Model 1134
AccuRead
Blood Pressure Monitor & Clock
User Manual
Distributed by:
The Lumiscope Co., Inc
Repair Department: 1-800-672-8293
Made and Printed In China
Download from Www.Somanuals.com. All Manuals Search And Download.
2
Table of Contents
Introduction
3
Introduction.................................................................... 3
How This Monitor Works.................................................. 4
About Blood Pressure ..................................................... 5
Parts Identification ......................................................... 6
Unit Display Symbols...................................................... 7
Unit Display Explanation ................................................. 8
Features.......................................................................... 9
Installing the Batteries.................................................. 10
Correct Measuring Posture............................................ 11
Applying the Cuff ....................................................12, 13
Measurement Procedures.............................................. 14
WHO Lighted Indicator.................................................. 15
Irregular Heartbeat Detection........................................ 16
Heartbeat Readings ...................................................... 17
Memory Recall.............................................................. 18
Average Recall............................................................... 19
Clock Settings.........................................................20, 21
Maintaining & Storing Unit............................................ 22
Troubleshooting ............................................................ 23
Specifications ............................................................... 24
Warranty....................................................................... 25
Congratulations on your purchase of the new Lumiscope
model 1134. This fully-automatic, blood pressure
monitor is both easy-to-use and ideally suited for daily
measurements. The large display includes systolic blood
pressure reading, diastolic blood pressure reading and
the pulse rate, all clearly shown at the completion of
each reading.
You can store up to 99 measurements in each of the unit's
4 memory zones, ideal for users who want to monitor and
track their blood pressure on a regular basis. The 1134 is
compact and portable, making it perfect for home use and
travel.
Blood pressure measurements determined with your 1134
are equivalent to those obtained by a trained observer
using cuff/stethoscope auscultation method, within the
limits prescribed by the American National Standard,
Electronic or Automated Sphygmomanometers.
Please read this manual carefully before use. For specific
information on your own blood pressure, contact your
physician. Please be sure to keep this manual.
Download from Www.Somanuals.com. All Manuals Search And Download.
4
How the 1134 Works
About Blood Pressure
5
Your model 1134 uses the oscillometric method to detect
your blood pressure. Before the cuff starts inflating,
the device will establish a baseline cuff pressure, which
is equivalent to the air pressure. The measurement of
your blood pressure is based on this baseline pressure.
After the cuff inflates to block your blood in the artery,
the deflation process starts. During the deflation of the
cuff, the monitor is detecting the pressure oscillations
generated by the beat-to-beat pulsatile. Any muscle
movement during this period of time will cause
measurement error. After detecting the amplitude and
the slope of the pressure oscillations during the deflation
process, your 1134 will determine the systolic and
diastolic pressures for you; and your pulse rate is detected
at the same time.
What is Blood Pressure?
Blood pressure is the pressure exerted on the artery
tube while blood flows through the arteries. The pressure
measured when the heart contracts and sends blood
out of the heart is systolic (highest) blood pressure. The
pressure measured when the heart dilates with blood
flowing back into the heart is called diastolic (lowest)
blood pressure.
Why Measure Your Blood Pressure?
Among the various health problems afflicting people today,
problems associated with high blood pressure are by far
the most common. High blood pressure's dangerously
strong correlation with cardiovascular disease has made
measuring blood pressure a necessity for identifying those
at risk.
Download from Www.Somanuals.com. All Manuals Search And Download.
Parts Identification
6
Unit Display Symbols
7
Display Symbols
Date/
Time
KPa
Systolic
Pressure
AVG
1
2
3
4
Diastolic
Pressure
Start/Power
Pre-formed Cuff
Air Tube
Pulse
Value
Memory Zone
Select
Average Selection
Memory Select
WHO Indicator
USB Plug /PC Link
Cuff Plug Outlet
AC Adaptor Outlet
Download from Www.Somanuals.com. All Manuals Search And Download.
Unit Display Explanation
Features
8
9
Functional
• One touch operation
Display Explanations
User 1-4: Appears when the unit is being operated by
User 1 through User 4.
• Large LCD display
• Irregular Heartbeat Detector: This unit can detect a
Low Battery Indicator: Appears when the batteries are
low or need replacement.
disturbance in the regular rhythm of the heartbeat, which
may cause or indicate cardiovascular disease.
• Automatically determines the ideal air pressure for the
cuff inflation.
Pulse Symbol: Shows the pulse rate per minute.
Kilopascal: Measures the amount of air pressure that is
being inflated into the pre-formed cuff.
KPa
Memory Average: Shows the average values for an hour, a
day, a week, a month and all readings in the Memory Zone.
• 4-person memory zones with 99-readings each.
• 2 Modes: Blood Pressure Mode & Clock Mode.
• 4 Alarm Clock settings.
AVG
Memory Recall: Shows the past readings. (1~99
readings available)
• 5-Mode Average Function: Sets the average for up to 99
readings for each zone by hour, day, week, month and
overall.
Memory : Holds the memory reads for User 1 through
User 4, for up to 99 readings each.
Irregular Heartbeat Detector: Indicates when an
irregular heartbeat is detected.
• WHO Indicator: Shows 6 different light signs to
indicate your state of health based on the World Health
Organization guidelines.
WHO Light Indicator: Displays six different light signs
of Blood Pressure readings against the guidelines set by
the World Health Organization. (See Pg. 15)
• Auto shut-off: Unit automatically turns off in 3 minutes;
power saving.
If anyone of these error messages occur while taking your
reading, please see the Troubleshooting section. (Pg 23)
• Operated by 4 "AA" batteries or AC/DC adapter.
Fails to Inflate
Deflates too fast or too slowly.
Note: This unit also offers PC-LINK software. If you order
this function, you will receive a separate package including
a CD and a connection line with a USB plug. You may order
A. Arm movement caused error in reading
B. Interference signal around the BPM
Incorrect measured result
Download from Www.Somanuals.com. All Manuals Search And Download.
10
Installing the Batteries
11
Correct Measuring Posture
1. Place your elbow on a table
so that the cuff is at the same
level as your heart. (Fig. A.)
1. To insert the batteries
A. Press down on the latch and lift the cover towards you
to open the battery compartment.
Fig. A
Note: The level of your heart is
slightly below your armpit.
B. Insert 4 "AA" batteries as indicated. Make sure to match
polarities (+, –) on the batteries.
Relax your entire body,
especially the area between
your elbow and fingers.
C. Replace the battery cover by inserting the two hooks at
the bottom into the slot, then push on the top area.
2. If the cuff is not at the same
level as your heart or if
Note: Please remove
batteries when not in
use for an extended
period of time. Do not
dispose batteries with
household garbage.
Fig. B
you can not keep your arm
completely still throughout the
reading, use a soft object such
as a folded towel to support
your arm. (Fig. B) Do not
allow hard objects to come in
contact with the wrist cuff.
2. To Connect the AC/DC Adapter
A. Plug the AC/DC adapter (6V 500mA), into the jack
located at the bottom of this
3. Turn your palm upwards.
Fig. C
unit. (shown in the diagram).
4. Sit upright in a chair, and take
5-6 deep breaths.
(X)
B. Use only the adapter
included with this unit.
Avoid leaning back or
crossing your legs while the
measurement is being taken.
(Fig. C)
Note: Remove batteries
when using the AC
adapter for an extended
period of time.
Download from Www.Somanuals.com. All Manuals Search And Download.
12
13
Applying the Cuff
Applying the Cuff
D. To have a secure fit, pull the end of the cuff towards
you, wrap it over, then press it for closure. If the Index
line falls within the OK range, indicated at the edge of
the cuff, this cuff is suitable for your use. If the Index
line falls out of the OK range, you may need a cuff
with larger circumference.
To apply the cuff
A. Plug the end of the tubing on the
cuff into the connector at the base
of the monitor.
This cuff fits arm sizes 9.2" - 18.2".
B. Remove any clothing that restricts the upper left arm.
Wrap the cuff around your upper left arm. The rubber
tube should point in the direction of your hand. The
bottom edge of the cuff should be 0.8" ~ 1.2" (2~3
cm) above your elbow with the tube positioned over the
middle of your arm.
Main
Artery
E. Position your arm so that the cuff is aligned at heart
level, as shown in the diagram.
C. Position the artery mark (
) over the main artery (on
the inside of your arm) in the upper arm.
Main
Artery
Note: To locate the main artery, press two fingers approximately 1" (2cm)
above the bend of your elbow on the inside of your left arm
Download from Www.Somanuals.com. All Manuals Search And Download.
14
Measurement Procedures
WHO Lighted Indicator
15
To start the measurement
Note: In order to get your correct measurement result and to avoid
erroneous measurements you should be seated quietly, your arm, hand,
and fingers should be still during measurement procedure.
Showing levels of Blood Pressure Reading
Standards for assessing high blood pressure, without
regard to age, have been established by the World Health
Organization (WHO), as shown in the chart as below. This
unit offers 6-color light signs after user's measuring. From
the light sign, it will help users to find out their health
situation. Different levels show the corresponding light color.
A. Push the "PAGE" button to select one of the four
Memory Zones. Then push "POWER" twice. It will then
display a "FLASHING 0". After a few moments the
unit will automatically inflate displaying the increasing
pressure reading.
Example: If your Blood
Pressure reading is
122/75, then light sign
will indicate the color
Blue Green which means
your reading is Normal
ON/OFF
Light Sign
Indicator
Blood Pressure
Reading
Memory
Power
Zone
Pressure
Flashing 0
• Grade 1 Hypertension — Purple
• Grade 2 Hypertension — Yellow
• Grade 3 Hypertension — Red
• Optimal – Blue
• Normal – Sky Blue
• High-Normal – Green
Reading
B. After the unit reaches its desired pressure, the cuff will
slowly deflate. During deflation, the unit will beep. Once
the cuff has been fully deflated, your blood pressure
measurement will be displayed on the LCD screen.
Grade 3 hypertenslon (severe)
(Red)
180
Grade 2 hypertenslon (moderate)
(Yellow)
160
Grade 1 hypertenslon (mlld)
(Purple)
140
130
120
(Green)
Hlgh-normal
Normal
(Sky Blue)
(Blue)
Optlmal
Maximum Pressure
Reading
Pressure
Deflating
Blood Pressure
Reading
80 85
90
100
110
Diastolic Pressure mmHg
Download from Www.Somanuals.com. All Manuals Search And Download.
Irregular Heartbeat Dectection
Heartbeat Readings
16
17
An irregular heartbeat may cause or indicate
cardiovascular disease. This unit has a unique function
that alerts the user to the presence of an irregular
heartbeat.
Regular Heartbeat reading but below normal
When taking your blood pressure reading, if your reading
displays a value below 60 beats/sec, then the unit will
display the Pulse Value and "LO" symbols alternately.
Example: (58/LO)
Irregular Heartbeat reading
When taking your blood pressure reading, If you are
experiencing an irregular heartbeat the unit will display
the Pulse Value and "IH" symbols alternately.
Example: (90/IH)
Regular Heartbeat reading but above normal
When taking your Blood Pressure reading, if your reading
displays a value above 100 beats/sec, then the unit will
display the Pulse Value and "HI" symbols alternately.
Example: (102/HI)
Note: It is advised that you consult your physician if the irregular
heartbeat symbol "IH" appears often.
Download from Www.Somanuals.com. All Manuals Search And Download.
18
Average Recall
19
Memory Recall
This unique monitor automatically offers a set of five
To see the previously measured values
average values: (Hour, Day, Week, Month and All). It offers
you or your doctor an easy way to find out the cariation in
Systolic, Diastolic and Pulse values.
A. Push the "PAGE" button to select one of the four
Memory Zones.
To see the average of previously measured values
B. Once one of the four Memory Zones has been selected,
push the "MEMO" button twice. The first blood pressure
reading will be displayed.
A. Push the "PAGE" button to select one of the four
Memory Zones.
C. To view additional readings, push the "MEMO" button
successively to go through the various readings. (1~99)
B. Once one of the four Memory Zones have been selected.
Push the "AVG" button twice. The average for the Hour
will be displayed.
To delete the memory
AVG
AVG
AVG
AVG
AVG
A. Push the "PAGE" button to select one of the four
Memory Zones.
B. Once one of the four Memory Zones has been selected,
hold the "MEMO" & "PAGE" button together for 5
seconds. The LCD will dispaly "ALL EE" and the
decreasing memory recall number simultaneously.
C. To view the averages for the Day, Week, Month & All,
keep pushing the "AVG" button.
D. To view another Memory Zone, push the "PAGE" button
once, then push the "AVG" button to view the averages.
Note: The most recent reading is shown first. After all 99 readings are
recorded, new readings replace the oldest reading in memory.
Download from Www.Somanuals.com. All Manuals Search And Download.
20
21
Clock Settings
Clock Settings
1. To set time and date
E. During the setting, if there is any confusion you may
simply press the " " button and this unit will re-
A. Press the " " button and hold for at least 5 seconds. You
can start setting the year when the "YEAR" digit blinks.
display TIMER function.
B. Then press " MEMO" to increase the year and
F. This unit offers 4-Alarm setting. Each alarm will ring for
45 seconds, or you may stop the alarm by pressing the
"PAGE " to decrease the year.
"
" button.
C. After finishing "YEAR" setting, press " " button again.
Now you can adjust Month/Date/Hour and Minute
digits as you desire.
2. How to set Alarm Clock
A. Press " " button and hold for at least 5 seconds. The
"YEAR" digit blinks. At this point, adjust the Date/Time
accordingly.
B. The LCD display blinks the word "ON". You may press
"
" and adjust desired time for the alarm by pressing
the "MEMO" or "PAGE" buttons.
C. Keep LCD display in the "ON" position, and press "
button to continue second alarm setting.
"
D. If you need to stop alarm setting, you may press.
"MEMO" or "PAGE" buttons to let the LCD display transfer
to the "OFF" position. Then the Alarm setting will stop.
Download from Www.Somanuals.com. All Manuals Search And Download.
Maintaining & Storing Unit
22
Troubleshooting
23
A. Use a dry, soft cloth to clean the unit. If desired, use a
cloth lightly dampened with tap water.
Problem
Check Point
Solution
Nothing is displayed
when the "ON/OFF"
key is pressed.
Are the batteries
exhausted?
Replace the
batteries with
new ones.
B. Do not use alcohol, benzene thinner or other harsh
chemicals to clean the device or cuff.
Have the batteries
polarity been
positioned
Re-insert the
batteries in the
correct position.
C. Before measuring, please wash your hands. Do not wash
or wet the arm cuff.
correctly?
Fails to inflate
Make sure the cuff
is connected to
the unit properly.
"Err P" shown on LCD
D. When storing this unit, keep it away from direct
sunlight, high humidity or dust.
Note: If the unit is being stored for a long period of time,
please remove the batteries before storing to avoid leaking.
Check air tube. If
broken, replace it.
Deflates too fast
Return for
servicing.
"Err 1" shown on LCD
Movement has
occurred.
Keep still
when taking
measurement.
"Err 2" shown on LCD
Signal interference
around BPM
Remove
interference
source. example:
magnets & cell
phones.
Incorrect results
Measure again
"Err 3" shown on LCD
Note: If correct measurement is impossible after troubleshooting, consult
store of purchase or Lumiscope repair department. (Do not disassemble
unit). In some rare cases, there may be error due to the physical condition
of the person. In such cases, please consult your physician. If the clock
doesn't show on the LCD, please adjust the clock settings.
Download from Www.Somanuals.com. All Manuals Search And Download.
Two Year Limited Warranty
24
Specifications
25
Lumiscope guarantees this product free from defects in material and
Model
: 1134
workmanship for a period of two years from the date of purchase, except
as noted below:
Power source
: 4 "AA" Alkaline batteries or AC/DC
adapter
Measurement method : Oscillometric
This Lumiscope product warranty does not cover damage caused by misuse
or abuse, the attachment of any unauthorized accessory, alteration to the
product, or any other conditions whatsoever that are beyond the control of
Lumiscope. Lumiscope shall not be responsible for any type of incidental,
consequential, or special damage. All implied warranties, including, but
not limited to those implied warranties of fitness and merchantability,
are limited to the total duration of two years from the original date of
purchase.
Measurement range
: Pressure: 20~280 mmHg
Pulse: 40~195 beats/minute
Accuracy
: Pressure: ±3 mmHg
Pulse: within ±5% of reading
Pressure sensor
Inflation
: Semi-conductor
: Pump driven
Deflation
: Automatic Pressure release valve
: 3 minutes after last key operation
To obtain warranty service on your Lumiscope Blood Pressure Monitor,
please contact the Lumiscope Repair Department at 1-800-672-8293
handling. Please make checks payable to The Lumiscope Co., Inc.
Upon receipt, Lumiscope will repair or replace, as appropriate, this blood
pressure monitor and return it to you. Warranty is solely through the
Lumiscope Repair Department. Service of this product by anyone other
than the Lumiscope Repair Department voids warranty.
Auto shut-off
Operating environment : 50˚F~104˚F / 30%~85% RH max.
Storage environment
: -20˚C~60˚C (14˚F~140˚F)
10%~95% RH max.
Weight
: 344g (w/o batteries), cuff 120g
: 9.2" ~18.2"
In the event that Lumiscope does not abide by the terms of this warranty,
the consumer may seek breach of contract remedies in the New York State
Federal courts of law. This warranty gives you specific legal rights and you
may also have other rights which vary from state to state.
Arm circumference
Users
: Adults
Dimensions
PC-Link
: 5.3" (L) x 4.8" (W) x 6"(H)
: Via USB plug & software. (available
separately)
Some states do not allow the exclusion or limitation of incidental or
consequential damages, so the above limitation may not apply to you.
*Specifications are subject to change without notice.
Download from Www.Somanuals.com. All Manuals Search And Download.
|