1. PRODUCT DESCRIPTION
2. OPEN THE CASE
The Model AL-1 is a wireless personal alert receiver designed for use with existing
nurse call annunciation systems. In a typical installation, the receiver is used in the
place of, or in conjunction with, a standard pull cord to activate a corridor light, bed
light, room light, and any audible devices to indicate the need for assistance. Up to 32
wireless transmitters can be programmed to activate each receiver.
ALERT
RESET
AL-1
SERVICE
POWER
SQUEEZE THE CASE SIDES NEAR
THE TABS AND TILT UPWARD
Three indicators on the front of the receiver display the system status. The green
POWER indicator lights when power for the receiver is present. The yellow SERVICE
indicator lights if a transmitter has sent a low battery signal. The red ALERT indicator
lights when a transmitter has been triggered, showing that the receiver’s outputs have
been activated.
Pull Cord
Alert
Link
Pressing the RESET button on the top of the receiver for less than two seconds will
reset any transmitter low battery indications. Pressing the RESET button for more
than three seconds will clear the ALERT indication and reset the relay outputs if in
the latched mode.
The receiver contains four normally open 1-amp relay contacts that close when
activated. One relay provides an isolated output. The three other relays are isolated
when open and have a common return. The receiver relays can operate in “normal” or
“failsafe” mode. In normal mode, the relays will energize when the receiver is triggered.
In failsafe mode, the relays are energized continuously until the receiver is triggered.
Failsafe mode supervises the system by causing the outputs to activate if power is
removed from the receiver. Both modes provide normally open outputs.
Power for the receiver is supplied by a plug-in transformer. The receiver can be
mounted directly to a wall or to a single-gang electrical box with the hardware
supplied.
Installation Instructions
(760) 438-7000 • FAX (760) 438-7043
USA & Canada (800) 421-1587 & (800) 392-0123
Toll Free FAX (800) 468-1340
3. COMPONENT LOCATIONS
4. SET THE MODE
5. INSTALL THE MOUNTING PLATE
NORMAL MODE
RELAYS ACTIVATE DURING ALERT
RESET BUTTON
PRESS FOR 1 SECOND TO
RESET SERVICE INDICATOR;
PRESS AND HOLD FOR 3 SECONDS
TO RESET OUTPUTS
LATCH JUMPER
ALERT LIGHT
LIGHTS RED WHEN THE
OUTPUTS ARE ACTIVATED
ATTACH THE MOUNTING
LATCHES ALERT OUTPUTS
JUMPER OFF = MOMENTARY
JUMPER ON = LATCH
PLATE DIRECTLY TO THE WALL
WITH WOOD SCREWS AND
ANCHORS OR USE THE MACHINE
SCREWS TO ATTACH THE
MOUNTING PLATE TO A
SINGLE-GANG ELECTRICAL BOX
MODE JUMPER OFF OR ON ONE PIN
- AND -
BOTH MODE SWITCHES TO NORMAL
MODE JUMPER
SELECTS NORMAL OR
FAILSAFE MODE
SERVICE LIGHT
LIGHTS YELLOW WHEN
A TRANSMITTER HAS
SENT A LOW BATTERY
SIGNAL
JUMPER OFF = NORMAL
JUMPER ON = FAILSAFE
IMPORTANT!
THE MODE JUMPER MUST MATCH
THE MODE SWITCH SETTINGS
ALERT
RESET
SERVICE
POWER
STATUS LIGHT
FLASHES WHEN
RADIO SIGNALS
ARE RECEIVED;
LIGHTS WHEN
POWER LIGHT
LIGHTS GREEN WHEN
THE RECEIVER HAS
POWER
READY TO LEARN
OR ERASING
TRANSMITTERS;
BLINKS TO COUNT
THE NUMBER OF
TRANSMITTERS
WOOD
SCREWS
FRONT
FAILSAFE MODE
RELAYS ACTIVATE DURING ALERT
AND DURING POWER FALURE
LEARN BUTTON
PRESS TO ENTER LEARN MODE FOR
ENTERING TRANSMITTERS;
MACHINE
SCREWS
INSIDE
MODE SWITCHES
PRESS AND HOLD FOR 5 SECONDS TO
DISPLAY THE NUMBER OF TRANSMITTERS;
SETS THE OUTPUT MODE
MUST BE SET TO MATCH
THE MODE JUMPER
MODE JUMPER ON BOTH PINS
- AND -
BOTH MODE SWITCHES TO FAILSAFE
CONTINUE TO HOLD FOR 5 SECONDS AFTER
THE TRANSMITTER COUNT TO ERASE ALL TRANSMITTERS
6. CONNECT THE OUTPUTS
7. CONNECT THE TRANSFORMER
8. TRANSMITTER SETUP
LEARN BUTTON
CONNECT THE OUTPUTS TO
THE LOCAL CALL ANNUNCIATION
SYSTEM
ACTIVATING
TRANSMITTER
CONNECT THE RED AND BLACK
POWER INPUT WIRES TO THE
TRANSFORMER WIRES OR TO
THE SYSTEM'S AUXILIARY
POWER
AL-1 OUTPUT WIRE COLORS
SERVICE OUTPUT
MAXIMUM LOAD - 28 V @ 1 A
CONNECTIONS WILL VARY
DEPENDING ON THE
INSTALLATION
ORANGE
BROWN
WIRE NUTS ARE SUPPLIED
FOR MAKING CONNECTIONS
12-16 VOLT
SERVICE RELAY
LATCHES WHEN
ONE OR MORE
STORED TRANSMITTERS
INDICATE A LOW
BATTERY
AC/DC POWER
RED
BLACK
ALERT OUTPUTS
TO ADD A TRANSMITTER
PRESS AND RELEASE THE LEARN BUTTON,
STATUS INDICATOR WILL LIGHT (IF NOT, THE
MEMORY IS ALREADY FULL)
GRAY
WHITE
WHITE
VIOLET
YELLOW
GREEN
BLUE
STATUS LIGHT
ACTIVATE A TRANSMITTER, THE STATUS
INDICATOR WILL FLASH WHEN THE TRANSMITTER
IS ACCEPTED (UP TO 32 TRANSMITTERS ALLOWED)
CAUTION
POWER INPUT
MUST NOT
A MOMENTARY OR LATCHED
ALERT RELAY OUTPUT IS
SELECTED BY THE "LATCH"
JUMPER
ON PINS = LATCH
OFF PINS - MOMENTARY
TO CHECK THE TOTAL NUMBER
OF TRANSMITTERS IN MEMORY
PRESS AND HOLD THE LEARN BUTTON FOR ABOUT
5 SECONDS, THE STATUS INDICATOR WILL BLINK
ONCE FOR EACH TRANSMITTER IN MEMORY
EXCEED 16 VOLTS
CAUTION
TO ERASE ALL TRANSMITTERS
PLUG THE TRANSFORMER
INTO AN UN-SWITCHED
120 VAC OUTLET
CONTINUE TO HOLD THE LEARN BUTTON FOR ABOUT
10 SECONDS AFTER THE TRANSMITTER COUNT,THE
STATUS INDICATOR WILL BLINK ONCE WHEN THE
RECEIVER MEMORY IS ERASED
MAXIMUM CURRENT
FOR EACH RELAY
CONTACT IS 1 AMP
9. CLOSE AND SECURE THE CASE
10. SYSTEM TEST & OPERATION
IF IN THE LATCH MODE,
LINEAR LIMITED WARRANTY
This Linear product is warranted against defects in material and workmanship for twelve (12)
months. The Warranty Expiration Date is labeled on the product. This warranty extends only to
wholesale customers who buy direct from Linear or through Linear’s normal distribution channels.
Linear does not warrant this product to consumers. Consumers should inquire from their selling
dealer as to the nature of the dealer’s warranty, if any. There are no obligations or liabilities on the
part of Linear Corporation for consequential damages arising out of or in connection with use or
performance of this product or other indirect damages with respect to loss of property, revenue,
or profit, or cost of removal, installation, or reinstallation. All implied warranties, including implied
warranties for merchantability and implied warranties for fitness, are valid only until Warranty
Expiration Date as labeled on the product. This Linear Corporation Warranty is in lieu of all other
warranties express or implied.
TAB FITS
IN SLOT
ACTIVATE EACH TRANSMITTER
FROM VARIOUS LOCATIONS
PRESS THE RESET BUTTON
FOR AT LEAST 3 SECONDS
TO RESET THE OUTPUTS AND
TURN OFF THE ALERT INDICATOR
ALIGN TOP OF CASE INTO THE SLOT
MOMENTARILY PRESS THE
RESET BUTTON TO TURN
OFF THE SERVICE INDICATOR
(TRANSMITTER LOW BATTERY)
SQUEEZE THE CASE SIDES AND
SNAP THE COVER ONTO THE
MOUNTING PLATE
All products returned for warranty service require a Return Product Authorization Number (RPA#).
Contact Linear Technical Service at 1-800-421-1587 for an RPA# and other important details.
IMPORTANT !!!
ALERT
RESET
Linear radio controls provide a reliable communications link and fill an important need in portable
wireless signalling. However, there are some limitations which must be observed.
SERVICE
POWER
•
•
For U.S. installations only: The radios are required to comply with FCC Rules and Regulations
as Part 15 devices. As such, they have limited transmitter power and therefore limited range.
A receiver cannot respond to more than one transmitted signal at a time and may be blocked
by radio signals that occur on or near their operating frequencies, regardless of code settings.
Changes or modifications to the device may void FCC compliance.
POWER INDICATOR
SHOULD BE LIT
•
•
Infrequently used radio links should be tested regularly to protect against undetected
interference or fault.
ALERT INDICATOR
SHOULD LIGHT
WHEN THE TRANSMITTER
IS ACTIVATED
•
A general knowledge of radio and its vagaries should be gained prior to acting as a wholesale
distributor or dealer, and these facts should be communicated to the ultimate users.
SECURE THE CASE BY
INSERTING THE TWO SHORT
SCREWS INTO THE BOTTOM TABS
Copyright © 2002 Linear Corporation