Operating and Installation
Instructions
Ventilation System
DA 251-4
DA 252-4
DA 259-4
en - US, CA
To prevent accidents
and machine damage,
read these instructions
before
installation or use.
M.-Nr. 06 712 760
Download from Www.Somanuals.com. All Manuals Search And Download.
IMPORTANT SAFETY INSTRUCTIONS
Read these Operating Instructions carefully before installing or
using the Ventilation System.
This appliance is designed to vent
~
This appliance is intended for
residential use only. Use the
appliance only for its intended
purpose. The manufacturer cannot
be held responsible for damages
caused by improper use of the
hood.
cooking smoke and odors only.
Be certain your appliance is
~
properly installed and grounded by a
qualified technician.
To guarantee the electrical safety of this
appliance, continuity must exist
between the appliance and an effective
grounding system. It is imperative that
this basic safety requirement be met. If
there is any doubt, have the electrical
system of the house checked by a
qualified electrician. The manufacturer
cannot be held responsible for
damages caused by the lack, or
inadequacy, of an effective grounding
system.
This appliance complies with current
safety requirements. Improper use
of the appliance can lead to
personal injury and material
damage.
READ AND SAVE THESE
INSTRUCTIONS
Before connecting the appliance to
~
the power supply make sure that the
voltage and frequency listed on the
data plate correspond with the
household electrical supply. This data
must correspond to prevent machine
damage. If in doubt consult a qualified
electrician.
,CAUTION
For General Ventilation Use Only.
Do not use to exhaust hazardous or
explosive materials and vapors.
Installation work and repairs should
~
only be performed by a qualified
technician in accordance with all
applicable codes and standards.
Repairs and other work by unqualified
persons could be dangerous and the
manufacturer will not be held
responsible.
3
Download from Www.Somanuals.com. All Manuals Search And Download.
IMPORTANT SAFETY INSTRUCTIONS
This equipment is not designed for
Use
~
maritime use or for use in mobile
installations such as recreational
vehicles or aircraft. However, under
certain conditions it may be possible for
installation in these applications. Please
contact the nearest Miele dealer or the
Technical Service Department with
specific requirements.
Do not allow children to play with or
~
operate the appliance or its controls.
Supervise its use by the elderly or
infirm.
Do not flambé or grill with an open
~
flame beneath the hood.
Flames could be drawn up into the
hood by the suction and the grease
filters may catch fire.
Before servicing or cleaning the unit,
~
switch power off at the service panel
and lock the service disconnecting
means to prevent power from being
switched on accidentally. If the service
disconnecting means cannot be
locked, securely fasten a prominent
warning, such as a tag, to the service
panel.
Never operate gas burners without
~
cookware. Turn the burner off when not
in use. Adjust the burner so that the
flames do not extend beneath the
cookware. Do not overheat the
cookware, e.g. when using a wok. The
hood can be damaged due to
excessive heat from the burners and
the cookware.
Before discarding an old appliance,
~
unplug it from the power supply and
remove the power cord and any doors
to prevent hazards.
Do not use the hood without the
~
grease filters in place.
Clean the grease filters regularly.
~
Dirty filters are a fire hazard.
Do not use a steam cleaner to clean
~
the hood. Steam could penetrate the
electrical components and cause a
short circuit.
Always turn on the hood when using
~
the cooktop to prevent damage from
condensation.
4
Download from Www.Somanuals.com. All Manuals Search And Download.
IMPORTANT SAFETY INSTRUCTIONS
, WARNING - TO REDUCE
THE RISK OF A COOKTOP
, WARNING
TO REDUCE THE RISK OF INJURY
TO PERSONS IN THE EVENT OF A
COOKTOP GREASE FIRE, OBSERVE
THE FOLLOWING:
GREASE FIRE:
Never leave surface units
~
unattended at high settings. Boilovers
cause smoking and greasy spillovers
may ignite. Heat oils slowly on low or
medium settings.
SMOTHER FLAMES with a close
~
fitting lid, cookie sheet, or metal tray
then turn off the burner.
BE CAREFUL TO PREVENT BURNS.
If the flames do not go out immediately,
EVACUATE AND CALL THE FIRE
DEPARTMENT.
Always turn the hood on when
~
cooking at a high heat.
Clean ventilation fans frequently.
~
Grease should not be allowed to
accumulate on the fan or filter.
NEVER PICK UP A FLAMING PAN
~
- You may be burned.
Use the proper pan size. Always use
DO NOT USE WATER, including
~
~
cookware appropriate for the size of the
surface element.
wet dishcloths or towels - a violent
steam explosion may result.
Use a fire extinguisher
~
ONLY if:
– You have a Class ABC extinguisher
and know how to operate it.
– The fire is small and contained in the
area where it started.
– The fire department has been called.
– You can fight the fire with your back
to an exit.
5
Download from Www.Somanuals.com. All Manuals Search And Download.
IMPORTANT SAFETY INSTRUCTIONS
Installation
Any fittings, sealant, or materials
~
used to install the ductwork must be
, WARNING
~
To reduce the risk of fire only use
made of approved non-flammable
materials.
metal ductwork.
Never connect an exhaust hood to
~
Provided a larger distance is not
~
an active chimney, dryer vent, vent flue,
or room ventilating ductwork. Seek
professional advice before connecting
an exhaust hood vent to an existing,
inactive chimney or vent flue.
given by the manufacturer of the
cooktop, follow the minimum safety
distances between a cooktop and the
bottom of the hood:
– 22" (550 mm) above electric
cooktops,
Ducted fans must always be vented
~
outdoors.
– 30" (762 mm) above gas cooktops,
Make sure that the airflow in the
~
– 26" (650 mm) above an open electric room is sufficient for combustion and
grill or an open electric boiler/fryer.
exhausting of all non-electric heating
appliances (water heaters, gas
cooktops, gas ovens, etc.), otherwise
backdrafts may occur. Follow the
heating manufacturer’s guidelines and
safety standards or those published by
the National Fire Protection Association
(NFPA) or the American Society for
Heating, Refrigeration and Air
If local building codes require a greater
safety distance, follow their
requirement.
If there is more than one appliance
beneath the hood and they have
different minimum safety distances
always select the greater distance.
Conditioning Engineers (ASHRAE).
If in doubt, consult an experienced
professional.
Be careful not to damage hidden
~
electrical wiring or plumbing when
cutting or drilling into the wall or ceiling.
Do not use an extension cord to
~
connect the appliance to electricity.
Extension cords do not guarantee the
required safety of the appliance,
(e.g. danger of overheating).
Do not install this hood over
~
cooktops burning solid fuel.
6
Download from Www.Somanuals.com. All Manuals Search And Download.
Functional description
The ventilation hood works by air
extraction. The air is drawn in and
cleaned by the grease filter and
directed outside.
The hood comes equipped with a
non-return flap. This flap automatically
closes when the hood is turned off so
that no exchange of outside air and
room air can occur. When the hood is
turned on, the air pressure of the
exhaust fan automatically opens the
flap blowing the inside air and cooking
odors outside.
7
Download from Www.Somanuals.com. All Manuals Search And Download.
Guide to the appliance
8
Download from Www.Somanuals.com. All Manuals Search And Download.
Guide to the appliance
a Chimney extension
b Chimney
k Indirect light button
l Overhead light button
This button turns the light on and off
and also dims the light.
c Canopy
The lighting can be used independently
of the fan.
d Grease filter
e Overhead lighting
f Recirculation vent
g Indirect lighting
m On/Off button
n Fan power level buttons
Four fan speed selection.
o Delayed Shut Down
h Glass shelves
This button activates the Delayed Shut
Down feature. The fan can be set to
turn off automatically after either 5 or
15 minutes.
Each holds up to 8 lbs.
i Canopy storage surface
Max weight on entire surface not to
exceed 17 lbs.
p Grease filter button
The indicator next to the grease filter
button lights when the grease filters
need to be cleaned. This button is also
used:
j Control panel
– to reset the grease filter timer after
cleaning the grease filters (see
"Cleaning and Care").
– to show how long the grease filters
have been in use (see "Operation /
Grease filter timer").
– to change the number of hours
counted by the grease filter timer
(see "Operation / Reprogramming the
grease filter timer").
9
Download from Www.Somanuals.com. All Manuals Search And Download.
Operation
Turning on the fan
Automatically switching back the
Intensive power level
The intensive level "4" can be
programmed to automatically switch
back to level "3" after 10 minutes.
^ Press the On/Off button.
^ Turn the fan and the lights off.
The fan runs at power level "2".
The On/Off indicator lights.
Selecting the power level
^ Press and hold the Delay Shut Down
button for 10 secs. The first indicator
of the fan power levels lights.
^ Press the following buttons one after
another,
^ Use the "–/+" controls to select the
desired power level.
+ = increases the fan speed
– = decreases the fan speed
Level "1" to "3" (green indicators) are
usually sufficient for normal cooking.
– the right light button,
Intensive setting
Level "4" (yellow indicator) should be
used for a short period when frying or
cooking food with a strong aroma.
– the "–" button, and
– the right light button again.
10
Download from Www.Somanuals.com. All Manuals Search And Download.
Operation
Fan performance
The maximum air flow capacity is
625 cfm. Factors such as narrow duct
diameter and bends will affect this
value.
If the power level indicators "1" and "4"
flash the automatic switch back is not
activated.
Level 1 operates at 40% capacity
Level 2 operates at 60% capacity
Level 3 operates at 80% capacity
Level 4 operates at 100% capacity
^ To activate the automatic switch back
press the "+" button.
The power level indicators "1" and "4"
light.
^ To deactivate the automatic switch
back press the "–" button.
^ To save the setting press the Delay
Shut Down button.
If the procedure is not stored within
4 minutes of programming, the hood
will automatically default to the "old"
data.
11
Download from Www.Somanuals.com. All Manuals Search And Download.
Operation
Delayed Shut Down
Turning off the fan
If odors or smoke remain in the kitchen
after cooking has been completed, the
Delayed Shut Down feature can be
selected to allow the hood to continue
running for either 5 or 15 minutes.
^ Press the On/Off button to turn the
fan off.
The indicator goes out.
Automatic Safety Shut Off
^ Press the Delayed Shut Down button
while the fan is still running.
The fan will be turned off automatically
10 hours after the last button was
activated. The lighting however, will
remain on.
Press once = 5 minute delay
(left indicator lights)
Press twice = 15 minute delay
(right indicator lights)
^ Pressing the On/Off button will turn
the fan back on.
To cancel the Delayed Shut Down
feature press the button again.
12
Download from Www.Somanuals.com. All Manuals Search And Download.
Operation
Turning the lighting on / off
Dimming the lighting
The overhead lighting can be turned on The brightness of the lighting can be
and off independently of the fan.
adjusted.
^ While the lighting is turned on, press
the right light button.
The lighting will dim until the button is
released.
^ Press the light button briefly to turn
on the lighting.
^ If the button is pressed again, the
lighting will brighten until the button is
released.
The light button indicator illuminates.
If the button is pressed continuously,
the light will cycle between bright and
dark.
^ Press the light button briefly again to
turn off the lighting.
The light button indicator will go out.
^ Press the light button again to turn off
the lighting.
Indirect lighting
^ Turn the indirect lighting on and off
with the left light button.
^ The indirect lighting can be operated
independently from the fan.
13
Download from Www.Somanuals.com. All Manuals Search And Download.
Operation
Grease filter timer
Checking the grease filter timer
A timer monitors the hours of fan
operation. The indicator for the grease
filter will light after 30 hours of
operation. The grease filters must then
be cleaned.
To check the percentage of time
already used:
After the grease filters have been
cleaned and put in place, the grease
filter timer must be reset.
^ Press the On/Off button to turn the
fan on.
^ To do this, press the grease filter
button for about 3 seconds.
^ Press the grease filter button.
The indicator will go out.
The number of flashing "–/+" indicators
show the percentage of programmed
hours that have been used.
1 indicator = less than 25 %
2 indicators = less than 50 %
3 indicators = less than 75 %
4 indicators = less than 100 %
This information will remain stored in
memory in the event of a power failure.
14
Download from Www.Somanuals.com. All Manuals Search And Download.
Operation
Reprogramming the grease filter
timer
The grease filter timer is preset to 30
hours. This time can be lengthened or
shortened to 20, 30, 40 or 50 hours.
The indicator for the grease filter and
one of the "–/+" indicators will flash.
– A time of 20 hours should be
programmed in kitchens with
frequent pan or deep frying.
The lit "–/+" indicator shows the
programmed time:
1st indicator from the left = 20 hours
2nd indicator from the left = 30 hours
3rd indicator from the left = 40 hours
4th indicator from the left = 50 hours.
– A time of 20 hours should also be
programmed if the kitchen is only
used occasionally. Otherwise grease
which has accumulated over a long
period of time will harden on the
filters making cleaning more difficult.
^ Use the "–/+" buttons to select the
desired time.
^ Press the On/Off button to turn off the
fan.
^ Store the selection by pressing the
grease filter button.
If the procedure is not stored within
4 minutes of programming, the hood
will automatically default to the "old"
data.
^ Press the Delayed Shut Down and
grease filter buttons at the same time.
15
Download from Www.Somanuals.com. All Manuals Search And Download.
Cleaning and Care
Stainless steel
Before cleaning or servicing the
hood, disconnect it from the power
supply by either removing the fuse,
unplugging it from the outlet or
manually "tripping" the circuit
breaker.
Stainless steel surfaces can be cleaned
using a non-abrasive stainless steel
cleaner.
To help prevent resoiling, a conditioner
for stainless steel can also be used.
Apply sparingly with even pressure.
Cleaning the casing
Stainless steel colored controls
,Never use abrasive cleaners,
scouring pads, steel wool or caustic
(oven) cleaners on the hood. They
will damage the surface.
These controls may become
discolored or damaged if not
cleaned regularly.
Do not use a stainless steel cleaner
on these controls.
^ All external surfaces and controls can
be cleaned with warm water and
liquid dish soap applied with a soft
sponge.
^ Wipe dry using a soft cloth.
Do not use too much water when
cleaning the controls. Water could
penetrate into the electronics and
cause damage.
^ Glass surfaces can be cleaned using
glass cleaner.
Avoid:
– cleaning agents containing soda,
acids or chlorides,
– abrasive cleaning agents
e.g. powder or cream cleansers,
– abrasive sponges, e.g. pot scourers
or sponges which have been
previously used with abrasive
cleaning agents,
– limescale removers.
These will damage the surface.
16
Download from Www.Somanuals.com. All Manuals Search And Download.
Cleaning and Care
Grease filters
^ In a dishwasher: place the filters
vertically in the lower basket, making
sure that the spray arm is not
blocked.
The reusable metal grease filters
remove solid particles from the vented
kitchen air (grease, dust, etc).
Use a hot temperature program, e.g.
"Heavy Soil" or "Pots and pans".
Use the recommended amount of
dishwasher detergent. Overuse could
destroy the filter.
The grease filters should be cleaned
every 3 - 4 weeks or whenever the
grease filter indicator lights.
Depending on the detergent,
cleaning the grease filters in a
dishwasher may cause permanent
discoloration of the filter surface.
Performance of the filter will not be
affected by this discoloration.
A dirty filter is a fire hazard.
^ After cleaning, the filters can be
placed on a towel to air dry.
^ While the filters are removed, clean
any dirt or grease from the filter
casing to prevent the risk of fire.
When putting the grease filters back
make sure that the locking clips are
visible facing down towards the
cooking surface.
^ To remove the grease filters pull the
locking clips, 1, forward. Lower the
filter 45°, 2, unhook it at the rear, 3,
and take it out. Support the grease
filter so that it does not fall onto the
cooktop.
If the filters are incorrectly installed,
insert a small screwdriver into the slit
along its edge to disengage it from the
casing.
^ After returning the grease filters,
press the grease filter button for
3 seconds to reset the timer. The
indicator light will go out.
Cleaning the grease filters
^ By hand: use a scrub brush with a
solution of warm water and mild
detergent.
^ If the grease filters are cleaned
before the grease filter timer has
reached its maximum, the grease
filter button should be pressed for
6 seconds to reset the counter to
zero.
Do not use the pure detergent,
aggessive all purpose cleaners, oven
sprays or limescale removers. They
could destroy the filters.
17
Download from Www.Somanuals.com. All Manuals Search And Download.
Cleaning and Care
Changing the light bulbs
Overhead light
Before changing the light bulbs,
disconnect the hood from the power
supply by either removing the fuse,
unplugging it, or manually "tripping"
the circuit breaker.
When in use halogen bulbs become
extremely hot, and they can burn
your hands. Do not attempt to
change the bulbs until they have
had sufficient time to cool.
Do not touch the bulb surface.
Fingerprints or body oils deposited
on the bulb will decrease the life of
the bulb. Please follow the bulb
manufacturer’s instructions.
^ To change the halogen bulb, remove
the lamp cover, a, pull the bulb, b,
out of its socket and replace with a
new one.
^ Return the lamp cover, a.
Never use the lighting without the
lamp cover, a, in place. The glass
is specially made to filter harmful
light rays.
18
Download from Www.Somanuals.com. All Manuals Search And Download.
Cleaning and Care
Indirect lighting
^ Remove the two screws securing the
light cover.
^ Carefully raise the front of the bulb
and pull it out of its socket.
^ Insert the new bulb into the socket
and lower it into its holder.
^ Replace the light cover and the two
screws.
19
Download from Www.Somanuals.com. All Manuals Search And Download.
After Sales Service
Repairs
MieleCare
In the event of a fault which you cannot
easily fix yourself, please contact the
Miele Technical Service Department.
MieleCare, our Extended Service
Contract program, gives you the
assurance of knowing that your
appliance investment is covered by
5 years of worry free ownership.
MieleCare is the only Extended Service
Contract in the industry that guarantees
repairs by a Miele Authorized Service
Provider using genuine Miele parts.
Only genuine Miele parts installed by
factory trained professionals can
guarantee the safety, reliability, and
longevity of your Miele appliance.
^ When contacting the Technical
Service Department, please quote
the model and serial number of your
appliance.
These are shown on the data plate
which is visible when the grease filters
are removed.
Please note that unless expressly
approved in writing by Miele’s Service
department, Extended Service
Contracts offered by other providers for
Miele products will not be recognized
by Miele. Our goal is to prevent
unauthorized (and untrained) service
personnel from working on your Miele
products, possibly doing further
damage to them, you and/or your
home.
To learn more about MieleCare
Extended Service Contracts, please
contact your appliance dealer or visit
us online at:
20
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation Instructions
Download from Www.Somanuals.com. All Manuals Search And Download.
22
Download from Www.Somanuals.com. All Manuals Search And Download.
Caring for the environment
Disposal of packing material
Disposal of an old appliance
The cardboard box and packing
materials protect the appliance during
shipping. They have been designed to
be biodegradable and recyclable.
Please recycle.
Old appliances may contain materials
that can be recycled. Please contact
your local recycling center about the
possibility of recycling these materials.
Before discarding an old hood,
unplug it from the outlet and cut off
its power cord to prevent hazards.
To prevent suffocation of children,
ensure that any plastic wrappings,
bags, etc. are disposed of safely
and kept out of their reach.
23
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation accessories
24
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation accessories
a
3 protective shields
prevent scratches to the chimney
during installation.
4 screws 5 x 60 mm
4 washers 5.3 mm
b Upper retaining plate for
securing the chimney extension.
c
d
e
1 diverter
1 flexible hose
2 hose clips for securing the
6 screws 5 x 40 mm
exhaust ducting.
(The wall anchors included in the
packaging are not for use in
USA/CDN).
f Middle retaining plate for
securing the chimney extension.
g Lower retaining plate for
securing the canopy.
h
2 charcoal filters DKF 6
2 M 6 locking nuts for securing the
motor assembly.
4 screws 3.9 x 7.5 mm for securing the
chimney and the chimney extension.
Installation instruction sheet
CAUTION:
During the installation process
please be careful of sharp edges
that can cause harm.
25
Download from Www.Somanuals.com. All Manuals Search And Download.
Plywood backing
^ Find the studs to the left and right of
the mounting location by tapping the
wall or using a stud finder.
The majority of the weight of the
installed ventilation system will be
supported by the canopy. Its
mounting bracket must be firmly
attached to the stud framing behind
the drywall. If studs are not located
in the required locations, a plywood
^ Mark the center of each of the studs
with a vertical line.
Be careful not to damage any wiring
or plumbing that may be located
behind the wall. Make sure that the
power supply to the area being
worked in has been turned off at the
breaker panel before cutting into the
wall.
½
backing (min. " (13 mm) thick)
spanning at least two studs must be
installed. Failure to adequately
support the weight as stated may
result in the ventilation system falling
off the wall, causing personal injury
and property damage.
^ Cut out the drywall along the marked
lines and replace it with plywood of a
½
matching thickness (min. " (13 mm)
(If plywood backing is not needed,
proceed to "Appliance dimensions and
Installation").
thick). Tape the joints and refinish the
wall.
^ See enclosed installation sheet for
instructions on how to install the
appliance.
To install a plywood backing board
^ Determine and mark the location of
the retaining plate for the canopy as
outlined on the Installation sheet.
^ Make a cutting line 3" (76 mm) above
and 3" (76 mm) below the outline of
the retaining plate.
26
Download from Www.Somanuals.com. All Manuals Search And Download.
Electrical data
Grounding Instructions
All electrical work should be
performed by a qualified electrician
in strict accordance with national
and local safety regulations.
Installation, repairs and other work
by unqualified persons could be
dangerous. The manufacturer
cannot be held responsible for
unauthorized work.
This appliance must be grounded. In
the event of an electrical short circuit,
grounding reduces the risk of electric
shock by providing a path of least
resistance. This appliance is equipped
with a cord having a grounding wire
with a grounding plug. The plug must
be plugged into an outlet that is
properly installed and grounded.
Ensure that power to the appliance
is OFF while installation or repair
work is performed.
WARNING - Improper grounding can
result in a risk of electric shock.
If there is any doubt, have the electrical
system of the house checked by a
qualified electrician. The manufacturer
cannot be held responsible for
damages caused by the lack, or
inadequacy, of an effective grounding
system.
^ Verify that the voltage, load and
circuit rating information found on the
data plate (located behind the
grease filters), match the household
electrical supply before installing the
hood.
^ Use only with rangehood
Do not use an extension cord. If the
power supply cord is too short, have a
qualified electrician install an outlet
near the appliance.
cord-connection kits that have been
investigated and found acceptable
for use with this model rangehood.
If there is any question concerning the
electrical connection of this appliance
to your power supply, please consult a
licensed electrician or call Miele’s
Technical Service Department.
Important
The hood comes equipped with a 4 ft
(1.2 m) power cord with a NEMA 5-15
molded plug for connection to a
U
V
1-800-999-1360
1-800-565-6435
120 VAC, 60 Hz, 15 A power outlet.
Maximum load DA 252-4 . . . . . . 456 W
DA 251-4, DA 259-4 . . . . . . . . . . 436 W
WARNING:
THIS APPLIANCE MUST BE
GROUNDED
Lighting DA 252-4 . . . . . . . . . 4 x 20 W
DA 251-4, DA 259-4 . . . . . . . . 3 x 20 W
Indirect lighting . . . . . . . . . . . . 2 x 13 W
Voltage . . . . . . . . . . . . . . . . . . . . . 120 V
Frequency . . . . . . . . . . . . . . . . . . 60 Hz
Circuit rating. . . . . . . . . . . . . . . . . . 15 A
27
Download from Www.Somanuals.com. All Manuals Search And Download.
Appliance dimensions and Installation
28
Download from Www.Somanuals.com. All Manuals Search And Download.
Appliance dimensions and Installation
1) and 2) Cut out area in wall or
Distance between cooktop and
hood (S)
ceiling for entrance of 6"
(150 mm) ductwork or 5"
(125 mm) ductwork with a reducing
collar.
The installation procedure differs
depending on the model and venting
method.
Before beginning the installation:
Do not install this exhaust hood over
cooktops burning solid fuel.
^ Read all instructions.
^ Determine height (S), regarding the
user’s body height, i.e. a comfortable
height for the user.
Provided a larger distance is not
given by the manufacturer of the
cooktop, follow the minimum safety
distances between a cooktop and
the bottom of the hood:
However, the greater the distance,
the less effectively cooking odors are
drawn in.
- 22" (550 mm) above electric
cooktops,
^ If the hood is fitted flush to the ceiling
make sure that the remaining
- 30" (762 mm) above gas cooktops,
- 26" (650 mm) above an open
electric grill or an open electric
boiler/fryer.
distance to the ceiling is not greater
or less than appliance height (H).
If the standard unit height H is not
suitable for the kitchen’s ceiling height,
longer optional chimney extensions are
available from your Miele dealer or
Miele’s Technical Service Department.
If local building codes require a
greater safety distance, follow their
requirement.
If there is more than one appliance
beneath the hood and they have
different minimum safety distances
always select the greater distance.
Standard unit H
29 1/8" - 44 7/8"
(740 - 1140 mm)
To fit the lower chimney section, the
distance between the top of the
chimney and the ceiling must be at
least 7/8" (20 mm).
See "Important Safety Instructions"
for further information.
29
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation
Installation instructions
^ See the enclosed installation
instruction sheet.
^ Please read the "Important Safety
Instructions" and Installation
instructions before installing this
hood.
Protective film
The casing is covered with a protective
film to prevent scratching during
transport.
^ Peel off the film before installing the
casing parts.
30
Download from Www.Somanuals.com. All Manuals Search And Download.
Air extraction
Exhaust ducting and connections
,WARNING
– The ducting should be as short and
straight as possible, and the number
of sharp bends should be minimized.
Danger of toxic fumes.
Gas cooking appliances release
carbon monoxide that can be
harmful or fatal if inhaled.
– For most efficient air extraction, the
diameter of the ductwork should not
be less than 6" (150 mm). Use of flat
ducts also reduces the air extraction
efficiency.
The exhaust gases extracted by
the hood should be vented
outside of the building only.
– Noise levels of the hood will increase
if flat ducts or round ducts of less
than 6" (150 mm) in diameter are
used.
Do not terminate the exhaust
ducts in attics, garages,
crawlspaces, etc.
– Use smooth or flexible pipes made
from approved non-flammable
materials for exhaust ducting.
To reduce the risk of fire, only use
metal ductwork.
– Where the ductwork is horizontal, it
must slope away from the hood at
least 1/8" per foot (1 cm per meter) to
prevent condensation dripping into
the appliance.
Please read and follow the
"IMPORTANT SAFETY
INSTRUCTIONS" to reduce the risk of
personal injury. Follow all local building
codes when installing the hood.
– If the exhaust is ducted through an
outside wall, a Miele Telescopic Wall
Vent can be used.
31
Download from Www.Somanuals.com. All Manuals Search And Download.
Air extraction
Condensate trap
optional accessory
– If the exhaust is ducted into an
inactive flue, the air must be expelled
parallel to the flow direction of the
flue.
In some cases, a condensate trap may
also be required to collect and
evaporate any condensate which may
occur. This optional accessory is
available for ducts 5" (125 mm) and
5 7/8" (150 mm) in diameter.
Never connect an exhaust hood to
an active chimney, dryer vent, flue,
or room venting ductwork. Seek
professional advice before
connecting an exhaust hood vent to
an existing, inactive chimney or vent
flue.
^ When installing a condensate trap,
ensure that it is positioned vertically
and if possible directly above the
exhaust outlet.
Important
If the ductwork runs through rooms,
ceilings, garages, etc. where
temperature variations exist, it may
need to be insulated to reduce
condensation.
32
Download from Www.Somanuals.com. All Manuals Search And Download.
33
Download from Www.Somanuals.com. All Manuals Search And Download.
34
Download from Www.Somanuals.com. All Manuals Search And Download.
35
Download from Www.Somanuals.com. All Manuals Search And Download.
Alteration rights reserved / 4607
M.-Nr. 06 712 760 / 03
For most the updated manual see the Miele web site.