565DG Drop Arm - 565TG Tilt-in-Space
®
Ortho-Biotic Preferred Care Recliners
Operating Instructions
GF0500044A05RevA05
© Graham-Field Health Products 2005
IMPORTANT: READ THIS MANUAL BEFORE OPERATING
YOUR ORTHO-BIOTIC PREFERRED CARE RECLINER
Download from Www.Somanuals.com. All Manuals Search And Download.
UNPACKING INSTRUCTIONS
1. Unpack and inspect contents for shipping 2. Do not remove the shipping support which is
damage or missing parts. If parts are
damaged or missing, contact your dealer
immediately. The contents of this package
should be:
attached to the recliner’s upholstered back
until after the recliner’s upholstered back has
been assembled to the chair.
3. Save this booklet in a safe place for future
reference.
• One (1) Recliner frame with upholstered
seat.
• One (1) Upholstered back.
• Two (2) Upholstered side panels.
• Two (2) Pins with wire rings.
565DG/565TG Ortho-Biotic Preferred Care® Recliners Operating Instructions
3
Download from Www.Somanuals.com. All Manuals Search And Download.
Upholstered
BACK ASSEMBLY
Back Cushion
Elastic Band
NOTE:Do not remove the shipping support which
is attached to the recliners upholstered back
until after the recliner's upholstered back
has been assembled to chair.
Figure 1
1. Obtain upholstered back assembly. Remove
the upholstered cushion from the metal back
frame (See fig. 1).
Shipping
Support
2. Remove pins and wire rings from frame
(See fig 1).
3. Slide back tubes onto receiving tubes on
frame and tap down until holes in back line up
with holes in frame (See fig. 1).
Clevis Pin
Wire Ring
Frame
4. Replace pins and wire rings. Remove the
shipping support and discard (See fig 1).
Receiving Tubes
Key Ring
5. Slide the lower elastic band on back to cover
pins. Position other straps evenly. The 2" elastic
bands can be adjusted for custom comfort.
6. At the bottom of the cushion you will find two
elastic straps with key rings on the ends (one
on each side). Replace back cushion over
metal frame. Attach each ring to the hook on
the frame next to the seat rings (See fig 2).
Strap
Hook
Figure 2
Side Panel
SIDE PANEL ASSEMBLY
1. Face the side panel cut out towards the front
of the chair.
Cut-Out
2. Line up the panel’s spring clips with the round
tubes on the frame. Push against the panels
side until the clips are secured to the frame.
Slide
3. Slide the panel up or down until the panel is
flush with the top of the frame (See fig 3).
Push
Here
4. Repeat above steps for the opposite side.
Figure 3
4
565DG/565TG Ortho-Biotic Preferred Care® Recliners Operating Instructions
Download from Www.Somanuals.com. All Manuals Search And Download.
CASTER OPERATION
To unlock
NOTE:This chair is equipped with four swivel
casters for improved maneuverability. The
rear casters are also equipped with locking
features.
To lock swivel
and wheel
Figure 4
Lock: To prevent the rear casters from swiveling
and wheel turning, step on the rear pedal of the
caster until it latches (See fig 4).
Unlock: Step on middle button to unlatch
(See fig. 4).
To lock swivel
SWIVEL LOCK PEDAL OPERATION
NOTE:The swivel lock feature will aid the chair in
rolling straight.
Figure 5
Lock: To engage, push down on black swivel lock
pedal and roll the recliner forward (See fig. 5).
Unlock: Lift on the side of the pedal.
DROP ARM OPERATION
Warning: Before operating, insure that the
patients extremities (i.e., hands, legs, limbs)
are clear of the path of the armrest.
NOTE:There are three armrest positions. To lower
or raise the armrest, locate the push button
on the side of the chair. Press the button to
release and adjust armrest to the desired
position (See fig. 6).
Figure 6
565DG/565TG Ortho-Biotic Preferred Care® Recliners Operating Instructions
5
Download from Www.Somanuals.com. All Manuals Search And Download.
CORRECT SEAT POSITIONING
OCCUPANT OPERATED
To recline, place hands on armrests and lean
against the back until the desired position is
obtained (See fig. 7).
To
Recline
To return to seated position, place hands on
armrests and lean forward while pressing legs
down against the legrest
To
Return
ATTENDANT OPERATED
Release the recliners position stop.
Use handgrip to adjust recliner to desired position.
Engage recliner stop.
Figure 7
OPERATION OF THE POSITION MECHANISM
NOTE:Casters must be locked.
1. To hold recliner in any position, rotate handle
to point up (See fig. 8).
2. To release position mechanism, turn the
handle to point down (See fig. 9).
Figure 8
NOTE:The position mechanism is factory set. If the
position mechanism does not hold, follow
Adjustment Instructions for the position
mechanism. The plate has 5 position marks
for repeatable positions (See fig. 13).
Figure 9
6
565DG/565TG Ortho-Biotic Preferred Care® Recliners Operating Instructions
Download from Www.Somanuals.com. All Manuals Search And Download.
565G UPHOLSTERY REMOVAL AND
REPLACEMENT
BACK CUSHION
To remove: Release the two elastic straps which
hold the button of the cushion to the back frame
with small wire clips (See fig. 10).
Grip top of cushion near back frame handgrips
and slide up and off.
Figure 10
To replace: Reverse procedure.
SEAT-LEG CUSHION
Frame
Key Ring
To remove: Release the two elastic straps which
hold the cushion to the back frame with small
wire rings (See fig. 11).
Adjust the chair into the semi-recline position.
Strap
Flip the seat cushion forward and release the
two hooks which hold the cushion to legrest
frame (See fig. 12).
Hook
Figure 11
Slide the cushion downward and forward.
To replace: Reverse procedure.
ARM PANELS
To remove: Grip the steel rod at the bottom of
the side panel, located near the front of the side
frame. Gently slide the rod backward. Flex the
rod slightly until it disengages (See fig. 12).
Detach the four screws from under the side
frame arm plate.
To replace: Reverse procedure.
Figure 12
565DG/565TG Ortho-Biotic Preferred Care® Recliners Operating Instructions
7
Download from Www.Somanuals.com. All Manuals Search And Download.
RECLINER POSITIONING MECHANISM
TROUBLE-SHOOTING
ADJUSTMENT INSTRUCTIONS FOR POSITION
MECHANISM
NOTE:Never lubricate the position
mechanism assembly.
Clevis ring and
wire ring
1. Turn the position adjustment handle down to
the release position, and remove clevis pin
and wire ring from top of assembly.
(See fig. 13).
Slide
2. Slide positioning plate up, and turn square
washer clockwise until snug (See fig. 13).
Positioning plate
3. Slide the positioning plate down over square
washer. Replace clevis pin and wire ring.
4. The position mechanism's handle should
engage at about the halt way point. If more
tension is desired, repeat the above procedure.
Square washer
Figure 13
8
565DG/565TG Ortho-Biotic Preferred Care® Recliners Operating Instructions
Download from Www.Somanuals.com. All Manuals Search And Download.
TILT-IN-SPACE GAS SPRING TROUBLESHOOTING
PROBLEM:
If the chair actuates without squeezing the release
lever, the cable assembly needs to be adjusted.
Bracket Assembly
Cable
Gas Spring Cylinder
CORRECTION:
1. Lean the chair on its side and remove clevis
pin and wire rue ring that secure the top of
the gas spring to the frame. Do not remove
the cable.
In
Out
2. Loosen the nut above the gas spring bracket.
Rotate the gas spring out of the bracket
(counterclockwise) 1/2 turn. Retighten nut on
bracket, and reassemble the gas spring back
to the frame. Check that cable is snapped into
bracket (See fig. 14).
Nut
Rue Ring
Figure 14
Clevis Pin
3. Test the operation of chair. If the chair still
actuates without squeezing release lever,
repeat the above procedure.
PROBLEM:
If the chair does not actuate with a person in the
chair while squeezing the release lever and
pushing on the back, then the cable is too loose
and the assembly needs to be adjusted.
Engage as shown
CORRECTION:
1. Ensure the cable is properly engaged onto the
bracket assembly. If cable is not engaged on
bracket, engage as shown in figure 15.
2. With a person in the chair, recheck cable.
If problem persists, go to step 3.
Cable
3. Lean the chair on its side and remove clevis
pin and wire ring that secure the top of the gas
spring to the frame. Do not remove the cable.
Bracket Assembly
4. Loosen the nut above the gas spring bracket.
Rotate the gas spring into the bracket
(clockwise) 1/2 turn. Retighten nut on bracket
and reassemble the gas spring back to the
frame (See fig. 14).
Figure 15
5. Test the operation of chair. If the chair does
not actuate with a person in the chair while
squeezing the release lever, repeat steps 3-5.
565DG/565TG Ortho-Biotic Preferred Care® Recliners Operating Instructions
9
Download from Www.Somanuals.com. All Manuals Search And Download.
Release Lever
Under Cusion
CORRECT TILT POSITIONING
FOR TILT-IN-SPACE
NOTE:The Tilt chair is attendant operated only.
For chair to operate properly, a person
must be in the chair.
Push Handle
To tilt the chair back:
1. Stand behind the chair, and locate the release
lever under the push handle.
2. Squeeze the lever while pushing down on the
back. Once the desired position is attained,
release the lever to lock into position
(See fig. 16).
Up Position
To bring the chair up:
1. Stand behind the chair, and locate the release
lever under the push handle.
2. Squeeze the release lever and lift the back up.
Once the desired position is attained, release
the lever to lock into position (See fig. 16).
LEGREST OPERATION
FOR TILT-IN-SPACE
To lift legrest:
Step on the front of the foot pedal, located on the
side of the chair, until it locks in place (See fig. 16).
Legrest Down
To lower legrest:
Step on the back of the foot pedal.
Legrest Up
Note: The legrest is easier to operate when the
chair is in its fully tilted position, however
legrest will operate in any position of tilt.
Figure 16
10
565DG/565TG Ortho-Biotic Preferred Care® Recliners Operating Instructions
Download from Www.Somanuals.com. All Manuals Search And Download.
U.S.A., Corporate Headquarters:
Graham-Field Health Products
2935 Northeast Parkway
Atlanta, Georgia 30360
telephone: 800-347-5678, 770-447-1609
fax: 800-726-0601, 678-291-3232
Download from Www.Somanuals.com. All Manuals Search And Download.
|