Moxa Technologies Switch EDS 518A Series User Manual

MOXA EtherDevice™ Switch  
EDS-518A Series User’s Manual  
First Edition, April 2006  
MOXA Networking Co., Ltd.  
Tel:  
+886-2-2910-1230  
Fax: +886-2-2910-1231  
MOXA Technical Support  
Worldwide:  
The Americas  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Table of Contents  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1
Chapter  
1
Introduction  
Welcome to MOXA EtherDevice Switch EDS-518A Series, the Gigabit Managed Redundant  
Ethernet Switch designed specially for connecting Ethernet-enabled devices in industrial field  
applications.  
The following topics are covered in this chapter:  
Overview  
Package Checklist  
Features  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
EDS-518A Series User’s Manual  
Introduction  
Overview  
As the world’s network and information technology becomes more mature, the trend is to use  
Ethernet as the major communications interface in many industrial communications and  
automation applications. In fact, a whole new industry has sprung up to provide Ethernet products  
that comply with the requirements of demanding industrial applications. EDS-518A is designed  
for Gigabit-speed, high port density, ultra-reliable operation in rugged industrial environments,  
and is therefore the best choice for each industrial application.  
Package Checklist  
MOXA EtherDevice Switch EDS-518A Series is shipped with the following items. If any of these  
items are missing or damaged, please contact your customer service representative for assistance.  
y
y
y
y
y
y
y
1 MOXA EtherDevice Switch EDS-518A  
Hardware Installation Guide  
CD-ROM with User’s Manual and Windows Utility  
MOXA Product Warranty booklet  
RJ45 to DB9 Console port cable  
Protective caps for unused ports  
Panel mounting kit (optionalmust order separately)  
Features  
Industrial Networking Capability  
y
y
y
Redundant Gigabit Ethernet Ring Capability (recovery time < 300 ms at full load)  
IGMP Snooping and GMRP for filtering multicast traffic from industrial Ethernet Protocols  
Supports IEEE 802.1Q, Tag-based VLAN, GVRP, and Port-based VLAN to ease network  
planning  
y
y
y
y
y
Supports QoSIEEE 802.1p/1Q and TOS/DiffServ to increase determinism  
Supports 802.3ad, LACP for optimum bandwidth utilization  
Supports IEEE 802.1X and SSL to enhance network security  
SNMP V1/V2c/V3 for different levels of network management security  
RMON for efficient network monitoring and proactive capability  
Designed for Industrial Applications  
y
y
y
y
y
y
y
y
y
y
y
y
y
Bandwidth management prevents unpredictable network status  
Support ABC-01 (Automatic Backup Configurator) for system configuration back up  
Long-haul transmission distance of 40 km or 80 km  
Redundant, dual 12-45 VDC power inputs  
IP 30, rugged high-strength metal case  
DIN-Rail or panel mounting ability  
Bandwidth management to prevent unpredictable network status  
Lock port for authorized MAC address access only  
Port mirroring for online debugging  
Automatic warning by exception through email, relay output  
Digital inputs to integrate a sensor and alarm with an IP network  
Automatic recovery of connected device IP addresses  
Line-swap fast recovery  
1-2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
EDS-518A Series User’s Manual  
Introduction  
Useful Utility and Remote Configuration  
y
y
Configurable using a Web browser, Telnet/Serial console, and Windows utility  
Send ping commands to identify network segment integrity  
Recommended Software and Accessories  
y
y
EDS-SNMP OPC Server Pro  
DR-4524, DR-75-24, DR-120-24 DIN-Rail 24 VDC Power Supply Series  
1-3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
2
Chapter  
2
Getting Started  
This chapter explains how to access EDS-518A for the first time. There are three ways to access  
the switch: serial console, Telnet console, and web browser. The serial console connection method,  
which requires using a short serial cable to connect EDS-518A to a PC’s COM port, can be used if  
you do not know EDS-518A’s IP address. The Telnet console and web browser connection  
methods can be used to access EDS-518A over an Ethernet LAN, or over the Internet.  
The following topics are covered:  
RS-232 Console Configuration (115200, None, 8, 1, VT100)  
Configuration using a Telnet Console  
Configuration using a Web Browser  
Disabling Telnet and Browser Access  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
EDS-518A Series User’s Manual  
Getting Started  
RS-232 Console Configuration (115200, None, 8, 1, VT100)  
Connection Caution!  
NOTE  
1. You cannot connect to EDS-518A simultaneously by serial console and Telnet.  
2. You can connect to EDS-518A simultaneously by web browser and serial console, or by web  
browser and Telnet.  
However, we strongly suggest that you do NOT use more than one connection method at the  
same time. Following this advice will allow you to maintain better control over the  
configuration of your EDS-518A.  
We recommend using MOXA PComm Terminal Emulator, which can be downloaded free of  
charge from MOXA’s website.  
NOTE  
Before running PComm Terminal Emulator, use an RJ45 to DB9-F (or RJ45 to DB25-F) cable to  
connect EDS-518A’s RS-232 Console port to your PC’s COM port (generally COM1 or COM2,  
depending on how your system is set up).  
After installing PComm Terminal Emulator, perform the following steps to access the RS-232  
Console utility.  
1. From the Windows desktop, click Start Æ Programs Æ PCommLite2.5 Æ Terminal  
Emulator.  
2. Select Open under Port Manager to open a new connection.  
2-2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
EDS-518A Series User’s Manual  
Getting Started  
3. The Communication Parameter page of the Property window opens. Select the appropriate  
COM port for Console Connection, 115200 for Baud Rate, 8 for Data Bits, None for Parity,  
and 1 for Stop Bits.  
4. Click the Terminal tab, and select VT100 for Terminal Type. Click OK to continue.  
5. Type 1 to select ansi/VT100 terminal type, and then press Enter.  
2-3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
EDS-518A Series User’s Manual  
Getting Started  
6. The Console login screen will appear. Press Enter to open the Account pop-up selector and  
then select either admin or user. Use the keyboard’s down arrow to move the cursor to the  
Password field, enter the Console Password (this is the same as the Web Browser password;  
leave the Password field blank if a console password has not been set), and then press Enter.  
7. EDS-518A’s Main Menu will be displayed. (NOTE: To modify the appearance of the  
PComm Terminal Emulator window, select Font… under the Edit menu, and then choose the  
desired formatting options.)  
8. After entering the Main Menu, use the following keys to move the cursor, and to select  
options.  
Key  
Function  
Move the onscreen cursor  
Display & select options  
Toggle options  
Up/Down/Left/Right arrows, or Tab  
Enter  
Space  
Esc  
Previous Menu  
2-4  
Download from Www.Somanuals.com. All Manuals Search And Download.  
EDS-518A Series User’s Manual  
Getting Started  
Configuration using a Telnet Console  
You may use Telnet to access EDS-518A’s console utility over a network. To be able to access  
EDS’s functions over the network (by Telnet or Web Browser) from a PC host that is connected to  
the same LAN as EDS-518A, you need to make sure that the PC host and EDS-518A are on the  
same logical subnet. To do this, check your PC host’s IP address and subnet mask. By default,  
EDS-518A’s IP address is 192.168.127.253 and EDS-518A’s subnet mask is 255.255.0.0 (for a  
Class B network). If you do not change these values, and your PC host’s subnet mask is  
255.255.0.0, then its IP address must have the form 192.168.xxx.xxx. On the other hand, if your  
PC host’s subnet mask is 255.255.255.0, then its IP address must have the form 192.168.127.xxx.  
To use EDS-518A’s management and monitoring functions from a PC host connected to the same  
LAN as EDS-518A, you must make sure that the PC host and EDS-518A are on the same logical  
subnet.  
NOTE  
NOTE  
NOTE  
Before accessing the console utility via Telnet, first connect one of EDS-518A’s RJ45 Ethernet  
ports to your Ethernet LAN, or directly to your PC’s Ethernet NIC. You can establish a  
connection with either a straight-through or cross-over Ethernet cable.  
EDS-518A’s default IP is 192.168.127.253.  
Perform the following steps to access the console utility via Telnet.  
1. Click Start Æ Run, and then telnet to EDS-518A’s IP address from the Windows Run  
window. (You may also issue the telnet command from the MS-DOS prompt.)  
2. Type 1 to choose ansi/vt100, and then press Enter.  
2-5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
EDS-518A Series User’s Manual  
Getting Started  
3. The Console login screen will appear. Press Enter to open the Account pop-up selector and  
then select either admin or user. Use the keyboard’s down arrow to move the cursor to the  
Password field, enter the Console Password (this is the same as the Web Browser password;  
leave the Password field blank if a console password has not been set), and then press Enter.  
4. When the Main Menu of EDS-518A’s console utility opens, click Terminal Æ  
preferences… from the menu at the top of the window.  
5. When the Terminal Preferences window opens, make sure that the VT100 Arrows option is  
selected.  
The Telnet Console looks and operates in precisely the same manner as the RS-232 Console.  
NOTE  
Configuration using a Web Browser  
MOXA EDS-518A’s web browser interface provides a convenient way to modify the switch’s  
configuration and access the built-in monitoring and network administration functions. You may  
use either Internet Explorer or Netscape to access EDS-518A.  
To use EDS-518A’s management and monitoring functions from a PC host connected to the same  
LAN as EDS-518A, you must make sure that the PC host and EDS-518A are on the same logical  
subnet.  
NOTE  
If EDS-518A is configured for other VLAN settings, you must make sure your PC host is on the  
management VLAN.  
NOTE  
2-6  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
EDS-518A Series User’s Manual  
Getting Started  
Before accessing EDS-518A’s web browser interface, first connect one of its RJ45 Ethernet ports  
to your Ethernet LAN, or directly to your PC’s Ethernet NIC. You can establish a connection  
with either a straight-through or cross-over Ethernet cable.  
NOTE  
MOXA EDS-518A’s default IP is 192.168.127.253.  
NOTE  
Perform the following steps to access EDS-518A’s web browser interface.  
1. Open Internet Explorer and type EDS-518A’s IP address in the Address field. Press Enter to  
establish the connection.  
2. The web login page will open. Select the login account (Admin or User) and enter the  
Password (this is the same as the Console password), and then click Login to continue. Leave  
the Password field blank if a password has not been set.  
By default, EDS-518A’s password is not set (i.e., is blank).  
NOTE  
You may need to wait a few moments for the web page to be downloaded to your computer. Use  
the menu tree on the left side of the window to open the function pages to access each of MOXA  
EtherDevice Switch’s functions.  
2-7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
EDS-518A Series User’s Manual  
Getting Started  
Disabling Telnet and Browser Access  
If you are connecting EDS-518A to a public network, but do not intend to use its management  
functions over the network, we suggest disabling both Telnet Console and Web Configuration  
from the RS-232 Console’s Basic Settings Æ System Identification page, as shown in the  
following figure.  
2-8  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
3
Chapter  
3
Featured Functions  
This chapter explains how to access EDS-518A’s various configuration, monitoring, and  
administration functions. There are three ways to access these functions: RS-232 console, Telnet  
console, and web browser. The serial console connection method, which requires using a short  
serial cable to connect EDS-518A to a PC’s COM port, can be used if you do not know  
EDS-518A’s IP address. The Telnet console and web browser connection methods can be used to  
access EDS-518A over an Ethernet LAN, or over the Internet.  
The Web Console is the most user-friendly way to configure EDS-518A. In this chapter, we use  
the Web Console interface to introduce the functions. There are only a few differences between the  
Web Console, Serial Console, and Telnet Console.  
The following topics are covered in this chapter:  
Configuring Basic Settings  
Using Port Trunking  
Configuring SNMP  
Using Communication Redundancy  
Using Traffic Prioritization  
Using Virtual LAN  
Using Multicast Filtering  
Using Bandwidth Management  
Using Port Access Control  
Using Auto Warning  
Using Line-Swap-Fast-Recovery  
Using Set Device IP  
Using Diagnosis  
Using Monitor  
Using the MAC Address Table  
Using Event Log  
Using HTTPS/SSL  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
EDS-518A Series User’s Manual  
Featured Functions  
Configuring Basic Settings  
The Basic Settings group includes the most commonly used settings required by administrators to  
maintain and control EDS-518A.  
System Identification  
The system identification items are displayed at the top of the web page, and will be included in  
alarm emails. Entering the system identification information makes it easier to identify the  
different switches connected to your network.  
Switch Name  
Setting  
Max. 30  
Description  
Factory Default  
This option is useful for specifying the role or Managed Redundant Switch  
Characters  
application of different EDS-518A units.  
E.g., Factory Switch 1.  
[Serial No. of this switch]  
Switch Location  
Setting  
Description  
Factory Default  
Max. 80  
Characters  
To specify the location of different EDS-518A Switch Location  
units. E.g., production line 1.  
Switch Description  
Setting  
Description  
Factory Default  
Factory Default  
Max. 30  
Characters  
Use this to enter a more detailed description of None  
the EDS-518A unit.  
Maintainer Contact Info  
Setting  
Description  
Max. 30  
Characters  
To provide information about whom to contact None  
in order to resolve problems. Use this to enter  
contact information of the person responsible  
for maintaining this EDS-518A.  
3-2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
EDS-518A Series User’s Manual  
Featured Functions  
Password  
EDS-518A provides two levels of access privileges: admin privilege gives read/write access to all  
EDS-518A configuration parameters, and user privilege provides read access only. You will be  
able to view the configuration, but will not be able to make modifications.  
ATTENTION  
EDS-518A’s default Password is not set (i.e., is blank). If a Password is already set, then you  
will be required to type the Password when logging into the RS-232 Console, Telnet Console, or  
Web Browser interface.  
Account  
Setting  
Description  
Factory Default  
admin  
user  
“admin” privilege allows the user to modify all  
EDS-518A configurations.  
admin  
“user” privilege only allows viewing EDS-518A  
configurations.  
Password  
Setting  
Old Password  
Description  
Factory Default  
None  
Type current password when changing the  
(Max. 16 Characters) password  
New Password  
Type new password when changing the password None  
(Max. 16 Characters)  
Retype Password  
If you type a new password in the Password field, None  
(Max. 16 Characters) you will be required to retype the password in the  
Retype new password field before updating the  
new password.  
3-3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
EDS-518A Series User’s Manual  
Featured Functions  
Accessible IP  
MOXA EDS-518A uses an IP address-based filtering method to control access to EDS-518A  
units.  
Accessible IP Settings allows you to add or remove “Legal” remote host IP addresses to prevent  
unauthorized access. Access to EDS-518A is controlled by IP address. If a host’s IP address is in  
the accessible IP table, then the host will be allowed access to the EDS-518A. You can allow one  
of the following cases by setting this parameter:  
y
Only one host with the specified IP address can access the EDS-518A  
E.g., enter “192.168.1.1/255.255.255.255” to allow access to just the IP address 192.168.1.1.  
y
Any host on a specific subnetwork can access the EDS-518A  
E.g., enter “192.168.1.0/255.255.255.0” to allow access to all IPs on the subnet defined by  
this IP address/subnet mask combination.  
y
Any host can access the EDS-518A  
Disable this function by deselecting the Enable the accessible IP list option.  
The following table shows additional configuration examples:  
Allowable Hosts  
Input format  
Any host  
Disable  
192.168.1.120  
192.168.1.120 / 255.255.255.255  
192.168.1.0 / 255.255.255.0  
192.168.0.0 / 255.255.0.0  
192.168.1.0 / 255.255.255.128  
192.168.1.128 / 255.255.255.128  
192.168.1.1 to 192.168.1.254  
192.168.0.1 to 192.168.255.254  
192.168.1.1 to 192.168.1.126  
192.168.1.129 to 192.168.1.254  
3-4  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
EDS-518A Series User’s Manual  
Featured Functions  
Port  
Port settings are included to give the user control over Port Access, Port Transmission Speed,  
Flow Control, and Port Type (MDI or MDIX). An explanation of each configuration item follows:  
Enable  
Setting  
checked  
Description  
Factory Default  
enabled  
Allows data transmission through the port.  
Immediately shuts off port access.  
unchecked  
ATTENTION  
If a connected device or sub-network is wreaking havoc on the rest of the network, the Disable  
option under Advanced Settings/Port gives the administrator a quick way to shut off access  
through this port immediately.  
Description  
Setting  
Media type  
Name  
Description  
Factory Default  
N/A  
Displays the media type for each module’s port  
Setting  
Description  
Factory Default  
None  
Max. 63 Characters Specify an alias for each port, and assist the  
administrator in remembering important  
information about the port.  
E.g., PLC 1  
3-5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
EDS-518A Series User’s Manual  
Featured Functions  
Speed  
Setting  
Description  
Factory Default  
Auto  
Allows the port to use the IEEE 802.3u protocol  
to negotiate with connected devices. The port and  
connected devices will determine the best speed  
for that connection.  
Auto  
100M-Full  
100M-Half  
10M-Full  
10M-Half  
Choose one of these fixed speed options if the  
opposing Ethernet device has trouble  
auto-negotiating line speed.  
FDX Flow Ctrl  
This setting enables or disables the flow control capability of this port when the “port transmission  
speed” setting is in “auto” mode. The final result will be determined by the “auto” process  
between EDS-518A and connected devices.  
Setting  
Enable  
Description  
Factory Default  
Enables flow control for this port when in  
auto-negotiate mode.  
Disable  
Disable  
Disables flow control for this port when in  
auto-negotiate mode.  
MDI/MDIX  
Setting  
Description  
Factory Default  
Auto  
Allows the port to auto detect the port type of the  
opposing Ethernet device and change the port  
type accordingly.  
Auto  
MDI  
Choose the MDI or MDIX option if the opposing  
Ethernet device has trouble auto-negotiating port  
type.  
MDIX  
Network  
The Network configuration allows users to modify the usual TCP/IP network parameters. An  
explanation of each configuration item follows.  
3-6  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
EDS-518A Series User’s Manual  
Featured Functions  
Auto IP Configuration  
Setting  
Description  
Factory Default  
Disable  
Set up EDS-518A’s IP address manually.  
By DHCP  
EDS-518A’s IP address will be assigned  
automatically by the network’s DHCP server.  
Disable  
By BOOTP  
EDS-518A’s IP address will be assigned  
automatically by the network’s BOOTP server.  
Switch IP Address  
Setting  
Description  
Factory Default  
IP Address of the  
EDS-518A  
Identifies the EDS-518A on a TCP/IP network. 192.168.127.253  
Switch Subnet Mask  
Setting  
Description  
Factory Default  
Subnet mask of the  
EDS-518A  
Identifies the type of network to which the  
EDS-518A is connected (e.g., 255.255.0.0 for a  
Class B network, or 255.255.255.0 for a Class  
C network).  
255.255.255.0  
Default Gateway  
Setting  
Description  
Factory Default  
Default Gateway of the  
EDS-518A  
The IP address of the router that connects the  
LAN to an outside network.  
None  
DNS IP Address  
Setting  
Description  
Factory Default  
1st DNS Server’s  
IP Address  
The IP address of the DNS Server used by your None  
network. After entering the DNS Server’s IP  
address, you can input EDS-518A’s URL (e.g.,  
www.eds.company.com) in your browser’s  
address field, instead of entering the IP address.  
2nd DNS Server’s  
IP Address  
The IP address of the DNS Server used by your None  
network. EDS-518A will try to locate the 2nd  
DNS Server if the 1st DNS Server fails to  
connect.  
3-7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
EDS-518A Series User’s Manual  
Featured Functions  
Time  
EDS-518A has a time calibration function based on information from an NTP server or user  
specified Time and Date information. Functions such as Auto warning “Email” can add real-time  
information to the message.  
EDS-518A does not have a real time clock. The user must update the Current Time and  
Current Date to set the initial time for EDS-518A after each reboot, especially when the network  
does not have an Internet connection for an NTP server or there is no NTP server on the LAN.  
NOTE  
Current Time  
Setting  
Description  
Factory Default  
User adjustable time.  
The time parameter allows configuration of the None (hh:mm:ss)  
local time in local 24-hour format.  
Current Date  
Setting  
Description  
The date parameter allows configuration of the None  
local date in yyyy/mm/dd format. (yyyy/mm/dd)  
Factory Default  
User adjustable date.  
System Up Time  
Indicates EDS-518A’s up time from the last cold start. The unit is seconds.  
Time Zone  
Setting  
User selectable time zone The time zone setting allows conversion from GMT (Greenwich  
GMT (Greenwich Mean Time) to local time. Mean Time)  
Description  
Factory Default  
Changing the time zone will automatically correct the current time. You should configure the  
time zone before setting the time.  
NOTE  
3-8  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
EDS-518A Series User’s Manual  
Featured Functions  
Time Server IP/Name  
Setting  
Description  
Factory Default  
1st Time Server IP/Name  
IP or Domain address (e.g., 192.168.1.1 or  
time.stdtime.gov.tw or time.nist.gov).  
None  
EDS-518A will try to locate the 2nd NTP  
Server if the 1st NTP Server fails to connect.  
2nd Time Server IP/Name  
Time Server Query Period  
Setting  
Description  
Factory Default  
Query Period  
This parameter determines how frequently the 600 seconds  
time is updated from the NTP server.  
System File Update—By Remote TFTP  
MOXA EDS-518A supports saving your configuration file to a remote TFTP server or local host  
to allow other EDS-518A switches to use the same configuration at a later time, or saving the Log  
file for future reference. Loading pre-saved firmware or a configuration file from the TFTP server  
or local host is also supported for easy upgrading or configuration of EDS-518A.  
TFTP Server IP/Name  
Setting  
Description  
Factory Default  
IP Address of TFTP  
Server  
The IP or name of the remote TFTP server. Must be None  
set up before downloading or uploading files.  
Configuration Files Path and Name  
Setting  
Description  
Factory Default  
Max. 40 Characters  
The path and file name of EDS-518A’s  
configuration file in the TFTP server.  
None  
Firmware Files Path and Name  
Setting  
Description  
Factory Default  
Max. 40 Characters  
The path and file name of EDS-518A’s firmware  
file.  
None  
3-9  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
EDS-518A Series User’s Manual  
Featured Functions  
Log Files Path and Name  
Setting  
Description  
The path and file name of EDS-518A’s log file  
Factory Default  
Max. 40 Characters  
None  
After setting up the desired path and file name, click Activate to save the setting, and then click  
Download to download the prepared file from the remote TFTP server, or click Upload to upload  
the desired file to the remote TFTP server.  
System File Update—By Local Import/Export  
Configuration File  
To export the configuration file of this EDS-518A, click Export to save it to the local host.  
Log File  
To export the Log file of this EDS-518A, click Export and save it to the local host.  
Some operating systems will open the configuration file and log file directly in the web page. In  
such cases, right click Export to save as a file.  
NOTE  
Upgrade Firmware  
To import the firmware file of this EDS-518A, click Browse to select the firmware file already  
saved on your computer. The upgrade procedure will proceed automatically after clicking Import.  
Upload Configuration Data  
To import the configuration file of this EDS-518A, click Browse to select the configuration file  
already saved on your computer. The upgrade procedure will proceed automatically after clicking  
Import.  
3-10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
EDS-518A Series User’s Manual  
Featured Functions  
Factory Default  
The Factory Default function is included to give users a quick way of restoring EDS-518A’s  
configuration settings to their factory default values. This function is available in the Console  
utility (serial or Telnet), and Web Browser interface.  
After activating the Factory Default function, you will need to use the default network settings to  
re-establish a web-browser or Telnet connection with your EDS-518A.  
NOTE  
Using Port Trunking  
Link Aggregation allows one or more links to be aggregated together to form a Link Aggregation  
Group. A MAC client can treat Link Aggregation Groups as if they were a single link.  
EDS-518A’s Port Trunking feature allows devices to communicate by aggregating up to 3 trunk  
groups, with a maximum of 8 ports for each group. If one of the 8 ports fails, the other seven ports  
will provide back up and share the traffic automatically.  
Port trunking can be used to combine up to 8 ports between two EDS-518A switches. If all ports  
on both switch units are configured as 100BaseTX and they are operating in full duplex, the  
potential bandwidth of the connection will be 1600 Mbps.  
The Port Trunking Concept  
MOXA has developed a proprietary Port Trunking protocol that provides the following benefits:  
y
y
Gives you more flexibility in setting up your network connections, since the bandwidth of a  
link can be doubled, tripled, or quadrupled.  
Provides redundancyif one link is broken, the remaining trunked ports share the traffic  
within this trunk group.  
y
y
Load sharingMAC Client traffic may be distributed across multiple links.  
To avoid broadcast storms or loops in your network while configuring a trunk, first disable or  
disconnect all ports that you want to add to the trunk or remove from the trunk. After you  
finish configuring the trunk, enable or re-connect the ports.  
3-11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
EDS-518A Series User’s Manual  
Featured Functions  
If all ports on both switch units are configured as 100BaseTX and they are operating in full duplex,  
the potential bandwidth of the connection will be up to 1.6 Gbps on the EDS-518A. This means  
that users can connect one EDS to another EDS by Port Trunking to double, triple, or quadruple  
the bandwidth of the connection.  
When configuring Port Trunking, note that:  
Each EDS-518A can set a maximum of 3 Port Trunking groups (Trk1/Trk2, 2 trunk groups for  
10/100M ports and Trk3 for Gigabit ports)  
When you activate Port Trunking settings, some advanced functions that you setup with the  
original ports will either be set to factory default values, or disabled:  
y
y
y
y
y
y
y
y
y
Communication Redundancy will be set to the factory default  
Traffic Prioritization will be set to the factory default  
Port-based VLAN or 802.1Q VLAN will be set to the factory default  
Multicast Filtering will be set to the factory default  
Rate Limiting will be set to the factory default  
Port Access Control will be set to the factory default  
Email and Relay Warning will be set to the factory default  
Set Device IP will be set to the factory default  
Mirror Port will be set to the factory default  
You can setup these features again on your Trunking Port.  
Configuring Port Trunking  
The Port Trunking Settings page is used to assign ports to a Trunk Group.  
Step 1: Select Trk1, Trk2, or Trk3 from the Trunk Group drop-down box.  
Step 2: Select Static, or LACP from the Trunk Type drop-down box.  
Step 3: Under Member Ports and Available Ports, select the specific ports.  
Step 4: Use the Up / Down buttons to add/remove designated ports to/from a trunk group.  
3-12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
EDS-518A Series User’s Manual  
Trunk Group (Maximum of 3 trunk groups)  
Featured Functions  
Setting  
Description  
Factory Default  
Trk1, Trk2, Trk3  
Display or designate the Trunk Type and Member  
Ports for Trunk Group 1, 2, 3.  
Trk1  
Trunk Type  
Setting  
Description  
Factory Default  
Static  
Static  
Designated MOXA proprietary trunking protocol  
Designated LACP (IEEE 802.3ad, Link  
Aggregation Control Protocol)  
Static  
LACP  
Available Ports/Member Port  
Setting  
Description  
Factory Default  
Member/Available  
Ports  
Use Up/Down buttons to add/remove specific ports N/A  
from available ports to/from trunk group.  
Check box  
Port  
Check to designate which ports to add or remove.  
Port number  
Unchecked  
N/A  
N/A  
N/A  
N/A  
Port description  
Name  
Displays the media type for each module’s port  
Max. 63 Characters  
Indicates the transmission speed (100M-Full,  
100M-Half, 10M-Full, or 10M-Half)  
Speed  
Indicates if the FDX flow control of this port is  
“Enabled” or “Disabled.”  
N/A  
N/A  
N/A  
FDX Flow Control  
Add designated ports into trunk group from  
available ports.  
Up  
Remove designated ports from trunk group to  
available port.  
Down  
Trunk Table  
Setting  
Description  
Trunk Group  
Member Port  
Status  
Displays the Trunk Type and Trunk Group.  
Display which member ports belong to the trunk group.  
Success means port trunking is working properly.  
Fail means port trunking is not working properly.  
Standby means port trunking is working as a standby port. When there  
are more than eight ports trunked as a trunking group, the 9th port will  
be the standby port.  
3-13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
EDS-518A Series User’s Manual  
Featured Functions  
Configuring SNMP  
EDS-518A supports SNMP V1/V2c/V3. SNMP V1, and SNMP V2c use a community string  
match for authentication, which means that SNMP servers access all objects with read-only or  
read/write permissions using the community string public/private (default value). SNMP V3,  
which requires you to select an authentication level of MD5 or SHA, is the most secure protocol.  
You can also enable data encryption to enhance data security.  
SNMP security modes and security levels supported by EDS-518A are shown in the following  
table. Select the security mode and level that will be used to communicate between the SNMP  
agent and manager.  
Protocol  
Version  
Authentication  
Type  
Data  
Encryption  
UI Setting  
Method  
V1, V2c  
Read  
Community  
Community  
string  
Use a community string match  
for authentication  
No  
SNMP V1,  
V2c  
V1, V2c  
Write/Read  
Community  
Community  
string  
Use a community string match  
for authentication  
No  
No  
Use account with admin or user  
to access objects  
No-Auth  
No  
Provides authentication based on  
HMAC-MD5, or HMAC-SHA  
algorithms. 8-character  
passwords are the minimum  
requirement for authentication.  
Authentication  
MD5 or SHA based on MD5 No  
or SHA  
SNMP V3  
Provides authentication based on  
HMAC-MD5 or HMAC-SHA  
algorithms, and data encryption  
key. 8-character passwords and a  
data encryption key are the  
Authentication  
MD5 or SHA based on MD5  
or SHA  
Data encryption  
key  
minimum requirements for  
authentication and encryption.  
These parameters are configured on the SNMP page. A more detailed explanation of each  
parameter follows.  
SNMP Read/Write Settings  
SNMP Versions  
Setting  
Description  
Factory Default  
V1, V2c  
V1, V2c, V3, or  
V1, V2c, or  
V3 only  
Select the SNMP protocol version used to  
manage the switch.  
V1, V2c Read Community  
Setting  
Description  
Factory Default  
Use a community string match with a  
maximum of 30 characters for  
authentication. The SNMP agent accesses public  
all objects with read-only permissions  
using the community string public.  
V1, V2c Read  
Community  
3-14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
EDS-518A Series User’s Manual  
Featured Functions  
V1, V2c Write/Read Community  
Setting  
Description  
Factory Default  
Uses a community string match with a  
maximum of 30 characters for  
V1, V2c  
Read/Write  
Community  
authentication. The SNMP servers access private  
all objects with read/write permissions  
using the community string private.  
For SNMP V3, there are two levels of privileges for different accounts to access the EDS-518A.  
Admin privilege allows access, and authorization to read and write the MIB file. User privilege  
only allows reading the MIB file, but does not have authorization to write.  
Admin Auth. Type (for SNMP V1, V2c, V3, and V3 only)  
Setting  
Description  
Factory Default  
Use admin. account to access objects.  
No authentication  
No-Auth  
No  
No  
Provide authentication based on the  
HMAC-MD5 algorithms. 8-character  
passwords are the minimum requirement  
for authentication.  
MD5-  
Auth  
Provide authentication based on the  
HMAC-SHA algorithms. 8-character  
passwords are the minimum requirement  
for authentication.  
SHA-  
Auth  
No  
Admin Data Encryption Key (for SNMP V1, V2c, V3, and V3 only)  
Setting  
Description  
Factory Default  
Factory Default  
8-character data encryption key is the  
minimum requirement for data encryption No  
(maximum of 30 characters)  
Enable  
Disable  
No data encryption  
No  
User Auth. Type (for SNMP V1, V2c, V3 and V3 only)  
Setting  
No-Auth  
Description  
Use admin account or user account to  
access objects. No authentication.  
No  
No  
Provides authentication based on the  
HMAC-MD5 algorithms. 8-character  
passwords are the minimum requirement  
for authentication.  
MD5-Auth  
SHA-Auth  
Provides authentication based on the  
HMAC-SHA algorithms. 8-character  
passwords are the minimum requirement  
for authentication.  
No  
3-15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
EDS-518A Series User’s Manual  
User Data Encryption Key (for SNMP V1, V2c, V3 and V3 only)  
Featured Functions  
Setting  
Enable  
Disable  
Description  
Factory Default  
8-character data encryption key is the  
minimum requirement for data encryption No  
(maximum of 30 characters)  
No data encryption  
No  
Trap Settings  
1st Trap Server IP/Name  
Setting  
Description  
Enter the IP address or name of the 1st  
Trap Server used by your network.  
Factory Default  
IP or Name  
None  
1st Trap Community  
Setting  
Description  
Factory Default  
public  
Use a community string match for  
authentication (maximum of 30  
characters).  
character string  
2nd Trap Server IP/Name  
Setting  
Description  
Enter the IP address or name of the 2nd  
Trap Server used by your network.  
Factory Default  
None  
IP or Name  
2nd Trap Community  
Setting  
Description  
Factory Default  
public  
Use a community string match for  
authentication (maximum of 30  
characters).  
character string  
Private MIB information  
Switch Object ID  
Setting  
Description  
Factory Default  
Fixed  
8691.7.5  
EDS-518A’s enterprise value  
NOTE: The Switch Object ID cannot be changed.  
Using Communication Redundancy  
Setting up Communication Redundancy on your network helps protect critical links against failure,  
protects against network loops, and keeps network downtime at a minimum.  
The Communication Redundancy function allows the user to set up redundant loops in the  
network to provide a backup data transmission route in the event that a cable is inadvertently  
disconnected or damaged. This is a particularly important feature for industrial applications, since  
it could take several minutes to locate the disconnected or severed cable. For example, if MOXA  
EDS-518A is used as a key communications component of a production line, several minutes of  
downtime could cause a big loss in production and revenue. MOXA EDS-518A supports two  
different protocols for this communication redundancy function—Rapid Spanning Tree Protocol  
(IEEE-802.1w) and Turbo Ring.  
3-16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
EDS-518A Series User’s Manual  
Featured Functions  
Turbo Ring and STP/RSTP cannot both be used on the network at the same time. The following  
table lists the key differences between each feature. Use this information to evaluate the benefits  
of each, and then determine which features are most suitable for your network.  
Turbo Ring  
Ring  
STP  
RSTP  
Topology  
Ring, Mesh  
Up to 30 sec.  
Ring, Mesh  
Up to 5 sec  
Recovery Time  
< 300 ms  
Gigabit Ethernet Redundant Ring Capability (< 300 ms)  
Ethernet has become the default data communications medium for industrial automation  
applications. In fact, Ethernet is often used to integrate video, voice, and high-rate industrial  
application data transfers into one network. MOXA EDS-518A, which comes equipped with a  
redundant Gigabit Ethernet protocol called Gigabit Turbo Ring, gives system maintainers a  
convenient means of setting up a versatile yet stable Gigabit Ethernet network. With Gigabit  
Turbo Ring, if any segment of the network gets disconnected, your automation system will be  
back to normal in less than 300 ms.  
Port trunking and Turbo Ring can be enabled simultaneously to form a backbone. Doing so will  
NOTE  
increase the bandwidth of the backbone, and also provide redundancy. For example, suppose that  
two physical ports, 1 and 2, are trunked to form trunk group Trk1, and then Trk1 is set as one  
Turbo Ring path, if port 1 gets disconnected, the remaining trunked port, port 2, will share the  
traffic. If port 1 and port 2 are both disconnected, Turbo Ring will create the back up path within  
300 ms.  
The Turbo Ring Concept  
The proprietary Turbo Ring protocol was developed by MOXA to optimize communication  
redundancy and achieve a faster recovery time on the network.  
Turbo Ring protocol identifies one switch as the “master” of the network, and then automatically  
blocks packets from traveling through any of the network’s redundant loops. In the event that one  
branch of this ring gets disconnected from the rest of the network, the Turbo Ring protocol  
automatically readjusts the ring (if possible) so that the part of the network that was disconnected  
reestablishes contact with the rest of the network.  
3-17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
EDS-518A Series User’s Manual  
Initial Setup  
Featured Functions  
1. Select any two ports as redundant ports.  
2. Connect the redundant ports to form the  
Turbo Ring  
You do not need to set the Master to use Turbo Ring. Master is only needed to identify which  
segment acts as the backup path. The actual topology of the redundant ring, i.e., which segment  
will be blocked, is determined by the number of EDS-518A switches that make up the ring, and  
where the “Ring Master” is located.  
When the number of EDS-518A units in the Turbo Ring is even.  
Master  
If there are 2N EDS-518A units (an even  
number) in the Turbo Ring, then the backup  
segment is one of the two segments connected to  
the (N+1)st EDS-518A (i.e., the EDS-518A unit  
directly opposite the Master).  
3-18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
EDS-518A Series User’s Manual  
Featured Functions  
When the number of EDS-518A units in the Turbo Ring is odd.  
Master  
If there are 2N+1 EDS-518A units (an odd  
number) in the Turbo Ring, with EDS-518A  
units and segments labeled counterclockwise,  
then segment N+1 will serve as the backup path.  
For the example shown here, N=1, and therefore  
N+1=2.  
Segment N+1  
For some systems, it may not be convenient to connect all devices in the system to make one BIG  
redundant ring, since some devices could be located in a remote area. The “Ring Coupling”  
function of Turbo Ring can help you separate those distributed devices into different smaller  
redundant rings, but in such a way that they can still communicate with each other. The following  
figure illustrates how to couple two Turbo Rings.  
ATTENTION  
In a VLAN environment, you must set “Redundant Port,” “Coupling Port,” and “Coupling  
Control Port” as “Trunk Port,” since these ports act as the “backbone” to transmit all packets of  
different VLANs to different EDS-518A units.  
Ring Coupling  
Switch B  
Switch D  
Main Path  
Coupling  
Control Port  
Backup Path  
Coupling Port  
Switch A: "Coupler"  
Switch C  
To support the Ring Coupling function, select two EDS-518A (e.g., Switch A and B in the above  
figure) in the Turbo Ring and another two EDS-518A in the adjacent Turbo Ring (e.g., Switch C  
and D).  
3-19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
EDS-518A Series User’s Manual  
Featured Functions  
Decide appropriate coupling ports in each switch and link them together. Next, assign one switch  
(e.g., Switch A) as coupler and set the proper coupling control port with another switch (e.g.,  
Switch B) in the same Turbo Ring, and then connect them. The Coupler switch (e.g., Switch A)  
will monitor switch B through the coupling control port to decide if the coupling port’s backup  
path should be recovered or not.  
ATTENTION  
The user only needs to enable the “Ring Coupling” function on one EDS-518A (not on the  
opposing EDS-518A or an adjacent EDS-518A). The Redundant Port, Coupling Port, and  
Coupling Control Port must all be assigned to different ports.  
Ring Coupling and Ring Master do not need to be set up on the same EDS-518A.  
NOTE  
Configuring Turbo Ring  
Use the Communication Redundancy page to configure Turbo Ring.  
Now Active  
This field shows which communication protocol is in use: Turbo Ring, RSTP, or neither.  
Master/Slave  
This field appears only when Turbo Ring mode is selected for Redundancy Protocol. It indicates if  
this EDS-518A is or is not the Master of the Turbo Ring.  
The user does not need to set the master to use Turbo Ring, only to assign which segment serves  
as the backup path.  
NOTE  
The master will be determined automatically if the user does not set a dedicated master for the  
Turbo Ring.  
3-20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
EDS-518A Series User’s Manual  
Featured Functions  
Redundant Port Status  
This field indicates the current status of redundant ports. The state is “Forwarding” for normal  
transmission, “Blocked” for transmission that is stopped if this port is the backup path, and “Link  
down” for non-connection.  
Ring Coupling  
Indicates if the Ring Coupling function is “Enabled” or “Disabled.”  
Coupling Port Status  
This indicates the current status of coupling ports. The state is “Forwarding” for normal  
transmission, “Blocked” for transmission that is stopped if this port is the backup path, and “Link  
down” for non-connection.  
At the bottom of the page, the user can configure this function’s “Settings.” For Turbo Ring, the  
user can configure:  
Redundancy Protocol  
Setting  
Description  
Factory Default  
Select this item to change to the  
Turbo Ring configuration page.  
Turbo Ring  
None  
None  
RSTP (IEEE  
802.1W/1D)  
Select this item to change to the  
RSTP configuration page.  
Set as Master  
Setting  
Description  
Factory Default  
Factory Default  
Enable/Disable  
Select this EDS-518A as Master  
None  
Redundant Ports  
Setting  
Description  
Select any port of EDS-518A to be Port G1 if enabled for  
one of the redundant ports. Turbo Ring  
1st Port  
Select any port of EDS-518A to be Port G2 if enabled for  
2nd Port  
one of the redundant ports.  
Turbo Ring  
Enable Ring Coupling  
Setting  
Description  
Factory Default  
Enable/Disable  
Select this EDS-518A as Coupler  
None  
Coupling Ports  
Setting  
Description  
Factory Default  
Select any port of EDS-518A to be Port 2 if enabled for  
Coupling Port  
Coupling Control Port  
the coupling port  
Ring Coupling  
Select any port of EDS-518A to be Port 1 if enabled for  
the coupling control port Ring Coupling  
The STP/RSTP Concept  
Spanning Tree Protocol (STP) was designed to help reduce link failures in a network, and provide  
protection from loops. Networks that have a complicated architecture are prone to broadcast  
storms caused by unintended loops in the network. MOXA EDS-518A’s STP feature is disabled  
by default. To be completely effective, you must enable RSTP/STP on every EDS-518A  
connected to your network.  
3-21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
EDS-518A Series User’s Manual  
Featured Functions  
Rapid Spanning Tree Protocol (RSTP) implements the Spanning Tree Algorithm and Protocol  
defined by IEEE Std 802.1w-2001. RSTP provides the following benefits:  
y
y
The topology of a bridged network will be determined much more quickly compared to STP.  
RSTP is backward compatible with STP, making it relatively easy to deploy. For example:  
¾
¾
Defaults to sending 802.1D style BPDUs if packets with this format are received.  
STP (802.1D) and RSTP (802.1w) can operate on different ports of the same EDS-518A.  
This feature is particularly helpful when EDS-518A ports connect to older equipment,  
such as legacy switches.  
You get essentially the same functionality with RSTP and STP. To see how the two systems differ,  
see the Differences between RSTP and STP section in this chapter.  
The STP protocol is part of the IEEE Std 802.1D, 1998 Edition bridge specification. The  
following explanation uses bridge instead of switch.  
NOTE  
What is STP?  
STP (802.1D) is a bridge-based system that is used to implement parallel paths for network traffic.  
STP uses a loop-detection process to:  
y
y
Locate and then disable less efficient paths (i.e., paths that have a lower bandwidth).  
Enable one of the less efficient paths if the most efficient path fails.  
The figure below shows a network made up of three LANs separated by three bridges. Each  
segment uses at most two paths to communicate with the other segments. Since this configuration  
can give rise to loops, the network will overload if STP is NOT enabled.  
LAN 1  
Bridge B  
LAN 2  
Bridge A  
Bridge C  
LAN 3  
If STP is enabled, it will detect duplicate paths and prevent, or block, one of them from forwarding  
traffic. In the following example, STP determined that traffic from LAN segment 2 to LAN  
segment 1 should flow through Bridges C and A because this path has a greater bandwidth and is  
therefore more efficient.  
3-22  
Download from Www.Somanuals.com. All Manuals Search And Download.  
EDS-518A Series User’s Manual  
Featured Functions  
LAN 1  
LAN 2  
LAN 3  
Bridge B  
Bridge C  
Bridge A  
What happens if a link failure is detected? As shown in next figure, the STP process reconfigures  
the network so that traffic from LAN segment 2 flows through Bridge B.  
LAN 1  
Bridge B  
LAN 2  
LAN 3  
Bridge A  
Bridge C  
STP will determine which path between each bridged segment is most efficient, and then assigns a  
specific reference point on the network. When the most efficient path has been identified, the other  
paths are blocked. In the previous 3 figures, STP first determined that the path through Bridge C  
was the most efficient, and as a result, blocked the path through Bridge B. After the failure of  
Bridge C, STP re-evaluated the situation and opened the path through Bridge B.  
How STP Works  
When enabled, STP determines the most appropriate path for traffic through a network. The way it  
does this is outlined in the sections below.  
STP Requirements  
Before STP can configure the network, the system must satisfy the following requirements:  
y
Communication between all the bridges. This communication is carried out using Bridge  
Protocol Data Units (BPDUs), which are transmitted in packets with a known multicast  
address.  
y
Each bridge must have a Bridge Identifier that specifies which bridge acts as the central  
reference point, or Root Bridge, for the STP system—bridges with a lower Bridge Identifier  
are more likely to be designated as the Root Bridge. The Bridge Identifier is calculated using  
the MAC address of the bridge and a priority defined for the bridge. The default priority of  
EDS-518A is 32768.  
3-23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
EDS-518A Series User’s Manual  
Featured Functions  
y
Each port has a cost that specifies the efficiency of each link. The efficiency cost is usually  
determined by the bandwidth of the link, with less efficient links assigned a higher cost. The  
following table shows the default port costs for a switch:  
Port Speed  
Path Cost 802.1D,  
1998 Edition  
Path Cost  
802.1w-2001  
10 Mbps  
100  
19  
4
2,000,000  
200,000  
20,000  
100 Mbps  
1000 Mbps  
STP Calculation  
The first step of the STP process is to perform calculations. During this stage, each bridge on the  
network transmits BPDUs. The following items will be calculated:  
y
y
y
Which bridge should be the Root Bridge. The Root Bridge is the central reference point from  
which the network is configured.  
The Root Path Costs for each bridge. This is the cost of the paths from each bridge to the Root  
Bridge.  
The identity of each bridge’s Root Port. The Root Port is the port on the bridge that connects  
to the Root Bridge via the most efficient path. In other words, the port connected to the Root  
Bridge via the path with the lowest Root Path Cost. The Root Bridge, however, does not have  
a Root Port.  
y
The identity of the Designated Bridge for each LAN segment. The Designated Bridge is the  
bridge with the lowest Root Path Cost from that segment. If several bridges have the same  
Root Path Cost, the one with the lowest Bridge Identifier becomes the Designated Bridge.  
Traffic transmitted in the direction of the Root Bridge will flow through the Designated  
Bridge. The port on this bridge that connects to the segment is called the Designated Bridge  
Port.  
STP Configuration  
After all the bridges on the network agree on the identity of the Root Bridge, and all other relevant  
parameters have been established, each bridge is configured to forward traffic only between its  
Root Port and the Designated Bridge Ports for the respective network segments. All other ports are  
blocked, which means that they will not be allowed to receive or forward traffic.  
STP Reconfiguration  
Once the network topology has stabilized, each bridge listens for Hello BPDUs transmitted from  
the Root Bridge at regular intervals. If a bridge does not receive a Hello BPDU after a certain  
interval (the Max Age time), the bridge assumes that the Root Bridge, or a link between itself and  
the Root Bridge, has gone down. This will trigger the bridge to reconfigure the network to account  
for the change. If you have configured an SNMP trap destination, when the topology of your  
network changes, the first bridge to detect the change sends out an SNMP trap.  
Differences between RSTP and STP  
RSTP is similar to STP, but includes additional information in the BPDUs that allow each bridge  
to confirm that it has taken action to prevent loops from forming when it decides to enable a link  
to a neighboring bridge. Adjacent bridges connected via point-to-point links will be able to enable  
a link without waiting to ensure that all other bridges in the network have had time to react to the  
change. The main benefit of RSTP is that the configuration decision is made locally rather than  
network-wide, allowing RSTP to carry out automatic configuration and restore a link faster than  
STP.  
3-24  
Download from Www.Somanuals.com. All Manuals Search And Download.  
EDS-518A Series User’s Manual  
STP Example  
Featured Functions  
The LAN shown in the following figure has three segments, with adjacent segments connected  
using two possible links. The various STP factors, such as Cost, Root Port, Designated Bridge Port,  
and Blocked Port are shown in the figure.  
LAN Segment 1  
Port 1  
Port 1  
Port 1  
(Root Port)  
(Root Port)  
(Designated  
Bridge Port)  
Cost =100  
Cost =100  
Bridge B  
Bridge X  
Port 2  
Bridge A  
Port 2  
Port 2  
(Designated  
Bridge Port)  
(Blocked Port)  
(Root Bridge)  
LAN Segment 2  
Port 1  
(Root Port)  
Cost =100  
Port 1  
(Root Port)  
Cost =200  
Bridge C  
Bridge Y  
Port 2  
Port 2  
(Designated  
Bridge Port)  
(Blocked Port)  
LAN Segment 3  
y
y
y
y
Bridge A has been selected as the Root Bridge, since it was determined to have the lowest  
Bridge Identifier on the network.  
Since Bridge A is the Root Bridge, it is also the Designated Bridge for LAN segment 1. Port 1  
on Bridge A is selected as the Designated Bridge Port for LAN Segment 1.  
Ports 1 of Bridges B, C, X, and Y are all Root Ports sine they are nearest to the Root Bridge,  
and therefore have the most efficient path.  
Bridges B and X offer the same Root Path Cost for LAN segment 2. However, Bridge B was  
selected as the Designated Bridge for that segment since it has a lower Bridge Identifier. Port  
2 on Bridge B is selected as the Designated Bridge Port for LAN Segment 2.  
y
Bridge C is the Designated Bridge for LAN segment 3, because it has the lowest Root Path  
Cost for LAN Segment 3:  
¾
¾
The route through Bridges C and B costs 200 (C to B=100, B to A=100)  
The route through Bridges Y and B costs 300 (Y to B=200, B to A=100)  
y
The Designated Bridge Port for LAN Segment 3 is Port 2 on Bridge C.  
Using STP on a Network with Multiple VLANs  
IEEE Std 802.1D, 1998 Edition, does not take into account VLANs when calculating STP  
information—the calculations only depend on the physical connections. Consequently, some  
network configurations will result in VLANs being subdivided into a number of isolated sections  
by the STP system. You must ensure that every VLAN configuration on your network takes into  
account the expected STP topology and alternative topologies that may result from link failures.  
3-25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
EDS-518A Series User’s Manual  
Featured Functions  
The following figure shows an example of a network that contains VLANs 1 and 2. The VLANs  
are connected using the 802.1Q-tagged link between Switch B and Switch C. By default, this link  
has a port cost of 100 and is automatically blocked because the other Switch-to-Switch  
connections have a port cost of 36 (18+18). This means that both VLANs are now  
subdivided—VLAN 1 on Switch units A and B cannot communicate with VLAN 1 on Switch C,  
and VLAN 2 on Switch units A and C cannot communicate with VLAN 2 on Switch B.  
Switch A  
VLAN1  
VLAN2  
100BaseTX  
100BaseTX  
full-duplex Link;  
only carries VLAN1  
(path cost = 18)  
full-duplex Link;  
only carries VLAN2  
(path cost = 18)  
Switch B  
Switch C  
Block  
VLAN1  
VLAN2  
VLAN1  
VLAN2  
802.1Q tagged,  
10BaseTx  
half-duplex Link  
carries VLAN1, 2  
(path cost = 100)  
To avoid subdividing VLANs, all inter-switch connections should be made members of all  
available 802.1Q VLANs. This will ensure connectivity at all times. For example, the connections  
between Switches A and B, and between Switches A and C should be 802.1Q tagged and carrying  
VLANs 1 and 2 to ensure connectivity.  
See the “Configuring Virtual LANs” section for more information about VLAN Tagging.  
Configuring STP/RSTP  
The following figures indicate which Spanning Tree Protocol parameters can be configured. A  
more detailed explanation of each parameter follows.  
At the top of this page, the user can check the “Current Status” of this function. For RSTP, you  
will see:  
3-26  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
EDS-518A Series User’s Manual  
Featured Functions  
Now Active:  
This will show which communication protocol is being used—Turbo Ring, RSTP, or neither.  
Root/Not Root  
This field will appear only when selected to operate in RSTP mode. It indicates whether or not this  
EDS-518A is the Root of the Spanning Tree (the root is determined automatically).  
At the bottom of this page, the user can configure the “Settings” of this function. For RSTP, you  
can configure:  
Protocol of Redundancy  
Setting  
Turbo Ring  
Description  
Factory Default  
Select this item to change to the Turbo Ring  
configuration page.  
None  
RSTP (IEEE 802.1W/1D) Select this item to change to the RSTP  
configuration page.  
None  
Bridge priority  
Setting  
Description  
Factory Default  
Numerical value selected  
by user  
Increase this device’s bridge priority by  
selecting a lower number. A device with a  
higher bridge priority has a greater chance of  
being established as the root of the Spanning  
Tree topology.  
32768  
Forwarding Delay  
Setting  
Description  
Factory Default  
Numerical value input by  
user  
The amount of time this device waits before  
checking to see if it should change to a  
different state.  
15 (sec.)  
Hello time (sec.)  
Setting  
Description  
Factory Default  
Numerical value input by  
user  
The root of the Spanning Tree topology  
periodically sends out a “hello” message to  
other devices on the network to check if the  
topology is healthy. The “hello time” is the  
amount of time the root waits between sending  
hello messages.  
2
Max. Age (sec.)  
Setting  
Description  
Factory Default  
Numerical value input by  
user  
If this device is not the root, and it has not  
received a hello message from the root in an  
amount of time equal to “Max. Age,” then this  
device will reconfigure itself as a root. Once  
two or more devices on the network are  
recognized as a root, the devices will  
renegotiate to set up a new Spanning Tree  
topology.  
20  
3-27  
Download from Www.Somanuals.com. All Manuals Search And Download.  
EDS-518A Series User’s Manual  
Featured Functions  
Enable STP per Port  
Setting  
Description  
Factory Default  
Enable/Disable  
Select to enable the port as a node on the  
Spanning Tree topology.  
Disabled  
We suggest not enabling the Spanning Tree Protocol once the port is connected to a device (PLC,  
RTU, etc.) as opposed to network equipment. The reason is that it will cause unnecessary  
negotiation.  
NOTE  
Port Priority  
Setting  
Description  
Factory Default  
128  
Numerical value selected  
by user  
Increase this port’s priority as a node on the  
Spanning Tree topology by entering a lower  
number.  
Port Cost  
Setting  
Description  
Factory Default  
Numerical value input by  
user  
Input a higher cost to indicate that this port is  
less suitable as a node for the Spanning Tree  
topology.  
200000  
Port Status  
Indicates the current Spanning Tree status of this port. “Forwarding” for normal transmission, or  
“Blocking” to block transmission.  
Configuration Limits of RSTP/STP  
The Spanning Tree Algorithm places limits on three of the configuration items described  
previously:  
[Eq. 1]: 1 sec Hello Time 10 sec  
[Eq. 2]: 6 sec Max. Age 40 sec  
[Eq. 3]: 4 sec Forwarding Delay 30 sec  
These three variables are further restricted by the following two inequalities:  
[Eq. 4]: 2 * (Hello Time + 1 sec) Max. Age 2 * (Forwarding Delay – 1 sec)  
MOXA EDS-518A’s firmware will alert you immediately if any of these restrictions are violated.  
For example, setting  
Hello Time = 5 sec, Max. Age = 20 sec, and Forwarding Delay = 4 sec does not violate Eqs. 1  
through 3, but does violate Eq. 4, since in this case,  
2 * (Hello Time + 1 sec) = 12 sec, and 2 * (Forwarding Delay – 1 sec) = 6 sec.  
You can remedy the situation in many ways. One solution is simply to increase the Forwarding  
Delay value to at least 11 sec.  
HINT: Perform the following steps to avoid guessing:  
Step 1: Assign a value to “Hello Time” and then calculate the left most part of Eq. 4 to get the  
lower limit of “Max. Age.”  
Step 2: Assign a value to “Forwarding Delay” and then calculate the right most part of Eq. 4 to get  
the upper limit for “Max. Age.”  
Step 3: Assign a value to “Forwarding Delay” that satisfies the conditions in Eq. 3 and Eq. 4.  
3-28  
Download from Www.Somanuals.com. All Manuals Search And Download.  
EDS-518A Series User’s Manual  
Featured Functions  
Using Traffic Prioritization  
EDS-518A’s traffic prioritization capability provides Quality of Service (QoS) to your network by  
making data delivery more reliable. You can prioritize traffic on your network to ensure that high  
priority data is transmitted with minimum delay. Traffic can be controlled by a set of rules to  
obtain the required Quality of Service for your network. The rules define different types of traffic  
and specify how each type should be treated as it passes through the switch. MOXA EDS-518A  
can inspect both IEEE 802.1p/1Q layer 2 CoS tags, and even layer 3 TOS information to provide  
consistent classification of the entire network. EDS-518A’s QoS capability improves the  
performance and determinism of industrial networks for mission critical applications.  
The Traffic Prioritization Concept  
What is Traffic Prioritization?  
Traffic prioritization allows you to prioritize data so that time-sensitive and system-critical data  
can be transferred smoothly and with minimal delay over a network. The benefits of using traffic  
prioritization are:  
y
y
y
y
Improve network performance by controlling a wide variety of traffic and managing  
congestion.  
Assign priorities to different categories of traffic. For example, set higher priorities for  
time-critical or business-critical applications.  
Provide predictable throughput for multimedia applications, such as video conferencing or  
voice over IP, and minimize traffic delay and jitter.  
Improve network performance as the amount of traffic grows. This will save cost by reducing  
the need to keep adding bandwidth to the network.  
How Traffic Prioritization Works  
Traffic prioritization uses the four traffic queues that are present in your EDS-518A to ensure that  
high priority traffic is forwarded on a different queue from lower priority traffic. This is what  
provides Quality of Service (QoS) to your network.  
EDS-518A traffic prioritization depends on two industry-standard methods:  
y
y
IEEE 802.1D—a layer 2 marking scheme.  
Differentiated Services (DiffServ)—a layer 3 marking scheme.  
IEEE 802.1D Traffic Marking  
The IEEE Std 802.1D, 1998 Edition marking scheme, which is an enhancement to IEEE Std  
802.1D, enables Quality of Service on the LAN. Traffic service levels are defined in the IEEE  
802.1Q 4-byte tag, which is used to carry VLAN identification as well as IEEE 802.1p priority  
information. The 4-byte tag immediately follows the destination MAC address and Source MAC  
address.  
The IEEE Std 802.1D, 1998 Edition priority marking scheme assigns an IEEE 802.1p priority  
level between 0 and 7 to each frame. This determines the level of service that that type of traffic  
should receive. Refer to the table below for an example of how different traffic types can be  
mapped to the eight IEEE 802.1p priority levels.  
3-29  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
EDS-518A Series User’s Manual  
Featured Functions  
IEEE 802.1p Priority Level  
IEEE 802.1D Traffic Type  
Best Effort (default)  
0
1
2
3
4
5
Background  
Standard (spare)  
Excellent Effort (business critical)  
Controlled Load (streaming multimedia)  
Video (interactive media); less than 100 milliseconds  
of latency and jitter  
6
7
Voice (interactive voice); less than 10 milliseconds of  
latency and jitter  
Network Control Reserved traffic  
Even though the IEEE 802.1D standard is the most widely used prioritization scheme in the LAN  
environment, it still has some restrictions:  
y
It requires an additional 4-byte tag in the frame, which is normally optional in Ethernet  
networks. Without this tag, the scheme cannot work.  
y
The tag is part of the IEEE 802.1Q header, so to implement QoS at layer 2, the entire network  
must implement IEEE 802.1Q VLAN tagging.  
It is only supported on a LAN and not routed across WAN links, since the IEEE 802.1Q tags are  
removed when the packets pass through a router.  
Differentiated Services (DiffServ) Traffic Marking  
DiffServ is a Layer 3 marking scheme that uses the DiffServ Code Point (DSCP) field in the IP  
header to store the packet priority information. DSCP is an advanced intelligent method of traffic  
marking as you can choose how your network prioritizes different types of traffic. DSCP uses 64  
values that map to user-defined service levels, allowing you to establish more control over  
network traffic.  
Advantages of DiffServ over IEEE 802.1D are:  
y
Configure how you want your switch to treat selected applications and types of traffic by  
assigning various grades of network service to them.  
y
y
y
No extra tags are required in the packet.  
DSCP uses the IP header of a packet and therefore priority is preserved across the Internet.  
DSCP is backward compatible with IPV4 TOS, which allows operation with existing devices  
that use a layer 3 TOS enabled prioritization scheme.  
Traffic Prioritization  
EDS-518A classifies traffic based on layer 2 of the OSI 7 layer model, and the switch prioritizes  
received traffic according to the priority information defined in the received packet. Incoming  
traffic is classified based upon the IEEE 802.1D frame and is assigned to the appropriate priority  
queue based on the IEEE 802.1p service level value defined in that packet. Service level markings  
(values) are defined in the IEEE 802.1Q 4-byte tag, and consequently traffic will only contain  
802.1p priority markings if the network is configured with VLANs and VLAN tagging. The traffic  
flow through the switch is as follows:  
1. A packet received by the EDS-518A may or may not have an 802.1p tag associated with it. If  
it does not, then it is given a default 802.1p tag (which is usually 0). Alternatively, the packet  
may be marked with a new 802.1p value, which will result in all knowledge of the old 802.1p  
tag being lost.  
3-30  
Download from Www.Somanuals.com. All Manuals Search And Download.  
EDS-518A Series User’s Manual  
Featured Functions  
2. As the 802.1p priority levels are fixed to the traffic queues, the packet will be placed in the  
appropriate priority queue, ready for transmission through the appropriate egress port. When  
the packet reaches the head of its queue and is about to be transmitted, the device determines  
whether or not the egress port is tagged for that VLAN. If it is, then the new 802.1p tag is  
used in the extended 802.1D header.  
The EDS-518A will check a packet received at the ingress port for IEEE 802.1D traffic  
classification, and then prioritize it based upon the IEEE 802.1p value (service levels) in that tag.  
It is this 802.1p value that determines to which traffic queue the packet is mapped.  
Traffic Queues  
The EDS-518A hardware has multiple traffic queues that allow packet prioritization to occur.  
Higher priority traffic can pass through the EDS-518A without being delayed by lower priority  
traffic. As each packet arrives in the EDS-518A, it passes through any ingress processing (which  
includes classification, marking/re-marking), and is then sorted into the appropriate queue. The  
switch then forwards packets from each queue.  
EDS-518A supports two different queuing mechanisms:  
y
Weight Fair: This method services all the traffic queues, giving priority to the higher priority  
queues. Under most circumstances, this method gives high priority precedence over  
low-priority, but in the event that high-priority traffic exceeds the link capacity, lower priority  
traffic is not blocked.  
y
Strict: This method services high traffic queues first; low priority queues are delayed until no  
more high priority data needs to be sent. This method always gives precedence to high priority  
over low-priority.  
Configuring Traffic Prioritization  
Quality of Service (QoS) provides a traffic prioritization capability to ensure that important data is  
delivered consistently and predictably. EDS-518A Series can inspect IEEE 802.1p/1Q layer 2 CoS  
tags, and even layer 3 TOS information, to provide a consistent classification of the entire network.  
EDS-518A Series’ QoS capability improves your industrial network’s performance and  
determinism for mission critical applications.  
QoS Classification  
MOXA EDS-518A supports inspection of layer 3 TOS and/or layer 2 CoS tag information to  
determine how to classify traffic packets.  
3-31  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
EDS-518A Series User’s Manual  
Featured Functions  
Queuing Mechanism  
Setting  
Description  
Factory Default  
Weighted Fair  
EDS-518A has 4 priority queues. In the weighted fair  
scheme, an 8, 4, 2, 1 weighting is applied to the four  
priorities. This approach prevents the lower priority  
frames from being starved of opportunity for  
transmission with only a slight delay to the higher  
priority frames.  
Weight Fair  
Strict  
In the Strict-priority scheme, all top-priority frames  
egress a port until that priority’s queue is empty, and  
then the next lower priority queue’s frames egress. This  
approach can cause the lower priorities to be starved of  
opportunity for transmitting any frames but ensures all  
high priority frames to egress the switch as soon as  
possible.  
Port Highest Priority  
Setting  
Description  
Factory Default  
Enable/Disable  
Set the Port Priority of the ingress frames to “High”  
queues.  
Disable  
Inspect TOS  
Setting  
Description  
Factory Default  
Enable/Disable  
Select the option to enable EDS-518A to inspect the  
Type of Service (TOS) bits in IPV4 frame to determine  
the priority of each frame.  
Enable  
Inspect COS  
Setting  
Description  
Factory Default  
Enable/Disable  
Select the option to enable EDS-518A to inspect the  
802.1p COS tag in the MAC frame to determine the  
priority of each frame.  
Enable  
The priority of an ingress frame is determined in order by:  
NOTE  
NOTE  
1. Port Highest Priority  
2. Inspect TOS  
3. Inspect CoS  
The designer can enable these classifications individually or in combination. For instance, if a  
‘hot,’ higher priority port is required for a network design, “Inspect TOS” and “Inspect CoS” can  
be disabled. This setting leaves only port default priority active, which results in all ingress  
frames being assigned the same priority on that port.  
3-32  
Download from Www.Somanuals.com. All Manuals Search And Download.  
EDS-518A Series User’s Manual  
CoS Mapping  
Featured Functions  
Setting  
Description  
Factory  
Low/Normal/  
Medium/High  
Set the mapping table of different CoS values to 4  
different egress queues.  
0: Low  
1: Low  
2: Normal  
3: Normal  
4: Medium  
5: Medium  
6: High  
7: High  
TOS/DiffServ Mapping  
Setting  
Description  
Factory Default  
Low/Normal/  
Medium/High  
Set the mapping table of different TOS values to 4  
different egress queues.  
1 to 16: Low  
17 to 32: Normal  
33 to 48: Medium  
49 to 64: High  
3-33  
Download from Www.Somanuals.com. All Manuals Search And Download.  
EDS-518A Series User’s Manual  
Featured Functions  
Using Virtual LAN  
Setting up Virtual LANs (VLANs) on your EDS-518A increases the efficiency of your network by  
dividing the LAN into logical segments, as opposed to physical segments. In general, VLANs are  
easier to manage.  
The Virtual LAN (VLAN) Concept  
What is a VLAN?  
A VLAN is a group of devices that can be located anywhere on a network, but which  
communicate as if they are on the same physical segment. With VLANs, you can segment your  
network without being restricted by physical connections—a limitation of traditional network  
design. As an example, with VLANs you can segment your network according to:  
y
y
y
Departmental groups—You could have one VLAN for the Marketing department, another  
for the Finance department, and another for the Development department.  
Hierarchical groups—You could have one VLAN for directors, another for managers, and  
another for general staff.  
Usage groups—You could have one VLAN for e-mail users, and another for multimedia  
users.  
Switch A  
5
6
7
8
1
2
3
4
Backbone connects multiple switches  
Switch B  
5
6
7
8
1
2
3
4
Department 3  
VLAN 3  
Department 1  
VLAN 1  
Department 2  
VLAN 2  
Benefits of VLANs  
The main benefit of VLANs is that they provide a network segmentation system that is far more  
flexible than traditional networks. Using VLANs also provides you with three other benefits:  
y
VLANs ease the relocation of devices on networks: With traditional networks, network  
administrators spend most of their time dealing with moves and changes. If users move to a  
different subnetwork, the addresses of each host must be updated manually. With a VLAN  
setup, if a host on VLAN Marketing, for example, is moved to a port in another part of the  
network, and retains its original subnet membership, you only need to specify that the new  
port is on VLAN Marketing. You do not need to carry out any re-cabling.  
3-34  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
EDS-518A Series User’s Manual  
Featured Functions  
y
VLANs provide extra security: Devices within each VLAN can only communicate with  
other devices on the same VLAN. If a device on VLAN Marketing needs to communicate  
with devices on VLAN Finance, the traffic must pass through a routing device or Layer 3  
switch.  
y
VLANs help control traffic: With traditional networks, congestion can be caused by  
broadcast traffic that is directed to all network devices, regardless of whether or not they need  
it. VLANs increase the efficiency of your network because each VLAN can be set up to  
contain only those devices that need to communicate with each other.  
VLANs and MOXA EtherDevice Switch  
Your EDS-518A provides support for VLANs using IEEE Std 802.1Q-1998. This standard allows  
traffic from multiple VLANs to be carried across one physical link. The IEEE Std 802.1Q-1998  
standard allows each port on your EDS-518A to be placed in:  
y
y
Any one VLAN defined on the EDS-518A.  
Several VLANs at the same time using 802.1Q tagging.  
The standard requires that you define the 802.1Q VLAN ID for each VLAN on your EDS-518A  
before the switch can use it to forward traffic:  
Managing a VLAN  
A new or initialized EDS-518A contains a single VLAN—the Default VLAN. This VLAN has the  
following definition:  
y
y
VLAN Name—Management VLAN  
802.1Q VLAN ID—1 (if tagging is required)  
All the ports are initially placed on this VLAN, and it is the only VLAN that allows you to access  
the management software of the EDS-518A over the network.  
Communication Between VLANs  
If devices connected to a VLAN need to communicate to devices on a different VLAN, a router or  
Layer 3 switching device with connections to both VLANs needs to be installed. Communication  
between VLANs can only take place if they are all connected to a routing or Layer 3 switching  
device.  
VLANs: Tagged and Untagged Membership  
EDS-518A supports 802.1Q VLAN tagging, a system that allows traffic for multiple VLANs to be  
carried on a single physical (backbone, trunk) link. When setting up VLANs you need to  
understand when to use untagged and tagged membership of VLANs. Simply put, if a port is on a  
single VLAN it can be an untagged member, but if the port needs to be a member of multiple  
VLANs, tagged membership must be defined.  
A typical host (e.g., clients) will be untagged members of one VLAN, defined as “Access Port” in  
EDS-518A, while inter-switch connections will be tagged members of all VLANs, defined as  
“Trunk Port” in EDS-518A.  
The IEEE Std 802.1Q-1998 defines how VLANs operate within an open packet-switched network.  
An 802.1Q compliant packet carries additional information that allows a switch to determine  
which VLAN the port belongs. If a frame is carrying the additional information, it is known as a  
tagged frame.  
To carry multiple VLANs across a single physical (backbone, trunk) link, each packet must be  
tagged with a VLAN identifier so that the switches can identify which packets belong to which  
VLAN. To communicate between VLANs, a router must be used.  
MOXA EDS-518A supports two types of VLAN port settings:  
3-35  
Download from Www.Somanuals.com. All Manuals Search And Download.  
EDS-518A Series User’s Manual  
Featured Functions  
y
Access Port: The port connects to a single device that is not tagged. The user must define the  
default port PVID that determines to which VLAN the device belongs. Once the ingress  
packet of this Access Port egresses to another Trunk Port (the port needs all packets to carry  
tag information), EDS-518A will insert this PVID into this packet to help the next 802.1Q  
VLAN switch recognize it.  
y
Trunk Port: The port connects to a LAN that consists of untagged devices/tagged devices  
and/or switches and hubs. In general, the traffic of the Trunk Port must have a Tag. Users can  
also assign PVID to a Trunk Port. The untagged packet on the Trunk Port will be assigned the  
port default PVID as its VID.  
The following section illustrates how to use these ports to set up different applications.  
Sample Applications of VLANs using MOXA EDS-518A  
Device I  
VLAN 4 Untagged  
Device  
Port 7 (Access Port  
PVID 4)  
Device A  
VLAN 5 Untagged Device  
Switch A  
Switch B  
Port 3 (Trunk Port, PVID 1)  
Port 5 (Access Port  
PVID 3)  
Port 1 (Access Port  
PVID 5)  
Device H  
VLAN 3 Untagged  
Device  
Port 2 (Trunk Port PVID 2,  
Fixed VLAN (Tagged)=3,4)  
Port 6 (Access Port PVID 5)  
Port 4 (Access  
Port PVID 2)  
HUB  
Device F  
VLAN 2 Untagged  
Device  
Device G  
VLAN 5 Untagged Device  
Device E  
VLAN 4 Tagged Device, VID 4  
Device D  
VLAN 3 Tagged Device, VID 3  
Device B  
VLAN 2 Untagged  
Device  
Device C  
VLAN 2 Untagged  
Device  
In this application,  
y
Port 1 connects a single untagged device and assigns it to VLAN 5; it should be configured as  
“Access Port” with PVID 5.  
y
Port 2 connects a LAN with two untagged devices belonging to VLAN 2. One tagged device  
with VID 3 and one tagged device with VID 4. It should be configured as “Trunk Port” with  
PVID 2 for untagged device and Fixed VLAN (Tagged) with 3 and 4 for tagged device. Since  
each port can only have one unique PVID, all untagged devices on the same port can only  
belong to the same VLAN.  
y
y
y
Port 3 connects with another switch. It should be configured as “Trunk Port.” GVRP protocol  
will be used through the Trunk Port.  
Port 4 connects a single untagged device and assigns it to VLAN 2; it should be configured as  
“Access Port” with PVID 2.  
Port 5 connects a single untagged device and assigns it to VLAN 3; it should be configured as  
“Access Port” with PVID 3.  
3-36  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
EDS-518A Series User’s Manual  
Featured Functions  
y
y
Port 6 connect a single untagged device and assigns it to VLAN 5; it should be configured as  
“Access Port” with PVID 5.  
Port 7 connects a single untagged device and assigns it to VLAN 4; it should be configured as  
“Access Port” with PVID 4.  
After proper configuration:  
y
y
y
Packets from device A will travel through “Trunk Port 3” with tagged VID 5. Switch B will  
recognize its VLAN, pass it to port 6, and then remove tags received successfully by device G,  
and vice versa.  
Packets from device B and C will travel through “Trunk Port 3” with tagged VID 2. Switch B  
recognizes its VLAN, passes it to port 4, and then removes tags received successfully by  
device F, and vice versa.  
Packets from device D will travel through “Trunk Port 3” with tagged VID 3. Switch B will  
recognize its VLAN, pass to port 5, and then remove tags received successfully by device H.  
Packets from device H will travel through “Trunk Port 3” with PVID 3. Switch A will  
recognize its VLAN and pass it to port 2, but will not remove tags received successfully by  
device D.  
y
Packets from device E will travel through “Trunk Port 3” with tagged VID 4. Switch B will  
recognize its VLAN, pass it to port 7, and then remove tags received successfully by device I.  
Packets from device I will travel through “Trunk Port 3” with tagged VID 4. Switch A will  
recognize its VLAN and pass it to port 2, but will not remove tags received successfully by  
device E.  
Configuring Virtual LAN  
VLAN Settings  
To configure EDS-518A’s 802.1Q VLAN, use the VLAN Setting page to configure the ports.  
VLAN Mode  
Setting  
Description  
Factory Default  
802.1Q VLAN  
Set VLAN mode to 802.1Q VLAN  
802.1Q VLAN  
Port-based VLAN Set VLAN mode to Port-based VLAN  
3-37  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
EDS-518A Series User’s Manual  
Featured Functions  
Management VLAN ID  
Setting  
Description  
Factory Default  
VLAN ID  
ranges from  
1 to 4094  
Set the management VLAN of this EDS-518A.  
1
Port Type  
Setting  
Description  
Factory Default  
Access  
This port type is used to connect single devices without  
tags.  
Trunk  
Select “Trunk” port type to connect another 802.1Q  
VLAN aware switch or another LAN that combines  
tagged and/or untagged devices and/or other  
switches/hubs.  
Access  
ATTENTION  
For communication redundancy in the VLAN environment, set “Redundant Port,” “Coupling  
Port,” and “Coupling Control Port” as “Trunk Port,” since these ports act as the “backbone” to  
transmit all packets of different VLANs to different EDS-518A units.  
Port PVID  
Setting  
VID range from 1 Set the port default VLAN ID for untagged devices that  
to 4094 connect to the port.  
Description  
Factory Default  
1
Fixed VLAN List (Tagged)  
Setting  
Description  
Factory Default  
VID range from 1 This field will be active only when selecting the “Trunk” None  
to 4094  
port type. Set the other VLAN ID for tagged devices that  
connect to the “Trunk” port. Use commas to separate  
different VIDs.  
Forbidden VLAN List  
Setting  
Description  
Factory Default  
VID range from 1 This field will be active only when selecting the “Trunk” None  
to 4094  
port type. Set the VLAN IDs that will not be supported  
by this trunk port. Use commas to separate different  
VIDs.  
To configure EDS-518A’s Port-based VLAN, use the VLAN Setting page to configure the ports.  
3-38  
Download from Www.Somanuals.com. All Manuals Search And Download.  
EDS-518A Series User’s Manual  
Featured Functions  
VLAN Mode  
Setting  
Description  
Set VLAN mode to 802.1Q VLAN  
Factory Default  
802.1Q VLAN  
802.1Q VLAN  
Port-based VLAN Set VLAN mode to Port-based VLAN  
Port  
Setting  
Description  
Factory Default  
Enable/Disable  
Set port to specific VLAN Group.  
Enable  
(all ports belong to  
VLAN1)  
VLAN Table  
In 802.1Q VLAN table, you can review the VLAN groups that were created, Joined Access Ports,  
and Trunk Ports, and in Port-based VLAN table, you can review the VLAN group and Joined port.  
3-39  
Download from Www.Somanuals.com. All Manuals Search And Download.  
EDS-518A Series User’s Manual  
Featured Functions  
The physical network can have a maximum of 64 VLAN settings.  
NOTE  
Using Multicast Filtering  
Multicast filtering improves the performance of networks that carry multicast traffic. This section  
explains multicasts, multicast filtering, and how multicast filtering can be implemented on your  
EDS-518A.  
The Concept of Multicast Filtering  
What is an IP Multicast?  
A multicast is a packet sent by one host to multiple hosts. Only those hosts that belong to a  
specific multicast group will receive the multicast. If the network is set up correctly, a multicast  
can only be sent to an end-station or a subset of end-stations on a LAN or VLAN that belong to  
the multicast group. Multicast group members can be distributed across multiple subnets, so that  
multicast transmissions can occur within a campus LAN or over a WAN. In addition, networks  
that support IP multicast send only one copy of the desired information across the network until  
the delivery path that reaches group members diverges. To make more efficient use of network  
bandwidth, it is only at these points that multicast packets are duplicated and forwarded. A  
multicast packet has a multicast group address in the destination address field of the packet’s IP  
header.  
Benefits of Multicast  
The benefits of using IP multicast are that it:  
y
y
y
y
Uses the most efficient, sensible method to deliver the same information to many receivers  
with only one transmission.  
Reduces the load on the source (for example, a server) since it will not need to produce  
several copies of the same data.  
Makes efficient use of network bandwidth and scales well as the number of multicast group  
members increases.  
Works with other IP protocols and services, such as Quality of Service (QoS).  
Multicast transmission makes more sense and is more efficient than unicast transmission for some  
applications. For example, multicasts are often used for video-conferencing, since high volumes of  
traffic must be sent to several end-stations at the same time, but where broadcasting the traffic to  
all end-stations would cause a substantial reduction in network performance. Furthermore, several  
industrial automation protocols, such as Allen-Bradley, EtherNet/IP, Siemens Profibus, and  
Foundation Fieldbus HSE (High Speed Ethernet), use multicast. These industrial Ethernet  
protocols use publisher/subscriber communications models by multicasting packets that could  
flood a network with heavy traffic. IGMP Snooping is used to prune multicast traffic so that it  
travels only to those end destinations that require the traffic, reducing the amount of traffic on the  
Ethernet LAN.  
Multicast Filtering  
Multicast filtering ensures that only end-stations that have joined certain groups receive multicast  
traffic. With multicast filtering, network devices only forward multicast traffic to the ports that are  
connected to registered end-stations. The following two figures illustrate how a network behaves  
without multicast filtering, and with multicast filtering.  
3-40  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
EDS-518A Series User’s Manual  
Network without multicast filtering  
Featured Functions  
Group 1 Multicast Stream  
Group 2 Multicast Stream  
Serial ports  
Console  
LAN  
1
2
3
4
5
6
7
8
9
10  
11  
12  
13  
14  
15  
16  
IGMP Group2 IGMP Group1 IGMP Group2 IGMP Group1  
All hosts receive the multicast traffic, even if they don’t need it.  
Network with multicast filtering  
Group 1 Multicast Stream  
Group 2 Multicast Stream  
IGMP Group2 IGMP Group1 IGMP Group2 IGMP Group1  
Hosts only receive dedicated traffic from other hosts belonging to the same group.  
Multicast Filtering and MOXA EtherDevice Switch  
EDS-518A has three ways to achieve multicast filtering: IGMP (Internet Group Management  
Protocol) Snooping, GMRP (GARP Multicast Registration Protocol), and adding a static multicast  
MAC manually to filter multicast traffic automatically.  
IGMP (Internet Group Management Protocol)  
Snooping Mode  
Snooping Mode allows your switch to forward multicast packets only to the appropriate ports. The  
switch “snoops” on exchanges between hosts and an IGMP device, such as a router, to find those  
ports that want to join a multicast group, and then configures its filters accordingly.  
3-41  
Download from Www.Somanuals.com. All Manuals Search And Download.  
EDS-518A Series User’s Manual  
Featured Functions  
Query Mode  
Query mode allows the EDS-518A to work as the Querier if it has the lowest IP address on the  
subnetwork to which it belongs. IGMP querying is enabled by default on the EDS-518A to help  
prevent interoperability issues with some multicast routers that may not follow the lowest IP  
address election method. Enable query mode to run multicast sessions on a network that does not  
contain IGMP routers (or queriers).  
EDS-518A is compatible with any device that conforms to the IGMP v2 and IGMP v3 device  
protocol.  
NOTE  
IGMP Multicast Filtering  
IGMP is used by IP-supporting network devices to register hosts with multicast groups. It can be  
used on all LANs and VLANs that contain a multicast capable IP router, and on other network  
devices that support multicast filtering. IGMP works as follows:  
1. The IP router (or querier) periodically sends query packets to all end-stations on the LANs or  
VLANs that are connected to it. For networks with more than one IP router, the router with  
the lowest IP address is the querier. A switch with IP address lower than the IP address of any  
other IGMP queriers connected to the LAN or VLAN can become the IGMP querier.  
2. When an IP host receives a query packet, it sends a report packet back that identifies the  
multicast group that the end-station would like to join.  
3. When the report packet arrives at a port on a switch with IGMP Snooping enabled, the switch  
knows that the port should forward traffic for the multicast group, and then proceeds to  
forward the packet to the router.  
4. When the router receives the report packet, it registers that the LAN or VLAN requires traffic  
for the multicast groups.  
5. When the router forwards traffic for the multicast group to the LAN or VLAN, the switches  
only forward the traffic to ports that received a report packet.  
GMRP (GARP Multicast Registration Protocol)  
EDS-518A supports IEEE 802.1D-1998 GMRP (GARP Multicast Registration Protocol), which  
differs from IGMP (Internet Group Management Protocol). GMRP is a MAC-based multicast  
management protocol, whereas IGMP is IP-based. GMRP provides a mechanism that allows  
bridges and end stations to register or de-register Group membership information dynamically.  
GMRP functions similarly to GVRP, except that GMRP registers multicast addresses on ports.  
When a port receives a GMRP-join message, it will register the multicast address to its database if  
the multicast address is not registered, and all the multicast packets with that multicast address are  
able to be forwarded from this port. When a port receives a GMRP-leave message, it will  
de-register the multicast address from its database, and all the multicast packets with this multicast  
address are not able to be forwarded from this port.  
Static Multicast MAC  
Some devices may only support multicast packets, but not support either IGMP Snooping or  
GMRP. MOXA EDS-518A supports adding multicast groups manually to enable multicast  
filtering.  
3-42  
Download from Www.Somanuals.com. All Manuals Search And Download.  
EDS-518A Series User’s Manual  
Enabling Multicast Filtering  
Featured Functions  
Use the serial console or Web interface to enable or disable IGMP Snooping and IGMP querying.  
If IGMP Snooping is not enabled, then IP multicast traffic is always forwarded, flooding the  
network.  
Configuring IGMP Snooping  
IGMP Snooping provides the ability to prune multicast traffic so that it travels only to those end  
destinations that require that traffic, thereby reducing the amount of traffic on the Ethernet LAN.  
IGMP Snooping Settings  
IGMP Snooping Enable  
Setting  
Description  
Factory Default  
Enable/Disable  
Select the option to enable the IGMP Snooping function Disabled  
globally.  
Query Interval  
Setting  
Description  
Factory Default  
Numerical value Set the query interval of the Querier function globally.  
125 seconds  
input by user  
Valid settings are from 20 to 600 seconds.  
IGMP Snooping  
Setting  
Description  
Factory Default  
Enable/Disable  
Select the option to enable the IGMP Snooping function Enabled if IGMP  
per VLAN.  
Snooping Enabled  
Globally  
Querier  
Setting  
Description  
Factory Default  
Enable/Disable  
Select the option to enable EDS-518A’s querier  
function.  
Enabled if IGMP  
Snooping is  
Enabled Globally  
3-43  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
EDS-518A Series User’s Manual  
Featured Functions  
Static Multicast Router Port  
Setting  
Description  
Factory Default  
Select/Deselect  
Select the option to select which ports will connect to  
the multicast routers. It’s active only when IGMP  
Snooping is enabled.  
Disabled  
At least one switch must be designated the Querier or enable IGMP snooping and GMRP when  
enabling Turbo Ring and IGMP snooping simultaneously.  
NOTE  
IGMP Table  
EDS-518A displays the current active IGMP groups that were detected.  
The information includes VID, Auto-learned Multicast Router Port, Static Multicast Router  
Port, Querier Connected Port, and the IP and MAC addresses of active IGMP groups.  
Add Static Multicast MAC  
If required, MOXA EDS-518A also supports adding multicast groups manually.  
Add New Static Multicast Address to the List  
Setting  
Description  
Factory Default  
MAC Address  
Input the multicast MAC address of this host.  
None  
MAC Address  
Setting  
Description  
Factory Default  
integer  
Input the number of the VLAN to which the host with  
this MAC Address belongs.  
None  
3-44  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
EDS-518A Series User’s Manual  
Featured Functions  
Join Port  
Setting  
Description  
Factory Default  
Select/Deselect  
Select the appropriate options to select the join ports for None  
this multicast group.  
Configuring GMRP  
GMRP is a MAC-based multicast management protocol, whereas IGMP is IP-based. GMRP  
provides a mechanism that allows bridges and end stations to register or un-register Group  
membership information dynamically.  
GMRP enable  
Setting  
Description  
Factory Default  
Enable/Disable  
Select the option to enable the GMRP function for the  
port listed in the Port column  
Disable  
GMRP Table  
EDS-518A displays the current active GMRP groups that were detected.  
Setting  
Fixed Ports  
Description  
This multicast address is defined by static multicast.  
This multicast address is learned by GMRP.  
Learned Ports  
3-45  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
EDS-518A Series User’s Manual  
Featured Functions  
Using Bandwidth Management  
In general, one host should not be allowed to occupy unlimited bandwidth, particularly when the  
device malfunctions. For example, so-called “broadcast storms” could be caused by an incorrectly  
configured topology, or a malfunctioning device. The EDS-518A series not only prevents  
broadcast storms, but can also be configured to a different ingress rate for all packets, giving  
administrators full control of their limited bandwidth to prevent undesirable effects caused by  
unpredictable faults.  
Configuring Bandwidth Management  
Broadcast Storm Protection  
Setting  
Description  
Factory Default  
Enable/Disable  
Enable or disable the Broadcast Storm Protection for  
multicast packet globally.  
Enable  
(for unknown  
multicast and  
unknown unicast  
packet)  
Enable or disable the Broadcast Storm Protection for  
unknown multicast and unknown unicast packets  
globally.  
Traffic Rate Limiting Settings  
3-46  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
EDS-518A Series User’s Manual  
Featured Functions  
Ingress  
Setting  
Description  
Factory Default  
Ingress rate  
Select the ingress rate for all packets from the following N/A  
options: not limited, 3%, 5%, 10%, 15%, 25%, 35%,  
50%, 65%, 85%  
Using Port Access Control  
EDS-518A provides two kinds of Port-Based Access Controls. One is Static Port Lock and the  
other is IEEE 802.1X.  
Static Port Lock  
EDS-518A can also be configured to protect static MAC addresses for a specific port. With the  
Port Lock function, these locked ports will not learn any additional addresses, but only allow  
traffic from preset static MAC addresses, helping to block crackers and careless usage.  
IEEE 802.1X  
The IEEE 802.1X standard defines a protocol for client/server-based access control and  
authentication. The protocol restricts unauthorized clients from connecting to a LAN through ports  
that are open to the Internet, and which otherwise would be readily accessible. The purpose of the  
authentication server is to check each client that requests access to the port. The client is only  
allowed access to the port if the client’s permission is authenticated.  
The IEEE 802.1X Concept  
Three components are used to create an authentication mechanism based on 802.1X standards:  
Client/Supplicant, Authentication Server, and Authenticator.  
Supplicant: The end station that requests access to the LAN and switch services and responds to  
the requests from the switch.  
Authentication server: The server that performs the actual authentication of the supplicant.  
Authenticator: Edge switch or wireless access point that acts as a proxy between the supplicant  
and the authentication server, requesting identity information from the supplicant, verifying the  
information with the authentication server, and relaying a response to the supplicant.  
EDS-518A acts as an authenticator in the 802.1X environment. A supplicant and an authenticator  
exchange EAPOL (Extensible Authentication Protocol over LAN) frames with each other. We can  
either use an external RADIUS server as the authentication server, or implement the authentication  
server in EDS-518A by using a Local User Database as the authentication look-up table. When we  
use an external RADIUS server as the authentication server, the authenticator and the  
authentication server exchange EAP frames between each other.  
Authentication can be initiated either by the supplicant or the authenticator. When the supplicant  
initiates the authentication process, it sends an “EAPOL-Start” frame to the authenticator. When  
the authenticator initiates the authentication process or when it receives an “EAPOL Start” frame,  
it sends an “EAP Request/Identity” frame to ask for the username of the supplicant. The following  
actions are described below:  
3-47  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
EDS-518A Series User’s Manual  
Featured Functions  
Message Exchange  
Authentication  
server  
Client  
(RADIUS)  
EAPOL-Start  
EAP-Request/Identity  
EAP-Response/Identity  
EAP-Request/OTP  
EAP-Response/OTP  
EAP-Success  
RADIUS Access-Request  
RADIUS Access-Challenge  
RADIUS Access-Request  
RADIUS Access-Accept  
Port Authorized  
EAPOL-Logoff  
Port Unauthorized  
1. When the supplicant receives an “EAP Request/Identity” frame, it sends an “EAP  
Response/Identity” frame with its username back to the authenticator.  
2. If the RADIUS server is used as the authentication server, the authenticator relays the “EAP  
Response/Identity” frame from the supplicant by encapsulating it into a “RADIUS  
Access-Request” frame and sends to the RADIUS server. When the authentication server  
receives the frame, it looks up its database to check if the username exists. If the username is  
not present, the authentication server replies with a “RADIUS Access-Reject” frame to the  
authenticator if the server is a RADIUS server or just indicates failure to the authenticator if  
the Local User Database is used. The authenticator sends an “EAP-Failure” frame to the  
supplicant.  
3. The RADIUS server sends a “RADIUS Access-Challenge,” which contains an “EAP Request”  
with an authentication type to the authenticator to ask for the password from the client. RFC  
2284 defines several EAP authentication types, such as “MD5-Challenge,” “One-Time  
Password,” and “Generic Token Card.” Currently, only “MD5-Challenge” is supported. If the  
Local User Database is used, this step is skipped.  
4. The authenticator sends an “EAP Request/MD5-Challenge” frame to the supplicant. If the  
RADIUS server is used, the “EAP Request/MD5-Challenge” frame is retrieved directly from  
the “RADIUS Access-Challenge” frame.  
5. The supplicant responds to the “EAP Request/MD5-Challenge” by sending an “EAP  
Response/MD5-Challenge” frame that encapsulates the user’s password using the MD5 hash  
algorithm.  
6. If the RADIUS server is used as the authentication server, the authenticator relays the “EAP  
Response/MD5-Challenge” frame from the supplicant by encapsulating it into a “RADIUS  
Access-Request” frame along with a “Shared Secret,” which must be the same within the  
authenticator and the RADIUS server, and sends the frame to the RADIUS server. The  
RADIUS server checks against the password with its database, and replies with “RADIUS  
Access-Accept” or “RADIUS Access-Reject” to the authenticator. If the Local User Database  
is used, the password is checked against its database and indicates success or failure to the  
authenticator.  
3-48  
Download from Www.Somanuals.com. All Manuals Search And Download.  
EDS-518A Series User’s Manual  
Featured Functions  
7. The authenticator sends “EAP Success” or “EAP Failure” based on the reply from the  
authentication server.  
Configuring Static Port Lock  
MOXA EDS-518A supports adding unicast groups manually if required.  
Setting  
Description  
Factory Default  
MAC Address  
Add the static unicast MAC address into the address  
table.  
None  
Port  
Fix the static address with a dedicated port.  
1
Configuring IEEE 802.1X  
Database Option  
Setting  
Description  
Factory Default  
Local  
(Max. 32 users)  
Select this option when setting the Local User Database Local  
as the authentication database.  
Radius  
Select this option to set an external RADIUS server as  
the authentication database. The authentication  
mechanism is “EAP-MD5.”  
Local  
Radius, Local  
Select this option to make an external RADIUS server as Local  
the authentication database with first priority. The  
authentication mechanism is “EAP-MD5.” The first  
priority is to set the Local User Database as the  
authentication database.  
3-49  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
EDS-518A Series User’s Manual  
Featured Functions  
Radius Server  
Setting  
Description  
Factory Default  
IP address or  
domain name  
The IP address or domain name of the RADIUS server localhost  
Server Port  
Setting  
Description  
Factory Default  
Numerical  
The UDP port of the RADIUS Server  
1812  
Shared Key  
Setting  
Description  
Factory Default  
alphanumeric  
(Max. 40  
characters)  
A key to be shared between the external RADIUS server None  
and EDS-518A. Both ends must be configured to use the  
same key.  
Re-Auth  
Setting  
Description  
Factory Default  
Enable/Disable  
Select to require re-authentication of the client after a  
preset time period of no activity has elapsed.  
Disable  
Re-Auth Period  
Setting  
Description  
Factory Default  
Numerical  
(60-65535 sec.)  
Specify how frequently the end stations need to reenter 3600  
usernames and passwords in order to stay connected.  
802.1X  
Setting  
Description  
Factory Default  
Disable  
Enable/Disable  
Select the option under the 802.1X column to enable  
IEEE 802.1X for one or more ports. All end stations  
must enter usernames and passwords before access to  
these ports is allowed.  
3-50  
Download from Www.Somanuals.com. All Manuals Search And Download.  
EDS-518A Series User’s Manual  
802.1X Re-Authentication  
Featured Functions  
EDS-518A can force connected devices to be re-authorized manually.  
802.1X Re-Authentication  
Setting  
Description  
Select the option to enable 802.1X Re-Authentication  
Factory Default  
Enable/Disable  
Disable  
Local User Database Setup  
When setting the Local User Database as the authentication database, set the database first.  
3-51  
Download from Www.Somanuals.com. All Manuals Search And Download.  
EDS-518A Series User’s Manual  
Featured Functions  
Local User Database Setup  
Setting  
Description  
Factory Default  
User Name  
User Name for Local User Database  
None  
(Max. 30 characters)  
Password  
(Max. 16 characters)  
Password for Local User Database  
Description for Local User Database  
None  
None  
Description  
(Max. 30 characters)  
The user name for the Local User Database is case-insensitive.  
NOTE  
Port Access Control Table  
The port status will indicate whether the access is authorized or unauthorized.  
Using Auto Warning  
Since industrial Ethernet devices are often located at the endpoints of a system, these devices will  
not always know what is happening elsewhere on the network. This means that an industrial  
Ethernet switch that connects to these devices must provide system maintainers with real-time  
alarm messages. Even when control engineers are out of the control room for an extended period  
of time, they can still be informed of the status of devices almost instantaneously when exceptions  
occur. MOXA EDS-518A supports different approaches to warn engineers automatically, such as  
by using email and relay output. It also supports two digital inputs to integrate sensors into your  
system to automate alarms using email and relay output.  
3-52  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
EDS-518A Series User’s Manual  
Featured Functions  
Configuring Email Warning  
The Auto Email Warning function uses e-mail to alert the user when certain user-configured  
events take place.  
Three basic steps are required to set up the Auto Warning function:  
1. Configuring Email Event Types  
Select the desired Event types from the Console or Web Browser Event type page (a  
description of each event type is given later in the Email Alarm Events setting subsection).  
2. Configuring Email Settings  
To configure EDS-518A’s email setup from the Console interface or browser interface, enter  
your Mail Server IP/Name (IP address or name), Account Name, Account Password, Retype  
New Password, and the email address to which warning messages will be sent.  
3. Activate your settings and if necessary, test the email  
After configuring and activating your EDS-518A’s Event Types and Email Setup, you can use  
the Test Email function to see if your e-mail addresses and mail server address have been  
properly configured.  
Event Type  
Event Types can be divided into two basic groups: System Events and Port Events. System  
Events are related to the overall function of the switch, whereas Port Events are related to the  
activity of a specific port.  
3-53  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
EDS-518A Series User’s Manual  
Featured Functions  
Warning e-mail is sent when…  
System Events  
Switch Cold Start  
Power is cut off and then reconnected.  
Switch Warm Start  
EDS-518A is rebooted, such as when network  
parameters are changed (IP address, subnet mask,  
etc.).  
Power Transition (OnÆOff)  
Power Transition (OffÆOn)  
DI1 (OnÆOff)  
EDS-518A is powered down.  
EDS-518A is powered up.  
Digital Input 1 is triggered by on to off transition  
Digital Input 1 is triggered by off to on transition  
Digital Input 2 is triggered by on to off transition  
Digital Input 2 is triggered by off to on transition  
DI1 (OffÆOn)  
DI2 (OnÆOff)  
DI2 (OffÆOn)  
Configuration Change Activated A configuration item has been changed.  
Authentication Failure  
An incorrect password is entered.  
Comm. Redundancy Topology  
Changed  
Spanning Tree Protocol switches have changed their  
position (applies only to the root of the tree).  
The Master of the Turbo Ring has changed or the  
backup path is activated.  
Port Events  
Warning e-mail is sent when…  
Link-ON  
The port is connected to another device.  
The port is disconnected (e.g., the cable is pulled out,  
or the opposing device shuts down).  
Link-OFF  
The port’s traffic surpasses the Traffic-Threshold for  
that port (provided this item is Enabled).  
Traffic-Overload  
Traffic-Threshold (%)  
Enter a non-zero number if the port’s  
Traffic-Overload item is Enabled.  
A Traffic-Overload warning is sent every  
Traffic-Duration seconds if the average  
Traffic-Threshold is surpassed during that time  
period.  
Traffic-Duration (sec.)  
The Traffic-Overload, Traffic-Threshold (%), and Traffic-Duration (sec.) Port Event items  
are related. If you Enable the Traffic-Overload event, then be sure to enter a non-zero  
Traffic-Threshold percentage, as well as a Traffic-Duration between 1 and 300 seconds.  
NOTE  
NOTE  
Warning e-mail messages will have the sender field formatted in the form:  
MOXA_EtherDevice_Switch_0001@Switch_Location  
where MOXA_EtherDevice_Switch is the default Switch Name, 0001 is EDS-518A’s serial  
number, and Switch_Location is the default Server Location.  
Refer to the Basic Settings section to see how to modify Switch Name and Switch Location.  
3-54  
Download from Www.Somanuals.com. All Manuals Search And Download.  
EDS-518A Series User’s Manual  
Featured Functions  
Email Setup  
Mail Server IP/Name  
Setting  
Description  
Factory Default  
IP address  
The IP Address of your email server.  
None  
Account Name  
Setting  
Description  
Factory Default  
Max. 45  
Your email account name (typically your user name)  
None  
Characters  
Password Setting  
Setting  
Description  
Factory Default  
Disable/Enable to To reset the Password from the Web Browser interface, Disable  
change Password click the Change password check-box, type the Old  
Password, type the New Password, retype the New  
password, and then click Activate; Max. 45 Characters.  
Old Password  
New Password  
Type the current password when changing the password None  
Type new password when enabled to change password; None  
Max. 45 Characters.  
Retype Password If you type a new password in the Password field, you  
will be required to retype the password in the Retype  
None  
new password field before updating the new password.  
Email Address  
Setting  
Max. 30  
characters  
Description  
Factory Default  
You can set up to 4 email addresses to receive alarm  
emails from EDS-518A.  
None  
Send Test Email  
After configuring the email settings, you should first click Activate to activate those settings, and  
then click Send Test Email to verify that the settings are correct.  
3-55  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
EDS-518A Series User’s Manual  
Featured Functions  
Auto warning e-mail messages will be sent through an authentication protected SMTP server that  
supports the CRAM-MD5, LOGIN, and PLAIN methods of SASL (Simple Authentication and  
Security Layer) authentication mechanism.  
NOTE  
We strongly recommend not entering your Account Name and Account Password if auto warning  
e-mail messages can be delivered without using an authentication mechanism.  
Configuring Relay Warning  
The Auto Relay Warning function uses relay output to alert the user when certain user-configured  
events take place. There are two basic steps required to set up the Relay Warning function:  
1. Configuring Relay Event Types  
Select the desired Event types from the Console or Web Browser Event type page (a  
description of each event type is given later in the Relay Alarm Events setting subsection).  
2. Activate your settings  
After completing the configuration procedure, you will need to activate your EDS-518A’s  
Relay Event Types.  
Event Setup  
Event Types can be divided into two basic groups: System Events and Port Events. System  
Events are related to the overall function of the switch, whereas Port Events are related to the  
activity of a specific port.  
MOXA EDS-518A supports two relay outputs. You can configure which relay output is related to  
which events. This helps administrators identify the importance of the different events.  
3-56  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
EDS-518A Series User’s Manual  
Featured Functions  
Warning Relay output is triggered when…  
System Events  
Power Transition (OnÆOff)  
Power Transition (OffÆOn)  
DI1 (OnÆOff)  
EDS-518A is powered on.  
EDS-518A is powered down.  
Digital Input 1 is triggered by on to off transition  
Digital Input 1 is triggered by off to on transition  
Digital Input 2 is triggered by on to off transition  
Digital Input 2 is triggered by off to on transition  
DI1 (OffÆOn)  
DI2 (OnÆOff)  
DI2 (OffÆOn)  
Port Events  
Warning e-mail is sent when…  
Link-ON  
The port is connected to another device.  
The port is disconnected (e.g., the cable is pulled out,  
or the opposing device shuts down).  
Link-OFF  
The port’s traffic surpasses the Traffic-Threshold for  
that port (provided this item is Enabled).  
Traffic-Overload  
Traffic-Threshold (%)  
Enter a non-zero number if the port’s  
Traffic-Overload item is Enabled.  
A Traffic-Overload warning is sent every  
Traffic-Duration seconds if the average  
Traffic-Threshold is surpassed during that time  
period.  
Traffic-Duration (sec.)  
The Traffic-Overload, Traffic-Threshold (%), and Traffic-Duration (sec) Port Event items  
are related. If you Enable the Traffic-Overload event, then be sure to enter a non-zero  
Traffic-Threshold percentage, as well as a Traffic-Duration between 1 and 300 seconds.  
NOTE  
Override relay alarm settings  
Select this option to override the relay warning setting temporarily. Releasing the relay output will  
allow administrators to fix any problems with the warning condition.  
Warning List  
Use this table to see if any relay alarms have been issued.  
Using Line-Swap-Fast-Recovery  
The Line-Swap Fast Recovery function, which is enabled by default, allows EDS-518A to return  
to normal operation extremely quickly after devices are unplugged and then re-plugged into  
different ports. The recovery time is on the order of a few milliseconds (compare this with  
standard commercial switches for which the recovery time could be on the order of several  
minutes). To disable the Line-Swap Fast Recovery function, or to re-enable the function after it  
has already been disabled, access either the Console utility’s Line-Swap recovery page, or the  
Web Browser interface’s Line-Swap fast recovery page, as the following figure shows:  
3-57  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
EDS-518A Series User’s Manual  
Featured Functions  
Configuring Line-Swap Fast Recovery  
Enable Line-Swap-Fast-Recovery  
Setting  
Description  
Factory Default  
Enable/Disable  
Select this option to enable the  
Enable  
Line-Swap-Fast-Recovery function  
Using Set Device IP  
To reduce the effort required to set up IP addresses, the EDS-518A series comes equipped with  
DHCP/BOOTP server and RARP protocol to set up IP addresses of Ethernet-enabled devices  
automatically.  
When enabled, the Set device IP function allows EDS-518A to assign specific IP addresses  
automatically to connected devices that are equIPped with DHCP Client or RARP protocol. In  
effect, EDS-518A acts as a DHCP server by assigning a connected device with a specific IP  
address stored in its internal memory. Each time the connected device is switched on or rebooted,  
EDS-518A sends the device the desired IP address.  
Perform the following steps to use the Set device IP function:  
STEP 1—set up the connected devices  
Set up those Ethernet-enabled devices connected to  
EDS-518A for which you would like IP addresses to  
be assigned automatically. The devices must be  
configured to obtain their IP address automatically.  
The devices’ configuration utility should include a  
setup page that allows you to choose an option  
similar to Obtain an IP address automatically.  
For example, Windows’ TCP/IP Properties window  
is shown at the right. Although your device’s  
configuration utility may look quite a bit different,  
this figure should give you some idea of what to look  
for.  
You also need to decide to which of EDS-518A’s  
ports your Ethernet-enabled devices will be  
connected. You will need to set up each of these ports  
separately, as described in the following step.  
STEP 2  
Configure EDS-518A’s Set device IP function, either from the Console utility or from the Web  
Browser interface. In either case, you simply need to enter the Desired IP for each port that needs  
to be configured.  
STEP 3  
Be sure to activate your settings before exiting.  
When using the Web Browser interface, activate by clicking Activate.  
3-58  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
EDS-518A Series User’s Manual  
Featured Functions  
When using the Console utility, activate by first highlighting the Activate menu option, and  
then press Enter. You should receive the Set device IP settings are now active! (Press any  
key to continue) message.  
Configuring Set Device IP  
Desired IP Address  
Setting  
Description  
Set the desired IP of connected devices.  
Factory Default  
IP Address  
None  
Using Diagnosis  
MOXA EDS-518A provides two important tools for administrators to diagnose network systems.  
Mirror Port  
The Mirror port function can be used to monitor data being transmitted through a specific port.  
This is done by setting up another port (the mirror port) to receive the same data being transmitted  
from, or both to and from, the port under observation. This allows the network administrator to  
“sniff” the observed port and thus keep tabs on network activity.  
Perform the following steps to set up the Mirror Port function:  
3-59  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
EDS-518A Series User’s Manual  
Featured Functions  
STEP 1  
Configure EDS-518A’s Mirror Port function from either the Console utility or Web Browser  
interface. You will need to configure three settings:  
Monitored Port Select the port number of the port whose network activity will be  
monitored.  
Mirror Port  
Select the port number of the port that will be used to monitor the  
activity of the monitored port.  
Watch Direction Select one of the following two watch direction options:  
y
y
Output data stream  
Select this option to monitor only those data packets being sent out  
through EDS-518A’s port.  
Bi-directional  
Select this option to monitor data packets both coming into, and  
being sent out through, EDS-518A’s port.  
STEP 2  
Be sure to activate your settings before exiting.  
When using the Web Browser interface, activate by clicking Activate.  
When using the Console utility, activate by first highlighting the Activate menu option, and  
then press Enter. You should receive the Mirror port settings are now active! (Press any  
key to continue) message.  
Ping  
The Ping function uses the ping command to give users a simple but powerful tool for  
troubleshooting network problems. The function’s most unique feature is that even though the  
ping command is entered from the user’s PC keyboard, the actual ping command originates from  
EDS-518A itself. In this way, the user can essentially control EDS-518A and send ping commands  
out through its ports.  
To use the Ping function, type in the desired IP address, and then press Enter from the Console  
utility, or click Ping when using the Web Browser interface.  
Using Monitor  
You can monitor statistics in real time from EDS-518A’s web console and serial console.  
Monitor by Switch  
Access the Monitor by selecting “System” from the left selection bar. Monitor by System allows  
the user to view a graph that shows the combined data transmission activity of all EDS-518A’s 18  
ports. Click one of the four options—Total Packets, TX Packets, RX Packets, or Error  
Packets—to view transmission activity of specific types of packets. Recall that TX Packets are  
packets sent out from EDS-518A, RX Packets are packets received from connected devices, and  
Error Packets are packets that did not pass TCP/IP’s error checking algorithm. The Total Packets  
option displays a graph that combines TX, RX, and TX Error, RX Error Packets activity. The  
3-60  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
EDS-518A Series User’s Manual  
Featured Functions  
graph displays data transmission activity by showing Packets/s (i.e., packets per second, or pps)  
versus sec. (seconds). In fact, three curves are displayed on the same graph: Unicast packets (in  
red color), Multicast packets (in green color), and Broadcast packets (in blue color). The graph is  
updated every few seconds, allowing the user to analyze data transmission activity in real-time.  
Monitor by Port  
Access the Monitor by Port function by selecting ALL 10/100M or 1G Ports or Port i, in which  
i= 1, 2, …, G2, from the left pull-down list. The Port i options are identical to the Monitor by  
System function discussed above, in that users can view graphs that show All Packets, TX Packets,  
RX Packets, or Error Packets activity, but in this case, only for an individual port. The All Ports  
option is essentially a graphical display of the individual port activity that can be viewed with the  
Console Monitor function discussed above. The All Ports option shows three vertical bars for each  
port. The height of the bar represents Packets/s for the type of packet, at the instant the bar is  
being viewed. That is, as time progresses, the height of the bar moves up or down so that the user  
can view the change in the rate of packet transmission. The blue colored bar shows Unicast  
packets, the red colored bar shows Multicast packets, and the orange colored bar shows  
Broadcast packets. The graph is updated every few seconds, allowing the user to analyze data  
transmission activity in real-time.  
3-61  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
EDS-518A Series User’s Manual  
Featured Functions  
Using the MAC Address Table  
This section explains the information provided by EDS-518A’s MAC address table.  
The MAC Address table can be configured to display the following EDS-518A MAC address  
groups.  
ALL  
Select this item to show all EDS-518A MAC addresses  
ALL Learned  
ALL Static Lock  
ALL Static  
Select this item to show all EDS-518A Learned MAC addresses  
Select this item to show all EDS-518A Static Lock MAC addresses  
Select this item to show all EDS-518A Static/Static Lock /Static  
Multicast MAC addresses  
ALL Static  
Multicast  
Select this item to show all EDS-518A Static Multicast MAC  
addresses  
Port x  
Select this item to show all MAC addresses of dedicated ports  
The table will display the following information:  
MAC  
Type  
Port  
This field shows the MAC address  
This field shows the type of this MAC address  
This field shows the port that this MAC address belongs to  
Using Event Log  
3-62  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
EDS-518A Series User’s Manual  
Featured Functions  
Bootup  
Date  
This field shows how many times the EDS-518A has been rebooted or cold started.  
The date is updated based on how the current date is set in the “Basic Setting” page.  
The time is updated based on how the current time is set in the “Basic Setting” page.  
The system startup time related to this event.  
Time  
System  
Startup  
Time  
Events  
Events that have occurred.  
The following events will be record into EDS-518A’s Event Log table:  
1. Cold start  
NOTE  
2. Warm start  
3. Configuration change activated  
4. Power 1/2 transition (Off Æ On), Power 1/2 transition (On Æ Off)  
5. Authentication fail  
6. Topology changed  
7. Master setting is mismatched  
8. DI 1/2 transition (Off Æ On), DI 1/2 transition (On Æ Off)  
9. Port traffic overload  
10. dot1x Auth Fail  
11. Port link off / on  
Using HTTPS/SSL  
To secure your HTTP access, EDS-518A supports HTTPS/SSL to encrypt all HTTP traffic.  
Perform the following steps to access EDS-518A’s web browser interface via HTTPS/SSL.  
1. Open Internet Explorer and type https://EDS-518A’s IP address in the address field. Press  
Enter to establish the connection.  
2. Warning messages will pop out to warn the user that the security certificate was issued by a  
company they have not chosen to trust.  
3-63  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
EDS-518A Series User’s Manual  
Featured Functions  
3. Select Yes to enter the EDS-518A’s web browser interface and access the web browser  
interface secured via HTTPS/SSL.  
MOXA provides a Root CA certificate .After installing this certificate into your PC or  
notebook, you can access the web browser interface directly and will not see any warning  
messages again. You may download the certificate from EDS-518A’s CD-ROM.  
NOTE  
3-64  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4
Chapter  
4
EDS Configurator GUI  
EDS Configurator is a comprehensive Windows-based GUI that is used to configure and maintain  
multiple EDS-518A switches. A suite of useful utilities is available to help you locate EDS-518A  
switches attached to the same LAN as the PC host (regardless of whether or not you know the IP  
addresses of the switches), connect to an EDS-518A whose IP address is known, modify the  
network configurations of one or multiple EDS-518A switches, and update the firmware of one or  
more EDS-518A switches. EDS Configurator is designed to provide you with instantaneous  
control of all of your EDS-518A switches, regardless of location. You may download the EDS  
Configurator software from MOXA’s website free of charge.  
This chapter includes the following sections:  
Starting EDS Configurator  
Broadcast Search  
Search by IP address  
Upgrade Firmware  
Modify IP Address  
Export Configuration  
Import Configuration  
Unlock Server  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
EDS-518A Series User’s Manual  
EDS Configurator GUI  
Starting EDS Configurator  
To start EDS Configurator, locate and then run the executable file edscfgui.exe.  
NOTE  
For example, if the file was placed on the Windows desktop, it should appear as follows. Simply  
double click on the icon to run the program.  
The MOXA EtherDevice Server Configurator window will open, as shown below.  
Broadcast Search  
Use the Broadcast Search utility to search the LAN for all EDS-518A switches that are connected  
to the LAN. Note that since the search is done by MAC address, Broadcast Search will not be able  
to locate MOXA EtherDevice Servers connected outside the PC host’s LAN. Start by clicking the  
Broadcast Search icon  
, or by selecting Broadcast Search under the List Server menu.  
The Broadcast Search window will open, displaying a list of all switches located on the network,  
as well as the progress of the search.  
4-2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
EDS-518A Series User’s Manual  
EDS Configurator GUI  
Once the search is complete, the Configurator window will display a list of all switches that were  
located.  
Search by IP address  
This utility is used to search for EDS-518A switches one at a time. Note that the search is  
conducted by IP address, so you should be able to locate any EDS-518A that is properly connected  
to your LAN, WAN, or even the Internet. Start by clicking the Specify by IP address icon  
, or  
by selecting Specify IP address under the List Server menu.  
The Search Server with IP Address window will open. Enter the IP address of the switch you  
wish to search for, and then click OK.  
Once the search is complete, the Configurator window will add the switch to the list of switches.  
Upgrade Firmware  
Keep your EDS-518A up to date with the latest firmware from MOXA. Perform the following  
steps to upgrade the firmware:  
1. Download the updated firmware (*.rom) file from the MOXA website (www.moxa.com).  
2. Click the switch (from the MOXA EtherDevice Server Configurator window) whose  
firmware you wish to upgrade to highlight it.  
4-3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
EDS-518A Series User’s Manual  
EDS Configurator GUI  
3. Click the Upgrade Firmware toolbar icon , or select Upgrade under the Firmware menu.  
If the switch is Locked, you will be prompted to input the switch’s User Name and Password.  
4. Use the Open window to navigate to the folder that contains the firmware upgrade file, and  
then click the correct “*.rom” file (eds.rom in the example shown below) to select the file.  
Click Open to activate the upgrade process.  
Modify IP Address  
You may use the Modify IP Address function to reconfigure EDS-518A’s network settings. Start  
by clicking the Modify IP address icon , or by selecting Modify IP address under the  
Configuration menu.  
The Setup Configuration window will open. Checkmark the box to the left of those items that  
you wish to modify, and then Disable or Enable DHCP, and enter IP Address, Subnet mask,  
Gateway, and DNS IP. Click OK to accept the changes to the configuration.  
4-4  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
EDS-518A Series User’s Manual  
EDS Configurator GUI  
Export Configuration  
The Export Configuration utility is used to save the entire configuration of a particular  
EDS-518A to a text file. Take the following steps to export a configuration:  
1. Highlight the switch (from the Server list in the Configurator window’s left pane), and then  
click the Export toolbar icon  
or select Export Configuration from the Configuration  
menu. Use the Open window to navigate to the folder in which you want to store the  
configuration, and then type the name of the file in the File name input box. Click Open.  
2. Click OK when the Export configuration to file OK message appears.  
3. You may use a standard text editor, such as Notepad under Windows, to view and modify the  
newly created configuration file.  
4-5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
EDS-518A Series User’s Manual  
EDS Configurator GUI  
Import Configuration  
The Import Configuration function is used to import an entire configuration from a text file to  
EDS-518A. This utility can be used to transfer the configuration from one EDS-518A to another,  
by first using the Export Configuration function (described in the previous section) to save a  
switch configuration to a file, and then using the Import Configuration function. Perform the  
following steps to import a configuration:  
1. Highlight the server (from the MOXA EtherDevice Switch list in the Configurator window’s  
left pane), and then click the Import toolbar icon , or select Import Configuration from  
the Configuration menu.  
2. Use the Open window to navigate to the text file that contains the desired configuration. Once  
the file is selected, click Open to initiate the import procedure.  
3. The Setup Configuration window will be displayed, with a special note attached at the  
bottom. Parameters that have been changed will be activated with a checkmark. You may  
make more changes if necessary, and then click OK to accept the changes.  
4-6  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
EDS-518A Series User’s Manual  
EDS Configurator GUI  
4. Click Yes in response to the following warning message to accept the new settings.  
Unlock Server  
The Unlock Server function is used to open a password protected switch so that the user can  
modify its configuration, import/export a configuration, etc. There are six possible responses under  
the Status column. The Status of an EDS-518A indicates how the switch was located (by MOXA  
EtherDevice Switch Configurator), and what type of password protection it has.  
The six options are as follows (note that the term Fixed is borrowed from the standard fixed IP  
address networking terminology):  
y
Locked  
The switch is password protected, “Broadcast Search” was used to locate it, and the password  
has not yet been entered from within the current Configurator session.  
y
Unlocked  
The switch is password protected, “Broadcast Search” was used to locate it, and the password  
has been entered from within the current Configurator session. Henceforth during this  
Configurator session, activating various utilities for this switch will not require re-entering the  
server password.  
y
y
y
Blank  
EDS-518A is not password protected, and “Broadcast Search” was used to locate it.  
Fixed  
EDS-518A is not password protected, and “Search by IP address” was used to locate it manually.  
Locked Fixed  
EDS-518A is password protected, “Search by IP address” was used to locate it manually, and the  
password has not yet been entered from within the current Configurator session.  
y
Unlocked Fixed  
EDS-518A is password protected, “Search by IP address” was used to locate it manually, and  
the password has been entered from within the current Configurator session. Henceforth  
during this Configurator session, activating various utilities for this EDS-518A will not  
require re-entering the server password.  
Follow the steps given below to unlock a locked EDS-518A (i.e., an EDS-518A with Status  
“Locked” or “Locked Fixed”). Highlight the server (from the MOXA EtherDevice Switch list in  
the Configurator window’s left pane), and then click the Unlock toolbar icon , or select Unlock  
from the Configuration menu.  
1. Enter the switch’s User Name and Password when prompted, and then click OK.  
4-7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
EDS-518A Series User’s Manual  
EDS Configurator GUI  
2. When the Unlock status window reports Progress as OK, click the Close button in the upper  
right corner of the window.  
3. The status of the switch will now read either Unlocked or Unlocked Fixed.  
4-8  
Download from Www.Somanuals.com. All Manuals Search And Download.  
A
Appendix  
A
MIB Groups  
MOXA EDS-518A comes with built-in SNMP (Simple Network Management Protocol) agent  
software that supports cold/warm start trap, line up/down trap, and RFC 1213 MIB-II.  
The standard MIB groups that MOXA EDS-518A series support are:  
MIB II.1 – System Group  
sysORTable  
MIB II.2 – Interfaces Group  
ifTable  
MIB II.4 – IP Group  
ipAddrTable  
ipNetToMediaTable  
IpGroup  
IpBasicStatsGroup  
IpStatsGroup  
MIB II.5 – ICMP Group  
IcmpGroup  
IcmpInputStatus  
IcmpOutputStats  
MIB II.6 – TCP Group  
tcpConnTable  
TcpGroup  
TcpStats  
MIB II.7 – UDP Group  
udpTable  
UdpStats  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
EDS-518A Series User’s Manual  
MIB Groups  
MIB II.10 – Transmission Group  
dot3  
dot3StatsTable  
MIB II.11 – SNMP Group  
SnmpBasicGroup  
SnmpInputStats  
SnmpOutputStats  
MIB II.17 – dot1dBridge Group  
dot1dBase  
dot1dBasePortTable  
dot1dStp  
dot1dStpPortTable  
dot1dTp  
dot1dTpFdbTable  
dot1dTpPortTable  
dot1dTpHCPortTable  
dot1dTpPortOverflowTable  
pBridgeMIB  
dot1dExtBase  
dot1dPriority  
dot1dGarp  
qBridgeMIB  
dot1qBase  
dot1qTp  
dot1qFdbTable  
dot1qTpPortTable  
dot1qTpGroupTable  
dot1qForwardUnregisteredTable  
dot1qStatic  
dot1qStaticUnicastTable  
dot1qStaticMulticastTable  
dot1qVlan  
dot1qVlanCurrentTable  
dot1qVlanStaticTable  
dot1qPortVlanTable  
A-2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
EDS-518A Series User’s Manual  
MIB Groups  
EDS-518A also provides a private MIB file, located in the file “MOXA-EDS518A-MIB.my” on  
the EDS-518A Series utility CD-ROM.  
Public Traps:  
1. Cold Start  
2. Link Up  
3. Link Down  
4. Authentication Failure  
5. dot1dBridge New Root  
6. dot1dBridge Topology Changed  
Private Traps:  
1. Configuration Changed  
2. Power On  
3. Power Off  
4. Traffic Overloaded  
5. Turbo Ring Topology Changed  
6. Turbo Ring Coupling Port Changed  
7. Turbo Ring Master Mismatch  
A-3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
B
Appendix  
B
Specifications  
Technology  
Standards  
IEEE802.3, 802.3u, 802.3x, 802.1D, 802.1w,  
802.1Q, 802.1p  
Protocols  
MIB  
IGMP V1/V2/V3 device, GVRP, SNMP V1/V2c/V3,  
DHCP Server/Client, BOOTP, TFTP, SNTP, SMTP,  
RARP and EDS-SNMP OPC server Pro (Optional)  
MIB-II, Ethernet-Like MIB, P-BRIDGE MIB,  
Q-BRIDGE MIB, Bridge MIB, RSTP MIB, RMON  
MIB Group 1,2.3,9  
Interface  
RJ45 Ports  
10/100/1000BaseT(X) auto negotiation speed, F/H  
duplex mode, and auto MDI/MDI-X connection  
Fiber Ports  
100BaseFX (SC/ST connector) and optional  
1000BaseSX/LX/LHX/ZX (LC connector)  
Console  
RS-232 (RJ45)  
LED Indicators  
PWR1, PWR2, FAULT, 10/100M (TP port), 100M  
(Fiber port), 1000M, Ring Master and Ring Coupler  
Alarm Contact  
Digital Input  
Two relay outputs with current carrying capacity of  
1A @ 24 VDC  
Two inputs with the same ground, but electrically  
isolated from the electronics  
• For state “1”: +13 to +30V  
• For state “0”: -30 to +3V  
• Max. input current: 8 mA  
Optical Fiber  
100BaseFX  
Distance:  
Multi mode:  
0 to 5 km, 1300 nm (50/125 μm, 800 MHz*km)  
0 to 4 km, 1300 nm (62.5/125 μm, 500 MHz*km)  
0 to 40 km, 1310 nm (9/125 μm, 3.5 PS/(nm*km))  
0 to 80 km, 1550 nm (9/125 μm, 19 PS/(nm*km))  
Single mode:  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
EDS-518A Series User’s Manual  
Specifications  
Min. TX Output:  
Multi mode :  
-20 dBm  
Single mode:  
0 to 40 km, -5 dBm  
0 to 80 km, -5 dBm  
Max. TX Output:  
Multi mode :  
-14 dBm  
Single mode:  
0 to 40 km, 0 dBm  
0 to 80 km, 0 dBm  
Sensitivity:  
Multi mode :  
Single mode:  
-34 to -30 dBm  
-36 to -32 dBm  
1000BaseSX/LX/LHX/ZX  
Distance:  
Multi mode:  
0 to 500m, 850 nm (50/125 µm, 400 MHz*km)  
0 to 275m, 850 nm (62.5/125 µm, 200 MHz*km)  
0 to 1100m, 1310 nm (50/125 µm, 800 MHz*km)  
1000BaseSX  
1000BaseLX  
0 to 550m, 1310 nm (62.5.125 µm, 500 MHz*km)  
Single mode:  
0 to 10 km, 1310 nm (9/125 µm, 3.5 PS/(nm*km))  
1000BaseLX  
1000BaseLHX  
1000BaseZX  
0 to 40 km, 1310 nm ((9/125 µm, 3.5 PS/(nm*km)))  
0 to 80 km, 1550 nm ((9/125 µm, 19 PS/(nm*km))  
Power  
Input Voltage  
Input Current (@24V)  
24 VDC(12 to 45 VDC), redundant inputs  
0.67A: (EDS-518A)  
0.78A: (EDS-518A-MM-SC/ST, EDS-518A-SS-SC)  
Two removable 6-pin terminal blocks  
Present  
Connection  
Overload Current  
Protection  
Reverse Polarity ProtectionPresent  
Mechanical  
Casing  
IP30 protection, metal case  
Dimensions  
Weight  
95 x 135 x 140 mm (W x H x D)  
1.63 kg  
Installation  
DIN-Rail, Wall Mounting (optional kit)  
B-2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
EDS-518A Series User’s Manual  
Specifications  
Environmental  
Operating Temperature  
Storage Temperature  
0 to 60°C (32 to 140°F)  
-40 to 85°C (-40 to 185°F)  
Ambient Relative  
Humidity  
5% to 95% (non-condensing)  
Regulatory Approvals  
Safety  
UL60950, UL 508(Pending), CSA C22.2 No. 60950,  
EN60950  
Hazardous Location  
UL/cUL Class I, Division 2, Groups A, B, C,  
and D, ATEX Class I, Zone 2, EEx nC IIC (Pending)  
EMI  
FCC Part 15, CISPR (EN55022) class A  
EMS  
EN61000-4-2 (ESD), Level 3  
EN61000-4-3 (RS), Level 3  
EN61000-4-4 (EFT), Level 3  
EN61000-4-5 (Surge), Level 3  
EN61000-4-6 (CS), Level 3  
EN61000-4-8  
EN61000-4-11  
EN61000-4-12  
Shock  
IEC60068-2-27  
IEC60068-2-32  
IEC60068-2-6  
5 years  
Freefall  
Vibration  
WARRANTY  
B-3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
C
Appendix  
C
Service Information  
This appendix shows you how to contact MOXA for information about this and other products,  
and how to report problems.  
In this appendix, we cover the following topics.  
MOXA Internet Services  
Problem Report Form  
Product Return Procedure  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
EDS-518A Series User’s Manual  
Service Information  
MOXA Internet Services  
Customer satisfaction is our primary concern. To ensure that customers receive the full benefit of  
our products, MOXA Internet Services has been set up to provide technical support, driver updates,  
product information, and user’s manual updates.  
The following services are provided  
E-mail for technical support................................support@moxanet.com (Worldwide)  
...............................support@moxa.com  
(The Americas)  
World Wide Web (WWW) Site for product information:  
...............................http://www.moxa.com  
C-2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
EDS-518A Series User’s Manual  
Service Information  
Problem Report Form  
MOXA EDS-518A Series  
Customer name:  
Company:  
Tel:  
Fax:  
Email:  
Date:  
Serial Number: _________________  
Problem Description: Please describe the symptoms of the problem as clearly as possible, including any error  
messages you see. A clearly written description of the problem will allow us to reproduce the symptoms, and  
expedite the repair of your product.  
C-3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
EDS-518A Series User’s Manual  
Service Information  
Product Return Procedure  
For product repair, exchange, or refund, the customer must:  



Provide evidence of original purchase.  
Obtain a Product Return Agreement (PRA) from the sales representative or dealer.  
Fill out the Problem Report Form (PRF). Include as much detail as possible for a shorter  
product repair time.  

Carefully pack the product in an anti-static package, and send it, pre-paid, to the dealer. The  
PRA should be visible on the outside of the package, and include a description of the problem,  
along with the return address and telephone number of a technical contact.  
C-4  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 

Miele Ventilation Hood DA3060 User Manual
Millennium Enterprises Air Conditioner Z33 User Manual
Multiquip Automobile Parts MT 86D User Manual
Multiquip Chainsaw PS403016 User Manual
Napoleon Grills Gas Grill PT750RSB User Manual
National Instruments Computer Hardware NI 5401 User Manual
Navman GPS Receiver iCN 620 User Manual
Old Town Canoe Co Marine Instruments E1569 User Manual
Panasonic Impact Driver EYFLA4A User Manual
Panasonic TV Cables et adser User Manual