Lightolier Indoor Furnishings 1004ICVN User Manual

INSTRUCTION SHEET NO.  
READ AND UNDERSTAND THESE INSTRUCTIONS BEFORE INSTALLING FIXTURE  
This fixture is intended for installation in accordance with the National Electrical Code and local regulations.  
To assure full compliance with local codes and regulations, check with your local electrical inspector before  
installation. To prevent electrical shock, turn off electricity at fuse box before proceeding.  
Retain these instructions for maintenance reference.  
IS:1004ICV  
B1204 Page 1 of 4  
INSTALLATION PROCEDURE FOR LOW VOLTAGE  
INSULATED CEILING FRAME-IN-KIT 1004ICV, 1004ICVN  
NEW CONSTRUCTION  
NOTE: I.C. Frame-in Kit may be used in direct contact with insulation.  
Fig. B  
Wire-In  
Fig. C  
Swing-Up  
Fig. D  
Close-In  
Fig. E  
Snap-On  
Fig. F  
Push-Up  
Fig. A  
Frame-In  
WARNING: USE ONLY WITH LIGHTOLIER REFLECTOR TRIMS MARKED WITH I.C. LAMPING INFORMATION. USE OF OTHER  
MANUFACTURERS’ TRIMS VOIDS THE UNDERWRITERS LABORATORIES LISTING AND COULD CONSTITUTE A FIRE HAZARD  
1. FRAME-IN (Fig. A)  
BEND AT HOLE  
TAB  
Locate fixture along joist and line up bottom edge of HINGED  
MOUNTING BAR with the bottom of joist and fasten in place.  
BEND AT TAB  
5 5/8”  
For suspended ceilings:  
• Rotate HINGED BAR ENDS to position shown  
CENTER LINE OF  
APERTURE OPENING  
and fully extend bars.  
6”  
• Crimp bottom of edge of CHANNEL to prevent  
rotation of HINGED BAR ENDS.  
• Bend NON-HINGED end of mounting bar at  
featured hole location and extend out.  
• Position notched area of MOUNTING BARS onto  
Note: Integral nail version available  
T-BAR and lock by bending TAB underneath  
T-BAR BEAD as shown.  
HINGED MOUNTING BAR  
• For suspended ceiling, make certain that bottom  
of Mounting Frame is no higher than 1” above  
ceiling line.  
T-BAR  
HINGED BAR ENDS  
CHANNEL  
FOR JOIST SPACING LESS THAN 16” ON CENTER (TO 12” ON CENTER):  
• MOUNTING BAR CHANNELS can be shortened and used as  
nailing legs in tight spaces. Simply remove INNER BAR from  
holed CHANNEL, bend CHANNEL at appropriate point and  
use extra screw to secure it to the joist. (Fig. G)  
TAB  
Fig. G  
®
LIGHTOLIER a GENLYTE company.  
631 Airport Road, Fall River, MA 02720  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTRUCTION SHEET NO.  
READ AND UNDERSTAND THESE INSTRUCTIONS BEFORE INSTALLING FIXTURE  
This fixture is intended for installation in accordance with the National Electrical Code and local regulations.  
To assure full compliance with local codes and regulations, check with your local electrical inspector before  
installation. To prevent electrical shock, turn off electricity at fuse box before proceeding.  
Retain these instructions for maintenance reference.  
IS:1004ICV  
B1204 Page 3 of 4  
Fig. H  
MALE CONNECTORS  
8. LAMPING (Fig. H)  
INSULATING SLEEVING  
(ATTACHED TO SOCKET WIRES)  
1. Make sure that power is OFF when lamping or relamping.  
Remove LAMP RING from TRIM by pulling straight down.  
2. Remove LAMP SHIELD from LAMP RING.  
3. Place LAMP SHIELD on back of LAMP (MR-16) and insert both  
FEMALE CONNECTORS  
(ATTACHED TO FIXTURE WIRES)  
between LAMP SPRINGS until face of lamp sits firmly on GLASS LAMP  
GUARD (Fig. J).  
MR16 SOCKET  
WARNING: RISK OF FIRE. LAMP SHIELD MUST BE INSTALLED.  
Fig. J  
4. Attach SOCKET to bi-pin prongs on LAMP.  
LAMP  
SOCKET  
5. Insert LAMP RING with LAMP SHIELD, LAMP and GLASS LAMP  
LAMP SHIELD  
LAMP SPRING  
GUARD back into TRIM.  
LAMP RING  
GLASS LAMP GUARD  
WARNING: 1. LAMP MANUFACTURERS REQUIRE THE GLASS LAMPGUARD BE IN PLACE BEFORE ENERGIZING LAMP, AND THAT GREAT  
CARE MUST BE TAKEN THAT LAMP IS FULLY COOLED BEFORE RELAMPING. AVOID FINGER MARKS ON INSIDE OF LAMP FOR THEY MAY  
CAUSE SHORT LAMP LIFE AND POSSIBLE BREAKAGE. 2. USE ONLY REFLECTOR TRIMS PROVIDED BY LIGHTOLIER INC. USE OF OTHER  
MANUFACTURER'S REFLECTOR TRIMS VOIDS THE UNDERWRITERS LABORATORIES LISTING AND COULD CONSTITUTE A FIRE HAZARD.  
NOTE: 1. LOW VOLTAGE FIXTURES should be  
dimmed only with special dimmers intended  
specifically for that purpose. Use Lightolier  
Lytemode, Scenist, Crescendo VA, Neptune VA,  
Precision VA, Easyset VA, Sunrise VA, Radiant  
VA or equivalent products by others or variable  
autotransformers or electronic dimmers  
intended for use with low voltage fixtures.  
2. Low voltage fixtures may produce audible  
sound which may be objectionable in acousti-  
cally critical areas.  
®
LIGHTOLIER a GENLYTE company.  
631 Airport Road, Fall River, MA 02720  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTRUCTION SHEET NO.  
READ AND UNDERSTAND THESE INSTRUCTIONS BEFORE INSTALLING FIXTURE  
This fixture is intended for installation in accordance with the National Electrical Code and local regulations.  
To assure full compliance with local codes and regulations, check with your local electrical inspector before  
installation. To prevent electrical shock, turn off electricity at fuse box before proceeding.  
Retain these instructions for maintenance reference.  
IS:1004ICV  
B1204 Page 4 of 4  
9. TRANSFORMER REPLACEMENT (Fig. K)  
1. Make sure power is off.  
2. Remove REFLECTOR TRIM from ceiling.  
3. Remove SCREW and lift TRANSFORMER off bracket.  
4. Remove J-BOX COVER by removing wing nut.  
5. Unsplice primary leads in J-BOX.  
PRIMARY  
LEADS  
6. Remove primary leads from J-BOX cover and clip attached to side  
SECONDARY  
(RED) LEADS  
of housing.  
7. Cut secondary (red) leads 6" to 8" from TRANSFORMER and dis-  
card faulty transformer.  
8. Install new TRANSFORMER:  
CLIP SCREW  
(WARNING: RISK OF FIRE. Transformer contains fixture thermal  
protector. Replace as shown and described below. Use only  
replacement transformer obtained from LIGHTOLIER.)  
a. Splice secondary (red) leads to socket leads.  
ROTO CLIPS  
JUNCTION BOX  
TRANSFORMER  
MAX. OF (6) #12 AWG BRANCH  
CIRCUIT CONDUCTORS SUITABLE  
FOR AT LEAST 90° C PERMITTED  
IN JUNCTION BOX.  
PRIMARY: 120V, 60HZ  
b. Attach TRANSFORMER to BRACKET with SCREW, making  
sure that the side of transformer that has the wire leads is  
facing the housing wall (Fig.L)  
SECONDARY: 110V, 50W LOAD  
Fig. K  
c. Put primary leads through clip and bushing in the J-BOX  
COVER.  
e. Wire primary leads to supply leads.  
f. Replace J-BOX COVER.  
g. Install REFLECTOR TRIM.  
WIRE LEADS  
APERTURE  
HOLE  
HOUSING  
WALL  
TRANSFORMER  
Fig. L  
®
LIGHTOLIER a GENLYTE company.  
631 Airport Road, Fall River, MA 02720  
Download from Www.Somanuals.com. All Manuals Search And Download.  

La Crosse Technology Portable Radio TX31U IT User Manual
Lanier Copier LW 210 User Manual
Legacy Car Audio Car Video System LDVD35 User Manual
Life Fitness Bicycle SR30 User Manual
Lightolier Indoor Furnishings VTS2GPK3FT User Manual
LST Smoke Alarm SG70 1 User Manual
Magnavox CRT Television TS2746C1 User Manual
Makita Grinder GA7011Cx User Manual
Makita Saw 5008NB User Manual
Meridian America Projector D ILA 1080MF1 User Manual