Linear Sander WO15Z 1 User Manual

WO15Z-1  
Receptacle, Series 300  
Radio Frequency Controlled, 120 VAC, 15A, Duplex  
GROUND  
GREEN  
TOTAL LOADS MUST NOT EXCEED  
15 AMPS @ 120 VAC  
(INCLUDES ALL LOADS PLUGGED INTO  
THE RECEPTACLE)  
ALWAYS POWERED  
OUTLET  
WHITE  
CONTROLLED  
OUTLET  
NEUTRAL  
BLACK  
LINE 120 VAC  
TOTAL LOADS MUST NOT EXCEED 15 AMPS @ 120 VAC (INCLUDES ALL LOADS PLUGGED  
INTO THE RECEPTACLE  
NOTE: This module must be “included in the Network” only where it will be permanently installed. The proper operation of this node in the  
mesh network is dependent on it knowing its location with respect to other nodes.You cannot “test bench” configure this module, then install.  
STEP 3. You should see an indication on your Controller that the  
“DEVICE WAS INCLUDED” in the network.  
WO15Z-1 DUPLEX RECEPTACLE  
Linear’s family of Z-Wave certified wireless lighting controls (switches,  
dimmers, outlets and plug-in modules) brings a new level of intelligent  
wireless capability to commercial and residential environments.  
NOTE: If you have trouble adding the WO15Z-1 to a group it may be  
that the Home ID and Node ID were not cleared from it after testing.  
You must first “RESET UNIT” with your controller to remove it from the  
network.  
The Z-Wave wireless protocol is an international wireless standard  
for remote home automation, security and other applications.  
Embedded in each device, the Z-Wave smart chip enables two-way RF  
communication among hundreds of Z-Wave enabled devices, allowing  
products and services from multiple manufacturers to work seamlessly.  
Although adding it to a group includes it in the network, removing it from  
a group does not remove it from the network. If removed from a group, it  
functions as a repeater only.RESET UNIT” removes it from the network  
Linear Z-Wave products are easy to install, and allow dealers to create  
an integrated wireless network with nearly limitless expansion and  
interoperability with security and health monitoring systems, energy  
management, home entertainment, appliances, and more.  
Receptacle Configuration  
TheWO15Z-1 Receptacle controls the ON and OFF of a load connected  
to the controlled outlet (See Wiring Diagram for identification).The  
other outlet remains powered all the time. A button on the face of the  
receptacle is used to add the module to the wireless network and be  
controlled from the wireless controller.With the Wireless Controller, the  
WO15Z-1 Receptacle can be turned ON and OFF remotely, and can  
be included in groups that operate at the same time (a group can be a  
single module), and in scenes that set a lighting mood.  
As part of a Z-Wave network, the WO15Z-1 will also act as a wireless  
repeater to insure that commands intended for another device in the  
network are received. This is useful when the device would otherwise  
be out of the radio range of the wireless controller.  
DANGER! SHOCK HAZARD. Read and understand these  
instructions before installing. This device is intended for installation in  
accordance with the National Electric code and local regulations in the  
United States, or the Canadian Electrical Code and local regulations  
in Canada. It is recommended that a qualified electrician perform this  
installation. Make sure the total load controlled does not exceed 1800  
watts. For indoor use only. Retain instructions for future use.  
Local ON and OFF  
When the button on the face of the WO15Z-1 is pressed, the power to  
the controlled outlet will turn on. When the button is pressed again, the  
controlled outlet will turn off.  
Child Protection  
The WO15Z-1 controlled outlet can be set in a child protect mode by the  
Wireless Controller. When this mode is active, a user will have to press  
the button on the face 3 times rapidly to activate the attached load. The  
module operates normally when controlled by the Wireless Controller.  
INSTALLATION  
Wire this receptacle in place of a current receptacle according to the  
diagram above. Use copper wire only, or equivalent.  
Other Functions  
INCLUDING WO15Z-1 TO THE NETWORK  
The button on the face of theWO15Z-1 Receptacle can be used to carry  
out inclusion (add to a group), association (operate simultaneously with  
other nodes), exclusion (remove from group) or reset (remove from  
network). The WO15Z-1 has a blue indicator LED. This LED will turn  
on when the controlled outlet is on and will turn off when the controlled  
outlet is off. However, its behavior can be configured as a “night light”  
(LED ON when the controlled outlet is off). See Configuration section  
below on how to do it.  
STEP 1. Prepare the Controller to include a unit to the network, by  
adding it to a group (method of adding a node to the network). Refer to  
controller instructions.  
STEP 2. The WO15Z-1 must be in its permanently installed  
location. Tap the button on the face of the WO15Z-1 once when your  
controller indicates (to include in the network).  
1
Download from Www.Somanuals.com. All Manuals Search And Download.  

KVH Industries Satellite TV System TracVision G4 User Manual
La Crosse Technology Clock Radio WT 2160 User Manual
La Crosse Technology Portable Radio WD 3210 User Manual
Lenovo Laptop E430 User Manual
LG Electronics Kitchen Entertainment Center L1717S User Manual
LST Smoke Alarm 5351E User Manual
Marmitek Home Security System DOORGUARD300TM User Manual
Marshall electronic Camera Lens V ZPL06 User Manual
Maytag Clothes Dryer MD7500 User Manual
Maytag Cooktop MGC5536BDW User Manual