Pub. 988-0154-452
EP-70R Speed
Electronic Speed Sensor
Installation Instructions
This document shows how to install an EP-70R speed sensor and how
to connect it to a NMEA 2000® network.
NMEA 2000 is the communication bus standard developed by the
National Marine Electronics Association (NMEA) for use in boats.
Lowrance has introduced a line of products that can communicate over
a NMEA 2000 network (LowranceNet).
All Lowrance NMEA 2000 capable devices are either NMEA 2000
certified or certification is pending.
CAUTION:
Installing LowranceNET NMEA 2000 devices is significantly
different from installing earlier Lowrance components without
NMEA 2000 features. You should read all of the installation
instructions before proceeding. Decide where you want to install
all components before drilling any holes in your vessel.
Some sonar or GPS display units may require a software upgrade to
display NMEA 2000 data correctly. For free software upgrades or
additional information on the LowranceNet NMEA 2000® network
Red NMEA 2000
connector
Smart module
Paddle wheel
speed module
The EP-70R speed sensor.
1
Download from Www.Somanuals.com. All Manuals Search And Download.
For complete instructions on setting up a new NMEA 2000 network or
expanding an existing one, see the NMEA 2000 document packed with
your EP-70R, "Setup and Installation of NMEA 2000 Networks, General
Information," part number 988-0154-173. If that document is missing,
it can be downloaded free from the Lowrance web site.
Recommended tools for this job include: drill, 7/8" (22 mm) drill bit, 1/8" (3
mm) drill bit for pilot holes, screwdriver. Required supplies for this job
include: four #8 stainless steel wood screws (3/4" long), high quality,
marine grade above- or below-waterline caulking compound.
Other supplies are not included, unless otherwise indicated. If you
want to feed the speed module cable through a transom or bulkhead,
use a 3/4" (19 mm) bit. A screwdriver is needed for mounting the speed
sensor.
Installation
To install the speed sensor, first find a location on the boat's transom
where the water flow is smoothest. Don't mount the sensor behind strakes
or ribs. These will disturb the water flow to the speed sensor. Make sure
the sensor will remain in the water when the boat is on plane. Also make
sure the location doesn't interfere with the boat's trailer. Typically, the
sensor is mounted about one foot to the side of the transom's centerline.
good location
Transom showing mounting location.
Once you've determined the proper location for the unit, place the
sensor on the transom. The bottom of the bracket should be flush with
the hull's bottom. Using the sensor as a template, mark the hull for the
screws' pilot holes. Drill four 1/8" holes, (3 mm) one in each end of the
slots. Mount the sensor to the hull using #8 stainless steel wood screws
(not included). Use a high quality, marine grade above- or below-
waterline sealant to seal the screws. Make sure the sensor is flush with
the bottom of the hull and tighten the screws.
3
Download from Www.Somanuals.com. All Manuals Search And Download.
Rear view
Bottom of hull
Speed sensor rear view.
Transom
Side view
Bottom of hull
Speed sensor side view.
If the base of the transom has a radius, fill the gap between the
transom and the sensor with sealant. This will help ensure a smooth
water flow.
Route the sensor's cable through or over the transom to the
LowranceNET. If you need to drill a hole in the transom to pass the
connector through, the required hole size is 7/8".
Caution:
If you drill a hole in the transom for the cable, make sure it is
located above the waterline. After installation, be sure to seal the
cable hole with the same marine grade above-or below-waterline
sealant used for the screws.
The EP-70R is now ready for use. Connect the sensor's red cable
connector to a T connector on the network backbone and plug it in.
If you have any questions concerning the installation of the EP-70R,
please contact your local boat dealer.
Connecting to a NMEA 2000 Network
A NMEA 2000 network is a communications link between two or more
devices that transfer NMEA 2000 information. LowranceNET is the
NMEA 2000 networking system developed by Lowrance Electronics. A
NMEA 2000 network functions like the phone wiring in a house. If, for
example, you pick up a phone in the living room you will be able to
hear the conversation someone is having on a phone in the bedroom.
4
Download from Www.Somanuals.com. All Manuals Search And Download.
In similar fashion, a NMEA 2000 network allows multiple display units
to receive data from a GPS antenna or multiple sonar units to receive
messages sent by a temperature sensor. A NMEA 2000 network gives
you the flexibility to view information like engine diagnostics and fuel
level data on digital gauges or display units located anywhere on your
boat.
There are two types of LowranceNet red connectors: the single T
connector (left) and the double T connector (right).
Network Backbone and Network Nodes
A network bus backbone consists of network cabling, terminators and T
connectors. Network nodes are made by fitting T-shaped connectors into
the backbone (using the sockets on the sides) and attaching any network
device to the bottom of the T.
Staying with the previous phone wiring example, T connectors on the
backbone are the equivalent of phone jacks spread throughout a house.
To pick up a phone and be able to hear a conversation from another
phone in the house, both phones have to be connected to the main phone
line. In similar fashion, only sensors and display units plugged into the
NMEA network can share information. The network backbone is like the
phone wiring that runs throughout a home.
It connects the network nodes, allowing them to communicate across the
network. Connections found in the middle of the bus could have T
connectors or backbone network cable plugged into one or both sides.
Connections at the end of a network will have the backbone cable plugged
into one side and a terminator plugged into the other, as shown in the
following figure.
5
Download from Www.Somanuals.com. All Manuals Search And Download.
Backbone cable
(to rest of bus)
Terminator at
the end of the
backbone (bus)
Double T
connector
Cable from
sensor or
display unit
Cap for unused
connector
NMEA 2000 network node located at the end of a NMEA 2000 backbone.
NOTE:
If you have a double T Connector on your network that is not
attached to a device, you must cap the unused connector with a
NMEA 2000 cap. This will protect the pin connectors from
corrosion. The NMEA 2000 cap looks like a terminator, but has
"Cap" stamped into the connector housing.
All T connectors on your network probably will be connected to a device.
If you want to add another node to a working network, add another T
connector. T connectors may be purchased from LEI (ordering
information appears on the back page of this booklet). If you are adding a
Lowrance or LEI NMEA 2000 sensor, it will come with a T connector.
Adding a Network Node
You can add a node to any existing connection, anywhere along the
network backbone. This connection could be between a T connector and a
terminator, between two T connectors, between a T connector and a
backbone extension cable or between two extension cables. Wherever you
want to add the new node, separate the sockets of the existing connection
and install the T connector between them.
If you want to add a node at the end of the backbone (network bus)
remove the terminator from the last connector, like the figure above.
Install the new T connector and attach the terminator to the side of the
connector.
6
Download from Www.Somanuals.com. All Manuals Search And Download.
Use T-connector or double T connector to add
device to bus (maintaining linear architecture)
Backbone cable
to rest of bus
Existing network
node
Attach
terminator at
end of bus
Devices connect to
double T connector
In this example, a new device is added to the NMEA 2000 bus by
installing a T connector between a T connector and a terminator at the
end of the backbone (network bus).
Additional Network Information
For more information on creating or expanding a network refer to the
NMEA 2000 network setup booklet, part number 988-0154-173, which
came packed with this document.
Configuration
The EP-70R Speed Sensor is not a configurable device. When selected
from a display unit, LMF-200 or LMF-400 device list, a message will
appear telling you if the sensor is working properly.
Displaying EP-70R Data
You can display EP-70R Speed Sensor data on the LMF-200 and LMF-
400 multi-function gauges and on NMEA 2000 compatible sonar and
GPS display units.
LMF-200
Speed sensor data can be shown on the Gauge, Single Digital, Dual
Digital and Fuel Manager pages.
Page Screen Rotation
The Page Screen Rotation consists of multiple pages that have been set
up for display. Once pages have been added to the page screen rotation,
they can be set to scroll across the screen automatically or manually.
Press the UP and DOWN keys to manually scroll pages across the
screen. Pressing the UP key moves the scroll in one direction. Pushing
the DOWN key moves the scroll in the other direction. You can use the
7
Download from Www.Somanuals.com. All Manuals Search And Download.
Autoscroll feature if you want the pages to automatically scroll across
the screen. Refer to your LMF -200 manual for more information about
Autoscroll.
Adding a page:
1. Press MENU, use the UP and DOWN keys to select PAGES and press
MENU, which will open the Pages menu with the following options: Add
Page, Rem Page, Autoscroll and Set Pop-up.
2. Select ADD PAGE and press MENU.
3. Select (Gauge, Single Digital, Dual Digital or Fuel Manager page)
and press MENU. You will be taken back to the main display, where the
page you selected will be shown.
Customizing Pages
The customizing pages feature allows you to choose what data will be
displayed and how it will be displayed on select pages. You can
customize the Gauge, Single Digital, Dual Digital and Fuel Manager
pages to display EP-70R Speed Sensor data.
To customize Gauge page:
1. After the Gauge page has been added to the page screen rotation, use
the UP and DOWN keys to display it on the screen.
2. Press MENU, select CUSTOMIZE and press MENU.
3. Highlight WATER SPEED and press MENU.
To customize Single Digital page:
1. After the Single Digital page has been added to the page screen
rotation, use the UP and DOWN keys to display it on the screen.
2. Press MENU, select CUSTOMIZE and press MENU.
3. Highlight WATER SPEED and press MENU.
To customize Dual Digital page:
1. After the Dual Digital page has been added to the page screen
rotation, use the UP and DOWN keys to display it on the screen.
2. Press MENU, select CUSTOMIZE and press MENU. The Position menu will
appear with two options: Top Data and Bottom Data.
3. Select the desired data position and press MENU.
4. Highlight WATER SPEED and press MENU.
8
Download from Www.Somanuals.com. All Manuals Search And Download.
To customize Fuel Manager page:
1. After the Fuel Manager page has been added to the page screen
rotation, use the UP and DOWN keys to display it on the screen.
2. Press MENU, select CUSTOMIZE and press MENU.
3. Highlight WATER SPEED and press MENU.
LMF-400
Speed sensor data can be shown on the Single Analog, Dual Analog,
Quad Analog, Single Digital, Dual Digital, Quad Digital and Fuel
Manager pages.
Page Screen Rotation
The Page Screen Rotation consists of multiple pages that have been set
up for display. Once pages have been added to the page screen rotation,
they can be set to scroll across the screen automatically or manually.
Use the ENTER and EXIT keys to manually scroll pages across the
screen. Pressing the ENTER key moves the scroll in one direction.
Pushing the EXIT key moves the scroll in the other direction. You will
use the Page Scrolling if you want pages to automatically scroll across
the screen. Refer to your LMF-400 manual for more information about
Page Scrolling.
To add a page to the display:
1. Press MENU, use the UP and DOWN keys to select PAGES and press
ENTER. A menu will pop up with four options: Add Page, Remove Page,
Page Scrolling and Pop-Ups Setup.
2. Select ADD PAGE and press ENTER.
3. Highlight (Single Analog, Dual Analog, Quad Analog, Single Digital,
Dual Digital, Quad Digital or Fuel Manager page) and press ENTER.
The following message will appear: Press Enter to add the selected page.
4. Press ENTER, which will take you back to the main display, where
the page you selected will be shown on the screen.
Customizing Pages
The customizing pages feature allows you to choose what data will be
displayed and how it will be displayed on selected pages. You can
customize the Single Analog, Dual Analog, Quad Analog, Single
Digital, Dual Digital, Quad Digital and Fuel Manager pages with speed
sensor data.
9
Download from Www.Somanuals.com. All Manuals Search And Download.
To customize Single Analog page:
1. Make sure the Single Analog page has been added to the page screen
rotation.
2. Use the ENTER and EXIT keys to scroll the Single Analog page onto
the main display.
3. Press MENU, use the UP and DOWN keys to select CUSTOMIZE and press
ENTER. The data menu will appear.
4. Select WATER SPEED and press ENTER.
To customize Dual Analog page:
1. Make sure the Dual Analog page has been added to the page screen
rotation.
2. Use the ENTER and EXIT keys to scroll the Dual Analog page onto the
main display.
3. Press MENU, use the UP and DOWN keys to select CUSTOMIZE and press
ENTER. The Position menu will appear with two options: Top Gauge
and Bottom Gauge.
4. Select the desired position and press ENTER. The data menu will
appear.
5. Highlight WATER SPEED and press ENTER.
6. You will be directed to the Position menu. Repeat steps 4-5 to
customize the other position or press EXIT twice to return to the main
display.
To customize Quad Analog page:
1. Make sure the Quad Analog page has been added to the page screen
rotation.
2. Use the ENTER and EXIT keys to scroll the Quad Analog page onto the
main display.
3. Press MENU, select CUSTOMIZE and press ENTER. The Position menu
will appear with four options: Top Left, Top Right, Bottom Left and
Bottom Right.
4. Select the desired position and press ENTER. The data menu will
appear.
5. Highlight WATER SPEED and press ENTER.
6. You will be directed to the Position menu. Repeat steps 4-5 to
customize the other positions or press EXIT twice to return to the main
display.
10
Download from Www.Somanuals.com. All Manuals Search And Download.
To customize Single Digital page:
1. After the Single Digital page has been added to the page screen
rotation, use the ENTER and EXIT keys to display it on the main screen.
2. Press MENU, use the UP and DOWN keys to select CUSTOMIZE and press
ENTER. The data menu will appear.
3. Highlight WATER SPEED and press ENTER.
To customize Dual Digital page:
1. After the Dual Digital page has been added to the page screen
rotation, use the ENTER and EXIT keys to display it on the main screen.
2. Press MENU, use the UP and DOWN keys to select CUSTOMIZE and press
ENTER. The Position menu will appear with two options: Top Data and
Bottom Data.
3. Highlight the desired data position and press ENTER.
4. Select WATER SPEED and press ENTER.
5. You will be taken back to the Position menu. To display data in the
other data box, repeat Steps 3-5.
6. Press EXIT twice to return to the main display.
To customize Quad Digital page:
1. After the Quad Digital page has been added to the page screen
rotation, use the ENTER and EXIT keys to display it on the main screen.
2. Press MENU, use the UP and DOWN keys to select CUSTOMIZE and press
ENTER. The Position menu will appear with four options: Data Box 1,
Data Box 2, Data Box 3 and Data Box 4.
3. Highlight the desired data position and press ENTER.
4. Select WATER SPEED and press ENTER.
5. You will be taken back to the Position menu. To display data in
another data box, repeat Steps 3-5.
6. Press EXIT twice to return to the main display.
To customize Fuel Manager page:
1. After the Fuel Manager page has been added to the page screen
rotation, use the ENTER and EXIT keys to display it on the main screen.
2. Press MENU, use the UP and DOWN keys to select CUSTOMIZE and press
ENTER. The Position menu will appear with three options: Top Data,
Center Data and Bottom Data.
3. Highlight the desired data position and press ENTER.
4. Select WATER SPEED and press ENTER.
11
Download from Www.Somanuals.com. All Manuals Search And Download.
5. You will be taken back to the Position menu. To display data in
another data box, repeat Steps 3-5.
6. Press EXIT twice to return to the main display.
Display Unit
The Overlay Data function will be used to show speed sensor data on
your display unit.
To add speed sensor as overlay data:
1. Press MENU, highlight OVERLAY DATA and press ENTER.
2. Select (PRESS ENT TO ADD…) and press ENTER.
3. Highlight NMEA 2000 and press ENTER. A list of devices on the
network will appear.
4. Select EP-70R: SPEED and press ENTER.
5. The following checkboxes will appear: Water Distance and Water
Speed. Highlight the desired data and press ENTER, which will place a
checkmark in its enabled box. It now will be shown as overlay data on
your display unit's screen.
6. Repeat step 5 to display the other data category, or press EXIT
repeatedly to return to the main display.
Device Name
You can change how your speed sensor will be displayed on your unit's
NMEA 2000 Devices list by inputting a customized device name in the
Device Name dialog box.
NOTE:
Changing the Device Name only will affect the way the EP-70R is
shown on your display unit. The customized device name will not
be seen by other devices or display units on the NMEA 2000
network.
To input a Device Name:
1. Press MENU twice, select NMEA 2000 or NETWORKING and press ENTER. A
menu will appear with five options: Bus Setup, Fuel Management,
NMEA
2000
Alarms,
Waypoint
Sharing
and
Backlight
Synchronization.
2. Highlight BUS SETUP and press ENTER, which will open the Bus
Configuration menu. A list of network devices will be at the top of the
page.
3. Select the desired speed sensor and press ENTER. The Device
Configuration menu will appear with the Device Name dialog box
highlighted.
12
Download from Www.Somanuals.com. All Manuals Search And Download.
4. Press ENTER. Use the arrow keys to input the desired name for the
speed sensor and press ENTER. Press EXIT repeatedly to return to the
main display.
To reset device name to default setting:
1. Press MENU twice, select NMEA 2000 or NETWORKING and press ENTER. A
menu will appear with five options: Bus Setup, Fuel Management,
NMEA
2000
Alarms,
Waypoint
Sharing
and
Backlight
Synchronization.
2. Highlight BUS SETUP and press ENTER, to open the Bus Configuration
menu. A list of network devices will be at the top of the page.
3. Select the desired speed sensor and press ENTER. The Device
Configuration menu will appear with the Device Name dialog box
highlighted.
4. Press ENTER. Depress the left arrow key until the device name
disappears. Press ENTER, then press EXIT to return to the NMEA 2000
menu.
5. Highlight the device and press ENTER. The Device Configuration
menu will open. The device name will be reset to its default setting.
Press EXIT repeatedly to return to the main display.
Restore Defaults
Located on the Advanced Options menu, the Restore Defaults
command allows you to reset an EP-70R Speed Sensor's settings to
factory defaults.
To restore default settings:
1. Press MENU twice, select NMEA 2000 or NETWORKING and press ENTER. A
menu will appear with five options: Bus Setup, Fuel Management,
NMEA
2000
Alarms,
Waypoint
Sharing
and
Backlight
Synchronization.
2. Highlight BUS SETUP and press ENTER, which will open the Bus
Configuration menu. A list of network devices will be at the top of the
page.
3. Select EP-70R Speed and press ENTER. The Device Configuration
menu will appear.
4. Highlight ADVANCED OPTIONS and press ENTER.
5. Select RESTORE DEFAULTS and press ENTER. The following message will
appear: Are you sure you wish to change this device's configuration?
6. Highlight YES and press ENTER. Press EXIT repeatedly to return to
the main display.
13
Download from Www.Somanuals.com. All Manuals Search And Download.
Notes
14
Download from Www.Somanuals.com. All Manuals Search And Download.
LOWRANCE ELECTRONICS
FULL ONE-YEAR WARRANTY
"We," "our," or "us" refers to LOWRANCE ELECTRONICS, INC., the manufacturer of
this product. "You" or "your" refers to the first person who purchases this product as a
consumer item for personal, family or household use.
We warrant this product against defects or malfunctions in materials and workmanship,
and against failure to conform to this product's written specifications, all for one (1) year
from the date of original purchase by you. WE MAKE NO OTHER EXPRESS
WARRANTY OR REPRESENTATION OF ANY KIND WHATSOEVER CONCERNING
THIS PRODUCT. Your remedies under this warranty will be available so long as you can
show in
a
reasonable manner that any defect or malfunction in materials or
workmanship, or any non-conformity with the product's written specifications, occurred
within one year from the date of your original purchase, which must be substantiated by
a dated sales receipt or sales slip. Any such defect, malfunction, or non-conformity which
occurs within one year from your original purchase date will either be repaired without
charge or be replaced with a new product identical or reasonably equivalent to this
product, at our option, within a reasonable time after our receipt of the product. If such
defect, malfunction, or non-conformity remains after a reasonable number of attempts to
repair by us, you may elect to obtain without charge a replacement of the product or a
refund for the product. THIS REPAIR, OR REPLACEMENT OR REFUND (AS JUST
DESCRIBED) IS THE EXCLUSIVE REMEDY AVAILABLE TO YOU AGAINST US FOR
ANY DEFECT, MALFUNCTION, OR NON-CONFORMITY CONCERNING THE
PRODUCT OR FOR ANY LOSS OR DAMAGE RESULTING FROM ANY OTHER
CAUSE WHATSOEVER. WE WILL NOT UNDER ANY CIRCUMSTANCES BE LIABLE
TO ANYONE FOR ANY SPECIAL, CONSEQUENTIAL, INCIDENTAL, OR OTHER
INDIRECT DAMAGE OF ANY KIND.
Some states do not allow the exclusion or limitation of incidental or consequential
damages, so the above limitations or exclusions may not apply to you.
This warranty does NOT apply in the following circumstances: (1) when the product has
been serviced or repaired by anyone other than us; (2) when the product has been
connected, installed, combined, altered, adjusted, or handled in a manner other than
according to the instructions furnished with the product; (3) when any serial number has
been effaced, altered, or removed; or (4) when any defect, problem, loss, or damage has
resulted from any accident, misuse, negligence, or carelessness, or from any failure to
provide reasonable and necessary maintenance in accordance with the instructions of the
owner's manual for the product.
We reserve the right to make changes or improvements in our products from time to time
without incurring the obligation to install such improvements or changes on equipment or
items previously manufactured.
This warranty gives you specific legal rights and you may also have other rights which
may vary from state to state.
REMINDER: You must retain the sales slip or sales receipt proving the date of your
original purchase in case warranty service is ever required.
LOWRANCE ELECTRONICS
12000 E. SKELLY DRIVE, TULSA, OK 74128
(800) 324-1356
15
Download from Www.Somanuals.com. All Manuals Search And Download.
How to Obtain Service…
…in the USA:
Contact the Factory Customer Service Department. Call toll-free:
For Lowrance: 800-324-1356. For Eagle: 800-324-1354
8 a.m. to 5 p.m. Central Standard Time, M-F
Lowrance Electronics and Eagle Electronics may find it necessary to change or end
their shipping policies, regulations and special offers at any time. They reserve the
right to do so without notice.
…in Canada:
Contact the Factory Customer Service Department. Call toll-free:
800-661-3983
905-629-1614 (not toll-free)
8 a.m. to 5 p.m. Eastern Standard Time, M-F
…outside Canada and the USA:
Contact the dealer in the country where you purchased your unit. To locate a
dealer near you, see the instructions in paragraph number 1 below.
Accessory Ordering Information
LEI Extras™, Inc. is the accessory source for sonar and GPS products
manufactured by Lowrance Electronics and Eagle Electronics. To order
Lowrance or Eagle accessories, please contact:
1) Your local marine dealer or consumer electronics store. To locate a Lowrance
the Dealer Locator. Or, consult your telephone directory for listings.
2) U.S. customers: LEI Extras Inc., PO Box 129, Catoosa, OK 74015-0129
Call toll free in the U.S., 800-324-0045, 8 a.m. to 5 p.m. Central
3) Canadian customers: Lowrance/Eagle Canada, 919 Matheson Blvd. E.
Mississauga, Ontario L4W2R7 or fax 905-629-3118.
Call toll free in Canada, 800-661-3983, or dial 905 629-1614 (not toll free), 8
a.m. to 5 p.m. Eastern Standard Time, M-F.
For Lowrance® and Eagle® Products
Pub. 988-0154-452
© Copyright 2007
All Rights Reserved
Printed in USA 082807
Lowrance Electronics, Inc.
16
Download from Www.Somanuals.com. All Manuals Search And Download.
|