Maretron Network Card ALM100 User Manual

®
ALM100  
Alarm Module  
User’s Manual  
Revision 1.0  
Copyright © 2008 Maretron, LLP All Rights Reserved  
Maretron, LLP  
9014 N. 23rd Ave #10  
Phoenix, AZ 85021-7850  
Maretron Manual Part #: M001901  
Revision 1.0  
Page i  
Download from Www.Somanuals.com. All Manuals Search And Download.  
®
Table of Contents  
2.4.1 NMEA 2000® Connection............................................................................... 4  
2.5.4.1 NMEA 2000® PGN Enable/Disable .................................................. 6  
Table of Figures  
Figure 3 – NMEA 2000® Connector Face Views ....................................................................... 5  
Revision 1.0  
Page iii  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
®
1 Introduction  
Congratulations on your purchase of the Maretron Alarm Module. Maretron has designed and  
built your ALM100 to the highest standards for years of dependable and accurate service.  
Maretron’s Alarm Module generates visual and audible alerts for any monitored condition. The  
Alarm Module includes an extremely loud 105 dB SPL Piezoelectric sounder, along with a red  
high-brightness LED to indicate an alarm condition. A second green LED indicates that the  
Alarm Module is powered and ready to be triggered. The audible alarm can sound any one of  
32 distinct pre-programmed patterns to indicate different alerts. The Alarm Module can be  
triggered by alarms generated by Maretron’s N2KView Vessel Monitoring System, or by  
Maretron’s DSM250 Color Graphics Display. The Alarm Module mounts in a standard electric  
box or can be flush mounted on any surface. Completely waterproof, the Alarm Module can be  
mounted inside or outside the vessel.  
The Maretron ALM100 is designed to operate within the harsh demands of the marine  
environment. However, no piece of marine electronic equipment can function properly unless  
installed, configured, and maintained in the correct manner. Please read carefully and follow  
these instructions for installation, configuration, and usage of the Maretron ALM100 in order to  
ensure optimal performance.  
1.1 Firmware Revision  
This manual corresponds to ALM100 firmware revision 1.0.2.  
1.2 ALM100 Features  
The Maretron ALM100 has the following features.  
NMEA 2000 Network Interface  
Super loud 105dB audible alarm  
Bright Red LED visual alarm  
Green LED status indicator  
Mounts in standard electrical wall box or flush mount box  
Multiple user-selectable alarm patterns  
o “Code-3” (ISO 8201, Smoke/Fire) 0.5s on, 0.5s off, 0.5s on, 0.5s off, 0.5s on,  
1.5s off  
o “Temporal 4” (T4, CO) 0.1s on, 0.1s off, 0.1s on, 0.1s off, 0.1s on, 0.1s off, 0.1s  
on, 5.0s off  
o “IMO Code 1a (7 pulse)” (General Emergency Alarm, SOLAS III/50,III/6.4) [1 s  
on, 1 s off][repeat 7 times]long tone (7s on), 1 s off  
o “IMO Code 2” Continuous on  
o “IMO Code 3.a” [0.5 s on, 0.5 s off][repeat continually]  
Waterproof - Can be mounted indoors or outdoors  
Revision 1.0  
Page 1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
ALM100 User's Manual  
1.3 ALM100 Accessories  
Maretron offers the following accessories for the ALM100:  
CP-WH-ALM100  
ALM100 White Faceplate  
1.4 Quick Install  
Installing the Maretron ALM100 involves the following five steps. Please refer to the individual  
sections for additional details.  
1. Unpack the box (Section 2.1)  
2. Choose a mounting location (Section 2.2)  
3. Mount the ALM100 (Section 2.3)  
4. Connect the ALM100 (Section 2.4)  
5. Configure the ALM100 (Section 2.5)  
2 Installation  
2.1 Unpacking the Box  
When unpacking the box containing the Maretron ALM100, you should find the following items:  
1 – ALM100 Alarm Module  
1 – ALM100 Black Faceplate  
2 – ALM100 Mounting Screws  
2 – Faceplate Mounting Screws  
1 – Faceplate Gasket  
1 – Sounder Volume Control Baffle Plate  
1 – Sounder Volume Control Shutter  
1 – Screw for Sounder Volume Control  
1 – Sounder Collar  
1 – Sounder Gasket  
1 – ALM100 User’s Manual  
1 – Warranty Registration Card  
If any of these items are missing or damaged, please contact Maretron.  
2.2 Choosing a Mounting Location  
Please consider the following when choosing a mounting location.  
1. The ALM100 is waterproof, so it can be mounted in a damp or dry location.  
2. The orientation is not important, so the ALM100 can be mounted on a horizontal deck,  
vertical bulkhead, or upside down if desired.  
3. The ALM100 is temperature-rated to 55°C (130°F), so it should be mounted away from  
engines or engine rooms where the operating temperature exceeds the specified limit.  
Page A2  
Appendix A – NMEA 2000 Interfacing  
Revision 1.0  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
®
2.3 Mounting the ALM100  
The ALM100 is designed to be mounted in an ANSI/NEMA WD 6 electrical switch box, but it  
may also be mounted directly into a wall.  
If mounting the ALM100 into an electrical box, which can in turn be surface-mounted onto a  
wall or bulkhead, attach the ALM100 securely to the electrical box using the included mounting  
screws or other fasteners as shown in Figure 1 below.  
ALM100 Faceplate  
Faceplate Gasket  
NMEA 2000 Cable (not  
included)  
ALM100 Mounting Screws (x2)  
Faceplate  
Mounting Screws  
(x2)  
Sounder Gasket  
Electrical Box (not  
included)  
Volume Control Baffle Plate  
Sounder Collar  
ALM100 Alarm Module  
Volume Control Shutter  
Volume Control Screw  
Figure 1 – Mounting the ALM100 into an Electrical Box  
If flush mounting the ALM100 into a wall, use the installation template in Section 7 as a guide  
to cut the hole in the wall and drill the mounting holes for the ALM100. Next, attach the  
ALM100 securely to the wall using the included mounting screws or other fasteners as shown  
Revision 1.0  
Page 3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
ALM100 User's Manual  
ALM100 Faceplate  
Faceplate Gasket  
NMEA 2000 Cable (not  
included)  
ALM100 Mounting Screws (x2)  
Faceplate  
Mounting Screws  
(x2)  
Sounder Gasket  
Volume Control Baffle Plate  
Sounder Collar  
ALM100 Alarm Module  
Volume Control Shutter  
Volume Control Screw  
Figure 2 – Flush Mounting the ALM100 Directly to a Wall  
The following instructions apply wither mounting the ALM100 into an electrical box or to a wall:  
1) Connect the NMEA 2000 cable to the connector on the ALM100 Alarm Module  
2) Using the included ALM100 mounting screws, mount the ALM100 Alarm Module to the  
wall or electrical box  
3) Place the sounder gasket over the sounder on the ALM100 alarm module  
4) Place the faceplate gasket over the ALM100 alarm module  
5) Mount the ALM100 faceplate over the ALM100 alarm module using the included  
faceplate mounting screws.  
6) Screw the sounder collar onto the sounder of the ALM100 alarm module, which should  
now be protruding through the large hole in the faceplate, and tighten until snug.  
7) Optionally, you may install the volume control by first placing the volume control baffle  
plate over the front of the sounder, then placing the volume control shutter over the  
volume control baffle plate, and finally attaching both to the sounder by threading the  
volume control screw into the hole in the center of the sounder.  
2.4 Connecting the ALM100  
The ALM100 requires a single type of electrical connection: the NMEA 2000® connection (refer  
to Section 2.4.1).  
2.4.1 NMEA 2000® Connection  
The NMEA 2000® connector can be found on the rear of the enclosure. The NMEA 2000®  
connector is a round five pin male connector (see Figure 3). You connect the ALM100 to an  
Page A4  
Appendix A – NMEA 2000 Interfacing  
Revision 1.0  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
®
NMEA 2000® network using a Maretron NMEA 2000® cable (or compatible cable) by  
connecting the female end of the cable to the ALM100 (note the key on the male connector  
and keyway on the female connector). Be sure the cable is connected securely and that the  
collar on the cable connector is tightened firmly. Connect the other end of the cable (male) to  
the NMEA 2000® network in the same manner. The ALM100 is designed such that you can  
plug or unplug it from an NMEA 2000® network while the power to the network is connected or  
disconnected. Please follow recommended practices for installing NMEA 2000® network  
products.  
Figure 3 – NMEA 2000® Connector Face Views  
2.4.2 Checking Connections  
Once the NMEA 2000® connection to the ALM100 has been completed, you should first check  
to see that power is being received by the ALM100 by checking that the green power LED on  
the front of the unit is illuminated. Next, you should check to see that information is being  
properly received by using the ALM100 test function on an appropriate NMEA 2000® display,  
such as the Maretron DSM250. If the alarm does not sound and flash the red LED during  
testing, please refer to Section 4, “Troubleshooting”.  
2.5 Configuring the ALM100  
The ALM100 will sound alarms received over the NMEA 2000 network as it is shipped from the  
factory; however, it may require configuration, depending on whether you have multiple  
ALM100’s installed on the network. There are several configurable items within the ALM100,  
which are detailed in the remainder of this section.  
You configure the ALM100 using a Maretron DSM250 display or other NMEA 2000® display  
unit that is capable of configuring the ALM100. Please refer to the Maretron DSM250 User’s  
Manual for details.  
Revision 1.0  
Page 5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
ALM100 User's Manual  
2.5.1 Device Instance  
NMEA 2000® provides a unique device instance for each alarm device on a vessel. This value  
should be programmed in each ALM100 so that each ALM100 is associated with a unique  
device instance number. The default instance number is 0, which is used to indicate the first  
ALM100 that is hooked to the network. Subsequent ALM100s connected to the network would  
be numbered 1, 2, and so on.  
2.5.2 Label  
The ALM100 may be programmed with a text label that will be displayed in monitoring software  
and displays that recognize device labels, such as the Maretron N2KView Vessel Monitoring  
System and the Maretron DSM250 display. The label will let you assign an easy-to-remember  
text label (example: “Alarm in Pilothouse”) to make it easy for you to identify the device as you  
are configuring the monitoring software or display, as well as when alerts are generated.  
2.5.3 Test Annunciator  
Devices capable of configuring the ALM100 also have the ability to cause the ALM100 to  
generate an alarm indication, flashing the red alarm LED and sounding the annunciator. You  
may use this function to determine whether the ALM100 is properly connected and configured.  
When you select this option, the red alarm LED and annunciator will be activated for a short  
period of time.  
2.5.4 Advanced Configuration…  
Certain parameters do not normally need to be set in order for normal operation, but are  
included in an advanced configuration section for use in special situations.  
2.5.4.1 NMEA 2000® PGN Enable/Disable  
The ALM100 is capable of transmitting NMEA 2000® messages (or PGNs) associated with  
monitored switch circuits. You may individually enable or disable each of these messages. You  
may also change the rate of transmission of each of these messages if desired.  
2.5.4.2 Restore Factory Defaults  
Selecting this configuration option causes all stored parameters in the ALM100 to be reset to  
the values they contained when the unit was manufactured.  
2.5.4.3 Installation Description…  
The ALM100, along with all other Level A certified NMEA devices, has two user-programmable  
installation description fields. You may program these fields with information specific to the  
device, such as date installed, the initials/name of the installer, the physical location of the  
device, etc. This configuration option will allow you to program the values of these fields.  
3 Maintenance  
Regular maintenance is important to ensure continued proper operation of the Maretron  
ALM100. Perform the following tasks periodically:  
Page A6  
Appendix A – NMEA 2000 Interfacing  
Revision 1.0  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
®
Clean the unit with a soft cloth. Do not use chemical cleaners as they may remove  
paint or markings or may corrode the ALM100 enclosure or seals.  
Ensure that the unit is mounted securely and cannot be moved relative to the mounting  
surface. If the unit is loose, tighten the mounting screws.  
Check the security of the cable connected to the NMEA 2000® connector, and tighten if  
necessary.  
4 Troubleshooting  
If you notice unexpected operation of the Maretron ALM100, follow the troubleshooting  
procedures in this section to remedy simple problems. If these steps do not solve your  
problem, please contact Maretron Technical Support (refer to Section 6 for contact  
information).  
Symptom  
Troubleshooting Procedure  
The ALM100 is not  
visible on the NMEA  
2000® network.  
Ensure that the ALM100 is properly connected to the NMEA 2000®  
network.  
Ensure that the segment of the NMEA 2000® network to which the  
ALM100 is connected is powered. Check that the greed power  
LED on the front of the ALM100 is illuminated.  
Ensure that the ALM100 you wish to monitor is not configured as  
“Disabled”.  
Ensure that the ALM100 has the appropriate NMEA 2000® PGNs  
enabled as described in Section 2.5.5.  
The ALM100 does not  
sound when expected.  
Ensure that the ALM100 is properly connected and powered as  
described in the preceding section. Use the “Test Annunciator”  
function of the DSM250 display to verify that the ALM100 is  
receiving messages, as described in section 2.5.3.  
Ensure that alerts are configured correctly. Ensure that the  
ALM100 has been configured with an instance number as  
described in section 2.5.1. Check the alarm configuration in  
N2KView or the DSM250 to ensure that this instance number  
appears in the list of annunciators to sound for the particular alarm.  
Please refer to the DSM250 User’s Manual or the N2KView User’s  
Manual for details on alarm configuration.  
Revision 1.0  
Page 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
ALM100 User's Manual  
5 Technical Specifications  
As Maretron is constantly improving its products, all specifications are subject to change  
without notice. Maretron products are designed to be accurate and reliable; however, they  
should be used only as aids to navigation and not as a replacement for traditional navigation  
aids and techniques.  
Specifications  
Parameter  
Value  
105 dB SPL  
2.9 kHZ  
Comment  
Mechanical Volume Control  
Annunciator Volume  
Annunciator Frequency  
Certifications  
Parameter  
Comment  
NMEA 2000® Standard  
Level A  
Maritime Navigation and Radiocommunication Equipment & Systems  
Maritime Navigation and Radiocommunication Equipment & Systems  
FCC and CE Mark  
IEC 61162-3  
IEC 60945  
Electromagnetic Compatibility  
NMEA 2000® Parameter Group Numbers (PGNs)  
Description  
Periodic Data PGNs  
PGN #  
PGN Name  
Default Rate  
1 time/second  
N/A  
128720 Proprietary Alarm Status*  
126464 PGN List (Transmit and Receive)  
126996 Product Information  
126998 Configuration Information  
059392 ISO Acknowledge  
059904 ISO Request  
Response to Requested PGNs  
N/A  
N/A  
N/A  
N/A  
Protocol PGNs  
060928 ISO Address Claim  
065240 ISO Address Command  
126208 NMEA  
N/A  
N/A  
N/A  
Maretron Proprietary PGNs  
128720 Configuration  
N/A  
*Future firmware updates will allow the ALM100 to be in conformance with the upcoming  
NMEA 2000 alarm messaging protocol, once it is defined.  
Electrical  
Parameter  
Value  
9 to 32 Volts  
100 mA  
2
Comment  
Operating Voltage  
Power Consumption  
Load Equivalence Number (LEN)  
Reverse Battery Protection  
Load Dump Protection  
DC Voltage  
NMEA 2000 Interface  
NMEA 2000® Spec. (1LEN = 50 mA)  
Indefinitely  
Yes  
Yes  
Energy Rated per SAE J1113  
Mechanical  
Parameter  
Size  
Value  
2.75” x 4.50” x 2.00”  
Comment  
Including wall plate – Mounts in standard  
(70mm x 114mm x 51mm) single-gang electrical box  
Weight  
13 oz. (368.5g)  
Page A8  
Appendix A – NMEA 2000 Interfacing  
Revision 1.0  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
®
6 Technical Support  
If you require technical support for Maretron products, you can reach us in any of the following  
ways:  
Telephone: 1-866-550-9100  
Fax: 1-602-861-1777  
Mail: Maretron, LLC  
Attn: Technical Support  
9014 N. 23rd Ave Suite 10  
Phoenix, AZ 85021 USA  
Revision 1.0  
Page 9  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
ALM100 User's Manual  
7 Installation Template  
Please check the dimensions before using the following diagram as a template for drilling the  
mounting holes because the printing process may have distorted the dimensions.  
Figure 4 – Mounting Surface Template  
Page A10  
Appendix A – NMEA 2000 Interfacing  
Revision 1.0  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
®
8 Maretron (2 Year) Limited Warranty  
Maretron warrants the ALM100 to be free from defects in materials and workmanship for two (2) years from the  
date of original purchase. If within the applicable period any such products shall be proved to Maretron’s  
satisfaction to fail to meet the above limited warranty, such products shall be repaired or replaced at Maretron’s  
option. Purchaser's exclusive remedy and Maretron’s sole obligation hereunder, provided product is returned  
pursuant to the return requirements below, shall be limited to the repair or replacement, at Maretron’s option, of  
any product not meeting the above limited warranty and which is returned to Maretron; or if Maretron is unable to  
deliver a replacement that is free from defects in materials or workmanship, Purchaser’s payment for such  
product will be refunded. Maretron assumes no liability whatsoever for expenses of removing any defective  
product or part or for installing the repaired product or part or a replacement therefore or for any loss or damage  
to equipment in connection with which Maretron’s products or parts shall be used. With respect to products not  
manufactured by Maretron, Maretron’s warranty obligation shall in all respects conform to and be limited to the  
warranty actually extended to Maretron by its supplier. The foregoing warranties shall not apply with respect to  
products subjected to negligence, misuse, misapplication, accident, damages by circumstances beyond  
Maretron’s control, to improper installation, operation, maintenance, or storage, or to other than normal use or  
service.  
THE FOREGOING WARRANTIES ARE EXPRESSLY IN LIEU OF AND EXCLUDES ALL OTHER EXPRESS OR  
IMPLIED WARRANTIES, INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF  
MERCHANTABILITY AND OF FITNESS FOR A PARTICULAR PURPOSE.  
Statements made by any person, including representatives of Maretron, which are inconsistent or in conflict with  
the terms of this Limited Warranty, shall not be binding upon Maretron unless reduced to writing and approved by  
an officer of Maretron.  
IN NO CASE WILL MARETRON BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES, DAMAGES  
FOR LOSS OF USE, LOSS OF ANTICIPATED PROFITS OR SAVINGS, OR ANY OTHER LOSS INCURRED  
BECAUSE OF INTERRUPTION OF SERVICE. IN NO EVENT SHALL MARETRON’S AGGREGATE LIABILITY  
EXCEED THE PURCHASE PRICE OF THE PRODUCT(S) INVOLVED. MARETRON SHALL NOT BE SUBJECT  
TO ANY OTHER OBLIGATIONS OR LIABILITIES, WHETHER ARISING OUT OF BREACH OF CONTRACT OR  
WARRANTY, TORT (INCLUDING NEGLIGENCE), OR OTHER THEORIES OF LAW WITH RESPECT TO  
PRODUCTS SOLD OR SERVICES RENDERED BY MARETRON, OR ANY UNDERTAKINGS, ACTS OR  
OMISSIONS RELATING THERETO.  
Maretron does not warrant that the functions contained in any software programs or products will meet  
purchaser’s requirements or that the operation of the software programs or products will be uninterrupted or error  
free. Purchaser assumes responsibility for the selection of the software programs or products to achieve the  
intended results, and for the installation, use and results obtained from said programs or products. No  
specifications, samples, descriptions, or illustrations provided Maretron to Purchaser, whether directly, in trade  
literature, brochures or other documentation shall be construed as warranties of any kind, and any failure to conform  
with such specifications, samples, descriptions, or illustrations shall not constitute any breach of Maretron’s limited  
warranty.  
Warranty Return Procedure:  
To apply for warranty claims, contact Maretron or one of its dealers to describe the problem and determine the  
appropriate course of action. If a return is necessary, place the product in its original packaging together with  
proof of purchase and send to an Authorized Maretron Service Location. You are responsible for all shipping and  
insurance charges. Maretron will return the replaced or repaired product with all shipping and handling prepaid  
except for requests requiring expedited shipping (i.e. overnight shipments). Failure to follow this warranty return  
procedure could result in the product’s warranty becoming null and void.  
Maretron reserves the right to modify or replace, at its sole discretion, without prior notification, the warranty listed  
above. To obtain a copy of the then current warranty policy, please go to the following web page:  
Revision 1.0  
Page 11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 

LaCie Computer Drive LaCinema Rugged HD User Manual
La Crosse Technology Portable Radio TX31U IT User Manual
Liebert Power Supply 1000 3000VA 60 Hz 120V User Manual
Lincoln Electric Welder SVM118 A User Manual
Magnasonic CD Player MCD306 User Manual
Makita Saw 4305T User Manual
Marantz CD Player DR6050 User Manual
MB QUART Car Amplifier RAB 1450 User Manual
McCall Refrigeration Refrigerator MCCF27 User Manual
Metra Electronics Automobile Accessories 99 4700 User Manual