Miele Ventilation Hood DA270 User Manual

Operating and Installation  
Instructions  
Ventilation System  
DA 270  
To prevent accidents  
and machine damage,  
read these instructions  
before  
UV  
installation or use.  
M.-Nr. 05 854 670  
Download from Www.Somanuals.com. All Manuals Search And Download.  
IMPORTANT SAFETY INSTRUCTIONS  
Read these Operating Instructions carefully before installing or  
using the Ventilation System.  
This appliance is designed to vent  
This appliance is intended for  
residential use only. Use the  
appliance only for its intended  
purpose. The manufacturer cannot  
be held responsible for damages  
caused by improper use of the  
hood.  
cooking smoke and odors only.  
Be certain your appliance is  
properly installed and grounded by  
a qualified technician.  
To guarantee the electrical safety of this  
appliance, continuity must exist  
between the appliance and an effective  
grounding system. It is imperative that  
this basic safety requirement be met. If  
there is any doubt, have the electrical  
system of the house checked by a  
qualified electrician. The manufacturer  
can not be held responsible for  
damages caused by the lack, or  
inadequacy of, an effective grounding  
system.  
This appliance complies with current  
safety requirements. Improper use of  
the appliance can lead to personal  
injury and material damage.  
READ AND SAVE THESE  
INSTRUCTIONS  
Before connecting the appliance to  
the power supply make sure that  
the voltage and frequency listed on the  
data plate correspond with the house-  
hold electrical supply. This data must  
correspond to prevent machine  
damage. Consult a qualified electrician  
if in doubt.  
CAUTION  
For General Ventilating Use Only.  
Do Not Use To Exhaust Hazardous  
Or Explosive Materials And Vapors.  
Installation work and repairs should  
only be performed by a qualified  
technician in accordance with all  
applicable codes and standards.  
Repairs and other work by unqualified  
persons could be dangerous and the  
manufacturer will not be held  
responsible.  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
IMPORTANT SAFETY INSTRUCTIONS  
This equipment is not designed for Use  
maritime use or for use in mobile  
Do not allow children to play with  
installations such as caravans or air-  
craft. However, under certain conditions  
it may be possible for an installation in  
these applications. Please contact the  
nearest Miele dealer or the Technical  
Service Department with specific  
requirements.  
or operate the appliance or its  
controls. Supervise its use by the  
elderly or infirm.  
Be careful when preparing a  
flambé beneath the hood.  
Flames may be drawn up into the hood  
by the suction or grease filters may  
catch fire.  
Before servicing or cleaning the  
unit, switch power off at the service  
panel and lock the service disconnect-  
ing means to prevent power from being  
switched on accidentally. When the  
service disconnecting means can not  
be locked, securely fasten a prominent  
warning device, such as a tag, to the  
service panel.  
Never operate gas burners without  
pots.  
Do not leave cooking surfaces  
unattended while in use. Over-  
heated food, oil and grease can catch  
fire.  
Do not use the hood without the  
grease filters in place.  
Before discarding an old  
appliance, unplug it from the  
Clean the grease filters regularly.  
Dirty filters are a fire hazard.  
power supply and remove the power  
cord and any doors to prevent hazards.  
Do not use a steam cleaner to  
clean the hood. Steam could  
penetrate electrical components and  
cause a short circuit.  
In areas subject to infestation by  
cockroaches or other pest, keep  
the appliance and its surroundings  
clean at all times. Any damage caused  
by cockroaches or other pest will not  
be covered under warranty.  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
IMPORTANT SAFETY INSTRUCTIONS  
, WARNING - TO REDUCE  
THE RISK OF A RANGE TOP  
GREASE FIRE:  
, WARNING  
TO REDUCE THE RISK OF INJURY  
TO PERSONS IN THE EVENT OF A  
RANGE TOP GREASE FIRE,  
OBSERVE THE FOLLOWING:  
Never leave surface units  
unattended at high settings.  
Boilovers cause smoking and greasy  
spillovers may ignite. Heat oils slowly  
on low or medium settings.  
SMOTHER FLAMES with a close  
fitting lid, cookie sheet, or metal  
tray, then turn off the burner.  
BE CAREFUL TO PREVENT BURNS.  
If the flames do not go out immediately,  
EVACUATE AND CALL THE FIRE  
DEPARTMENT.  
Always turn the hood "ON" when  
cooking at high heat or when  
cooking flaming foods.  
Clean ventilating fans frequently.  
Grease should not be allowed to  
accumulate on the fan or filter.  
NEVER PICK UP A FLAMING  
PAN - You may be burned.  
DO NOT USE WATER, including  
wet dishcloths or towels - a violent  
steam explosion will result.  
Use proper pan size. Always use  
cookware appropriate for the size  
of the surface element.  
Use an extinguisher  
ONLY IF:  
You know you have a Class ABC  
extinguisher, and you already know  
how to operate it.  
– The fire is small and contained in the  
area where it started.  
– The fire department is being called.  
You can fight the fire with your back  
to an exit.  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
IMPORTANT SAFETY INSTRUCTIONS  
Installation  
Never connect an exhaust hood to  
an active chimney, dryer vent, vent  
flue, or room ventilating ductwork. Seek  
professional advice before connecting  
an exhaust hood vent to an existing,  
, WARNING  
To reduce the risk of fire, only  
use metal ductwork.  
When installing the hood, follow the inactive chimney or vent flue.  
recommended minimum safety  
Ducted fans must always be  
distances between a Miele cooktop and  
vented outdoors.  
the hood:  
Make sure that the airflow in the  
room is sufficient for combustion  
– 22" (55 cm) above electric cooktops,  
– 26" (65 cm) above gas cooktops,  
– 26" (65 cm) above an open grill.  
and exhausting of all non-electric  
heating appliances (water heaters, gas  
cooktops, gas ovens, etc.), otherwise  
backdrafts may occur. Follow the  
heating manufacturer’s guidelines and  
safety standards or those published by  
the National Fire Protection Association  
(NFPA), or the American Society for  
Heating, Refrigeration and Air  
If local building codes require a greater  
safety distance, follow their require-  
ment.  
For non-Miele cooking appliances  
maintain the safety distances recom-  
mended by the appliance manufacturer  
in their instructions.  
If there is more than one appliance  
beneath the hood and they have differ-  
ent minimum safety distances always  
select the greater distance.  
Conditioning Engineers (ASHRAE).  
If in doubt, consult an experienced  
professional.  
Be careful not to damage hidden  
electrical wiring or plumbing when  
cutting or drilling into the wall or ceiling.  
Do not use an extension cord to  
connect the appliance to electricity.  
Extension cords do not guarantee the  
required safety of the appliance, (e.g.  
danger of overheating).  
Do not install this hood over  
cooktops burning solid fuel.  
Any fittings, sealant, or materials  
used to install the ductwork must  
be made of approved non-flammable  
materials.  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
Functional description  
The hood offers two modes of  
operation:  
Air extraction  
The air is drawn in and cleaned by the  
grease filters and directed outside.  
The hood comes equipped with a  
non-return flap. This flap automatically  
closes when the hood is turned off so  
that no exchange of outside air and  
room air can occur. When the hood is  
turned on, the air pressure of the  
exhaust fan automatically opens the  
flap blowing the inside air and cooking  
odors outside.  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Guide to the hood  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Guide to the hood  
a Cover plate  
b Chimney  
c Canopy  
d Indirect lighting  
e Overhead lighting  
f Grease filter  
g Indirect lighting On/Off  
switch  
h Overhead lighting button  
The button turns the light on and off  
and also dims the light.  
The lighting can be used independently  
from the fan.  
i On/Off button  
j Fan power selection  
k Delayed shut down  
This button activates the Delayed Shut  
Down feature. The fan can be set to  
turn off automatically after either 5 or  
15 minutes.  
l Grease filter button  
The indicator next to the grease filter  
button lights when the grease filters  
need to be cleaned.  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
Operation  
Turning on the fan  
Fan performance  
The maximum air flow capacity is  
625 cfm. Factors such as narrow duct  
diameter and bends will affect this  
value.  
^ Press the On/Off button.  
There will also be a slight decrease in  
airflow for hoods operated in  
recirculation mode due to the active  
charcoal filter.  
The fan runs at power level “lI”.  
The indicator lights.  
Selecting the power level  
Level 1 operates at 40% capacity  
Level 2 operates at 60% capacity  
Level 3 operates at 80% capacity  
Level 4 operates at 100% capacity  
^ Use the _ controls to select the  
desired power level.  
& =increases the fan speed  
$ =decreases the fan speed  
Level "1" to "3" (green indicators) are  
usually sufficient for normal cooking.  
Intensive setting  
Level "4" (yellow indicator) should be  
used for a short period when frying or  
cooking food with a strong aroma.  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Operation  
Turning off the fan  
Delayed Shut Down  
If odors or smoke remain in the kitchen  
after cooking has been completed, the  
Delayed Shut Down feature can be  
selected to allow the hood to continue  
running for either 5 or 15 minutes.  
^ Press the On/Off button to turn the  
fan off.  
The indicator goes out.  
Automatic Safety Shut Off  
^ Press the Delayed Shut Down button  
while the fan is still running.  
The fan will turn off automatically 10  
hours after the last button was activated.  
The lighting however will remain on.  
Press once = 5 minutes delay  
(left indicator lights)  
Press twice = 15 minutes delay  
(right indicator lights)  
^ Press the On/Off button to turn the  
fan back on again.  
To cancel the Delayed Shut Down  
feature press the button again.  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Operation  
Turning the lighting on/off  
Indirect lighting  
The overhead lighting can be turned  
on and off independently of the fan.  
^ Press the indirect lighting switch to "I"  
to turn on the indirect lighting.  
^ Press the light button briefly to turn  
on the lighting.  
^ Press the indirect lighting switch to  
"O" to turn off the indirect lighting.  
The light button indicator illuminates.  
^ Press the light button briefly again to  
turn off the lighting.  
The light button indicator will go out.  
Dimming the lighting  
The brightness of the lighting can be  
adjusted.  
^ While the lighting is turned on, press  
the light button.  
The lighting will dim until the button is  
released.  
^ If the button is pressed again, the  
lighting will brighten until the button is  
released.  
If the button is pressed continuously,  
the light will cycle between bright and  
dark.  
^ Press the light button again to turn off  
the lighting.  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Operation  
Filter timers  
Checking the filter timers  
To check the percentage of time  
already used:  
Grease filters  
A timer monitors the hours of operation.  
The indicator for the grease filter will  
light after 30 hours of fan operation. The  
grease filters must then be cleaned.  
^ Press the On/Off button to turn the  
fan on.  
After the grease filters have been  
cleaned and put in place, the grease  
filter timer must be reset.  
^ Press the grease button.  
^ To do this, press the grease filter  
button for about 3 seconds.  
The number of flashing _ indicators  
The indicator will go out.  
show the percentage of programmed  
hours that have been used.  
1 indicator = less than 25 %  
2 indicators = less than 50 %  
3 indicators = less than 75 %  
4 indicators = less than 100 %  
This information will remain stored in  
memory in the event of a power failure.  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Operation  
Reprogramming the grease  
filter timer  
The indicator for the grease filter and  
one of the _ indicators will flash.  
The grease filter timer is preset to 30  
hours. This time can be lengthened or  
shortened to 20, 30, 40 or 50 hours.  
– A time of 20 hours should be  
programmed in kitchens with  
frequent pan or deep frying.  
The lit indicator shows the programmed  
time:  
– A time of 20 hours should also be  
programmed if the kitchen is only  
used occasionally to prevent grease  
which has accumulated over a long  
period of time from hardening on the  
filters making cleaning more difficult.  
1st indicator from the left = 20 hours  
2nd indicator from the left = 30 hours  
3rd indicator from the left = 40 hours  
4th indicator from the left = 50 hours  
^ Use the $ or & button to select the  
desired time.  
^ Store the selection by pressing the  
grease filter button.  
^ Press the On/Off button to turn off the  
fan.  
If the procedure is not stored within  
4 minutes of programming, the hood  
will automatically default to the "old"  
data.  
Press the Delayed Shut Down and  
grease filter buttons at the same time.  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Cleaning and Care  
Stainless steel  
Before cleaning or servicing the  
hood, disconnect it from the power  
supply by either removing the fuse,  
unplugging it from the outlet or  
manually "tripping" the circuit  
breaker.  
Stainless steel surfaces can be cleaned  
using a non-abrasive stainless steel  
cleaner.  
To help prevent resoiling, a conditioner  
for stainless steel can be applied.  
Cleaning the casing  
Stainless steel colored controls  
Warning: Never use abrasive clean-  
ers, scouring pads, steel wool or  
caustic (oven) cleaners on the hood.  
They will damage the surface.  
These controls may become dis-  
colored or damaged if not cleaned  
regularly.  
Do not use a stainless steel cleaner  
on these controls.  
^ All external surfaces and controls can  
be cleaned with warm water and liq-  
uid dish soap applied with a soft  
sponge.  
^ Wipe dry using a soft cloth.  
Do not use too much water when  
cleaning the controls. Water could  
penetrate the electronics and cause  
damage.  
^ Glass surfaces can be cleaned using  
glass cleaner.  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Cleaning and Care  
Grease filters  
Cleaning the grease filters  
The reusable metal grease filters  
remove solid particles from the vented  
kitchen air (grease, dust, etc).  
^ Clean the filters  
- by hand: use a scrub brush in  
warm water with a mild detergent.  
- in a dishwasher: place the filters  
vertically in the lower basket, making  
sure that the spray arm is not  
blocked.  
The grease filters should be cleaned  
every 3 - 4 weeks or whenever the  
grease filter indicator lights.  
Depending on the detergent, clean-  
ing the grease filters in a dishwasher  
may cause permanent discoloration  
of the filter surface. Performance of  
the filter will not be affected by this  
discoloration.  
A dirty filter is a fire hazard.  
^ After cleaning, the filters can be  
placed on a towel to air dry.  
^ While the filters are removed, clean  
any dirt or grease from the filter  
casing to prevent the risk of fire.  
^ To remove the grease filters press the  
locking clips in towards the middle of  
the filter. Support grease filter so that  
it does not fall on to the cooktop.  
16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Cleaning and Care  
Inserting the grease filters  
When putting the grease filters back  
make sure that the locking clips are  
visible facing the cooking surface.  
If the filters are incorrectly installed,  
insert a small screwdriver into the slit  
along its edge to disengage it from the  
casing.  
^ After returning the grease filters,  
press the grease filter button for 3  
seconds to reset the timer. The  
indicator light will go out.  
^ If the grease filters are cleaned  
before the grease filter timer has  
reached its maximum, press the  
grease filter button for 6 seconds to  
reset the counter to zero.  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Cleaning and Care  
Changing the light bulb  
Before changing the light bulbs,  
disconnect the hood from the power  
supply by either removing the fuse,  
unplugging it, or manually "tripping"  
the circuit breaker.  
When in use halogen bulbs become  
extremely hot, and they can burn  
your hands. Do not attempt to  
change the bulbs until they have  
had sufficient time to cool down.  
^ To change the halogen bulb first  
remove the lamp cover, a.  
^ Pull the bulb, b, out of its socket and  
replace with a new one.  
Do not touch the bulb surface.  
Fingerprints or body oils deposited  
on the bulb will decrease the life of  
the bulb.  
Follow the bulb manufacturer’s  
instructions.  
^ Return the lamp cover, a.  
Never use the lighting without the  
lamp cover, a, in place. The glass is  
specially made to filter harmful light  
rays.  
18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
After Sales Service  
In the event of a fault which you cannot  
correct yourself please contact:  
Your Miele Dealer  
or  
– The Miele Technical Service  
Department  
USA 1-800-999-1360  
techserv@mieleusa.com  
CDN 1-800-565-6435  
service@miele.ca  
When contacting the Technical Service  
Department, please quote the model  
and serial number of your appliance.  
These are shown on the data plate  
which is visible when the grease filter is  
removed.  
19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation Instructions  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Caring for the environment  
Disposal of packing material  
Disposal of an old appliance  
The cardboard box and packing  
materials protect the appliance during  
shipping. They have been designed to  
be biodegradable and recyclable.  
Please recycle.  
Old appliances may contain materials  
that can be recycled. Please contact  
your local recycling authority about the  
possibility of recycling these materials.  
Before discarding an old hood,  
unplug it from the outlet and cut off  
its power cord to prevent hazards.  
Ensure that any plastic wrappings,  
bags etc. are disposed of safely and  
kept out of the reach of children.  
Danger of suffocation!  
23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Structural support  
The ceiling mounting plate will  
support the weight of the hood. This  
ceiling plate must be attached to  
rigid structural framing that is  
supported in its entirety by the  
ceiling joists, or to the ceiling joists  
directly. Do not attach the plate  
directly to the ceiling by using  
anchors, mollies or toggle bolts.  
24  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Electrical data  
Important  
All electrical work should be  
The hood must be hard wired  
accordingly:  
performed by a qualified electrician  
in strict accordance with national  
and local safety regulations.  
Installation, repairs and other work  
by unqualified persons could be  
dangerous. The manufacturer is not  
responsible for unauthorized work.  
Ensure that power to the appliance  
is OFF while installation or repair  
work is performed.  
Black/Red wire:. . . . connect to L1 (live)  
White wire: . . . . . connect to N (neutral)  
Green wire: . . connect to GND (ground)  
Maximum load . . . . . . . . . . . . . . . 450 W  
Overhead lighting . . . . . . . . . . 4 x 20 W  
Indirect lighting . . . . . . . . . . . . 2 x 10 W  
Verify that the voltage, load and circuit  
rating information found on the data  
plate (located behind the grease  
filters), match the household electrical  
supply before installing the hood.  
Voltage . . . . . . . . . . . . . . . . . . . . . 120 V  
Frequency . . . . . . . . . . . . . . . . . . 60 Hz  
Circuit rating. . . . . . . . . . . . . . . . . . 15 A  
If there is any question concerning the  
electrical connection of this appliance  
to your power supply, please consult a  
licensed electrician or Miele’s Technical  
Service.  
USA 1-800-999-1360  
CDN 1-800-565-6435  
WARNING:  
THIS APPLIANCE MUST BE  
GROUNDED  
25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Appliance dimensions  
a Mounting bolt holes  
b Cut out for power cord  
c Exhaust connection 6" (150 mm) diameter  
26  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Installation  
Do not install this exhaust hood over  
cooktops burning solid fuel.  
When installing the hood, adhere to  
the following minimum distance (S)  
between the top of a Miele cooking  
surface and the bottom of the hood:  
- 22" (55 cm) above electric cooktops  
- 26" (65 cm) above gas cooktops  
- 26" (65 cm) above an open grill  
For non-Miele appliances, maintain  
the safety distances recommended  
by the cooktop manufacturer in their  
installation instructions.  
If there is more than one appliance  
beneath the hood and they have  
different minimum safety distances  
always select the greater distance.  
^ Mark a line on the ceiling going from  
the rear of the cooktop towards the  
front and centered over the cooktop.  
^ Cut a 7 1/2" (190 mm) hole in the  
ceiling for the exhaust duct to pass  
through. The exhaust connection has  
a 6" (150 mm) diameter.  
Observe local building codes.  
See "Important Safety Instructions"  
for further information.  
26" (65 cm) is recommended for all  
installations to allow for optimum work  
space under the hood.  
CAUTION:  
During the installation process,  
please be careful of sharp edges  
that can cause harm.  
27  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Installation  
^ Feed the ductwork and power cord  
through their respective holes in the  
ceiling.  
If 6" (150 mm) ductwork is not possible  
then 5" (125 mm) ductwork can be  
used in conjunction with a reducing  
collar available from Technical Service  
(see "Installation / Air extraction" for  
further details).  
^ Hold the mounting plate up to the  
ceiling so that the orange arrow faces  
the front of the hood and aligns with  
the line drawn on the ceilling.  
Mark the position of the four mount-  
ing bolts a for securing the mounting  
plate and determining the position of  
the hole the power cord b will pass  
through.  
Select the hole providing the shortest  
route for the power cable b to reach  
the power terminal located at the top  
of the hood’s chimney.  
^ Drill four 3/16" (5 mm) holes in the  
ceiling.  
The S10 wall anchors included in the  
packaging are not for use in  
USA/CDN.  
Be certain that the ceiling is stable  
enough to support the hood.  
28  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation  
^ Secure the ducting to the mounting  
plate using a hose clip.  
^ Insert the short edge of the two  
spring clips into their slots from  
below and pivot them 90° so that the  
tab faces the center of the mounting  
brake.  
^ Pull the power cord through the  
mounting plate.  
^ Insert the four countersunk screws  
M 6 x 20 into the recessed holes from  
above.  
^ Tape the screws from above to  
prevent them from being pushed  
upwards when the nuts are tightened.  
29  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation  
^ Screw the mounting plate through the  
ceiling and into the structural framing  
using 8 x 60 lag bolts and washers.  
Once tight, make sure that the  
mounting plate can safely support  
the weight of the hood.  
^ Using at least two people, lift the  
hood and guide the spring clips  
through their respective slots in the  
flange at the top of the chimney.  
Make sure they click into place and that  
the hood is hanging securely from the  
spring clips before allowing them to  
carry the weight.  
30  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation  
^ Bolt the flange firmly to the ceiling  
using the four M6 nuts.  
^ Finally, being careful not to scratch  
the chimney, push the cover plate up  
until the spring fixing clips click into  
place. If installed correctly, the cover  
should be secure and flush against  
the ceiling.  
^ Shorten the power cord as much as  
possible and attach it to the terminal  
block inside the chimney. See  
"Electrical data".  
Before making the electrical connec-  
tion read the "Important Safety  
Instructions" and "Electrical data"  
sections.  
^ Before using the appliance remove  
the grease filter and remove the  
protective foil from the filter frame.  
Reseat the filter.  
31  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Air extraction  
WARNING  
To reduce the risk of fire, only use  
metal ductwork.  
Danger of toxic fumes.  
Gas cooking appliances release  
carbon monoxide that can be harm-  
ful or fatal if inhaled. The exhaust  
gases extracted by the hood  
should be vented outside of the  
building only.  
Do not terminate the exhaust  
ducts in attics, garages,  
crawlspaces, etc.  
CAUTION  
To reduce risk of fire and to properly  
exhaust air, be sure to duct air  
outside. Do not vent exhaust air into  
spaces within walls or ceilings or  
into attics, crawl spaces, or garages.  
– Use smooth or flexible pipes made  
from approved non-flammable  
materials for exhaust ducting.  
Please read and follow the "Important  
Safety Instructions" to reduce the risk  
of personal injury. Follow all local build-  
ing codes when installing the hood.  
– Where the ductwork is horizontal, it  
must slope away from the hood at  
least 1/8" per foot (1cm per meter) to  
prevent condensation dripping into  
the appliance.  
Exhaust ducting and connections  
– The ducting should be as short and  
straight as possible, and the number  
of sharp bends should be minimized.  
– If the exhaust is ducted through an  
outside wall, a Miele Telescopic Wall  
Vent can be used.  
– For most efficient air extraction, the  
diameter of the ductwork should not  
be less than 6" (150 mm). Use of flat  
ducts also reduces the air extraction  
efficiency.  
– Noise levels of the hood will increase  
if flat ducts or round ducts of less  
than 6" (150 mm) in diameter are  
used.  
32  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Air extraction  
– If the exhaust is ducted into an  
inactive flue, the air must be expelled  
parallel to the flow direction of the  
flue.  
Never connect an exhaust hood to  
an active chimney, dryer vent, vent  
flue, or room venting ductwork. Seek  
professional advice before connect-  
ing an exhaust hood vent to an  
existing, inactive chimney or vent  
flue.  
– If the ductwork runs through rooms,  
ceilings, garages, etc. where temper-  
ature variations exist, it may need to  
be insulated to reduce condensation.  
In some cases, a condensate trap  
may also be required to collect and  
evaporate any condensate which  
may occur.  
When installing a condensate trap,  
ensure that it is positioned vertically  
and if possible directly above the  
exhaust outlet.  
33  
Download from Www.Somanuals.com. All Manuals Search And Download.  
34  
Download from Www.Somanuals.com. All Manuals Search And Download.  
35  
Download from Www.Somanuals.com. All Manuals Search And Download.  
M.-Nr. 05 854 670 / V00  
Alteration rights reserved / 0203  
This paper is bleached without the use of chlorine.  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Miele Freezer KFN 8452 SD User Manual
Murphy Switch WD100 User Manual
NAD Stereo Amplifier CI9060 User Manual
NeumannBerlin Microphone KK 131 User Manual
Nikon Binoculars 10x25DCF User Manual
Olympus Camera Lens V311060BU000 User Manual
Olympus Security Camera D 220; User Manual
Oregon Scientific Heart Rate Monitor SE188 User Manual
Panasonic Camcorder AG HPX370 User Manual
Panasonic Electric Shaver ES7017 User Manual