Lenoxx Electronics Indoor Fireplace L30 BF 2 User Manual

INSTALLATION AND OPERATION  
MANUAL  
FREESTANDING  
VENTED GAS  
FIREPLACE  
HEATER  
RETAIN THESE  
INSTRUCTIONS  
FOR FUTURE  
REFERENCE  
Shown with optional gold door and brickaded interior  
MODELS L30 BF-2 (B-Vent)  
P/N 775030M, IR, 06/01  
WARNING  
If the information in this manual is not followed exactly, a fire or explosion may result causing  
property damage, person injury or loss of life.  
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any  
other appliance.  
WHAT TO DO IF YOU SMELL GAS  
Do not try to light any appliance.  
Do not touch any electrical switch.  
Do not use any phone in your building.  
Immediately call your gas supplier from a neigh-  
bor's phone. Follow the gas supplier's instructions.  
If you cannot reach your gas supplier, call the  
fire department.  
Installation and service must be performed by a qualified installer, service agency or gas supplier.  
This appliance is only for use with the type(s) of gas indicated on the rating plate. This appliance is  
not convertible for use with other gases, unless a certified kit is used.  
Report No.  
189122-1050009  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TABLE OF CONTENTS  
Important Warnings ................................................ 2  
Testing / Listing, Using this Manual ........................ 3  
Planning Your Installation ..................................... 4-6  
Installation .......................................................... 7-11  
Care and Operation........................................... 12-13  
Propane Conversion.......................................... 14-15  
Maintenance...................................................... 16-17  
Wiring Diagrams..................................................... 18  
Troubleshooting...................................................... 19  
Replacement Parts / Optional Accessories............ 20  
Specifications ......................................................... 21  
Safety / Listing Label.............................................. 22  
Ownership Record and Service Log ...................... 23  
CONGRATULATIONS ON THE PURCHASE OF  
YOUR NEW GAS APPLIANCE MANUFACTURED BY  
LENNOX HEARTH PRODUCTS.  
When you purchased your new gas fired heater, you  
joined the ranks of thousands of concerned indi-  
viduals whose answer to their home heating needs  
reflects their concern for aesthetics, efficiency and  
our environment. We extend our continued support  
to help you achieve the maximum benefit and en-  
joyment available from your new gas fired heater.  
It is our goal at Lennox Hearth Products to provide  
you, our valued customer, with an appliance that  
will ensure you years of trouble free warmth and  
pleasure.  
Thank you for selecting a Lennox Hearth Products  
gas fired heater as the answer to your home heating  
needs.  
Sincerely,  
All of us at Lennox Hearth Products  
TESTING / LISTING  
This appliance is tested and certified as safe for resi-  
dential use by an internationally recognized testing and  
certification agency. The safety tests are conducted in  
accordance with American National Standards Institute  
(ANSI) requirements. The L30 BF-2 appliance is tested,  
certified, and listed by the CSA, AGA, CGA to ANSI  
Z21.88 - 1998 Vented Gas Fireplace Heaters and CSA  
2.33 - 1998 Vented Gas Fireplace Heaters.  
Approved Venting: This appliance may be vented with  
any listed class B chimney components installed in ac-  
cordance with manufacturers instructions. See page 7.  
PACKAGING LIST  
This appliance is packaged with an accessory package,  
which contains the following:  
One - Installation and operation instructions manual.  
One - Warranty.  
One - Log set and embers.  
One - LP conversion kit.  
One - 9’ electrical power cord.  
USING THIS MANUAL  
Please read and carefully follow all of the instructions  
found in this manual. Please pay special attention to the  
safety instructions provided in this manual. Following  
the Homeowner’s Care and Operation Instructions in-  
cluded here will assure that you have many years of  
dependable and enjoyable service from your appliance.  
PAGE 3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PLANNING YOUR INSTALLATION  
LOCAL AND NATIONAL CODE REQUIREMENTS  
The installation of these appliances must conform with  
local codes or, in the absence of local codes, with the  
National Fuel Gas Code, (for USA) NFPA 54 / ANSI  
Z223.1-latest edition.  
GAS PRESSURE (WC = Water Column)  
Minimum inlet gas supply pressure for the purpose  
of input adjustment:  
Natural Gas - 4.5” WC min. – 7.0” WC max.  
Propane (LP) - 11” WC min - 13.0” WC max.  
Air Circulation Blower: The blower electrical power  
cord must be electrically grounded per local codes or  
per electrical codes:  
Manifold gas supply pressure:  
LOW  
Natural Gas - 1.8” + / -.3” WC (to) 3.5” + / -.3” WC  
25,000 BTU / hr 37,000 BTU / hr  
HIGH  
In USA, NEC, ANSI / NFPA 70-1987.  
In Canada, CSA C22.1  
Propane (LP) 6.6” + / -.3” WC (to) 10” + / -.3” WC  
WARNING  
28,000 BTU / hr  
35,000 BTU / hr  
Electrical Grounding Instructions. This ap-  
pliance is equipped with a three-prong  
(grounding) plug for your protection against  
shock hazard and should be plugged di-  
rectly into a properly grounded three-prong  
receptacle. Do not cut or remove the  
grounding prong from this plug.  
Note: ” WC = Inches Water Column  
PRESSURE TAPS  
Gas Inlet Pressure Tap - Located on bottom left of gas  
valve.  
Gas Outlet (manifold) pressure tap - Located on bottom  
right of gas valve.  
WARNING: To avoid electrical shock, always ensure  
that the power cord is unplugged (i.e., there is no elec-  
trical power to the circulation blower) before handling  
the circulation blower or performing any work on the  
appliance.  
Gas Control Valve  
High Altitude: Gas inputs shown are for elevations up  
to 4500 feet. For elevations above 4500 feet, contact  
your gas supplier or qualified service technician re-  
garding the necessary deration of appliance (deration:  
replacing burner orifice with a smaller one to reduce  
input). Ratings must be reduced at the rate of 4 percent  
for each 1,000 feet above sea level. Refer to (for USA)  
NFPA 54 / ANSI Z223.1-latest edition for orifice resiz-  
ing.  
TOOL / EQUIPMENT LIST  
Pressure Testing: See Pressure Testing on page 8.  
The following tools and equipment are recommended  
for completing the partial assembly required when the  
appliance is installed:  
7/16”, 3/4” open end wrenchs.  
1/4”, 3/8” nut drivers.  
Pipe wrench.  
Phillips head screw driver.  
Flat head screwdriver.  
Pipe sealant compound.  
Leak test fluid“U” tube manometer or pressure gauge (0 -  
16” (inches water column) H2O scale.  
PAGE 4  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PLANNING YOUR INSTALLATION  
QUESTIONS TO ASK THE LOCAL BUILDING OFFI-  
CIAL  
5. In some states or municipalities, a licensed gas fit-  
ter or plumber may be required to install this appli-  
ance. Check with your local building official for re-  
quirements in your area (i.e. Is a license required  
for installation of gas supply line)?  
Correct installation is critical and imperative for reducing  
fire hazards and perilous conditions that can arise when  
gas appliances function improperly. The appliance must  
be installed per manufacturers’ instructions.  
6. Maximum amount of gas pipe without a pressure  
test - type of test required?  
Gas appliance equipment and installations must con-  
form to appropriate local codes and applicable state  
and federal requirements. Familiarity with these re-  
quirements before installation is essential. Important  
considerations to discuss with local building officials  
include:  
7. Are below grade penetrations of the gas line al-  
lowed?  
8. Is concealed gas piping allowed?  
9. Specific requirements of concealed fittings?  
10. Is rigid pipe to appliance required?  
1. Applicable codes (i.e. Uniform Mechanical Code,  
State or Regional Gas Codes, National Fuel Gas  
Code)?  
11. Allowed piping materials?  
2. Local amendments?  
12. Shut-off valve required within 4 feet of the firebox?  
13. May the shut-off valve be concealed?  
14. Rooms where the installation is not allowed?  
3. Recognized testing lab: CSA / AGA.  
4. Is a permit required - cost?  
In the absence of local codes, installation should  
conform to the National Fuel Gas Code, also known  
at ANSI Z223.1-NFPA 54.  
PAGE 5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PLANNING YOUR INSTALLATION  
CLEARANCES TO COMBUSTIBLE MATERIALS  
These appliances can be installed in most residential room  
configurations, parallel to a rear or adjacent wall, or in an  
alcove that allows for the minimum clearances to combus-  
tible surfaces. Your local building inspector should review  
your plans prior to installation.  
Rear Wall or Alcove  
When installing this appliance, provide adequate clear-  
ances around air openings and adequate clearances for  
purposes of servicing and proper operation.  
As determined through the safety certification of this unit,  
a minimum clearance to combustible materials must be  
maintained around specific areas of the gas appliance.  
(See Figures 1, 2 and 3)  
The clearances listed here are minimum distances and  
only apply in the configuration shown. Do not use clear-  
ances from one installation configuration with clearances  
from another to obtain closer clearances.  
Top of appliance (min.)  
36”  
(inches)  
This includes any projections such as shelves, window sills,  
mantels, etc. above the appliance.  
Back Wall  
Side Wall  
2" (inches)  
12" (inches)  
4" (inches)  
Fig. 1  
Corner (45° angle)  
stove corners to wall  
Ceiling Minimum  
Alcove Min. Height  
Alcove Min. Width  
Alcove Max. Depth  
Corner  
65" (inches) from floor  
65" (inches) from floor  
54" (inches)  
24" (inches) from unit face.  
The stove can not be placed deeper into an alcove than 24” from  
the stove face to alcove opening.  
Floor  
0 inches  
FLOOR PROTECTION  
When installed directly on carpeting, tile or other com-  
bustible material other than wood flooring, the appliance  
shall be installed on a metal or wood panel extending the  
full width and depth of the appliance (see note below).  
Fig. 2  
Notes:  
Ceramic tile is non-combustible and does not require  
a wood or metal panel under the appliance.  
Models with a pedestal base where base dimensions  
exceed width and depth of stove body, qualify as the  
floor protection  
Rear Wall or Alcove  
Fig. 3  
PAGE 6  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION See Pipe Manufacturers clearances for Pipe Clearances Venting Requirements  
EXAMPLES OF VENTING INSTALLATION APPLICATIONS  
Model: L30 BF-2 (B-Vent) Venting Requirements  
Approved for vertical termination only.  
Venting Configuration Requirements:  
A minimum of 5 feet vertical pipe is required to vent the  
appliance. Lengthy horizontal pipe runs require sufficient  
length of vertical pipe to deliver adequate draft. Use the  
table above as a guide in planning your installation. The  
use of multiple 45° or 90° elbows should be compen-  
sated by providing additional vertical pipe run.  
This appliance has a 4” B-Vent flue collar and may be  
installed with listed B-Vent piping and components.  
Refer to the pipe manufacturer’s installation instructions  
for specific requirements for their product. Maintain  
proper clearances to combustible materials as specified  
by the pipe manufacturer. Whenever vent pipe is run  
horizontally, maintain a minimum 1/4” rise per foot. Exte-  
rior B-Vent exhaust systems should be enclosed in a  
chase to avoid rapid cooling of exhaust gases in the  
vent. Such cooling could produce condensation of flue  
gases or exhaust gas spillage. The use of a chase is  
highly recommended in colder climates.  
VERTICAL VENT TERMINATION REQUIREMENTS  
The vent termination clearances above the high side of an  
angled roof is follows:  
Ref. NFPA 54 / ANSI Z223.1, 7.6  
Roof Pitch  
Flat to 6/12  
6/12 to 7/12  
7/12 to 8/12  
Feet  
1.0  
1.25  
1.5  
2.0  
2.5  
3.25  
4.0  
5.0  
6.0  
7.0  
7.5  
8.0  
Meters  
0.3  
0.38  
0.46  
0.61  
0.76  
0.99  
1.22  
1.52  
1.83  
2.13  
2.29  
2.44  
8/12 to 9/12  
9/12 to 10/12  
10/12 to 11/12  
11/12 to 12/12  
12/12 to 14/12  
14/12 to 16/12  
16/12 to 18/12  
18/12 to 20/12  
21/12 to 21/12  
Maximum Horizontal Pipe Runs for Given Vertical Pipe  
Run (in feet)  
Vertical run  
in feet  
5’  
4’  
6’  
6’  
8’  
8’  
10’  
10’  
15’  
15’  
20’  
20’  
Maximum  
horizontal  
run in feet  
Note: Maximum allowable horizontal pipe run is 20  
feet.  
PAGE 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION  
The appliance must be isolated from the gas supply piping  
system by closing its individual manual shut-off valve during  
any pressure testing of the gas supply piping system at test  
pressures equal to or less than *1/2 psi (3.5 kPa).  
GAS SUPPLY HOOKUP  
If using pipe other than black iron pipe see NFPA 54-National  
Fire Protection Association / ANSI Z223.1-American National  
Standards Institute; and local code for specific requirements  
for the type of pipe used. Alternative gas piping systems such  
as CSST may be used subject to local code and proper sizing.  
Make the connection to the gas supply line using the  
correct fitting required to the shut-off valve.  
Install a drip leg where condensates might accumu-  
late. Sediment traps, like drips and collection tees, are  
required to be installed. Traps collect moisture and  
intercept and hold foreign objects which might block  
orifices and valves. A drip leg should be installed in  
vertical pipe runs to the appliance.  
This appliance is equipped with a flexible gas line and  
fitting for a gas supply line connection. Connection can  
be made using either the 3/8” NPT male fitting or, by re-  
moving the fitting, to the flex line 3/8” female flare. The  
flex line can be routed to the gas supply through either  
the pedestal bottom or through the rear pedestal cover  
depending upon the orientation of the supply line. Some  
areas may have certain restrictions against the use of  
flexible gas lines. Check local codes. The gas appliance  
control valve has a 3/8” NPT female type inlet for the gas  
supply line, if hard plumbing is required.  
Supply Line Size Requirements  
The proper gas line diameter must be used to run  
from the supply regulator (at the gas company meter)  
to the appliance. Never use galvanized or plastic  
pipe. Refer to the table below for suggested sizing of  
the gas supply line.  
Suggested Sizing of  
Schedule 40 Pipe Supply Line  
Schedule 40 Pipe  
Schedule 40 Pipe  
Length (Feet)  
If the gas supply will be routed to the appliance from the  
rear, the flexible gas line for hookup is readily accessible.  
If the gas supply will be routed to the appliance through  
the flooring, remove the rear panel. Redirect the flexible  
gas line through the large hole in the center of the ped-  
estal base for gas supply connection.  
Inside Diameter (Inches)  
Natural Gas  
LP. Gas  
3/8  
0-10  
1/2  
1/2  
1/2  
3/4  
3/4  
10-40  
1/2  
40-100  
100-150  
150-200  
1/2  
A gas supply line must be run to the appliance by a quali-  
fied professional. The plumbing of the gas line must  
comply with National Standards; NFPA 54-National Fire  
Protection Association / ANSI Z223.1-American National  
Standards Institute; and local code.  
1/2  
1/2  
Use an approved pipe sealant compound for NPT fit-  
tings. After all pipe connections are made, apply  
normal gas line pressure: 7.0” W.C. for natural gas;  
11.0” W.C. for LP gas (propane) and use an approved  
leak detection solution to test for the tightness of each  
pipe connection joint.  
Gas piping must not run in or through air ducts, clothes  
chutes, chimneys or gas vents, dumb waiters or elevator  
shafts.  
Piping should be sloped 1 / 4” per 15 feet (6mm per  
4.6m) upward toward the meter from the appliance. The  
piping must be supported at proper intervals every 8 to  
10 ft. (2.4m to 3.1m) using suitable hangers or straps.  
The gas supply line must be purged of air before it is  
connected to the appliance.  
An accessible, approved shut-off valve must be installed  
upstream of any connector so that the appliance may be  
isolated to allow service, removal, and replacement  
(within six feet of the appliance per NFPA 54, or twelve  
inches in some codes). A shut-off valve is provided with  
this appliance.  
IMPORTANT: All connections must be checked for leaks with  
a leak detector or soapy water solution. Never check for gas  
leakage with an open flame!  
IMPORTANT: In case emergency shut-off is required,  
shut off main manual gas valve and disconnect main  
power to appliance. These devices should be properly  
labeled by the installer.  
PRESSURE TESTING:  
* Note: ½ psi = 14” WC (inches water column).  
The appliance main gas valve must be disconnected from the gas  
supply piping system during any pressure testing of that system at  
test pressures in excess of *1/2 psi (3.5 kPa).  
PAGE 8  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION  
DOOR OPERATION  
b. Open the two draw latches mounted on the right  
side of the door by pulling them forward. Swing  
open door. See picture in left column of this page  
showing their location.  
c. With the door open, lift the door straight up and  
off the hinge pins. Set door aside.  
After setup of the logs and embers is complete, the glass  
door must be closed. The glass door is mounted on  
hinges at the left side of the firebox and is secured in the  
closed position by two draw latches mounted on the right  
side of the firebox. The latch tension is preset at the  
factory. Over time, adjustment of the latch tension may  
be necessary to maintain a tight door seal. This adjust-  
ment can be made by spinning the latching rod in the rod  
guide. Care should be exercised to not adjust the ten-  
sion too high. Caution: Never operate the appliance  
with the glass door open.  
If glass door removal is required for replacement or  
maintenance, the door can be removed Do not attempt to  
remove or replace broken glass in the door assembly.  
Contact your Lennox dealer for glass replacement. To  
Remove Door:  
1. Remove the glass door assembly from appliance  
as follows:  
a. Open the right and left side panels (held closed  
by magnets in the front. The panels hinge to  
back).  
PAGE 9  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION  
GAS APPLIANCE FINAL ASSEMBLY  
4. Install the center top twig as shown in the following  
illustration.  
After the appliance has been properly installed and all  
gas connections have been made and tested, you can  
now install the log set. See Door Assembly on page 11  
for door removal instructions.  
INSTALLING LOG SET:  
WARNING: If logs are not installed according to the  
directions in this manual, flame impingement and  
improper combustion could occur and result in ex-  
cessive production of carbon monoxide (CO), a col-  
orless, odorless, toxic gas.  
This appliance is equipped with a five-piece log set.  
Carefully install the logs into the firebox as shown on  
this page. All logs should fit down onto pins and mounts  
provided. This will ensure a proper flame and safe  
combustion.  
5. Install the left top twig and embers as shown in the  
following illustration.  
1. Carefully place the largest log in the rear of the fire-  
box as shown in the following illustration.  
2. Install the front log as shown in the following illustra-  
tion.  
Glowing Embers  
One package of ember material has been included with  
this gas appliance. You will not need to use the entire  
bag (additional ember material is provided for your fu-  
ture maintenance needs).  
IMPORTANT: The quantity and placement of the  
ember material can affect stove performance there-  
fore it is very important that it be placed as shown  
in the picture on instruction # 5 and shown below.  
Proper Placement of Ember Material: Unpackage and  
divide the fine ember material (mineral wool) into  
thumbnail sized fluffy pieces. Distribute the pieces over  
the top of the front burner ports and filling the area in  
front of and beneath the forward log and running the full  
length of the log.  
3. Install the right top twig as shown in the following  
illustration.  
PAGE 10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION  
2. Adjust gap as shown in following picture.  
INSTALLATION CHECK LIST  
Read and understand these instructions before using  
appliance. Go through this installation checklist:  
G
Ensure that the log set is properly installed. Use cau-  
tion when handling the logs. See page 10.  
G
Reinstall the door frame assembly. See Door Opera-  
tion on page 9.  
WARNING: Do not operate appliance with the  
glass front removed, cracked or broken. Re-  
placement of the glass should be done by a  
qualified technician.  
3. Reinstall burner. Do not overtighten nuts  
(finger tight only).  
G
G
Ensure venting termination cap is unobstructed.  
G
Light the appliance following the instructions on page  
13 (Care and Operation). Relight the main burner in  
both the HI, and LO positions, and verify proper  
burner ignition and operation.  
Check to see that wiring is correct and is enclosed  
inside the stove pedestal base (See page 18).  
G
G
Verify that the gas line has been purged of air.  
NOTE: Upon the initial firing of your new gas stove,  
you will notice a strong odor. This will last up to two  
hours. It is recommended to open the windows to  
allow fresh air to circulate into the room.  
Test all connections for leaks (factory and field) with  
a leak detector or soapy water solution. If you smell  
gas, do not attempt to light this appliance. Follow  
safety instructions on the front cover of this manual.  
WARNING: If the pilot does not light after 1 min-  
ute, wait at least 5 minutes for gas to clear before  
attempting again.  
G
Burner Air Shutter opening to be:  
Natural Gas – 1/2 open, Propane 3/4 open.  
G
With burner lit, check to make sure that the inlet gas  
and manifold pressures are correct (see Gas Pres-  
sure, page 4). Verify that the pilot and main burner  
ignition and operation are correct.  
Some adjustment from standard may be necessary  
for the desired flame characteristics (see Burner  
Flame Appearance, page 17). To adjust air shutter:  
1. Remove burner from firebox by removing the 2  
nuts as shown in the following picture. Then lift  
burner up and out of firebox.  
PAGE 11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
                                                                                                                                  
                                                                                                                                  
                                                                                                                         
                                                                                                                         
                                                                                                                 
                                                                                                                 
                                                                                                                                     
                                                                                                                                     
CARE AND OPERATION  
FOR YOUR SAFETY READ BEFORE LIGHTING  
WARNING: If you do not follow these instruc-  
tions exactly, a fire or explosion may result  
causing property damage, personal injury or  
loss of life.  
A. This appliance has a pilot which must be lit.  
When lighting the pilot, follow these instructions  
exactly.  
B. BEFORE LIGHTING smell all around the appli-  
ance area for gas. Be sure to smell next to the  
floor because some gas is heavier than air and will  
settle on the floor.  
LIGHTING AND SHUTDOWN INSTRUCTIONS  
1. STOP! Read the safety information on this page or on label  
(on appliance).  
2. Turn off all electrical power to the appliance (unplug blower  
power cord). Make sure the burner ON/OFF switch is in the  
OFF position.  
3. To gain access to the gas controls, swing the control access  
door open. The control access door is located directly under  
the window.  
4. Push in gas control knob slightly and turn clockwise 2 to  
“OFF.”  
NOTE: Knob cannot be turned from “PILOT” to “OFF” un-  
less knob is pushed in slightly. Do not force.  
5.Wait five (5) minutes to clear out any gas. Then smell for  
gas, including near the floor. If you smell gas, STOP! Fol-  
low “B” in the safety information above on this label. If you  
don’t smell gas, go to the next step.  
WHAT TO DO IF YOU SMELL GAS:  
Do not try to light any appliance.  
Do not touch any electric switch; do not use  
any phone in your building.  
Immediately call your gas supplier from a  
neighbor’s phone. Follow the gas supplier’s in-  
structions.  
6.Visually locate the pilot located in the center of the firebox  
beneath the rear ceramic log.  
If you cannot reach your gas supplier, call the  
fire department.  
7.Turn knob on gas control counterclockwise 3 to “PILOT.”  
8.This appliance contains a spark ignition system (piezo ig-  
niter), which is used to light the pilot. Push in the gas control  
knob all the way and hold it in. Immediately press the button  
on the piezo igniter located to the left of the gas control knob.  
The spark produced by the piezo igniter should light the pilot.  
Continue to hold the control knob in for about one (1) minute  
after the pilot is lit. Release the gas control knob and it will  
pop back up. Pilot should remain lit.  
C. Use only your hand to push in or turn the gas  
control knob. Never use tools. If the knob will not  
push in or turn by hand, don’t try to repair it, call a  
qualified service technician. Force or attempted  
repair may result in a fire or explosion.  
D. Do not use this appliance if any part has been un-  
der water. Immediately call a qualified service  
technician to inspect the appliance and to replace  
any part of the control system and any gas control  
which has been under water.  
If it goes out, repeat steps 4 through 8.  
If the knob does not pop up when released, stop and im-  
mediately call your service technician or gas supplier.  
If the pilot will not stay lit after 3 or 4 tries, turn the gas con-  
trol knob to “OFF” and call your service technician or gas  
supplier.  
Gas Control Valve  
9. Turn gas control counterclockwise 3 to “ON.” Use rocker  
switch, located either on the control panel or the exterior  
side panel, to operate main burner. Adjust variable pres-  
sure dial (RB Regulator / Flame Height Control) to set  
burner flame to desired heat output.  
10. Swing the control access door closed.  
11. Turn on electrical power to the appliance (plug in blower  
power cord. See page 13, Circulation Blower Operation.)  
TO TURN OFF GAS TO THE APPLIANCE  
1. Turn off all electric power to the appliance if service is to be  
performed.  
2. To gain access to the gas controls, swing the control ac-  
cess door open. The control access door is located directly  
under the window.  
Pilot Assembly  
3. Push in gas control knob slightly and turn clockwise 2 to  
“OFF.”  
NOTE: Knob cannot be turned from “PILOT” to “OFF” un-  
less knob is pushed in slightly. Do not force.  
4. Swing the control access door closed.  
PAGE 12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CARE AND OPERATION  
CIRCULATION BLOWER OPERATION  
“BREAK-IN” PERIOD  
The speed of the circulation blower is controlled using  
the speed control rheostat (see following illustration) on  
the left hand side of the control panel. The blower sys-  
tem is designed with a variable speed control allowing  
an infinite range of blower settings to meet the cus-  
tomer’s needs. With the rotary switch turned fully CCW  
3, the blower is off. Turning the switch CW 2 will acti-  
vate the blower at its maximum speed. Further rotation  
of the switch in the CW direction will reduce the speed  
of the blower. At approximately 270° of CW 2 rotation,  
the switch provides a minimum setting for blower  
speed.  
The finish on this appliance is a high temperature paint  
that requires time and temperature to completely cure.  
The curing process will take 2 or 3 burns (heat up and  
cool down periods). We recommend that you ventilate  
the house during the initial burns. The paint emits non-  
toxic odors during this process.  
KEEP YOUR HOUSE WELL VENTILATED DURING  
THE CURING PROCESS TO PREVENT ACTIVATION  
OF YOUR HOME SMOKE DETECTOR.  
Do not turn on a blower during the break-in period. Do  
not place anything on the stove surface until the paint is  
completely cured. Do not attempt to repaint the stove  
until the paint is completely cured. If the surface later  
becomes stained or marred, it may be lightly sanded  
and touched up with spray paint (See Small Area Paint  
Touch-Up, page 16). Paint is available at your local  
authorized Lennox Hearth Products dealer. Never at-  
tempt to paint a hot stove.  
Thermostatic feature: With the control switch in any  
“ON” position, the circulation blower is designed to  
automatically begin operation approximately 12 minutes  
after lighting the main burner. The blower will turn off  
approximately 15 minutes after the main burner is shut-  
off.  
PAGE 13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PROPANE CONVERSION  
PROPANE CONVERSION PROCEDURE  
(Only required if Propane gas is used)  
This appliance is designed to operate on natural gas, or  
propane (LP). It is factory set for use with natural gas  
and requires field conversion for use with propane. The  
use of other fuels or combination of fuels will degrade  
the performance of this system and may be dangerous.  
The conversion kit provided with this appliance contains  
components required to convert this appliance from use  
with natural gas to use with propane (LP) Gas. All of the  
components in the propane conversion kit must be in-  
stalled in order for the appliance to operate safely on  
propane.  
PROPANE Conversion Procedure  
1. Turn off Gas - Turn gas control knob to the off posi-  
tion, and shut off the gas supply to the valve. If nec-  
Installation Tools / Supplies  
7/16” Open end wrench  
Small standard screwdriver  
Pipe sealant compound (must be rated for use with  
LPG gas)  
essary, disconnect appliance from gas supply.  
2. Caution: The gas supply shall be shut off prior to  
disconnecting the electrical power, before proceed-  
ing with the conversion. Unplug blower power cord.  
3. If the installation is at an elevation below 4500 feet,  
proceed to step 4. If you are at an elevation above 4500  
feet, do not use the orifice provided in this kit. Contact your  
gas supplier to obtain a smaller orifice).  
Parts List  
Propane RB Regulator conversion screw (Red indicates  
LP gas)  
Burner Orifice (If you are at an elevation above 4500 feet  
do not use the orifice provided in this kit. Contact your  
gas supplier to obtain a smaller orifice)  
Pilot Orifice  
Label, Converted to (LP) Propane – Affix to valve  
Label, Converted to (LP) Propane – Affix to stove body  
4. Burner Orifice Installation Procedure:  
a. Remove glass door.  
b. Remove logs, burner cover, and burner.  
c. Use a 7/16” open-end wrench to remove gas  
burner orifice.  
Avertissement: cet équipement de conversion sera in-  
stallé par une agence qualifiée de service confor-  
mément aux instructions du fabricant et toutes exi-  
gences et codes applicables de l’autorisés avoir la ju-  
ridiction. Si l’information dans cette instruction n’est  
pas suivie exactement, un feu, explosion ou production  
de protoxyde de carbone peut résulter le dommages  
causer de propriété, perte ou blessure personnelle de  
vie. L’agence qualifiée de service est esponsable de  
l’installation propre de cet équipment. L’installation  
n’est pas propre et compléte jusqu’à l’opération de  
l’appareil converti est chéque suivant les critères établis  
dans les instructions de propriétaire provisionnées avec  
l’équipement.  
d. Replace the burner orifice with the appropriate  
burner orifice (see instruction #3).  
e. Use pipe sealing compound rated for LP gas. BE  
VERY CAREFUL THAT THE PIPE COMPOUND  
DOES NOT GET INSIDE OF THE ORIFICE  
(THIS COULD RESULT IN PLUGGING OF THE  
ORIFICE). Using a 7/16” open-end wrench to  
tighten orifice - DO NOT OVER TIGHTEN (finger  
tight, then 1/2 turn maximum). *Make sure the  
orifice is inserted fully into the primary air shutter  
fixed opening.  
5. Adjust primary air shutter. Burner Air Shutter open-  
ing to be: Natural Gas – 1/2 open, Propane 3/4  
open. Some adjustment from standard may be nec-  
essary for the desired flame characteristics (see  
Burner Flame Appearance, page 15).  
IN CANADA:  
The conversion shall be carried out in accordance with  
the requirements of the provincial authorities having  
jurisdiction and in accordance with the requirements of  
the CAN1-B149.1 and .2 Installation code.  
6. Replace Pilot Orifice - Using a 7/16” open-end  
wrench, remove the pilot burner hood. Replace the  
pilot orifice with the one supplied in the propane  
conversion kit. Then, reinstall the pilot burner hood.  
Ensure that the mark on the pilot hood is lined up  
with the mark on the pilot mounting plate.  
La conversion devra être effectuée conformément aux  
recommandations des autorités provinciales ayant ju-  
ridiction et conformément aux exigences du code  
d’installation CAN1-B149.1 ET.2.  
PAGE 14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PROPANE CONVERSION  
7. High / Low Pressure Regulator Installation Proce-  
dure:  
10. Purge air from the gas line (see #9 above), then  
connect propane gas line to the appliance. Connect  
the fuel line to the insert inlet (1/2” NPT fitting) using  
the fitting required.  
a.Remove regulator cap and conversion screw (see  
following illustration).  
b.Install the new conversion screw (Red = Propane  
LP gas, Blue = Natural Gas). Ensure that the con-  
version screw is finger tight. Install the new regu-  
lator cap.  
c.Affix conversion label on gas control valve body  
where it can easily be seen.  
11. Perform leak Test.  
CAUTION  
After this procedure is complete with appliance in-  
stalled and connected to gas line, recheck the pilot  
connection and manifold fittings for leaks, using  
soapy water or a gas leak detector.  
12. Lighting Procedure-See page 12.  
Note: If the gas control knob is turned to the “off” posi-  
tion after pilot has been lit, the appliance must be al-  
lowed to cool for at least five minutes before pilot flame  
can be relit.  
13. Apply the propane conversion label to the rating  
label.  
The Appliance is ready for use with propane fuel as its  
only fuel.  
REFERENCE INFORMATION  
See pages 4, 21 and 22 of this manual for the following  
reference information:  
Manifold Gas Pressure  
Inlet Gas Pressure  
Input Ratings  
BURNER FLAME APPEARANCE  
8. Reinstall burner cover, logs, ember wool / ceramic  
rocks and glass front.  
9. Purging Air from Supply Line:  
A periodic visual check of burner flames should be  
performed. The burner flame should appear as indi-  
cated on page 17 - Burner Flame Appearance.  
This should only be done by a qualified and li-  
censed (where applicable) professional. Check with  
your local building official for qualifications required  
to perform this procedure.  
PAGE 15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MAINTENANCE  
Always Turn Off Gas Control Valve Before Cleaning. Annual Maintenance Should Only Be  
Performed By A Qualified Service Technician:  
LOG SET  
CLEAN EXTERNAL SURFACES  
Removing & Cleaning Logs - Carefully remove the logs  
(removing top logs, then lifting front log out, then rear  
log). Use care when handling the fiber logs, as they be-  
come quite fragile after curing. Use a small soft-bristled  
brush (e.g., a nylon paint brush) to remove soot, dust or  
debris that may have accumulated on the burner or log  
set. Remove the logs and burner, and clean them out-  
side the home in a location with plenty of fresh air venti-  
lation. Avoid breathing fine particulates of dust that may  
be generated. See page 10, Installing Log Set for in-  
structions on reinstalling logs.  
External surfaces should be kept clean and dust re-  
moved form air inlets to the appliance. The flow of com-  
bustion and ventilation air must not be obstructed. The  
appliance must be kept clear and free from combustible  
materials, gasoline and other flammable vapors and liq-  
uids.  
SMALL AREA PAINT TOUCH-UP  
The stove body is painted with a quality high-temperature  
stove paint. Use only model TSPK-C Stove Paint, Cata-  
log # 19L92. Do not touch-up this appliance with any  
other paint.  
Replacing Logs - If logs become damaged by accident  
or improper handling and need replacement, use only the  
proper replacement logs from manufacturer, which can  
be purchased from your local dealer. See page 20.  
Using one small piece of 320 grit sand paper and lightly  
sand the blemish so that the edges are “feathered” or  
smooth to the touch between the painted and bare sur-  
faces. Do not let the sand paper gum up with paint, as  
this will cause scratches on the metal surface. If there  
are any scratches, use 600 grit sandpaper instead. Mask  
off surfaces you do not want painted. Paint lightly over  
the bare surface first as this will act as an undercoat.  
Then paint over a larger area in smooth even strokes to  
blend.  
CLEANING BURNER  
With the logs removed, vacuum out any foreign matter  
(lint, carbon etc.) on the burner. Be sure the burner ports  
are “open.”  
CLEANING VALVE / AIR VENTURI  
Clean all lint and dust build-up around the control valve  
and air shutter on the venturi. Inspect and clean with a  
brush or wire the inlet of the venturi for any spider webs  
or lint accumulation.  
See Break-In Period on page 13 for information on curing  
the paint.  
CLEANING GLASS  
The window on the gas appliance is made from a clear  
ceramic material and may be cleaned when cool with any  
non-abrasive product designed for use on glass win-  
dows. Do not use abrasive cleaners on glass. The  
viewing glass should be cleaned periodically. Exterior  
glass may be cleaned with a glass cleaner as desired.  
Interior glass - use soap and water, or commercial glass  
cleaner recommended for stove glass.  
INSPECT WIRING / CAUTIONS:  
Note: Each time the appliance is lit, it may cause con-  
densation and fog on the glass. This condensation and  
fog will disappear in a few minutes.  
1) Label all wires prior to disconnection when servicing  
controls. Wiring errors can cause improper and dan-  
gerous operation.  
2) Verify proper operation after servicing.  
3) Inspect and clean all wire connections. Ensure that  
there is no melting or damage from rodents. Inspec-  
tion should include:  
CLEANING BLOWER INTAKE  
The blower air intake requires cleaning at least once a  
year to remove lint, dust, etc. If there are pets in the  
dwelling, the intake should be cleaned at least twice a  
year.  
Terminals at the valve  
On / Off switch  
Wall Thermostat / Remote Control (optional kits)  
VENTING SYSTEM  
A periodic examination of the venting system must be  
performed to ensure that the flow of combustion air is not  
obstructed. We recommend that you have your gas ap-  
pliance checked yearly by your independent Lennox  
dealer.  
PAGE 16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MAINTENANCE  
Always Turn Off Gas Control Valve Before Cleaning. Annual Maintenance Should Only Be  
Performed By A Qualified Service Technician:  
PERIODIC CHECK OF PILOT AND BURNER  
FLAMES  
Check the operation of the pilot and cycle the burner.  
Visually check the flame of the burner making sure the  
flames are steady; not lifting or floating. The flame color  
should be blue at the burner with yellow body and tops.  
BURNER FLAME APPEARANCE  
A periodic visual check of the pilot and burner flames  
should be performed. If either the pilot or burner flame  
do not show proper appearance or behavior, as outlined  
here, consult a qualified gas appliance technician.  
Cycle unit a minimum of 2 times  
Watch for smooth burner ignition and shut down.  
Burner: Check flame patterns. Ensure that burner  
flame appearance does not vary greatly from dia-  
gram shown on this page.  
Pilot: Ensure pilot flame appearance does not vary  
greatly from diagram shown below.  
PILOT FLAME APPEARANCE  
A proper pilot flame should consist of torch-like flame  
issuing from the pilot hood as shown in illustration be-  
low.  
Proper Pilot Appearance  
A proper burner flame is shown above. The burner  
flame should have the following characteristics after  
initial start-up (let appliance burn 15 to 20 minutes prior  
to accessing flame appearance):  
Excessive impingement (contact of flame with  
logs) should not occur.  
Rear burner flames should have yellowish tips; no  
soot should form at burner flame tips.  
Flames should not raise off of burner (no “lifting”  
of flame).  
Air Shutter Adjustment  
The flame can be adjusted to give the proper flame ap-  
pearance and to prevent sooting on the window or logs  
by adjusting the position of the primary air shutter (lo-  
cated at the rear center inlet to the burner). The air  
shutter should be positioned approximately 1/2 open for  
Natural Gas and approximately 3/4 open for LP Gas. .  
See page 10, Burner Air Shutter.  
NOTE: During periods of high natural gas demand, the  
gas supplier may add “make-up gases” to the pipeline.  
This addition will change the composition of the supply  
gas, and may cause a change in burner flame appear-  
ance. You may also notice soot formation on the logs  
and viewing windows. Check with your gas supplier if  
you suspect a change in the composition of your gas  
supply.  
PAGE 17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
WIRING DIAGRAMS  
GAS CONTROL AND SAFETY SYSTEM WIRING DIAGRAM  
CAUTION: Label all wiring prior to disconnection when servicing controls. Wiring errors can cause improper and dan-  
gerous operation. Verify proper operation after servicing.  
The gas control wiring diagram shown here should be used by service technicians for guidance when troubleshooting  
problems with the pilot safety (millivolt) system or burner remote control system or when locating system components for  
repair / replacement. Note: If replacement of any of the original wire is necessary, use 105°C thermoplastic wiring.  
GAS CONTROL WIRING DIAGRAM  
CIRCULATING BLOWER WIRING DIAGRAM  
PAGE 18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TROUBLESHOOTING Qualified Technicians Only  
PROBLEM  
CAUSE(S)  
SOLUTIONS  
1) Pilot will not light, and Piezo Igniter does a. Electrode wire (at Piezo Igniter) not Make sure connections are solid.  
not produce a heavy blue spark.  
pushed completely on.  
b. Piezo igniter is defective  
Replace piezo igniter.  
2) Pilot will not light, but Piezo Igniter pro- a. Incorrect lighting procedure.  
Carefully follow the lighting / operating  
instructions found in the appliance of this  
owner's manual.  
Check for multiple gas shut-offs; check  
gas supply lines.  
duces a heavy blue spark.  
3) Pilot will not stay lit.  
b. No gas to appliance due to shut valves or  
disconnected gas lines.  
a. Thermocouple is not firmly connected to Ensure thermocouple is fully inserted into  
control valve. pilot assembly.  
b. Pilot flame is not directed to top of ther- Replace thermocouple.  
mocouple.  
c. Thermocouple is defective. Make sure  
connection is solid.  
4) Pilot flame stays lit, but main burner will a. Burner control switch (on control panel) is Position the burner control switch to  
not light.  
in "OFF" position; or thermostat (if in-  
stalled) is turned off or temperature set-  
ting is too low.  
"ON"; or adjust the thermostat. Refer to  
manufacturer's instructions for thermo-  
stat.  
b. Electrical wiring is damaged or poorly Refer to Control and Safety Wiring Dia-  
connected  
gram (page 18) and check electrical  
connections.  
c. One of the following components may be  
defective: burner control switch, thermo- Refer to Control and Safety Systems  
stat, vent spill switch, or thermopile.  
Wiring Diagram (page 18). Electrically  
bypass components one at a time and  
replace defective item.  
5) Main burner stays lit for up to 10 minutes a. Vent is blocked; flue gas is "spilling", Examine venting system for blockage.  
and then shuts off, pilot flame remains lit.  
which activates the spill switch and shuts  
down the appliance.  
b. The house is negatively pressurized re-  
sulting in spill switch activation.  
Remove any blockage.  
Open a window to see if the problem is  
corrected.  
6) Smell of gas  
a. Loose fittings may be allowing gas to leak Check all joints for leakage: pilot assem-  
out.  
bly, gas supply system, main burner as-  
sembly, pilot and burner adjustment  
screws. Use a proper leak check solu-  
tion. WARNING: Never use an open  
flame to check for leaks.  
7) A thin coating of black soot forms on the a. Burner primary air inlet is restricted or Be sure all openings (fresh air inlets) in  
window. NOTE: See page 16, Cleaning  
Glass.  
blocked.  
stove are free from dust and debris. Re-  
check these areas periodically.  
Make sure ceramic logs are in their cor-  
rect positions.  
b. Flames make contact with logs or other  
surfaces.  
c. Improper venting.  
Check for flue blockage, disconnected  
flue, improper installation. Make appro-  
priate corrections.  
8) A white coating forms on windows, logs, a. Residues / impurities being burned off.  
and / or inside walls of firebox.  
Follow cleaning guidelines outlined in the  
MAINTENANCE section of this manual.  
9) Circulation blower makes a humming a. Impeller blades in circulation blower are Disconnect electrical power to circulation  
sound, but there is no circulation air.  
dirty.  
blower, access blower and clean impeller  
blades as outlined in the MAINTE-  
NANCE section of this manual.  
Replace blower.  
b. Circulation blower is defective.  
REFERENCE INFORMATION FOR QUALIFIED TECHNICIAN:  
Thermopile / Thermocouple Operation  
Thermopile: Millivolt production should be a minimum of  
325 MV with pilot only.  
Drop out rate  
TP 50-60 MV  
TP 1 1/2-2 Min. (3 max.) if longer, replace thermopile.  
Thermocouple: Millivolt production should be a minimum of  
14 MV with pilot only.  
PAGE 19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
REPLACEMENT PARTS  
Model L30-2 BF  
Catalog #  
Item # Description  
Catalog #  
52L12  
Item # Description  
9
Thermal Fan Switch  
1
2
3
4
5
6
Trim, Decorative  
Window Frame, Charcoal  
Burner Assembly  
Blower, Air Circulating  
Power Cord (blower)  
Rheostat w / Knob  
(speed control for blower)  
On / Off Switch, Burner  
Spill Switch  
52L04  
17M63  
17M61  
52L19  
52L17  
52L03  
10  
Control Valve NG (with LP  
Conv. Kit)  
( 0-4500’ ) Orifice, #31, NG  
64L98  
11  
11  
11  
11  
12  
13  
52L27  
( 0-4500’ ) Orifice, #50, LPG 52L08  
(4500’ ) Orifice, #32, NG  
(4500’ ) Orifice, #51, LPG  
Pilot Assembly NG  
Log Set  
52L06  
52L09  
52L15  
17M59  
7
8
52L13  
52L18  
PAGE 20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
OPTIONAL ACCESSORIES  
Item #  
Description  
Door Kit, L30 BF-2, Gold  
Brickaded Interior Kit, L30  
Deluxe Remote Control (Thermostatically controlled)  
Remote Control (Standard On / Off)  
Wall Thermostat Kit  
Catalog #  
14M09  
14M06  
98K99  
26N04  
89L36  
Model  
1
2
3
4
5
6
DK3B-G  
BRK-L30  
RC-STAT  
RC  
WTK  
TSPK-C  
Touch-up Spray Paint Kit, Charcoal  
19L92  
(3) Deluxe Remote Features  
PAGE 21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SPECIFICATIONS: Model L30 BF-2  
Top View  
Approx. Sq. Ft.  
Heating Capacity 1500 sq. ft.  
Flue Size  
4” - Top Vent  
29”  
Height Overall  
Height to Flue  
Outlet  
30 3/8”  
29 7/8”  
16 1/8”  
Width  
Depth  
Fuel  
Natural Gas (standard)  
(or) LP Gas (convertible).  
Gas inlet 3/8” NPT-Male / Flex Line  
(or) remove flex, 3/8” NPT–Female Flare.  
Side View  
Performance  
Features  
Variable Flame Control.  
High Efficiency Heat Exchanger.  
Natural Convection & Radiant Heat.  
Standing Pilot / Operates During Power  
Outages. Remote Control & Wall  
Thermostat Capable.  
Technical  
Features  
Honeywell Combination Gas Control  
Valve, Millivolt - VS8520E. Safety Shut  
Down Sensor (Spill Switch).  
Pan Burner with Tuned Ports.  
Radiant & Fan Assisted Convection  
Heat.  
Safety Test  
Tested and certified by CSA to ANSI  
standards. Z21.88 – (1998) CSA 2.33 -  
(1998). Vented Gas Fireplace Heater .  
Heat Input  
25,000 to 37,000 BTU’s (Nat. Gas)  
28,000 to 35,000 BTU’s (Propane)  
~ Square feet heating capacities are approximations only.  
They will vary depending upon level of insulation, climate,  
house design, ceiling height, ambient outside tempera-  
tures and how stove is operated.  
Ship Weight  
200 lb.’s  
Dimensions shown are approximations only (+ / - ¼”)  
SPECIFICATIONS  
GAS TYPE  
NATURAL  
GAS  
PROPANE  
(LP)  
CLEARANCES TO COMBUSTIBLES  
Orifice Size  
Minimum Supply Pressure  
#31 -.120  
4.5” WC  
#50-.070”  
10.5” WC  
Back Wall Min.  
Side Wall Min.  
2 In. / 51 mm  
12 In. / 305 mm  
Maximum Supply Pressure  
10.5” WC  
13.0” WC  
Corner (45° angle)s  
HIGH SETTING  
Manifold Pressure  
Input BTU / HR  
LOW SETTING  
Mainfold Pressure  
Input BTU / HR  
stove corner to wall, min.  
Ceiling Height Minimum  
Alcove Min. Height  
Alcove Min. width  
Alcove - Max. Depth into  
stove face to alcove opening 24 In. / 610 mm  
* With the orifice, manifold pressure and input  
ratings shown above.  
4 In. / 102 mm  
3.5” WC  
37,000  
10.0” WC  
35,000  
65 In. / 1651 mm  
65 In. / 1651 mm  
54 In. / 1372 mm  
1.8” WC  
25,000  
6.6” WC  
28,000  
Altitude - U.S.A. 0-4,500 Ft. (0-1372M) No derating  
Altitude - Canada 0-4,500 Ft. (0-1372M) No derating  
For installation higher than altitudes shown above, reorifice per Gas  
Codes.  
This Appliance is equipped at the factory for the use with Natural Gas or Propane (LP). Appliances using propane must  
be field conversed using the LP Conversion Kit supplied with appliance.  
PAGE 22  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SAFETY / LISTING LABEL: Model L30 BF-2  
PAGE 23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
OWNERSHIP RECORDS  
Dealer’s Name:  
Dealer’s Address:  
City:  
State:  
Zip Code:  
Serial Number:  
Notes:  
Date of Purchase:  
Date Installed:  
SERVICE AND MAINTENANCE LOG  
Service Service  
Date Technician  
Service  
Description  
PAGE 24  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1110 West Taft Avenue  
Orange, CA 92865  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Land Pride Lawn Mower RB 15 User Manual
Lanier Copier 1027 User Manual
Lennox Hearth Door 38ABF User Manual
Lennox Hearth Indoor Fireplace Villa Vista
Lenoxx Electronics CD Player CD 104 User Manual
LifeCore Fitness Home Gym LC 990 User Manual
Lochinvar Gas Heater USN User Manual
LST Smoke Alarm FWI2 1 User Manual
LST Smoke Alarm IBSOU DD P01 User Manual
Manitowoc Ice Ice Maker K00142 User Manual