MIG (GMAW) Welding  
Description  
Wire Feeder And Feeder Gun  
XR A And XR W  
File: MIG (GMAW)  
Visit our website at  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TABLE OF CONTENTS  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TABLE OF CONTENTS  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SECTION 1 SAFETY PRECAUTIONS - READ BEFORE USING  
som _3/05  
Y
Warning: Protect yourself and others from injury — read and follow these precautions.  
1-1. Symbol Usage  
Means Warning! Watch Out! There are possible hazards  
with this procedure! The possible hazards are shown in  
the adjoining symbols.  
This group of symbols means Warning! Watch Out! possible  
ELECTRIC SHOCK, MOVING PARTS, and HOT PARTS hazards.  
Consult symbols and related instructions below for necessary actions  
to avoid the hazards.  
Y
Marks a special safety message.  
. Means “Note”; not safety related.  
1-2. Arc Welding Hazards  
Y
The symbols shown below are used throughout this manual to  
call attention to and identify possible hazards. When you see  
the symbol, watch out, and follow the related instructions to  
avoid the hazard. The safety information given below is only  
a summary of the more complete safety information found in  
the Safety Standards listed in Section 1-5. Read and follow all  
Safety Standards.  
D
D
D
D
Turn off all equipment when not in use.  
Do not use worn, damaged, undersized, or poorly spliced cables.  
Do not drape cables over your body.  
If earth grounding of the workpiece is required, ground it directly  
with a separate cable.  
Do not touch electrode if you are in contact with the work, ground,  
or another electrode from a different machine.  
D
D
Y
Y
Only qualified persons should install, operate, maintain, and  
repair this unit.  
Do not touch electrode holders connected to two welding ma-  
chines at the same time since double open-circuit voltage will be  
present.  
During operation, keep everybody, especially children, away.  
D
Use only well-maintained equipment. Repair or replace damaged  
parts at once. Maintain unit according to manual.  
ELECTRIC SHOCK can kill.  
D
D
D
Wear a safety harness if working above floor level.  
Keep all panels and covers securely in place.  
Clamp work cable with good metal-to-metal contact to workpiece  
or worktable as near the weld as practical.  
Insulate work clamp when not connected to workpiece to prevent  
contact with any metal object.  
Do not connect more than one electrode or work cable to any  
single weld output terminal.  
Touching live electrical parts can cause fatal shocks  
or severe burns. The electrode and work circuit is  
electrically live whenever the output is on. The input  
power circuit and machine internal circuits are also  
live when power is on. In semiautomatic or automatic wire welding, the  
wire, wire reel, drive roll housing, and all metal parts touching the  
welding wire are electrically live. Incorrectly installed or improperly  
groundedequipment is a hazard.  
D
D
D
D
D
Do not touch live electrical parts.  
Wear dry, hole-free insulating gloves and body protection.  
Insulate yourself from work and ground using dry insulating mats  
or covers big enough to prevent any physical contact with the work  
or ground.  
Do not use AC output in damp areas, if movement is confined, or if  
there is a danger of falling.  
Use AC output ONLY if required for the welding process.  
If AC output is required, use remote output control if present on  
unit.  
SIGNIFICANT DC VOLTAGE exists in inverter-type  
welding power sources after removal of input  
power.  
D
Turn Off inverter, disconnect input power, and discharge input  
capacitors according to instructions in Maintenance Section  
before touching any parts.  
D
D
D
FUMES AND GASES can be hazardous.  
D
Additionalsafety precautions are required when any of the follow-  
ing electrically hazardous conditions are present: in damp  
locations or while wearing wet clothing; on metal structures such  
as floors, gratings, or scaffolds; when in cramped positions such  
as sitting, kneeling, or lying; or when there is a high risk of unavoid-  
able or accidental contact with the workpiece or ground. For these  
conditions, use the following equipment in order presented: 1) a  
semiautomaticDC constant voltage (wire) welder, 2) a DC manual  
(stick) welder, or 3) an AC welder with reduced open-circuit volt-  
age. In most situations, use of a DC, constant voltage wire welder  
is recommended. And, do not work alone!  
Welding produces fumes and gases. Breathing  
these fumes and gases can be hazardous to your  
health.  
D
D
Keep your head out of the fumes. Do not breathe the fumes.  
If inside, ventilate the area and/or use local forced ventilation at the  
arc to remove welding fumes and gases.  
D
D
If ventilation is poor, wear an approved air-supplied respirator.  
Read and understand the Material Safety Data Sheets (MSDSs)  
and the manufacturer’s instructions for metals, consumables,  
coatings, cleaners, and degreasers.  
Work in a confined space only if it is well ventilated, or while  
wearing an air-supplied respirator. Always have a trained watch-  
person nearby. Welding fumes and gases can displace air and  
lower the oxygen level causing injury or death. Be sure the breath-  
ing air is safe.  
Do not weld in locations near degreasing, cleaning, or spraying op-  
erations. The heat and rays of the arc can react with vapors to form  
highly toxic and irritating gases.  
Do not weld on coated metals, such as galvanized, lead, or  
cadmiumplated steel, unless the coating is removed from the weld  
area, the area is well ventilated, and while wearing an air-supplied  
respirator. The coatings and any metals containing these elements  
can give off toxic fumes if welded.  
D
Disconnect input power or stop engine before installing or  
servicing this equipment. Lockout/tagout input power according to  
OSHA 29 CFR 1910.147 (see Safety Standards).  
D
D
D
Properly install and ground this equipment according to its  
Owner’s Manual and national, state, and local codes.  
Always verify the supply ground check and be sure that input  
power cord ground wire is properly connected to ground terminal in  
disconnect box or that cord plug is connected to a properly  
groundedreceptacle outlet.  
D
D
D
D
When making input connections, attach proper grounding conduc-  
tor first double-check connections.  
Frequently inspect input power cord for damage or bare wiring −  
replace cord immediately if damaged bare wiring can kill.  
OM-1581 Page 1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
ARC RAYS can burn eyes and skin.  
BUILDUP OF GAS can injure or kill.  
D
D
Shut off shielding gas supply when not in use.  
Always ventilate confined spaces or use  
approved air-supplied respirator.  
Arc rays from the welding process produce intense  
visible and invisible (ultraviolet and infrared) rays  
that can burn eyes and skin. Sparks fly off from the  
weld.  
D
Wear an approved welding helmet fitted with a proper shade of fil-  
ter lenses to protect your face and eyes when welding or watching  
(see ANSI Z49.1 and Z87.1 listed in Safety Standards).  
HOT PARTS can cause severe burns.  
D
D
D
Wear approved safety glasses with side shields under your  
helmet.  
D
D
Do not touch hot parts bare handed.  
Allow cooling period before working on gun or  
torch.  
To handle hot parts, use proper tools and/or  
wear heavy, insulated welding gloves and  
clothing to prevent burns.  
Use protective screens or barriers to protect others from flash,  
glare and sparks; warn others not to watch the arc.  
D
Wear protective clothing made from durable, flame-resistant mate-  
rial (leather, heavy cotton, or wool) and foot protection.  
WELDING can cause fire or explosion.  
MAGNETIC FIELDS can affect pacemakers.  
Welding on closed containers, such as tanks,  
drums, or pipes, can cause them to blow up. Sparks  
can fly off from the welding arc. The flying sparks, hot  
workpiece, and hot equipment can cause fires and  
D
D
Pacemaker wearers keep away.  
Wearers should consult their doctor before  
going near arc welding, gouging, or spot  
welding operations.  
burns. Accidental contact of electrode to metal objects can cause  
sparks, explosion, overheating, or fire. Check and be sure the area is  
safe before doing any welding.  
D
Remove all flammables within 35 ft (10.7 m) of the welding arc. If  
this is not possible, tightly cover them with approved covers.  
NOISE can damage hearing.  
D
D
D
Do not weld where flying sparks can strike flammable material.  
Protect yourself and others from flying sparks and hot metal.  
Noise from some processes or equipment can  
damagehearing.  
Be alert that welding sparks and hot materials from welding can  
easily go through small cracks and openings to adjacent areas.  
D
Wear approved ear protection if noise level is  
high.  
D
D
Watch for fire, and keep a fire extinguisher nearby.  
Be aware that welding on a ceiling, floor, bulkhead, or partition can  
cause fire on the hidden side.  
CYLINDERS can explode if damaged.  
D
D
Do not weld on closed containers such as tanks, drums, or pipes,  
unless they are properly prepared according to AWS F4.1 (see  
Safety Standards).  
Shielding gas cylinders contain gas under high  
pressure. If damaged, a cylinder can explode. Since  
gas cylinders are normally part of the welding  
process, be sure to treat them carefully.  
Connect work cable to the work as close to the welding area as  
practical to prevent welding current from traveling long, possibly  
unknown paths and causing electric shock, sparks, and fire  
hazards.  
D
D
Protect compressed gas cylinders from excessive heat, mechani-  
cal shocks, physical damage, slag, open flames, sparks, and arcs.  
D
D
Do not use welder to thaw frozen pipes.  
Install cylinders in an upright position by securing to a stationary  
support or cylinder rack to prevent falling or tipping.  
Remove stick electrode from holder or cut off welding wire at  
contact tip when not in use.  
D
D
D
D
D
Keep cylinders away from any welding or other electrical circuits.  
Never drape a welding torch over a gas cylinder.  
D
D
D
Wear oil-free protective garments such as leather gloves, heavy  
shirt, cuffless trousers, high shoes, and a cap.  
Never allow a welding electrode to touch any cylinder.  
Never weld on a pressurized cylinder explosion will result.  
Remove any combustibles, such as a butane lighter or matches,  
from your person before doing any welding.  
Use only correct shielding gas cylinders, regulators, hoses, and fit-  
tings designed for the specific application; maintain them and  
associated parts in good condition.  
Follow requirements in OSHA 1910.252 (a) (2) (iv) and NFPA 51B  
for hot work and have a fire watcher and extinguisher nearby.  
D
D
Turn face away from valve outlet when opening cylinder valve.  
Keep protective cap in place over valve except when cylinder is in  
use or connected for use.  
FLYING METAL can injure eyes.  
D
Welding, chipping, wire brushing, and grinding  
cause sparks and flying metal. As welds cool,  
they can throw off slag.  
Wear approved safety glasses with side  
shields even under your welding helmet.  
D
D
Use the right equipment, correct procedures, and sufficient num-  
ber of persons to lift and move cylinders.  
Read and follow instructions on compressed gas cylinders,  
associated equipment, and Compressed Gas Association (CGA)  
publication P-1 listed in Safety Standards.  
D
OM-1581 Page 2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1-3. Additional Symbols For Installation, Operation, And Maintenance  
FIRE OR EXPLOSION hazard.  
MOVING PARTS can cause injury.  
D
Do not install or place unit on, over, or near  
combustiblesurfaces.  
Do not install unit near flammables.  
D
D
Keep away from moving parts such as fans.  
Keep all doors, panels, covers, and guards  
closed and securely in place.  
D
D
D
Have only qualified persons remove doors,  
panels, covers, or guards for maintenance as  
necessary.  
Reinstall doors, panels, covers, or guards  
when maintenance is finished and before re-  
connecting input power.  
D
Do not overload building wiring be sure power supply system is  
properly sized, rated, and protected to handle this unit.  
FALLING UNIT can cause injury.  
D
D
D
Use lifting eye to lift unit only, NOT running  
gear, gas cylinders, or any other accessories.  
Use equipment of adequate capacity to lift and  
support unit.  
If using lift forks to move unit, be sure forks are  
long enough to extend beyond opposite side of  
unit.  
READ INSTRUCTIONS.  
D
Read Owner’s Manual before using or servic-  
ing unit.  
D
Use only genuine Miller/Hobart replacement  
parts.  
H.F. RADIATION can cause interference.  
D
High-frequency (H.F.) can interfere with radio  
navigation, safety services, computers, and  
communicationsequipment.  
Have only qualified persons familiar with  
electronic equipment perform this installation.  
OVERUSE can cause OVERHEATING  
D
D
Allow cooling period; follow rated duty cycle.  
Reduce current or reduce duty cycle before  
starting to weld again.  
D
D
Do not block or filter airflow to unit.  
D
D
The user is responsible for having a qualified electrician prompt-  
ly correct any interference problem resulting from the installa-  
tion.  
If notified by the FCC about interference, stop using the  
equipmentat once.  
STATIC (ESD) can damage PC boards.  
D
D
Have the installation regularly checked and maintained.  
D
Put on grounded wrist strap BEFORE handling  
boards or parts.  
Use proper static-proof bags and boxes to  
store, move, or ship PC boards.  
Keep high-frequency source doors and panels tightly shut, keep  
spark gaps at correct setting, and use grounding and shielding to  
minimize the possibility of interference.  
D
ARC WELDING can cause interference.  
MOVING PARTS can cause injury.  
D
Electromagnetic energy can interfere with  
sensitive electronic equipment such as  
computers and computer-driven equipment  
such as robots.  
Be sure all equipment in the welding area is  
electromagneticallycompatible.  
D
D
Keep away from moving parts.  
Keep away from pinch points such as drive  
rolls.  
D
D
D
D
D
To reduce possible interference, keep weld cables as short as  
possible, close together, and down low, such as on the floor.  
Locate welding operation 100 meters from any sensitive elec-  
tronic equipment.  
WELDING WIRE can cause injury.  
D
Do not press gun trigger until instructed to do  
so.  
Be sure this welding machine is installed and grounded  
according to this manual.  
D
Do not point gun toward any part of the body,  
other people, or any metal when threading  
welding wire.  
If interference still occurs, the user must take extra measures  
such as moving the welding machine, using shielded cables,  
using line filters, or shielding the work area.  
1-4. California Proposition 65 Warnings  
Y
Welding or cutting equipment produces fumes or gases which  
contain chemicals known to the State of California to cause  
birth defects and, in some cases, cancer. (California Health &  
Safety Code Section 25249.5 et seq.)  
For Gasoline Engines:  
Y
Engine exhaust contains chemicals known to the State of  
California to cause cancer, birth defects, or other reproductive  
harm.  
For Diesel Engines:  
Y
Battery posts, terminals and related accessories contain lead  
and lead compounds, chemicals known to the State of  
California to cause cancer and birth defects or other  
reproductiveharm. Wash hands after handling.  
Y
Diesel engine exhaust and some of its constituents are known  
to the State of California to cause cancer, birth defects, and  
other reproductive harm.  
OM-1581 Page 3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
1-5. Principal Safety Standards  
Safety inWelding, Cutting, and Allied Processes, ANSI Standard Z49.1,  
from Global Engineering Documents (phone: 1-877-413-5184, website:  
www.global.ihs.com).  
Boulevard, Rexdale, Ontario, Canada M9W 1R3 (phone:  
8004636727 or in Toronto 4167474044, website: www.csain-  
ternational.org).  
Practice For Occupational And Educational Eye And Face Protection,  
ANSI Standard Z87.1, from American National Standards Institute, 11  
West 42nd Street, New York, NY 100368002 (phone: 2126424900,  
website: www.ansi.org).  
Recommended Safe Practices for the Preparation for Weldingand Cut-  
ting of Containers and Piping, American Welding Society Standard  
AWS F4.1 from Global Engineering Documents (phone:  
1-877-413-5184,website: www.global.ihs.com).  
Standard for Fire Prevention During Welding, Cutting, and Other Hot  
Work, NFPA Standard 51B, from National Fire Protection Association,  
P.O. Box 9101, 1 Battery March Park, Quincy, MA 022699101 (phone:  
6177703000,website: www.nfpa.org).  
NationalElectrical Code, NFPA Standard 70, from National Fire Protec-  
tion Association, P.O. Box 9101, 1 Battery March Park, Quincy, MA  
022699101(phone: 6177703000, website: www.nfpa.org).  
Safe Handling of Compressed Gases in Cylinders, CGA Pamphlet P-1,  
from Compressed Gas Association, 1735 Jefferson Davis Highway,  
Suite 1004, Arlington, VA 222024102 (phone: 7034120900, web-  
site: www.cganet.com).  
OSHA, Occupational Safety and Health Standards for General Indus-  
try, Title 29, Code of Federal Regulations (CFR), Part 1910, Subpart Q,  
and Part 1926, Subpart J, from U.S. Government Printing Office, Super-  
intendent of Documents, P.O. Box 371954, Pittsburgh, PA 15250 (there  
are 10 Regional Offices−−phone for Region 5, Chicago, is  
3123532220,website: www.osha.gov).  
Code for Safety in Welding and Cutting, CSA Standard W117.2, from  
Canadian Standards Association, Standards Sales, 178 Rexdale  
1-6. EMF Information  
Considerations About Welding And The Effects Of Low Frequency  
Electric And Magnetic Fields  
1. Keep cables close together by twisting or taping them.  
2. Arrange cables to one side and away from the operator.  
3. Do not coil or drape cables around your body.  
Welding current, as it flows through welding cables, will cause electro-  
magnetic fields. There has been and still is some concern about such  
fields. However, after examining more than 500 studies spanning 17  
years of research, a special blue ribbon committee of the National  
Research Council concluded that: “The body of evidence, in the  
committees judgment, has not demonstrated that exposure to power-  
frequency electric and magnetic fields is a human-health hazard.”  
However, studies are still going forth and evidence continues to be  
examined.Until the final conclusions of the research are reached, you  
may wish to minimize your exposure to electromagnetic fields when  
welding or cutting.  
4. Keep welding power source and cables as far away from opera-  
tor as practical.  
5. Connect work clamp to workpiece as close to the weld as possi-  
ble.  
About Pacemakers:  
Pacemaker wearers consult your doctor before welding or going near  
welding operations. If cleared by your doctor, then following the above  
procedures is recommended.  
To reduce magnetic fields in the workplace, use the following  
procedures:  
OM-1581 Page 4  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
SECTION 2 CONSIGNES DE SÉCURITÉ LIRE AVANT UTILISATION  
som _3/05  
Y
Avertissement: se protéger et protéger les autres contre le risque de blessure — lire et respecter ces consignes.  
2-1. Symboles utilisés  
Symbole graphique d’avertissement ! Attention ! Cette pro-  
cédure comporte des risques possibles ! Les dangers éven-  
tuels sont représentés par les symboles graphiques joints.  
Ce groupe de symboles signifie Avertissement ! Attention ! Risques  
d’ÉLECTROCUTION, ORGANES MOBILES et PARTIES  
CHAUDES. Consulter les symboles et les instructions afférentes  
ci-dessous concernant les mesures à prendre pour supprimer  
les dangers.  
Y
Indique un message de sécurité particulier  
. Signifie NOTE ; n’est pas relatif à la sécurité.  
2-2. Dangers relatifs au soudage à l’arc  
Y
Les symboles représentés ci-dessous sont utilisés dans ce manuel  
pour attirer l’attention et identifier les dangers possibles. En  
présence de l’un de ces symboles, prendre garde et suivre les  
instructions afférentes pour éviter tout risque. Les instructions en  
matière de sécurité indiquées ci-dessous ne constituent qu’un  
sommaire des instructions de sécurité plus complètes fournies  
dans les normes de sécurité énumérées dans la Section 2-5. Lire et  
observer toutes les normes de sécurité.  
Seul un personnel qualifié est autorisé à installer, faire fonction-  
ner, entretenir et réparer cet appareil.  
Pendant le fonctionnement, maintenir à distance toutes les per-  
sonnes, notamment les enfants de l’appareil.  
D
Vérifier fréquemment le cordon d’alimentation afin de s’assurer qu’il  
n’est pas altéré ou à nu, le remplacer immédiatement s’il l’est. Un fil à nu  
peut entraîner la mort.  
L’équipement doit être hors tension lorsqu’il n’est pas utilisé.  
Ne pas utiliser des câbles usés, endommagés, de grosseur insuffisante  
ou mal épissés.  
Ne pas enrouler les câbles autour du corps.  
Si la pièce soudée doit être mise à la terre, le faire directement avec un  
câble distinct.  
Ne pas toucher l’électrode quand on est en contact avec la pièce, la terre  
ou une électrode provenant d’une autre machine.  
Ne pas toucher des porte électrodes connectés à deux machines en  
même temps à cause de la présence d’une tension à vide doublée.  
N’utiliser qu’un matériel en bon état. Réparer ou remplacer sur-le-  
champ les pièces endommagées. Entretenir l’appareil conformément à  
ce manuel.  
Porter un harnais de sécurité si l’on doit travailler au-dessus du sol.  
S’assurer que tous les panneaux et couvercles sont correctement en  
place.  
Fixer le câble de retour de façon à obtenir un bon contact métal-métal  
avec la pièce à souder ou la table de travail, le plus près possible de la  
soudure.  
Isoler la pince de masse quand pas mis à la pièce pour éviter le contact  
avec tout objet métallique.  
D
D
D
D
Y
Y
D
D
D
UNE DÉCHARGE ÉLECTRIQUE peut  
entraîner la mort.  
Le contact d’organes électriques sous tension peut  
provoquer des accidents mortels ou des brûlures  
graves. Le circuit de l’électrode et de la pièce est  
sous tension lorsque le courant est délivré à la  
D
D
D
sortie. Le circuit d’alimentation et les circuits internes de la machine  
sont également sous tension lorsque l’alimentation est sur Marche.  
Dans le mode de soudage avec du fil, le fil, le dérouleur, le bloc de  
commande du rouleau et toutes les parties métalliques en contact  
avec le fil sont sous tension électrique. Un équipement installé ou mis  
à la terre de manière incorrecte ou impropre constitue un danger.  
D
D
Ne pas raccorder plus d’une électrode ou plus d’un câble de masse à  
une même borne de sortie de soudage.  
D
D
Ne pas toucher aux pièces électriques sous tension.  
Porter des gants isolants et des vêtements de protection secs et sans  
trous.  
S’isoler de la pièce à couper et du sol en utilisant des housses ou des  
tapis assez grands afin d’éviter tout contact physique avec la pièce à  
couper ou le sol.  
Ne pas se servir de source électrique à courant électrique dans les zo-  
nes humides, dans les endroits confinés ou là où on risque de tomber.  
Se servir d’une source électrique à courant électrique UNIQUEMENT si  
le procédé de soudage le demande.  
Si l’utilisation d’une source électrique à courant électrique s’avère né-  
cessaire, se servir de la fonction de télécommande si l’appareil en est  
équipé.  
Il reste une TENSION DC NON NÉGLIGEABLE dans  
les sources de soudage onduleur quand on a coupé  
l’alimentation.  
D
D
Arrêter les convertisseurs, débrancher le courant électrique et  
décharger les condensateurs d’alimentation selon les instructions indi-  
quées dans la partie Entretien avant de toucher les pièces.  
D
D
D
LES FUMÉES ET LES GAZ peuvent  
être dangereux.  
Le soudage génère des fumées et des gaz. Leur  
inhalationpeut être dangereuse pour la santé.  
D
D’autres consignes de sécurité sont nécessaires dans les conditions  
suivantes : risques électriques dans un environnement humide ou si l’on  
porte des vêtements mouillés ; sur des structures métalliques telles que  
sols, grilles ou échafaudages ; en position coincée comme assise, à ge-  
noux ou couchée ; ou s’il y a un risque élevé de contact inévitable ou  
accidentel avec la pièce à souder ou le sol. Dans ces conditions, utiliser  
les équipements suivants, dans l’ordre indiqué : 1) un poste à souder DC  
à tension constante (à fil), 2) un poste à souder DC manuel (électrode)  
ou 3) un poste à souder AC à tension à vide réduite. Dans la plupart des  
situations, l’utilisation d’un poste à souder DC à fil à tension constante  
est recommandée. En outre, ne pas travailler seul !  
Couper l’alimentation ou arrêter le moteur avant de procéder  
à l’installation, à la réparation ou à l’entretien de l’appareil. Déverrouiller  
l’alimentation selon la norme OSHA 29 CFR 1910.147 (voir normes de  
sécurité).  
Installer le poste correctement et le mettre à la terre convenablement  
selon les consignes du manuel de l’opérateur et les normes nationales,  
provinciales et locales.  
D
D
D
D
Ne pas mettre sa tête au-dessus des vapeurs. Ne pas respirer ces va-  
peurs.  
À l’intérieur, ventiler la zone et/ou utiliser une ventilation forcée au niveau de  
l’arc pour l’évacuation des fumées et des gaz de soudage.  
Si la ventilation est médiocre, porter un respirateur anti-vapeurs approu-  
vé.  
Lire et comprendre les spécifications de sécurité des matériaux (MSDS) et  
les instructions du fabricant concernant les métaux, les consommables, les  
revêtements, les nettoyants et les dégraisseurs.  
Travailler dans un espace fermé seulement s’il est bien ventilé ou en  
portant un respirateur à alimentation d’air. Demander toujours à un sur-  
veillant dûment formé de se tenir à proximité. Des fumées et des gaz de  
soudage peuvent déplacer l’air et abaisser le niveau d’oxygène provo-  
quant des blessures ou des accidents mortels. S’assurer que l’air de  
respiration ne présente aucun danger.  
Ne pas souder dans des endroits situés à proximité d’opérations de dé-  
graissage, de nettoyage ou de pulvérisation. La chaleur et les rayons de  
l’arc peuvent réagir en présence de vapeurs et former des gaz haute-  
ment toxiques et irritants.  
Ne pas souder des métaux munis d’un revêtement, tels que l’acier gal-  
vanisé, plaqué en plomb ou au cadmium à moins que le revêtement n’ait  
été enlevé dans la zone de soudure, que l’endroit soit bien ventilé et en  
portant un respirateur à alimentation d’air. Les revêtements et tous les  
métaux renfermant ces éléments peuvent dégager des fumées toxi-  
ques en cas de soudage.  
D
D
D
D
D
D
Toujours vérifier la terre du cordon d’alimentation. Vérifier et s’assurer  
que le fil de terre du cordon d’alimentation est bien raccordé à la borne  
de terre du sectionneur ou que la fiche du cordon est raccordée à une  
prise correctement mise à la terre.  
En effectuant les raccordements d’entrée, fixer d’abord le conducteur  
de mise à la terre approprié et contre-vérifier les connexions.  
D
OM-1581 Page 5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
LES RAYONS D’ARC peuvent entraî-  
ner des brûlures aux yeux et à la peau.  
LES ACCUMULATIONS DE GAZ  
risquent de provoquer des blessures  
ou même la mort.  
Le rayonnement de l’arc du procédé de soudage  
génère des rayons visibles et invisibles intenses  
(ultraviolets et infrarouges) susceptibles de provo-  
quer des brûlures dans les yeux et sur la peau.  
D
Fermer l’alimentation du gaz protecteur en cas  
de non-utilisation.  
D
Veiller toujours à bien aérer les espaces confi-  
nés ou se servir d’un respirateur d’adduction  
d’air homologué.  
Des étincelles sont projetées pendant le soudage.  
D
Porter un casque de soudage approuvé muni de verres filtrants ap-  
proprié pour protéger visage et yeux pendant le soudage (voir ANSI  
Z49.1 et Z87.1 énuméré dans les normes de sécurité).  
D
D
Porter des lunettes de sécurité avec écrans latéraux même sous vo-  
DES PIÈCES CHAUDES peuvent  
provoquer des brûlures graves.  
tre casque.  
Avoir recours à des écrans protecteurs ou à des rideaux pour  
protéger les autres contre les rayonnements les éblouissements et  
les étincelles ; prévenir toute personne sur les lieux de ne pas  
regarder l’arc.  
Porter des vêtements confectionnés avec des matières résistantes  
et ignifuges (cuir, coton lourd ou laine) et des bottes de protection.  
D
Ne pas toucher des parties chaudes à mains  
nues.  
D
Prévoir une période de refroidissement avant  
d’utiliser le pistolet ou la torche.  
D
D
Ne pas toucher aux pièces chaudes, utiliser les outils recom-  
mandés et porter des gants de soudage et des vêtements épais  
pour éviter les brûlures.  
LE SOUDAGE peut provoquer un  
incendie ou une explosion.  
Le soudage effectué sur des conteneurs fermés tels  
que des réservoirs, tambours ou des conduites peut  
provoquer leur éclatement. Des étincelles peuvent  
être projetées de l’arc de soudure. La projection  
LES CHAMPS MAGNÉTIQUES peuvent  
affecter les stimulateurs cardiaques.  
D
Porteurs de stimulateur cardiaque, rester  
à distance.  
d’étincelles,des pièces chaudes et des équipements chauds peuvent  
provoquer des incendies et des brûlures. Le contact accidentel de  
l’électrodeavec des objets métalliques peut provoquer des étincelles,  
une explosion, une surchauffe ou un incendie. Avant de commencer  
le soudage, vérifier et s’assurer que l’endroit ne présente pas de  
danger.  
D
Les porteurs d’un stimulateur cardiaque doi-  
vent d’abord consulter leur médecin avant de  
s’approcherdes opérations de soudage à l’arc,  
de gougeage ou de soudage par points.  
D
Déplacer toutes les substances inflammables à une distance de  
10,7 m de l’arc de soudage. En cas d’impossibilité, les recouvrir soi-  
gneusementavec des protections homologuées.  
LE BRUIT peut endommager l’ouïe.  
Le bruit des processus et des équipements peut  
affecter l’ouïe.  
D
D
D
Ne pas souder dans un endroit où des étincelles peuvent tomber sur  
des substances inflammables.  
Se protéger, ainsi que toute autre personne travaillant sur les lieux,  
contre les étincelles et le métal chaud.  
Des étincelles et des matériaux chauds du soudage peuvent  
facilement passer dans d’autres zones en traversant de petites  
fissures et des ouvertures.  
Afin d’éliminer tout risque de feu, être vigilant et garder toujours un  
extincteur à la portée de main.  
Le soudage effectué sur un plafond, plancher, paroi ou séparation  
peut déclencher un incendie de l’autre côté.  
Ne pas effectuer le soudage sur des conteneurs fermés tels que des  
réservoirs, tambours, ou conduites, à moins qu’ils n’aient été prépa-  
rés correctement conformément à AWS F4.1 (voir les normes de  
sécurité).  
Brancher le câble de masse sur la pièce le plus près possible de la  
zone de soudage pour éviter le transport du courant sur une longue  
distance par des chemins inconnus éventuels en provoquant des  
risques d’électrocution, d’étincelles et d’incendie.  
Ne pas utiliser le poste de soudage pour dégeler des conduites  
gelées.  
En cas de non-utilisation, enlever la baguette d’électrode du porte-  
électrode ou couper le fil à la pointe de contact.  
Porter des vêtements de protection exempts d’huile tels que des  
gants en cuir, une veste résistante, des pantalons sans revers, des  
bottes et un casque.  
D
Porter des protections approuvées pour les  
oreilles si le niveau sonore est trop élevé.  
LES BOUTEILLES peuvent exploser  
si elles sont endommagées.  
D
D
D
Des bouteilles de gaz protecteur contiennent du gaz  
sous haute pression. Si une bouteille est endomma-  
gée, elle peut exploser. Du fait que les bouteilles de  
gaz font normalement partie du procédé de soudage,  
les manipuler avec précaution.  
D
D
D
Protéger les bouteilles de gaz comprimé d’une chaleur excessi-  
ve, des chocs mécaniques, des dommages physiques, du lai-  
tier, des flammes ouvertes, des étincelles et des arcs.  
Placer les bouteilles debout en les fixant dans un support sta-  
tionnaireou dans un porte-bouteilles pour les empêcher de tom-  
ber ou de se renverser.  
Tenir les bouteilles éloignées des circuits de soudage ou autres  
circuits électriques.  
Ne jamais placer une torche de soudage sur une bouteille à gaz.  
D
D
D
D
D
D
Une électrode de soudage ne doit jamais entrer en contact avec  
une bouteille.  
D
D
Avant de souder, retirer toute substance combustible de ses poches  
D
D
Ne jamais souder une bouteille pressurisée risque d’explosion.  
telles qu’un allumeur au butane ou des allumettes.  
Utiliser seulement des bouteilles de gaz protecteur, régulateurs,  
tuyaux et raccords convenables pour cette application spécifi-  
que ; les maintenir ainsi que les éléments associés en bon état.  
Détourner votre visage du détendeur-régulateur lorsque vous  
ouvrez la soupape de la bouteille.  
Le couvercle du détendeur doit toujours être en place, sauf lors-  
que la bouteille est utilisée ou qu’elle est reliée pour usage ulté-  
rieur.  
Utiliser les équipements corrects, les bonnes procédures et suf-  
fisammentde personnes pour soulever et déplacer les bouteil-  
les.  
Lire et suivre les instructions sur les bouteilles de gaz comprimé,  
l’équipement connexe et le dépliant P-1 de la CGA (Compressed  
Gas Association) mentionné dans les principales normes de sécuri-  
té.  
Suivre les consignes de OSHA 1910.252 (a) (2) (iv) et de NFPA 51B  
pour travaux de soudage et prévoir un détecteur d’incendie et un ex-  
tincteur à proximité.  
D
D
DES  
PARTICULES  
VOLANTES  
peuvent blesser les yeux.  
D
Le soudage, l’écaillement, le passage de la  
pièce à la brosse en fil de fer, et le meulage  
génèrent des étincelles et des particules  
métalliques volantes. Pendant la période de  
refroidissement des soudures, elles risquent  
de projeter du laitier.  
D
D
D
Porter des lunettes de sécurité avec écrans latéraux ou un écran  
facial.  
OM-1581 Page 6  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2-3. Dangers supplémentaires en relation avec l’installation, le fonctionnement et la maintenance  
Risque D’INCENDIE OU D’EXPLO-  
SION.  
DES ORGANES MOBILES peuvent  
provoquer des blessures.  
D
Ne pas placer l’appareil sur, au-dessus ou  
à proximité de surfaces inflammables.  
D
S’abstenirde toucher des organes mobiles tels  
que des ventilateurs.  
D
Ne pas installer l’appareil à proximité de  
produits inflammables.  
D
Maintenir fermés et verrouillés les portes,  
panneaux, recouvrements et dispositifs de  
protection.  
D
Ne pas surcharger l’installation électrique s’assurer que  
l’alimentationest correctement dimensionnée et protégée avant  
de mettre l’appareil en service.  
D
D
Seules des personnes qualifiées sont autorisées à enlever les  
portes, panneaux, recouvrements ou dispositifs de protection  
pour l’entretien.  
Remettreles portes, panneaux, recouvrements ou dispositifs de  
protection quand l’entretien est terminé et avant de rebrancher  
l’alimentation électrique.  
LA CHUTE DE L’APPAREIL peut  
blesser.  
LIRE LES INSTRUCTIONS.  
D
Utiliser l’anneau de levage uniquement pour  
soulever l’appareil, NON PAS les chariots, les  
bouteilles de gaz ou tout autre accessoire.  
Utiliser un équipement de levage de capacité  
suffisante pour lever l’appareil.  
D
Lire le manuel d’utilisation avant d’utiliser ou  
d’intervenirsur l’appareil.  
D
D
Utiliser uniquement des pièces de rechange  
Miller/Hobart.  
D
En utilisant des fourches de levage pour déplacer l’unité, s’assu-  
rer que les fourches sont suffisamment longues pour dépasser  
du côté opposé de l’appareil.  
LE  
RAYONNEMENT  
HAUTE  
FRÉQUENCE (HF) risque de provoquer  
des interférences.  
L’EMPLOI EXCESSIF peut SUR-  
CHAUFFER L’ÉQUIPEMENT.  
D
Le rayonnement haute fréquence (HF) peut  
provoquer des interférences avec les équipe-  
ments de radio-navigation et de communica-  
tion, les services de sécurité et les ordinateurs.  
D
D
D
Prévoir une période de refroidissement ;  
respecter le cycle opératoire nominal.  
D
Demander seulement à des personnes qualifiées familiarisées  
avec des équipements électroniques de faire fonctionner l’instal-  
lation.  
L’utilisateurest tenu de faire corriger rapidement par un électri-  
cien qualifié les interférences résultant de l’installation.  
Si le FCC signale des interférences, arrêter immédiatement  
l’appareil.  
Effectuer régulièrement le contrôle et l’entretien de l’installation.  
Maintenirsoigneusement fermés les portes et les panneaux des  
sources de haute fréquence, maintenir les éclateurs à une  
distance correcte et utiliser une terre et un blindage pour réduire  
les interférences éventuelles.  
Réduire le courant ou le facteur de marche  
avant de poursuivre le soudage.  
Ne pas obstruer les passages d’air du poste.  
D
D
LES CHARGES ÉLECTROSTATIQUES  
peuvent endommager les circuits  
imprimés.  
D
D
D
Établir la connexion avec la barrette de terre  
avant de manipuler des cartes ou des pièces.  
D
Utiliser des pochettes et des boîtes antistati-  
ques pour stocker, déplacer ou expédier des  
cartes PC.  
LE SOUDAGE À L’ARC risque de  
provoquer des interférences.  
D
L’énergie électromagnétique peut gêner le  
fonctionnement d’appareils électroniques  
comme des ordinateurs et des robots.  
DES ORGANES MOBILES peuvent  
provoquer des blessures.  
D
Veiller à ce que tout l’équipement de la zone de  
D
Ne pas s’approcher des organes mobiles.  
soudage soit compatible électromagnétiquement.  
D
Ne pas s’approcher des points de coincement  
tels que des rouleaux de commande.  
D
Pour réduire la possibilité d’interférence, maintenir les câbles de  
soudage aussi courts que possible, les grouper, et les poser  
aussi bas que possible (ex. par terre).  
D
D
D
Veiller à souder à une distance de 100 mètres de tout équipe-  
LES FILS DE SOUDAGE peuvent  
provoquer des blessures.  
ment électronique sensible.  
Veiller à ce que ce poste de soudage soit posé et mis à la terre  
conformément à ce mode d’emploi.  
En cas d’interférences après avoir pris les mesures précéden-  
tes, il incombe à l’utilisateur de prendre des mesures supplé-  
mentaires telles que le déplacement du poste, l’utilisation de  
câbles blindés, l’utilisation de filtres de ligne ou la pose de protec-  
teurs dans la zone de travail.  
D
Ne pas appuyer sur la gâchette avant d’en  
avoir reçu l’instruction.  
D
Ne pas diriger le pistolet vers soi, d’autres  
personnes ou toute pièce mécanique en enga-  
geant le fil de soudage.  
2-4. Proposition californienne 65 Avertissements  
Y
Les équipements de soudage et de coupage produisent des Pour les moteurs à essence :  
fumées et des gaz qui contiennent des produits chimiques dont  
Y
Les gaz d’échappement des moteurs contiennent des produits  
l’État de Californie reconnaît qu’ils provoquent des malformations  
congénitales et, dans certains cas, des cancers. (Code de santé et  
de sécurité de Californie, chapitre 25249.5 et suivants)  
chimiques dont l’État de Californie reconnaît qu’ils provoquent  
des cancers et des malformations congénitales ou autres pro-  
blèmes de procréation.  
Pour les moteurs diesel :  
Y
Les batteries, les bornes et autres accessoires contiennent du  
plomb et des composés à base de plomb, produits chimiques  
dont l’État de Californie reconnaît qu’ils provoquent des can-  
cers et des malformations congénitales ou autres problèmes de  
procréation. Se laver les mains après manipulation.  
Y
Les gaz d’échappement des moteurs diesel et certains de leurs  
composants sont reconnus par l’État de Californie comme  
provoquant des cancers et des malformations congénitales ou au-  
tres problèmes de procréation.  
OM-1581 Page 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
2-5. Principales normes de sécurité  
Safety in Welding, Cutting, and Allied Processes, ANSI Standard Z49.1, Boulevard, Rexdale, Ontario, Canada M9W 1R3 (téléphone  
:
:
de Global Engineering Documents (téléphone : 1-877-413-5184, site In- 800-463-6727 ou  
à
Toronto 416-747-4044, site Internet  
ternet : www.global.ihs.com).  
www.csa-international.org).  
Practice For Occupational And Educational Eye And Face Protection,  
ANSI Standard Z87.1, de American National Standards Institute, 11 West  
42nd Street, New York, NY 10036-8002 (téléphone : 212-642-4900, site  
Internet : www.ansi.org).  
Recommended Safe Practices for the Preparation for Welding and Cut-  
ting of Containers and Piping, American Welding Society Standard AWS  
F4.1 de Global Engineering Documents (téléphone : 1-877-413-5184, site  
Internet : www.global.ihs.com).  
Standard for Fire Prevention During Welding, Cutting, and Other Hot  
Work, NFPA Standard 51B, de National Fire Protection Association, P.O.  
Box 9101, 1 Battery March Park, Quincy, MA 02269-9101 (téléphone :  
617-770-3000,site Internet : www.nfpa.org).  
National Electrical Code, NFPA Standard 70, de National Fire Protection  
Association, P.O. Box 9101, 1 Battery March Park, Quincy, MA  
02269-9101(téléphone : 617-770-3000, site Internet : www.nfpa.org).  
Safe Handling of Compressed Gases in Cylinders, CGA Pamphlet P-1,  
de Compressed Gas Association, 1735 Jefferson Davis Highway, Suite  
1004, Arlington, VA 22202-4102 (téléphone : 703-412-0900, site Internet  
: www.cganet.com).  
OSHA, Occupational Safety and Health Standards for General Industry,  
Title 29, Code of Federal Regulations (CFR), Part 1910, Subpart Q, and  
Part 1926, Subpart J, de U.S. Government Printing Office, Superinten-  
dent of Documents, P.O. Box 371954, Pittsburgh, PA 15250 (il y a 10  
Code for Safety in Welding and Cutting, CSA Standard W117.2, de bureaux régionaux−−le téléphone de la région 5, Chicago, est  
Canadian Standards Association, Standards Sales, 178 Rexdale 312-353-2220,site Internet : www.osha.gov).  
2-6. Information EMF  
Considérationssur le soudage et les effets de basse fréquence et des 1. Maintenir les câbles ensemble en les tordant ou en les enveloppant.  
champs magnétiques et électriques.  
2. Disposer les câbles d’un côté et à distance de l’opérateur.  
Le courant de soudage, pendant son passage dans les câbles de souda-  
ge, causera des champs électromagnétiques. Il y a eu et il y a encore un  
3. Ne pas courber pas et ne pas entourer pas les câbles autour de  
certain souci à propos de tels champs. Cependant, après avoir examiné  
votre corps.  
plus de 500 études qui ont été faites pendant une période de recherche  
de 17 ans, un comité spécial ruban bleu du National Research Council a  
4. Garder le poste de soudage et les câbles le plus loin possible de  
conclu : « L’accumulation de preuves, suivant le jugement du comité, n’a  
vous.  
pas démontré que l’exposition aux champs magnétiques et champs élec-  
triques à haute fréquence représente un risque à la santé humaine ».  
5. Connecter la pince sur la pièce aussi près que possible de la sou-  
Toutefois, des études sont toujours en cours et les preuves continuent à  
dure.  
être examinées. En attendant que les conclusions finales de la recherche  
soient établies, il vous serait souhaitable de réduire votre exposition aux  
champs électromagnétiques pendant le soudage ou le coupage.  
En ce qui concerne les stimulateurs cardiaques  
Les porteurs de stimulateur cardiaque doivent consulter leur médecin  
Pour réduire les champs magnétiques sur le poste de travail, appliquer avant de souder ou d’approcher des opérations de soudage. Si le méde-  
les procédures suivantes :  
cin approuve, il est recommandé de suivre les procédures précédentes.  
OM-1581 Page 8  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
SECTION 3 SPECIFICATIONS  
3-1. Wire Feeder Specifications  
Specification  
Description  
Type Of Input Power  
115 Volts AC, 3 Amperes At 50/60 Or 100 Hz Power  
30 Volts DC  
Control Circuit Voltage Provided At Gun  
Wire Feed Speed Range  
Overall Dimensions  
70-875 ipm (1.9-22.2 mpm)  
Length: 19 in (483 mm); Width: 9-1/4 in (235 mm); Height: 15-1/4 in (387 mm)  
12 in (305 mm)  
Maximum Spool Capacity  
Cooling Method  
Air-Cooled (A Models) Or Water-Cooled (W Models)  
Weight (Feeder With Gun)  
Models With 15 ft (4.6 m) Cable Assembly  
Net: 56 lb (25 kg); Ship: 58 lb (26 kg)  
Models With 30 ft (9.1 m) Cable Assembly  
Net: 63 lb (29 kg); Ship: 65 lb (30 kg)  
3-2. Gun Specifications  
Specification  
Description  
Input Voltage  
30 Volts DC  
Duty Cycle (Air-Cooled Models)  
At 200 Amperes, 100% Using Argon Or Argon Mixture Shielding Gas  
At 250 Amperes, 60% Using Argon Or Argon Mixture Shielding Gas (See  
Duty Cycle (Water-Cooled Models)  
Wire Size Range  
At 400 Amperes, 100% Using Argon Or Argon Mixture Shielding Gas (See Sec-  
.030 Thru 1/16 in (0.8 Thru 1.6 mm) Aluminum Wire  
.030 Thru .045 in (0.8 Thru 1.1 mm) Hard Or Cored Wire  
3-3. Duty Cycle And Overheating  
Duty Cycle is percentage of 10 min-  
utes that unit can weld at rated load  
without overheating.  
Y
Exceeding duty cycle can  
damage unit and void  
warranty.  
Air-Cooled Models  
100% Duty Cycle At 200 Amperes Using Argon  
60% Duty Cycle At 250 Amperes Using Argon  
Continuous Welding  
6 Minutes Welding  
Water-Cooled Models  
4 Minutes Resting  
100% Duty Cycle At 400 Amperes Using Argon  
Continuous Welding  
OM-1581 Page 9  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
SECTION 4 INSTALLATION  
Be sure that contact tip, liner, and drive rolls are correct for wire size and type. See  
Section 5 to change parts as needed. See Section 7 for list of other available  
contact tips.  
NOTE  
Review Section 4-1 through Section 4-4 to determine how equipment will be connected. Air-cooled models are shown  
in Section 4-1 through Section 4-4. For water-cooled models, supplied water hoses must be connected from wire feed-  
er to coolant supply.  
4-1. Connections With A CC, CV Or CC/CV Voltage Welding Power Source Having A  
14-Socket Receptacle  
1
Constant Current (CC),  
Constant Voltage (CV) Or  
Constant Current/Constant  
Voltage (CC/CV) Welding  
Power Source  
2
115 VAC/Contactor Control  
14-Pin Plug  
3
4
Workpiece  
1
Voltage Sensing Lead  
Connect lead to workpiece for CC  
welding only.  
5
6
7
Gun  
2
8
Wire Feeder  
115 VAC/Contactor Control  
Cord  
8
Gas Cylinder  
3
4
7
5
6
151 774-F  
OM-1581 Page 10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
4-2. Connections With A CV Welding Power Source Having Separate 115 VAC And  
Contactor Control Receptacles  
1
Constant Voltage (CV) Weld-  
ing Power Source  
1
2
Plug  
2
Obtain matching plugs for connect-  
ing to power source receptacles.  
8
3
4
Workpiece  
Voltage Sensing Lead  
Do not connect to workpiece.  
5
6
7
Gun  
Wire Feeder  
115 VAC/Contactor Control  
Cord  
8
Gas Cylinder  
3
7
4
5
6
151 775-G  
4-3. Connections With A CC Welding Power Source Having A Contactor Control  
Receptacle  
1
Constant Current (CC) Weld-  
ing Power Source  
1
2
5-Pin Or Two-Prong Twistlock  
Plug  
10  
9
3
4
5
6
7
Workpiece  
2
Voltage Sensing Lead  
Gun  
Wire Feeder  
3-Conductor Contactor Con-  
trol Cord  
8
9
3-Conductor 115 VAC Cord  
Gas Cylinder  
10 115 VAC Plug  
Obtain plug for wire feeder.  
3
8
4
7
5
6
151 776-F  
OM-1581 Page 11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
4-4. Connections With A CC Welding Power Source And A 115 VAC/12 VDC Secondary  
Contactor  
1
Constant Current (CC) Weld-  
ing Power Source  
2
3
4
5
6
7
Workpiece  
Voltage Sensing Lead  
Gun  
1
Wire Feeder  
3-Conductor 115 VAC Cord  
3-Conductor Contactor Con-  
trol Cord  
10  
11  
8
9
5-Pin Plug  
Secondary Contactor  
10 Gas Cylinder  
11 115 VAC Plug  
Obtain plug for wire feeder.  
2
9
8
3
7
6
4
5
151 777-F  
4-5. Removing Top Cover Of Pistol Grip Gun  
1
Top Cover Triangular Boss  
Push up on triangular boss to open  
door. Door hinges on handle.  
1
To open door fully, push up on door  
until it clicks into position.  
. If door is pushed too far it will  
separate from handle. If this  
happens the door can be rein-  
stalled.  
Push door back into original posi-  
tion to close.  
802 528-C  
OM-1581 Page 12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
4-6. Air-Cooled Gun Connections  
1
Gun Control Cable  
Insert plug into Gun Control recep-  
tacle, and tighten threaded collar.  
2
Gas Hose  
Connect to Gas fitting on feeder.  
3
4
Weld Cable  
Weld Cable Terminal In  
Feeder  
Connect gun weld cable to weld  
cable terminal in feeder.  
5
6
7
8
Wire Conduit  
Thumbscrew  
Wire Conduit Block  
Strain Relief  
6
5
. For guns that have wire con-  
duits with replaceable liners,  
the strain relief will need to be  
removed from the control box.  
7
4
Loosen thumbscrew, and insert  
conduit through wire opening until  
it bottoms against block. Trim liner  
if necessary, as close to the rolls  
as possible. Tighten thumbscrew.  
Close and latch door.  
3
Left Side  
8
5
2
3
1
Tools Needed:  
5/8, 3/4 in  
145 432-C / Ref. 802 536-E / Ref. 151 778-B  
OM-1581 Page 13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
4-7. Water-Cooled Gun Connections  
1
Gas Hose  
Connect to Gas fitting on feeder.  
Water Hose  
2
Connect to water to gun fitting on  
feeder (left-hand threads).  
3
4
5
Wire Conduit  
Thumbscrew  
Wire Conduit Block  
Loosen thumbscrew, and insert  
conduit through Wire opening until  
it bottoms against block. Trim liner  
if necessary, as close to the rolls  
as possible. Tighten thumbscrew.  
6
Gun Control Cable  
Insert plug into gun control recep-  
tacle, and tighten threaded collar.  
4
3
7
Strain Relief  
Remove strain relief as shown.  
8
9
Power/Water Cable  
Strain Relief  
. For guns that have wire con-  
duits with replaceable liners,  
the strain relief will need to be  
removed from the control box.  
5
Left Side  
Route cable through strain relief  
and connect to weld/water from gun  
outlet on feeder. Reinstall strain re-  
lief. Close and latch door.  
9
3
2
1
7
8
6
Tools Needed:  
5/8, 1-1/8 in  
Ref. 802 536-E / Ref. 151 778-B / 152 456-A  
OM-1581 Page 14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
4-8. Air-Cooled Feeder Connections  
1
2
3
Gas Hose Grommet  
10 ft (3 m) Gas Hose  
Rear Of Gas Fitting  
Route one end of gas hose through  
grommet, and connect hose to rear  
of Gas fitting in feeder. Connect  
remaining end of hose to  
regulator/flowmeter.  
4
Weld Cable To Welding Power  
Source  
Select and prepare weld cable ac-  
cording to welding power source  
manual.  
5
6
7
Weld Cable Grommet  
Current Sensing (Reed) Relay  
Weld Cable Terminal In  
Feeder  
Route one end of weld cable  
through grommet, through reed  
relay, and connect to weld cable  
terminal in feeder. Connect  
remaining end of cable to positive  
(+) weld output terminal on welding  
power source.  
2
4
6
7
3
8
Gun Weld Cable  
Be sure that terminal of welding  
power source weld cable is in direct  
contact with terminal from gun weld  
cable. Close and latch door.  
7
4
8
Rear Panel  
Top View  
1
Connect To  
5
Positive (+) Weld  
Output Terminal On  
Welding Power Source  
Connect To  
Regulator/  
Flowmeter  
Tools Needed:  
5/8, 1-1/8 in  
Ref. 151 771-A  
OM-1581 Page 15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
4-9. Water-Cooled Feeder Connections  
Obtain coolant supply.  
1
2
3
Gas Hose Grommet  
10 ft (3 m) Gas Hose  
Rear Of Gas Fitting  
Route one end of gas hose through  
grommet, and connect hose to rear  
of Gas fitting in feeder. Connect  
remaining end of hose to  
regulator/flowmeter.  
5
6
4
5
6
Coolant Supply Hose  
Grommet  
10 ft (3 m) Water Supply Hose  
With 5/8 in Adapter Fitting  
Rear Of Water Fitting (Left-  
Hand Threads)  
Remove 5/8 in adapter fitting from  
hose. Route one end of a water  
hose through grommet, and con-  
nect to rear of Water To Gun fitting  
in feeder. Connect remaining end to  
supply fitting on coolant supply.  
2
11  
12  
9
3
11  
7
Coolant Return Hose  
Grommet  
8
9
10 ft (3 m) Water Return Hose  
Connection Block (Left-Hand  
Threads)  
Route one end of remaining water  
hose through grommet, and con-  
nect to rear of connection block (not  
shown). Connect remaining end of  
hose to return fitting on coolant  
supply.  
13  
Top View  
10 Weld Cable Grommet  
11 Weld Cable To Welding Power  
Source  
Rear Panel  
Select and prepare weld cable  
according to welding power source  
manual.  
12 Current Sensing (Reed) Relay  
13 Weld Cable Screw In Feeder  
Route one end of weld cable  
through grommet, through reed  
relay, and connect to block in feeder  
using hardware shown. Connect  
remaining end of cable to positive  
(+) weld output terminal on welding  
power source.  
Close and latch door.  
8
7
10  
4
1
Tools Needed:  
5/8, 1-1/8 in  
Connect To  
Connect To  
Return Fitting On  
Coolant Supply  
Positive (+) Weld  
Connect To  
Supply Fitting On  
Coolant Supply  
Connect To  
Regulator/  
Flowmeter  
Output Terminal On  
Welding Power Source  
Ref. 152 431-A  
OM-1581 Page 16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
4-10. Voltage Sensing Lead Connections  
Unit is factory set for constant volt-  
age (CV) welding. To set unit for  
constant current (CC) welding,  
proceed as follows:  
1
2
Terminal Strip 2T  
Strain Relief  
Loosen screws of strain relief.  
Voltage Sensing Lead  
3
Route ring terminal end of lead  
through strain relief, and connect  
ring terminal to terminal  
terminalstrip 2T. Tighten screws on  
strain relief.  
A
of  
2
3
4
Motor Speed Control Board  
PC1  
5
6
Jumper Plug  
Receptacle RC5  
For constant voltage (CV) welding,  
place jumper plug in INT. position.  
Do not connect voltage sensing  
lead clamp to workpiece.  
For constant current (CC) welding,  
place plug in EXT. position.  
Connect clamp end of voltage  
sensing lead to workpiece.  
3
1
Reinstall right side panel.  
5
4
6
E
D
C
B
A
3
2
1
EXT INT  
Tools Needed:  
1/4 in  
Ref. 151 772-B  
OM-1581 Page 17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
4-11. 115 VAC/Contactor Control Plug Information  
1
2
InterconnectingCord  
115 VAC/Contactor Control  
Plug PLG5  
If CC or CC/CV welding power  
source is equipped with matching  
14-socket receptacle, insert plug,  
and tighten threaded collar.  
Proceed to Section 4-13.  
If plug PLG5 will not connect to CC  
welding power source receptacle,  
use the following pin information  
and Section 4-12 to replace PLG5  
with a suitable plug.  
J
A
K
I
B
C
L
H
N
M
E
G
D
F
1
2
Pin*  
Pin Information  
A, B  
I
Contact closure to A completes contactor control circuit.  
115 volts ac.  
Remote  
Contactor  
J
Contact closure to I completes 115 volts ac contactor control circuit.  
Circuit common for 115 volts ac circuit.  
+10 volts dc output to remote control.  
Remote control circuit common.  
G
C
D
E
Remote  
Voltage Control  
0 to +10 volts dc input command signal from remote control.  
Chassis common.  
K
*The remaining pins are not used.  
Ref. S-0004-A / Ref. 151 772  
OM-1581 Page 18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
4-12. Replacing 115 VAC/Contactor Control Plug With Customer-Supplied 5-Pin Or  
Twistlock Plug  
1
115 VAC/Contactor Control  
Plug PLG5  
2
3
Contactor Control Cord  
115 VAC Cord  
Find and label cords by following  
leads to back of PLG5:  
Contactor control cord connects to  
pins A & B of PLG5  
115 VAC cord connects to pin J of  
PLG5.  
OR  
2
5
4
Cut off plug PLG5.  
4
5
5-Pin Plug  
Two-Prong Twistlock Plug  
For connections shown in Figure  
3-3 or Figure 3-4, install 5-pin or  
twistlock plug onto contactor con-  
trol cord.  
1
For Figure 3-2 connection, obtain  
plug to match contactor control  
receptacle on welding power  
source, and install plug onto  
contactor control cord.  
Obtain 115 VAC plug and connect  
to 115 VAC cord as follows:  
green lead to ground  
white lead to 115 VAC common  
black lead to 115 VAC hot.  
3
6
7
8
Plug PLG50  
Plug PLG51  
Plug PLG52  
Unit shipped with PLG50 con-  
nected to PLG51 to provide 115  
VAC for contactor.  
If contact closure needed for con-  
tactor, connect PLG50 to PLG52.  
8
Tools Needed:  
7
6
151 773-C  
OM-1581 Page 19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
4-13. Installing Wire Spool  
Turn Off wire feeder and welding  
power source.  
1
2
3
4
Wire Spool  
Top Cover  
Pressure Roll Assembly  
Gun Contact Tip  
If wire spool is being replaced, open  
pressure roll assembly in gun, and  
cut welding wire off at contact tip.  
For welding power sources without  
contactor, retract wire onto spool.  
For welding power sources with a  
contactor, energize power source,  
turn On feeder, press Brake  
and retract wire onto spool.  
Close gun pressure roll assembly  
and reinstall top cover.  
5
6
7
Hub  
Hub Pin  
Compression Spring (Optional  
For 8 in Spool)  
8
Retaining Ring  
Slide spool onto hub so wire feeds  
off bottom. Turn spool until hub pin  
fits hole in back of spool. Reinstall  
retainingring.  
Thread welding wire (see Section  
4-14). Close and latch door or go on  
to Section 4-14.  
6
2
5
1
3
7
8
4
Tools Needed:  
Ref. 151 771-A / Ref. 072 573-B / Ref. 151 599-F  
OM-1581 Page 20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
4-14. Threading Welding Wire Through Feeder  
1
Wire Spool  
Loosen wire from spool, cut off bent  
wire, and pull 6 in (150 mm) of wire  
off spool.  
2
3
Tension Arm  
Mounting Arm  
8
To open pressure roll assembly,  
open tension arm and lift mounting  
arm.  
4
5
6
Wire Inlet Guide  
Drive Roll  
Wire Conduit Fitting  
Thread wire through wire inlet  
guide, along drive roll groove, and  
into fitting.  
7
Close and secure pressure roll  
assembly.  
7
8
Tension Thumbnut  
Jog Switch  
1
Turn On wire feeder. For proper ad-  
justment, loosen thumbnut until  
drive roll slips when Jog switch is  
pushed up. Grasp spool with one  
hand, and turn thumbnut clockwise  
until motor stalls when Jog switch is  
pushed up.  
3
2
Feed welding wire through gun (see  
Section4-15). Turn Off wire feeder.  
Close and latch door.  
4
5
6
Tools Needed:  
151 778-B / Ref. 176 700-A  
OM-1581 Page 21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
4-15. Threading Welding Wire Through Gun  
1
Pressure Roll Assembly  
Lift arm and open pressure roll  
assembly.  
2
Wire Conduit  
Lay wire conduit out straight.  
Jog Switch  
3
Push Jog switch up to feed wire  
through wire conduit.  
3
4
Drive Roll  
6
2
For wire sizes .035 in (0.9 mm) and  
smaller use small groove, and  
.047 in (1.2 mm) and 1/16 in  
(1.6 mm) use large groove.  
5
Contact Tip  
Manually thread wire along drive  
roll groove and out contact tip 2 in  
(51 mm). Close pressure roll  
assembly.  
6
7
8
Tension Thumbnut  
4
Pressure Adjustment Knob  
Final Pressure Adjustment  
7
Turn On feeder and check drive roll  
pressure by feeding wire against a  
piece of wood or concrete surface;  
wire should feed steadily without  
slipping. If necessary, adjust  
pressure adjustment knob in gun.  
8
1
Turn Off feeder and welding power  
source. Reinstall gun cover. Close  
and latch feeder door.  
5
WOOD  
151 599-F / 151 666-E / Ref. 176 700-A / Ref. S-0651  
4-16. Coolant Guidelines  
CAUTION  
INCORRECT COOLANT OR COOLANT CONTAINING STOP-LEAK ADDITIVES can corrode and/or plug  
gun/feeder cooling passages.  
Use only a mix of 50% distilled water and 50% high quality automotive antifreeze as proper coolant for this product.  
Do not use antifreeze containing stop-leak additives.  
Use of other coolant voids warranty.  
Follow these guidelines to  
decrease corrosion in gun/feeder  
and cooling system:  
1
50 50  
Distilled  
Water &  
Antifreeze  
1
Coolant  
Mix distilled water and high quality  
automotive antifreeze. Use anti-  
freeze which does not contain stop-  
leak additives.  
2
Use of other coolant voids  
warranty.  
FULL  
2
3
Coolant System Tank  
Changing Coolant  
Change coolant only if dirty.  
Add coolant to keep level full.  
Draining  
Filling  
Tighten Connections  
4
4
Tighten Connections  
Keep gun connections tight.  
3
S-0760  
OM-1581 Page 22  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
4-17. Adjusting Wire Feed Starting Speed  
To adjust wire feed starting speed,  
proceed as follows:  
Turn Off wire feeder and welding  
power source. Open right side  
panel.  
1
Motor Speed Control Board  
PC1  
2
Motor Start Control  
Potentiometer R70  
Turn potentiometer clockwise to  
increase time it takes the motor to  
ramp up to speed. Remove  
protective white rubber cap before  
making  
adjustment.  
Adjust  
small  
potentiometer using  
a
nonconductivescrewdriver.  
Close side door.  
Top Of PC1  
1
2
Tools Needed:  
Nonconductive  
1/4 in  
Ref. 151 772-B / Ref. 142 054-B  
OM-1581 Page 23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
SECTION 5 OPERATION  
5-1. Front Panel Controls Of Feeder (Air-Cooled Model Shown)  
1
2
Voltage/WireSpeed Meter  
(Optional)  
1
Voltage/Wire Speed Switch  
(Optional)  
2
3
4
3
4
5
Run-In Speed Control  
Jog Switch  
Burnback Time Control  
(Optional)  
11  
6
7
Spot/Continuous Switch  
(Optional)  
5
Remote Voltage Control  
(Optional)  
6
8
9
Power Switch  
7
Time Range Switch (Optional)  
10  
10 Spot Time Control (Optional)  
11 Flowmeter (Optional)  
9
8
151 780A  
5-2. Safety Equipment  
1
2
3
Wear the following while welding:  
1
2
Dry, Insulating Gloves  
Safety Glasses With Side  
Shields  
3
Welding Helmet With Correct  
Shade Of Filter (See ANSI  
Z49.1)  
sb3.1 1/94  
5-3. Work And Voltage Sensing Cable Clamps  
1
Work Clamp  
Connect work clamp to a clean,  
paint-freelocation on workpiece, as  
close to weld area as possible.  
1
Use wire brush or sandpaper to  
clean metal at weld joint area.  
2
2
Voltage Sensing Cable Clamp  
Connect voltage sensing cable  
clamp to workpiece for constant  
current (CC) operations (see  
Section 4-10).  
Tools Needed:  
sb4.1* 2/93 Ref. 144 451-A  
OM-1581 Page 24  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
5-4. Run-In Speed Control  
1
Run-In Speed Control  
Use control to set wire feed speed  
before arc initiation.  
1
After arc initiation, wire feed speed  
is controlled by the Wire Speed  
Control on the welding gun (see  
Section 5-12).  
The scale around the control is per-  
cent of full range, not wire speed.  
As a general rule, set run-in speed  
lower than welding wire feed speed.  
Set control at 0 (zero) for scratch  
start.  
Ref. 176 700-A  
5-5. Jog Switch  
1
Jog Switch  
Use switch to energize drive mo-  
tors in feeder and gun without ener-  
gizing welding power source con-  
tactor. When switch is held up in  
Jog position, wire speed is set by  
Wire Speed Control on gun.  
1
5-6. Voltage/Wire Speed Switch And Meter (Optional)  
1
2
Voltage/WireSpeed Meter  
Voltage/Wire Speed Switch  
Volt sensing lead must be con-  
nected to workpiece for me-  
ters to operate.  
When switch is in Voltage position,  
and operator is welding, meter dis-  
plays arc voltage. Cable resistance  
and poor connections may cause  
displayed voltage to vary slightly  
from actual voltage at welding arc.  
When switch is in Wire Speed posi-  
tion and operator is welding, meter  
displays preset wire speed in in-  
ches per minute. This wire speed is  
set by Wire Speed Control on the  
gun.  
1
2
During run-in portion of weld cycle,  
meter displays run-in speed as se-  
lected on Run-In Speed control on  
feeder (see Section 5-4).  
When welding Direct Current Elec-  
trode Negative (DCEN), meter  
does not display accurate output  
voltages; however, meter displays  
accurate wire speed values.  
OM-1581 Page 25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
5-7. Spot Controls (Optional)  
1
Spot/ContinuousSwitch  
Use switch to select either an un-  
timed continuous weld cycle or a  
timed spot weld cycle. Both weld  
cycles consist of the following  
steps: run-in, weld (untimed or spot  
time), and burnback.  
2
Time Range Switch  
Use switch to select spot weld time  
range.  
3
4
3
Spot Time Control  
Use control to set spot weld time.  
Welding wire feeds at speed se-  
lected on the gun Wire Speed Con-  
trol. Spot time starts at arc initiation.  
The scale around the control is  
marked in seconds.  
4
Burnback Time Control  
Use control to adjust time (up to 0.25  
seconds) that the welding wire is  
electrically energized after the wire  
stops feeding.  
2
1
If welding wire sticks in the weld  
puddle, increase burnback time. If  
wire burns back into the gun contact  
tip, decrease burnback time.  
The scale around the control is  
marked in fractions of a second.  
5-8. Remote Voltage Control (Optional)  
1
Voltage Control  
Use control to adjust arc voltage at  
the wire feeder.  
1
The scale around the control is  
marked in percent.  
5-9. Power Switch  
1
Power Switch  
1
Use switch to turn unit On and Off.  
OM-1581 Page 26  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
5-10. Flowmeter (Optional)  
CAUTION  
Wire feeding system is designed for maximum of 50 psi (345 kPa) gas pressure.  
Be sure that regulator/flowmeter has preset conditions of no more than 50 psi (345 kPa) gas pressure.  
1
2
Flowmeter  
Valve  
Use flowmeter to control shielding  
gas flow at the feeder. The scale on  
the flowmeter is in cubic feet per  
hour (CFH). Read gas flow at the  
widest part of the float in the meter.  
Rotate valve to change gas flow as  
necessary.  
1
CFH  
Ar  
CO  
2
60  
60  
50  
A regulator is still required on  
shielding gas supply with this  
option.  
50  
40  
40  
30  
20  
30  
20  
10  
10  
2
S-0659  
5-11. Internal Controls  
Open left side door.  
1
Fuse F1  
Circuit Breaker CB1  
Motor Torque Switch  
2
3
Use switch to select the force used  
to push wire. The up position is for  
low force, or torque. The down  
position is for high force, or torque.  
1
2
If welding wire appears to be  
kinked, nicked, or damaged, place  
switch in low torque position.  
4
Brake Release Button  
3
4
Whenever power is On and the  
welding power source is energized,  
button may be pressed to release  
spool brake so wire spool can turn  
freely.  
LOW TORQUE  
HIGH TORQUE  
BRAKE  
RELEASE  
Close and latch door.  
Ref. 151 779 / Ref. S-120 552-A  
OM-1581 Page 27  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
5-12. Gun Controls  
1
Gun Trigger  
Press trigger to energize welding  
power source contactor (if applica-  
ble), start shielding gas flow, and  
begin wire feed.  
For shielding gas preflow and post-  
flow, partially press trigger before  
and partially release after welding.  
2
Wire Speed Control  
Use control to adjust wire feed  
speed. The numbers around the  
control are for reference only.  
1
2
Ref. 151 666-E  
5-13. Shielding Gas  
1
2
3
ShieldingGas Cylinder  
Valve  
2
Gun Trigger  
1
Open valve on cylinder just before  
welding.  
Gun trigger turns weld output and  
gas flows on and off (see Section  
5-12).  
Close valve on cylinder when  
finished welding.  
3
sb5.1 6/92 S-0621-C / Ref. 151 666-E  
5-14. Coolant Supply For Water-Cooled Models Only  
1
Coolant Supply  
See Section 4-16 for coolant  
guidelines.  
1
Turn On coolant supply before  
welding.  
Turn Off coolant supply when  
finished welding.  
Ref. 150 755-A  
5-15. Sequence Of Gas Metal Arc Welding (GMAW) Continuous Or Spot  
Install &  
Connect  
Equipment  
Put On  
Personal Safety  
Equipment  
Turn On Gas  
And Water (If  
Applicable)  
Turn On Feeder  
And Welding  
Power Source  
Begin Welding  
Set Controls  
ssb6.1* 9/92  
OM-1581 Page 28  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
SECTION 6 MAINTENANCE & TROUBLESHOOTING  
6-1. Routine Maintenance  
Turn Off all power before maintaining.  
3 Months  
6 Months  
3 Months  
Tape Or  
Blow Out  
Replace  
Unreadable  
Labels  
Replace  
Cracked  
Weld  
OR  
Or  
See  
Section  
7
Vacuum  
Inside  
− −  
− −  
Cable  
Clean  
And  
Tighten  
Weld  
Terminals  
During Heavy Service,  
Clean Monthly  
Replace  
Cracked  
Parts  
− −  
Clean  
Drive  
Rolls  
14-Pin Cord  
5-2  
Gas Hose  
Gun Cable  
OM-1581 Page 29  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
6-2. Changing Or Cleaning Gun Drive Roll  
Turn Off wire feeder and welding  
power source.  
1
2
Top Cover  
Pressure Roll Assembly  
Cut off wire where it enters  
pressure roll assembly area.  
3
4
Setscrew  
Current Pick-Up Tab  
5
This tab helps prevent burnback  
caused by welding arcs inside the  
contact tip. This tab may be re-  
moved to provide an insulated drive  
roll. (If tab is removed, a smaller di-  
ameter contact tip is recom-  
mended.See options in Parts List.)  
Lightly grease top of tab before rein-  
stalling.  
3
1
4
5
Drive Roll  
Use wire brush to clean drive roll.  
Install drive roll with desired groove  
down, and turn drive roll so one  
setscrew faces flat side of shaft.  
6
7
Bearing  
Liner  
Line up drive roll groove with bear-  
ing groove and liner opening.  
Tighten setscrews.  
If changing drive roll in feeder,  
proceed to Section 6-3.  
Thread welding wire through gun,  
and adjust drive roll pressure, if  
necessary (see Section 4-15).  
Close and secure pressure roll  
assembly. Reinstall top cover.  
2
6
7
Tools Needed:  
5/64 in  
Ref. 151 599-F  
OM-1581 Page 30  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
6-3. Changing Feeder Drive Roll And Wire Inlet Guide  
Turn Off wire feeder and welding  
power source. Lay wire conduit out  
straight.  
Open gun pressure roll assembly,  
and cut welding wire off at contact  
tip.  
1
2
Pressure Roll Assembly  
Wire Spool  
For welding power sources without  
contactor, retract wire onto spool.  
2
For welding power sources with a  
contactor, energize power source,  
turn On feeder, press Brake Re-  
lease button, and retract wire onto  
spool.  
6
3
4
5
Shaft  
Setscrew  
Drive Roll  
Use wire brush to clean drive roll.  
Install drive roll with desired groove  
in, and turn drive roll so one  
setscrew faces flat side of shaft.  
1
7
6
7
Bearing  
Wire Conduit Fitting  
Line up drive roll groove with bear-  
ing groove and opening in conduit  
fitting. Tighten setscrews.  
8
Wire Inlet Guide  
Pull guide toward rear of feeder to  
remove. Install new guide.  
Thread welding wire and adjust  
drive roll pressure, if necessary  
(see Section 4-14). Close and se-  
cure pressure roll assembly. Close  
and latch door.  
8
Close gun pressure roll assembly,  
and reinstall gun cover.  
4
3
5
Tools Needed:  
5/16 in  
151 778 / Ref. 151 781-B  
OM-1581 Page 31  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
6-4. Replacing Or Cleaning Gun Drive Roll Bearing  
Turn Off wire feeder and welding  
power source.  
1
2
3
4
Top Cover  
Pressure Roll Assembly  
Screw  
1
Pressure Roll  
Remove as shown.  
Use a wire brush to clean bearing.  
Reinstall with washers, and tighten  
screw.  
Close pressure roll assembly.  
Reinstall top cover.  
4
3
Tools Needed:  
2
Ref. 151 599F  
6-5. Replacing Or Cleaning Feeder Drive Roll Bearing  
Turn Off wire feeder and welding  
power source.  
1
2
3
4
5
6
7
Pressure Roll Assembly  
Retaining Ring  
Mounting Arm  
Hinge Pin  
Screw  
Shoulder Washer  
Drive Roll Bearing  
1
Remove as shown.  
Use a wire brush to clean bearing.  
Reinstall, and tighten screw.  
Close pressure roll assembly.  
Close and latch door.  
6
7
6
2
5
Tools Needed:  
3
4
151 778 / Ref. 151 781-B  
OM-1581 Page 32  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
6-6. Changing Gun Contact Tip  
Remove nozzle  
1
2
Nozzle  
FasTip  
Unscrew FasTip.  
Install new FasTip.  
2
1
Ref. 150 437-A  
6-7. Removing Diffuser In Air And Water-Cooled Pistol-Grip Guns  
WARNING  
WATER IN GUN PARTS can cause ELECTRIC SHOCK and can lower weld quality.  
Turn Off welding power source and water supply before working on gun. Stop engine on welding generators.  
Always point gun downward when removing water-cooled barrel to keep water out of gun parts.  
Wipe gun dry before putting it back together.  
Turn Off welding power source.  
1
2
Nozzle  
FasTip  
Diffuser  
Remove diffuser and replace.  
3
1
2
3
Air Cooled Head Tube Assembly  
Tools Needed:  
3/8 in  
Ref. 803 348-G  
OM-1581 Page 33  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
6-8. Replacing The Liner  
Y
Turn Off welding power  
source and wire feeder.  
1
2
Drive Roll  
Collet Nut  
Lay gun cable out straight. Remove  
drive roll on gun and collet nut on on  
both ends of liner tube assembly  
and remove old liner.  
3
New Liner  
Insert split end of new liner into liner  
tube assembly and continue feed-  
ing liner through cable assembly  
until liner is through liner tube as-  
sembly and all of split portion is vis-  
ible.  
1
. If gun is a 15 ft (4.5 m) model,  
push the split end of liner  
through until the opposite end  
is sticking out of the gun con-  
nector 1 to 2 inches (2.5 to 5  
cm). After trimming, the section  
with the split on it can be saved  
to use as another replacement  
liner.  
2
Cut off split portion of liner. Replace  
front collet nut with new plastic nut  
from the liner kit. Reinstall steel nut  
at gun connector and tighten onto  
liner.  
. May be easier to replace the  
collet nut with the liner conduit  
removed from the gun housing  
block.  
The liner end will not stick out of the  
plastic collet nut supplied with the  
liner kit.  
At the gun connection end, cut liner  
as close as possible to control  
(push motor) drive rolls.  
2
Refer to Owner’s Manual for in-  
structions on rethreading wire.  
3
Split End  
Ref. 802 536-E / 151 599-F / 200 371  
OM-1581 Page 34  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
6-9. Replacing Hub Assembly  
Turn Off wire feeder and welding  
power source. Remove gun top  
cover and open pressure roll  
assembly as shown in Section 6-4.  
Retract wire onto spool and remove  
spool. Take hub apart as shown.  
1
2
3
4
5
6
7
8
Metal Brake Washer  
Flat Washer  
Brake Washer  
Hub  
Keyed Washer  
Spring  
Cap Screw  
Retaining Ring  
Replace broken or worn parts and  
slide parts onto shaft as shown.  
Adjust hub tension (see Section  
6-10). Thread welding wire (see  
Section4-14). Close and latch door.  
1
Close gun pressure roll assembly  
and reinstall gun cover.  
2
5
3
6
4
2
7
Tools Needed:  
7/16 in  
8
151 778-B / Ref. 143 223-A  
OM-1581 Page 35  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
6-10. Adjusting Hub Tension  
Turn On welding power source and  
wire feeder to make this  
adjustment.  
1
Wire Speed Control  
Adjust control to wire speed for  
welding.  
2
Jog Switch  
Push up, and then release Jog  
switch. Hub tension is okay if wire  
unwinds freely, but wire does not  
backlash when Jog switch is  
released.  
2
3
1
3
Cap Screw  
Turn cap screw to adjust hub ten-  
sion. Do not overtighten. Turn Off  
welding power source and wire  
feeder. Close and latch door.  
Tools Needed:  
7/16 in  
151 666-E / Ref. 802 536 / Ref. 176 700-A  
6-11. Overload Protection  
Turn Off wire feeder and welding  
power source.  
If F1 opens, the unit shuts down. To  
check or change F1, proceed as  
follows:  
1
2
Fuse Holder Cover  
3
Fuse F1 (See Parts List For  
Rating)  
1
Push And Turn  
2
Insert new fuse into cover, and in-  
stall fuse with cover by pressing and  
turning cover clockwise.  
3
Circuit Breaker CB1  
If CB1 opens, the gun drive motor  
and contactor will not operate, but  
gas flows when trigger is pulled. The  
gun drive motor operates in the Jog  
mode with CB1 open.  
Check for blocked gun liner.  
Pull Out And Replace F1  
Check for jammed wire, binding  
drive gear or misaligned drive rolls  
in feeder. Correct problem.  
Allow cooling period and manually  
reset breaker. Close and latch door.  
Push And Turn  
Ref. 151 779-A / Ref. 800 185-A  
6-12. Water Flow Switch (Optional For Water-Cooled Models)  
The water flow switch protects the gun from overheating. If coolant flow rate drops below 1 qt/min, the water flow  
OM-1581 Page 36  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
6-13. Troubleshooting  
A. Wire Feeder Trouble  
Trouble  
Remedy  
feeder. Welding wire is not energized.  
Shieldinggas flows.  
Check for kinks in water hose.  
Be sure coolant supply is turned On (see Section 5-14).  
Have nearest Factory Authorized Service Station/Service Distributor check optional water flow switch,  
if applicable (see Section 6-12).  
Wire feeds, shielding gas flows, but Secure 115 VAC/contactor control plug connection (see Section 4-11).  
welding wire is not energized.  
See Troubleshooting section in welding power source manual.  
Check plug PLG50, PLG51 and PLG52 connections (see Section 4-12).  
Wire feeds erratically.  
Check position of Motor Torque switch (see Section 5-11).  
Adjust drive roll pressure if necessary (see Section 4-14).  
Replace or clean drive rolls as necessary (see Sections 6-2 and 6-3).  
Arc varies and welding wire is kinked Place Motor Torque switch in low torque position if welding with .030 (0.8 mm) aluminum welding wire (see  
when feeding out gun. Section 5-11).  
Pressing gun trigger will not feed wire, Reset circuit breaker CB1 (see Section 6-11).  
wire is not energized, shielding gas  
flows, and Jog switch activates motor.  
Feeder feeds wire but remains in run-in Route weld cable through current sensing relay (see Section 4-8).  
mode after arc initiation.  
If constant current (CC) welding, be sure PLG5 is in EXT. position on PC1, and voltage sensing lead is  
If constant voltage (CV) welding, be sure PLG5 is in INT. position on PC1, and that voltage sensing lead  
is not connected (see Section 4-10).  
Feeder feeds wire, but switches from Be sure PLG5 is in INT. position on PC1. Disconnect voltage sensing clamp from workpiece (see Section  
weld mode to run-in mode while CV 4-10).  
welding with voltage sensing lead  
installed.  
Shieldinggas leak through gas valve in Reduce shielding gas pressure at regulator flowmeter. Do not exceed 50 psi (345 kPa).  
gun.  
OM-1581 Page 37  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
B. Gun Trouble  
Trouble  
Remedy  
No weld output; gun/feeder does not Secure 115 VAC input plug in 115 volts ac receptacle (see Section 4-11).  
work.  
Place Power switch on welding power source in the On position.  
Erratic weld output.  
Tighten and clean all connections.  
ergize weld control; welding wire is not  
energized;shielding gas does not flow.  
Wire does not feed; burnback in contact Reinstall current pick-up tab if applicable (see Section 6-2).  
tip.  
Wire feeds, shielding gas flows, but Clean or replace drive rolls. See Troubleshooting section in welding power source Owner’s Manual (see  
welding wire is not energized.  
Sections 6-2 and 6-3).  
Wire feeds erratically.  
Check and correct drive roll pressure (see Section 4-14).  
Be sure coolant flowrate is at least 1 qt/min (0.95 L/min).  
Gun overheating (water-cooled  
models).  
Corrosion buildup in gun decreasing coolant flowrate. Backflush coolant system, clean coolant system  
filter, and clean fittings (see Section 4-16).  
OM-1581 Page 38  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SECTION 7 ELECTRICAL DIAGRAMS  
156 399-C  
Figure 7-1. Circuit Diagram For Wire Feeder  
OM-1581 Page 39  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
195 712-B  
Figure 7-2. Circuit Diagram For Gun  
OM-1581 Page 40  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Notes  
OM-1581 Page 41  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SECTION 8 PARTS LIST  
. Hardware is common and  
not available unless listed.  
. This main assembly drawing shows the XR-W  
(water-cooled model). Some parts for the XR-A  
(air-cooled model) vary in appearance. When  
differences occur, they are called out in the part  
description.  
143 223-D  
Figure 8-1. Main Assembly  
OM-1581 Page 42  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Item  
No.  
Dia.  
Mkgs.  
Part  
No.  
Description  
Quantity  
Figure 8-1. Main Assembly  
. . 1 . . . . . . . . . . . . . . 089 572 . . Catch, Link-lock . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2  
. . 2 . . . . . . . . . . . . . . . 112 167 . . Insulator, Door . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . 3 . . . . . . . . . . . . . . 134 327 . . Label, Warning General Precautionary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . 4 . . . . . . . . . . . . . +113 569 . . Wrapper . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . 5 . . . . . . . . . . . . . . 126 415 . . Clamp, Saddle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . 6 . . . . . . . . . . . . . . 126 416 . . Handle, Molded . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . 7 . . . . . . . . . . . . . . 058 427 . . Ring, Retaining Spool . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . 8 . . . . . . . . . . . . . . 602 233 . . Washer, Flat Stl .250 Id X .875 Od X .062Thk . . . . . . . . . . . . . . . . . . . . . . . 1  
. . 9 . . . . . . . . . . . . . . 057 543 . . Spring, Cprsn .845 Od X .091 Wire X 1.500 . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . 10 . . . . . . . . . . . . . . . 113 168 . . Washer, Locking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2  
. . 11 . . . . . . . . . . . . . . 058 428 . . Hub, Spool . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . 12 . . . . . . . . . . . . . . 089 561 . . Washer, Anti-turn Stl . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . 13 . . . . . . . . . . . . . . 058 424 . . Washer, Fbr Brake . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . 14 . . . . . . . . . . . . . . 151 697 . . Strip, Brake Surface Anti-turn . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . 15 . . . . . . . . . . . . . . . 112 198 . . Shroud, Spool Wire 12 In . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . 16 . . . . . . . . . . . . . . 030 170 . . Bushing, Snap-in Nyl .750 Id X 1.000Mtg Hole . . . . . . . . . . . . . . . . . . . . . . 1  
. . 17 . . . . . . . . . . . . . . 057 357 . . Bushing, Snap-in Nyl .937 Id X 1.125Mtg Hole (Water-cooled Model) . . . 2  
. . 17 . . . . . . . . . . . . . . 057 357 . . Bushing, Snap-in Nyl .937 Id X 1.125Mtg Hole (Air-cooled Model) . . . . . . 1  
. . 17 . . . . . . . . . . . . . . 070 371 . . Blank, Snap-in Nyl 1.093/1.125Mtg Hole (Air-cooled Model) . . . . . . . . . . . 1  
. . 18 . . . . . . . . . . . . . . 057 358 . . Bushing, Snap-in Nyl 1.000 Id X 1.375Mtg Hole . . . . . . . . . . . . . . . . . . . . . 1  
. . 19 . . . . . . . . . . . . . 134 201 . . Stand-off, PC Card . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4  
. . 20 . . . . PC3 . . . . 114 538 . . Circuit Card, Spot-burnback . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . . . . PLG7,8,11 . 115 094 . . Housing Plug & Sockets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3  
. . . . . . . . PLG9 . . . 115 092 . . Housing Plug & Sockets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . . . . . . PLG10 . . 115 093 . . Housing Plug & Sockets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . 21 . . . . . . . . . . . . . . 073 302 . . Bearing, Ball Rdl Sgl Row .669 X 1.378 X .39 . . . . . . . . . . . . . . . . . . . . . . . 2  
. . 22 . . . . . . . . . . . . . . . 113 161 . . Block, Bearing Front . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . 23 . . . . . . . . . . . . . . . 113 165 . . Stand-off, .250-20 X 1.000 Lg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4  
. . 24 . . . . . . . . . . . . . . 120 396 . . Shaft, Spool . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . 25 . . . . MP1 . . . . . . 113 899 . . Brake, W/Terminals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . 26 . . . . . . . . . . . . . . . 113 900 . . Block, Bearing Rear . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . 27 . . . . . . . . . . . . . . 601 228 . . Clamp, Univ 25A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . 28 . . . . . . . . . . . . . . 601 226 . . Insulator, Vinyl Clamp Univ 25A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . 29 . . . . . . . . . . . . . . 600 848 . . Wire, Lead Mot 12Ga Strd (Order By Ft) . . . . . . . . . . . . . . . . . . . . . . . . . . . 35ft  
. . 30 . . . . . . . . . . . . . . 176 089 . . Tubing, Plstc PVC Black . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1ft  
. . 31 . . . . . . . . . . . . . . . 115 104 . . Connector, Clamp Cable .500 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . 32 . . . . . . . . . . . . . . 000 527 . . Blank, Snap-in Nyl .875Mtg Hole . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . 33 . . . . . . . . . . . . . . 007 826 . . Cable, Port No. 18 3/C (Order By Ft) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11ft  
. . 34 . . . PLG5 . . . . 141 162 . . Housing Plug & Pins . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . 35 . . . . . . . . . . . . . . 079 739 . . Clamp, Cable Strain Relief . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . 36 . . . . . . . . . . . . . . 007 826 . . Cable, Port No 18 3/C (Order By Ft) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11ft  
. . 36 . . . . . . . . . . . ♦♦007 826 . . Cable, Port No. 18 3/C (Order By Ft) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11ft  
. . 37 . . . . . . . . . . . . . . 139 042 . . Bushing, Strain Relief .270/.480 Id X .804Mtg Hole . . . . . . . . . . . . . . . . . . . 2  
. . 37 . . . . . . . . . . . ♦♦139 042 . . Bushing, Strain Relief .270/.480 Id X .804Mtg Hole . . . . . . . . . . . . . . . . . . . 1  
. . 38 . . . . PC1 . . . . . 142 053 . . Circuit Card, Motor Speed Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . . . . . . PLG1 . . . . . 115 092 . . Housing Plug & Sockets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . . . . . . PLG2 . . . . . 115 094 . . Housing Plug & Sockets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . . . . . . PLG3 . . . . . 115 091 . . Housing Plug & Sockets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . . . . . . PLG4 . . . . 131 054 . . Housing Receptacle & Sockets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . 39 . . . . . 2T . . . . . 038 783 . . Block, Term 20A 12P . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . 40 . . . PLG50 . . . 131 203 . . Housing Plug & Pins . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . 41 . PLG51,52 . . 131 204 . . Housing Plug & Sockets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2  
. . 42 . . . . C13 . . . . . . 117 500 . . Capacitor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . 43 . . . . SN1 . . . . . . 110 079 . . Snubber, Polye Mf .5Uf 200VDC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . 44 . . . . . . . . . . . . . . 605 741 . . Clip, Mtg Resistor .312 Id Core . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2  
. . 45 . . . . R35 . . . . . 030 087 . . Resistor, Ww Fxd 25W 200 Ohm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . 46 . . . . . C9 . . . . . . 114 215 . . Capacitor, Polye Film 2.3Uf 250VAC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . 47 . . . . C14 . . . . . 044 602 . . Capacitor, Polye Film .47Uf 400VDC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . 48 . . . . . 4T . . . . . 038 785 . . Strip, Term 3P . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . 49 . . . . . . . . . . . . . . 134 201 . . Stand-off Support, PC Card . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4  
OM-1581 Page 43  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Item  
No.  
Dia.  
Mkgs.  
Part  
No.  
Description  
Quantity  
Figure 8-1. Main Assembly (Continued)  
. . 50 . . . . . . . . . . . . . . . 111 152 . . Skid, Base . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2  
. . 51 . . . . . . . . . . . . . +176 714 . . Cabinet, Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . . . . . . . . . . . . . . . . . 153 901 . . Label, Caution The Recommended Coolant To Be . . . . . . . . . . . . . . . . . . . 1  
. . 52 . . . . . . . . . . . . . . 605 970 . . Washer, Shldr Nyl .310 Od X .252 Id X .064 (Water-cooled Model) . . . . . 4  
. . 52 . . . . . . . . . . . . . . 605 970 . . Washer, Shldr Nyl .310 Od X .252 Id X .064 (Air-cooled Model) . . . . . . . . 3  
. . 53 . . . . . T1 . . . . . 090 465 . . Transformer, Signal 115V 24Vct 4A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . 54 . . . . . . . . . . . . . . 090 439 . . Label, Warning Electric Shock Can Kill . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . 55 . . . . . . . . . . . . . . 089 573 . . Plate, Keeper Link-lock . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2  
. . 56 . . . . . . . . . . . . . . 131 318 . . Insulator, Block Connection (Water-cooled Model) . . . . . . . . . . . . . . . . . . . 1  
. . 56 . . . . . . . . . . . . . . . 113 166 . . Insulator, Term (Air-cooled Model) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . 57 . . . . . . . . . . . . . . . 131 311 . . Block, Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . 58 . . . . . . . . . . . . . . 150 067 . . Fitting, Water Block Extension . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . 59 . . . . . . . . . . . . . . . Fig 8-3 . . Panel, Front W/Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . 60 . . . . . . . . . . . . . . 121 276 . . Bushing, Strain Relief .709 Id X 1.115Mtg Hole . . . . . . . . . . . . . . . . . . . . . . 1  
. . 61 . . . . . . . . . . ♦♦♦134 834 . . Hose, Sae .187 Id X .410 Od (Order By Ft) . . . . . . . . . . . . . . . . . . . . . . . . . 2ft  
. . 62 . . . . . . . . . . ♦♦♦089 120 . . Clamp, Hose .375-.450Clp Dia Slfttng . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4  
. . 63 . . . . . S8 . ♦♦♦164 963 . . Switch, Flow W/Fittings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . 64 . . . . . . . . . . . . . . . 601966 . . Screw, Cap Stl Hexhd .375-16 X 1.250 (Water-cooled Model) . . . . . . . . . 1  
. . 64 . . . . . . . . . . . . . . . 117 498 . . Terminal, Pwr Weld (Air-cooled Model) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . . . . . . . . . . . . . . . . . . 117 496 . . Washer, Fbr .312 Id X .750 Od X .062Thk (Air-cooled Model) . . . . . . . . . . 2  
. . . . . . . . . . . . . . . . . . . 075 150 . . Washer, Shldr Nyl 1.000 Od X .375 Id (Air-cooled Model) . . . . . . . . . . . . . 1  
. . . . . . . . . . . . . . . . . . . 010 910 . . Washer, Flat Stl Sae .375 (Air-cooled Model) . . . . . . . . . . . . . . . . . . . . . . . . 2  
. . . . . . . . . . . . . . . . . . . 601 872 . . Nut, Stl Hex Full .375-16 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2  
. . 65 . . . . . . . . . . . . . . 602 213 . . Washer, Lock Stl Split .375 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . 66 . . . . . . . . . . . . . . 602 243 . . Washer, Flat Stl Std .375 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . 67 . . . . . . . . . . . . . . 151 663 . . Fitting, Plug Water Block . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . 67 . . . . . . . . . . . . . . 151 664 . . Fitting, Diverter Water Block . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . 68 . . . . . . . . . . ♦♦♦151 662 . . Fitting, Pipe Brs Plug Hex .125Npt . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2  
. . 68 . . . . . . . . . . ♦♦♦073 432 . . Fitting, Brs Barbed M 3/16Tbg X 1/8Npt . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2  
. . 69 . . . . . S7 . . . . . . 011 770 . . Switch, Tgl Spdt 5A 125V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . 70 . . . . . . . . . . . . . . . 113 565 . . Door, Rh . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . 71 . . . . . . . . . . . . . . . Fig 8-2 . . Motor & Wire Drive . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . 72 . . . . . . . . . . . . . . 010 546 . . Bushing, Snap-in Nyl .375 Id X .500Mtg Hole . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . 73 . . . REED . . . . 140 786 . . Switch, Reed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . 74 . . . . . . . . . . . . . . 010 493 . . Bushing, Snap-in Nyl .625 Id X .875Mtg Hole . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . 75 . . . . . F1 . . . . . *012 663 . . Fuse, Mintr Gl Slo-blo 3A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . 76 . . . . . . . . . . . . . . 046 432 . . Holder, Fuse Mintr .250 X 1.250 Panel Mtg . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . 77 . . . . . S4 . . . . . . 011 232 . . Switch, Pb Spdt . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . 78 . . . . CB1 . . . . . 174 092 . . Circuit Breaker, Man Reset 1P .7A 250VAC . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . 79 . . . . . 3t . . . . . . 038 861 . . Block, Term 20A 3P . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . . . . . . . . . . . . . . . . . 601 219 . . Link, Jumper Term Blk 20A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . 80 . . . . . . . . . . . . . . . 211 989 . . Fitting, W/Screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
+When ordering a component originally displaying a precautionary label, the label should also be ordered.  
Part of Spot Weld Control Option  
♦♦Part of Voltage Control Option  
♦♦♦Part of Water Flow Shutdown Switch Option  
*Recommended Spare Parts.  
To maintain the factory original performance of your equipment, use only Manufacturer’s Suggested  
Replacement Parts. Model and serial number required when ordering parts from your local distributor.  
OM-1581 Page 44  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Item  
No.  
Dia.  
Mkgs.  
Part  
No.  
Description  
Quantity  
. . . 1 . . . . . . . . . . . . . . 115 191 . . Drive Assembly, Wire (Consisting Of) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 2 . . . . . . . . . . . . . 058 968 . . . . Ring, Retainer E . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 3 . . . . . . . . . . . . . 605 798 . . . . Washer, Shldr Nyl .375 Od X .168 Id X .080Thk . . . . . . . . . . . . . . . . . . . 4  
. . . 4 . . . . . . . . . . . . . 120 395 . . . . Spring, Tension Pressure Roll . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 5 . . . . . . . . . . . . . . 112 713 . . . . Arm, Pressure Roll . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 6 . . . . . . . . . . . . . 058 409 . . . . Bearing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 7 . . . . . . . . . . . . . . 112 887 . . . . Pin, Hinge . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 8 . . . . . . . . . . . . . 057 544 . . . . Spring, Cprsn .240 Od X .026 Wire X 1.000 . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 9 . . . . . . . . . . . . . 120 397 . . . . Nut, Thumb Tension Adjustment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 10 . . . . . . . . . . . . . 147 626 . . . . Cover, Gear Wire Drive . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 11 . . . . . . . . . . . . . 058 549 . . . . Guide, Wire Inlet 1/16 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 12 . . . . . . . . . . . . . 602 306 . . . . Pin, Spring Cs .125 X .500 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2  
. . . 13 . . . . . . . . . . . . . 008 667 . . . . Bearing, Ball Rdl Dbl Row .250 X .687 X .31 . . . . . . . . . . . . . . . . . . . . . . 2  
. . . 14 . . . . . . . . . . . . . . 113 170 . . . . Gear & Shaft, Motor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 15 . . . . . . . . . . . . . 147 624 . . . . Case, Gear Wire Drive . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 16 . . . . . . . . . . . . . 147 625 . . . . Block, Anchor Conduit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 17 . . . . . . . . . . . . . 054 263 . . . . Screw, Thumb Stl .250-20 X .500 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 18 . . . . . . . . . . . . . 120 398 . . . . Roll, Drive V Groove .030-1/16 Wire (Consisting Of) . . . . . . . . . . . . . . . . 1  
. . . 19 . . . . . . . . . . . . . 602 169 . . . . . . Screw, Set Stl Sch 8-32 X .187 Cup Point . . . . . . . . . . . . . . . . . . . . . . . 2  
. . . 20 . . . . . . . . . . . . . 605 971 . . Washer, Shldr Nyl .236 Od X .195 Id X .042Thk . . . . . . . . . . . . . . . . . . . . . 3  
. . . 21 . . . . . . . . . . . . . . 113 162 . . Insulator, Motor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 22 . . . . B1 . . . . . . 113 898 . . Motor, Torque 115VAC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 23 . . . . . . . . . . . . . . 113 169 . . Gear, Driver . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 24 . . . . . . . . . . . . . 604 612 . . Screw, Set Stl Sch 8-32 X .125 Cup Point . . . . . . . . . . . . . . . . . . . . . . . . . . 2  
. Hardware is common and  
not available unless listed.  
2
3
4
3
5
6
7
8
9
1*  
10  
11  
12  
13  
14  
13  
20  
12  
15  
19  
21  
17  
18  
16  
22  
*Includes  
Items 15-19  
24  
23  
114 188-F  
Figure 8-2. Motor & Wire Drive  
To maintain the factory original performance of your equipment, use only Manufacturer’s Suggested  
Replacement Parts. Model and serial number required when ordering parts from your local distributor.  
OM-1581 Page 45  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
. Hardware is common and  
not available unless listed.  
PC2  
11  
See Fig 8-1  
Item 59  
10  
12  
13  
14  
8
9
7
15  
16  
5
4
6
3
2
17  
1
19  
20  
18  
23  
PC4  
22  
21  
145 127-B  
Figure 8-3. Panel, Front w/Components (Water-Cooled Model Illustrated)  
OM-1581 Page 46  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Item  
No.  
Dia.  
Mkgs.  
Part  
No.  
Description  
Quantity  
. . . 1 . . . . . . . . . . . . . . . . 111 569 . . . Meter, Flow 6-60 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 2 . . . . . . . . . . . . . . . . 111 633 . . . Guard, Flow Meter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 3 . . . . . . . . . . . . . . . . 134 834 . . . Hose, Sae .187 Id X .410 Od (Order By Ft) . . . . . . . . . . . . . . . . . . . . . 4ft  
. . . . . . . . . . . . . . . . . . . . . . 056 851 . . . Fitting, Hose Brs Barbed Nipple 3/16Tbg . . . . . . . . . . . . . . . . . . . . . . . 2  
. . . . . . . . . . . . . . . . . . . . . . 010 606 . . . Fitting, Hose Brs Nut .625-18 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2  
. . . . . . . . . . . . . . . . . . . . . . 056 108 . . . Fitting, Hose Brs Ferrule .425 Id X .718 Lg . . . . . . . . . . . . . . . . . . . . . 2  
. . . . . . . . . . . . . . . . . . . . . . 045 852 . . . Clip, Component .687Dia Mtg Adh Back . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 4 . . . . . . . . . . . . . . . . 089 120 . . . Clamp, Hose .375-.450Clp Dia . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2  
. . . 5 . . . . . . . . . . . . . . . . 112 090 . . . Fitting, Pipe Brs Elb 1/8Npt X 3/16 Hose . . . . . . . . . . . . . . . . . . . . . . . 2  
. . . 6 . . . . . . . . . . . . . . . . . . 097 922 . . . Knob, Pointer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 7 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Nameplate, (Order By Model And Serial Number) . . . . . . . . . . . . . . . 1  
. . . 8 . . . . . . . . . . . . . . . . . . 139 678 . . . Fitting, Water (Water-cooled Model) . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 8 . . . . . . . . . . . . . . . . . . 000 527 . . . Blank, Snap-in Nyl .875Mtg Hole (Air-cooled Model) . . . . . . . . . . . . . 1  
. . . 9 . . . . . . . . . . . . . . . . . . 000 434 . . . Fitting, Gas . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 10 . . . . . . . . . . . . . . . ♦♦115 443 . . . Stand-off, No. 6-32 X .750 Lg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2  
. . . 11 . . . . PC2 . . . . . ♦♦139 897 . . . Circuit Card, Meter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . . . . . . . PLG12 . . . . ♦♦115 090 . . . Housing Plug & Pins . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . . . . . . . PLG13 . . . . ♦♦115 094 . . . Housing Receptacle & Sockets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . . . . . . . PLG15 . . . . ♦♦115 092 . . . Housing Plug & Sockets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . . . . . . . PLG16 . . . . ♦♦131 055 . . . Housing Receptacle & Sockets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . . . . . . . . . . . . . . . . . . . . . . 136 339 . . . Cover, Opening Meter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . . . . . . . . . . . . . . . . . . . . . . 120 304 . . . Blank, Snap-in Nyl .250Mtg Hole . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 12 . . . . R44 . . . . . . . . 073 562 . . . Potentiometer, C Sltd Sft 1/T 2W 10K Ohm . . . . . . . . . . . . . . . . . . . . . 1  
. . . 13 . . . . . S2 . . . . . . . . . 120 400 . . . Switch, Tgl 3Pdt Mc 15A 125VAC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 14 . . . R45,46 . . ♦♦♦028 770 . . . Potentiometer, C Sltd Sft 1/T 2W 1 Meg Ohm . . . . . . . . . . . . . . . . . . . 2  
. . . 15 . . . . . S6 . . . . ♦♦♦011 770 . . . Switch, Tgl Spdt 5A 125V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 16 . . . . . S5 . . . . ♦♦♦011 609 . . . Switch, Tgl Spdt 15A 125VAC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 17 . . . . R50 . . ♦♦♦♦035 897 . . . Potentiometer, C Sltd Sft 1/T 2W 1000 Ohm . . . . . . . . . . . . . . . . . . . . 1  
. . . 18 . PC4, RC20 . . . . . 139 508 . . . Circuit Card, Filter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . . . . . . . PLG14 . . . . . . . 115 092 . . . Housing Plug & Sockets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 19 . . . . . . . . . . . . . ♦♦♦097 922 . . . Knob, Pointer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2  
. . . 20 . . . . . . . . . . . . ♦♦♦♦097 922 . . . Knob, Pointer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 21 . . . . . S1 . . . . . . . . . 111 997 . . . Switch, Rocker Spst 10A 250VAC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 22 . . . . . . . . . . . . . . . . . . 057 357 . . . Bushing, Snap-in  
Nyl .937 Id X 1.125Mtg Hole (Water-cooled Model) . . . . . . . . . . . . . . 1  
. . . 22 . . . . . . . . . . . . . . . . . . 070 371 . . . Blank, Snap-in Nyl 1.093/1.125Mtg Hole (Air-cooled Model) . . . . . . . 1  
. . . 23 . . . . . . . . . . . . . . . . . . 030 170 . . . Bushing, Snap-in Nyl .750 Id X 1.000Mtg Hole . . . . . . . . . . . . . . . . . . 1  
Part of Gas Flow Meter Option.  
♦♦Part of Meter Kit Option.  
♦♦♦Part of Spot Weld Control Option.  
♦♦♦♦Part of Voltage Control Option.  
To maintain the factory original performance of your equipment, use only Manufacturer’s Suggested  
Replacement Parts. Model and serial number required when ordering parts from your local distributor.  
OM-1581 Page 47  
Download from Www.Somanuals.com. All Manuals Search And Download.  
. Hardware is common and  
not available unless listed.  
803 706-C  
Figure 8-4. Exploded View Of Gun  
OM-1581 Page 48  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Item  
No.  
Dia.  
Mkgs.  
Part  
No.  
Description  
Quantity  
Figure 8-4. Exploded View Of Gun  
. . 1 . . . . . . . . . . . . . 214 745 . . Cover . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . 2 . . . . . . . . . . . . . Deleted . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
. . 3 . . . . . . . . . . . . . 194 405 . . Conduit W/Fitting, 15ft (15a & W Models) . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . . . . . . . . . . . . . . . . 204 422 . . . . Conduit W/Fitting, Molded 15 Ft . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . . . . . . . . . . . . . . . . 220 879 . . . . Tubing, Nyl .120 Id X .175.180 Od Xroll . . . . . . . . . . . . . . . . . . . . . . . . . . 16ft  
. . . . . . . . . . . . . . . . . . 216 001 . . . . Nut, Liner Collet Retaining . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . . . . . . . . . . . . . . . . 185 106 . . . . Nut, Liner Collet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . 3 . . . . . . . . . . . . . 194 410 . . Conduit W/Fitting, 30ft (30a & W Models) . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . . . . . . . . . . . . . . . . 204 425 . . . . Conduit W/Fitting, Molded 30 Ft . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . . . . . . . . . . . . . . . . 220 879 . . . . Tubing, Nyl .120 Id X .175.180 Od Xroll . . . . . . . . . . . . . . . . . . . . . . . . . . 32ft  
. . . . . . . . . . . . . . . . . . 216 001 . . . . Nut, Liner Collet Retaining . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . . . . . . . . . . . . . . . . 185 106 . . . . Nut, Liner Collet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . 4 . . . . . . . . . . . . . 137 474 . . Hose, Water In (15W Model) (Consisting Of) . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . 4 . . . . . . . . . . . . . 137 475 . . Hose, Water In (30W Model) (Consisting Of) . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . 5 . . . . . . . . . . . . . 137 473 . . Hose, Gas In (15A & W Models) (Consisting Of) . . . . . . . . . . . . . . . . . . . . . . 1  
. . 5 . . . . . . . . . . . . . 137 472 . . Hose, Gas In (30A & W Models) (Consisting Of) . . . . . . . . . . . . . . . . . . . . . . 1  
. . . . . . . . . . . . . . . . . . 056 851 . . . . Fitting, Hose Brs Barbed Nipple 3/16Tbg . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . . . . . . . . . . . . . . . . 010 607 . . . . Fitting, Hose Brs Nut .625-18 Lh (Water Hose) . . . . . . . . . . . . . . . . . . . . . . 1  
. . . . . . . . . . . . . . . . . . 010 606 . . . . Fitting, Hose Brs Nut .625-18Rh (Gas Hose) . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . . . . . . . . . . . . . . . . 056 108 . . . . Fitting, Hose Brs Ferrule .425 Id X .718 Lg . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . . . . . . . . . . . . . . . . 134 834 . . . . Hose, Sae .187 Id X .410 Od (15A & W Models) (Order By Ft) . . . . . . . 16ft  
. . . . . . . . . . . . . . . . . . 134 834 . . . . Hose, Sae .187 Id X .410 Od (30A & W Models) (Order By Ft) . . . . . . . 31ft  
. . . . . . . . . . . . . . . . . . 089 120 . . . . Clamp, Hose .375-.450Clp Dia Slfttng . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . 6 . . . . . . . . . . . . . 000 571 . . Hose, Water (Xr-15 & 30W Models) (Consisting Of) . . . . . . . . . . . . . . . . . . . 2  
. . . . . . . . . . . . . . . . . . 056 851 . . . . Fitting, Hose Brs Barbed Nipple 3/16Tbg . . . . . . . . . . . . . . . . . . . . . . . . . . . 2  
. . . . . . . . . . . . . . . . . . 010 607 . . . . Fitting, Hose Brs Nut .625-18 Lh . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2  
. . . . . . . . . . . . . . . . . . 056 108 . . . . Fitting, Hose Brs Ferrule .425 Id X .718 Lg . . . . . . . . . . . . . . . . . . . . . . . . . 2  
. . . . . . . . . . . . . . . . . . 134 834 . . . . Hose, Sae .187 Id X .410 Od (Order By Ft) . . . . . . . . . . . . . . . . . . . . . . . . 10ft  
. . 7 . . . . . . . . . . . . . 048 837 . . Hose, Gas (Consisting Of) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . . . . . . . . . . . . . . . . 010 603 . . . . Fitting, Hose Brs Barbed Nipple 1/4Tbg . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2  
. . . . . . . . . . . . . . . . . . 010 606 . . . . Fitting, Hose Brs Nut .625-18Rh . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2  
. . . . . . . . . . . . . . . . . . 056 112 . . . . Fitting, Hose Brs Ferrule .475 Id X .718 Lg . . . . . . . . . . . . . . . . . . . . . . . . . 2  
. . . . . . . . . . . . . . . . . . 603 106 . . . . Hose, Nprn Brd No. 1 X .250 Id (Order By Ft) . . . . . . . . . . . . . . . . . . . . . . 10ft  
. . 8 . . . . . . . . . . . . . 198 891 . . Cable, Control 15 Ft (15A & W Models) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . . . . . . PLG20 . . 217 292 . . Housing Plug+Pins, (Service Kit) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . 8 . . . . . . . . . . . . . 198 810 . . Cable, Control 30 Ft (30A & W models) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . . . . . . PLG20 . . 217 292 . . Housing Plug+Pins, (Service Kit) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . 9 . . . . . . . . . . . . . 137 476 . . Cable, Power/Water Out 15Ft (15W Model) . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . 9 . . . . . . . . . . . . . 137 477 . . Cable, Power/Water Out 30Ft (30W Model) . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . 10 . . . . . . . . . . . . 073 476 . . Clamp, Strap Rbr 5 Holes .375 Wide X 4.625 Lg (15A & W Models) . . . . . 6  
. . 10 . . . . . . . . . . . . 073 476 . . Clamp, Strap Rbr 5 Holes .375 Wide X 4.625 Lg (30A & W Models) . . . . . 13  
. . 11 . . . . . . . . . . . . 162 041 . . Bearing Block Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . . . . . . . . . . . . . . . . 604 638 . . Screw, Cap Stl Sch 6-32 X .375 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3  
. . . . . . . . . . . . . . . . . . 143 480 . . Screw, 6-32 X .625 Soc Hd-Hex Stl . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . 12 . . . . . . . . . . . . 136 135 . . Roll, Drive Vk Groove .023-1/16 Wire (Consisting Of) . . . . . . . . . . . . . . . . . . 1  
. . 13 . . . . . . . . . . . . 604 612 . . . . Screw, Set Stl Sch 8-32 X .125 Cup Point . . . . . . . . . . . . . . . . . . . . . . . . . . 2  
. . 14 . . . . . . . . . . . . 114 045 . . Screw, 6-32 X .500 Hexwhd Slt Stl Slffmg . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3  
. . 15 . . . . . . . . . . . . 134 623 . . Bearing, Idler Roll . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . 16 . . . . . . . . . . . . 132 852 . . Arm, Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . 17 . . . . . . . . . . . . 605 798 . . Washer, Shldr Nyl .375 Od X .168 Id X .080 . . . . . . . . . . . . . . . . . . . . . . . . . . 2  
. . 18 . . . . . . . . . . . . 133 083 . . Spring, Tension Adj Drive Roll . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . 19 . . . . . . . . . . . . 144 860 . . Screw, Mach Stl Flh 8-32 X .437 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . 20 . . . . . . . . . . . . 058 968 . . Ring, Retainer E . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . 21 . . . . . . . . . . . . 135 474 . . Pin, Hinge . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . 22 . . . . . . . . . . . . 155 565 . . Screw, Thumb . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . . . . . . . . . . . . . . . . 134 799 . . O-Ring, .176 Id X .070 Cs (Used W/Thumbscrew) . . . . . . . . . . . . . . . . . . . . . 1  
. . 23 . . . . . . . . . . . . 135 126 . . Screw, Set Stl Sch 6-32 X .125 Cup Point . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . 24 . . . . . . . . . . . . 135 580 . . Fitting, Gas . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
OM-1581 Page 49  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Item  
No.  
Dia.  
Mkgs.  
Part  
No.  
Description  
Quantity  
Figure 8-4. Exploded View Of Gun (Continued)  
. . 25 . . . . . . . . . . . . 112 896 . . Spring, Cprsn .240 Od X .020 Wire X .437 . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . 26 . . . . . . . . . . . . 135 773 . . Knob, Thumb Tension Adjusting 8-32 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . 27 . . . . . . . . . . . . 143 360 . . Screw, Mach Stl Rdh 8-32 X .500 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . 28 . . . . . . . . . . . . 136 679 . . Clamp, Strain Relief . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . 29 . . . . . . . . . . . . 132 269 . . Screw, Mach Stl Rdhph 8-32 X .375 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . 30 . . . . . . . . . . . . 214 743 . . Case, Gun Lh/Rh (Molded Halves) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . 31 . . . . . . . . . . . . Deleted . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
. . 32 . . . . . . . . . . . . Deleted . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
. . 33 . . . . . . . . . . . . Deleted . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
. . 34 . . . . B2 . . . . 230 947 . . Motor, Gear Pm 24 VDC 420 RPM 10.2:1 Ratio W/Conn . . . . . . . . . . . . . 1  
. . 35 . . . . . . . . . . . . 602 066 . . Screw, Mach Stl Trh 6-32 X .250 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2  
. . 36 . . . . . . . . . . . . 164 592 . . Trigger . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . 37 . . . . . . . . . . . . 058 262 . . Cap, Valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . 38 . . Fig 8-5 . . 231 531 . . Head Tube Assy, (Air Cooled) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . 38 . . Fig 8-5 . . 231 532 . . Head Tube Assy, (Water Cooled) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . 39 . . . . . . . . . . . . 164 582 . . Housing, Wire Drive (15A & 30A Models) (Includes Items 24 & 37) . . . . . . 1  
. . 39 . . . . . . . . . . . . 164 581 . . Housing, Wire Drive (15W & 30W Models) (Includes Items 24 & 37) . . . . . 1  
. . . . . . . . . . . . . . . . . . 151 661 . . Screw, Set 10-32 X .125 Cup Sch (30W Models Only) . . . . . . . . . . . . . . . . . 2  
. . 40 . . . . . . . . . . . . 133 365 . . Clamp, Head Tube . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . 41 . . . . . . . . . . . . 000 417 . . Screw, Cap Stl Sch 10-24 X 1.000 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2  
. . 42 . . . . . . . . . . . . 203 758 . . Cable, Power (15A Model) (Consisting Of) . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . 42 . . . . . . . . . . . . 203 759 . . Cable, Power (30A Model) (Consisting Of) . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . 43 . . . . . . . . . . . . 133 362 . . Strain Relief, Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . 44 . . . . R4 . . . . 200 096 . . Potentiometer, C Sltd Sft 1/T .5W 10K Ohm . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . 45 . . . . . . . . . . . . 144 861 . . Washer, Anti-turn . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . 46 . . . . . . . . . . . . 135 127 . . Lock, Shaft Pot .250-32 X .125Dia Shaft . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . 47 . . . . . . . . . . . . 602 169 . . Screw, Set Stl Sch 8-32 X .187 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . 48 . . . . . . . . . . . . 134 856 . . Knob, Speed Control 1-10 .140 Shaft X 1.125 Od . . . . . . . . . . . . . . . . . . . . . 1  
. . 49 . . . . . . . . . . . . Deleted . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
. . 50 . . . PB1 . . . . 000 369 . . Switch, Lim 10A 125/250VAC Dpst Plgr . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . 51 . . . . . . . . . . . . 183 884 . . Spring, Cprsn .240 Od X .026 Wire X 1.000 . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . 52 . . . . . . . . . . . . 184 101 . . Washer, Shldr .140 Id X .250 Od . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . 53 . . . . . . . . . . . . 217 934 . . Screw, K40x 20 Pan Hd-trx Stl Pld Pt Thread Forming . . . . . . . . . . . . . . . . . 4  
. . 54 . . . . . . . . . . . . 162 042 . . Contact, Current Pick-Up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . 55 . . . . . . . . . . . . 602 198 . . Washer, Lock .141 Id Stl Split . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4  
. . 56 . . . . . . . . . . . . 134 624 . . Bearing, Flg Nyl .140 Id X .187 Od X .375Flg X .031Thk . . . . . . . . . . . . . . . 2  
To maintain the factory original performance of your equipment, use only Manufacturer’s Suggested  
Replacement Parts. Model and serial number required when ordering parts from your local distributor.  
OM-1581 Page 50  
Download from Www.Somanuals.com. All Manuals Search And Download.  
17  
. Hardware is common and  
not available unless listed.  
8
7
17  
6
5
10  
9
4
3
8
2
16  
1
15  
14  
11  
13  
4
3
2
1
12  
Ref. 800 434-G  
Figure 8-5. Head Tube Assembly Of Pistol-Grip Gun  
Item  
No.  
Part  
No.  
Description  
Quantity  
. . 1 . . . . . . . . . . . . . 199 613 . . Nozzle, Brass 5/8 In Orifice Tapered . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . 2 . . . . . . . . . . . . . . . . . . . . . . . . Tip, Fastip (See Section 9) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . 3 . . . . . . . . . . . . . 227 749 . . Diffuser, .281/.312 Od Collar Fastip 1/8 Rec Edge . . . . . . . . . . . . . . . . . . . . . 1  
. . 4 . . . . . . . . . . . . . 232 284 . . Insulator, Nozzle Collared Diffuser . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . 5 . . . . . . . . . . . . . 219 794 . . Jacket, Outer Insulating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . 6 . . . . . . . . . . . . . 219 795 . . Insulator, Barrel Pistol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . 7 . . . . . . . . . . . . . 219 796 . . Head Tube, Air Pistol (Brazed) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . 8 . . . . . . . . . . . . . 134 800 . . O-ring, .614 Id X .070cs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2  
. . 9 . . . . . . . . . . . . . 203 675 . . Manifold, Water (15w & 30w Models) (Includes) . . . . . . . . . . . . . . . . . . . . . . . 1  
. . 10 . . . . . . . . . . . . 175 946 . . . . O-ring, .614 Id X .070cs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2  
. . 11 . . . . . . . . . . . . 135 128 . . Screw, Cap Stl Sch 6-32 X 1.000 (15, 30w Models) . . . . . . . . . . . . . . . . . . . . 2  
. . 12 . . . . . . . . . . . . 231 532 . . Head Tube Assy, Water Cooled Pistol HD (15, 30w Models) (Includes) . . 1  
. . 13 . . . . . . . . . . . . 220 209 . . . . Jacket, Outer Insulating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . 14 . . . . . . . . . . . . 220 216 . . . . Washer, Flat .594idx1.375odx.125t Black Vulc Fbr . . . . . . . . . . . . . . . . . . . 1  
. . 15 . . . . . . . . . . . . 220 210 . . . . Head Tube, Water Pistol (Brazed) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . 16 . . . . . . . . . . . . 180 966 . . . . O-ring, .926 Id X .070 Cs 70 Duro Quadring . . . . . . . . . . . . . . . . . . . . . . . . 4  
. . 17 . . . . . . . . . . . . 212 156 . . Liner, Phos Bronze .030-1/16 Wire X 7.313 . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
To maintain the factory original performance of your equipment, use only Manufacturer’s Suggested  
Replacement Parts. Model and serial number required when ordering parts from your local distributor.  
OM-1581 Page 51  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
SECTION 9 PARTS LIST INCLUDING CONSUMABLES  
Item  
Number  
1
2
3
4
5
.0301/16” WIRE  
STANDARD  
INSULATOR  
.0301/16” WIRE  
.0351/16” WIRE  
COLLARED  
INSULATOR  
(231 512)  
.0301/16” WIRE  
XR-A Spoolmatic  
Barrel Assy  
(#232 284)  
(227 749)  
(231 511)  
6.0” STRAIGHT  
(#221 087)  
XR-W  
Barrel Assy  
6.0” STRAIGHT  
(#221 519)  
TAPERED  
INSULATOR  
Ref. 803 909-A / 803 932 / 803 933 / 803 934  
Figure 9-1. Consumables Flowchart For XR-A And XR-W Pistol Guns  
OM-1581 Page 52  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Item  
No.  
Part  
No.  
Description  
Quantity  
Table 9-1. Nozzles  
. . . 1 . . . . . . . . . 176238 . . Nozzle, Spot Flat (Requires Diffuser 209099, Used With Any  
Heavy Duty FasTipt Contact Tip) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 1 . . . . . . . . . 176240 . . Nozzle, Spot Inside Corner (Requires Diffuser 209099, Used With Any  
Heavy Duty FasTipt Contact Tip) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 1 . . . . . . . . . 176242 . . Nozzle, Spot Outside Corner (Requires Diffuser 209099, Used With Any  
Heavy Duty FasTipt Contact Tip) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 1 . . . . . . . . 199 610 . . Nozzle, Screw On Brass 1/2 In Orifice . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 1 . . . . . . . . 199 611 . . Nozzle, Screw On Brass 3/4 In Orifice Straight . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 1 . . . . . . . . 199 612 . . Nozzle, Screw On Brass 3/4 In Orifice Straight Heavy Duty . . . . . . . . . . . . . . . 1  
. . . 1 . . . . . . . . 199 613 . . Nozzle, Screw On Brass 5/8 In Orifice . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 1 . . . . . . . . 199 614 . . Nozzle, Screw On Brass 5/8 In Orifice Heavy Duty . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 1 . . . . . . . . 199 615 . . Nozzle, Screw On Copper 1/2 In Orifice . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 1 . . . . . . . . 199 616 . . Nozzle, Screw On Copper 3/4 In Orifice . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 1 . . . . . . . . 199 617 . . Nozzle, Screw On Copper 3/4 In Orifice Heavy Duty . . . . . . . . . . . . . . . . . . . . . 1  
. . . 1 . . . . . . . . . . 198 855 . . Nozzle, Screw On Copper 5/8 In Orifice . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 1 . . . . . . . . . . 199 618 . . Nozzle, Screw On Copper 5/8 In Orifice Heavy Duty . . . . . . . . . . . . . . . . . . . . . 1  
. . . 1 . . . . . . . . 207 313 . . Nozzle, Screw On Copper 5/8 In Orifice 15/16 OD . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 1 . . . . . . . . 209 033 . . Nozzle, Slip On Copper 1/2 In Orifice Tapered (Requires Diffuser 209031 Or  
209032 And Insulator 209047, Used With Any Tapered FasTipt Contact Tip) 1  
. . . 1 . . . . . . . . 209 034 . . Nozzle, Slip On Copper 3/8 In Orifice Tapered (Requires Diffuser 209031 Or  
209032 And Insulator 209047, Used With Any Tapered FasTipt Contact Tip) 1  
. . . 1 . . . . . . . . 209 035 . . Nozzle, Screw On Copper 3/8 In Orifice Tapered (Requires Diffuser 227 747,  
231 511 Or 231 512, Used With Any Tapered FasTipt Contact Tip) . . . . . . . 1  
. . . 1 . . . . . . . . 209 036 . . Nozzle, Screw On Copper 1/2 In Orifice Tapered (Requires Diffuser 227 747,  
231 511 Or 231 512, Used With Any Tapered FasTipt Contact Tip) . . . . . . . 1  
Table 9-2. Heavy Duty FasTiptContact Tips*  
. . . 2 . . . . . . . . 206 185 . . .030 in (0.8 mm) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 2 . . . . . . . . 206 186 . . .035 in (0.9 mm) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 2 . . . . . . . . 206 187 . . .040 in (1.0 mm) or .035 in (0.9 mm) Aluminum Wire . . . . . . . . . . . . . . . . . . . . . 1  
. . . 2 . . . . . . . . . . 206 188 . . .045 in (1.2 mm) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 2 . . . . . . . . 206 189 . . .052 in (1.3 mm) or 3/64 in (1.2 mm) Aluminum Wire . . . . . . . . . . . . . . . . . . . . . 1  
. . . 2 . . . . . . . . . . 206 190 . . 1/16 in (1.6 mm) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 2 . . . . . . . . 206 191 . . .068 in (1.7 mm) or 1/16 in (1.6 mm) Aluminum Wire . . . . . . . . . . . . . . . . . . . . . 1  
Table 9-3. Extra Heavy Duty FasTiptContact Tips*  
. . . 2 . . . . . . . . 199 605 . . .035 in (0.9 mm) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 2 . . . . . . . . 199 606 . . .040 in (1.0 mm) or .035 in (0.9 mm) Aluminum Wire . . . . . . . . . . . . . . . . . . . . . 1  
. . . 2 . . . . . . . . 198 851 . . .045 in (1.2 mm) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 2 . . . . . . . . 198 852 . . .052 in (1.3 mm) or 3/64 in (1.2 mm) Aluminum Wire . . . . . . . . . . . . . . . . . . . . . 1  
. . . 2 . . . . . . . . 198 853 . . 1/16 in (1.6 mm) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 2 . . . . . . . . 198 854 . . .068 in (1.7 mm) or 1/16 in (1.6 mm) Aluminum Wire . . . . . . . . . . . . . . . . . . . . . 1  
Table 9-4. Tapered FasTipt Contact Tips*  
. . . 2 . . . . . . . . . 209025 . . .030 in (0.8 mm) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 2 . . . . . . . . . 209026 . . .035 in (0.9 mm) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 2 . . . . . . . . . 209027 . . .045 in (1.2 mm) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 2 . . . . . . . . . 209028 . . 3/64 in (1.2 mm) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 2 . . . . . . . . . 209029 . . .052 in (1.3 mm) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 2 . . . . . . . . . 209030 . . 1/16 in (1.6 mm) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
OM-1581 Page 53  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Item  
No.  
Part  
No.  
Description  
Quantity  
Figure 9-1. Consumables Flowchart (Continued)  
Table 9-5. Value MultiTurn Contact Tips*  
. . . 2 . . . . . . . . 071 825 . . .030 in (0.9 mm) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 2 . . . . . . . . 054 202 . . .035 in (0.9 mm) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 2 . . . . . . . . 054 201 . . .045 in (1.2 mm) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 2 . . . . . . . . 199 593 . . .3/64 in (1.2 mm) Aluminum Wire . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 2 . . . . . . . . 044 006 . . .052 in (1.3 mm) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 2 . . . . . . . . 047 566 . . 1/16 in (1.6 mm) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 2 . . . . . . . . 202 933 . . 1/16 in (1.6 mm) Aluminum Wire . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
Table 9-6. Gas Diffusers  
. . . 3 . . . . . . . . 198 857 . . 1/8 in Tip Recess For Extra Heavy Duty FasTip Contact Tips . . . . . . . . . . . . 1  
. . . 3 . . . . . . . . 199 623 . . Flush Tip For Extra Heavy Duty FasTip Contact Tips . . . . . . . . . . . . . . . . . . . 1  
. . . 3 . . . . . . . . 199 621 . . 1/8 in Tip Recess For Value Multiturn Contact Tips . . . . . . . . . . . . . . . . . . . . 1  
. . . 3 . . . . . . . . 199 622 . . Flush Tip For Value Multiturn Contact Tips . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 3 . . . . . . . . . . 227 749 . . 1/8 in Tip Recess For Heavy Duty FasTip Contact Tips  
(Standard On All Guns) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 3 . . . . . . . . 231 511 . . 1/4 in Tip Recess For Heavy Duty FasTip Contact Tips . . . . . . . . . . . . . . . . . 1  
. . . 3 . . . . . . . . 231 512 . . Flush Tip For Heavy Duty FasTip Contact Tips . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 3 . . . . . . . . 209 031 . . Slip On Recessed Diffuser (Requires Nozzle 209033 Or 209034  
And Insulator 209047, Used With Any Tapered FasTip Contact Tip) . . . . . . . . 1  
. . . 3 . . . . . . . . 209 032 . . Slip On Flush Diffuser (Requires Nozzle 209033 Or 209034  
And Insulator 209047, Used With Any Tapered FasTip Contact Tip) . . . . . . . . 1  
. . . 3 . . . . . . . . 209 099 . . Spot Diffuser (Requires Spot Nozzle 176238 Or 176240 Or 176242) . . . . . . . 1  
Table 9-7. Insulators  
. . . 4 . . . . . . . . . . 232 284 . . Insulator, Nozzle Collared Diffuser . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 4 . . . . . . . . . . 198 856 . . Insulator, Rubber . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 4 . . . . . . . . . . 209 047 . . Insulator, Teflon (Required When Using Diffuser 209031 Or 209032  
With Nozzle 209033 Or 209034) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
Table 9-8. Barrel Assemblies  
. . . 5 . . . . . . . . . . 221 087 . . Barrel Assy, Air Cooled Pistol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 5 . . . . . . . . . . 221 519 . . Barrel Assy, Water Cooled Pistol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
Table 9-9. Head Tube Assemblies  
. . . . . . . . . . . . . . . . 231 523 . . Kit, Head Tube Assy Air Cooled Pistol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . . . . . . . . . . . . . . 231 524 . . Kit, Head Tube Assy Water Cooled Pistol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
OPTIONAL  
*All contact tips are packaged in bags of 25.  
BE SURE TO PROVIDE MODEL WHEN ORDERING REPLACEMENT PARTS.  
To maintain the factory original performance of your equipment, use only Manufacturer’s Suggested  
Replacement Parts. Model is required when ordering parts from your local distributor.  
OM-1581 Page 54  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Effective January 1, 2007  
(Equipment with a serial number preface of “LH” or newer)  
This limited warranty supersedes all previous Miller warranties and is exclusive with no other  
guarantees or warranties expressed or implied.  
Warranty Questions?  
LIMITED WARRANTY Subject to the terms and conditions  
below, Miller Electric Mfg. Co., Appleton, Wisconsin, warrants to  
its original retail purchaser that new Miller equipment sold after  
the effective date of this limited warranty is free of defects in  
material and workmanship at the time it is shipped by Miller. THIS  
WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER  
WARRANTIES, EXPRESS OR IMPLIED, INCLUDING THE  
WARRANTIES OF MERCHANTABILITY AND FITNESS.  
*
Induction Heating Coils and Blankets, Cables, and  
Non-Electronic Controls  
APT & SAF Model Plasma Cutting Torches  
Remote Controls  
Call  
1-800-4-A-MILLER  
for your local  
Miller distributor.  
*
*
*
*
*
*
Accessory (Kits)  
Replacement Parts (No labor)  
Spoolmate Spoolguns  
Canvas Covers  
Within the warranty periods listed below, Miller will repair or  
replace any warranted parts or components that fail due to such  
defects in material or workmanship. Miller must be notified in  
writing within thirty (30) days of such defect or failure, at which  
time Miller will provide instructions on the warranty claim  
procedures to be followed.  
Your distributor also gives  
you ...  
Miller’s True Blue® Limited Warranty shall not apply to:  
Service  
1. Consumable components; such as contact tips,  
cutting nozzles, contactors, brushes, slip rings, relays  
or parts that fail due to normal wear. (Exception:  
brushes, slip rings, and relays are covered on Bobcat,  
Trailblazer, and Legend models.)  
You always get the fast,  
reliable response you  
need. Most replacement  
parts can be in your  
hands in 24 hours.  
Miller shall honor warranty claims on warranted equipment listed  
below in the event of such a failure within the warranty time  
periods. All warranty time periods start on the delivery date of the  
equipment to the original end-user purchaser, and not to exceed  
one year after the equipment is shipped to a North American  
distributor or eighteen months after the equipment is shipped to  
an International distributor.  
2. Items furnished by Miller, but manufactured by others, such  
as engines or trade accessories. These items are covered  
by the manufacturer’s warranty, if any.  
Support  
Need fast answers to the  
tough welding questions?  
Contact your distributor.  
The expertise of the  
distributor and Miller is  
there to help you, every  
step of the way.  
3. Equipment that has been modified by any party other than  
Miller, or equipment that has been improperly installed,  
improperly operated or misused based upon industry  
standards, or equipment which has not had reasonable and  
necessary maintenance, or equipment which has been  
used for operation outside of the specifications for the  
equipment.  
1. 5 Years Parts — 3 Years Labor  
*
Original main power rectifiers  
2. 3 Years — Parts and Labor  
*
*
*
*
*
*
*
*
Transformer/Rectifier Power Sources  
Plasma Arc Cutting Power Sources  
Process Controllers  
Semi-Automatic and Automatic Wire Feeders  
Inverter Power Sources (Unless Otherwise Stated)  
Water Coolant Systems (Integrated)  
Intellitig  
Engine Driven Welding Generators  
(NOTE: Engines are warranted separately by the  
engine manufacturer.)  
MILLER PRODUCTS ARE INTENDED FOR PURCHASE AND  
USE BY COMMERCIAL/INDUSTRIAL USERS AND PERSONS  
TRAINED AND EXPERIENCED IN THE USE AND  
MAINTENANCE OF WELDING EQUIPMENT.  
In the event of a warranty claim covered by this warranty, the  
exclusive remedies shall be, at Miller’s option: (1) repair; or (2)  
replacement; or, where authorized in writing by Miller in  
appropriate cases, (3) the reasonable cost of repair or  
replacement at an authorized Miller service station; or (4)  
payment of or credit for the purchase price (less reasonable  
depreciation based upon actual use) upon return of the goods at  
customer’s risk and expense. Miller’s option of repair or  
replacement will be F.O.B., Factory at Appleton, Wisconsin, or  
F.O.B. at a Miller authorized service facility as determined by  
Miller. Therefore no compensation or reimbursement for  
transportation costs of any kind will be allowed.  
3. 1 Year — Parts and Labor Unless Specified  
*
Motor Driven Guns (w/exception of Spoolmate  
Spoolguns)  
Positioners and Controllers  
Automatic Motion Devices  
RFCS Foot Controls  
Induction Heating Power Sources, Coolers, and  
Electronic  
Controls/Recorders  
*
*
*
*
TO THE EXTENT PERMITTED BY LAW, THE REMEDIES  
PROVIDED HEREIN ARE THE SOLE AND EXCLUSIVE  
REMEDIES. IN NO EVENT SHALL MILLER BE LIABLE FOR  
DIRECT,  
INDIRECT,  
SPECIAL,  
INCIDENTAL  
OR  
CONSEQUENTIAL DAMAGES (INCLUDING LOSS OF  
PROFIT), WHETHER BASED ON CONTRACT, TORT OR ANY  
OTHER LEGAL THEORY.  
*
*
*
*
*
*
*
*
*
*
Water Coolant Systems (Non-Integrated)  
Flowgauge and Flowmeter Regulators (No Labor)  
HF Units  
ANY EXPRESS WARRANTY NOT PROVIDED HEREIN AND  
Grids  
ANY  
IMPLIED  
WARRANTY,  
GUARANTY  
OR  
REPRESENTATION AS TO PERFORMANCE, AND ANY  
REMEDY FOR BREACH OF CONTRACT TORT OR ANY  
OTHER LEGAL THEORY WHICH, BUT FOR THIS  
PROVISION, MIGHT ARISE BY IMPLICATION, OPERATION  
OF LAW, CUSTOM OF TRADE OR COURSE OF DEALING,  
Spot Welders  
Load Banks  
Arc Stud Power Sources & Arc Stud Guns  
Racks  
Running Gear/Trailers  
Plasma Cutting Torches (except APT & SAF  
Models)  
Field Options  
INCLUDING  
ANY  
IMPLIED  
WARRANTY  
OF  
MERCHANTABILITY OR FITNESS FOR PARTICULAR  
PURPOSE, WITH RESPECT TO ANY AND ALL EQUIPMENT  
FURNISHED BY MILLER IS EXCLUDED AND DISCLAIMED  
BY MILLER.  
*
(NOTE: Field options are covered under True Blue®  
for the remaining warranty period of the product they  
are installed in, or for a minimum of one year —  
whichever is greater.)  
Bernard-Branded Mig Guns (No Labor)  
Weldcraft-Branded TIG Torches (No Labor)  
Subarc Wire Drive Assemblies  
Some states in the U.S.A. do not allow limitations of how long an  
implied warranty lasts, or the exclusion of incidental, indirect,  
special or consequential damages, so the above limitation or  
exclusion may not apply to you. This warranty provides specific  
legal rights, and other rights may be available, but may vary from  
state to state.  
*
*
*
In Canada, legislation in some provinces provides for certain  
additional warranties or remedies other than as stated herein,  
and to the extent that they may not be waived, the limitations and  
exclusions set out above may not apply. This Limited Warranty  
provides specific legal rights, and other rights may be available,  
4. 6 Months — Batteries  
5. 90 Days — Parts  
*
MIG Guns/TIG Torches and Subarc (SAW) Guns  
but may vary from province to province.  
miller_warr 200701  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Owner’s Record  
Please complete and retain with your personal records.  
Model Name  
Purchase Date  
Distributor  
Address  
Serial/Style Number  
(Date which equipment was delivered to original customer.)  
City  
State  
Zip  
For Service  
Contact a DISTRIBUTOR or SERVICE AGENCY near you.  
Always provide Model Name and Serial/Style Number.  
Contact your Distributor for:  
Welding Supplies and Consumables  
Options and Accessories  
Personal Safety Equipment  
Service and Repair  
Miller Electric Mfg. Co.  
An Illinois Tool Works Company  
1635 West Spencer Street  
Appleton, WI 54914 USA  
Replacement Parts  
Training (Schools, Videos, Books)  
International HeadquartersUSA  
USA Phone: 920-735-4505 Auto-Attended  
USA & Canada FAX: 920-735-4134  
International FAX: 920-735-4125  
Technical Manuals (Servicing Information  
and Parts)  
Circuit Diagrams  
European Headquarters −  
United Kingdom  
Phone: 44 (0) 1204-593493  
FAX: 44 (0) 1204-598066  
Welding Process Handbooks  
To locate a Distributor or Service Agency visit  
www.MillerWelds.com  
Contact the Delivering Carrier to:  
File a claim for loss or damage during  
shipment.  
For assistance in filing or settling claims, contact  
your distributor and/or equipment manufacturer’s  
Transportation Department.  
PRINTED IN USA  
© 2007 Miller Electric Mfg. Co.200701  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Miele Dishwasher G 880 User Manual
Multiplex Technology Home Theater Server 3425 User Manual
Nady Systems Microphone 401XQ2HT2LTE4FHE User Manual
NEC Projector VT660 VT560 VT460 User Manual
NeumannBerlin Microphone Condenser Microohone User Manual
Omron Healthcare Blood Pressure Monitor HEM 712CLC User Manual
Oreck Vacuum Cleaner BB877 RD User Manual
Orion Car Audio Car Speaker XTR402 User Manual
Panasonic Cooktop KY B64CA User Manual
Panasonic Printer KX P1121E User Manual