MICRONIX PC/104
POWER SUPPLY
PV-5120, 22 & 24
POWER SUPPLY MODULE WITH UPS
AND UP TO 3.84 MB SSD FLASH
PC/104-MODULES
User Manual
&
Installation Guide
VERS. 1.02
DOC: M5124DM.DOC
Micro Technic A-S • Denmark •
Tel. +45 6615 3000 • Fax +45 6615 3077
E-mail: [email protected]
Website: www.micro-technic.com
Download from Www.Somanuals.com. All Manuals Search And Download.
Users Manual & Installation Guide
PV- SERIES: Power supply module with UPS and SSD Flash
FEATURES AND SPECIFICATIONS
Power Supply
• Output power capability:
30W(max)
8-30 VDC or
• Input voltage:
16-30 VDC using battery charger for 12V battery
+5V @5A (max)
• Output voltage:
+12V @250mA(max)
-12V @100mA(max)
• Line regulation(+5V)
• Load regulation(+5V)
• Load regulation(+12V)
• Load regulation(-12V)
• Ripple/noise:
0.3% - @low line to high line; full load
0.6% - @no load to full load; nominal input
1% - @no load to full load; nominal input
0.5% - @no load to full load; nominal input
150mV p-p; DC–20MHz
• LED indicators:
Green LED indicating presence of +5V
Green LED indicating presence of +12V
Green LED indicating presence of -12V
Green LED indicating Mains>16V
Battery charger
• Supported battery-type:
• Charging method:
• Charging current:
• LED indicators:
•
12V lead-acid, min. 4AH
Constant current / constant voltage
400mA
Yellow LED indicating “Battery full”
Red LED indicating “Battery low”
UPS
• Alarm outputs:
“Mains failure” alarm interrupt
•
“Battery low” alarm interrupt
• Interrupt support:
• Automatic shut down:
•
INT 5,7,9,10,11,12,15 – programmable
120 sec after detection of both:
“Mains failure” and “Battery low”
• CPU controlled shut down:
Controlled by user-software, delayed up to 127 sec.
SSD
• Disk capacity:
PV-5122: 1.76 MB
•
PV-5124: 3.84 MB
• Speed:
PV5122: Read 170 KB/sec, write 20 KB/sec
PV5124: Read 90 KB/sec, write 15 KB/sec
•
Physical / Environment
• Dimensions:
96x90x18mm
• Temperature range:
Operating: -20°C to 70°C
•
Storage:
-40°C to +85°C
• Humidity:
• Connectors
•
0 to 90% RH, non-condensing
PC/104 Stack-through connectors
Screw terminals for mains and 12V battery
Page 3 of 8
Download from Www.Somanuals.com. All Manuals Search And Download.
Users Manual & Installation Guide
PV- series: Power supply module with UPS and SSD Flash
MODEL SELECTION
PV - 512XY-S
Disk capacity
0=No SSD
2=1.76 MB
4=3.84 MB
A = without UPS
and battery charger
S = Stack-through
AVAILABLE MODELS
Model no.
PV-5120-S
PV-5122-S
Description/Type
PS with UPS, Stack-through
PS with UPS and 1.76 MB SSD,
Stack-through
PV-5124-S
PS with UPS and 3.84 MB SSD,
Stack-through
PV-5120A-S
PS, Stack-through, without UPS and
battery charger.
Page 4 of 8
Download from Www.Somanuals.com. All Manuals Search And Download.
Users Manual & Installation Guide
PV- SERIES: Power supply module with UPS and SSD Flash
INSTALLATION GUIDE
PRECAUTIONS TO ESD
Please note, that the Micronix PV modules must be handled with respect to ESD (Electrostatic
Discharge). Electrostatic Discharge to the PV modules must be avoided.
Before removing the module from the protection bag, the user must be discharged using a grounded
wrist ribbon.
SCHEMATIC OUTLINE
Page 5 of 8
Download from Www.Somanuals.com. All Manuals Search And Download.
Users Manual & Installation Guide
PV- series: Power supply module with UPS and SSD Flash
I/O MAP AND MEMORY MAP
I/O Map
I/O port range used is 250h-257h. Be sure that no other hardware in the system makes use of this I/O
range.
Memory Map
PV-5120 uses no memory range.
PV-5122 & PV5124 uses memory range D0000h-D7FFFh.
Be sure that no other hardware in the system makes use of this memory range. If your system BIOS
set-up has ROM BIOS shadowing functions, you may enable shadowing in the D0000h-D3FFFh range
to improve flashdisk performance. You should not enable shadowing in the D4000h-D7FFFh range. If
your system BIOS only allows to enable/disable shadowing in the whole D0000h-D7FFFh range, you
must disable it.
Page 6 of 8
Download from Www.Somanuals.com. All Manuals Search And Download.
Users Manual & Installation Guide
PV- SERIES: Power supply module with UPS and SSD Flash
SCHEMATIC
Page 7 of 8
Download from Www.Somanuals.com. All Manuals Search And Download.
Users Manual & Installation Guide
PV- series: Power supply module with UPS and SSD Flash
UPS TIMING
Typical discharge/charge
Short time dropout of mains
Page 8 of 8
Download from Www.Somanuals.com. All Manuals Search And Download.
|