Linear Utility Trailer 2500 2346 LP User Manual

Model 2500-2346-LP  
Operating Instructions  
Plug-in Vehicle Loop Detector  
Single Channel – Dual Solid State Outputs  
General/Overview:  
The Linear / Osco Model 2500-2346-LP operates on 12 VDC, 24 VDC, and 24 VAC, and is designed for low power requirements. The detector is  
designed to handle gate, parking, drive-through, and all access control applications where solid-state outputs are required for both the detect and  
“fail” outputs. From a diagnostic standpoint, the Model 2500-2346-LP automatically and continuously senses three (3) types of possible loop fault  
conditions: Open Loop(s), Shorted Loop(s), sudden changes in inductance exceeding 25% of the nominal inductance. The Model 2500-2346-LP also  
displays the frequency of the loop upon power up. Immediately after applying power, the unit displays 2 or 3 numbers quickly flashing (values  
between 13 and 150 kilohertz) before the DEFLECTOMETER resets to zero. This allows you to measure and separate the frequency of each  
detector loop. The detector frequency should be adjusted so that there is a minimum of 5 kilohertz of separation between all adjacent loops.  
The front panel DEFLECTOMETER display is active for 2 minutes following power-up or after any button press. This adds approximately 10 mA to  
the current draw.  
Setting Sensitivity:  
The DEFLECTOMETER (front panel 7-segment LED) aids in setting the detector to the most optimum sensitivity level to help  
ensure the detection of all vehicles, including motorcycles and high bed vehicles.  
For typical vehicles (mid-size vehicle / small pick up) utilizing properly installed roadway loops, when the number 4, 5, or 6  
(5 being optimum) is displayed on the DEFLECTOMETER during the DETECT output period then the sensitivity is set correctly.  
For high profile vehicles (commercial trucks, 4x4’s, etc), DEFLECTOMETER reading 3 or 4 will be best. For low profile vehicles  
(sports cars, etc), DEFLECTOMETER reading 6 or 7 will be best.  
Adjusting sensitivity utilizing the DEFLECTOMETER:  
The DEFLECTOMETER should read zero (0) with no vehicle over the roadway loop.  
If a mid-size vehicle, located over the roadway loop causes the number 7 to be displayed on the DEFLECTOMETER, you need  
to lower the sensitivity two levels (7 – 2 = DEFLECTOMETER reading 5). This can be done by pressing the front panel SENS  
(down) push button twice.  
If a mid-size vehicle, located over the roadway loop causes the number 2 to be displayed on the DEFLECTOMETER, you need  
to add three sensitivity levels (2 + 3 = DEFLECTOMETER reading 5. This can be done by pressing the front panel SENS(up)  
push button 3 times.  
Another great feature to note is that the sensitivity dynamically updates after each push button position change, allowing you to  
change sensitivity settings while a vehicle is over the loop zone.  
Adjusting sensitivity without using the DEFLECTOMETER (Manually set Sensitivity):  
The Model 2500-2346-LP offers 10 levels of sensitivity (0 to 9). This can be manually set to any desired level by pressing the  
SENSor SENSfront panel push buttons when a vehicle is NOT over the roadway loop. The sensitivity level will be displayed  
on the 7-segment LED. The factory default is level 4. Pressing the SENSor SENSswitch once will display the sensitivity  
without changing the setting. After pressing the SENSor SENSswitches to display the sensitivity, the sensitivity can be  
changed by pressing the SENSor SENSswitches again. The display will automatically return to the normal display after  
several seconds.  
Dip Switch Functions:  
Dip Switch 1 & 2 – Frequency: The operating frequency is controlled by the setting of switches 1 & 2 of the 8 position DIP Switch. Occasionally  
when loops are in close proximity to each other, it may be necessary to select different frequencies for each loop detector to avoid loop interference  
(crosstalk). The actual loop frequency is a function of the size of the loop, number of turns of loop wire in the loop, length of the lead-in cable, and the  
setting of the frequency switches. When power is applied to the detector, the operating frequency (between 13 and 150 kilohertz) is displayed on the  
front panel 7-segment LED (2 or 3 numbers will quickly flash before the DEFLECTOMETER goes to zero) allowing you to measure the frequency of  
each detector/loop. The detector frequency should be adjusted so that there is a minimum of 5 kilohertz of separation between all adjacent loops.  
Dip Switch 3 – Fail-Safe / Fail-Secure Operation: Either Fail-Safe or Fail-Secure Operation is controlled by the setting of switch 3 of the 8 position  
100909  
Linear /OSCO  
Page 1  
pn 888-1505-001  
19 Railroad Avenue, Casnovia, MI 49318  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Lenox Thermostat L5711U User Manual
LG Electronics Microwave Oven MC 805CLR User Manual
Liebert Refrigerator 1800 User Manual
Liebert Switch SmartSwitchTM User Manual
Lincoln Electric Welding Consumables NR 131 User Manual
Lowrance electronic SONAR X 55A User Manual
M Audio Computer Monitor SESSION User Manual
Meade Weather Radio TE653ELW M User Manual
Melissa Blood Pressure Monitor 630 016 User Manual
Middleby Marshall Oven PS310 User Manual