Install guide 3M-22
Caution
• Your thermostat is a precise instrument, handle it with care.
• Turn off electricity to the appliance before installing or
servicing thermostat or any part of the system.
• Do not turn electricity back on until work is completed.
• Do not short (jumper) across electric terminals at control on
furnace or air conditioner to test the system. This will damage
the thermostat and void your warranty.
• All wiring must conform to local codes and ordinances.
• This thermostat is designed for use with 24 volt AC and
millivolt systems. The thermostat should be limited to a
maximum of 1.0 amps; higher amperage may cause damage
to the thermostat.
Download from Www.Somanuals.com. All Manuals Search And Download.
ENGLISH
Install guide 3M-22
To avoid electrical shock and to prevent damage to the furnace, air conditioner,
and thermostat, disconnect the power supply before beginning work.
This can be done at the circuit breaker, or at the appliance.
Caution
You will need a small Phillips screwdriver and possibly a drill
with 3/16-in. (4.8mm) bit for wall mounting.
Tools
Location
Replacement installations - mount the new thermostat in place of the old one.
New installations - follow the guidelines listed below.
• Locate the thermostat on an inside wall, about 5 ft. (1.5m) above the floor, and
in a room that is used often.
PG
1
• Do not install it where there are unusual heating conditions, such as: in direct
sunlight; near a lamp, radio, television, radiator register, or fireplace; near hot
water pipes in a wall; near a stove on the other side of a wall.
• Do not locate in unusual cooling conditions, such as: on a wall separating an
unheated room; or in a draft from a stairwell, door, or window.
• Do not locate in a damp area. This can
Good
lead to corrosion that will shorten thermostat
life.
• Do not locate where air circulation is poor,
such as: in a corner or an alcove; or behind
an open door.
5ft.
(1.5m)
• Do not install the unit until all construction
work and painting has been completed.
• This thermostat does not require leveling.
PG
Download from Www.Somanuals.com. All Manuals Search And2Download.
Remove old unit
IMPORTANT : LABEL ALL WIRES
BEFORE DISCONNECTING THEM!
• Switch electricity to the furnace and
air conditioner OFF; then proceed with the
following steps.
• Remove cover from old thermostat. Most are
snap-on types and simply pull off. Some have
locking screws on the side or front. These must
be loosened. Note the letters printed near the terminals. Attach
labels (enclosed) to each wire for identification.
Read instructions carefully before removing any wiring from existing thermostat.
Wires must be labeled before they are removed. THERE IS NO STANDARD
Caution
COLOR CODE. When removing wires from their terminals, ignore the color of
the wires since these may not comply with any standard.
PG
3
• Label the wires one at a time. You must label all the wires before
you proceed. With all wires labeled, remove them from the old unit.
• Make sure the wires do not fall back inside the wall. You can wind
them around a pencil to keep them from falling.
• Loosen all screws on the old thermostat and remove it from the wall.
• Fill wall opening with non-combustible insulation to prevent drafts.
Prepare wires
• You will need at least 2.6" of wire for each
of your connections to the 3M-22.
• If you do not have enough wire, splice
additional wire to allow enough slack.
2.6"
W
• Fan out wires below the hole as shown.
Trim
PG
4
Download from Www.Somanuals.com. All Manuals Search And Download.
PG
5
Before you Connect Wires
Please follow these guidelines for safe and secure
wire connections.
• Easy Terminals do not require stripping the wire.
• Clip any bare wire from previous installation.
• Take care not to damage the labels for each wire in handling.
• Fan wires out as illustrated with 3M-22 below the wall opening.
• Wires will dress behind the 3M-22 and up over the terminal area.
• Use the Step-By-Step diagram as your guide.
• Do not bunch wires behind 3M-22. Feed slack back into the wall
opening.
Do not allow wires to touch each other or parts on thermostat.
Caution
• Insert the wire in the terminal and tighten
the screw securely.
Jumpers
• You will need to set Configuration
Jumpers per the Step-By-Step
diagram. A needle-nose plier may be
required to modify jumper positions
W
What wires do you have?
Determine which step-by-step wiring
diagram below you should use. Make
sure your wires are labeled. This may
require you to find the 'other end' connection for each wire on your heating or
air conditioning equipment and read the label there.
If you have a wire marked "C" it is optional. If you do connect it, the
thermostaDt owwinlllodardafwrompWowwwe.rSformoamnutahlse.coCmw. AirlleM.anTuhalissSeexartcehnAdnsd bDaowttneloraydl.ife.
PG
6
PG
7
Find the set-up diagram for your system
• Find the referenece page with your wiring
diagram and jumper set-up information.
C W RH Go To Page 15
2 Wire
Heat
Remember, the
C
wire is optional.
C W Y RH G C W Y RH RC G
C W RH G
3 Wire
Heat
4 Wire
Heat/Cool
5 Wire
Heat/Cool
W RH A
3 Wire
Zoned
Hot Water
W
W
W
Go
To
PAGE 22
Go To Page 16
Go To Page 17
Go To Page 18
C B or O Y RH G
C B or O W2 Y RH G C W2 W Y Y2 RH G
5 Wire
Heat Pump
4 Wire Heat Pump
w/o Aux Heat
2 stage Cool
2 stage Heat
w/ Aux Heat
B
B
W
2
Go To Page 19
Go To Page 20
Go To Page 21
•
If you combination of wires is not above you can use the
wiring table on pages 24-25 to determine your connections,
or call our USA support line at 1-888-607-5824 for help.
PG
8
Download from Www.Somanuals.com. All Manuals Search And Download.
Mount the 3M-22
Wall
3M-22
• Hold the 3M-22 against the wall, with the wires coming
over the top above terminal block. The 3M-22 will cover the
hole in the wall.
• Position 3M-22 for best appearance. Use the optional stand-
offs if more space for wires is needed behind the 3M-22.
• Attach the base to the wall with the screws provided.
• If you are mounting the base to sheet rock or if you are using
the old mounting holes, use the plastic anchors provided. Drill
a 3/16-in.(4.8mm) hole for the insert at
Wires
each screw location, then mount the base.
W
W
Wall anchor
PG
9
Install AAA Batteries
• The 3M-22 requires 2 AAA batteries to operate .
• Switch MODE switch to OFF and the FAN switch to AUTO.
• Install 2 AAA alkaline batteries according to the polarity noted in
the compartment. LCD segments will go on.
• Press the RESET button (under top cover) to clear transient
program memory. NOTE: Replace the batteries when this LOW
battery indicator appears on the display or once a year.
• Replace top and bottom covers on unit.
-
AAA
+
-
AAA
+
PG 10
Download from Www.Somanuals.com. All Manuals Search And Download.
PG 11
Check Unit
Temperature
Display
Follow these procedures to verify you
have correctly installed the 3M-22.
TEMP
UP button
Mode
Switch
To check Fan: (If you connected the
G wire - fan relay)
• Switch the FAN switch to the ON
position. Verify that air is blowing from
the system. Return to AUTO position
for normal operation.
To check HEAT mode:
Set the mode switch to HEAT.
Set the fan switch to AUTO.
Fan
Switch
TEMP
DOWN button
• Using the TEMP + button raise the Target Temp to 90deg.
Allow the system 2 min to respond.
• Verify that heat is blowing from the system.
To check COOL mode:
• Set the mode switch to COOL.
• Press the TEMP - button to a temp 5 degrees below the room temp.
Allow the system 2 minutes to respond.
• Verify that cool air is blowing from the system.
Congratulations, you have successfully installed your unit.
Please proceed to the OPERATING Guide to initialize the 3M-22.
NOTE: If you have labeled your wires, follow the correct Step-By-Step, and
these Check procedures do not operate your system call support at
1-888-607-5824
PG 12
Download from Www.Somanuals.com. All Manuals Search And Download.
PG 13
Power Options
BATTERIES ONLY - This thermostat can run on batteries only using 2AAA
alkaline batteries. The batteries will last at least 1 year; replace the batteries
once a year or when the low battery icon comes on the display. If the batteries
are not replaced, the thermostat will shut off the HVAC and then stop working.
24VAC - This thermostat can run on the HVAC 24VAC (C wire) if available.
As shown in the wiring diagrams, the C wire is the other side of the 24VAC
heating transformer and can be found where the other thermostat wires
connect at the wall or at the furnace. Do not use the common or ground side
of the line voltage. If the C wire is used, the batteries are then for back-up in
case of power loss only and will last much longer. With the C wire connected,
the thermostat will continue to work if the batteries die or are removed.
Calibration
o
NOTE:Your thermostat comes from the factory calibrated to +/- 1 of actual
temperature. It is an accurate instrument. If you want your thermostat to
display the same temperature as another thermometer in your home, you
can adjust its calibration.
To change the calibration:
Set the Mode switch to HEAT or COOL.
Locate the TIME SET button and press it. The
current calibration factor (+/-) of the 3M-22 will appear
in the LCD display as well as the modified temp.
Push the UP or DOWN arrows until the desired
calibration factor is reached.
Press HOME to save. The new calibrated temperature
Calibrate button
PG 14
will be displayed on the LCD.
Download from Www.Somanuals.com. All Manuals Search And Download.
2 WIRE HEAT Heating GAS MILLIVOLT or 24vac
PG 15
STEP 1 - Connect the R (or RH) wire to the RH terminal on
the 3M-22. This connects the Heater Power to the thermostat.
STEP 2 - Connect the W wire to the W on the 3M-22.
4
6
8
5
7
1 2 3
This connects the heater control line to the 3M-22.
SET JUMPERS
STEP 3 - Set Config jumpers per this diagram.
GAS Milivolt Heat
Your Heater is now connected to the 3M-22.
C
W
R
OPTIONAL POWER
Please Go To Page 9
3M-22
NOTE: Wires marked with
dotted line are optional.
C B O W2 W Y Y2 RH RC G A
3 Wire Heat
PG 16
STEP 1 - Connect the R (or RH) wire to the RH terminal
on the 3M-22. This connects to the Heater Power .
STEP 2 - Connect the W wire to the W terminal on the
3M-22. This connects the heater control line to the
3M-22.
STEP 3 - Connect the G wire to the G terminal on the
thermostat. This connects the Fan to the 3M-22
STEP 4 - Set Config jumpers per this diagram. If you
4
6
8
5
or
7
1 2 3
SET JUMPERS
HVAC SYSTEM
have Electric heat set 5, if you have Gas or Oil set 7.
C
W
R
G
OPTIONAL POWER
Your system is now connected to the 3M-22.
3M-22
Please Go To Page 9
C B O W2 W Y Y2 RH RC G A
Download from Www.Somanuals.com. All Manuals Search And Download.
W Y RH G
4 Wire Heat/Cool
PG 17
STEP 1 - Connect the
thermostat. This connects to the heater control line.
STEP 2 - Connect the wire to the terminal on the
3M-22. This connects to the Cooler compressor.
STEP 3 - Connect the RH or wire to the RH terminal on
the thermostat. This connects the Heater/Cooler Power.
STEP 4 - Connect the wire to the terminal on the
Thermostat. This connects to the Fan.
W
wire to the
W
terminal on the
SET JUMPERS
4
6
5
or
7
Y
Y
1 2 3
8
R
G
G
HVAC SYSTEM
STEP 5 - Set Config jumpers per this diagram. If you
C
W
Y
R
G
have Electric heat set 5, if you have Gas or Oil set 7.
OPTIONAL POWER
Your HVAC system is now connected
to the 3M-22.
Please Go To Page 9
3M-22
C B O W2 W Y Y2 RH RC G A
Terminals
W Y RH RC G
5 Wire Heat/Cool
PG 18
STEP 1 - Connect the
thermostat. This connects to the heater control line.
STEP 2 - Connect the wire to the terminal on the
3M-22. This connects to the Cooler compressor.
STEP 3 - Connect the RH wire to the RH terminal and the
RC wire to the RC terminal on the 3M-22. This connects
the Heater and Cooler Power.
W
wire to the
W
terminal on the
SET JUMPERS
4
6
5
or
7
Y
Y
1 2 3
8
STEP 4 - Connect the
Thermostat. This connects to the Fan.
STEP 5 - Set Config jumpers per this diagram. If you
G
wire to the
G
terminal on the
HVAC SYSTEM
RH RC
C
W
Y
G
have Electric heat set 5, if you have Gas or Oil set 7.
OPTIONAL
Your HVAC system is now connected
to the 3M-22.
3M-22
Terminals
Please Go To Page 9
C B O W2 W Y Y2 RH RC G A
Download from Www.Somanuals.com. All Manuals Search And Download.
PG 19
B
or O Y R G
4 Wire Heat Pump w/o Aux
STEP 1 - Connect O wire to the O terminal or B wire to the B terminal on
the 3M-22. (If you have both O and B - connect O wire to O terminal
DO NOT connect B to B terminal - see pg 24 Trane for B wire terminal)
This connects the change-over valve.
SET JUMPERS
STEP 2 - Connect the Y wire to Y on the 3M-22.
4
6
8
5
7
This connects the Compressor.
STEP 3 - Connect the R wire to RH on the 3M-22.
This connects to the 24vac power.
1 2 3
STEP 4 - Connect the G wire to the G terminal on the
3M-22. This connects the Fan.
HEAT PUMP SYSTEM
OPTIONAL POWER
C
O
B
Y
R
G
STEP 5 - Set Config jumpers per this diagram.
or
or
C B O W2 W Y Y2 RH RC G A
Your HVAC system is now connected
to the 3M-22.
3M-22
Terminals
Please Go To Page 9
PG 20
B
or O W2 Y RH G
5 Wire Heat Pump w/ Aux Heat
STEP 1 - Connect O wire to the O terminal or B wire to the B terminal on
the 3M-22. (If you have both O and B -connect O wire to O terminal DO
NOT connect B to B terminal - see pg 24 Trane for B wire terminal)
STEP 2 - Connect the W2 wire to W2 on the 3M-22.
SET JUMPERS
STEP 3 - Connect the Y wire to Y on the 3M-22.
4
6
5
7
?
STEP 4 - Connect the R wire to RH on the 3M-22.
STEP 5 - Connect the G wire to G on the 3M-22.
STEP 6 - Set Config jumpers per this diagram.
Set jumper 1 if you have Gas or Oil aux heat.
1 2 3
8
HEAT PUMP SYSTEM
W2
OPTIONAL POWER
C
O
B
Y
R
G
Your HVAC system is now connected
to the 3M-22.
or
or
C B O W2 W Y Y2
Please Go To Page 9
3M-22
Terminals
Download from Www.Somanuals.com. All Manuals Search And DownloRadH. RC G A
W2 W Y Y2 RH RC G 2 Stage Heat and Cool
PG 21
STEP 1 - Connect the
W2 on the 3M-22. This connects 2 stages of heat.
STEP 2 - Connect the wire to the terminal and Y2 wire
to Y2 on the 3M-22. This connects 2 stages of cool.
STEP 3 - Connect the RH or wire to the RH terminal on
the thermostat. This connects the Heater/Cooler Power.
STEP 4 - Connect the wire to the terminal on the
Thermostat. This connects to the Fan.
W
wire to the
W
terminal and W2 to
Y
Y
SET JUMPERS
R
4
6
8
5
7
or
1 2 3
G
G
HVAC SYSTEM
Y2 RH RC
STEP 5 - Set Config jumpers per this diagram. If you
W2
C
W
Y
G
have Electric heat set 5, if you have Gas or Oil set 7.
Your HVAC system is now connected
to the 3M-22.
OPTIONAL
POWER
Please Go To Page 9
3M-22
C B O W2 W Y Y2 RH RC G A
Terminals
PG 22
W RH [A?]
3 Zoned Hot Water - Motor Valve
Step 1 - based on your valve type
SET JUMPERS
Motor driven Valve- Connect the R (or RH) wire to the RH
terminal on the 3M-22. Connect the W wire to the W terminal
on the 3M-22. Connect the remaining wire to the A terminal.
Solenoid valve -Connect the R (or RH) wire to the RH
terminal on the 3M-22. Connect the W wire to the A terminal
on the 3M-22. Connect the remaining wire to the W
terminal.
1 2 3
4
6
8
5
7
Motor Valve
STEP 2 - Set Config jumpers per this diagram.
W
R
A
Your system is now connected to the 3M-22.
3M-22
Terminals
Please Go To Page 9
C B O W2 W Y Y2 RH RC G A
Download from Www.Somanuals.com. All Manuals Search And Download.
PG 23
3M-22 Features
This thermostat can be used with all millivolt and 24VAC heating and cooling systems. It
cannot be used with line voltage systems. This thermostat is digital and your desired heat or
cool temperatures can easily be set on the large screen with the +/- buttons on the front. A
minimum 4 minute off time protects heating and cooling systems from damage.
This thermostat uses a new technique called sequential staging for more comfort with
faster reaction to requested temperature changes. When using a heat pump with Aux heat, if
the heat pump cannot keep up and/or is
defective, remove jumper from position 8 and put
jumper on position 6 and the Aux heat will then
be your only source of heat. Be sure to restore it
to PUMP when the pump is again operational as
aux heat is more expensive than pump heat.
PG 24
Wire Reference
Your Wires
Filtrete Terminal
R or V or VR RH and RC Single power for HEAT and COOL
RH or 4
RH Power for HEAT (RH not connected to RC)
RC
W
RC Power for COOL (RH not connected to RC)
W Heat control
W2
?
Y
Y2
G or F
C or X
E
L
T
W2 2nd stage HEAT or heat pump auxiliary heat
A 3rd wire for zoned hot water heat (see zoned)
Y COOL control
B and O
NOTE: If
Y2 2nd stage COOL control
there are both
B and O wires
(Trane pump
products)
G FAN control
C Common 24VAC power (to power thermostat)
Emergency heat (do not connect, tape off)
System monitor (do not connect, tape off)
Outdoor sensor (do not connect, tape off)
DO NOT
CONNECT B
to B terminal,
connect B to C
B or
B Heat pump changeover (cool to heat, powered in heat)
O Heat pump changeover (heat to cool, powered in cool)
O
Download from Www.Somanuals.com. All Manuals Search And Download.
terminal
B and O
SEE NOTE
PG 25
Wire Reference cont
Zoned Systems
Your Wires
Filtrete Terminal
Your Wires
Filtrete Terminal
2 wire Zoned Hot Water
R
W
RH
W
Lennox Heat Pump
V or VR or R
M or Y
RH
Y
3 Wire Zoned Hot Water
Motor Driven Valves
Y or W or W2
F or G
W2
G
O
C
R
W
RH
W
R or O
X or X2 or C
Y (the 3rd wire) A
Trane Products [American Standard]
3 Wire Zoned Hot Water
Solenoid Valves
B
C
W or W1
W2
R
RH
A
W
Y (the 3rd wire)
W
PG 26
RESET UNIT
Jumper Reference
AFTER CHANGING JUMPERS
GAS/ELEC HEAT
SELECT
CLOSED
OPEN
Configuration jumpers allow your
3M-22 to be adapted to many
different HVAC control applications.
SINGLE
HVAC
POWER(R)
POWER
4
ELECTRIC
POWER RH
POWER RC
OR PUMP
CLOSED
5
NORM/PUMP/AUX
SELECT
AUX
TYPE
12hr clock
24hr clock
CELSIUS
FAHRENHEIT
OR
GAS OR OIL
CLOSED
CLOSED
OPEN
OPEN
HEAT PUMP'S
HEAT
CLOSED
7
PUMP AUX
6
8
AUX ONLY
24hr
CELSIUS
3
GAS OR OIL
HEAT
PUMP
1
2
CLOSED
PUMP AUX
ELECT
12 hr
FAHRENHEIT
OPEN
Customer Support: 888-607-5824 or
Download from Www.SomaPnurailns.tceomd.iAnll MCahniunaals Search And Download.
1002-005
|