Leica Stud Sensor 760498a User Manual

TM  
Leica DISTO D3  
The original laser distance meter  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1
2
3
5
4
6
7
8
9
11  
10  
19  
13 15  
11  
16,17,18  
12 14  
10  
20  
1
2
4
MENU  
21  
22  
23  
UNIT RESET  
TRIPOD  
BEEP ONOFF  
TIMER  
a
?
3
27  
5
max  
a
b
b
24  
28  
25  
29  
26  
b
6
min  
7,8,9  
30  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
EN  
F
User Manual  
Safety Instructions  
Symbols used  
English  
E
The symbols used in the Safety Instructions have the  
following meanings:  
Congratulations on the purchase of your  
Leica DISTO™ D3 .  
P
WARNING:  
Indicates a potentially hazardous situation or  
an unintended use which, if not avoided, will result in  
death or serious injury.  
Carefully read the Safety Instruc-  
ƽ
tions and the User Manual before  
using this product.  
The person responsible for the instrument must  
ensure that all users understand these directions and  
CAUTION:  
ƽ
Indicates a potentially hazardous situation or  
an unintended use which, if not avoided, may result  
in minor injury and/or in appreciable material, finan-  
cial and environmental damage.  
Safety Instructions .............................................1  
Start-up................................................................5  
Menu functions...................................................7  
Operation.............................................................8  
Measuring ............................................................9  
Functions...........................................................10  
Appendix............................................................15  
Important paragraphs which must be adhered  
to in practice as they enabled the product to be used  
in a technically correct and efficient manner.  
)
Use of the instrument  
Permitted use  
Measuring distances  
Computing functions, e. g. areas and volumes  
Measuring tilts  
Prohibited use  
Using the instrument without instruction  
Using outside the stated limits  
Deactivation of safety systems and removal of  
explanatory and hazard labels  
Leica DISTO™ D3 760498a en  
1
Safety Instructions  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Opening of the equipment by using tools (screw-  
drivers, etc.), as far as not specifically permitted  
for certain cases  
Carrying out modification or conversion of the  
product  
Use after misappropriation  
Use of accessories from other manufacturers  
without the express approval of Leica Geosys-  
tems.  
Deliberate or irresponsible behaviour on scaf-  
folding, when using ladders, when measuring  
near machines which are running, or near parts of  
machines or installations which are unprotected  
Aiming directly into the sun  
Deliberate dazzling of third parties; also in the  
dark  
EN  
F
Areas of responsibility  
Responsibilities of the manufacturer of the orig-  
inal equipment Leica Geosystems AG, CH-9435  
Heerbrugg (for short Leica Geosystems):  
Leica Geosystems is responsible for supplying the  
product, including the User Manual and original  
accessories, in a completely safe condition. (addi-  
tional language versions can be found at:  
E
P
Responsibilities of the manufacturer of non-  
Leica accessories:  
The manufacturers of non-Leica accessories  
)
for the Leica DISTO™ are responsible for developing,  
implementing and communicating safety concepts for  
their products. They are also responsible for the  
effectiviness of these safety concepts in combination  
with the Leica Geosystems equipment.  
Inadequate safeguards at the surveying site (e.g.  
when measuring on roads, construction sites,  
etc.)  
Limits of use  
Responsibilities of the person in charge of the  
instrument:  
See section “Technical Data“.  
)
WARNING  
The person responsible for the instrument  
ƽ
The Leica DISTO™ is designed for use in areas perma-  
nently habitable by humans, do not use the product  
in explosion hazardous areas or in aggressive envi-  
ronments.  
must ensure that the equipment is used in accor-  
dance with the instructions. This person is also  
accountable for the deployment of personnel and for  
their training and for the safety of the equipment  
when in use.  
The person in charge of the instrument has the  
following duties:  
Leica DISTO™ D3 760498a en  
2
Safety Instructions  
Download from Www.Somanuals.com. All Manuals Search And Download.  
To understand the safety instructions on the  
product and the instructions in the User Manual.  
To be familiar with local safety regulations  
relating to accident prevention.  
WARNING:  
Flat batteries must not be disposed of with  
household waste. Care for the environment and take  
them to the collection points provided in accordance  
with national or local regulations.  
EN  
F
ƽ
E
To inform Leica Geosystems immediately if the  
equipment becomes unsafe.  
The product must not be disposed of with  
household waste.  
Dispose of the product appropriately in  
accordance with the national regulations in  
force in your country.  
Always prevent access to the product by  
unauthorized personnel.  
P
Hazards in use  
CAUTION:  
ƽ
Watch out for erroneous distance measure-  
ments if the instrument is defective or if it has been  
dropped or has been misused or modified.  
Product specific treatment and waste  
management information can be downloaded from  
the Leica Geosystems home page at  
Precautions:  
Carry out periodic test measurements. Particularly  
after the instrument has been subject to abnormal  
use, and before, during and after important measure- http://www.leica-geosystems.com/treatment or  
ments.  
received from your Leica Geosystems dealer.  
Make sure the Leica DISTO™ optics is kept clean and  
Electromagnetic Compatibility  
(EMC)  
that there is no mechanical damage to the bumpers.  
CAUTION:  
ƽ
The term "electromagnetic compatibility" is taken to  
mean the capability of the product to function  
smoothly in an environment where electromagnetic  
radiation and electrostatic discharges are present,  
and without causing electromagnetic interference to  
other equipment.  
In using the instrument for distance measure-  
ments or for positioning moving objects (e.g. cranes,  
building equipment, platforms, etc.) unforeseen  
events may cause erroneous measurements.  
Precautions:  
Only use this product as a measuring sensor, not as  
a control device. Your system must be configured and  
operated in such a way, that in case of an erroneous  
measurement, malfunction of the device or power  
failure due to installed safety measures (e.g. safety  
limit switch), it is assured that no damage will occur.  
WARNING:  
ƽ
The Leica DISTO™ conforms to the most strin-  
gent requirements of the relevant standards and  
regulations. Yet, the possibility of it causing interfer-  
ence in other devices cannot be totally excluded.  
Leica DISTO™ D3 760498a en  
3
Safety Instructions  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CAUTION:  
WARNING:  
Changes or modifications not expressly  
approved by Leica Geosystems for compliance could  
void the user’s authority to operate the equipment.  
EN  
F
ƽ
ƽ
Never attempt to repair the product yourself. In  
case of damage, contact the local dealership.  
E
FCC statement (applic. in U.S.)  
Laser classification  
Integrated distancemeter  
The Leica DISTO™ produces a visible laser beam  
which emerges from the front of the instrument.  
It is a Class 2 laser product in accordance with:  
This equipment has been tested and found to comply  
with the limits for a Class B digital device, pursuant to  
part 15 of the FCC Rules. These limits are designed to  
provide reasonable protection against harmful inter-  
ference in a residential installation.  
P
This equipment generates, uses and can radiate radio  
frequency energy and, if not installed and used in  
accordance with the instructions, may cause harmful  
interference to radio communications.  
However, there is no guarantee that interference will  
not occur in a particular installation.  
If this equipment does cause harmful interference to  
radio or television reception, which can be deter-  
mined by turning the equipment off and on, the user  
is encouraged to try to correct the interference by  
one or more of the following measures:  
IEC60825-1 : 2007 "Radiation safety of laser  
products"  
Laser Class 2 products:  
Do not stare into the laser beam or direct it towards  
other people unnecessarily. Eye protection is  
normally afforded by aversion responses including  
the blink reflex.  
WARNING:  
ƽ
Looking directly into the beam with optical aids  
(e.g. binoculars, telescopes) can be hazardous.  
Reorient or relocate the receiving antenna.  
Increase the separation between the equipment  
and receiver.  
Connect the equipment into an outlet on a circuit  
different from that to which the receiver is  
connected.  
Consult the dealer or an experienced radio/TV  
technician for help  
Precautions:  
Do not look directly into the beam with optical aids.  
CAUTION:  
ƽ
Looking into the laser beam may be hazardous  
to the eyes.  
Precautions:  
Do not look into the laser beam. Make sure the laser  
is aimed above or below eye level. (particularly with  
fixed installations, in machines, etc.)  
Leica DISTO™ D3 760498a en  
4
Safety Instructions  
Download from Www.Somanuals.com. All Manuals Search And Download.  
EN  
F
Labelling  
Start-up  
Inserting/replacing batteries  
Laser Radiation  
E
See figure {A}  
Do not stare into the beam  
Laser class 2  
1
Remove battery compartment lid and attach  
handstrap.  
Insert batteries, observing correct polarity.  
Close the battery compartment again. Replace  
P
acc. IEC 60825-1:2007  
Maximum radiant power:  
<1mW  
Emitted wavelength:  
620-690nm  
2
3
Beam divergence: 0.16 x 0.6 mrad  
-9  
Pulse duration:  
1 x 10  
s
the batteries when the symbol  
nently in the display.  
flashes perma-  
Use alkaline batteries only.  
)
Remove the batteries before any long period  
of non-use to avoid the danger of corrosion.  
)
Multifunctional endpiece  
See figure {B}  
Position of the product label see last page!  
The instrument can be adapted for the following  
measuring situations:  
For measurements from an edge, fold out the  
positioning bracket until it first locks in place. See  
figure {C}.  
For measurements from a corner, open the posi-  
tioning bracket until it locks in place, then push  
the positioning bracket lightly to the right to fold  
it out fully. See figure {D}.  
Leica DISTO™ D3 760498a en  
Download from Www.Somanuals.com. All Manuals Search And Download.  
5
Start-up  
 
A built-in sensor automatically detects the orienta-  
tion of the positioning bracket and adjusts the zero  
point of the instrument accordingly.  
11 Save constant value, call up constant value  
12 Historical memory, call up values  
13 Battery status  
EN  
F
14 Timer  
E
15 Area/volume  
16 Tilt  
17 Horizontal distance measurement using tilt  
18 Room corner angle function  
19 Menu  
20 Continuous laser  
21 Reset  
22 Reference (tripod)  
23 Beep  
24 Circumference  
25 Wall area  
26 Ceiling area  
Keypad  
P
See figure {E}:  
1
2
3
4
5
6
7
8
9
ON / DIST (On/measuring) button  
Plus (+) button  
Minus (-) button  
Area / volume button  
Indirect measurement (Pythagoras) button  
Reference button  
Functions button  
Timer button  
Storage button  
10 Menu/equal button  
11 Clear/off button  
27 Intermediate line 1  
28 Intermediate line 2  
29 Intermediate line 3  
30 Summary line  
Display  
See figure {F}  
1
2
3
4
5
6
7
8
9
Laser active  
Reference (front)  
Reference (rear)  
Reference (corner stop)  
Measuring with the tripod  
Stake out function  
Single Pythagorean measurement  
Double Pythagorean measurement  
Double (partial height) measurement  
10 Illumination  
Leica DISTO™ D3 760498a en  
6
Start-up  
Download from Www.Somanuals.com. All Manuals Search And Download.  
EN  
F
Setting the unit for distance mea-  
Menu functions  
surements  
Settings  
The following units can be set:  
E
The menu allows settings to be altered and perma-  
nently stored. After switching off the device or  
replacing the batteries the settings are stored.  
Distance  
Area  
Volume  
0.000 m³  
P
0.000 m²  
0.000 m²  
0.000 m²  
0.00 ft²  
0.00 ft²  
0.00 ft²  
0.00 ft²  
0.00 ft²  
0.00 ft²  
0.00 ft²  
0.00 ft²  
1.  
2.  
3.  
4.  
5.  
6.  
7.  
8.  
0.000 m  
0.0000 m  
0.00 m  
0.000 m³  
0.000 m³  
0.00 ft³  
0.00 ft³  
0.00 ft³  
0.00 ft³  
0.00 ft³  
0.00 ft³  
0.00 ft³  
0.00 ft³  
Navigation in the menu  
0.00 ft  
The menu allows settings to be made at the user  
level. The instrument can be specifically configured to  
your personal requirements.  
0'00'' 1/32  
0'00'' 1/16  
0'00'' 1/8  
0.0 in  
General description  
button (pressed long) brings up the  
, the  
9.  
10.  
11.  
0 1/32 in  
0 1/16 in  
0 1/8 in  
MENU  
set units and the  
symbol are displayed.  
button (pressed short) pages through each  
menu item. See figure {G}.  
Setting the unit for tilt measure-  
or  
button (pressed short) brings up the next menu  
item.  
A long press on the  
the new settings made in the submenu items .  
Pressing the button for longer in the menu  
button to make changes in menu items.  
ments  
The following units can be set for tilt measurements:  
Units for tilt  
button in the menu confirms  
1.  
2.  
+/- 0.0°  
0.00%  
Beep (BEEP  
)
allows you to quit the settings function without  
saving.  
You can switch the beep on or off.  
Leica DISTO™ D3 760498a en  
7
Menu functions  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
A reset returns the following values to their factory  
settings:  
EN  
F
Continuous laser (  
)
You can switch the continuous laser function on or  
off.  
Reference (rear)  
Display illumination (ON)  
Beep (ON)  
Unit (m(mm))  
Stack and memory are erased  
E
With the continuous laser function set on, each press  
P
of the  
button triggers a measurement. The laser  
automatically switches off after 15 minutes.  
All customised settings and stored values are  
also lost.  
Measuring with the tripod ( TRIPOD  
)
)
The reference must be appropriately adjusted in  
order to be able to take correct measurements with  
a tripod. To do this select the TRIPOD symbol in this  
menu item. You can switch the reference on the  
tripod on or off. The setting can be seen on the  
Operation  
Switching on and off  
display  
.
Switches on the instrument and laser. The  
display shows the battery symbol until the  
next button is pressed.  
Pressing this button for longer switches the  
instrument off.  
The instrument switches off automatically  
after 6 minutes of inactivity.  
Display - keypad illumination ( )  
Automatic illumination of the display and the keypad  
can be switched on or off.  
Reset - returning the instrument to CLEAR button  
the factory settings (  
)
The last action is cancelled. While making area or  
volume measurements, each single measurement can  
be deleted and remeasured in series.  
The instrument has a RESET function. When you  
select the menu function RESET and confirm, the  
instrument defaults to the factory settings.  
Leica DISTO™ D3 760498a en  
8
Operation  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
EN  
F
Display / keypad illumination  
The instrument has a sensor that automatically  
switches the display and keypad illumination on or off  
in response to lighting conditions.  
Measuring  
Single distance measurement  
E
Press to activate the laser. Press again to trigger  
the distance measurement.  
P
Reference setting  
The result is displayed immediately.  
The default reference setting is from the rear of the  
instrument.  
Minimum/maximum measurement  
This function allows the user to measure the  
minimum or maximum distance from a fixed  
measuring point. It can also be used as to determine  
spacings. See figure {I}  
Press this button to take the next measurement  
from the front edge  
. A special beep sounds when-  
ever the reference setting is changed.  
After a measurement the reference returns automat-  
ically to the default setting (rear reference). See  
figure {H}.  
It is commonly used to measure room diagonals  
(maximum values) or horizontal distances (minimum  
values).  
Press this button for longer the front reference  
Press and hold down this button until you hear  
a beep. Then slowly sweep the laser back and forth  
and up and down over the desired target point - (e.g.  
into the corner of a room).  
is set permanently.  
Press this button, the rear reference is set again.  
Press to stop continuous measurement. The  
values for maximum and minimum distances are  
shown in the display as well as the last measured  
value in the summary line.  
Leica DISTO™ D3 760498a en  
Download from Www.Somanuals.com. All Manuals Search And Download.  
9
Measuring  
   
appears in the display.  
EN  
F
Functions  
Press this button to take the first length  
measurement (e.g. length).  
Addition / subtraction  
E
Distance measuring.  
Press this button to take the second length  
measurement (e.g. width).  
The next measurement is added to the previous  
one.  
P
Press this button to take the third length  
measurement (e.g. height). The value is shown in the  
second line.  
The next measurement is subtracted from the  
previous one.  
The volume then appears in the summary line.  
This process can be repeated as required. The result  
is always shown in the summary line with the  
previous value in the second line.  
Press the  
button for longer to display additional  
room information such as ceiling/floor area, surface  
area of the walls, circumference.  
The last step is cancelled.  
Tilt measurement  
Area  
Press once. The  
symbol appears in the  
The inclination sensor measures tilts between  
)
)
display.  
45°.  
Press this button to take the first length  
measurement (e.g. length).  
During tilt measurement the instrument  
should be hold without a transverse tilt ( 10°).  
Press this button once to activate the tilt  
Press it again to take the second length  
measurement (e.g. width).  
sensor. The  
symbol appears in the display. The  
tilt is continuously shown as ° or % depending on the  
setting.  
The result is displayed in the summary line.  
Press the  
circumference.  
button for longer to calculate the  
Press to measure the inclination and the  
distance. See figure {J}.  
Volume  
Press this button twice. The  
symbol  
Leica DISTO™ D3 760498a en  
10  
Functions  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
EN  
F
Direct horizontal distance  
Stake out function  
Two different distances (a and b) can be entered into  
the instrument and can then be used to mark off  
defined measured lengths, e.g. in the construction of  
wooden frames.  
Press this button twice and the following  
symbol appears in the display  
.
E
P
Press this button to measure tilt and distance.  
The summary line displays the result as the direct  
horizontal distance.  
See figure {L}.  
Entering stake out distances:  
Press this button four times and the stake out  
Room corner angle function  
The angles in a triangle can be calculated by  
measuring the three sides. This function can be used  
e. g. to check a right-angled room corner. See figure  
{K}.  
a
function symbol appears in the display  
.
b
b
The value (a) and the corresponding intermediate line  
flash.  
By using  
and  
, you can adjust the values  
Press this button three times and the room  
(first a and then b) to suit the desired stake out  
distances. Holding the buttons down increases the  
rate of change of the values.  
corner symbol appears in the display  
.
Mark the reference points to the right and left (d1/  
d2) of the angle to be measured.  
Once the desired value (a) has been reached it can be  
confirmed with the  
button.  
Press this button to measure the first (short)  
side of the triangle (d1 or d2).  
The value (b) and the intermediate line flashes (the  
defined value (a) is automatically adopted). Value (b)  
can be entered using  
Press this button to measure the second (short)  
side of the triangle (d1 or d2).  
and  
.
The defined value (b) is confirmed with the  
button.  
Press this button to measure the third (long)  
side of the triangle (d3).  
Pressing the  
button starts the laser measure-  
The result is displayed in the summary line as the  
room corner angle.  
ment. The display shows required stake out distance  
Leica DISTO™ D3 760498a en  
11  
Functions  
Download from Www.Somanuals.com. All Manuals Search And Download.  
in the summary line between the stake out point  
(first a and then b) and the instrument (rear refer-  
ence).  
positioning bracket fully folded out and the  
instrument placed on a wall).  
EN  
F
The minimum/maximum function can be used -  
see explanation in "Measuring -> Minimum/  
maximum measurement". The minimum value  
must be used for measurements at right angles to  
the target; the maximum distance for all other  
measurements.  
If the DISTO™ is then moved slowly along the stake  
out line the displayed distance decreases. The instru-  
ment starts to beep at a distance of 0.1m from the  
E
P
next stake out point.  
a
b
b
distance to be measured are at right angles. Use the  
Minimum/maximum function, as explained in  
"Measuring -> Minimum/maximum measurement".  
The arrows in the display  
indicate in which direc-  
)
tion the DISTO™ needs to be moved in order to  
achieve the defined distance (either a or b). As soon  
as the stake out point is reached the beep changes  
and the intermediate line starts to flash.  
Indirect measurement - determining a dis-  
tance using 2 auxilliary measurements  
The function can be stopped at any time by pressing  
the  
button.  
See figure {M}  
e.g. for measuring building heights or widths. It is  
helpful to use a tripod when measuring heights that  
require the measurement of two or three measure-  
ments.  
Indirect measurement  
The instrument can calculate distances using Pythag-  
oras’ theorem.  
This method is especially helpful if the distance to be  
measured is difficult to reach.  
Press this button once, the display shows  
.
The laser is switched on.  
Make sure you adhere to the prescribed  
sequence of measurement:  
Aim at the upper point (1) and trigger the  
)
measurement. After the first measurement the value  
is adopted. Keep the instrument as horizontal as  
possible.  
All target points must be in a horizontal or vertical  
plane.  
The best results are achieved when the instru-  
ment is rotated about a fixed point (e.g. with the  
Press and hold down this button to trigger  
Leica DISTO™ D3 760498a en  
12  
Functions  
Download from Www.Somanuals.com. All Manuals Search And Download.  
continuous measurement, sweep the laser back and  
forth and up and down over the ideal target point.  
Indirect measurement - determining a chain  
value using 3 measurements  
EN  
F
Press to stop continuous measurement (2). The  
result is displayed in the summary line, the partial  
results in the secondary line.  
See figure {O}  
E
e.g. determining the height between point 1 and  
point 2 using three target points.  
P
Press this button three times ; the display  
Indirect Measurement - determining a dis-  
tance using 3 measurements  
shows the following symbol  
switched on.  
. The laser is  
See figure {N}  
Aim at the upper point (1).  
Press this button twice; the display shows the  
Press this button and trigger the measurement.  
After the first measurement the value is adopted. The  
display flashes (2).  
following symbol  
. The laser is switched on.  
Aim at the upper point (1) and trigger the  
measurement. After the first measurement the value  
is adopted. Keep the instrument as horizontal as  
possible  
Triggers the measurement. After the second  
measurement the value is adopted. The display  
flashes (3).  
Press and hold down this button to trigger  
continuous measurement, sweep the laser back and  
forth and up and down over the ideal target point.  
Press and hold down this button to trigger  
continuous measurement. Sweep the laser back and  
forth and up and down over the ideal target point.  
Press to stop continuous measurement (2). The  
value is adopted. Aim at the lower point and  
Press this button to end continuous measure-  
ment. The result is displayed in the summary line, the  
partial results in the secondary lines.  
Press this button to trigger the measurement  
(3). The result is displayed in the summary line, the  
partial results in the secondary lines.  
Leica DISTO™ D3 760498a en  
13  
Functions  
Download from Www.Somanuals.com. All Manuals Search And Download.  
EN  
F
Storage of constants/historical  
storage  
Timer (self-triggering)  
Press this button to set a 5-second time delay.  
or  
E
Storage of a constant  
Press and hold down this button until the  
desired time delay is reached (max. 60 seconds).  
You can store and recall a frequently used value e.g.  
height of a room. Measure the desired distance,  
P
Once the key is released the remaining seconds until  
measurement (e.g. 59, 58, 57...) are displayed in a  
countdown. The last 5 seconds are counted down  
with a beep. After the last beep the measurement is  
taken and the value is displayed.  
press and hold the  
to confirm storage.  
button until the device beeps  
Recalling the constant  
Press this button once to recall the constant  
and make it available for further calculations by  
The timer can be used for all measurements.  
)
pressing button  
.
Historical storage  
Press this button twice and the previous 20  
results (measurements or calculated results) are  
shown in reverse order.  
The  
and  
Press this button to use a result from the  
summary line for further calculations.  
Pressing the and buttons at the same time  
buttons can be used for navigation.  
erases all the values in historical storage.  
Leica DISTO™ D3 760498a en  
14  
Functions  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Error  
Cause  
Remedy  
EN  
F
Appendix  
Error Hardware error  
Switch on/off the  
device several times. If  
the symbol still  
Message codes  
E
appears, then your  
instrument is defective.  
Please call your dealer  
for assistance.  
All message codes are displayed with either  
"Error". The following errors can be corrected:  
or  
P
Cause  
Remedy  
Technical data  
156  
160  
Transverse tilt  
Hold the instrument  
without any transverse  
tilt  
greater than 10°  
Distance  
measurements:  
Measuring accuracy  
up to 30 m  
typically:  
1.5 mm*  
1/16 ’’*  
Main tilt direction,  
angle too high  
(> 45°)  
Measure angle up to  
max. 45°  
(2 σ, standard deviation)  
204  
252  
Calculation error  
Repeat procedure  
Power Range  
Temperature too  
Cool down instrument  
Technology™:  
0.05 m to 100 m  
high  
Range (use target plate  
from about 80m)  
253  
255  
Temperature too  
low  
Warm up instrument  
Smallest unit displayed  
Distance measurement  
Minimum/maximum  
measurement, Continuous  
measurement  
0.1 mm  
Receiver signal too Use target plate  
9
weak, measurement  
time too long,  
9
distance > 100 m  
256  
257  
Received signal too Target too reflective  
Area/volume calculation of  
strong  
(use target plate)  
9
9
9
room data  
Wrong measure-  
Darkentarget(measure  
Addition / subtraction  
ment, background  
in different lighting  
brightness too high conditions)  
Indirect measurement  
260  
Laser beam inter-  
Repeat measurement  
using Pythagoras  
rupted  
Leica DISTO™ D3 760498a en  
Download from Www.Somanuals.com. All Manuals Search And Download.  
15  
Appendix  
 
Tilt measurements:  
Tilt sensor:  
Dimensions  
Weight (with batteries)  
125 x 45 x 25 mm  
110 g  
EN  
F
Accuracy  
Temperature range:  
(2 σ, standard deviation)  
Storage  
-25°C up to +70°C  
(13°F up to +158°F)  
-10°C up to +50°C  
(14°F up to +122°F)  
- to laser beam  
- to the housing  
0.3°  
0.3°  
E
Operation  
Indirect measurement  
using tilt sensor (direct  
horizontal distance)  
P
9
9
* maximum deviation occurs under unfavourable conditions such  
as bright sunlight or when measuring to poorly reflecting or very  
rough surfaces. Measuring accuracy may deteriorate by approx.  
0.1 mm/m for distances above 30 m.  
Angle measurement using  
tilt sensor( 45°)  
General:  
Laser class  
II  
Measuring conditions  
Laser type  
635 nm, < 1 mW  
Ø laser point  
6 / 30 / 60 mm  
Measuring range  
(at distances)  
(10 / 50 / 100 m)  
The range is limited to 100 m.  
Autom. laser switch-off  
after 3 min  
At night or dusk and if the target is in shadow the  
measuring range without target plate is increased.  
Use a target plate to increase the measurement  
range during daylight or if the target has poor reflec-  
tion properties.  
Autom. instrument switch-  
after 6 min  
off  
Display illumination  
Keypad illumination  
Multifunctional endpiece  
Timer (self-triggering)  
Save constant value  
9
9
9
9
9
Target surfaces  
Historical storage  
Measuring errors can occur when measuring toward  
colourless liquids (e.g. water) or dust free glass,  
Styrofoam or similar semi-permeable surfaces.  
9
(20 values)  
Tripod thread  
9
Battery life,  
up to  
Type AAA, 2 x 1.5V  
5 000 measurements  
Aiming at high gloss surfaces may deflect the laser  
beam and lead to measurement errors.  
Protection against  
IP 54, dust-proof,  
splashes and dust  
splash-proof  
Leica DISTO™ D3 760498a en  
16  
Appendix  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Against non-reflective and dark surfaces the  
measuring time may increase.  
EN  
F
Care  
E
Do not immerse the instrument in water. Wipe off dirt  
with a damp, soft cloth. Do not use aggressive  
cleaning agents or solutions. Handle the instrument  
as you would a telescope or camera.  
P
Warranty  
The Leica DISTO™ D3 comes with a three* year  
warranty from Leica Geosystems AG.  
More detailed information can be found at:  
All illustrations, descriptions and technical specifica-  
tions may be subject to change without prior notice.  
* To receive the three year warranty, the product must be regis-  
tered on our website www.disto.com within eight weeks of the  
purchase date. If the product is not registered, a two year  
warranty applies.  
Leica DISTO™ D3 760498a en  
17  
Appendix  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1
7
2
EXIT  
6
3
1
2
3
4
5
max.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Leica DISTO™ D3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Leica Geosystems AG, Heerbrugg, Switzerland has been certified as being equipped  
with a quality system which meets the International Standards of Quality  
Management and Quality Systems (ISO standard 9001) and Environmental  
Management Systems (ISO standard 14001).  
Total Quality Management - Our commitment to total customer satisfaction. Ask  
your local Leica Geosystems agent for more information about our TQM program.  
Printed in Switzerland - Copyright Leica Geosystems AG, Heerbrugg,  
Switzerland 2007  
Translation of original text (760150)  
Pat. No.: WO 9427164, WO 9818019, WO 0244754, WO 0216964,  
US 5949531, EP 1195617, US 7030969, WO 03104748  
Leica Geosystems AG  
CH-9435 Heerbrugg  
(Switzerland)  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Kyocera Printer KM 3050 User Manual
Land Pride Power Screwdriver DT55 User Manual
Lexmark All in One Printer X782 User Manual
LG Electronics DVD Player XBV613 User Manual
Magellan GPS Receiver 980 0019 001 User Manual
Magnavox CD Player FW 754P User Manual
Magnavox Portable Radio AE 6360 User Manual
Marantz Computer Monitor PD4240D User Manual
Mercury Automobile Parts D73L D TRONIC User Manual
Metabo Impact Driver Impact Drill User Manual