Listen Stationary IR System  
There are three main components involry IR system:  
adiator(s)/Emitter(s)  
Receiver(s)  
he radiator transforms the RF audio signal from the LT-82  
ansmitters into an IR signal. This is essentially a  
The IR light from the radiators is detected by  
ten  
is an  
track of  
ceiver  
iving  
eadlightthat illuminates the room with non-visible IR  
ght. The size and shape of the room will determine how  
any radiators or “headlightsyou’ll need to fill the room  
r adequate signal coverage. It’s powered by either the  
-82 transmitter or an LA-205 extension/replacement  
ower supply. Hardware for most types of mounting  
onfigurations, comes standard with each radiator, and  
e radiator is available in two colors; grey or white.  
Transmitter(s)  
The LT-82 Stationary IR Transmitter accepts audio  
from an audio mixing console or other sources. It then  
turns this audio signal into an RF signal and delivers it  
to an LA-140 radiator via coaxial cable. The LT-82 also  
provides DC power for up to two LA-140 radiators via  
standard CAT-5 cabling. For a single channel system  
(mono or stereo) use one LT-82. Add more channels  
(up to 4 total) by adding more LT-82 units.  
Highlights  
• Simple to specify, install, maintain, and use.  
• Secure – the signal will not leave the room.  
• Up to four simultaneous mono or stereo channels allows for expanded applications.  
• Uses higher modulation (2.3 to 3.8MHz) frequencies thereby decreasing the risk of  
light interference from fluorescent lights and other sources.  
• Installation is simple using CAT-5 cables for power distribution.  
• The radiator mounting hardware is included with each radiator.  
• Users will enjoy the simple but refined look and feel of both the stetho and  
lanyard receivers.  
• Advanced battery management ensures long battery life.  
• Uses standard AAA alkaline batteries or an optional rechargeable pack (LA-364).  
• Compatible with other manufacturers.  
Two cables connect the LT-82 Transmitter to the  
radiator(s). CAT-5 cable is used for power, and coaxial  
cable is used for the signal. When more than one  
radiator is needed, they can be daisy-chained using  
the same type of cable. One LT-82 can power up to two  
• Limited lifetime warranty (radiator – 3 years and accessories 90 days).  
2
radiators.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
The Listen LT-82 is the heart of the stationary IR listening  
system. It takes the desired audio signal and sends it via coaxial  
cable to one or more IR radiator(s) (LA-140). The LT-82 can be  
operated in mono or stereo on one of four different carriers;  
up to four LT-82 units may be connected to provide up to four  
mono or stereo carriers to the radiator(s). The LT-82 generates  
DC power to power up to two LA-140 radiators. Two LT-82 units  
can be rack mounted in one rack space using the universal rack  
mount kit (LA-326). The LT-82 is used for government  
compliance (such as ADA), assistive listening, language  
interpretation, live theatre, houses of worship, courtrooms,  
secure rooms, and auditory description.  
Highlights  
• Use up to four LT-82 units to create a 1 to 4  
(mono or stereo) channel system.  
• The LT-82 will power up to two LA-140 radiators.  
• Several audio input configurations to fit most  
installations.  
• Audio processing can be activated as desired.  
1
2
3
6
4
5
7
1 Audio Section The input level of inputs 1 and 2 are adjusted by the INPUT control and are indicated on  
the first two VU meters. Final transmit level is adjusted with the TRANSMIT LEVEL control. The CONTOUR  
control boosts or cuts audio above 5 kHz. The PROCESS indicator is illuminated when the internal audio  
processor is activated. The STEREO indicator is illuminated when the stereo encoder is activated. A test  
tone is available to aid in set up.  
2. Transmit Section Use the UP and DOWN buttons to select the transmission channel. The LCD  
conveniently shows the selected channel, radiation status (on or o), lock and programming status.  
3. Monitor Section You can listen to the transmitted audio using the monitor jack and volume control.  
4. RF Section RF is delivered to the radiators using the two RF OUTPUT BNC  
Key Specifications  
• Input voltage 100-240VAC, 47-63Hz.  
• System audio performance 63-15KHz  
frequency response, >60dB signal to  
noise ratio (SNR) and <2% total  
harmonic distortion (THD).  
connectors. If more than one channel is required, daisy chain multiple LT-82 units together.  
5. Power Section Connect the universal power supply (included) to the unit with the POWER INPUT RJ-45  
connector. The POWER OUTPUT connectors are used to power up to two LA-140 radiators.  
6. Audio Output Section The stereo, line level phono connectors provide an output  
consisting of a mix of inputs 1 and 2.  
7. Audio Input Section Connect your audio source to inputs 1 and/or 2. Input 1 accepts a mono 3-pin  
XLR or phone connector with balanced, selectable mic, phantom mic or line level audio. Input 2 accepts  
stereo phono connectors and is unbalanced with selectable input levels of -10 and +10dBu.  
Configurations  
• LT-82-01 North America  
• LT-82-02 Asia, UK  
• LT-82-03 Europe  
Accessories  
Accessories for the LT-82 can be found on the  
Stationary IR Accessories page 6.  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
LA-140 Stationary IR Radiator/Emitter  
The LA-140 IR radiator/emitter packs high infrared power in a  
small and attractive design, in your choice of grey or white  
colors. Designed for easy installation using standard  
Highlights  
• Architecturally friendly design with white or grey color options.  
• Simple to install using CAT-5 and coax cables.  
• Mounting hardware included makes every installation simple.  
• Double radiator mounting options for twice the power.  
• Delay compensation adjustments built in.  
components, the LA-140 is powered via CAT-5 cabling while  
the RF modulated carriers are delivered via standard coaxial  
cable. Mounting brackets are included for wall, ceiling, desk, mic  
stand, and tripod mounting. Power can be supplied by the LT-82  
transmitter or from a separate power supply (LA-205). Built-in  
delay compensation prevents signal cancellation (multi-path)  
problems and eliminates the piled-up cabling that is required  
with other systems. The LA-140 is used for government  
compliance (such as ADA), assistive listening, language  
interpretation, live theatre, houses of worship, courtrooms,  
secure rooms, and auditory description.  
• 25 feet (7.6 m) of CAT-5 and coaxial cable are included with  
the radiator.  
1
3
4
2
Key Specifications  
• 10,000 ft2 (929 m2) coverage (one  
channel) when used with Listen receivers  
(half coverage per radiator with two  
channels, quarter coverage with  
four channels).  
• CAT-5 and coaxial maximum cable length:  
1,000 ft (305 m).  
• One LT-82 Transmitter or one LA-205  
Power Supply can power up to two LA-140  
radiators.  
1. LED Indicators The three colored LEDs provide visual indication of power, connectivity,  
and the presence of a signal. These LEDs can be deactivated in light sensitive rooms.  
2. Mounting Hardware and Cable Installation is quick and easy with the included  
mounting hardware for wall, ceiling, desk (shown), mic stand or tripod. Listen also  
includes 25 feet (7.6 m) of CAT-5 and coaxial cables (including connectors).  
3. RF Section RF from the LT-82 or another radiator is accepted at the RF INPUT BNC. The  
RF OUTPUT jack feeds RF to additional LA-140 radiator(s). The delay compensation  
adjustment ensures that all RF signals are transmitted by the radiator at the same time,  
thereby eliminating receiver drop outs created when signals are out of phase. The  
TERMINATION switch terminates the coaxial cable on the last radiator in the daisy chain.  
4. Power Section The CAT-5 POWER INPUT connector accepts power from the LT-82  
transmitter, from an optional LA-205 power supply or from another LA-140 radiator. The  
POWER OUTPUT connector provides power for up to one additional radiator. The dip  
switches are for setting options.  
Configurations  
• LA-140-GY Grey  
• LA-140-WH White  
with LA-205-01 North America  
LA-205-02 Asia, UK  
LA-205-03 Europe  
Accessories  
Accessories for the LA-140 can be found  
on the Stationary IR Accessories page 6.  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
LR-42/44 Infrared Receivers  
Users will love the comfortable, easy to use Listen LR-42 and  
LR-44 Receivers that feature the ability to receive up to four  
channels in mono or stereo. They use standard AAA alkaline  
batteries for more than 30 hours of operation, or a NiMH  
rechargeable battery pack that delivers 15 hours of use per  
charge. The unit features auto shut-off after 30 minutes of  
no audio carrier, further extending battery life. The LR-42/44  
boasts high performance audio specs in a small package and is  
compatible with other manufacturersproducts. The LR-42/44  
is used for government compliance (such as ADA), assistive  
listening, language interpretation, live theatre, houses of  
worship, courtrooms, secure rooms, and auditory description.  
Highlights  
• Easy to use with outstanding audio performance.  
• Users have the option of either the LR-42 stetho receiver, or the  
LR-44 lanyard receiver which is compatible with a variety of  
earphones.  
• Auto-shut off extends battery life.  
• Outstanding battery life (up to 30 hours).  
• Uses standard AAA alkaline non-proprietary batteries, or  
rechargeable battery pack.  
• LA-350 and LA-351 charging/storage platforms make it simple  
and easy to charge batteries, store and distribute units.  
• Programmable options expand applications and simplify  
channel selection for users.  
2
3
1
4
Key Specifications  
• 30/15 hours battery life AAA  
alkaline/rechargeable batteries.  
• 63-15kHz frequency response,  
60dB SNR, <2% total  
harmonic distortion (THD).  
1. User Buttons Press the POWER button to turn the unit on or to check battery status after power  
up. The SEL button changes the channel.  
2. LED Indicators When the SEL is pressed the LED indicators indicate which of the four channels is  
Configurations  
• LR-42 IR Stethoscope 4-Channel Receiver  
• LR-44 IR Lanyard 4-Channel Receiver  
selected. If the POWER is pressed, the battery status is indicated.  
3. Volume Control The user adjusts this to set the volume on the earphones.  
4. Battery A removable battery compartment houses two AAA alkaline batteries, or a sealed NiMH  
rechargeable battery pack  
Accessories  
Accessories for the Listen Receivers can be  
found on the Stationary IR Accessories page 6.  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
Stationary IR Accessories and Systems  
Accessories  
Listen provides a variety of accessories to meet your Stationary IR needs. Choose from Connectors/Cables, Batteries/Power Supplies,  
Charging/Storage Cases, Earphones, Mounting Options, and Microphones all providing outstanding performance for crisp, clear sound.  
Mounting Options  
Power/ Storage Options  
Earphones  
LA-364  
LA-164  
• LA-152 IR Receiver Battery Compartment (Non-Charging)  
• LA-204 7.5 VDC Replacement Power Supply for Charging  
Systems  
• LA-205 30 VDC Extension/Replacement Power Supply for  
LA-140/LT-82  
• LA-363 High Capacity AAA Alkaline Batteries (2)  
• LA-364 NiMH Rechargeable Battery Pack for IR Receivers  
• LA-320 Configurable Carrying Case  
LA-342  
• LA-161 Single Ear Bud  
• LA-162 Stereo Ear Buds  
• LA-164 Earspeaker  
• LA-ounting Kit  
• LA-3r Floor Stand  
• LA-34ationary IR Dual Radiator  
Mounting Bracket  
• LA-165 Stereo Headphones  
• LA-166 Neck Loop  
• LA-170 Behind-the-Head  
Stereo Earphones  
• LA-350 8-Unit IR Charging/Storage Station  
• LA-351 8-Unit IR Storage Station  
Stationary IR Systems  
Listen’s Stationary IR Systems meet the needs of the novice to the advanced user, offering a range of options for both budget and  
applications. The Basic Sning requirements.  
The Performance Stationd the radiator.  
Use the Advanced Insta
LS-80  
Product Descriptio
LS-80  
1
LS-81  
LS-82  
LS-83  
LS-84  
LS-85  
LT-82 Stationary IR Transmitter  
1
1
2
4
1
1
2
8
4
2
2
1
1
5
1
1
1
3
1
1
1
4
LA-326 Universal Rack Mounting Kit  
LA-140 Stationary IR Radiator  
1
4
8
LR-42 IR Stethoscope 4-Channel Receiver  
LR-44 IR Lanyard 4-Channel Receiver  
LA-165 Stereo Headphones  
48  
LA-166 Neck Loop  
LA-363 High Capacity AAA Alkaline Batteries (2)  
LA-364 NiMH Rechargeable Battery Pack  
LA-350 8-Unit IR Charging/Storage Station  
LA-351 8-Unit IR Storage Station  
4
4
8
1
48  
6
5
1
1
1
LA-304 Assistive Listening Notification Signage Kit  
1
1
2
1
1
• For power cords add the following designators for selected region configuration:  
North America -01  
Asia, UK -02  
Europe-03  
• To designate white or grey colors for the radiators add designators -WH or -GY.  
Example:  
System Designator  
Color  
Each Stationary IR System delivers Listen’s commitment to  
providing you with a customizable solution that is simple to  
specify, install, and use. You will enjoy outstanding performance  
with exceptional support from the Listen team.  
Listen System  
LS-82-01-GY  
Don’t miss a single sound. Listen.  
Configuration  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
Listen Tec hnologies C orpora tion  
14912 Herita gec rest Wa y  
Bluffda le, Uta h 84065-4818, U.S.A.  
+1.801.233.8992  
North Americ a  
+1.800.330.0891  
+1.801.233.8995  
Fa x  
www.listentec h.c om  
info@listentec h.c om  
Listen Tec hnologies G mbH  
Ja sminstr. 16  
90522 Obera sba c h, G erma ny  
Tel  
+49 911 955159 0  
Fa x  
+49 911 955159 40  
www.listentec h.de  
info@listentec h.de  
Printed in the United Sta tes of Americ a  
© 2008 Listen Tec hnologies C orpora tion® All Rights Reserved 2008319  
Don’t miss a single sound.  
Download from Www.Somanuals.com. All Manuals Search And Download.  

La Crosse Technology Clock Radio WT 5721 User Manual
Lenovo Computer Monitor C92 User Manual
Lenovo Laptop E30 User Manual
Lowrance electronic Radar Detector LRA 1000 User Manual
Lucent Technologies Network Router 9076 User Manual
Manitowoc Ice Ice Maker K00129 User Manual
Manitowoc Ice Water System RF1200W User Manual
McCulloch Chainsaw 964830301 User Manual
McCulloch Snow Blower 96192004100 User Manual
Merco Savory Toaster RT 2T User Manual