Somanuals.com. All Manuals Search And Download.
ST-3050D SUBMERSIBLE PUMP —RULES FOR SAFE OPERATION
■
■
■
ALWAYS make sure submersible pump is grounded.
CAUTION:
NEVER use gas piping as an electrical ground.
Failure to follow instructions in this manual may
lead to serious injury or even death! This
equipment is to be operated by trained and
qualified personnel only! This equipment is for
industrial use only.
DO NOT place hands or fingers inside pump when pump is
running.
■
■
ALWAYS make certain that the voltage supplied to the pump
is correct. Always read the pump's nameplate to determine
what the power requirements are (230 or 460VAC 3 phase).
The following safety guidelines should always be used when
operating the ST-3050D Submersible Pump:
DO NOT restrict the flow of the discharge hose as it may
cause overheating.
GENERAL SAFETY
■
DO NOT operate or service this equipmen
before reading this entire manual.
■
■
Be careful of discharge whipping under pressure.
Make sure pump installation is accordance with national
and local electrical codes.
■
■
ALWAYS have a qualified electrician perform the pump
wiring installation.
■
■
This equipment should not be operated by persons under 18
years of age.
ALWAYS mount the control box in a vertical position
protected from the elements.
NEVER operate this equipment without proper
protective clothing, shatterproof glasses, steel-toed
boots and other protective devices required by the
job.
■
■
■
NEVER handle pump's AC power cord with wet hands.
NEVER let an extension cord or plug connection lay in water.
NEVER stand in water while AC power cord is connected
to a power source.
■
■
■
■
■
NEVER use a pump with a defective, frayed power cord.
Check the power cord on the pump for cuts in the insulation.
■
■
NEVER operate this equipment when not feeling
NEVER use a extension cord that is frayed or damaged
where the insulation has been cut.
well due to fatigue, illness or taking medicine.
ALWAYS make certain that proper extension cord has been
selected for the job See Table 3.
NEVER operate this equipment under the
influence or drugs or alcohol.
NEVER attempt to use the power cord as a lifting or lowering
device for the submersible pump.
When raising or lowering of the submersible pump is
required, always attach an adequate rope or lifting device
to the correct lifting point (handle) on the pump.
■
NEVER use accessories or attachments, which are not
recommended by Multiquip for this equipment. Damage to the
equipment and/or injury to user may result.
■
ALWAYS place the pump in an up-right position on a
platform before using. The platform will prevent the pump
from burrowing itself on soft sand or mud.
■
■
■
■
Manufacture does not assume responsibility for any accident
due to equipment modifications.
■
■
■
■
NEVER operate pump on its side.
Whenever necessary, replace nameplate, operation and safety
decals when they become difficult read.
DO NOT allow the pump to freeze in water.
NEVER leave an open pump chamber unattended.
ALWAYS check the machine for loosened threads or bolts
before starting.
The electrical voltage required to operate the pump can
cause severe injury or even death through physical contact
with live circuits. ALWAYS disconnect the electrical power
from the pump before performing maintenance on the pump.
NEVER operate the submersible pump in an explosive
atmosphere or near combustible materials. An explosion or fire
could result causing severe bodily harm or even death.
PAGE 6 — ST-3050D — PARTS & OPERATION MANUAL — REV. #1 (11/18/02)
Download from Www.Somanuals.com. All Manuals Search And Download.
ST-3050D SUBMERSIBLE PUMP —RULES FOR SAFE OPERATION
■
ALWAYS make sure that electrical circuits are properly
grounded per the National Electrical Code (NEC) and
local codes before operating pump. Severe injury or death by
electrocution can result from operating an ungrounded pump.
. Emergencies
■
ALWAYS know the location of the nearest fire extinguisher.
■
■
NEVER use this pump to remove water from a swimming pool
when people are in the water.
ALWAYS be sure the operator is familiar with proper safety
precautions and operations techniques before using
submersible pump.
■
■
ALWAYS check pump oil level only when pump is cool.
Expansion due to heat may cause hot! oil to spray from the oil
plug when the oil plug is removed.
DO NOT attempt to thaw-out a frozen pump by using a torch
or other source of flame. Application of heat in this manner
may heat the oil in the seal cavity above the critical point,
causing pump damage.
■
ALWAYS know the location of the nearest and first aid kit.
■
■
■
DO NOT pump water greater than 104 degrees Fahrenheit.
Also DO NOT pump liquids containing acid or alkali.
ALWAYS check the dual voltage connection inside the pump
for proper voltage setting.
■
In emergencies always know the location of the
nearest phone or keep a phone on the job site.
Also know the phone numbers of the nearest
ambulance, doctor and fire department. This
information will be invaluable in the case of an
emergency.
ALWAYS check strainer before pumping. Make sure strainer
is not clogged. Remove any large objects, dirt or debris from
the strainer to prevent clogging.
■
■
ALWAYS use a large basket strainer when pumping water
that contain large debris.
ALWAYS flush pump (clean) after use when pumping water
concentrated with heavy debris. It is very important to always
flush the pump before turning it off to prevent clogging.
■
■
ALWAYS store equipment properly when it is not being used.
Equipment should be stored in a clean, dry location out of the
reach of children.
ALWAYS read, understand, and follow procedures in
Operator’s Manual before attempting to operate equipment.
Maintenance Safety
■
NEVER lubricate components or attempt service on a running
machine.
■
ALWAYS allow the machine a proper amount of time to cool
before servicing.
■
■
Keep the machinery in proper running condition.
Fix damage to the machine immediately and always replace
broken parts.
ST-3050D — PARTS & OPERATION MANUAL — REV. 0 (11/18/02) — PAGE 7
Download from Www.Somanuals.com. All Manuals Search And Download.
ST-3050D SUBMERSIBLE PUMP —SPECIFICATIONS
Table 1. Specifications (Pump)
Model
ST-3050D
Type
Submersible Trash Pump
3.00 in. (76 mm.)
Suction & Discharge Size
270 gallons/minute
(1,022 liters/minute)
Maximum Pumping Capacity
Max. Solids Diameter
Max. Lift
2.00 in. (51 mm.)
25 ft. (7.62 meters)
86 ft. (26.00 meters)
5 HP (3.75 Kw)
Max. Head
Power
Voltage Phase
Starting Amps
230/460 3ø
Pump
77 @ 230 VAC
39 @ 460 VAC
14.2 @ 230 VAC
7.1 @ 460 VAC
Running Amps
Control Box Required
Thermal Overload Protection
Rotation
Yes
Yes
Counter-Clockwise1
180 cc. (.18 Liters)2
Mechanical Oil Seal Capacity
.012 -.025 in.
(.304 - .635 mm.)
Impeller Clearance
RPM (Speed)
3,550 30
Power Cable Length
25 FT. (7.62 Meters)
Dimensions
(Height X Diameter)
10.2 x 26.8 in.
(25.9 X 68 cm.)
Dry Net Weight
120 lbs. (54 Kg.)
1.
2.
Motor Rotation – Upon start-up, the pump "kicks" in the opposite direction of motor rotation.The correct rotation is counter-
clockwise (CCW) as viewed from the impeller end of the pump. Rotation direction for 3-phase pumps is changed by reversing
two of the power leads.
Mechanical Oil Seal – Use a good grade 10 weight non-detergent hydraulic oil (i.e.ShellTurbo 32 or equivalent).Fill oil cavity
75% to 85% full (allow air space for expansion).
PAGE 8 — ST-3050D — PARTS & OPERATION MANUAL — REV. #1 (11/18/02)
Download from Www.Somanuals.com. All Manuals Search And Download.
ST-3050D SUBMERSIBLE PUMP —GENERAL INFORMATION
This pump must always be positioned on a platform in an upright
Introduction
position. NEVER operate the pump by a suspended rope. To
prevent large solids from entering the pump, install a wire mesh
screen or similar barrier around the pump.
The Multiquip Model ST-3050D submersible pump is designed
to pump water and is used for the draining (de-watering) of
swimming pools, well casings construction sites, cofferdams,
manholes, transformer vaults and excavations.
If the pump was used to pump water containing mud, silt, use
clean water to flush out the pump after each use.
A vortex type impeller is attached to the output shaft of a 5.0 HP
electric motor which provides adequate power for general
purpose pumping.This submersible pump is supplied complete
with an electric power cable, and a discharge port located at the
top of the pump which accepts a 3-inch hose.
DO NOT allow the pump to run dry, as this will damage the
pump. During maintenance, dry running is permissible but only
for a few seconds.
NEVER lift the pump by its electrical power cord. ALWAYS lift
the pump by its carrying handle or attached a rope to carrying
handle.
This pump is ideal for portability because of its light weight and
carrying handle. For reliability and long life, a mechanical seal
provides shaft sealing, with an oil chamber separating the pump
section from the motor.
A pump fully submerged pump in liquid will not freeze, unless
the liquid freezes. DO NOT allow a partially submerged pump to
freeze.The expansion of water freezing in the volute may crack
the pump, causing expensive repairs. If there is any danger of
the pump being subjected to freezing temperatures, Lift the pump
from water and allow it to drain thoroughly.
The pump when in use, should be installed as free standing
(upright position) on its strainer base. A 3-inch discharge hose
(not supplied) should be connected to the discharge port located
on top of the pump.The discharge hose should be adequately
supported to avoid stress on the pump.
If the pump jams or the pump rotor locks for any reason,
disconnect the pump from the power source immediately.
Allowing the pump motor to cycle ON and OFF under an overload
condition can burn out the motor.
For maximum water flow, the discharge hose should be kept as
short as possible, and with minimum elevation above the pump.
Remember as the length and/or height of the discharge hose is
increased, the flow of water will be reduced. Also any reduction
in the hose size, and any fittings such as valves or outlet nozzles,
will restrict the water flow.
When replacement of nuts and bolts is required, use only
recommended parts as referenced in the parts section of this
manual.This pump uses metric threads. DO NOT use english
measurement threads.
To avoid back-siphonage when the pump is switched off, ensure
that the end of the discharge hose is installed above the water
level at the final discharge point.
When the pump is switched off, the water remaining in the hose
will run back through the pump.This can be avoided by placing
a non-return valve in the hose nearest the pump.
NEVER use this submersible pump to pump flammable liquids
or operate in a explosive or flammable environment.
Avoid using this pump in conditions where mud, grit, silt or other
debris are present.These conditions could cause blockage and
cause excessive pump wear.
DO NOT install the pump directly into an area where there is a
heavy build-up of mud, grit, silt or debris. If this condition is present,
install the pump on a platform before operating.
ST-3050D — PARTS & OPERATION MANUAL — REV. 0 (11/18/02) — PAGE 9
Download from Www.Somanuals.com. All Manuals Search And Download.
ST-3050D SUBMERSIBLE PUMP —COMPONENTS
Figure 1. Submersible Pump Components
Figures 1 shows the location of the basic components, for the
ST-3050D Submersible Pump.Listed below is a brief explanation
of each component.
6.
Carrying Handle – Always carry the submersible pump
by its handle. NEVER! carry the pump by its power cord.
Carrying or lifting the pump by the power cord, will cause
undue stress on the cord, and ultimately the cord will
become dislodged from the pump.
1.
Strainer Base – This strainer base is made of stainless
steel which is resistant to hardware corrosion. DO NOT
pump large objects or debris with this pump.This pump is
for pumping water only.For de-watering purposes, always
place the strainer base on a platform.
7.
Thermal Overload Protection – This pump will require
the use of an external control box with a thermal overload
protection device that will shut-down the motor in the event
of high operating temperatures.The motor will automatically
restart once the temperature returns to an acceptable
operating temperature.
2.
3.
Volute/Impeller – Impellers are constructed of high-chrome
ductile iron to minimizes wear and prolong service life.
Electric Motor –This unit utilizes a three-phase, 230/460
VAC, 5.0 HP electric motor. Consult with a licenced
electrician before connecting motor to a power source.
Observe all city and local safety codes.
8.
9.
Mechanical Oil Seal – This oil filled seal provides
lubrication when running the pump dry. NEVER! run the
pump dry. Running the pump dry will cause severe damage
to the pump.
4.
5.
Discharge Port – Connect a 3-inch hose to this port.
Remember to adequately support the discharge hose to
avoid stress on the pump.
Mechanical Oil Seal Plug – Remove this plug to check
and add hydraulic oil (Shell 32 or equivalent) to the oil
cavity.This oil protects the mechanical seal.Oil cavity should
be full enough to cover seal spring.
AC Power Cable –This unit is supplied with a 50 ft.(15.24
meters) AC power cable. Always check the cable for signs
of wear.NEVER! use a defective power cable.Replace the
cable immediately if the cable is worn or defective.
PAGE 10 — ST-3050D — PARTS & OPERATION MANUAL — REV. #1 (11/18/02)
Download from Www.Somanuals.com. All Manuals Search And Download.
ST-3050D SUBMERSIBLE PUMP —APPLICATION (FLOAT SWITCHES)
Float Switch Theory
Float Switch (Dual)
There is a tilt-sensitive mercury switch hermetically sealed within
each float. As the liquid level (water) rises or falls, the float changes
its angle until the mercury switch makes (close) or breaks (open)
the circuit.
Float switches (Figure 2) are used for the unattended operation
of the submersible pump.The ST-3050D pump requires the use
of a control box to perform this function. Shown in Figure 2 is an
example of a dual float control switch application.
The length of cord between the float and point of attachment
determines the amount of water to be pumped.
The Model ST-3050D submersible pump requires one each of
the Model SW-1WOP float type mercury switches. These
switches have a pumping range level between 5.5~18 feet
(1.67~5.5 meters). All float switch connections are bare wire (no
plug). The ST-3050D submersible pump must use the CB 200
Control Box when float switches are required for the job
application. The MCP102/104 control boxes do not have float
switch capability.
Contact Multiquip sales department to order float switches.
CONTROL
BOX
EXTERNAL 3-PHASE
(230 OR 460 VOLT)
POWER SOURCE
CAUTION!
HIGH
VOLTAGE!
LIFTING
ROPE
CIRCUIT
BREAKER
CB200
L1
RED
WHITE
BLACK
OFF
MANUAL
AUTO
L2
L3
RESET
ON
AC
AC
POWER
INPUT
FLOAT
SWITCH
INPUTS
POWER
TO
PUMP
GROUND
PUMP
ON
3-INCH
DISCHARGE
HOSE
FLOAT
SWITCHES
PUMP
OFF
SUPPORT
PLATFORM
SUBMERSIBLE
PUMP
Figure 2. Dual Float Control Switch
ST-3050D — PARTS & OPERATION MANUAL — REV. 0 (11/18/02) — PAGE 11
Download from Www.Somanuals.com. All Manuals Search And Download.
ST-3050D SUBMERSIBLE PUMP — CONTROL BOXES
Control Boxes
CONTROL
Control boxes (Figure 3) are available for remote control and
thermal shut-down capability for the submersible pump.These
water resistant control boxes provide electronic overload
protection, watertight housing and glands to prevent water from
leaking into the box, and a float switch interface.
BOX
CAUTION!
HIGH
VOLTAGE!
There are various control box models to choose from, reference
Table 2 for the model that meets your pumping requirements.
CB200
Contact Multiquip sales department to order control boxes as
listed in Table 2.
OFF
MANUAL
AUTO
RESET
ON
AC POWER
INPUT
TO PUMP
ALWAYS have a qualified
licensed electrician perform the
installation of the control box.
FLOAT
SWITCH
INPUT
NOTE
Figure 3. Electrical Control Box (CB-200)
Table 2. Control Box Speifications
Thermal
Overload
Protection Capability
Float
Switch
UL/CSA
Listed
Model No.
VoltageType
230/460 VAC
Three-Phase
CB200
MCP102
MCP104
YES
YES
YES
YES
YES
YES
YES
NO
230 VAC
Three-Phase
460 VAC
Three-Phase
NO
PAGE 12 — ST-3050D — PARTS & OPERATION MANUAL — REV. #1 (11/18/02)
Download from Www.Somanuals.com. All Manuals Search And Download.
ST-3050D SUBMERSIBLE PUMP/CTRL. BOX — INSTALLATION (CB200)
POWER CORD REQUIREMENTS
DANGER:
When routing the three phase power via a power cord to the
controlbox,ALWAYSusethecorrectwiresize.Pleasereference
Table3below(CordLength/WireSize)todeterminethecorrect
wiresize.Incorrectwire sizecanadverselyaffecttheperformance
ofthepump.
To place the ST-3050D submersible pump into operation
requires the use of a control box.The control box contains the
necessaryelectronics(electronicoverloadmodule,floatswitch
connections and 230/460 voltage transformer) to operate the
pump.Rememberthiscontrolboxcontainshazardousvoltages.
Disconnect all sources of power before installing or servicing.
There exists the possibility of electrocution, electric shock or
burn, which can cause severe bodily harm or even death!
TABLE 3. CORD LENGTH AND WIRE SIZES
AMPS
6
50 FT.
100 FT.
16 AWG
14 AWG
14 AWG
14 AWG
12 AWG
12 AWG
150 FT.
14 AWG
12 AWG
12 AWG
12 AWG
10 AWG
10 AWG
16 AWG
16 AWG
16 AWG
14 AWG
14 AWG
12 AWG
8
CAUTION:
10
12
14
16
This control box should only be installed or
serviced by a licensed electrician or qualified
personnel.
CONTROL BOX MOUNTING
Mountthecontrolboxinanuprightverticalposition.Makesure
the control box is securely fastened to a flat surface, that is free
of dust, dirt, moisture or any elements that may contaminate or
erode the electronic components of the control box.
FLOAT SWITCH INSTALLATION (CB200)
1.
Remove the float switch input connector housing, then
route the float switch wires through the cable gland on the
control box. Attach the wires to the float switch terminal
block as indicated byTable 2. Reference Figures 7 and 8.
3-Phase Power Installation (Input)
The ST-3050D submersible pump requires 230/460 3-phase
powerfornormaloperation.Thepumpisshippedfromthefactory
inthe230 VAC configuration.Tochangethevoltagesettingfrom
230 VAC to 460 VAC refer to the transformer wiring section on
page 16.
TABLE 4. FLOAT SWITCH CONNECTIONSS
If you cannot determine what your pump's power
requirements are, look at the vendor supplied identification
name tag attached to the pump or please contact Multiquip's
Service/Technical Assistance department.
FLOAT SWITCH TERMINAL
FLOAT SWITCH
BLOCK NUMBER
START
STOP
TERMINALS 1 AND 2
TERMINALS 3 AND 4
CAUTION:
Applyingincorrect power (voltagephasing)
to the submersible pump can cause severe
damage to the pump. Please make sure that
thecorrect voltageandphaseare transferred
to the pump at all times.
2.
3.
Tighten the connector housing to ensure a tight fit between
the cord and the connector body.This will prevent the cable
from pulling out of the terminal block and also prevent
moisture from entering the control box..
Determine the length of the float switch wires, then secure
float switch wires to pump discharge hose.
ST-3050D — PARTS & OPERATION MANUAL — REV. 0 (11/18/02) — PAGE 13
Download from Www.Somanuals.com. All Manuals Search And Download.
ST-3050D SUBMERSIBLE PUMP — 230/460VACVOLTAGE SELECTION
230/460VACVoltage Selection
3.
Re-install the power cord gland assembly back into the
pump's cavity. Make sure that the gland is seated correctly.
This will prevent any connector pins from bending or
breaking.
The ST-3050D submersible pump is factory set at 230
VAC. To change the voltage from 230 VAC to 460 VAC,
perform the following:
4.
Insert the four retaining screws and tighten securely
1.
Remove the four retaining screws that secure the power
cord gland assembly to the pump casing, and pull the 230
VAC female plug (Figure 4) from the pump's cavity.
2.
Un-plug the 230 VAC female plug from the male motor
windings plug and insert the 460 VAC female plug into
male motor windings plug.
Figure 4. 230/460 VAC Pump Voltage Selection
PAGE 14 — ST-3050D — PARTS & OPERATION MANUAL — REV. #1 (11/18/02)
Download from Www.Somanuals.com. All Manuals Search And Download.
ST-3050D SUBMERSIBLE PUMP — PUMPWIRING DIAGRAM
Figure 5. Pump Wiring Diagram
ST-3050D — PARTS & OPERATION MANUAL — REV. 0 (11/18/02) — PAGE 15
Download from Www.Somanuals.com. All Manuals Search And Download.
ST-3050D SUB. PUMP/CTRL. BOX — TRANSFORMER WIRING (CB200)
TRANSFORMER 230/460VOLTAGE SETTINGS
WARNING:
ALWAYS make sure that the transformer is set
CAUTION:
to the correct output voltage. Incorrect transformer
output voltage settings can cause severe damage
to the pump.
Transformer 230/460 Voltage Settings:
Pump motors are factory set at 230VAC.The
transformer(Figure6)ofthiscontrolboxmust
besettothevoltagerequirementsofthepump
in use. Refer to the attached wiring diagram
located inside the "Control Box" or reference Figures7 & 8.
Usethetwosuppliedjumpertabstosetthetransformertothe
required output voltage.
Figure 6. Transformer AC Voltage Settings (Jumper Tabs)
PAGE 16 — ST-3050D — PARTS & OPERATION MANUAL — REV. #1 (11/18/02)
Download from Www.Somanuals.com. All Manuals Search And Download.
ST-3050D SUB. PUMP/CONTRL. BOX — WIRING DIAGRAM (CB200)
THREE PHASE WIRING
EXTERNAL 3-PHASE
(230 OR 460 VOLT)
POWER SOURCE
ELECTRONIC
OVERLOAD UNIT
TERMINALS
CONNECTIONS
M
O/L
CIRCUIT
BREAKER
1
3
5
2
4
6
L1
L2
L3
T1
L1
RED
WHITE
BLACK
PUMP
MOTOR
T2
T3
L2
L3
H1
H3
H2
H4
CONTROL
TRANSFORMER
50VA CPT
SEE FIGURE 1 FOR JUMPER SELECTION
230 0R 460 VAC SELECTION.
GROUND
F1
6
XF
X1
X2
FUSE
1/2 AMP
ON
INDICATOR
LAMP
OFF
MANUAL
AUTO
5
1
1
7
1
G
11
23
12
24
CONTACTOR
5 HP
4
O/L
1
3
7
6
M
A1
96
A2
95
14 13
TERMINAL
BLOCK
WARNING
ONLYALICENSED ELECTRICIAN
NOTE:
1. REFER TO PAGE 20 OF THIS MANUAL
FOR THE CORRECT SETTING OF THE
ELECTRONIC OVERLOAD UNIT.
OR QUALIFIED PERSONNEL
SHOULD PERFORM WIRING AND
I N S TA L L AT I O N O F T H I S
CONTROLPANEL.
1
4
3
2
STOP
FLOAT
SWITCH
START
FLOAT
SWITCH
Figure 7. Control Box Wiring Diagram
Float switch connections are for
use with the CB200 Control Box
only!
ST-3050D — PARTS & OPERATION MANUAL — REV. 0 (11/18/02) — PAGE 17
Download from Www.Somanuals.com. All Manuals Search And Download.
ST-3050D SUB. PUMP/CTRL. BOX — 3Ø PWR. INSTALLATION (CB200)
3-PHASE POWER CORD (INPUTTO BOX) INSTALLATION
3-PHASE POWER INSTALLATION (OUTPUTTO PUMP)
1.
The three phase input power cord should have four wires. 1.
Each wire is color coded. The colors are RED, WHITE,
BLACK and GREEN.
The three phase output power cord should have four wires.
Each wire is color coded. The colors are RED, WHITE,
BLACK and GREEN.
2.
Remove the 3-phase AC input connector housing from the 2.
control box, then route the three phase input power cable
through the cable gland on the control box. Attach the
wires to the AC terminal block inside the control box as
indicated by Table 5 and Figure 8.
Remove the 3-phase AC output power connector housing
on the control box, then route the three phase output power
cable through the cable gland on the control box. Attach
the wires to the AC terminal blocks on the electronic
overload unit as indicated by Table 6 and Figure 8.
TABLE 5. 3-PHASE AC INPUT POWER CONNECTIONS
S
TABLE 6. 3-PHASE AC OUTPUT POWER CONNECTIONSS
CABLE WIRE COLOR
AC TERMINAL BLOCK #
ELECTRONIC OVERLOAD
CABLE WIRE COLOR
UNIT TERMINAL BLOCK#
RED
L1
L2
RED
2
WHITE
BLACK
GREEN
WHITE
BLACK
GREEN
4
6
L3
GROUND
3.
Tighten the connector housing to ensure a tight fit between
the power cord and the connector body. This will prevent
the cable from pulling out of the terminal block and also
prevent moisture from entering the control box.
GROUND
It is recommended that the power being supplied to the control
box ALWAYS be connected to a circuit breaker or a quick
disconnect switch.Thissafetyfeatureallowsforquickremoval
of power from the control box in the event of an emergency.
Electrical connections to the power
source should only be performed by
a licensed electrician or qualified
personnel.
NOTE
4.
Connect the other end of the 3-phase input power cord to
the voltage source. Remember to provide a means of
disconnecting the power from the control box (circuit breaker
or quick disconnect switch). Also make sure to provide a
good earth ground to the control box.
PAGE 18 — ST-3050D — PARTS & OPERATION MANUAL — REV. #1 (11/18/02)
Download from Www.Somanuals.com. All Manuals Search And Download.
ST-3050D SUB. PUMP/CTRL BOX — 3Ø PWR. INSTALLATION (CB200)
Figure 8.Three Phase
Control Box/Pump System Diagram
ST-3050D — PARTS & OPERATION MANUAL — REV. 0 (11/18/02) — PAGE 19
Download from Www.Somanuals.com. All Manuals Search And Download.
ST-3050D SUBMERSIBLE PUMP/CTRL. BOX — PRE SETUP (CB200)
ELECTRONIC OVERLOAD UNIT SETTINGS
ClassDialSetting
1. Set the CLASS dial pointer (Figure 9) to the HAND position
CAUTION:
10.This controls the reset function only. It does not affect
the ability of the pump to run with or without float switches.
ElectronicOverloadUnit:Alwaysmakesurethat
theelectronicunitsuppliedwiththecontrolboxisset
to the correct amperage.This overload unit must
MATCHtheamperagerequirementsofthepump
motor.
RESETOperation
This electronic control unit has two modes of reset.The modes are
definedasfollows:
Usinganelectronicoverloadunitwithincorrectsettingsmayresultin
serious damage to the pump. Refer to the Pump Amperage
RequirementsTable (Table 7), for the correct overload amperage
settings.
MODE 1
WhentheCLASSdialontheelectronicoverloadmodule isintheHAND
position(manual)theresetbutton(Figure10)onthefrontofthecontrol
boxmustbepushed toresettheunit(restorepower)intheeventof
anoverload.
TherearetwodialsontheElectronicOverloadUnit(Figure9)that
require adjustment to meet the amperage requirement of the pump
motorinuse.
These dials are located on top of the overload unit and are labeled
CLASSandFLC(A).
Use a phillips-head screw driver to adjust the dials to the correct
settings.
Figure 10. Control Box Reset Button
MODE 1
FLC (A) Dial Setting
WhentheCLASSdialontheelectronicoverloadmoduleisintheAUTO
position (automatic mode) the unit will automatically be reset in the
eventofanoverload
1.
Set the FLC (A) dial pointer (Figure 9) to the correct
amperage for the pump motor in use. Use Table 7, to
determine the correct amperage setting.
NOTE
All Multiquip control boxes should
have the CLASS dial set to the HAND
position 10.
Figure 9. Electronic Overload Module
Operation
1.
From the voltage source set the circuit breaker or quick
disconnect switch to the ON position.
TABLE 7. PUMP MOTOR AMPERAGE REQUIREMENTS
S
Control
Box
Volts
(VAC)
Pump Model
Amps
14.2
7.1
Overload Unit
AXE016-6.40-16A
AXE016-6.40-16A
2.
For manual operation of the pump, place the 3-position
operation switch (Figure 11) on the control box in the
MANUAL position.
ST3050D
CB200
CB200
230
460
Three-Phase
ST3050D
Three-Phase
Figure 11. Manual-Off-On SW. (Man Position)
PAGE 20 — ST-3050D — PARTS & OPERATION MANUAL — REV. #1 (11/18/02)
Download from Www.Somanuals.com. All Manuals Search And Download.
ST-3050D SUBMERSIBLE PUMP/CTRL. BOX — PRE SETUP (CB-200)
Shut-Down
1. Place the 3-position operation switch on the control box to
the OFF position (Figure 14).
3.
Verify that the ON indicator (Figure 12) on the control box
is LIT.This means that power is being supplied to the control
box.
Figure 12. Control Box Power ON Indicator
4.
5.
In the manual mode the pump will run continuously. Pay
close attention when running the pump in this mode.
DAMAGE to the pump may occur if pump is not immersed
in water.
Figure 14. Manual-Off-On SW. (OFF Position)
2.
3.
Verify that the control box power ON light is OFF.
Turn the circuit breaker or quick disconnect switch to the
OFF position.
To operate the pump automatically (float switches), place the
3-position operation switch in the AUTO position (Figure 13).
Figure 13. Manual-Off-On SW. (Auto Position)
6.
In the AUTO mode the pump will run as long as there is a
sufficient amount of water.This amount is determined by
the setting of the float switches. The stop float switch
contacts will open when the water level is low and power
will be removed from the pump's motor.
Once the water level has risen back to the appropriate
level the start float switch contacts will close and power
will be restored to the pump's motor.
ST-3050D — PARTS & OPERATION MANUAL — REV. 0 (11/18/02) — PAGE 21
Download from Www.Somanuals.com. All Manuals Search And Download.
ST-3050D SUB. PUMP/CTRL. BOX — INSTALLATION (MCP102/104)
It is recommended that the power being supplied to the control
DANGER:
box ALWAYS be connected to a circuit breaker or a quick
disconnectswitch.This safety feature allowsfor quick removal
of power from the control box in the event of an emergency.
4.
Connect the other end of the 3-phase input power cord to
the voltage source. Remember to provide a means of
disconnecting the power from the control box (circuit breaker
or quick disconnect switch). Also make sure to provide a
good earth ground to the control box.
Remember this control box contains hazardous voltages.
Disconnect all sources of power before installing or servicing.
There exists the possibility of electrocution, electric shock or
burn, which can cause severe bodily harm or even death!
ELECTRONIC OVERLOAD SETTING (230VAC, 3Ø)
1.
Using a small flat-blade screwdriver, set the
amperage dial pointer on the electronic
overload unit to 14.2 amps.
Remember the MCP102 Control Box is to be used only for
230 VAC 3-phase applications and the MCP 104 Control Box
is for 460 VAC 3-phase applications. Neither control box has
float switch capability.
14.2
POWER CORD REQUIREMENTS
When routing the three phase power via a power cord to the
controlbox,ALWAYSusethecorrectwiresize.Pleasereference
Table 3 (Cord Length/Wire Size) to determine the correct wire
size.Incorrectwire sizecanadverselyaffecttheperformanceof
thepump.
ELECTRONIC OVERLOAD SETTING (460VAC, 3Ø)
1.
Using a small flat-blade screwdriver,set the
amperage dial pointer on the electronic
overload unit to 7.1 amps.
7.1
CONTROL BOX MOUNTING
Mountthecontrolboxinanuprightverticalposition.Makesure
the control box is securely fastened to a flat surface, that is free
of dust, dirt, moisture or any elements that may contaminate or
erode the electronic components of the control box.
3-PHASE POWER INSTALLATION (OUTPUTTO PUMP)
1.
The three phase output power cord should have four wires.
Each wire is color coded. The colors are RED, WHITE,
BLACK and GREEN.
3-PHASE POWER CORD (INPUTTO BOX) INSTALLATION
1.
The three phase input power cord should have four wires.
Each wire is color coded. The colors are RED, WHITE,
BLACK and GREEN.
2.
Remove the 3-phase AC output power connector housing
on the control box, then route the three phase output power
cable through the cable gland on the control box. Attach
the wires to the AC terminal blocks on the electronic
overload unit as indicated by Table 6 and Figure 15.
2.
Remove the 3-phase AC input connector housing from the
control box, then route the three phase input power cable
through the cable gland on the control box. Attach the
wires to the terminal block on the electronic overload unit
inside the control box as indicated by Table5andFigure15.
3.
Tighten the connector housing to ensure a tight fit between
the power cord and the connector body. This will prevent
the cable from pulling out of the terminal block and also
prevent moisture from entering the control box.
PAGE 22 — ST-3050D — PARTS & OPERATION MANUAL — REV. #1 (11/18/02)
Download from Www.Somanuals.com. All Manuals Search And Download.
ST-3050D SUB. PUMP/CTRL. BOX —WIRING DIAGRAM (MCP102/104)
CONTROL
BOX
CONTROL
BOX
MOUNT CONTROL
BOX IN AN UPRIGHT
VERTICAL POSITION
AS SHOWN.
MCP104
MCP102
CAUTION
CAUTION
HIGH
VOLTAGE
HIGH
VOLTAGE
(460 VAC, 3Ø)
(230 VAC, 3Ø)
AC POWER
INPUT
AC POWER
INPUT
TO PUMP
TO PUMP
EXTERNAL 3-PHASE
(230/460 VAC)
POWER SOURCE
MCP102/MCP104
ELECTRONIC
CIRCUIT
BREAKER
OVERLOAD
UNIT
L1
RED
WHITE
BLACK
1/L1
3/L2
5/L3
L2
L3
TERMINAL
BLOCK
6 . 3
4
STOP
TEST
START
GROUND
TERMINAL
BLOCK
SET TO
14.2 AMPS
2/T1
4/T2
6/T3
WHITE
RED
BLACK
WHITE
3 PHASE
AC INPUT
POWER CABLE
RED
BLACK
GREEN
GREEN
GROUND
3 PHASE
AC POWER
INPUT
3 PHASE
AC POWER
OUTPUT
3 PHASE
AC OUTPUT
POWER CABLE
WARNING
INSTALLATION IS TO BE PREFORMED
ONLY BY A LICENSED ELECTRICIAN
OR QUALIFIED PERSONNEL.
ST-3050D
SUBMERSIBLE
PUMP
Figure 15. MCP102/104 Control Box Configurations
ST-3050D — PARTS & OPERATION MANUAL — REV. 0 (11/18/02) — PAGE 23
Download from Www.Somanuals.com. All Manuals Search And Download.
ST-3050D SUBMERSIBLE PUMP —OPERATION
Operation
2. Makesurethepumpisalwaysplacedinanuprightposition,
not tilted (Figure 17). Never position the pump directly on a
soft,loosebottom.Remembertoattainmaximumpumping
capacityandpreventexcessivewear, positionthepumpso
it will not burrow itself into sand or clay.
1. Attach a suitable lifting cable (rope) to the carrying handle
(Figure16)onthepumpandlowerthepumpintoplace.For
applicationswherethereisanexcessiveamountofmud,grit
or silt, the use of a support platform is desirable. When
pumpingwaterfromswimmingpooltypeapplicationswhere
thereislittleornodebris,thesupportplatformisnotrequired.
POWER
CORD
LIFTING
ROPE
3-INCH
DISCHARGE
HOSE
CARRYING
HANDLE
SUPPORT
SUBMERSIBLE
PLATFORM
PUMP
Figure 17. Submersible Pump Upright Position
(Incorrect)
3. After the pump has been positioned correctly into place,
power can be applied to the pump's electric motor.
Figure 16. Submersible Pump Upright Position
(Correct)
PAGE 24 — ST-3050D — PARTS & OPERATION MANUAL — REV. #1 (11/18/02)
Download from Www.Somanuals.com. All Manuals Search And Download.
ST-3050D SUBMERSIBLE PUMP —OPERATION
4. NEVER!grabortouchalivepowercord (Figure18)withwet
Pump Shut-Down/Clean-up
hands,thepossibilityexistsofelectricalshock,electrocu-
tion and even death.
1. Remove the power from the pump by turning off the circuit
breakerorswitchthatprovidespowertothepump.Remem-
bertomakesurethathandsaredry(notwet),andfeetarenot
standinginwaterwhenremovingdisconnectingpowerfrom
thepump.
WET
HANDS
2. Usingtheliftingrope,liftthepumpupfromitscurrentposition.
Removethedischargehosefromthedischargeportonthe
pump.
3. Removeallpowercablesandfloatswitchesfromthecontrol
box. Placecablesandfloatswitchesinasuitablecontainer
where they will not get damaged.
POWER
CORD
(POWER ON)
4. Ifthepumpwasusedtopumpmud,gritorsilt,flush vigorously
with clean water.
5. Removethepumpfromthewater.Wipeoffanymudordebris
that might have attached itself to the pump.
Figure 18. Power Cord (Wet Hands)
6. Store pump in a clean dry place away from dirt and debris.
DANGER:
NEVER! grab or touch a live power cord. DO
NOT stand in water when connecting the
pump's power cord into a voltage source.The
possibility exist of electrical shock, electrocution
and possibly death!
3. If all of the pump's electrical requirements have been met,
insert the power plug on the pump into the power source
receptacle.
4. Waitafewsecondsandwatershouldbegintoflowfromthe
dischargehose.
5. Ifwaterisnotflowingfromthedischargehoseornotflowing
freelyafterafewminutes,removethepowerfromthepump
and check the system for leaks.
ST-3050D — PARTS & OPERATION MANUAL — REV. 0 (11/18/02) — PAGE 25
Download from Www.Somanuals.com. All Manuals Search And Download.
ST-3050D SUBMERSIBLE PUMP —MAINTENANCE
LUBRICATION
5. If oil level is low fill with SAE 10 weight non-detergent
hydraulicoil(i.e.ShellTurbo32 orequivalent). Filloilcavity
75% to 85% full (allow air space for expansion). Pump oil
cavity capacity is approximately 180 cc.
To check the oil level of the mechanical seal perform the
following:
1. Lay the pump (Figure 19) on its side with the oil plug facing
upwards.
IMPELLER
1. Make sure the clearance between the impeller and the
friction disk is approximately .012 - .020 inches (.304 - .508
mm.)
2. Remove oil fill plug.
3. Visually inspect oil plug hole to verify that oil cavity is full
enoughtocoversealspring.Checkevery300hours,change
hydraulic oil every 6 months (1,000 hours) or as needed.
2. Ifimpellerisdefectiveorbadlyworn,replaceimpellerimme-
diately.
4. While checking the hydraulic oil level, also check the
condition of the hydraulic oil in the seal cavity . Block the
opening with a finger and roll pump to one side to drain
oil into a small transparent container.If oil is cloudy or has
water in it, drain oil from pump cavity and replace hydrau-
lic oil. Check the seal for wear damage.
Figure 19. Checking Hydraulic Oil
PAGE 26 — ST-3050D — PARTS & OPERATION MANUAL — REV. #1 (11/18/02)
Download from Www.Somanuals.com. All Manuals Search And Download.
ST-3050D SUBMERSIBLE PUMP —TROUBLESHOOTING
TABLE X. PUMP TROUBLESHOOTING
SYMPTOM
POSSIBLE PROBLEM
SOLUTION
Check that proper voltage (230/460 3Ø) is being supplied to the
pump. Also check that there is an adequate amount of current
(amps) to run the pump. Check power source circuit breaker.
Incorrect voltage/amps?
If using float switches check wiring, inspect power cord.
Replace fuse, check cause of blown fuse.
Check electrical connections?
Blown power fuse?
Pump Fails To Start
Disconnect power cord and check for clogging and improper impeller
clearance. Unclog pump. Check overload protection device.
Impeller locked?
Use multimeter to check motor insulation. Insulation resistance must
be approximately 15 megaohms. If resistance is low, disassemble
pump motor and bake windings to dry them.
Wet motor windings?
Defective motor and pump
bearings?
Check for excessive bearing wear, if worn replace bearings. Replace
motor if defective.
Twisted or restricted discharge
hose?
Lay hose flat un-kinked. Remove clog from hose line.
Clean strainer.
Clogged pump strainer?
Pump Fails to Deliver Full
Output
Use a voltmeter to check voltage while pump is energized. Voltage
must be within 10%. Check power source (no load and load). If an
extension cord is used, make sure it has adequate current-carrying
capacity for the required length.
Low voltage?
Impeller worn?
Replace impeller.
Replace water seal.
Tighten securely.
Defective water seal?
Loose Oil Fill Plug?
Water in Seal Oil
Performance Curve
90
TOTAL HEAD
Max 86 ft
CAPACITY
Figure 20.
Performance Chart
Max 264 G.P.M
60
30
Capacity(US.G.P.M)
0
100
200
300
ST-3050D — PARTS & OPERATION MANUAL — REV. 0 (11/18/02) — PAGE 27
Download from Www.Somanuals.com. All Manuals Search And Download.
EXPLANATION OF CODE IN REMARKS COLUMN
How to read the marks and remarks used in this parts
book.
Items Found In the “Remarks” Column
Serial Numbers-Where indicated, this indicates a serial
number range (inclusive) where a particular part is used.
Model Number-Where indicated, this shows that the
corresponding part is utilized only with this specific model
number or model number variant.
Items Found In the “Items Number”Column
All parts with same symbol in the number column, , #,
, belong to the same assembly or kit.
+
, %, or
*
■
PAGE 28 — ST-3050D — PARTS & OPERATION MANUAL — REV. #1 (11/18/02)
Download from Www.Somanuals.com. All Manuals Search And Download.
ST-3050D — SUGGESTED SPARE PARTS
ST-3050D SUBMERSIBLE PUMP 1 TO 3 UNITS
1 to 3 Units
Qty......... P/N.............................. Description
1 ............ 0203050120 ................ AC CORD W/CORD GLAND
1 ............ 0203050060 ................ MECHANICAL SEAL
1 ............ 0203050081 ................ OIL SEAL
1 ............ 0203050047 ................ LINER
1 ............ 0203050003 ................ IMPELLER
1 ............ 0202020004 ................ IMPELLER NUT
2 ............ 0203050214 ................ PACKING
1 ............ 0202020157 ................ PACKING
1 ............ 0202020435 ................ PACKING
1 ............ 0202020435 ................ SPRING WASHER
ST-3050D — PARTS & OPERATION MANUAL — REV. 0 (11/18/02) — PAGE 29
Download from Www.Somanuals.com. All Manuals Search And Download.
ST-3050D — ELECTRIC SUBMERSIBLE PUMP ASSY.
ELECTRIC SUBMERSIBLE PUMP ASSY.
PAGE 30 — ST-3050D — PARTS & OPERATION MANUAL — REV. #1 (11/18/02)
Download from Www.Somanuals.com. All Manuals Search And Download.
ST-3050D — ELECTRIC SUBMERSIBLE PUMP ASSY.
ELECTRIC SUBMERSIBLE PUMP ASSY.
NO
1
2
3
4
5
6
31
32
33
47
53
60
65
81
102
103
104
116
119
119
120
121
127
128
146
147
148
156
157
160
174
188
191
192
PART NO
PART NAME
CASING
QTY.
1
1
1
1
1
1
4
4
4
1
1
1
1
1
1
1
REMARK
0203050001
0203050002
0203050003
0202020004
0202020005
0203050006
0202020031
0202020032
0202020033
0203050047
0202020053
0203050060
0202020065
0203050081
0203050102
0203050103
0203050104
0202020116
0203050119
0203050D119
0203050120
0202020121
0202020127
0202020128
0203050146
0203050147
0203050148
0203050156
0202020157
0203050160
0203050174
0203050188
0202020191
0202020192
FRICTION DISC.
IMPELLER
IMPELLER NUT
SPRING WASHER
IMPELLER KEY
STUD BOLT
NUT
WASHER
LINER
WASHER
MECHANICAL SEAL
PLUG
OIL SEAL
DISCHARGE PORT
PACKING
STUD BOLT
BOLT
MOTOR ........................................ 1 .................... ST-3050
MOTOR ........................................ 1 .................... ST-3050D
AC CORDW/CORD GLAND
CORD CLAMP
CARRYING HANDLE
BOLT
2
3
1
1
1
2
1
4
4
1
1
1
1
4
1
4
1
1
STRAINER
STUD BOLT
SPRING WASHER
HEAD COVER
PACKING
SLEEVE
OUTER PIPE
STRAINER SET PIPE
POWER CORD GLAND CASE
BOLT
PACKING
PACKING
214-1 0203050214
214-2 0203050214
ST-3050D — PARTS & OPERATION MANUAL — REV. 0 (11/18/02) — PAGE 31
Download from Www.Somanuals.com. All Manuals Search And Download.
ST-3050 D— ELECTRIC SUBMERSIBLE PUMP ASSY.
PAGE 32 — ST-3050D — PARTS & OPERATION MANUAL — REV. #1 (11/18/02)
Download from Www.Somanuals.com. All Manuals Search And Download.
ST-3050D — ELECTRIC SUBMERSIBLE PUMP ASSY.
ELECTRIC SUBMERSIBLE PUMP ASSY.
NO
222
224
431
434
435
436
437
438
439
440
441
442
443
444
613
614
615
616
617
618
619
PART NO
PART NAME
NUT
PLUG
NUT
STUFFING BOX
PACKING
SPRING WASHER
CORD GLAND CASE COVER
BOLT
PACKING
CONNECTOR
PACKING
BOLT
WASHER
BOLT
CONNECTOR CASE
BOLT
PACKING
PLUG
GLAND RUBBER
GLAND METAL
BOLT
CONNECTOR
CONNECTOR
QTY.
4
1
2
1
1
2
1
3
1
1
1
3
3
2
1
4
1
1
1
1
3
1
1
REMARK
0203050222
0202020224
0203050431
0203050434
0202020435
0202020436
0202020437
0202020438
0202020439
0202020440
0202020441
0202020442
0202020443
0202020444
0203050D613
0203050D614
0203050D615
0203050D616
0203050D617
0203050D618
0203050D619
ST-3050D
ST-3050D
ST-3050D
ST-3050D
ST-3050D
ST-3050D
ST-3050D
ST-3050D
ST-3050D
620-1 0203050D620A
620-2 0203050D620B
ST-3050D — PARTS & OPERATION MANUAL — REV. 0 (11/18/02) — PAGE 33
Download from Www.Somanuals.com. All Manuals Search And Download.
ST-3050D — ELECTRIC MOTOR ASSY.
ELECTRIC MOTOR ASSY.
PAGE 34 — ST-3050D — PARTS & OPERATION MANUAL — REV. #1 (11/18/02)
Download from Www.Somanuals.com. All Manuals Search And Download.
ST-3050D — ELECTRIC MOTOR ASSY.
ELECTRIC MOTOR ASSY.
NO
131
132
268
269
270
273
322
540
541
606
607
608
PART NO
PART NAME
QTY.
REMARK
0203050131
0202020B132
0203050268
0203050269
0203050270
0203050D273
0202020B322
0203050540
0203050541
0203050606
0203050607
0202020B608
BOLT
4
4
1
1
1
1
4
1
1
1
1
1
WASHER, LOCK
MOTOR A BRACKET
MOTOR B BRACKET
MOTOR ROTOR
MOTOR STATOR
NUT
A PACKING
B PACKING
A BEARING, MOTOR
B BEARING, MOTOR
WASHER, WAVE
ST-3050D — PARTS & OPERATION MANUAL — REV. 0 (11/18/02) — PAGE 35
Download from Www.Somanuals.com. All Manuals Search And Download.
Effective: October 1, 2002
TERMS AND CONDITIONS OF SALE — PARTS
PAYMENT TERMS
5. Partsmustbeinnewandresalablecon- Multiquipreservestherighttoquoteandsell
dition,intheoriginalMultiquippackage(if directtoGovernmentagencies,andtoOriginal
any), and with Multiquip part numbers Equipment Manufacturer accounts who use
Terms of payment for parts are net 10 days.
FREIGHTPOLICY
clearlymarked.
our products as integral parts of their own
products.
All parts orders will be shipped collect or
prepaidwiththechargesaddedtotheinvoice.
All shipments are F.O.B. point of origin.
Multiquip’sresponsibilityceaseswhenasigned
manifesthasbeenobtainedfromthecarrier,
andanyclaimforshortageordamagemustbe
settledbetweentheconsigneeandthecarrier.
6. Thefollowingitemsarenotreturnable:
SPECIALEXPEDITINGSERVICE
a. Obsolete parts. (If an item is in the
price book and shows as being re- A$35.00surchargewillbeaddedtotheinvoice
placedbyanotheritem,itisobsolete.) forspecialhandlingincludingbusshipments,
insuredparcelpostorincaseswhereMultiquip
mustpersonallydeliverthepartstothecarrier.
(such as gaskets, seals, “O” rings,
b. Any parts with a limited shelf life
andotherrubberparts)thatwerepur- LIMITATIONSOFSELLER’SLIABILITY
MINIMUMORDER
chasedmorethansixmonthspriorto
thereturndate.
Multiquip shall not be liable hereunder for
damagesinexcessofthepurchasepriceofthe
The minimum charge for orders from Mul-
tiquipis$15.00net.Customerswillbeasked
for instructions regarding handling of orders
notmeetingthisrequirement.
c. Anylineitemwithanextendeddealer item with respect to which damages are
netpriceoflessthan$5.00.
claimed, and in no event shall Multiquip be
liable for loss of profit or good will or for any
otherspecial,consequentialorincidentaldam-
ages.
d. Special order items.
RETURNEDGOODSPOLICY
e. Electricalcomponents.
f. Paint,chemicals,andlubricants.
g. Decalsandpaperproducts.
h. Itemspurchasedinkits.
Returnshipmentswillbeacceptedandcredit
willbeallowed,subjecttothefollowingprovi-
sions:
LIMITATIONOFWARRANTIES
Nowarranties,expressorimplied,aremade
in connection with the sale of parts or trade
accessoriesnorastoanyenginenotmanufac-
tured by Multiquip. Such warranties made in
connectionwiththesaleofnew,completeunits
are made exclusively by a statement of war-
rantypackagedwithsuchunits,andMultiquip
neitherassumesnorauthorizesanypersonto
assume for it any other obligation or liability
whatever in connection with the sale of its
products.Apartfromsuchwrittenstatementof
warranty, there are no warranties, express,
impliedorstatutory,whichextendbeyondthe
descriptionoftheproductsonthefacehereof.
1. AReturnedMaterialAuthorizationmust
be approved by Multiquip prior to ship-
ment.
7. Thesenderwillbenotifiedofanymaterial
receivedthatisnotacceptable.
2. ToobtainaReturnMaterialAuthorization,
alistmustbeprovidedtoMultiquipParts
Salesthatdefinesitemnumbers,quanti-
ties, and descriptions of the items to be
returned.
8. Suchmaterialwillbeheldforfiveworking
days from notification, pending instruc-
tions.Ifareplyisnotreceivedwithinfive
days,thematerialwillbereturnedtothe
senderathisexpense.
a. Thepartsnumbersanddescriptions
must match the current parts price
list.
9. Creditonreturnedpartswillbeissuedat
dealer net price at time of the original
purchase,lessa15%restockingcharge.
b. The list must be typed or computer
generated.
10. In cases where an item is accepted, for
which the original purchase document
can not be determined, the price will be
basedonthelistpricethatwaseffective
twelvemonthspriortotheRMAdate.
c. The list must state the reason(s) for
thereturn.
d. The list must reference the sales
order(s)orinvoice(s)underwhichthe
itemswereoriginallypurchased.
11. Credit issued will be applied to future
purchasesonly.
e. The list must include the name and
phonenumberofthepersonrequest-
ingtheRMA.
PRICINGANDREBATES
Prices are subject to change without prior
notice.Pricechangesareeffectiveonaspe-
cificdateandallordersreceivedonorafterthat
datewillbebilledattherevisedprice.Rebates
3. AcopyoftheReturnMaterialAuthoriza-
tionmustaccompanythereturnshipment.
4. Freight is at the sender’s expense. All forpricedeclinesandaddedchargesforprice
partsmustbereturnedfreightprepaidto increaseswillnotbemadeforstockonhand
Multiquip’sdesignatedreceivingpoint.
atthetimeofanypricechange.
PAGE 36 — ST-3050D — PARTS & OPERATION MANUAL — REV. #1 (11/18/02)
Download from Www.Somanuals.com. All Manuals Search And Download.
NOTE PAGE
ST-3050D — PARTS & OPERATION MANUAL — REV. 0 (11/18/02) — PAGE 37
Download from Www.Somanuals.com. All Manuals Search And Download.
PARTS AND OPERATION MANUAL
HERE'S HOW TO GET HELP
PLEASE HAVE THE MODEL AND SERIAL NUMBER
ON-HANDWHEN CALLING
PARTS DEPARTMENT
800/427-1244 or 310/537-3700
FAX: 800/672-7877 or 310/637-3284
SERVICE DEPARTMENT
800/478-1244 or 310/537-3700
FAX: 310 - 537-4259
WARRANTY DEPARTMENT
800/421-1244, EXT. 279 or 310/537-3700
FAX: 310 - 537-1173
MAIN
800/421-1244 or 310/537-3700
FAX: 310 - 537-3927
MULTIQUIP INC.
PARTS DEPARTMENT:
18910 WILMINGTON AVENUE 800/427-1244
CARSON, CALIFORNIA 90746 FAX:800/672-7877
310-537-3700
800/421-1244NATIONWIDE
FAX: 310 - 537-3927
SERVICE DEPARTMENT:
800/478-1244
FAX: 310 - 537- 4259
Download from Www.Somanuals.com. All Manuals Search And Download.
|