IMPORTANT SAFETY INSTRUCTIONS  
READ AND SAVE THESE INSTRUCTIONS  
This appliance complies with current safety requirements. Improp‐  
er use of the appliance can lead to personal injury and material  
damage.  
Read all instructions before installing or using the appliance for  
the first time. Only use the appliance for its intended purpose.  
Keep these operating instructions in a safe place and pass them  
on to any future user.  
Use  
CAUTION: For General Ventilating Use Only. Do Not Use To Ex‐  
haust Hazardous Or Explosive Materials And Vapors.  
This appliance is intended for residential use only. Use only as de‐  
scribed in these operating instructions.  
This ventilation hood is designed for domestic use and for use in  
similar residential environments.  
This ventilation hood is not intended for outdoor use.  
It must only be used to extract and clean vapors produced during  
cooking. Any other use occurs at the owner's own risk.  
This appliance is suitable for installation above gas or electric  
cooking surfaces.  
Persons who lack physical, sensory or mental abilities, or experi‐  
ence with the appliance should not use it without supervision or in‐  
struction by a responsible person.  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
IMPORTANT SAFETY INSTRUCTIONS  
Children  
As with any appliance, close supervision is necessary when used  
by children.  
Please supervise children in the vicinity of the hood and do not let  
them play with it.  
Danger of suffocation! Ensure that any plastic wrappings, bags,  
etc. are disposed of safely and kept out of the reach of children.  
Technical safety  
WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK,  
OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:  
– Use this appliance only in the manner intended by the manufac‐  
turer. If you have questions, contact Miele.  
– Before servicing or cleaning the appliance, switch power off at  
the service panel and lock the service disconnecting means to  
prevent power from being switched on accidentally. If the service  
disconnecting means cannot be locked, securely fasten a promi‐  
nent warning device, such as a tag, to the service panel.  
Installation, repair and maintenance work should be performed by  
a Miele authorized service technician in accordance with national  
and local safety regulations and the provided installation instruc‐  
tions. Contact Miele’s Technical Service Department for examina‐  
tion, repair or adjustment. Repairs and other work by unauthorized  
persons could be dangerous and may void the warranty.  
A damaged ventilation hood oven can be dangerous. Always  
check for visible signs of damage. Never use a damaged ventilation  
hood.  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
IMPORTANT SAFETY INSTRUCTIONS  
Be certain your appliance is properly installed and grounded by a  
qualified technician. To guarantee the electrical safety of this appli‐  
ance, continuity must exist between the appliance and an effective  
grounding system. It is imperative that this basic safety requirement  
be met. If there is any doubt, have the electrical system of the house  
checked by a qualified electrician.  
To avoid damaging the ventilation hood, make sure that the con‐  
nection data (voltage and frequency) on the data plate correspond to  
the building's power supply before connecting the appliance. When  
in doubt, consult a qualified electrician.  
Do not use a power bar or extension cord to connect the ventila‐  
tion hood to electricity. These are a fire hazard and do not guarantee  
the required level of appliance safety.  
To ensure safe operation, only use the ventilation hood after it has  
been properly installed.  
This ventilation hood may not be used in non-stationary locations  
(e.g. on a ship).  
Only open the housing as described in the enclosed "Installation  
diagram" and in the "Cleaning and care" section of this manual. Un‐  
der no circumstances should any other parts of the housing be  
opened.  
Tampering with electrical connections or components and mechani‐  
cal parts is highly dangerous to the user and can cause operation  
faults.  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
IMPORTANT SAFETY INSTRUCTIONS  
Defective components should be replaced by Miele original parts  
only. Only with these parts can the manufacturer guarantee the safe‐  
ty of the appliance.  
During installation, maintenance, and repair work, the ventilation  
hood must be disconnected from the electrical supply. It is only  
completely isolated from the electricity supply if one of the following  
applies:  
– The circuit breakers on the electrical service panel are tripped.  
– The screw-type fuses on the electrical service panel have been  
removed.  
– The power cable (if present) has been unplugged from the socket  
(pull the plug not the cord).  
Proper use  
WARNING: TO REDUCE THE RISK OF A COOKTOP GREASE  
FIRE:  
– a) Never leave surface units unattended at high settings. Boil‐  
overs cause smoking and greasy spillovers may ignite. Heat oils  
slowly on low or medium settings.  
– b) Always turn the hood on when cooking at a high heat.  
– c) Clean the ventilation hood frequently. Grease should not be al‐  
lowed to accumulate on the fan or filter.  
– d) Use the proper pan size. Always use cookware appropriate for  
the size of the cooking area.  
Never use an open flame beneath the ventilation hood.  
To avoid the risk of fire, do not flambé or grill over an open flame.  
When turned on, the ventilation hood will draw any flames into the  
filter. Fat deposits may ignite.  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
IMPORTANT SAFETY INSTRUCTIONS  
WARNING: TO REDUCE THE RISK OF INJURY TO PERSONS IN  
THE EVENT OF A COOKTOP GREASE FIRE, OBSERVE THE FOL‐  
LOWING*:  
– a) SMOTHER FLAMES with a close fitting lid, cookie sheet, or  
metal tray then turn off the burner. BE CAREFUL TO PREVENT  
BURNS. If the flames do not go out immediately, EVACUATE AND  
CALL THE FIRE DEPARTMENT.  
– b) NEVER PICK UP A FLAMING PAN - You may be burned.  
– c) DO NOT USE WATER, including wet dishcloths or towels - a vi‐  
olent steam explosion will result.  
– d) Use a fire extinguisher ONLY if:  
– 1) You have a class ABC extinguisher, and you know how to operate it.  
– 2) The fire is small and contained in the area where it started.  
– 3) The fire department is being called.  
– 4) You can fight the fire with your back to an exit.  
*Based on "Kitchen Firesafety Tips" published by NFPA.  
The ventilation hood may become damaged if exposed to exces‐  
sive heat from a gas cooktop.  
– When using the ventilation hood over a gas cooktop, ensure that  
any burners in use are always covered by cookware. Turn burners  
off when removing the cookware, even if doing so for just a short  
time.  
– Select cookware that is suitable for the size of the burner.  
– Adjust the flame so that it never extends up the sides of the cook‐  
ware.  
– Avoid overheating the cookware (e.g., when cooking with a wok).  
Always turn the ventilation hood on whenever a burner is in use to  
prevent damage from condensation.  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
IMPORTANT SAFETY INSTRUCTIONS  
Overheated oils and fats can ignite and set the ventilation hood  
on fire.  
When cooking with oils or fats, do not leave pots, pans or fryers un‐  
attended. Never leave an electric grill unattended when grilling.  
Fat and debris deposits impair the proper functioning of the venti‐  
lation hood.  
To ensure that cooking vapors are properly cleaned, never use the  
ventilation hood without the grease filters in place.  
A filter containing too much grease is a fire hazard!  
The filters should be cleaned or replaced at regular intervals.  
Please note that the heat rising from the stovetop during cooking  
can cause the ventilation hood to become very hot.  
Do not touch the housing or the grease filters until the ventilation  
hood has cooled down.  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
IMPORTANT SAFETY INSTRUCTIONS  
Proper installation  
WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK,  
OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:  
– a) Installation work and electrical wiring must be done by quali‐  
fied person(s) in accordance with all applicable codes and stand‐  
ards, including fire-rated construction.  
– b) Sufficient air is needed for combustion and exhausting of gas‐  
es through the flue (chimney of fuel burning equipment to prevent  
back drafting. Follow the heating equipment manufacturer’s  
guideline and safety standards such as those published by the  
National Fire Protection Association (NFPA) and the American So‐  
ciety for Heating, Refrigeration and Air Conditioning Engineers  
(ASHRAE), and the local code authorities.  
– c) When cutting or drilling into the wall or ceiling, do not damage  
electrical wiring and other hidden utilities.  
– d) Ducted hoods must always be vented to the outdoors.  
– e) Do not use this hood with any solid-state speed control device.  
To determine whether a ventilation hood may be operated above  
your cooking appliance, please refer to the information provided by  
the appliance's manufacturer.  
Safety regulations prohibit the installation of a ventilation hood  
above solid fuel stoves.  
Insufficient distance between the cooking appliance and the ven‐  
tilation hood can result in damage to the hood.  
The minimum safety distances between the appliance and the bot‐  
tom of the ventilation hood specified in the "Installation" section  
must be maintained, unless the appliance's manufacturer has indi‐  
cated that a greater distance is required.  
If more than one cooking appliance is used beneath the ventilation  
hood, and if different minimum safety distances apply for these ap‐  
pliances, you should use the greater distance.  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
IMPORTANT SAFETY INSTRUCTIONS  
Be sure to observe the information contained in the "Installation"  
section when mounting the ventilation hood.  
Metal parts can have sharp edges which may cause injury.  
Wear gloves to protect your hands from being cut.  
When installing the exhaust duct, only use pipes or tubes made of  
non-flammable material. These can be obtained from your Miele  
dealer or from Miele Technical Service.  
Exhaust air should not be vented into a chimney or vent flue  
which is otherwise in use and should not be channeled into ducting  
which ventilates rooms with fuel-burning installations.  
If exhaust air is to be extracted into a chimney or vent flue no lon‐  
ger used for other purposes, be sure to comply with all applicable  
regulations.  
WARNING: TO REDUCE THE RISK OF FIRE USE ONLY METAL  
DUCTWORK.  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
IMPORTANT SAFETY INSTRUCTIONS  
Cleaning and care  
Never use a steam cleaner to clean the ventilation hood.  
The steam can reach the electrical components and cause a short  
circuit.  
Accessories  
Use only genuine original Miele parts. If parts or accessories from  
other manufacturers are used, the warranty will become void.  
FCC Declaration of Conformity  
These devices comply with FCC Rules Part 15. This equipment  
has been tested and found to be in compliance with the limits for a  
Class B digital device, pursuant to Part 15 of the FCC Rules of Oper‐  
ation and is subject to the following conditions:  
These devices may not cause harmful interference.  
These devices must accept any interference received, including in‐  
terference that may cause undesired operation.  
FCC Radiation Exposure Statement  
This equipment complies with FCC radiation exposure limits set  
forth for an uncontrolled environment. This equipment should be in‐  
stalled and operated with minimum distance 8" (20 cm) between the  
radiator and your body.  
Industry Canada Statement  
This digital apparatus does not exceed the Class B limits for Ra‐  
dio Noise Emissions from digital apparatus set out in the Radio In‐  
terference Regulations of the Canadian Department of Communica‐  
tions.  
Complies with Canadian ICES-003 Class B specifications.  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Caring for the environment  
Disposal of the packing mate‐  
rial  
The cardboard box and packing materi‐  
als protect the appliance during ship‐  
ping. They have been designed to be  
biodegradable and recyclable.  
Disposal of your old appliance  
Do not dispose of this appliance with  
your household waste.  
Old appliances may contain materials  
that can be recycled. Please contact  
your local recycling authority about the  
possibility of recycling these materials.  
Ensure that any plastic wrappings,  
bags, etc. are disposed of safely and  
kept out of the reach of children. Dan‐  
ger of suffocation!  
Before discarding an old appliance en‐  
sure that it presents no danger to chil‐  
dren while being stored for disposal.  
Unplug it from the outlet, cut off its  
power cord and remove any doors to  
prevent hazards.  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Description of functions  
The following functions are available on  
your ventilation hood, depending on the  
model:  
Recirculation mode  
The recirculation mode requires a recir‐  
culation kit and OdorFree Charcoal Fil‐  
ter (available as optional accessories,  
see "Technical Data" for more informa‐  
tion)  
Vented mode  
The air is drawn in and cleaned by the  
grease filters and directed outside.  
The air is drawn in and first cleaned by  
the grease filters and then by an Odor‐  
Free Charcoal Filter. The cleaned air is  
then recirculated back into the kitchen.  
Non-return flap  
A non-return flap in the ducting pre‐  
vents the exchange of inside and out‐  
side air from occurring when the venti‐  
lation hood is not in use.  
The flap is closed when the ventilation  
hood is turned off.  
When the ventilation hood is turned on,  
the non-return flap opens so that the  
exhaust air can be transported outside  
without any obstruction.  
A non-return flap has been provided  
with the hood in case your ducting  
does not have one. It is inserted into  
the outlet duct collar of the fan.  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Description of functions  
The cooktop transmits information  
about its operational status to the hood  
using a radio signal.  
Con@ctivity 2.0 function  
Automatic control  
This hood features a communication  
function which enables the automatic  
control of the hood based on the opera‐  
tional status of a Miele cooktop.  
– When a burner is turned on, the  
cooktop lighting on the hood turns  
on automatically. After a brief delay,  
the ventilation hood fan also comes  
on.  
– During cooking, the hood automati‐  
cally selects the fan level based on  
the number of burners in operation  
and their power levels.  
– Once you have turned off the cook‐  
top, the fan and the lighting will turn  
off automatically after a predeter‐  
mined delay.  
Detailed information about this function  
can be found under "Operation."  
To enable the communication function,  
the cooktop must be equipped with the  
corresponding Con@ctivity 2.0 stick .  
Please refer to the installation instruc‐  
tions for the Con@ctivity 2.0 stick to  
determine whether connection to your  
cooktop is possible.  
There must be radio contact between  
the cooktop and the hood for you to be  
able to use the Con@ctivity 2.0 function  
(see "Activating Con@ctivity 2.0").  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Guide to the appliance  
16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Guide to the appliance  
a
b
c
d
Chimney extension  
Chimney  
Canopy  
Control panel  
The symbols act as sensor-controlled buttons. To select a function, tap the  
button. An audible tone sounds briefly to confirm selection.  
e
f
Grease filter  
Spacer frame  
The spacer frame creates a shadow gap between the chimney and the ceiling.  
The hood can be installed with or without the spacer frame.  
g
Recirculation vent  
(only for recirculation mode)  
h
i
Overhead lighting  
OdorFree Charcoal Filter  
Optional accessory for recirculation mode  
j
k
l
m
n
o
Turns the fan on and off  
Overhead light button  
Fan power selection  
Delayed shut-down button  
Filter saturation indicator for the grease filters  
Filter saturation indicator for the OdorFree Charcoal Filter  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Operation (Automatic mode)  
When Con@ctivity 2.0 is active, the  
hood always operates in Automatic  
mode (see "Activating Con@ctivity  
2.0").  
Reaction time  
Changing the power setting on the  
cooktop does not lead to an immediate  
increase or decrease in cooking vapors.  
For this reason, the hood reacts with a  
slight delay.  
See "Cooking without Con@ctivity 2.0"  
for information on manually operating  
the hood.  
Delays can also result from the fact that  
the cooktop transmits the information  
to the hood in intervals.  
Cooking with Con@ctivity 2.0  
(Automatic mode)  
Turn on a burner to the desired power  
setting.  
The reaction time can vary from a few  
seconds to a couple of minutes.  
The hood lighting will come on.  
After a few seconds, the fan will come  
on, briefly operating at power level 2  
before immediately switching to level 1.  
The hood selects the fan level automat‐  
ically during cooking.  
This level is determined by the total  
output of the cooktop, i.e. the number  
of burners in operation and the power  
settings selected.  
If you select a higher power setting  
on the cooktop or switch on multiple  
burners, the hood will switch to a  
higher fan level.  
If you select a lower power setting on  
the cooktop or turn off a burner, the  
hood will accordingly switch to a low‐  
er fan level.  
Examples for fan levels 1 to 4  
18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Operation (Automatic mode)  
Cooking process  
Turning off  
If, for example, you switch on a burn‐ Turn off all burners.  
er at the highest power setting to  
Over the next few minutes, the ventila‐  
heat cookware in preparation for  
searing and then reduce the power  
level after approx. 60 to 90 seconds*,  
a cooking process is recognized.  
tion hood fan setting will decrease one  
level at a time until the hood eventually  
turns off.  
This helps to neutralize any lingering  
vapors and odors in the air.  
The hood turns on automatically and,  
after the cooktop power level has been  
reduced, switches back to fan level 3,  
where it remains for approx. 5 minutes.  
– From the intensive setting IS, the fan  
immediately switches to level 3.  
After this, the fan level is once again  
determined by the Con@ctivity function.  
– If the fan is operating at level 3, it will  
switch to level 2 after approx. 1 mi‐  
nute.  
You can also manually select a differ‐  
ent fan level before then.  
– From level 2, the fan switches to level  
1 after 2 minutes.  
– After 2 minutes at level 1, the fan au‐  
tomatically turns off.  
– After another 30 seconds, the lighting  
turns off.  
The cooking process is now finished.  
19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Operation (Automatic mode)  
Temporarily exiting Automatic  
mode  
To temporarily exit the Automatic mode  
when cooking:  
Resuming Automatic mode  
The ventilation hood resumes Automat‐  
ic mode:  
If the ventilation hood has not been  
used for a period of approx. 5 mi‐  
nutes after the manual selection of a  
fan level, or  
Manually select a different fan level,  
or  
Manually turn the hood off, or  
If the manually selected fan level  
once again matches the automatic  
setting, or  
Activate the Delayed shut down func‐  
tion on the ventilation hood. The  
fan turns off after the delay time se‐  
lected, and the lighting will remain on.  
If the ventilation hood fan and the  
cooktop have been turned off for at  
least 30 seconds.  
Automatic mode will resume the next  
time the cooktop is turned on.  
The ventilation hood functions can now  
be operated manually (see "Cooking  
without Con@ctivity 2.0").  
If you wish to manually operate the  
ventilation hood for a complete cook‐  
ing process, turn on the ventilation  
hood fan before turning on the cook‐  
top.  
If the ventilation hood and the cook‐  
top have been turned off for at least  
30 seconds after you have finished  
cooking, Automatic mode will resume  
the next time the cooktop is turned  
on.  
20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Operation (Manual mode)  
Cooking without Con@ctivity  
2.0 (Manual mode)  
Selecting the delayed shut  
down time  
The hood can be operated manually if:  
It is a good idea to let the fan run for a  
few more minutes after cooking in order  
to neutralize any lingering vapors and  
odors in the air.  
– The Con@ctivity 2.0 function is not  
activated.  
You have temporarily deactivated the With the delayed shut down function, it  
Con@ctivity 2.0 function (see "Tem‐  
porarily exiting Automatic mode").  
is possible to have the fan automatically  
shut off after a predetermined period of  
time.  
Turning on the fan  
Tap the On/Off button .  
After you have finished cooking, tap  
the delayed shut down button .  
The fan switches to level 2.  
– Once: fan switches off after 5 mi‐  
nutes (5 lights up).  
Selecting the power level  
Power levels 1 to 3 can be used for light  
to heavy cooking vapors and odors.  
Twice: fan switches off after 15 mi‐  
nutes (15 lights up).  
– If you press the delayed shut down  
button again, the fan remains  
turned on (5 15 goes out).  
For strong vapors and odors that are  
temporarily produced when cooking,  
e.g., during searing, select the IS inten‐  
sive level.  
Turning off the fan  
Press the On/Off button to turn the  
fan off.  
Select the power level required by  
tapping a button from 1 to IS.  
Reducing power of the intensive set‐  
ting  
If power management is activated (de‐  
fault setting), the fan automatically  
switches back to level 3 after 5 mi‐  
nutes.  
21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
Operation (Manual mode)  
Tap 1 to turn off the power manage‐  
Turning overhead lighting  
on/off  
The overhead lighting can be turned on  
and off separately from the fan.  
ment.  
The 1 and IS indicators will flash.  
Touch IS to turn it on.  
Tap the lighting button .  
The 1 and IS indicators are constantly  
lit.  
Power management  
Confirm the setting by pressing the  
delayed shut down button .  
The ventilation hood features a power  
management system for switching off  
the lighting and reducing the fan power  
setting automatically.  
All the indicator lights will go out.  
If the setting is not confirmed within 4  
minutes, the hood automatically reverts  
to the old setting.  
– If the intensive setting is selected, the  
fan automatically switches to level 3  
after 5 minutes.  
– If the fan is set to level 3, 2 or 1, it  
switches to the next-highest fan set‐  
ting after 2 hours and then in 30-mi‐  
nute intervals until the fan eventually  
switches off.  
– If the cooktop lighting is on, it auto‐  
matically turns off after 12 hours.  
Turning power management on/off  
Turn off the fan and the lighting.  
Press the delayed shut down button  
for approx. 10 seconds until 1  
lights up in the fan power display.  
Next, tap the following buttons in  
succession:  
– The lighting button ,  
– Followed by the 1 button and then  
– The lighting button again.  
If power management is turned on, the  
1 and IS indicators will be continuously  
lit.  
If it is switched off, 1 and IS will flash.  
22  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Operation (Automatic and Manual modes)  
The indicators 1 to IS show the current  
time setting:  
Filter saturation indicator  
The number of hours the hood has  
been in operation is stored in appliance  
memory.  
Indicator 1 ............................... 20 hours  
Indicator 2................................ 30 hours  
Indicator 3................................ 40 hours  
Indicator IS .............................. 50 hours  
The filter saturation indicators show  
when the filters need to be cleaned or  
changed by lighting up the grease filter  
symbol or OdorFree Charcoal Filter  
symbol . Additional information on  
cleaning and changing the filters and  
resetting the filter saturation counters  
can be found under "Cleaning and  
care."  
Tap the relevant button to select the  
time required.  
Confirm your choice by touching the  
grease filter button .  
All the indicator lights will go out.  
Adjusting the filter saturation indica‐  
tor for the grease filter  
If the setting is not confirmed within 4  
minutes, the hood automatically reverts  
to the old setting.  
You can set the filter saturation indica‐  
tor to suit your cooking habits.  
The factory default setting is a cleaning  
interval of 30 hours.  
– Select a shorter time (20 hours) if you  
often fry foods.  
– We also recommend a shorter clean‐  
ing interval if you only cook occa‐  
sionally. This will prevent grease  
buildup from hardening and making  
cleaning more difficult.  
– Select a longer cleaning interval of 40  
or 50 hours if you use very little fat  
when cooking.  
Press the On/Off button to turn off  
the fan.  
Tap the delayed shut down button   
and the grease filter button at the  
same time.  
The grease filter symbol and one of  
the fan power level indicators will flash.  
23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Operation (Automatic and Manual modes)  
Activating/changing the OdorFree  
Charcoal Filter operating hours  
counter  
Checking the filter saturation indica‐  
tor  
Before the set operating time has run  
The OdorFree Charcoal Filter is required out, you can check what percentage of  
for extraction mode.  
the time has elapsed.  
The operating hours counter for the  
OdorFree Charcoal Filter requires one-  
time activation and must be set to  
match your cooking habits.  
Press the On/Off button to turn the  
fan on.  
Press and hold the grease filter but‐  
ton or the OdorFree Charcoal Fil‐  
ter button .  
Press the On/Off button to turn the  
fan off.  
One or more of the power level indica‐  
tors will flash.  
Tap the delayed shut-down button   
and the OdorFree Charcoal Filter but‐  
ton at the same time.  
The number of flashing indicators  
shows the elapsed operating hours as a  
The OdorFree Charcoal Filter symbol percentage.  
and one of the fan setting indicators will  
flash.  
Indicator 1 ..................................... 25%  
Indicators 1 and 2 ......................... 50%  
The indicators 1 to IS show the current  
time setting:  
Indicators 1 to 3 ............................ 75%  
Indicator 1 ............................. 120 hours Indicators 1 to IS ......................... 100%  
Indicator 2.............................. 180 hours  
Indicator 3 ............................. 240 hours  
Indicator IS.......................... deactivated  
The elapsed operating hours remain  
stored in the memory when the hood  
is turned off or if power to the appli‐  
ance is lost.  
Tap the relevant button to select the  
time required.  
Confirm your choice by tapping the  
OdorFree Charcoal Filter button .  
All the indicator lights go out.  
If the setting is not confirmed within 4  
minutes, the old setting is retained.  
24  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Operation (Automatic and Manual modes)  
Sensor button signal tone  
Whenever you select a feature with the  
sensor buttons, you will hear a brief sig‐  
nal tone.  
You can deactivate this signal tone if  
you prefer.  
Press the On/Off button to turn the  
fan off.  
Tap the IS and the grease filter   
buttons at the same time for approx.  
5 seconds until a short signal tone is  
heard.  
The signal tone is now turned off for all  
functions.  
To reactivate the signal tone, follow  
the same steps.  
If the hood is disconnected from the  
power supply, or after a power inter‐  
ruption, the beep is automatically re‐  
activated, regardless of the previous  
settings.  
25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Cleaning and care  
Special instructions for stainless  
steel surfaces  
WARNING: TO REDUCE THE RISK  
OF FIRE, ELECTRIC SHOCK, OR IN‐  
JURY TO PERSONS, OBSERVE THE  
FOLLOWING:  
(does not apply to control buttons)  
Stainless steel surfaces can also be  
cleaned using a non-abrasive stain‐  
less steel cleaner, available from  
Miele.  
Before cleaning or servicing the  
hood, disconnect it from the power  
supply, see "IMPORTANT SAFETY  
INSTRUCTIONS".  
To prevent the surfaces from quickly  
becoming dirty again, we recom‐  
mend treating them with a stainless  
steel care conditioner.  
Apply sparingly over the entire area  
using a soft cloth.  
Stainless steel housing  
General  
The surfaces and control buttons are  
susceptible to scratching and chip‐  
ping.  
Observe the following cleaning in‐  
structions.  
Special instructions for RAL color  
finish housing  
(special order)  
Observe the general cleaning instruc‐  
Clean all surfaces and control but‐  
tons using warm water and liquid  
dish soap only, applying the mixture  
with a sponge cloth.  
tions contained in this chapter.  
Minor scratches on the surface are in‐  
evitable when cleaning the housing.  
Depending on the lighting in the kitch‐  
en, this may negatively affect the ap‐  
pliance's appearance.  
Make sure that no water gets into  
the interior of the hood.  
Only use a damp cloth to clean the  
hood, especially in the control panel  
area.  
After cleaning, dry the surfaces with a  
soft cloth.  
Avoid the following:  
– Cleaners containing soda, acid or  
chloride, or cleaners containing sol‐  
vents  
– Abrasive cleaners such as scouring  
powder, scouring liquid, abrasive  
sponges such as pot scourers, or  
used sponges that still contain resi‐  
dues from abrasive cleaners  
26  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Cleaning and care  
Special instructions for control but‐  
tons  
You can adjust the interval of the filter  
saturation counter to match your  
cooking habits (see "Operation").  
Do not leave dirt and debris on the  
buttons for any length of time.  
Otherwise they may become discol‐  
ored or damaged.  
Remove any dirt or debris immedi‐  
ately.  
Removing the grease filters  
When handling a grease filter, be  
careful not to drop it.  
This can result in damage to the filter  
and to the cooktop.  
Make sure you hold the filter secure‐  
ly at all times when handling it.  
Observe the general cleaning instruc‐  
tions contained in this chapter.  
Do not use a stainless steel cleaner  
to clean the control buttons.  
Special instructions for glass surfa‐  
ces  
Glass surfaces can be cleaned using  
a commercial glass cleaner.  
Grease filters  
The reusable metal grease filters in the  
appliance remove the solid particles  
contained in kitchen vapors (fat, dust,  
etc.), thereby preventing the ventilation  
hood from becoming dirty.  
A dirty filter is a fire hazard!  
Cleaning intervals  
Over longer periods of time, fat buildup  
on the grease filter hardens and makes  
cleaning more difficult. Therefore, we  
recommend cleaning the grease filters  
once every 3-4 weeks.  
By illuminating the grease filter symbol,  
the filter saturation counter reminds  
you to regularly clean the grease filters.  
27  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Cleaning and care  
Cleaning the grease filters in the  
dishwasher  
Place the filters as upright or inclined  
as possible in the lower basket. En‐  
sure that the spray arm is not ob‐  
structed.  
Use a common household dishwash‐  
er detergent.  
Select a program with a wash tem‐  
perature between 122°F (50°C) and  
149°F (65°C). In a Miele dishwasher  
use the "Normal" program.  
To remove a grease filter, release the  
locking clip. Then, open the filter to a  
45° angle, unhook it, and remove it  
from the hood.  
Depending on the detergent used,  
cleaning the filters in a dishwasher  
may cause the inside filter surfaces to  
become discolored. However, this will  
not affect the functioning of the filters  
in any way.  
Cleaning the grease filters by hand  
Clean the filters with a soft nylon  
brush in a mild solution of hot water  
and dish soap. Do not use undiluted  
dish soap.  
After cleaning  
Unsuitable cleaning agents  
After cleaning, leave the filters on an  
Unsuitable cleaners can cause damage  
to the filter surfaces if used regularly.  
Do not use any of the following:  
absorbent surface to dry.  
When removing the filters for clean‐  
ing, also clean off any accessible oil  
or fat buildup from the housing. Do‐  
ing so will prevent a fire hazard.  
– Lime removers  
– Abrasive powders or abrasive liquids  
– Aggressive all-purpose cleaners and  
degreaser sprays  
Reinstall the grease filters. When in‐  
serting the filters, make sure that the  
locking clip is facing down.  
– Oven sprays  
28  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Cleaning and care  
If the filters have been installed incor‐  
rectly, you can insert a small screw‐  
driver into the slit to disengage the  
locking clip.  
OdorFree Charcoal Filter  
If the hood is equipped for recirculation,  
an OdorFree Charcoal Filter must be in‐  
stalled in addition to the grease filters.  
This filter is designed to absorb odor-  
causing agents and is mounted in the  
canopy above the grease filters.  
Resetting the filter saturation indica‐  
tor for the grease filter  
Once cleaning is complete, the filter  
saturation indicator must be reset.  
OdorFree Charcoal Filters are available  
from your Miele dealer or from Miele.  
See "Technical data" for the type and  
reference number.  
While the fan is turned on, press the  
grease filter button for approx. 3  
seconds, until only the 1 is flashing.  
Installing/replacing the OdorFree  
Charcoal Filter  
The grease filter symbol goes out.  
When cleaning the grease filters before  
the full operating time has elapsed:  
To install or replace the OdorFree  
Charcoal Filter, the grease filters must  
first be removed as described above.  
Press the grease filter button for  
approx. 6 seconds, until only the 1 is  
flashing.  
Remove the OdorFree Charcoal Filter  
from its packaging.  
Press the OdorFree Charcoal Filter in‐  
to the frame.  
Reinstall the grease filters.  
When installing the filter for the first  
time, activate the filter saturation  
counter (see "Operation").  
29  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Cleaning and care  
When to change the OdorFree Char‐  
coal Filter  
Always replace the OdorFree Char‐  
coal Filter whenever it no longer ab‐  
sorbs kitchen odors effectively.  
Replace the filter at least once every  
6 months.  
The OdorFree Charcoal Filter saturation  
counter will light up to remind you to  
change the charcoal filter regularly.  
The OdorFree Charcoal Filter satura‐  
tion counter requires one-time activa‐  
tion before use (see the "Operation"  
chapter).  
Resetting the operating hours coun‐  
ter for the OdorFree Charcoal Filter  
If the operating hours counter is activat‐  
ed, it must be reset each time the filter  
is changed.  
Press the OdorFree Charcoal Filter  
button for approx. 3 seconds with  
the ventilation hood switched on until  
only the indicator light for level 1 is  
flashing.  
The OdorFree Charcoal Filter symbol   
will go out.  
If you replace the OdorFree Charcoal  
Filter before the full operating time  
elapses:  
Press the OdorFree Charcoal Filter  
button for approx. 6 seconds until  
only the indicator light for level 1 is  
flashing.  
Disposing of the OdorFree Charcoal  
Filter  
Used OdorFree Charcoal Filters can  
be disposed of with normal house‐  
hold waste.  
30  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Installation  
Before installation  
Before installing the appliance,  
read all of the information contained  
in this chapter and also in the "IM‐  
PORTANT SAFETY INSTRUCTIONS"  
section.  
4 extension piece holders  
for aligning and securing the telescopic  
chimney  
Installation parts  
4 screws M3/16" x 5/16"  
(M4 x 8.5 mm)  
for securing the extension piece hold‐  
ers.  
4 screws, 6 9/16" x 4 5/16"  
(7 x 110 mm) and  
14 screws M3/16" x 5/16"  
(M4 x 8 mm)  
for securing the spacer frame and se‐  
curing the hood to the installation  
frame.  
4 plugs, 3/8" x 3 1/8" (10 x 80 mm)  
for securing the ventilation hood to the  
ceiling (not for use in USA / CDN).  
The screws and plugs are designed  
for use in solid ceilings only.  
Use different fasteners for other ceil‐  
ing construction types. Make sure  
that the ceiling can support the load.  
1 screw M3/16" x 5/8" (M4 x 16 mm)  
for securing the chimney.  
DUI 32 recirculation kit for recircula‐  
tion mode  
(not supplied, available as an optional  
accessory). The kit includes a direc‐  
tional unit, aluminum hose, and hose  
clips.  
31  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Installation  
Appliance dimensions  
a
Mounting area for the exhaust ducting and power cable. In recirculation mode,  
only the power cord is required.  
b
Possible height range for appliance in vented mode  
c
Possible height range for appliance in recirculation mode  
d
Alternative installation with spacer frame  
e
Air vent positioned at the top for recirculation  
32  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Installation  
f
A power cord is required to connect the hood to the socket in the ceiling. With  
extraction mode flexible ducting is also required.  
Exhaust connection 6" (150 mm)  
Distance between cooktop and ventilation hood (S)  
Provided a larger distance is not given by the manufacturer of the cooktop, fol‐  
low the minimum safety distances between a cooktop and the bottom of the  
hood.  
Please also observe the information contained in the "IMPORTANT SAFETY IN‐  
STRUCTIONS" section.  
Minimum distance S  
Cooking appliance  
Miele appli‐  
ance  
Non-Miele ap‐  
pliance  
Electric/Induction cooktop  
24" (610 mm)  
Electric grill, deep fat fryer (electric)  
26" (660 mm)  
Multi-burner gas cooktop  
26" (660 mm) 30" (760 mm)  
43,000 BTU/hr (12.6 W),  
no burner > 15,000 BTU/hr (4.5 kW).  
Multi-burner gas cooktop  
73,800 BTU/hr (21.6 W),  
no burner > 16,500 BTU/hr (4.8 kW)  
30" (760 mm)  
Not possible  
Multi-burner gas cooktop  
> 73,800 BTU/hr (21.6 W),  
or one of the burners > 16,500 BTU/hr (4.8 kW)  
Single-burner gas cooktop  
20,500 BTU/hr (6 kW)  
26" (660 mm) 30" (760 mm)  
30" (760 mm)  
Single-burner gas cooktop  
27,600 BTU/hr (8.1 kW)  
Single-burner gas cooktop  
Not possible  
> 27,600 BTU/hr (8.1 kW)  
33  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Installation  
Installation recommendations  
Structural support  
– We also recommend a distance of at  
least 25 1/2" (650 mm) above electric  
cooktops to provide more workspace  
and easier cooking under the hood.  
– When selecting an installation height,  
always take the user height into con‐  
sideration. Users should have ample  
space to work comfortably on the  
cooktop and reach the ventilation  
hood controls with ease.  
– Please note that the greater the dis‐  
tance from the cooktop, the less ef‐  
fective the hood is at drawing in the  
cooking vapors.  
To achieve optimal vapor extraction,  
make sure that the hood covers the  
cooktop. The hood should be posi‐  
tioned centrally over the cooktop, not  
to the side or rear.  
The hood must be attached to rigid  
structural framing that is supported  
in its entirety by the ceiling joists, or  
to the ceiling joists directly. Do not  
attach the plate directly to the ceiling  
with anchors, toggle bolts, etc.  
– The cooktop should be no wider than  
the hood. Preferably, it should be  
narrower.  
– The mounting area must be easily  
accessible. The ventilation hood  
should be easy to reach and disas‐  
semble in case a service call is nec‐  
essary. This should be taken into  
consideration when planning the po‐  
sition of cupboards, shelves, ceilings  
or decorative elements in the vicinity  
of the ventilation hood.  
Removing the protective film  
The housing components are covered  
by a protective film to prevent them  
from becoming damaged during trans‐  
port.  
Please remove this film before instal‐  
ling the housing components. It can  
be peeled off easily without any addi‐  
tional tools.  
34  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Installation  
8
5
"
8
/
220 mm  
/
5
8
"
8
220 mm  
For vented mode:  
– Place a section of the exhaust duct‐  
ing in the ceiling and feed it down  
through the cross-sectional area as  
illustrated. Exhaust ducting of ap‐  
prox. 27 9/16" (700 mm) length is re‐  
quired between the ceiling and the  
hood exhaust socket.  
dai3435aus  
Draw two intersecting lines on the  
ceiling.  
– Secure the exhaust ducting to the ex‐  
haust socket, e.g. with a hose clip  
(available as an optional accessory)  
on flexible ducting.  
Place the power cord and guide it  
through the ceiling in the area shown.  
A power cord approx. 27 9/16"  
(700 mm) in length is required be‐  
tween the ceiling and the hood con‐  
nectors.  
35  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation  
Use a knife to release the four  
spacers and the two covers from the  
spacer frame supplied.  
Drill four holes 3/8" (10 mm), ap‐  
prox. 4 1/2" (115 mm) deep for the  
plugs supplied.  
Place the four plugs in the holes and  
screw in the four screws so that they  
protrude by approx. 1 3/16" (30 mm).  
Use the spacer frame as a drilling  
template. Place it on the ceiling with  
the arrows pointing forwards. Using  
the notches, align the spacer frame  
on the intersecting lines and make  
pencil marks for the drill holes.  
36  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation  
The spacer frame can be installed be‐  
tween the chimney and the ceiling. This  
creates a shadow which gives the illu‐  
sion of a gap between the ceiling and  
the chimney. This is useful if the ceiling  
is not level or is uneven. The hood is  
aligned vertically with the spacers sup‐  
plied. Visual irregularities between the  
chimney and the ceiling are then con‐  
cealed by the shadow.  
Mount the spacer frame onto the in‐  
stallation frame.  
If you wish to install the hood with the  
spacer frame, remove the four inserts  
from the fixing holes.  
37  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation  
Hang the installation frame on the  
four screws. The front of the frame is  
marked with a "V."  
Align the installation frame and se‐  
cure it with the screws.  
The spacers, which were removed  
from the spacer frame at the start,  
can be used to align the hood verti‐  
cally.  
If using the spacer frame, place the  
two covers into the fixing holes.  
38  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation  
Holding the installation frame secure‐  
ly, remove the two fixing screws and  
extend the installation frame to its  
maximum length.  
Replace the screws.  
The directional unit from recirculation  
kit DUI 32 (optional accessory) is instal‐  
led for recirculation mode (RM):  
Bend the four retaining tabs on the  
Fit the directional unit as shown, not‐  
installation frame outwards.  
ing the marking on the front.  
Place the power cord inside the in‐  
stallation frame.  
Bend the retaining tabs back and ap‐  
prox. 45° inwards to hold the direc‐  
tional unit in place.  
39  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation  
Secure the exhaust socket to the  
hose using a hose clip.  
Secure the hose to the directional  
unit socket using a hose clip.  
Check that the hose is held securely.  
Push the telescopic chimney over the  
installation frame:  
– with the recirculation grilles at the  
bottom for vented mode (AE),  
– with the recirculation grilles at the top  
for recirculation mode (RM).  
Bend the two retaining tabs outwards  
to prevent the telescopic chimney  
from slipping down again.  
40  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation  
Fit the four telescopic chimney  
clamps. When the screws are tight‐  
ened, the clamps spread out and  
push the telescopic expansion piece  
upwards.  
Bend back the two retaining tabs.  
Push the chimney over the telescopic  
chimney and bend the retaining tabs  
outwards again to prevent the chim‐  
ney from slipping down again.  
Tighten the screws only until the top  
edge of the telescopic chimney is  
evenly aligned with the ceiling or the  
spacer frame.  
41  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation  
A non-return flap is supplied with the  
hood or is already fitted in the exhaust  
socket of the motor unit (depending on  
model).  
With vented mode (AE) insert the  
non-return flap in the exhaust socket  
if your ducting system is not equip‐  
ped with one.  
Recirculation mode (RM) does not re‐  
quire the non-return flap to be insert‐  
ed. If there is one present, it should  
be removed.  
Hang the hood on the brackets, mak‐  
ing sure that the controls are at the  
front.  
Secure the hood with the screws  
supplied.  
42  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation  
Connect the power cord. See "Elec‐  
trical connection."  
Unscrew both screws from the instal‐  
lation frame again.  
Place the exhaust ducting onto the  
exhaust socket.  
The canopy can now be adjusted to the  
desired height, observing the permissi‐  
ble height ranges:  
– With vented mode: upwards as far as  
it will go, downwards only to the "A"  
marking.  
– With recirculation mode: upwards as  
far as the "U", downwards as far as it  
will go.  
Follow the instructions in "Appliance  
dimensions." Safety distances be‐  
tween the cooktop and ventilation  
hood must be observed.  
43  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation  
Raise the canopy to the desired  
height and secure it with the screws.  
Hold the chimney securely, bend  
back the retaining tabs and carefully  
lower it.  
The chimney will locate in the cut-out in  
the canopy.  
44  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation  
With recirculation mode (RM) ventila‐  
tion hoods, insert the OdorFree Char‐  
coal Filter.  
Remove the grease filters from the  
hood.  
Insert the safety screw on the inside.  
Carefully remove the protective foil  
from the grease filters.  
Reinsert the grease filters.  
45  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Exhaust duct  
WARNING: Danger of toxic fumes.  
Gas cooking appliances release car‐  
bon monoxide that can be harmful or  
fatal if inhaled.  
Remember that any constriction of  
the airflow will reduce extraction per‐  
formance and increase operating  
noise.  
To reduce the risk of fire and to prop‐  
erly exhaust air, the exhaust gases  
extracted by the hood should be  
vented outside of the building only.  
Do not vent exhaust air into spaces  
within walls or ceilings or in attics,  
crawl spaces or garages.  
If the exhaust duct is to be routed  
through an outside wall, we recom‐  
mend installing a telescopic wall vent  
or a rooftop vent (available as an op‐  
tional accessory).  
To reduce the risk of fire, only use  
metal ductwork.  
Please read and follow the "IMPOR‐  
TANT SAFETY INSTRUCTIONS" to  
reduce the risk of personal injury.  
Follow all local building codes when  
installing the hood.  
If the exhaust air is to be conducted  
into a vent flue, the intake piece must  
be aligned with the flow direction of  
the flue.  
Only use smooth pipes or flexible  
duct hoses made from non-flamma‐  
ble materials for exhaust ductwork.  
To achieve the greatest possible air  
extraction with the lowest noise lev‐  
els, please note the following:  
When installing the exhaust duct hor‐  
izontally, you must slope it away from  
the source by at least 1 cm per meter  
(3/8" per 3 1/4'). This ensures that  
condensate cannot drain back into  
the ventilation hood.  
– The diameter of the exhaust duct  
should not be less than 6" (150 mm).  
– If flat exhaust ducts are used, the  
cross section should not be smaller  
than that of the exhaust connector.  
If the exhaust duct is to be routed  
through rooms, ceiling space etc., the  
temperatures in these different areas  
may differ greatly, which means that  
the problem of condensation will  
need to be addressed. The exhaust  
duct will need to be insulated.  
– The exhaust duct should be as short  
and straight as possible.  
– If elbows are needed, make sure they  
have a large radius.  
– The exhaust duct itself must not be  
kinked or compressed.  
– Make sure that all connections are  
secure and airtight.  
46  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Exhaust duct  
Condensate trap  
In addition to insulating the exhaust  
duct, we recommend installing a con‐  
densate trap to collect and evaporate  
any condensate which might accumu‐  
late.  
Condensate traps are available for ex‐  
haust ducts with a diameter of 5"  
(125 mm) or 6" (150 mm).  
When installing a condensate trap,  
make sure that it is positioned verti‐  
cally and, if possible, directly above  
the hood outlet duct collar.  
The arrow on the housing indicates  
the direction of airflow.  
47  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Electrical connection  
Grounding Instructions  
WARNING: TO REDUCE THE RISK  
OF FIRE, ELECTRIC SHOCK, OR IN‐  
JURY TO PERSONS, OBSERVE THE  
FOLLOWING:  
All electrical work should be per‐  
formed by a qualified electrician in  
strict accordance with national regu‐  
lations (for USA: ANSI-NFPA 70) and  
local safety regulations. Installation,  
repairs and other work by unqualified  
persons could be dangerous.  
WARNING - Improper grounding can  
result in a risk of electric shock.  
This appliance must be grounded. In  
the event of an electrical short cir‐  
cuit, grounding reduces the risk of  
electric shock by providing a path of  
least resistance.plug.  
If there is any doubt, have the elec‐  
trical system of the house checked  
by a qualified electrician.  
Ensure that power to the appliance is  
OFF while installation or repair work  
is performed.  
To increase security before the ma‐  
chine is installed, it is recommended  
to install a protective switch(30mA).  
Verify that the voltage, load and cir‐  
cuit rating information found on the  
data plate (located behind the baffle  
filters), match the household electri‐  
cal supply before installing the hood.  
Use only with ventilation hood cord-  
connection kits that have been in‐  
vestigated and found acceptable for  
use with this model hood.  
The hood must be hard wired ac‐  
cordingly:  
Black/Red wire: connect to L1 (live)  
White wire: connect to N (neutral)  
Green wire: connect to GND (ground)  
If there is any question concerning  
the electrical connection of this ap‐  
pliance to your power supply, please  
consult a licensed electrician or call  
Miele’s Technical Service Depart‐  
ment.  
WARNING: THIS APPLIANCE MUST  
BE GROUNDED  
48  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Activating Con@ctivity 2.0  
Activating the ventilation hood  
Installation of the Con@ctivity  
2.0 stick  
In order for you to be able to use the  
Con@ctivity 2.0 function, the cooktop  
must be equipped with a Con@ctivity  
2.0 stick.  
The cooktop and hood must be  
turned off.  
Press the delayed shut down button  
for approx. 10 seconds until 1  
lights up in the fan setting display.  
See the relevant installation instruc‐  
tions of the Con@ctivity 2.0 stick.  
Next, tap the following buttons in  
succession:  
– The 1 button,  
Activating the Con@ctivity 2.0  
function  
– Then the IS button,  
To use the Con@ctivity 2.0 function, the – And then the lighting button .  
radio link between the cooktop and the  
The hood is in log on / log off mode.  
ventilation hood must be activated.  
If the wireless connection is already ac‐  
tivated, 2 and 3 will light up at the same  
time.  
Both appliances must be installed and  
operational.  
Wireless connection must be activated  
If there is no wireless connection, 2 and  
on the ventilation hood and the cooktop 3 will flash constantly (Con@ctivity 2.0  
at the same time. Activation on the ven‐ is already activated or a remote control  
tilation hood is described below.  
Activation on the cooktop is described  
in the relevant operating and installation  
instructions. Please refer to the operat‐  
ing instructions before starting.  
Activate the ventilation hood first, then  
the cooktop.  
is logged on).  
To activate Con@ctivity 2.0, tap the  
IS button.  
The search for a wireless connection  
will start.  
As this is happening, begin activation  
on the cooktop.  
49  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Activating Con@ctivity 2.0  
Activating the cooktop  
Activation failed  
While the ventilation hood is search‐  
ing for a wireless connection, start  
activation on the cooktop.  
More information can be found in the  
operating instructions for the cook‐  
top.  
If a wireless connection cannot be  
established despite activation of the  
Con@ctivity function on the ventila‐  
tion hood and cooktop, the function  
must first be deactivated and then re‐  
activated on both appliances.  
When the cooktop registers that con‐  
nection has been established, con‐  
firm activation on the ventilation hood  
with the delayed shut-down button  
515. All indicators will go out.  
Deactivating Con@ctivity 2.0  
Deactivation on the ventilation hood  
is similar to the activation procedure.  
Select the IS instead of the 1 button.  
To deactivate the cooktop, please re‐  
fer to the corresponding operating in‐  
structions.  
Confirm activation on the cooktop.  
The Con@ctivity 2.0 function is now  
ready for use.  
Please keep in mind that disabling the  
connection will also disable any re‐  
mote control function being used. The  
remote control must then be reactivat‐  
ed.  
If you do not confirm within 4 minutes,  
activation will be canceled.  
You only need to carry out the activa‐  
tion procedure once. If the appliances  
are disconnected from the electricity  
supply, for example during a loss of  
power, they will still remain activated.  
50  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Service and warranty  
For faults that you cannot resolve on  
your own, please contact your Miele  
dealer or Miele Technical Service.  
The telephone number for the Technical  
Service Department is listed at the back  
of these instructions.  
When contacting Miele, please state  
the model and serial number of your  
ventilation hood.  
These can be found on the data plate.  
Location of the data plate  
The data plate is visible once you have  
removed the grease filters.  
Warranty  
For further information, please refer to  
your warranty booklet.  
51  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Technical data  
Fan motor  
350 W  
4 x 3 W  
Overhead lighting  
Total connected load  
Voltage, Frequency  
Fuse rating  
362 W  
120 V AC, 60 Hz  
15 A  
Power cord length  
Weight  
6.5 ft. (2 m)  
Optional accessories for recirculation mode:  
Recirculation kit DUW 32 and OdorFree Charcoal Filter DKF 12  
Contains  
FCC ID: 2ACUWEI8800  
IC: 5669C-EI8800  
This device complies with Part 15 of the FCC Rules and with Industry Canada li‐  
cence-exempt RSS standard(s). Operation is subject to the following two condi‐  
tions: (1) this device may not cause harmful interference, and (2) this device must  
accept any interference received, including interference that may cause undesired  
operation.  
52  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Please have the model and serial number  
of your appliance available before  
contacting Technical Service.  
U.S.A.  
Canada  
Miele, Inc.  
Importer  
Miele Limited  
National Headquarters  
9 Independence Way  
Princeton, NJ 08540  
Headquarters and Miele Centre  
161 Four Valley Drive  
Vaughan, ON L4K 4V8  
800-843-7231  
609-419-9898  
609-419-4298  
Phone:  
Fax:  
Customer Care Centre  
Phone:  
800-565-6435  
905-532-2272  
Technical Service & Support  
Nationwide  
800-999-1360  
888-586-8056  
Phone:  
Fax:  
Germany  
Manufacturer  
Miele & Cie. KG  
Carl-Miele-Straße 29  
33332 Gütersloh  
53  
Download from Www.Somanuals.com. All Manuals Search And Download.  
DA 6690 D  
en-US  
M.-Nr. 09 805 980 / 00  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Miele Vacuum Cleaner S4212 User Manual
MSi Computer Hardware G52 M6570XA G22 User Manual
National Instruments Car Stereo System 320571 01 User Manual
NEC Projector MultiSync MT840 User Manual
Niles Audio Portable Speaker HPS 4 HPS 6 User Manual
NordicTrack Home Gym NTEL42552 User Manual
NuTone Ventilation Hood QTREN User Manual
Oster Toaster 125508 User Manual
Panasonic IP Phone KX T7050 User Manual
Panasonic Laptop CF Y4 User Manual