ElECTRIC DRYER InSTAllATIon InSTRuCTIonS  
27" WIDE moDElS - u.S.A. onlY  
Para obtener acceso al manual de uso y cuidado en español, o para obtener información adicional acerca de su producto, visite:  
Tenga listo su número de modelo completo. Puede encontrar el número de modelo y de serie dentro de la cavidad superior de la puerta.  
Table of Contents  
DRYER SAFETY .........................................................................2  
InSTAllATIon REquIREmEnTS.............................................3  
Tools and Parts ......................................................................3  
location Requirements.........................................................3  
Electrical Requirements........................................................4  
Install leveling legs..............................................................6  
Electrical Connection ............................................................7  
VEnTInG...................................................................................13  
Venting Requirements .........................................................13  
Plan Vent System .................................................................14  
Venting Kits ..........................................................................14  
Install Vent System ..............................................................15  
Connect Vent........................................................................15  
level Dryer ...........................................................................16  
Complete Installation Checklist .........................................16  
Reverse Door Swing (optional) ..........................................17  
Troubleshooting ...................................................................18  
W10096988A  
W10306460A-SP  
Download from Www.Somanuals.com. All Manuals Search And Download.  
InSTAllATIon REquIREmEnTS  
Parts supplied:  
Tools and Parts  
Gather the required tools and parts before starting installation.  
Read and follow the instructions provided with any tools listed  
here.  
Tools needed:  
Leveling legs (4)  
Parts package is located in dryer drum. Check that all parts  
are included.  
Parts needed:  
Check local codes. Check existing electrical supply and venting,  
and read “Electrical Requirements” and “Venting Requirements”  
before purchasing parts.  
Flat-blade screwdriver  
#2 Phillips screwdriver  
Mobile home installations require metal exhaust system  
hardware, available for purchase from the dealer from whom  
you purchased your dryer. For further information, please  
reference the “Assistance or Service” section of the Dryer  
User Instructions.  
If using a power supply cord:  
Wire stripper  
Tin snips  
(direct wire installations)  
(new vent installations)  
Use a UL listed power supply cord kit marked for use with  
clothes dryers. The kit should contain:  
A UL listed 30-amp power supply cord, rated 120/240 volt  
minimum. The cord should be type SRD or SRDT and be  
at least 4 ft. (1.22 m) long. The wires that connect to the  
dryer must end in ring terminals or spade terminals with  
upturned ends.  
A UL listed strain relief.  
1/4" nut driver  
(recommended)  
Vent clamps  
location Requirements  
Adjustable wrench that  
opens to 1" (25 mm) or  
hex-head socket wrench  
Utility knife  
Tape measure  
Pliers  
You will need:  
A location allowing for proper exhaust installation.  
See “Venting Requirements.”  
A separate 30 amp circuit.  
Level  
Caulking gun and  
compound (for installing  
new exhaust vent)  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
If you are using power supply cord, a grounded electrical  
outlet located within 2 ft. (610 mm) of either side of dryer.  
See “Electrical Requirements.”  
minimum Required Spacing  
3"*  
(76 mm)  
14" max.*  
(356 mm)  
2
A sturdy floor to support the total weight (dryer and load)  
of 200 lbs. (90.7 kg). The combined weight of a companion  
appliance should also be considered.  
48 in.  
*
(310 cm )2  
18"*  
(457 mm)  
Level floor with maximum slope of 1" (25 mm) under entire  
dryer. (If slope is greater than 1" [25 mm], install Extended  
Dryer Feet Kit, Part Number 279810.) If not level, clothes  
may not tumble properly and automatic sensor cycles may  
not operate correctly.  
2
*
24 in.  
(155 cm )  
3"*  
(76 mm)  
2
27"  
(686 mm)  
1"  
(25 mm)  
1"*  
(25 mm)  
1"  
(25 mm)  
29 ¼"  
(743 mm) (140 mm)  
5 ½"*  
Do not operate your dryer at temperatures below 45°F (7°C). At  
lower temperatures, the dryer might not shut off at the end of an  
automatic cycle. Drying times can be extended.  
B
C
A
A. Recessed area  
B. Side view - closet or confined area  
C. Closet door with vents  
The dryer must not be installed or stored in an area where it will  
be exposed to water and/or weather.  
*Additional spacing recommended  
Check code requirements. Some codes limit, or do not permit,  
installation of the dryer in garages, closets, mobile homes, or  
sleeping quarters. Contact your local building inspector.  
mobile home - Additional installation requirements  
This dryer is suitable for mobile home installations. The  
installation must conform to the Manufactured Home  
Construction and Safety Standard, Title 24 CFR, Part 3280  
(formerly the Federal Standard for Mobile Home Construction  
and Safety, Title 24, HUD Part 280).  
Installation clearances:  
The location must be large enough to allow the dryer door  
to open fully.  
Dryer Dimensions  
Metal exhaust system hardware, which is available for  
purchase from your dealer.  
23¾"  
(603 mm)  
Special provisions must be made in mobile homes to  
introduce outside air into the dryer. The opening (such  
as a nearby window) should be at least twice as large  
as the dryer exhaust opening.  
43"  
43"  
(1092 mm)  
(1092 mm)  
13¾"  
(349 mm)  
Electrical Requirements  
It is your responsibility:  
*291/2"  
*291/2"  
(749 mm)  
(749 mm)  
27"  
27"  
(687 mm)  
(687 mm)  
To contact a qualified electrical installer.  
A
B
To be sure that the electrical connection is adequate and in  
conformance with the National Electrical Code, ANSI/NFPA  
70-latest edition and all local codes and ordinances.  
A. Large opening side-swing door  
B. Wide opening hamper door  
*Most installations require a minimum 5½" (140 mm) clearance  
behind the dryer for the exhaust vent with elbow. See “Venting  
Requirements.”  
The National Electrical Code requires a 4-wire power supply  
connection for homes built after 1996, dryer circuits involved  
in remodeling after 1996, and all mobile home installations.  
minimum spacing for recessed area or  
A copy of the above code standards can be obtained from:  
National Fire Protection Association, One Batterymarch Park,  
Quincy, MA 02269.  
closet installation  
The dimensions shown following are for the minimum spacing  
allowed.  
To supply the required 3 or 4 wire, single phase, 120/240 volt,  
60 Hz, AC only electrical supply (or 3 or 4 wire, 120/208 volt  
electrical supply, if specified on the serial/rating plate) on a  
separate 30-amp circuit, fused on both sides of the line. A  
time-delay fuse or circuit breaker is recommended. Connect  
to an individual branch circuit. Do not have a fuse in the  
neutral or grounding circuit.  
Additional spacing should be considered for ease of  
installation and servicing.  
Additional clearances might be required for wall, door, and  
floor moldings.  
Additional spacing of 1" (25 mm) on all sides of the dryer is  
recommended to reduce noise transfer.  
Do not use an extension cord.  
For closet installation, with a door, minimum ventilation  
openings in the top and bottom of the door are required.  
Louvered doors with equivalent ventilation openings  
are acceptable.  
If codes permit and a separate ground wire is used, it is  
recommended that a qualified electrician determine that the  
ground path is adequate.  
Companion appliance spacing should also be considered.  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
If connecting by direct wire:  
Electrical Connection  
Power supply cable must match power supply (4-wire or 3-wire)  
and be:  
To properly install your dryer, you must determine the type of  
electrical connection you will be using and follow the instructions  
provided for it here.  
Flexible armored cable or nonmetallic sheathed copper cable  
(with ground wire), covered with flexible metallic conduit. All  
current-carrying wires must be insulated.  
If local codes do not permit the connection of a neutral  
ground wire to the neutral wire, see “Optional 3-wire  
connection” section.  
10-gauge solid copper wire (do not use aluminum).  
At least 5 ft. (1.52 m) long.  
This dryer is manufactured ready to install with a 3-wire  
electrical supply connection. The neutral ground wire is  
permanently connected to the neutral conductor (white wire)  
within the dryer. If the dryer is installed with a 4-wire electrical  
supply connection, the neutral ground wire must be removed  
from the external ground connector screw (green screw), and  
secured under the neutral terminal (center or white wire) of  
the terminal block. When the neutral ground wire is secured  
under the neutral terminal (center or white wire) of the terminal  
block, the dryer cabinet is isolated from the neutral conductor.  
A 4-wire power supply connection must be used when the  
dryer is installed in a location where grounding through the  
neutral conductor is prohibited. Grounding through the neutral  
is prohibited for (1) new branch-circuit installations, (2) mobile  
homes, (3) recreational vehicles, and (4) areas where local  
codes prohibit grounding through the neutral conductors.  
If using a power supply cord:  
Use a UL listed power supply cord kit marked for use with  
clothes dryers. The kit should contain:  
A UL listed 30-amp power supply cord, rated 120/240 volt  
minimum. The cord should be type SRD or SRDT and be  
at least 4 ft. (1.22 m) long. The wires that connect to the  
dryer must end in ring terminals or spade terminals with  
upturned ends.  
A UL listed strain relief.  
If your outlet looks like this:  
Then choose a 4-wire power supply cord  
with ring or spade terminals and UL listed  
strain relief. The 4-wire power supply cord,  
at least 4 ft. (1.22 m) long, must have  
4 10-gauge solid copper wires and match  
a 4-wire receptacle of NEMA Type 14-30 R.  
The ground wire (ground conductor) may be  
either green or bare. The neutral conductor  
must be identified by a white cover.  
4-wire receptacle  
(14-30R)  
If your outlet looks like this:  
Then choose a 3-wire power supply cord with  
ring or spade terminals and UL listed strain  
relief. The 3-wire power supply cord, at least  
4 ft. (1.22 m) long, must have 3 10-gauge solid  
copper wires and match a 3-wire receptacle of  
NEMA Type 10-30R.  
3-wire receptacle  
(10-30R)  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
Install leveling legs  
2.  
Screw in leveling legs  
WARNING  
Excessive Weight Hazard  
diamond  
marking  
Use two or more people to move and install dryer.  
Failure to do so can result in back or other injury.  
1.  
Prepare dryer for leveling legs  
Examine leveling legs, find diamond marking. Screw legs into  
leg holes by hand, use a wrench to finish turning legs until  
diamond marking is no longer visible.  
Now stand the dryer on its feet. Slide the dryer until it is  
close to its final location. Leave enough room for electrical  
connection and to connect the exhaust vent.  
To avoid damaging floor, use a large flat piece of cardboard  
from dryer carton; place under entire back edge of dryer.  
Firmly grasp dryer body (not console panel) and gently lay  
dryer down on cardboard.  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
Electrical Connection  
Power Supply Cord  
Direct Wire  
WARNING  
WARNING  
Fire Hazard  
Fire Hazard  
Use 10 gauge solid copper wire.  
use a new ul listed 30 amp power supply cord.  
use a ul listed strain relief.  
Use a UL listed strain relief.  
Disconnect power before making electrical connections.  
Disconnect power before making electrical connections.  
Connect neutral wire (white or center wire) to center  
terminal (silver).  
Connect neutral wire (white or center wire) to center  
terminal (silver).  
Ground wire (green or bare wire) must be connected to  
green ground connector.  
Ground wire (green or bare wire) must be connected to  
green ground connector.  
Connect remaining 2 supply wires to remaining  
2 terminals (gold).  
Connect remaining 2 supply wires to remaining  
2 terminals (gold).  
Securely tighten all electrical connections.  
Securely tighten all electrical connections.  
Failure to do so can result in death, fire, or  
electrical shock.  
Failure to do so can result in death, fire, or  
electrical shock.  
Electrical Connection options  
2.Remove terminal block cover  
1.Choose electrical connection type  
C
B
Power supply cord 4-wire receptacle  
(nEmA Type 14-30R): Go to steps 1-2 on  
page 8 for power supply cord strain relief:  
then steps 3-6 for 4-wire Power Supply  
Cord Connection section. Then, go to  
Venting Requirements.  
A
Power supply cord 3-wire receptacle  
(nEmA Type 10-30R): Go to steps 1-2 on  
page 8 for power supply cord strain relief:  
then steps 3-5 for 3-wire Power Supply  
Cord Connection section.  
D
E
Then go to Venting Requirements.  
F
4-wire direct connection: Go to steps  
1-2 on page 10 for direct wire strain re-  
lief: then steps 3-8 for 4-wire Direct Wire  
Connection section. Then go to Venting  
Requirements.  
Before you start, disconnect power. Remove hold-down  
screw (D) and terminal block cover (A).  
A. Terminal block cover  
B. External ground conductor screw  
C. Center, silver-colored terminal block screw  
D. Hold-down screw  
3-wire direct connection: Go to steps  
1-2 on page 10 for direct wire strain relief:  
then steps 3-7 for 3-wire Direct Wire  
Connection section. Then go to Venting  
Requirements.  
E. Neutral ground wire  
F. Hole below terminal block cover  
noTE: If local codes do not permit connection of a  
cabinet-ground conductor to neutral wire, go to “Optional  
3-wire Connection” section. This connection may be  
used with either a power supply cord or a direct wire  
connection.  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
Power Supply Cord Connection  
Power supply cord strain relief  
4-wire Power Supply Cord Connection  
Attach power supply cord  
strain relief  
ImPoRTAnT: A 4-wire connection is required for mobile  
homes and where local codes do not permit the use of 3-wire  
connections.  
1.  
A
B
B
F
A
C
D
E
C
D
G
A. 4-wire receptacle (NEMA type 14-30R)  
B. 4-prong plug  
C. Ground prong  
D. Neutral prong  
E. Spade terminals with upturned ends  
F. 3/4" (19 mm) UL listed strain relief  
G. Ring terminals  
Remove the screws from a 3/4" (19 mm) UL listed strain relief  
(UL marking on strain relief). Put the tabs of the two clamp  
sections (C) into the hole below the terminal block opening  
(B) so that one tab is pointing up (A) and the other is pointing  
down (D), and hold in place. Tighten strain relief screws just  
enough to hold the two clamp sections (C) together.  
Prepare to connect neutral  
ground wire and neutral wire.  
3.  
Attach power supply cord  
to strain relief  
2.  
E
B
A
Remove center, silver-colored terminal block screw (B).  
Remove neutral ground wire (E) from external ground  
conductor screw (A).  
Put power supply cord through the strain relief. Be sure that  
the wire insulation on the power supply cord is inside the  
strain relief. The strain relief should have a tight fit with the  
dryer cabinet and be in a horizontal position. Do not further  
tighten strain relief screws at this point.  
4. Connect neutral ground wire  
and neutral wire  
For 3-wire Power Supply Cord Connection, see page 8.  
For 4 wire Power Supply Cord Connection, continue to  
step 3 on this page.  
B
E
C
Connect neutral ground wire (E) and neutral wire (white or  
center) (C) of power supply cord under center, silver-colored  
terminal block screw (B). Tighten screw.  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
3-wire Power Supply Cord Connection  
5.Connect ground wire  
use where local codes permit connecting cabinet-ground  
conductor to neutral wire.  
E
B
D
A
C
F
G
A. 3-wire receptacle (NEMA type 10-30R)  
B. 3-wire plug  
C. Neutral prong  
D. Spade terminals with upturned ends  
E. 3/4" (19 mm) UL listed strain relief  
F. Ring terminals  
A
F
G. Neutral (white or center wire)  
Connect ground wire (F) (green or bare) of power supply cord  
to external ground conductor screw (A). Tighten screw.  
3.Remove center screw  
6. Connect remaining wires  
B
Remove center, silver-colored terminal block screw (B).  
4.Connect neutral wire  
Connect remaining wires to outer terminal block screws.  
Tighten screws. Finally, reinsert tab of terminal block cover  
into slot of dryer rear panel. Secure cover with hold-down  
screw. now, go to Venting Requirements.  
B
C
Connect neutral wire (white or center) (C) of power supply cord  
to center, silver-colored terminal block screw (B). Tighten screw.  
5.Connect remaining wires  
Connect remaining wires to outer terminal block screws.  
Tighten screws. Finally, reinsert tab of terminal block cover  
into slot of dryer rear panel. Secure cover with hold-down  
screw. now, go to Venting Requirements.  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
Direct Wire Connection  
Direct wire strain relief  
4-wire Direct Wire Connection  
ImPoRTAnT: A 4-wire connection is required for mobile  
homes and where local codes do not permit 3-wire  
connections.  
1.Attach direct wire strain relief  
A
3.Prepare your 4-wire cable for  
direct connection  
B
C
Unscrew the removable conduit connector (A) and any  
screws from a 3/4" (19 mm) UL listed strain relief (UL marking  
on strain relief). Put the threaded section of the strain relief  
(C) through the hole below the terminal block opening (B).  
Reaching inside the terminal block opening, screw the  
removable conduit connector (A) onto the strain relief threads.  
Direct wire cable must have 5 ft. (1.52 m) of extra length so  
dryer may be moved if needed.  
Strip 5" (127 mm) of outer covering from end of cable,  
leaving bare ground wire at 5" (127 mm). Cut 11/2" (38 mm)  
from remaining 3 wires. Strip insulation back 1" (25 mm).  
Shape ends of wires into hooks.  
2.Attach direct wire cable  
to strain relief  
4.Connect wires to terminal block  
To connect wires to terminal block, place hooked end of  
wire under terminal block screw, facing to the right, squeeze  
hooked end together and tighten screw.  
Put direct wire cable through the strain relief. The strain  
relief should have a tight fit with the dryer cabinet and be in  
a horizontal position. Tighten strain relief screw against the  
direct wire cable.  
5.Prepare to connect neutral  
ground wire and neutral wire  
For 3-wire Direct Wire Connection, see page 11.  
For 4 wire Direct Wire Connection, continue to step 3 on  
this page.  
E
B
A
Remove center, silver-colored terminal block screw (B).  
Remove neutral ground wire (E) from external ground  
conductor screw (A).  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3-wire Direct Wire Connection  
use where local codes permit connecting cabinet-ground  
conductor to neutral wire.  
6.Connect neutral ground wire  
and neutral wire  
B
C
3.Prepare your 3-wire cable for  
direct connection  
E
Connect neutral ground wire (E) and place hooked end (hook  
facing right) of neutral wire (white or center wire) (C) of direct  
wire cable under center screw of terminal block (B). Squeeze  
hooked ends together and tighten screw.  
Direct wire cable must have 5 ft. (1.52 m) of extra length so  
dryer may be moved if needed.  
Strip 31/2" (89 mm) of outer covering from end of cable. Strip  
insulation back 1" (25 mm). If using 3-wire cable with ground  
wire, cut bare wire even with outer covering. Shape wire ends  
into hooks.  
7.Connect ground wire  
4.Connect wires to terminal block  
To connect wires to terminal block, place hooked end of wire  
under terminal block screw, facing to the right, squeeze  
hooked end together and tighten screw.  
A
F
Connect ground wire (green or bare) (F) of direct wire cable  
to external ground conductor screw (A). Tighten screw.  
5.Remove center screw  
8.Connect remaining wires  
B
Remove center, silver-colored terminal block screw (B).  
Place hooked ends of remaining direct wire cable wires  
under outer terminal block screws (hooks facing right).  
Squeeze hooked ends together and tighten screws. Finally,  
reinsert tab of terminal block cover into slot of dryer rear  
panel. Secure cover with hold-down screw. now, go to  
Venting Requirements.  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2.  
Connect neutral ground wire  
and neutral wire  
6.Connect neutral wire  
B
B
C
E
C
Place hooked end of neutral wire (white or cente) (C) of direct  
wire cable under center terminal block screw (B). Squeeze  
hooked end together. Tighten screw.  
Connect neutral ground wire (E) and neutral wire (white or  
center wire) (C) of power supply cord or cable under center,  
silver-colored terminal block screw (B). Tighten screw.  
7. Connect remaining wires  
3. Connect remaining wires  
Place hooked ends of remaining direct wire cable wires  
under outer terminal block screws (hooks facing right).  
Squeeze hooked ends together and tighten screws. Finally,  
reinsert tab of terminal block cover into slot of dryer rear  
panel. Secure cover with hold-down screw. now, go to  
Venting Requirements.  
Place hooked ends of remaining wires under outer terminal  
block screws (hooks facing right). Tighten screws.  
4. Connect external ground wire  
optional 3-wire Connection  
You must verify with a qualified electrician that this  
grounding method is acceptable before connecting.  
1.Prepare to connect neutral  
ground wire and neutral wire  
E
B
A
G
Connect a separate copper ground wire (G) from the external  
ground conductor screw (A) to an adequate ground. Finally,  
reinsert tab of terminal block cover into slot of dryer rear  
panel. Secure cover with hold-down screw. now, go to  
Venting Requirements.  
A
Remove center, silver-colored terminal block screw (B).  
Remove neutral ground wire (E) from external ground  
conductor screw (A).  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
VEnTInG  
Exhaust hoods:  
Venting Requirements  
Must be at least 12" (305 mm) from ground or any object that  
may obstruct exhaust (such as flowers, rocks, bushes, or  
snow).  
WARNING  
B
4"  
C
(102 mm)  
A
4"  
Fire Hazard  
2½"  
(64 mm)  
(102 mm)  
use a heavy metal vent.  
4"  
(102 mm)  
Do not use a plastic vent.  
Recommended styles:  
A. Louvered hood  
B. Box hood  
Acceptable styles:  
C. Angled hood  
Do not use a metal foil vent.  
Failure to follow these instructions can result in death  
or fire.  
Elbows:  
45° elbows provide better airflow than 90° elbows.  
WARnInG: To reduce the risk of fire, this dryer MUST BE  
EXHAUSTED OUTDOORS.  
ImPoRTAnT: Observe all governing codes and ordinances.  
Dryer exhaust must not be connected into any gas vent,  
chimney, wall, ceiling, attic, crawlspace, or a concealed space  
of a building. Only rigid or flexible metal vent shall be used for  
exhausting.  
Only a 4" (102 mm) heavy metal exhaust  
vent and clamps may be used.  
Do not use plastic or metal foil vent.  
Good  
Better  
Clamps:  
Use clamps to seal all joints.  
Rigid metal vent:  
Recommended for best drying performance and to avoid  
Exhaust vent must not be connected or secured with screws  
or other fastening devices that extend into interior of duct  
and catch lint. Do not use duct tape.  
crushing and kinking.  
Flexible metal vent: (Acceptable only if accessible to clean)  
Must be fully extended and supported in final dryer location.  
Remove excess to avoid sagging and kinking that may result  
in reduced airflow and poor performance.  
Do not install in enclosed walls, ceilings, or floors.  
The total length should not exceed 7 3/4 ft. (2.4 m).  
noTE: If using an existing vent system, clean lint from entire  
length of the system and make sure exhaust hood is not plugged  
with lint. Replace plastic or metal foil vents with rigid metal or  
flexible metal vents. Review Vent system chart and if necessary,  
modify existing vent system to achieve best drying performance.  
Improper venting can cause moisture and lint to collect  
indoors, which may result in:  
Moisture damage to woodwork, furniture, paint, wallpaper,  
carpets, etc.  
Housecleaning problems and health problems.  
See “Venting Kits” for more information.  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Alternate installations for close clearances  
Plan Vent System  
Venting systems come in many varieties. Select the type best  
for your installation. Two close-clearance installations are shown.  
Refer to the manufacturer’s instructions.  
Recommended exhaust installations  
Typical installations vent the dryer from the rear of the dryer.  
Other installations are possible.  
B
C
D
E
A
F
G
Over-The-Top installation (also available with one offset elbow)  
B
H
I
A. Dryer  
F. Rigid metal or flexible metal vent  
G. Vent length necessary to connect elbows  
H. Exhaust outlet  
B. Elbow  
C. Wall  
D. Exhaust hood  
E. Clamps  
I. Optional side exhaust outlet  
optional exhaust installations:  
Exhaust can be converted out the right side, left side, or through  
the bottom (4-way vent kit). Each kit includes step-by-step  
instructions. For ordering information, see “Venting Kits”.  
Periscope installation  
noTE: The following kits for close clearance alternate  
installations are available for purchase.  
Venting Kits  
For more information, call 1-800-901-2042, or visit us at  
www.applianceaccessories.com. In Canada, call  
1-800-807-6777 or visit us at www.whirlpoolparts.ca.  
Part number Descriptions  
8171587RP  
4396037RP  
4396011RP  
4396014  
0–5" Metal vent periscope  
0"-18" Metal vent periscope  
18" - 29" Metal vent periscope  
29" - 50" Metal vent periscope  
In-Wall metal DuraVent™ Periscope  
4-way vent kit - white  
4392892  
279818  
W10186596  
4396028  
4-way vent kit - universal grey  
Sure Connect™ venting kit  
(over-the-top installation)  
4396009RP  
4396010RP  
4396013RB  
4396033RP  
4396727RP  
4396004  
5' Universal connect vent, flexible dryer venting  
6' SecureConnect™ vent, flexible dryer venting  
Dryer vent installer’s kit  
5' flexible dryer venting with clamps  
8' flexible dryer venting with clamps  
Dryer offset elbow  
A
B
C
4396005  
Wall offset elbow  
A. Standard rear offset exhaust installation  
B. Left or right side exhaust installation  
C. Bottom exhaust installation  
4396006RW  
4396007RW  
4396008RP  
8212662  
DuraSafe™ close elbow  
Through-the-wall vent cap  
4" steel dryer venting clamps - 2 pack  
Flush mounting louvered vent hood 4"  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Special provisions for mobile home installations:  
Install Vent System  
The exhaust vent must be securely fastened to a noncombustible  
portion of the mobile home structure and must not terminate  
beneath the mobile home. Terminate the exhaust vent outside.  
1. Install exhaust hood  
12" min.  
(305 mm)  
12" min.  
(305 mm)  
Install exhaust hood and use caulking compound to seal  
exterior wall opening around exhaust hood.  
Determine vent path:  
2. Connect vent to exhaust hood  
Select route that will provide straightest and most direct  
path outdoors.  
Plan installation to use fewest number of elbows and turns.  
When using elbows or making turns, allow as much room  
as possible.  
Bend vent gradually to avoid kinking.  
Use as few 90° turns as possible.  
Determine vent length and elbows needed for best  
drying performance:  
Use following Vent system chart to determine type of vent  
material and hood combinations acceptable to use.  
Vent must fit over the exhaust hood. Secure vent to exhaust  
hood with 4" (102 mm) clamp. Run vent to dryer location  
using straightest path possible. Avoid 90° turns. Use clamps  
to seal all joints. Do not use duct tape, screws, or other  
fastening devices that extend into interior of vent to secure  
vent, because they can catch lint.  
noTE: Do not use vent runs longer than those specified  
in Vent system chart. Exhaust systems longer than those  
specified will:  
Shorten life of dryer.  
Reduce performance, resulting in longer drying times  
and increased energy usage.  
Connect Vent  
The Vent system chart provides venting requirements that will  
help achieve best drying performance.  
1. Connect vent to exhaust outlet  
Vent System Chart  
Type  
of vent  
Box/louvered  
number of  
90° turns  
or elbows  
Angled  
hoods  
hoods  
0
1
Rigid metal  
58 ft. (17.7 m)  
48 ft. (14.6 m)  
64 ft. (20 m)  
Rigid metal  
54 ft. (16.5 m)  
2
3
4
Rigid metal 44 ft. (13.4 m)  
38 ft. (11.6 m)  
Rigid metal  
35 ft. (10.7 m) 29 ft. (8.8 m)  
Using a 4" (102 mm) clamp, connect vent to exhaust outlet  
in dryer. If connecting to existing vent, make sure vent is  
clean. Dryer vent must fit over dryer exhaust outlet and inside  
exhaust hood. Check that vent is secured to exhaust hood  
with a 4" (102 mm) clamp.  
27 ft. (8.2 m)  
21 ft. (6.4 m)  
Rigid metal  
noTE: Side and bottom exhaust installations have a 90º turn  
inside the dryer. To determine maximum exhaust length, add  
one 90º turn to the chart.  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2. move dryer to nal location  
Tighten and adjust leveling legs  
2.  
If dryer is not level, prop up using a wood block, use wrench  
to adjust legs up or down, and check again for levelness.  
Once legs are level, make sure all four legs are snug against  
the ground before tightening them.  
Move dryer to final location. Avoid crushing or kinking vent.  
After dryer is in place, remove corner posts and cardboard  
from under the dryer.  
Complete Installation Checklist  
Check that all parts are now installed. If there is an extra  
q
part, go back through steps to see what was skipped.  
level Dryer  
Check that you have all of your tools.  
q
Dispose of/recycle all packaging materials.  
q
q
1.  
level Dryer  
Check dryer’s final location. Be sure vent is not crushed  
or kinked.  
Check that dryer is level. See “Level Dryer”.  
q
Remove film on console and any tape remaining on dryer.  
q
Wipe dryer drum interior thoroughly with a damp cloth to  
remove any dust.  
q
Read “Dryer Use” in your Use and Care Guide.  
q
Set the dryer on a full heat cycle (not an air cycle) for  
20 minutes and start the dryer.  
q
If the dryer will not start, check the following:  
Controls are set in a running or “On” position.  
Start button has been pushed firmly.  
Dryer is plugged into an outlet and/or electrical supply  
is on.  
Check levelness of dryer from side to side. Repeat from  
front to back.  
Household fuse is intact and tight, or circuit breaker has  
not tripped.  
noTE: The dryer must be level for the moisture sensing system  
to operate correctly.  
Dryer door is closed.  
When the dryer has been running for 5 minutes, open the  
dryer door and feel for heat. If you feel heat, cancel cycle and  
close the door.  
q
If you do not feel heat, turn off dryer, and check the  
following:  
There may be 2 household fuses or circuit breakers for  
the dryer. Check that both fuses are intact and tight, or  
that both circuit breakers have not tripped. If there is still  
no heat, contact a qualified technician.  
Not Level  
lEVEl  
Not Level  
noTE: You may notice an odor when the dryer is first heated.  
This odor is common when the heating element is first used.  
The odor will go away.  
16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Reverse Door Swing (optional)  
4. Remove screws from hinges  
1. Place towel on dryer  
Remove screws attaching hinges to door.  
Place towel on top of dryer to avoid damaging the surface.  
5. Remove screws from door  
2.  
Remove bottom screws  
Remove screws at top, bottom, and side of door  
(5 screws). Keep door screws separate from hinge screws  
as they are different sizes. Holding door over towel on  
dryer, grasp sides of outer door and lift to separate it from  
inner door.  
noTE: Do not pry apart with putty knife or screwdriver.  
Do not pull on door seal or plastic door catches.  
Open dryer door. Remove bottom screws from dryer cabinet  
side of hinges. Loosen (do not remove) top screws from dryer  
cabinet side of hinges.  
6. Rotate outer door  
3.  
lift door off top screws  
Take outer door and rotate it 180º and set it back down on  
inner door. Be certain to keep cardboard spacer centered  
between doors. Reattach outer door panel to inner door  
panel so handle is on the side where hinges were just  
removed. Insert 5 door screws.  
Lift door until top screws in dryer cabinet are in large part of  
hinge slot. Pull door forward off screws. Set door (handle side  
up) on top of dryer. Remove top screws from dryer cabinet.  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
7. Flip door over  
9. Remove and transfer plugs  
Flip door over so handle side is down.  
Remove the 4 screws that attach 2 plugs on the left side.  
Transfer plugs to opposite side using the same 4 screws.  
8. Attach door hinges  
10.Insert screws in hinge holes on  
dryer cabinet  
noTE: 2 people maybe needed to reinstall door.  
Insert screws into the bottom holes on left side of dryer  
cabinet. Tighten screws halfway. Position door so large end of  
door hinge slot is over screws. Slide door up so screws are in  
bottom of slots. Tighten screws. Insert and tighten top screws  
in hinges.  
11.Check door strike alignment  
Reattach door hinges to dryer door so that the larger hole is  
at the bottom of the hinge.  
Close door and check that door strike aligns with door  
catch. If it is needed, slide door catch left or right  
within slot to adjust alignment.  
Troubleshooting  
See the Use and Care Guide or visit our website and  
reference Frequently Asked Questions to possibly avoid the  
cost of a service call.  
18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
notes  
19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
W10096988A  
W10306460A-SP  
©2010 Whirlpool Corporation.  
® Registered Trademark/TM Trademark of Whirlpool, U.S.A.  
2/10  
Printed in U.S.A.  
All rights reserved  
Download from Www.Somanuals.com. All Manuals Search And Download.  

KWC Indoor Furnishings K28H51000099 User Manual
La Crosse Technology Watch WWVB User Manual
LG Electronics Stereo System LFA840 User Manual
Lincoln Electric Welder SVM128 A User Manual
Link electronic Switch IEC 754 User Manual
Magellan GPS Receiver 2035 User Manual
Martin Audio Portable Speaker F15+ User Manual
Mattel Handheld Game System 8290 0920 User Manual
Microsoft Switch ES4612 User Manual
Middleby Marshall Oven PS310 User Manual