Lindy Network Card 70918 User Manual

CardBus/PCMCIA  
2 Serial Ports  
User Manual  
English  
LINDY No. 70918  
© LINDY ELECTRONICS LIMITED & LINDY-ELEKTRONIK GMBH  
-
FIRST EDITION (JUNE 2004)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4.0 Pin Assignment  
5.0 Driver Installation  
Windows NT4.0  
1. Power up the system.  
2. After inserting the Serial Card Bus into PCMCIA Type II slot successfully,  
please follow the instructions as below:  
3. Please run the “Install_Serial.exe” program locate within folder of the  
attached driver CD :  
\PCMCIA\IO\CBS2000X\WinNT4\Install_Serial.exe  
4. When the installation application starts, click “Next” to continue,  
5. Ensure “Install” is selected, then click “Next”.  
6. Click “OK” to accept the license agreement.  
7. The system will install the driver and start it.  
The ports are immediately ready for using.  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
Windows 9x/2000/XP  
1. Power up the system.  
2. After inserting the Serial Card Bus into PCMCIA Type II slot successfully,  
please follow the instructions as below:  
3. System will show the “Found New Hardware Wizard” windows.  
a. You can select “Install the software automatically”.  
Let system searching and installing the appropriate driver automatically.  
b. You can select “Install from a list or specific location”.  
Please specify the driver locate within folder of the attached driver CD :  
\PCMCIA\IO\CBS2000X\  
4. System will search the “PCcard OX16CF950” driver and show the software  
installation warning windows. Select “Continue Anyway” to install driver.  
5. After installing driver successfully, please select “Finish” to complete the  
driver installation steps.  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
Note:  
5
The “Add New Hardware Wizard” windows will show up and re-install driver  
several times until you finish setting up each serial port.  
Please right click “My Computer”, select “Properties”, and “Hardware”, then  
Device Manager” to verify the driver installation completed.  
If there is any yellow exclamation mark on "PCcard OX16CF950", please  
remove this item from the Device Manager by clicking the Uninstall button  
and click Refresh to reinstall this driver again.  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
6.0 Configure COM Port  
1. Select the COM Port which you want to configure, for example COM4.  
Right check the mouse, and select the “Properties”.  
2. You can configure different operating settings through selecting the “High  
Speed Communications Port” properties pages.  
3. Please select “Settings” to configure standard Baud rate, Data bits, Parity,  
Stop bits and Flow control options, then select “Advanced Setting” to  
choose COM port number as picture shown.  
NOTE: RS-422/485 option is useless in this mode.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3. You can select “FIFOs” change the length of receiver and transmitter FIFO.  
This page is used to configure the FIFO trigger levels, i.e. at what fill levels the device will generate an  
interrupt, or apply automatic flow control. In addition, the FIFO can be completely disabled; although this is  
not recommended for normal operation. The four sliders allow adjustment of the various trigger levels in  
550 and 950 modes. These are described below:  
Transmitter FIFO interrupt trigger level - When the level of data in the transmit FIFO falls below this  
value, a transmitter interrupt is triggered. Setting this value to zero will not trigger an interrupt until the  
transmitter is completely idle.  
Receiver FIFO interrupt trigger level - When the level of data in the receiver FIFO reaches this  
value, a receiver data interrupt is triggered.  
Flow On flow-control limit - When the level of data in the receiver FIFO reaches this value as data  
is read from the FIFO, a handshake is triggered to instruct the remote transmitter that it is free to  
transmit data (E.g. Transmit an XON character to the remote machine).  
Flow Off flow-control limit - When the level of data in the receiver FIFO reaches this value as it fills  
up, a handshake is triggered to instruct the remote transmitter to stop sending data as the FIFO is  
becoming full. (E.g. Transmit an XOFF character to the remote machine).  
The FIFO trigger levels can be fine tuned to gain optimum performance, depending on system  
performance, baud rate used, levels of serial traffic etc.  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
4. You can select “Data Rate” change the crystal Frequency of input clock.  
This page provides a list of common crystal values used with COM ports. Select Detect crystal  
frequency” to detect the input clock frequency to the UART. (This requires that the port is not currently in  
use by another application).  
The baud rate can optionally be adjusted according to the data rate required. To enable the advanced  
baud rate configuration options, deselect the Use default baud rate” box. In normal operation, the driver  
will generate the desired baud rate from the crystal frequency. The quad speed option will multiply all  
application selected baud rates by 4 by utilising the OX16C95x Times clock register (TCR). The driver can  
multiply this baud rate, or divide it using the Clock Prescaler register (CPR).  
The clock pre-divisor is used to divide the input clock prior to baud rate generation. This means a high  
speed crystal (e.g. 50MHz) can be pre-divided to generate standard baud rates (In this case 50 / 27.125 =  
1.8433 MHz, which will emulate a 1.8432 MHz crystal with less than 0.01% bit rate error). Alternatively, the  
pre-divisor could be switched off to allow data rates up to 12.5Mbps to be generated.  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
This device complies with Part 15 of the FCC Rules.  
Operation is subject to the following two conditions:  
(1) this device may not cause harmful interference,  
and (2) this device must accept any interference  
received, including interference that may cause  
undesired operations.  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  

Land Pride Lawn Mower RCR26 Series User Manual
Learning Resources Games EI 8920 User Manual
Leica Binoculars 10x42 BRF User Manual
LL Bean Weather Radio 0FHC9 User Manual
Magnavox Portable CD Player MPC270 User Manual
Maytag Dishwasher 4912 User Manual
McIntosh Portable Speaker XCS1K User Manual
Mellerware Slow Cooker 2 7 5 6 03 2 0 W User Manual
Metrologic Instruments Scanner Hand Held Scanner User Manual
Midland Radio Two Way Radio LXT118 User Manual