ECHNICAL INFORMATION
PRODUCT
T
P 1/ 5
Models No.
Description
BUB360
Cordless Blower 36V
L2
H
CONCEPT AND MAIN APPLICATIONS
Model BUB360 is a cordless blower powered by 36V/ 2.6Ah
Li-ion battery BL3626. This model will be one of the best choice
for use especially in public spaces or among residential areas
instead of gas-powered blowers.
L1
W
Features High/ Low push button for two different air volume settings.
This product is available with the following model number
and specifications.
Model No. Charger Battery Battery cover
Dimensions: mm (")
BUB360Z
No
No
No
Length (L1)
Length (L2)
921 (36-1/4)
436 (17-1/8)
The model also includes the accessory listed below
in "Standard equipment".
Width (W)
Height (H)
142 (5-5/8)
204 (8)
*L1: Length with Long nozzle
*L2: Length with without Long nozzle
Specification
Model No.
BUB360
36
Voltage: V
Capacity: Ah
Battery
2.6
Cell
Li-ion
22 with DC36RA
17,000
Charging time (approx.): min.
High
No load speed: min-1 = rpm
Low
10,000
High
Low
High
Low
Max air volume*1:
m3/sec (m3/min.) [ft3/min.]
0.073 (4.4) [160]
0.043 (2.6) [92]
93
57
Max air velocity*2: m/sec
Air volume setting function
Yes (2 settings: High/ Low)
High
Low
14
30
No
No
Continuous run time (approx.)
on a single full battery*1: min.
Vacuum function
Variable speed control by trigger
Weight according to
EPTA-Procedure 01/2003*4: kg (lbs)
3.1 (6.8)
*1 without Long nozzle
*2 with Long nozzle
*3 with Battery BL3626
*4 with Battery BL3626 and Long nozzle
Standard equipment
Long nozzle .................. 1
Shoulder strap ............. 1
Note: The standard equipment for the tool shown above may differ by country.
Optional accessories
Battery BL3626, Charger DC36RA, Battery adapter BAN36N
Download from Www.Somanuals.com. All Manuals Search And Download.
P 2/ 5
Repair
CAUTION: Repair the machine in accordance with “Instruction manual” or “Safety instructions”.
[1] NECESSARY REPAIRING TOOLS
Description
Use for
Socket bit 8-55 (width across flats: 8mm) Disassembling/ Assembling M5-8 Hex nut for Fan 95
[2] DISASSEMBLY/ASSEMBLY
[2]-1. Fan, Armature
DISASSEMBLING
(1) Remove Carbon Brush as illustrated in Fig. 1.
Fig. 1
Remove two Holder cap covers by
levering up with Slotted screwdriver.
Remove two Brush holder caps and Carbon brushes.
Carbon brush
Holder cap cover
(2pcs.)
Brush holder cap (2pcs.)
(2) Separate Housing set (R) and take out Motor section as illustrated in Fig. 2.
Fig. 2
Remove 13pcs. of 4x18 Tapping screws.
And separate Housing set (R) from Housing
set (L).
Separate Motor section (Endbell complete, Armature,
Yoke unit, Fan 95) from Housing set (L).
Note: Do not lose Hanger
Housing set (R)
Housing set (R)
Hanger
Housing set (L)
Motor section
(3) Fan 95 and Armature can be replaced as illustrated in Fig. 3.
Fig. 3
1. Separate Motor section
from Endbell complete.
2. Hold Fan 95 by hand and turn M5-8 Hex nut for Fan 95
clockwise using cordless impactdriver with Socket bit 8-55.
Note: M5-8 Hex nut has a left handed thread.
Yoke unit
Socket bit 8-55 Cordless impactdriver
Fan 95
Armature
Endbell
complete
Flat washer 8
M5-8 Hex nut
Fan 95
Fan 95
Flat washer 5
Download from Www.Somanuals.com. All Manuals Search And Download.
P 3/ 5
Repair
[2] DISASSEMBLY/ASSEMBLY
[2]-1. Fan, Armature (cont.)
ASSEMBLING
Take the disassembling step in reverse.
Note: 1) Do not forget to set Flat washer 5 and Flat washer 8 in place. (Fig. 3)
2) Fit two notches of Yoke unit to two protrusions on Housing set (L). (Fig. 4)
3) Before assembling Housing set (R), mount Hanger on Housing set (L) and (R). (Fig. 2)
Fig. 4
Fan 95
two protrusions of Housing set (L)
two notches
of Yoke unit
[2]-2. Switch unit
DISASSEMBLING
(1) Remove Housing set (R) from Housing set (L). (Figs. 1 and 2)
It is not necessary to remove Motor section.
(2) Remove Switch unit by disconnect Connectores as illustrated in Fig. 5.
Fig. 5
Switch unit
Housing set (L)
Connector of Switch unit
Connector of Controller
Controller
ASSEMBLING
Take the disassembling step in reverse.
Download from Www.Somanuals.com. All Manuals Search And Download.
P 4/ 5
Circuit diagram
Fig. D-1
Color index of lead wires' sheath
Black
Red
White
Blue
Yellow
Connect Line filters as illustrated below if they are used.
Housing set (L) side
Terminal
Line filter
Endbell
complete
Line filter
Controller
Line filter
Switch
unit
Housing set (R) side
Download from Www.Somanuals.com. All Manuals Search And Download.
P 5/ 5
Wiring diagram in Housing set (L)
Fig. D-2
Line Filter
Pass Line filter’s Lead wires (black, red)
through Line filter, and then put the Line
filter as illustrated below.
Endbell Complete
Put Connectors to the position
Fix the following Lead wires with
these Lead wire holders.
* Endbell’s Lead wires (black, red)
* Controller’s Lad wires (black, red)
Guide Switch units’s Lead
illustrated below, and fix
the Lead wires of Switch unit
and Controller with Lead wire
holders.
wires between Ribs
carefully not to put them
on the Ribs.
Line filter
Put Insulated
connectors here.
Rib
Connector
Line filter
Rib
Do not pass Controller’s
lead wire (yellow) between
Rib and Terminal.
Terminal
Endbell
complete
Yoke unit
Wire connecting portion
Fan 95
Controller
Flag connector
Passing Controller’s Lead wires (black, red) through Line filter,
coil them one time to Line filter as illustrated below.
Terminal
Line filter
Line filter
to
Terminal
Lead Wire Holder
Motor section side
Fix the Lead wires with Lead wire holder.
The Flag connector has to be
connected so that its wire
connecting portion faces
In case of the specifications without Line filter,
no need to fix the lead wires with Lead wire holder.
Motor section side (front side).
Download from Www.Somanuals.com. All Manuals Search And Download.
|