Lennox Hearth Air Conditioner 502 User Manual

What Is the Harmony IIR Zone Control System?  
Lennox Harmony IIR Zone Control System manages the distribution of conditioned air to as many as four  
specific areas or zones in a home or small commercial building. The Harmony IIR control Is an advanced  
control system that allows a home to be zoned for heating and cooling without the extra expense of pur-  
chasing two or more HVAC (Heating, Ventilation, and Air Conditioning) systems.  
This control allows the owner to heat or cool occupied areas without conditioning unused areas, re-  
sulting in lower utility bills. This control orchestrates the system components to provide a balanced  
and comfortable environment.  
The system consists of the control panel and the control center. The Harmony II control panel is your  
link to a comfortable enviroment. The control panel is usually located near the main or master ther-  
mostat. The control center is the larger control box and is the ꢀbrains" of the Harmony IIR system. It  
organizes the operations of the thermostats, dampers, and HVAC equipment to result in total com-  
fort. The Harmony IIR system operates with any of the following HVAC system combinations: Option  
1 − Pulse21TM ꢀV" series gas furnace and either a single− or two− speed condensing unit; Option 2 −  
CB21 series blower coil unit and either a Lennox single− or two− speed heat pump; or Option 3 −  
Pulse21 ꢀV" series gas furnace, a Lennox heat pump, and the FM21 control. Harmony IIR zone con-  
trol system uses off−the−shelf thermostats and dampers with any of the above systems to distribute  
conditioned air to zones.  
How Are Zones Determined?  
Your Lennox dealer has sectioned the rooms of your home or building into zones using the below  
considerations.  
Structural/Architectural Considerations  
In multi−level houses using regular HVAC systems, heated air rises to the upper floor(s) causing those  
rooms become too hot. Zoning will remedy this situation by splitting the conditioned space into two  
specific zones (first and second floors). The second floor temperature is now controlled by its own ther-  
mostat, not that of the first floor.  
Climate Considerations  
Exposure from the sun and weather can produce cold and hot spots in homes that are conditioned  
with the use of one thermostat. Zoning lessens this by grouping rooms with the same exposure into  
one zone. Therefore, a room with a northern exposure and a room with a southern exposure should  
not be zoned together. In the winter, the northern room may be too cool while the southern room may  
be too hot. In order to keep a balance of conditioned air, the zone must contain rooms with the same  
weather exposure.  
Occupancy Considerations  
A single structure contains different types of living spaces. Without zoning, it is difficult to condition all  
areas so that everyone will be comfortable. Zoning a home or office allows the owner to control the  
zones which need to be conditioned. Rooms that are used or occupied at the same time are zoned to-  
gether. Bedrooms which are generally used at night, should not zoned with a living room that is used only  
during the day or evening.  
502,862M  
02/2000  
®
Harmony II User’s Manual  
Page 1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
To Operate Harmony II® control:  
Choose either Central or Zone mode.  
Central Mode: Heating and cooling to all zones.  
1− Press Central button on control panel.  
2− Choose either Heat or Cool or Auto button on control panel.  
3− Choose either Fan Auto or Fan On button on control panel. The Fan switch on all thermostats  
will be inoperable. The fan is controlled at the control panel.  
4− Set the zone 1 master thermostat at the same position (HEAT or COOL or AUTO) as the control  
panel. If your thermostat system does not have an auto−changeover selection, set the control  
panel in AUTO and the zone 1 thermostat in either HEAT or COOL. (Do not adjust other zone  
thermostats since they are non−functional in Central mode.)  
5− Set thermostat to desired room temperature.  
Zone Mode: Heating and cooling to specific zones.  
1− Press Zone button on control panel.  
2− Choose either Heat or Cool or Auto button on control panel.  
3− Choose either Fan Auto or Fan On button on control panel. The Fan switch on all thermostat will  
be inoperable. The fan is controlled at the control panel.  
4− Set each zone thermostat at the same position (HEAT or COOL or AUTO) as the control panel.  
If your thermostats do not have an auto−changeover selection, set the control panel in AUTO  
and the zone thermostats in either HEAT or COOL.  
5− Set thermostats to desired room temperature.  
Harmony II® Control Panel  
Press Central for all zones  
to be conditioned at the  
same time.  
Press Zone for specific zones to  
receive conditioned air upon  
each zone’s need.  
Press Cool to allow cooling only.  
For Central mode, Zone 1 thermo-  
stat should also be set at Cool. For  
Zone mode, all thermostats should  
also be set at Cool.  
System Off button turns  
off Harmony II control.  
Press Heat to allow heating only.  
For Central mode, Zone 1 thermo-  
stat should also be set at Heat. For  
Zone mode, all thermostats should  
also be set at Heat.  
Press Auto to allow either cooling or  
heating, depending on the need. For  
Central mode, Zone 1 thermostat  
should also be set at Auto. For Zone  
mode, all thermostats should also be  
set at Auto. If your thermostats are  
not equipped with an Auto setting,  
place control panel in Auto and ther-  
mostats in either Heat or Cool.  
Red service light flashes from be-  
hind the control panel cover when  
system requires service. Error  
codes will be stored in control  
center for readout by technician  
only.  
Harmony II  
Press Fan Auto to allow blower to run only while system is  
supplying conditioned air. The blower will cycle on and off  
according to the demand for heating or cooling. By cycling on  
and off, air from different zones is not mixed and better effi-  
ciencies are achieved.  
Press Fan On to allow blower to run continuously to circulate air. The  
fan will keep running in this mode until the Fan Auto button is  
pressed. Fan On tends to mix the air from different zones and effi-  
ciency may suffer if Fan On option is used on a regular basis.  
Page 3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
®
Harmony II Zone Control System  
Zone # Rooms  
1
2
3
4
Record which rooms are zoned together.  
Lennox Dealer:  
Contact:  
Telephone Number:  
Installation Date:  
Page 4  
Download from Www.Somanuals.com. All Manuals Search And Download.  

KTI Networks Cable Box KCD 302 User Manual
La Crosse Technology Portable Radio WS 7159U User Manual
LG Electronics Washer F1443KD User Manual
Life Fitness Elliptical Trainer SX30 User Manual
Linksys Network Router WRT54G3G VN User Manual
Magic Chef Convection Oven MCSGC12W User Manual
Maxi Cosi Car Seat THE SAFE WORLD OF I User Manual
Maytag Clothes Dryer MEDZ600TB2 User Manual
McCulloch Chainsaw 41BY44NQ077 User Manual
Melissa Fan 271 002 User Manual