Lightolier Indoor Furnishings 100IFIC User Manual

Instruction Sheet Number 1101FIC  
Page ꢀ of 2  
Installation Procedure for High Wattage Insulated Ceiling  
Frame-In Kits ꢀ00IFIC, ꢀꢀ0ꢀFIC, 200ꢀFIC  
Read and understand these instructions before installing fixture.  
This fixture is intended for installation in accordance with the National Electrical Code and local regulations. To assure full compliance with local codes and  
regulations, check with your local electrical inspector before installation. To prevent electrical shock, turn off electricity at fuse box before proceeding.  
Retain these instructions for maintenance reference.  
New Construction  
NOTE: I.C. Frame-In Kit may be used in direct contact with insulation.  
Fig. B  
Wire-In  
Fig. C  
Swing-Up  
Fig. D  
Close-In  
Fig. E  
Snap-On  
Fig. F  
Push-Up  
Fig. A  
Frame-In  
Warning: Use Only With Lightolier Reflector Trims Marked With I.C. Lamping Information.  
Use of Other Manufacturers’ Trims Voids the Underwriters Laboratories Listing and Could Constitute A Fire Hazard  
1. FRAME-IN (Fig. A)  
Locate fixture along joist and line up bottom edge of HINGEd MOUNTING BAR  
BENd AT HOLE  
TAB  
with the bottom of joist and fasten in place.  
5 3/4" 200ꢀFR  
5 ꢀ/4" ꢀ004ICX  
5 5/8" ꢀꢀ0ꢀFIC  
BENd AT TAB  
CENTER LINE OF  
APERTURE OPENING  
5 7/8" 200ꢀFIC  
For suspended ceilings:  
Rotate HINGEd BAR ENdS to position shown and fully extend bars.  
Crimp bottom of edge of CHANNEL to prevent rotation of  
HINGEd BAR ENdS.  
6 3/8" ꢀ00ꢀFIC  
6"  
ꢀꢀ0ꢀFIC  
Bend NON-HINGEd end of mounting bar at featured hole location and  
extend out.  
Position notched area of MOUNTING BARS onto T-BAR and lock by  
bending TAB underneath T-BAR BEAd as shown.  
For suspended ceiling, make certain that bottom of Mounting Frame is no  
higher than ꢀ" above ceiling line.  
Note: Integral nail version available  
HINGEd MOUNTING BAR  
T-BAR  
HINGEd BAR ENdS  
CHANNEL  
TAB  
For Joist Spacing Less Than 16" On Center (To 12" On Center):  
MOUNTING BAR CHANNELS can be shortened and used as nailing  
legs in tight spaces. Simply remove INNER BAR from holed CHANNEL,  
bend CHANNEL at appropriate point and use extra screw to secure it  
to the joist. (Fig. G)  
Fig. G  
Lightolier a Genlyte company  
63ꢀ Airport Road, Fall River, MA 02720 • (508) 679-8ꢀ3ꢀ • Fax (508) 674-47ꢀ0  
We reserve the right to change details of design, materials and finish.  
© 2007 Genlyte Group LLC • B0607  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Lenovo Cell Phone S920 User Manual
Lenoxx Electronics Furnace O23 User Manual
LG Electronics DVD Player GSA 4165B User Manual
Life Fitness Treadmill M051 00K60 A093 User Manual
LST Network Card RL58 1 User Manual
Magma Gas Grill A10 007 A10 017 A10 008 A10 018 A10 027 A10 027NZ A10 037 A10 037NZ User Manual
Maytag Microwave Oven MMV5156AA User Manual
McCulloch Chainsaw 964830301 User Manual
Melissa Hot Beverage Maker 745 191 User Manual
Metabo Cordless Sander BF 18 LTX 90 User Manual