UNPACKING INSTRUCTIONS  
1. Unpack and inspect contents for shipping 2. Do not remove the shipping support which is  
damage or missing parts. If parts are  
damaged or missing, contact your dealer  
immediately. The contents of this package  
should be:  
attached to the recliner’s upholstered back  
until after the recliner’s upholstered back has  
been assembled to the chair.  
3. Save this booklet in a safe place for future  
reference.  
• One (1) Recliner frame with upholstered  
seat.  
• One (1) Upholstered back.  
• Two (2) Upholstered side panels.  
• Two (2) Pins with wire rings.  
565DG/565TG Ortho-Biotic Preferred Care® Recliners Operating Instructions  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
Upholstered  
BACK ASSEMBLY  
Back Cushion  
Elastic Band  
NOTE:Do not remove the shipping support which  
is attached to the recliners upholstered back  
until after the recliner's upholstered back  
has been assembled to chair.  
Figure 1  
1. Obtain upholstered back assembly. Remove  
the upholstered cushion from the metal back  
frame (See fig. 1).  
Shipping  
Support  
2. Remove pins and wire rings from frame  
(See fig 1).  
3. Slide back tubes onto receiving tubes on  
frame and tap down until holes in back line up  
with holes in frame (See fig. 1).  
Clevis Pin  
Wire Ring  
Frame  
4. Replace pins and wire rings. Remove the  
shipping support and discard (See fig 1).  
Receiving Tubes  
Key Ring  
5. Slide the lower elastic band on back to cover  
pins. Position other straps evenly. The 2" elastic  
bands can be adjusted for custom comfort.  
6. At the bottom of the cushion you will find two  
elastic straps with key rings on the ends (one  
on each side). Replace back cushion over  
metal frame. Attach each ring to the hook on  
the frame next to the seat rings (See fig 2).  
Strap  
Hook  
Figure 2  
Side Panel  
SIDE PANEL ASSEMBLY  
1. Face the side panel cut out towards the front  
of the chair.  
Cut-Out  
2. Line up the panel’s spring clips with the round  
tubes on the frame. Push against the panels  
side until the clips are secured to the frame.  
Slide  
3. Slide the panel up or down until the panel is  
flush with the top of the frame (See fig 3).  
Push  
Here  
4. Repeat above steps for the opposite side.  
Figure 3  
4
565DG/565TG Ortho-Biotic Preferred Care® Recliners Operating Instructions  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CASTER OPERATION  
To unlock  
NOTE:This chair is equipped with four swivel  
casters for improved maneuverability. The  
rear casters are also equipped with locking  
features.  
To lock swivel  
and wheel  
Figure 4  
Lock: To prevent the rear casters from swiveling  
and wheel turning, step on the rear pedal of the  
caster until it latches (See fig 4).  
Unlock: Step on middle button to unlatch  
(See fig. 4).  
To lock swivel  
SWIVEL LOCK PEDAL OPERATION  
NOTE:The swivel lock feature will aid the chair in  
rolling straight.  
Figure 5  
Lock: To engage, push down on black swivel lock  
pedal and roll the recliner forward (See fig. 5).  
Unlock: Lift on the side of the pedal.  
DROP ARM OPERATION  
Warning: Before operating, insure that the  
patients extremities (i.e., hands, legs, limbs)  
are clear of the path of the armrest.  
NOTE:There are three armrest positions. To lower  
or raise the armrest, locate the push button  
on the side of the chair. Press the button to  
release and adjust armrest to the desired  
position (See fig. 6).  
Figure 6  
565DG/565TG Ortho-Biotic Preferred Care® Recliners Operating Instructions  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
CORRECT SEAT POSITIONING  
OCCUPANT OPERATED  
To recline, place hands on armrests and lean  
against the back until the desired position is  
obtained (See fig. 7).  
To  
Recline  
To return to seated position, place hands on  
armrests and lean forward while pressing legs  
down against the legrest  
To  
Return  
ATTENDANT OPERATED  
Release the recliners position stop.  
Use handgrip to adjust recliner to desired position.  
Engage recliner stop.  
Figure 7  
OPERATION OF THE POSITION MECHANISM  
NOTE:Casters must be locked.  
1. To hold recliner in any position, rotate handle  
to point up (See fig. 8).  
2. To release position mechanism, turn the  
handle to point down (See fig. 9).  
Figure 8  
NOTE:The position mechanism is factory set. If the  
position mechanism does not hold, follow  
Adjustment Instructions for the position  
mechanism. The plate has 5 position marks  
for repeatable positions (See fig. 13).  
Figure 9  
6
565DG/565TG Ortho-Biotic Preferred Care® Recliners Operating Instructions  
Download from Www.Somanuals.com. All Manuals Search And Download.  
565G UPHOLSTERY REMOVAL AND  
REPLACEMENT  
BACK CUSHION  
To remove: Release the two elastic straps which  
hold the button of the cushion to the back frame  
with small wire clips (See fig. 10).  
Grip top of cushion near back frame handgrips  
and slide up and off.  
Figure 10  
To replace: Reverse procedure.  
SEAT-LEG CUSHION  
Frame  
Key Ring  
To remove: Release the two elastic straps which  
hold the cushion to the back frame with small  
wire rings (See fig. 11).  
Adjust the chair into the semi-recline position.  
Strap  
Flip the seat cushion forward and release the  
two hooks which hold the cushion to legrest  
frame (See fig. 12).  
Hook  
Figure 11  
Slide the cushion downward and forward.  
To replace: Reverse procedure.  
ARM PANELS  
To remove: Grip the steel rod at the bottom of  
the side panel, located near the front of the side  
frame. Gently slide the rod backward. Flex the  
rod slightly until it disengages (See fig. 12).  
Detach the four screws from under the side  
frame arm plate.  
To replace: Reverse procedure.  
Figure 12  
565DG/565TG Ortho-Biotic Preferred Care® Recliners Operating Instructions  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
RECLINER POSITIONING MECHANISM  
TROUBLE-SHOOTING  
ADJUSTMENT INSTRUCTIONS FOR POSITION  
MECHANISM  
NOTE:Never lubricate the position  
mechanism assembly.  
Clevis ring and  
wire ring  
1. Turn the position adjustment handle down to  
the release position, and remove clevis pin  
and wire ring from top of assembly.  
(See fig. 13).  
Slide  
2. Slide positioning plate up, and turn square  
washer clockwise until snug (See fig. 13).  
Positioning plate  
3. Slide the positioning plate down over square  
washer. Replace clevis pin and wire ring.  
4. The position mechanism's handle should  
engage at about the halt way point. If more  
tension is desired, repeat the above procedure.  
Square washer  
Figure 13  
8
565DG/565TG Ortho-Biotic Preferred Care® Recliners Operating Instructions  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TILT-IN-SPACE GAS SPRING TROUBLESHOOTING  
PROBLEM:  
If the chair actuates without squeezing the release  
lever, the cable assembly needs to be adjusted.  
Bracket Assembly  
Cable  
Gas Spring Cylinder  
CORRECTION:  
1. Lean the chair on its side and remove clevis  
pin and wire rue ring that secure the top of  
the gas spring to the frame. Do not remove  
the cable.  
In  
Out  
2. Loosen the nut above the gas spring bracket.  
Rotate the gas spring out of the bracket  
(counterclockwise) 1/2 turn. Retighten nut on  
bracket, and reassemble the gas spring back  
to the frame. Check that cable is snapped into  
bracket (See fig. 14).  
Nut  
Rue Ring  
Figure 14  
Clevis Pin  
3. Test the operation of chair. If the chair still  
actuates without squeezing release lever,  
repeat the above procedure.  
PROBLEM:  
If the chair does not actuate with a person in the  
chair while squeezing the release lever and  
pushing on the back, then the cable is too loose  
and the assembly needs to be adjusted.  
Engage as shown  
CORRECTION:  
1. Ensure the cable is properly engaged onto the  
bracket assembly. If cable is not engaged on  
bracket, engage as shown in figure 15.  
2. With a person in the chair, recheck cable.  
If problem persists, go to step 3.  
Cable  
3. Lean the chair on its side and remove clevis  
pin and wire ring that secure the top of the gas  
spring to the frame. Do not remove the cable.  
Bracket Assembly  
4. Loosen the nut above the gas spring bracket.  
Rotate the gas spring into the bracket  
(clockwise) 1/2 turn. Retighten nut on bracket  
and reassemble the gas spring back to the  
frame (See fig. 14).  
Figure 15  
5. Test the operation of chair. If the chair does  
not actuate with a person in the chair while  
squeezing the release lever, repeat steps 3-5.  
565DG/565TG Ortho-Biotic Preferred Care® Recliners Operating Instructions  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
Release Lever  
Under Cusion  
CORRECT TILT POSITIONING  
FOR TILT-IN-SPACE  
NOTE:The Tilt chair is attendant operated only.  
For chair to operate properly, a person  
must be in the chair.  
Push Handle  
To tilt the chair back:  
1. Stand behind the chair, and locate the release  
lever under the push handle.  
2. Squeeze the lever while pushing down on the  
back. Once the desired position is attained,  
release the lever to lock into position  
(See fig. 16).  
Up Position  
To bring the chair up:  
1. Stand behind the chair, and locate the release  
lever under the push handle.  
2. Squeeze the release lever and lift the back up.  
Once the desired position is attained, release  
the lever to lock into position (See fig. 16).  
LEGREST OPERATION  
FOR TILT-IN-SPACE  
To lift legrest:  
Step on the front of the foot pedal, located on the  
side of the chair, until it locks in place (See fig. 16).  
Legrest Down  
To lower legrest:  
Step on the back of the foot pedal.  
Legrest Up  
Note: The legrest is easier to operate when the  
chair is in its fully tilted position, however  
legrest will operate in any position of tilt.  
Figure 16  
10  
565DG/565TG Ortho-Biotic Preferred Care® Recliners Operating Instructions  
Download from Www.Somanuals.com. All Manuals Search And Download.  
U.S.A., Corporate Headquarters:  
Graham-Field Health Products  
2935 Northeast Parkway  
Atlanta, Georgia 30360  
telephone: 800-347-5678, 770-447-1609  
fax: 800-726-0601, 678-291-3232  
Download from Www.Somanuals.com. All Manuals Search And Download.  

La Crosse Technology Thermometer WT 62U User Manual
La Crosse Technology Weather Radio CA85169 User Manual
Loewe Flat Panel Television R 37 Full HD+ 100 R 37 HD+ 100 User Manual
Lucent Technologies Server Release 82 User Manual
Magic Chef Microwave Oven MCD775RW1 User Manual
Magnavox Flat Panel Television 40ME314V User Manual
Makita Drill 8414D User Manual
Marantz Computer Monitor PD4292D User Manual
M Audio Speaker BX5as User Manual
Metra Electronics Automobile Accessories 99 8152 User Manual