Extinguishing Control Panel
• Actuation and monitoring of up to
127 extinguishing systems or 127
flooding zones
• Fully integrated into Fire Detection
Control Panel Series BC216
• Individual control panel or flexibly
expandable control panel network
• Suitable for all system sizes
• Optional hardware redundancy
• EN 54, EN 12094-1, VdS certified
Fire is a permanent threat to life and property. There- ted within LST premises, thus guaranteeing flexible and
fore, immediate response to a fire is imperative. The reliable individual solutions.
main objective of the Extinguishing Control Panels Se-
ries LC216 is to alarm and to react in time and, conse- Using a 32-bit multiprocessor system, the Extinguishing
quently, save lives and protect property. For decades Control Panels Series LC216 ensure topmost efficiency
LST have focused their aims to undertaking unrivaled and speed – prerequisites for saving lives and minimi-
efforts in order to realize new innovations in the security zing damage to property.
area. Research, development and production are loca-
Description
The Extinguishing Control Panel Series LC216 is an
extended Fire Detection Control Panel Series BC216
with additional functions for the control of extinguishing
systems. Nevertheless, all functions of the fire detec-
tion control panel remain intact. Therefore, a combined
use as fire detection and extinguishing control panel is
provided as standard.
are interconnected via the Global Security System
Network GSSnet and thereby form a decentralised
extinguishing control system. Each extinguishing sys-
tem can control up to 32 flooding zones, and each
LCnet sectional control panel can administrate up to
8 flooding zones. A maximum of 127 flooding zones
can be controlled by an Extinguishing Control Panel
LCnet216.
The Extinguishing Control Panels Series LC216 compri-
se the following types of control panels:
The Extinguishing Control Panel Series LC216 fulfils
• The Extinguishing Control Panel LC216-1 for an extin- all compulsory requirements as well as the options of
guishing system with one flooding zone according to EN 12094-1, EN 54-2 and EN 54-4 and is VdS certi-
EN 12094-1 or with up to 8 flooding zones without fied.
compliance to EN 12094-1.
• The networked Extinguishing Control Panel LCnet216 The networked Extinguishing Control Panel LCnet216
for up to 127 extinguishing systems. The LCnet216 can be easily implemented with a redundant design of
consists of several sectional control panels, which the extinguishing control.
0786–CPD–20267
Building Safety. Building Security.
A
© LABOR STRAUSS SICHERUNGSANLAGENBAU GMBH • A-1231 WIEN • WIEGELESTRASSE 36 • TEL +43 1 52114-0 • FAX +43 1 52114-27
LC216_DBL_LST_EN_0806.PDF • PAGE 1
[email protected] • WWW.LST.AT • ALL RIGHTS RESERVED
Download from Www.Somanuals.com. All Manuals Search And Download.
Features
The extinguishing control function is fully integrated into
the Fire Detection Control Panel Series BC216. The Ex-
cific functions for the actuation of the extinguishing
system.
tinguishing Control Panel Series LC216 comprises the • For the actuation of valves or signalling equipment,
following additional features:
various types of actuation are available, which can
be assigned to any outputs of the control panel or
to an ADM control module. The activation of these
actuations is timed according to EN 12094-1.
• The Extinguishing Control Panel LC216-1 serves for
the actuation of an extinguishing system with up to
8 flooding zones. By means of the networked Extin-
guishing Control Panel LCnet216, up to 127 extingu- • The condition of flooding zones or extinguishing sys-
ishing systems can be actuated. Each extinguishing
system can control up to 32 flooding zones, each
LCnet sectional control panel can administrate up to
8 flooding zones. A maximum of 127 flooding zones
tems can be output by the status outputs of the con-
trol panel or via ADM modules. Furthermore, status
LEDs can be freely parameterised as optical conditi-
on display.
can be controlled by an Extinguishing Control Panel • Depending on the size of the flooding zone and the
LCnet216.
capacity of the extinguishing agent cylinders, for
each flooding zone the actuation of further flooding
zones can be unblocked or blocked.
• All zones with automatic fire detectors or manual call
points can be used for the actuation of the extinguis-
hing system. The respective detectors and detector • In the appropriate authorisation level, a flooding zone
zones are assigned to the individual flooding zones
by defining combinations and dependencies.
• Input signals for the actuation of the extinguishing
system can be received through zone inputs in con-
ventional or ADM technology, as well as via fire briga-
de interface inputs.
can be operated at the display and operating unit of
the fire detection control panel. In addition to disab-
lements, enablements and toggling between manual
and automatic mode, it is also possible to test the
signalling equipment for pre-alarm and evacuation
alarm.
The ADM technology allows to connect detectors, • The Extinguishing Control Panel Series LC216 can
signalling devices as well as monitor and control mo-
dules in intelligent analogue ring bus technology. A
safe supply of the loop elements is achieved through
the redundant cable path. Therefore, standard fire
detection cable can be used for wiring.
• Various zone and input types, such as „Emergency
hold device“, „Manual mode“, „Extinguishing medium
active“ or „Reset extinguishing system“ provide spe-
be comfortably parameterised via PC by using the
Windows Parameter Setup Software PARSOFT. The
clear user interface allows an almost self-explanato-
ry definition of the system configuration and thereby
minimizes the requirement for training. The entered
parameters can be loaded into the control panel after
an automatic verification for technical correctness.
Advanced features
In addition to all compulsory functions of EN 12094-1, • Manual only mode
the extinguishing control panel fulfils the following opti- • Triggering signals to equipment within the system
ons of this standard:
• Extinguishing signals to spare cylinders
• Triggering of equipment outside the system
• Emergency abort device
• Control of extended discharge
• Release of the extinguishing media for selected floo-
ding zones
• Delay of extinguishing signal
• Signal representing the flow of extinguishing agent
• Monitoring of the status of components
• Emergency hold device
• Control of flooding time
• Initiation of secondary flooding
Redundant design
The Extinguishing Control Panel Series LC216 can be A redundant design of the extinguishing control panel
optionally implemented with a hardware-redundant de- can be implemented by means of the fire detection
sign. A redundant design is required according to the control panel modules in 19“ slide-in technology. The
standard EN 12094-1 for fixed gas extinguishing sys- parameterisation of the redundant extinguishing control
tems, if one sectional control panel actuates more than panel is fully supported by the Parameter Setup Softwa-
one extinguishing area.
re PARSOFT.
Building Safety. Building Security.
A
© LABOR STRAUSS SICHERUNGSANLAGENBAU GMBH • A-1231 WIEN • WIEGELESTRASSE 36 • TEL +43 1 52114-0 • FAX +43 1 52114-27
LC216_DBL_LST_EN_0806.PDF • PAGE 3
[email protected] • WWW.LST.AT • ALL RIGHTS RESERVED
Download from Www.Somanuals.com. All Manuals Search And Download.
Extinguishing control licence
The extinguishing control function is enabled in the or LCnet sectional control panel can be used for the
Extinguishing Control Panel LC216-1 and in any LCnet actuation of up to 8 flooding zones.
sectional control panel by installing an appropriately pa- The options circuit is part of the Extinguishing Cont-
rameterised options circuit. This control panel LC216-1 rol/8-Area Licence LC216-8LB.
Specifications
Extinguishing Control Panel LC216-1
Number of extinguishing systems
Number of flooding zones
1
max. 8
Extinguishing Control Panel LCnet216
Number of extinguishing systems per sectional control panel
Total number of extinguishing systems
1
max. 127
max. 8
max. 32
max. 127
Number of flooding zones per sectional control panel
Number of flooding zones per extinguishing system
Total number of flooding zones
Extinguishing control licence for 8 flooding zones
Approvals
CE marking
0786–CPD–20267
VdS G206046
VdS G206089
as pure extinguishing control panel
as combined fire detection and extinguishing control panel
FT 14/423/06 (Austria)
Order number
Order name
218024
Extinguishing Control/8-Area Licence LC216-8LB
Building Safety. Building Security.
A
© LABOR STRAUSS SICHERUNGSANLAGENBAU GMBH • A-1231 WIEN • WIEGELESTRASSE 36 • TEL +43 1 52114-0 • FAX +43 1 52114-27
LC216_DBL_LST_EN_0806.PDF • PAGE 4
[email protected] • WWW.LST.AT • ALL RIGHTS RESERVED