INSTALLATION
INSTALLATION INSTRUCTIONS FOR
W A R N I N G
• This Thermostat is a line voltage (120 / 240 Vac) control. Do not
install it unless you are completely familiar with house wiring. If
improperly handled, there can be a risk of electric shock hazard
which may cause serious injury or death.
• The thermostat is rated for normal full load current on a dual
residential 20A circuit breaker or fuse block. Do not use on circuits
protected by higher-rated over-current protection devices. Some
sustained fault conditions can cause product failure.
ELV1/PSPLV510
Programmable Line Voltage Thermostat
LUX PRODUCTS CORPORATION • Mt. Laurel, New Jersey 08054, USA
43331-04
• Do NOT connect to voltage different from the device rating.
WARNING: Use Energizer® or DURACELL® Alkaline Batteries Only.
Energizer® is a registered trademark of Eveready Battery Company, Inc.
DURACELL® is a registered trademark of The Gillette Company, Inc.
C A U T I O N
• Disconnect power supply before making wire connections to
prevent electrical shock or equipment damage.
• All wiring must comply with applicable codes and ordinances.
• Thermostats are designed to be used with appliances having a limit
control.
• Maximum load for this thermostat MUST NOT EXCEED 3800W,
otherwise a potential fire hazard exists.
Location:
Install a vertical switch box for mounting the thermostat
approximately 1.5 m (5 ft.) above the floor on an inside wall where the
thermostat will be exposed to average room temperature. The
thermostat must be placed away from concealed warm or cold water
pipes, air ducts, or drafts from hallways, fireplaces or stairways to
sense temperature properly. Do not place the thermostat above the
heater.
WIRING
1. Disconnect power while installing. Double check that the
thermostat is rated for the voltage and amperage load to be
controlled.
2. Remove the cover by carefully pressing the button at the bottom of
the thermostat and swinging the body up and away.
3. When replacing an old line voltage wall thermostat, remove it
carefully to avoid damage to the insulation on the wiring. Check the
old insulation for cracks, nicks, or fraying and apply certified
electrical tape where necessary to achieve adequate insulation, or
replace the wires in an approved fashion.
4. Attach the wires with solderless wire connectors (provided). Be
sure that all wire connectors are tight.
For Use On:
Batteries
• Heating Only 120/240 Vac Single
Pole Applications
• Two Energizer® or DURACELL®
“AA” alkaline batteries
(not included)
• Baseboard, Ceiling Cable and
other Radiant Heat
Programming
• Preprogrammed - 4 Periods per
day
• 5 / 2 Programming
• Weekdays/Weekends can be
different
• °F / °C Changeable
• Temporary Temperature Override
• Vacation Hold
Not For Use On:
• Double Pole Applications
• Heating/Cooling or Cooling Only
• Low Voltage (24Vac) Systems
Electrical Rating
16A at 120/240 Vac
1900W at 120Vac
(Non-Inductive)
3800W at 240 Vac
(Non-Inductive)
Dimensions
• 4.7” T x 2.7” W x 2.4” D
• 1.4” D from wall surface
Temperature Differential
Wall Plate
• 4.8” W x 5.0” H Wallplate
Included
•
1°F Factory Preset; Adjustable
© COPYRIGHT 2004 LUX PRODUCTS CORPORATION. ALL RIGHTS RESERVED
1
Download from Www.Somanuals.com. All Manuals Search And Download.
Setting the TIME and DAY
P R O G R A M M I N G
C H A R T
C
A
U
T
I
O
N
DAY
PERIOD
TIME
TEMP
M
O
The thermostat is protected against normal static electric
discharges. However, in extremely dry weather you should
touch another metal object before the thermostat to avoid
potential loss of programs.
MORN
DAY
MORN
DAY
EVE
MONDAY
through
FRIDAY
NIGHT
AM
EVE
NIGHT
MORN
DAY
Open the drop down door on the front of the thermostat. Rotate
SATURDAY
and
SUNDAY
the dial to the SET DAY/TIME position. You should see the display
pictured above with a flag pointing to a day of the week flashing. When
you are finished setting the day and time, rotate the dial to RUN
to return to normal operation or to another position to continue
programming.
EVE
NIGHT
TECHNICAL SERVICE
UP
To change
current day.
To set current time. The
time (e.g."12:00 AM")
will be flashing.
UP
NEXT
To change the
current time.
If you have problems installing this thermostat, please reread the
instructions carefully. Be sure the batteries are good, and installed
correctly. Press the RESET button if erratic operation is encountered.
If you still have problems, call Technical Service at 1-856-234-8803
between 8:00 a.m. and 4:30 p.m. Eastern Standard Time, Monday
through Friday or visit our online technical support at
DOWN
TEMPERATURE OVERRIDE AND TEMPERATURE HOLD
These features let you change the current Set Temperature without
changing the programs stored in your thermostat’s memory.
Temporary Temperature Override
WARRANTY
• Press UP/DOWN to change the current
temperature setting. The OVERRIDE indicator
Limited Warranty: If this unit fails because of defects in materials
or workmanship within one year of date of original purchase, LUX will,
at its option, repair or replace it. This warranty does not cover damage
by accident, misuse, or failure to follow installation instructions.
Implied warranties are limited in duration to one year from date of
original purchase. Some states do not allow limitations on how long an
implied warranty lasts, so the above limitation may not apply to you.
Please return malfunctioning or defective units to the participating
retailer from which purchase was made, along with proof of purchase.
Please refer to Technical Service Section before returning thermostat.
Purchaser assumes all risks and liability for incidental and
consequential damage resulting from installation and use of this unit.
Some states do not allow the exclusion of incidental or consequential
damages, so the above exclusion may not apply to you. This warranty
gives you specific legal rights and you may also have other rights
which vary from state to state. Applicable in the U.S.A. only.
UP
M
O
appears on display.
MORN
DAY
H
E
A
T
EVE
• The Override feature will be automatically
canceled at the start of the next program period.
PM
NIGHT
DOWN
E
OVERRID
• To cancel OVERRIDE prior to next program
period press UP/DOWN until original set
temperature appears. OVERRIDE indicator will
d
i
s
a
p
p
e
a
r
from display.
VACATION Temperature HOLD
• Press HOLD. Adjust temperature as
desired with UP/DOWN.
HOLD
M
O
MORN
DAY
H
E
A
T
• Temperature setting will not change even
EVE
PM
NIGHT
after next program period begins.
HOLD
• To clear, press HOLD again.
ADVANCED FEATURES
TEMPERATURE SWING
A thermostat works by turning your heating on and off whenever
the room temperature varies a certain number of degrees from the
set-point temperature. This variation is the “swing.”
Your system should cycle on about 3 to 6 times per hour. A
smaller swing number increases the number of cycles, so room
temperature is more constant. A larger swing number decreases the
number of cycles, to save energy in most cases.
HOLD
NEXT
Press together
SWING SETTINGS
To change
swing
Dial must be in
the run position
DOWN
UP
MORN
DAY
EVE
NEXT
Press to set.
NIGHT
CHANGING FROM °F to °C AND A 12HR CLOCK TO A 24HR CLOCK
• Warning: Making these changes will require you to reset the
thermostat. Copy any of your customized programs onto the chart
below. This will be your reference to reenter the programs
afterward.
• Located at the center of the circuit board of your thermostat are two
dip switches.
• To change to Celsius, move the top dip switch to the right.
• To change to a 24HR clock, move the bottom dip switch to the right.
• Press the reset key on the front of the thermostat for the changes to
take effect.
• Reprogram as necessary.
© COPYRIGHT 2004 LUX PRODUCTS CORPORATION. ALL RIGHTS RESERVED
Download from Www.Somanuals.com. All Manuals Search And Download.
3
|