LSI Network Card 7102XP LC User Manual

USER’S  
GUIDE  
2 Gbit/s Fibre Channel  
Host Adapters  
LSI7102XP-LC, LSI7102LXP-LC  
LSI7202XP-LC, LSI7202LXP-LC  
LSI7402XP-LC  
LSI7202EP-LC, LSI7202EP  
LSI7402EP-LC, LSI7402EP  
Au g u s t 2 0 0 5  
Version 2.1  
®
DB15-000264-02  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Preface  
This book is the primary reference and user’s guide for the LSI Logic  
family of 2 Gbit/s Fibre Channel host adapter boards. It contains a  
complete functional description of these boards as well as complete  
physical and electrical specifications. LSI Logic uses Class 1 transceivers  
on the host adapter boards contained in this user’s guide.  
Audience  
This document assumes that you have some familiarity with  
Fibre Channel protocol and related support devices and will benefit  
persons installing and using these boards.  
Organization  
This document has the following chapters:  
Chapter 1, Installation Procedures, provides both quick and detailed  
installation instructions.  
Chapter 2, 2 Gbit/s FC Host Adapter Characteristics, describes the  
physical and operational environments of the host adapters.  
Chapter 3, Firmware Installation Procedure, describes the  
installation and configuration procedures for the Fusion-MPT™ and  
Fibre Channel drivers.  
Chapter 4, BIOS Features, describes the installation procedures for  
the Fibre Channel BIOS and Configuration Utility.  
2 Gbit/s Fibre Channel Host Adapters User’s Guide  
iii  
Copyright © 2002, 2005 by LSI Logic Corporation. All rights reserved.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Related Publications  
LSIFC929X Dual Channel Fibre Channel I/O Processor Technical  
Manual, Document No. DB14-000202-01  
LSIFC919X Single Channel Fibre Channel I/O Processor Technical  
Manual, Document No. DB15-000225-01  
Fusion-MPT™ Device Management User’s Guide, Volume 1.2,  
Document No. DB15-000186-01  
PCI Local Bus Specification, Rev. 2.2  
PCI-X/133 Local Bus Specification, Rev. 1.0a  
PCI Express Base Specification, Rev. 1.0a  
Revision Record  
Revision  
Date  
Remarks  
1.0  
2.0  
2.1  
10/02  
04/03  
08/05  
Preliminary release  
Final release  
Updated to add the LSI7102LXP-LC, LSI7202LXP-LC, LSI7202EP,  
LSI7202EP-LC, LSI7402EP, and LSI7402EP-LC.  
iv  
Preface  
Copyright © 2002, 2005 by LSI Logic Corporation. All rights reserved.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Contents  
Chapter 1  
Installation Procedures  
1.1  
1.2  
1.3  
General Description  
1-1  
1-2  
1-3  
Quick Installation Procedure  
1.3.1  
1.3.2  
Before You Start  
Installing the Host Adapter  
Chapter 2  
2 Gbit/s FC  
Host Adapter Characteristics  
2.1  
2.2  
General Description  
2-7  
2-7  
2-7  
2-8  
2-9  
Features  
2.2.1  
PCI-X Interface  
PCI Express Interface  
FC Interface  
2.2.2  
2.2.3  
2.3  
2.4  
Physical Environment  
2.3.1  
2.3.2  
2.3.3  
2.3.4  
Electrical Characteristics  
Electromagnetic Compliance  
Safety Characteristics  
Operational Environment  
2.4.1  
2.4.2  
2.4.3  
2.4.4  
PCI-X Interface  
PCI Express Interface  
FC Interface  
FC Link Activity/Link Fault LED  
2.5  
2.6  
2.7  
PCI System ID Values  
PCI Subsystem ID Values  
Unique World Wide Name  
2 Gbit/s Fibre Channel Host Adapters User’s Guide  
v
Copyright © 2002 - 2005 by LSI Logic Corporation. All rights reserved.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2.8  
Physical Characteristics  
2.8.1  
2.8.2  
2.8.3  
2.8.4  
2.8.5  
2.8.6  
2.8.7  
2.8.8  
2.8.9  
2-23  
2-24  
2.8.13 LSI7402XP-LC Host Adapter Configuration  
2.8.14 LSI7402XP-LC Connectors and Indicator LEDs  
2.8.15 LSI7402EP-LC Host Adapter Configuration  
Chapter 3  
Firmware Installation Procedure  
3.1  
FC Firmware  
3-2  
3.1.1  
3.1.2  
Features  
Description  
3.2  
3.3  
Download New FC Firmware  
Update the FC Firmware  
3.3.1  
3.3.2  
Windows  
3-7  
3.3.3  
Command Line Update Tool for DOS  
3.4  
3.5  
Advanced User: Adjusting Default Firmware Settings  
3-8  
3.4.1  
3.4.2  
Adjusting Link Speed  
3-9  
Adjusting Interrupt Coalescing  
3-10  
3-12  
Troubleshooting  
vi  
Contents  
Copyright © 2002 - 2005 by LSI Logic Corporation. All rights reserved.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 4  
BIOS Features  
4.1  
LSI Logic Boot BIOS  
4.1.1  
4.1.2  
4.1.3  
LSI Logic Boot BIOS Features  
BIOS Overview  
4.2  
4.3  
4.4  
Using the LSI Logic Boot BIOS CU  
Main Menu  
4.4.1  
4.4.2  
4.4.3  
4.4.4  
4.4.5  
Adapter Properties Menu  
Persistent ID Menu  
Device Properties Menu  
Boot Adapter List Menu  
Global Properties Menu  
4.5  
4.6  
4.7  
Troubleshooting  
OpenBoot BIOS  
4.7.1  
4.7.2  
4.7.3  
4.7.4  
4.7.5  
4.7.6  
4.7.7  
4.7.8  
OpenBoot BIOS Features  
Identifying the FC Devices  
Verifying Installation  
Adapter-Specific Settings  
4-10  
4-14  
4-15  
4-17  
Set FC Link Speed  
Persistent Device Naming  
Manual Selection of FC Topology  
Customer Feedback  
Contents  
vii  
Copyright © 2002 - 2005 by LSI Logic Corporation. All rights reserved.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
viii  
Contents  
Copyright © 2002 - 2005 by LSI Logic Corporation. All rights reserved.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Figures  
1.1  
1.2  
2.1  
2.2  
2.3  
2.4  
2.5  
2.6  
2.7  
2.8  
2.9  
Hardware Connections for the LSI Logic Host Adapter  
Inserting the LSI Logic Host Adapter  
LSI7102XP-LC Host Adapter Configuration  
LSI7102LXP-LC Host Adapter Configuration  
LSI7202XP-LC Host Adapter Configuration  
LSI7202LXP-LC Host Adapter Configuration  
LSI7202EP-LC Host Adapter Configuration  
2.11 LSI7202EP Host Adapter Configuration  
2.12 LSI7202EP Connectors and Indicator LEDs  
2.13 LSI7402XP-LC Host Adapter Configuration  
2.15 LSI7402EP-LC Host Adapter Configuration  
2.17 LSI7402EP Host Adapter Configuration  
2.18 LSI7402EP Connectors and Indicator LEDs  
3.1  
3.2  
3.3  
3.4  
3.5  
3.6  
4.1  
4.2  
4.3  
4.4  
4.5  
LSIUtil Device Selection  
LSIUtil Download Options  
LSIUtil File Download  
MPTUtil Device Selection  
MPTUtil Options  
Interrupt Coalescing Values  
Select Controller  
4-15  
4-16  
4-16  
4-16  
4-16  
Select Device  
Inserting Disk Name in Command Line  
Setting Device 0 as Persistent  
Clearing Persistent Device Map  
ix  
Copyright © 2002 - 2005 by LSI Logic Corporation. All rights reserved.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
x
Copyright © 2002 - 2005 by LSI Logic Corporation. All rights reserved.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Tables  
2.1  
2.2  
2.3  
2.4  
2.5  
2.6  
2.7  
2.8  
2.9  
LSI Logic 2 Gbit/s FC Host Adapter Descriptions  
Hardware and Software Requirements  
Maximum Power Requirements  
LED Appearance to Represent Link Status  
PCI System ID Values  
PCI Subsystem ID Values  
LSI7102XP-LC Link Activity/Link Fault LEDs  
LSI7102LXP-LC Link Activity/Link Fault LEDs  
LSI7202XP-LC Link Activity/Link Fault LEDs  
2-19  
2-21  
2-23  
2-25  
2-27  
2.10 LSI7202LXP-LC Link Activity/Link Fault LEDs  
2.11 LSI7202EP-LC Link Activity/Link Fault LEDs  
2.12 LSI7202EP Link Activity/Link Fault LEDs  
2.13 LSI7402XP-LC Link Activity/Link Fault LEDs  
2.14 LSI7402EP-LC Link Activity/Link Fault LEDs  
2.15 LSI7402EP Link Activity/Link Fault LEDs  
xi  
Copyright © 2002 - 2005 by LSI Logic Corporation. All rights reserved.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
xii  
Copyright © 2002 - 2005 by LSI Logic Corporation. All rights reserved.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 1  
Installation Procedures  
This chapter contains general information about the LSI Logic 2 Gbit/s  
family of Fibre Channel (FC) host adapters. It also provides host adapter  
installation instructions. This chapter describes these topics in the  
following sections:  
Section 1.1, “General Description”  
Section 1.2, “Quick Installation Procedure”  
Section 1.3, “Detailed Installation Procedure”  
1.1 General Description  
LSI Logic provides high-performance, cost-effective 2 Gbit/s FC  
controllers and host adapters. The LSI Logic controllers and their  
associated host adapters that support 2 Gbit/s FC contained in this  
User’s Guide are as follows:  
Controller  
Host Adapter  
LSIFC919X LSI7102XP-LC, LSI7102LXP-LC  
LSIFC929X LSI7202XP-LC, LSI7202LXP-LC, LSI7202EP-LC, LSI7202EP,  
LSI7402XP-LC, LSI7402EP-LC, LSI7402EP  
Installing these host adapters into your PCI-X system allows you to  
connect FC devices. You can use these FC boards in computer systems  
with a standard bracket type or with a low profile bracket  
(LSI7102LXP-LC or LSI7202LXP-LC).  
For specific information about the FC controllers, refer to LSIFC929X Dual  
Channel Fibre Channel I/O Processor Technical Manual and LSIFC919X  
Single Channel Fibre Channel I/O Processor Technical Manual.  
2 Gbit/s Fibre Channel Host Adapters User’s Guide  
Copyright © 2002 - 2005 by LSI Logic Corporation. All rights reserved.  
1-1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
1.2 Quick Installation Procedure  
This section provides an overview of the installation procedure. If you are  
an experienced computer user with prior host adapter installation and FC  
setup experience, this section may describe the procedure sufficiently. If  
you prefer more detailed guidance for installing the host adapter, proceed  
to Section 1.3, “Detailed Installation Procedure.”  
For safe and proper installation, refer to the user’s manual supplied with  
your computer and perform the following steps:  
Step 1. Ground yourself before removing this host adapter board.  
Step 2. Remove the host adapter from the packaging and check that it  
is not damaged.  
Figure 1.1 on page 1-4 illustrates an example of this host  
adapter board. Also refer to Chapter 2, “2 Gbit/s FC Host  
Adapter Characteristics,to see more detailed drawings of the  
2 Gbit/s host adapter boards.  
Step 3. Open your PC cabinet and select an appropriate open PCI slot.  
Step 4. Insert the host adapter board.  
Step 5. Make any configuration changes.  
Step 6. Close your PC cabinet cover.  
Step 7. Connect the FC cable to the host adapter.  
1-2  
Installation Procedures  
Copyright © 2002 - 2005 by LSI Logic Corporation. All rights reserved.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
1.3 Detailed Installation Procedure  
This section provides step-by-step instructions for installing the host  
adapter. If you are experienced in these tasks, you may prefer to use  
Section 1.2, “Quick Installation Procedure.”  
1.3.1 Before You Start  
Before starting, look through the following task list to get an overall idea of  
the steps you will perform. If you are not confident you can perform the  
tasks as described here, LSI Logic recommends getting assistance.  
Each FC host adapter channel that you install can act as a host for up  
to 126 Arbitrated Loop FC devices, not including the adapter itself. Follow  
the detailed instructions in Section 1.3.2, “Installing the Host Adapter,”  
to install your host adapter board successfully.  
1.3.2 Installing the Host Adapter  
For safe and proper installation, refer to the user’s manual supplied with  
your computer and perform the following steps to install the host adapter.  
Step 1. Ground yourself before removing this host adapter board.  
Step 2. Remove the host adapter from the packaging and check that it  
is not damaged.  
Figure 1.1 illustrates an example of this host adapter board.  
Also refer to Chapter 2, “2 Gbit/s FC Host Adapter  
Characteristics,to see more detailed drawings of the 2 Gbit/s  
host adapter boards.  
Step 3. Switch off the computer and unplug the power cords for all  
components in your system.  
Step 4. Remove the cover from your computer according to the  
instructions in the user’s manual for your system, to access the  
PCI slots.  
Caution:  
Ground yourself by touching a metal surface before  
removing the cabinet top. Static charges on your body can  
damage electronic components. Handle plug-in boards by  
the edge; do not touch board components or gold  
Detailed Installation Procedure  
Copyright © 2002 - 2005 by LSI Logic Corporation. All rights reserved.  
1-3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
connector contacts. LSI Logic recommends using a static  
ground strap.  
Step 5. Locate the slots for PCI plug-in board installation.  
Refer to the user’s manual supplied with your computer to  
confirm the location of the PCI slots.  
This host adapter requires a 32-bit or 64-bit PCI slot that allows  
bus master operation. If a 32-bit PCI slot is used, the portion of  
the J1 connector opposite the bracket remains uninserted.  
Refer to Table 1.2 for details.  
Note:  
For this host adapter to function as a 64-bit device, it must  
be inserted into a 64-bit PCI slot. If the host adapter is  
inserted into a 32-bit PCI slot, it functions as a 32-bit  
device.  
Step 6. On the back of the computer, remove the blank bracket panel  
that is aligned with the PCI slot you intend to use. Save the  
bracket screw.  
Figure 1.1 Hardware Connections for the LSI Logic Host Adapter  
Fibre Channel  
Link Activity/  
Link Fault LED  
SFP  
Transceiver  
LSI Logic Host Adapter  
PCI Bus Edge Connector J1  
1-4  
Installation Procedures  
Copyright © 2002 - 2005 by LSI Logic Corporation. All rights reserved.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Step 7. Carefully insert PCI Bus edge connector J1 (see Figure 1.1) of  
the host adapter into the PCI slot.  
Make sure the edge connector is properly aligned before  
pressing the board into place, as shown in Figure 1.2. The  
bracket around the Small Form-Factor Pluggable (SFP)  
transceiver cages should fit where you removed the blank panel.  
Figure 1.2 Inserting the LSI Logic Host Adapter  
Bracket Screw  
32-Bit PCI Slots  
64-Bit PCI Slots  
Step 8. Secure the board with the bracket screw (see Figure 1.2), then  
make the external FC link connection.  
Detailed Installation Procedure  
Copyright © 2002 - 2005 by LSI Logic Corporation. All rights reserved.  
1-5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
1-6  
Installation Procedures  
Copyright © 2002 - 2005 by LSI Logic Corporation. All rights reserved.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 2  
2 Gbit/s FC  
Host Adapter  
Characteristics  
This chapter provides specific details about the physical environment  
associated with the 2 Gbit/s family of FC host adapters. This chapter  
includes the following sections:  
Section 2.1, “General Description”  
Section 2.2, “Features”  
Section 2.3, “Physical Environment”  
Section 2.4, “Operational Environment”  
Section 2.5, “PCI System ID Values”  
Section 2.6, “PCI Subsystem ID Values”  
Section 2.7, “Unique World Wide Name”  
Section 2.8, “Physical Characteristics”  
2.1 General Description  
The LSI Logic 2 Gbit/s family of FC host adapters makes use of state-of-  
the-art, 2 Gbit/s FC technology to provide the highest possible  
performance and most flexible storage configuration available. These  
LSI Logic host adapters support 1 Gbit/s or 2 Gbit/s FC speeds, and  
detect and correctly set the speed of operation automatically. LSI Logic  
host adapters are available with LC optical interfaces using optical  
SFP transceivers.  
These LSI Logic FC host adapters offer the highest degree of integration  
available for your PCI-X or PCI Express based computer system,  
allowing for maximum performance, optimized use of system resources,  
and true Plug and Play installation.  
2 Gbit/s Fibre Channel Host Adapters User’s Guide  
Copyright © 2002 - 2005 by LSI Logic Corporation. All rights reserved.  
2-1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
This manual serves as a step-by-step guide during the installation of your  
LSI Logic host adapter.  
Table 2.1 lists the 2 Gbit/s FC host adapters discussed in this User’s  
Guide.  
Table 2.1  
Adapter  
LSI Logic 2 Gbit/s FC Host Adapter Descriptions  
Description  
LSI7102XP-LC 2 Gbit/s, PCI-X, single-port, standard height bracket, optical  
LSI7102LXP-LC 2 Gbit/s, PCI-X, single-port, low-profile bracket, optical  
LSI7202XP-LC 2 Gbit/s, PCI-X, dual-port, standard height bracket, optical  
LSI7202LXP-LC 2 Gbit/s, PCI-X, dual-port, low-profile bracket, optical  
2 Gbit/s, PCI Express, dual-port, standard height bracket,  
LSI7202EP-LC  
optical  
2 Gbit/s, PCI Express, dual-port, standard height bracket, no  
LSI7202EP  
optics  
LSI7402XP-LC 2 Gbit/s, PCI-X, quad-port, standard height bracket, optical  
2 Gbit/s, PCI Express, quad-port, standard height bracket,  
LSI7402EP-LC  
optical  
2 Gbit/s, PCI Express, quad-port, standard height bracket, no  
LSI7402EP  
optics  
Hardware and Software Support – The LSI Logic 2 Gbit/s family of FC  
host adapter supports most major software operating systems, such as  
Sun Solaris (2.6 and greater), Windows Server (NT 4.0, 2000, XP, 2003),  
Linux (RedHat, Suse, Caldera, Turbo), NetWare, and UnixWare. These  
host adapters use the Fusion-MPT architecture for all major operating  
systems. Fusion-MPT architecture offers the unique feature of having a  
single binary operating system driver that supports FC devices and other  
bus architectures. Refer to the Fusion-MPT Device Management User’s  
Guide for details regarding software support for this family of host  
adapters.  
Before you use any of this family of host adapters, make sure your system  
meets the specific hardware and software requirements shown in Table 2.2.  
2-2  
2 Gbit/s FC Host Adapter Characteristics  
Copyright © 2002 - 2005 by LSI Logic Corporation. All rights reserved.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Table 2.2  
Hardware and Software Requirements  
Component Requirements  
For Solaris SPARC hardware environments  
Hardware  
Software  
Firmware  
Any Sun Microsystems computer with a 3.3 V PCI slot  
Solaris 8 operating environment  
OpenBoot PROM, version 2.1 or greater  
For Intel IA-32 or IA-64 hardware environments  
Hardware  
Software  
Firmware  
Any Intel-compatible system with 3.3 V PCI slots  
Windows Server (NT 4.0, 2000, XP, 2003)  
Linux (Red Hat, Suse, Caldera, Turbo),  
NetWare, and UnixWare.  
Any Intel-compatible BIOS system  
2.2 Features  
This section provides an overview of the PCI-X Interface, the PCI  
Express Interface, and the FC Interface for the 2 Gbit/s family of host  
adapters.  
2.2.1 PCI-X Interface  
PCI-X interfaces I/O components to the processor and memory  
subsystems in equipment ranging from PCs to servers. The PCI-X interface  
operates as a 64-bit DMA bus master capable of 64-bit addressing.  
The PCI-X interface includes the following features:  
Full 64-bit DMA bus master  
LSIFC929X/LSIFC919X functionality:  
Zero wait-state bus master data bursts up to 1 Kbyte  
Host adapters comply with PCI Local Bus Specification, Rev. 2.2  
3.3 V interface  
Serial EEPROM configuration storage  
Host adapters comply with PCI-X/133 Local Bus Specification,  
Rev. 1.0a  
Features  
2-3  
Copyright © 2002 - 2005 by LSI Logic Corporation. All rights reserved.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
2.2.2 PCI Express Interface  
The PCI Express (launched in 2002) interface is a new serial I/O  
interface standard being used in next generation computer, storage and  
communications platforms. This scalable interface allows vendors to  
choose the number of 2.5 Gbit serial lanes (two to 16) most suitable to  
their product design and application need.  
The PCI Express interface featured on the LSI Logic Fibre to PCI  
Express boards includes:  
8 serial I/O lanes, 2.5 GHz, full duplex  
Fully PCI-compatible software model  
Serial EEPROM configuration storage  
2.2.3 FC Interface  
The LSIFC929X and LSIFC919X processors contain the FC functionality  
for all the LSI Logic 2 Gbit/s FC host adapters. The LSIFC929X and  
LSIFC919X processors generate signal timing and link protocol in  
compliance with FC standards.  
The FC interface includes these features:  
2 Gbit/s serial link  
LSIFC929X and LSIFC919X processor functionality:  
Class 3, Arbitrated Loop (AL), Fabric, Point-to-Point  
2 Kbyte frame payloads  
Multiframe buffering  
Link activity/link fault LED  
2.3 Physical Environment  
This section provides information about the physical, electrical, thermal,  
and safety characteristics of the LSI Logic 2 Gbit/s family of FC host  
adapters. Additionally, these boards are compliant with FCC  
electromagnetic standards.  
2-4  
2 Gbit/s FC Host Adapter Characteristics  
Copyright © 2002 - 2005 by LSI Logic Corporation. All rights reserved.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
2.3.1 Electrical Characteristics  
Table 2.3 lists the maximum power requirements and includes all of the  
LSI Logic 2 Gbit/s FC host adapter boards under normal operation.  
Table 2.3  
Maximum Power Requirements  
Host Adapter  
PCI +3.3 V  
Over the Operating Range  
LSI7102XP-LC  
4.7 W @ 3.6 V  
0 ˚C to 55 ˚C  
0 ˚C to 55 ˚C  
0 ˚C to 55 ˚C  
0 ˚C to 55 ˚C  
0 ˚C to 55 ˚C  
LSI7102LXP-LC 4.7 W @ 3.6 V  
LSI7202XP-LC 6.5 W @ 3.6 V  
LSI7202LXP-LC 6.5 W @ 3.6 V  
LSI7202EP-LC  
11.5 W @ 12.6 V  
10.7 W @ 12.6 V  
plus SFP power, if any  
LSI7202EP  
0 ˚C to 55 ˚C  
14.7 W @ 3.6 V  
plus 4.2 W @ 5.25 V  
LSI7402XP-LC  
LSI7402EP-LC  
LSI7402EP  
0 ˚C to 55 ˚C  
0 ˚C to 55 ˚C  
0 ˚C to 55 ˚C  
16.0 W @ 12.6 V  
14.4 W @ 12.6 V  
plus SFP power, if any  
2.3.2 Thermal, Atmospheric Characteristics  
The thermal, atmospheric characteristics of the LSI Logic 2 Gbit/s family  
of FC host adapters are:  
Temperature range: 0 °C to 55 °C (dry bulb), 100 linear feet per  
minute (LFPM) airflow minimum  
Relative humidity range: 5% to 90% noncondensing  
Maximum dew point temperature: 32 °C  
The following parameters define the storage and transit environment for  
the LSI Logic 2 Gbit/s family of FC host adapters:  
Storage Temperature: 45 °C to +85 °C (dry bulb)  
Relative Humidity Range: 0% to 95%, noncondensing  
Physical Environment  
Copyright © 2002 - 2005 by LSI Logic Corporation. All rights reserved.  
2-5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
2.3.3 Electromagnetic Compliance  
These boards are designed and implemented to minimize susceptibility  
to electromagnetic emissions, and the effects of electromagnetic  
discharge. The boards are tested to comply with Class B and carry  
markings for CE, VCCI, Canada, C-Tick, and the FCC.  
2.3.4 Safety Characteristics  
The bare boards meet the requirements of flammability rating UL 94 V-0.  
The bare boards are also marked with the supplier name or trademark,  
type, and UL flammability rating. Because these boards are installed in  
a PCI bus slot, all voltages are below the SELV 42.4 V limit.  
2.4 Operational Environment  
Use the LSI Logic 2 Gbit/s family of FC host adapters in PCI-X or PCI  
Express computer systems with an Industry Standard  
Architecture/Extended Industry Standard Architecture (ISA/EISA) bracket  
type. The LSI Logic-supplied FC BIOS and firmware operate the host  
adapters. An on-board flash memory device and a serial EEPROM are  
provided to allow BIOS code and OpenBoot code support over the PCI  
bus.  
2.4.1 PCI-X Interface  
The PCI-X interface operates as a 64-bit DMA bus master. The edge  
connector makes the PCI-X connection, which provides connections on  
both the front and back of the board. The signal definitions and pin  
numbers conform to the PCI-X/133 Specification, Revision 1.0a. Refer to  
that specification for details regarding the signal assignments.  
2.4.2 PCI Express Interface  
The LSI Logic PCI Express interface operates as a x8 lane DMA bus  
master. The narrow edge connector makes the PCI Express connection,  
which provides connections on both the front and back of the board. The  
signal definitions and pin numbers conform to the PCI Express base  
Specification, Revision 1.0a. Refer to that specification for details  
regarding the signal assignments.  
2-6  
2 Gbit/s FC Host Adapter Characteristics  
Copyright © 2002 - 2005 by LSI Logic Corporation. All rights reserved.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
         
2.4.3 FC Interface  
The FC interface varies, depending on which LSI Logic 2 Gbit/s host  
adapter you have selected. Refer to Section 2.8, “Physical  
Characteristics,page 2-9 for details.  
2.4.4 FC Link Activity/Link Fault LED  
The LSI Logic 2 Gbit/s host adapters provide dual-purpose LEDs that  
indicate activity on the FC link. These LEDs (one per port) are visible  
near the ports on the bracket. Figure 2.4 shows the appearance of the  
Link Activity/Link Fault LED that represents the given link status for each  
of the LSI Logic host adapters.  
Table 2.4  
LED Appearance to Represent Link Status  
Adapter  
Link  
Off  
Off  
Off  
Off  
Off  
Off  
Off  
Off  
Off  
Activity  
Fault  
LSI7102XP-LC  
LSI7102LXP-LC  
LSI7202XP-LC  
LSI7202LXP-LC  
LSI7202EP-LC  
LSI7202EP  
Green Blinking  
Green Blinking  
Green Blinking  
Green Blinking  
Green Blinking  
Green Blinking  
Green Blinking  
Green Blinking  
Green Blinking  
Yellow  
Yellow  
Yellow  
Yellow  
Yellow  
Yellow  
Yellow  
Yellow  
Yellow  
LSI7402XP-LC  
LSI7402EP-LC  
LSI7402EP  
2.5 PCI System ID Values  
All LSI Logic 2 Gbit/s host adapters share common PCI Vendor ID (VID)  
values and are assigned device ID (DID) values to allow drivers and  
BIOS to recognize them as 2 Gbit/s capable FC products. Table 2.1  
provides the VID and DID for all LSI Logic 2 Gbit/s FC host adapters.  
PCI System ID Values  
Copyright © 2002 - 2005 by LSI Logic Corporation. All rights reserved.  
2-7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
Table 2.5  
PCI System ID Values  
Host Adapter  
VID Number  
DID Number  
0x0628  
0x0628  
0x0626  
0x0626  
0x0626  
0x0626  
0x0626  
0x0626  
0x0626  
LSI7102XP-LC  
0x1000  
LSI7102LXP-LC  
LSI7202XP-LC  
LSI7202LXP-LC  
LSI7402XP-LC  
LSI7202EP-LC  
LSI7202EP  
0x1000  
0x1000  
0x1000  
0x1000  
0x1000  
0x1000  
0x1000  
0x1000  
LSI7402EP-LC  
LSI7402EP  
2.6 PCI Subsystem ID Values  
All LSI Logic 2 Gbit/s host adapters are assigned PCI Subsystem Vendor  
IDs (SVIDs) and Subsystem IDs (SSIDs) to allow drivers and BIOS to  
differentiate the individual host adapter variants. The SVID and SSID are  
listed below. Table 2.6 provides the SVID and SSID for all the LSI Logic  
2 Gbit/s FC host adapters discussed in this user’s guide.  
Table 2.6  
PCI Subsystem ID Values  
Host Adapter  
SVID Number  
SSID Number  
0x0530  
0x0530  
0x1010  
0x1010  
0x1020  
0x1180  
0x1170  
0x1090  
0x1190  
LSI7102XP-LC  
0x1000  
LSI7102LXP-LC  
LSI7202XP-LC  
LSI7202LXP-LC  
LSI7402XP-LC  
LSI7202EP-LC  
LSI7202EP  
0x1000  
0x1000  
0x1000  
0x1000  
0x1000  
0x1000  
0x1000  
0x1000  
LSI7402EP-LC  
LSI7402EP  
2-8  
2 Gbit/s FC Host Adapter Characteristics  
Copyright © 2002 - 2005 by LSI Logic Corporation. All rights reserved.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
2.7 Unique World Wide Name  
Each LSI Logic FC host adapter is provided with a unique World Wide  
Name, specified by IEEE. The last 12 hexadecimal characters of this  
address appear on a host adapter label. This address is stored in the  
host adapter serial EEPROM.  
2.8 Physical Characteristics  
The LSI Logic 2 Gbit/s family of FC host adapters includes one to four  
external FC connectors, depending on the host adapter you have  
chosen. The host adapters are all available with optical or copper  
interconnects. No host adapter configuration is necessary.  
2.8.1 LSI7102XP-LC Host Adapter Configuration  
The LSI Logic LSI7102XP-LC is a single channel 2 Gbit/s FC adapter.  
One LC optical connector is used for I/O, which is accessible through the  
module bracket. The LSI7102XP-LC host adapter uses the LSIFC919X  
processor, providing one Fusion-MPT channel.  
The LSI7102XP-LC is a PCI short card; the dimensions are  
6.625 inches x 2.53 inches. The external FC connections are made  
through a 2 Gbit/s SFP optical module.  
The component height on the top and bottom of the board conforms to  
the PCI-X/133 Specification, Revision 1.0a. Figure 2.1 illustrates the  
major components on the LSI7102XP-LC.  
Unique World Wide Name  
Copyright © 2002 - 2005 by LSI Logic Corporation. All rights reserved.  
2-9  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Figure 2.1 LSI7102XP-LC Host Adapter Configuration  
LSI7102XP-LC  
Flash  
(Back)  
LSIFC919X  
Osc.  
Voltage  
Regulator  
SRAM (X2)  
Port 0, SFP  
J1_T  
2.8.2 LSI7102XP-LC Connector and Indicator LED  
The LSI7102XP-LC I/O bracket is configured as shown in Figure 2.2. The  
LC connector provides the connection from the adapter channel to the  
FC subsystem. The indicator LED indicates link status, activity, and link  
fault.  
2-10  
2 Gbit/s FC Host Adapter Characteristics  
Copyright © 2002 - 2005 by LSI Logic Corporation. All rights reserved.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Figure 2.2 LSI7102XP-LC Connector and Indicator LED  
Port 0  
Port 0 LED  
Table 2.7 describes the LSI7102XP-LC Link Activity/Link Fault LED  
appearance that indicates a valid link, presence of link activity, or a fault  
on the link.  
Table 2.7  
LSI7102XP-LC Link Activity/Link Fault LEDs  
Link  
Activity  
Fault  
LED Appearance  
Off  
Green Blinking  
Yellow  
Physical Characteristics  
Copyright © 2002 - 2005 by LSI Logic Corporation. All rights reserved.  
2-11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
2.8.3 LSI7102LXP-LC Host Adapter Configuration  
The LSI Logic LSI7102LXP-LC is a single channel 2 Gbit/s FC adapter.  
One LC optical connector is used for I/O, which is accessible through the  
module bracket. The LSI7102LXP-LC host adapter uses the LSIFC919X  
processor, providing one Fusion-MPT channel.  
The LSI7102LXP-LC is a PCI short card; the dimensions are  
6.625 inches x 2.53 inches. The external FC connections are made  
through a 2 Gbit/s SFP optical module.  
The component height on the top and bottom of the board conforms to  
the PCI-X/133 Specification, Revision 1.0a. Figure 2.3 illustrates the  
major components on the LSI7102LXP-LC.  
Figure 2.3 LSI7102LXP-LC Host Adapter Configuration  
LSI7102XP-LC  
Flash  
(Back)  
LSIFC919X  
Osc.  
Voltage  
Regulator  
SRAM (X2)  
Port 0, SFP  
J1_T  
2-12  
2 Gbit/s FC Host Adapter Characteristics  
Copyright © 2002 - 2005 by LSI Logic Corporation. All rights reserved.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
2.8.4 LSI7102LXP-LC Connector and Indicator LED  
The LSI7102LXP-LC I/O bracket is configured as shown in Figure 2.4.  
The LC connector provides the connection from the adapter channel to  
the FC subsystem. The indicator LED indicates link status, activity, and  
link fault.  
Figure 2.4 LSI7102LXP-LC Connector and Indicator LED  
Port 0  
Port 0 LED  
Table 2.8 describes the LSI7102LXP-LC Link Activity/Link Fault LED  
appearance that indicates a valid link, presence of link activity, or a fault  
on the link.  
Table 2.8  
LSI7102LXP-LC Link Activity/Link Fault LEDs  
Link  
Activity  
Fault  
LED Appearance  
Off  
Green Blinking  
Yellow  
Physical Characteristics  
Copyright © 2002 - 2005 by LSI Logic Corporation. All rights reserved.  
2-13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
2.8.5 LSI7202XP-LC Host Adapter Configuration  
The LSI Logic LSI7202XP-LC is a dual-channel, 2 Gbit/s FC adapter.  
Two LC optical connectors, used for I/O, are accessible through the  
module bracket. The LSI7202XP-LC uses the LSIFC929X, providing two  
Fusion-MPT channels.  
The LSI7202XP-LC is a PCI short card; the dimensions are 6.625 inches  
x 2.53 inches. The external FC connections are made through the  
2 Gbit/s SFP optical modules.  
The component height on the top and bottom of the board conforms to  
the PCI-X/133 Specification, Revision 1.0a. Figure 2.5 illustrates the  
major components on the LSI7202XP-LC.  
Figure 2.5 LSI7202XP-LC Host Adapter Configuration  
LSI7202XP-LC  
Flash  
(Back)  
Port 1, SFP  
LSIFC929X  
Osc.  
Voltage  
SRAM (X2)  
Regulator  
Port 0, SFP  
J1_T  
2-14  
2 Gbit/s FC Host Adapter Characteristics  
Copyright © 2002 - 2005 by LSI Logic Corporation. All rights reserved.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
2.8.6 LSI7202XP-LC Connectors and Indicator LEDs  
The LSI7202XP-LC I/O bracket is configured as shown in Figure 2.6. The  
LC connectors provide the connections from the adapter channels to the  
FC subsystem. The indicator LEDs indicate link status, activity, and link  
fault.  
Figure 2.6 LSI7202XP-LC Connectors and Indicator LEDs  
Port 1 LED  
Port 1  
Port 0  
Port 0 LED  
Table 2.9 describes the LSI7202XP-LC Link Activity/Link Fault LED  
appearance that indicates a valid link, presence of link activity, or a fault  
on the link.  
Table 2.9  
LSI7202XP-LC Link Activity/Link Fault LEDs  
Link  
Activity  
Fault  
LED Appearance  
Off  
Green Blinking  
Yellow  
Physical Characteristics  
Copyright © 2002 - 2005 by LSI Logic Corporation. All rights reserved.  
2-15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
2.8.7 LSI7202LXP-LC Host Adapter Configuration  
The LSI Logic LSI7202LXP-LC is a dual-channel, 2 Gbit/s FC adapter.  
Two LC optical connectors, used for I/O, are accessible through the  
module bracket. The LSI7202LXP-LC uses the LSIFC929X, providing  
two Fusion-MPT channels.  
The LSI7202LXP-LC is a PCI short card; the dimensions are  
6.625 inches x 2.53 inches. The external FC connections are made  
through the 2 Gbit/s SFP optical modules.  
The component height on the top and bottom of the board conforms to  
the PCI-X/133 Specification, Revision 1.0a. Figure 2.7 illustrates the  
major components on the LSI7202LXP-LC.  
Figure 2.7 LSI7202LXP-LC Host Adapter Configuration  
LSI7202XP-LC  
Flash  
(Back)  
Port 1, SFP  
LSIFC929X  
Osc.  
Voltage  
SRAM (X2)  
Regulator  
Port 0, SFP  
J1_T  
2-16  
2 Gbit/s FC Host Adapter Characteristics  
Copyright © 2002 - 2005 by LSI Logic Corporation. All rights reserved.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
2.8.8 LSI7202LXP-LC Connectors and Indicator LEDs  
The LSI7202LXP-LC I/O bracket is configured as shown in Figure 2.8.  
The LC connectors provide the connections from the adapter channels to  
the FC subsystem. The indicator LEDs indicate link status, activity, and  
link fault.  
Figure 2.8 LSI7202LXP-LC Connectors and Indicator LEDs  
Port 1 LED  
Port 1  
Port 0  
Port 0 LED  
Table 2.10 describes the LSI7202LXP-LC Link Activity/Link Fault LED  
appearance that indicates a valid link, presence of link activity, or a fault  
on the link.  
Table 2.10 LSI7202LXP-LC Link Activity/Link Fault LEDs  
Link  
Activity  
Fault  
LED Appearance  
Off  
Green Blinking  
Yellow  
Physical Characteristics  
Copyright © 2002 - 2005 by LSI Logic Corporation. All rights reserved.  
2-17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
2.8.9 LSI7202EP-LC Host Adapter Configuration  
The LSI Logic LSI7202EP-LC is a dual-channel, 2 Gbit/s FC adapter.  
Two LC optical connectors, used for I/O, are accessible through the  
module bracket. The LSI7202EP-LC uses the LSIFC929X, providing two  
Fusion-MPT channels.  
The LSI7202EP-LC is a PCI short card; the dimensions are 6.875 inches  
x 4.2 inches. The external FC connections are made through the 2 Gbit/s  
SFP optical modules.  
The component height on the top and bottom of the board conforms to  
the PCI Express Specification, Revision 1.0a. Figure 2.9 illustrates the  
major components on the LSI7202EP-LC.  
Figure 2.9 LSI7202EP-LC Host Adapter Configuration  
LSI7202EP-LC  
Flash  
(Back)  
SRAM  
(X2)  
LSIFC929X  
Flash  
(Back)  
Port 1, SFP  
Port 0, SFP  
PCI Express  
Bridge  
Osc.  
Voltage  
Regulator  
SRAM (X2)  
2-18  
2 Gbit/s FC Host Adapter Characteristics  
Copyright © 2002 - 2005 by LSI Logic Corporation. All rights reserved.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
2.8.10 LSI7202EP-LC Connectors and Indicator LEDs  
The LSI7202EP-LC I/O bracket is configured as shown in Figure 2.10.  
The Port 0 and Port 1 connectors provide the connections from the  
adapter channels to the FC subsystem. The indicator LEDs indicate link  
status, activity, and link fault.  
Figure 2.10 LSI7202EP-LC Connectors and Indicator LEDs  
Port 1 LED  
Port 1  
Port 0  
Port 0 LED  
Table 2.11 describes the LSI7202EP-LC Link Activity/Link Fault LED  
appearance that indicates a valid link, presence of link activity, or a fault  
on the link.  
Table 2.11 LSI7202EP-LC Link Activity/Link Fault LEDs  
Link  
Activity  
Fault  
LED Appearance  
Off  
Green Blinking  
Yellow  
Physical Characteristics  
Copyright © 2002 - 2005 by LSI Logic Corporation. All rights reserved.  
2-19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
2.8.11 LSI7202EP Host Adapter Configuration  
The LSI Logic LSI7202EP is a dual-channel, 2 Gbit/s FC adapter. Two  
connectors, used for I/O, are accessible through the module bracket. The  
LSI7202EP uses the LSIFC929X, providing two Fusion-MPT channels.  
The LSI7202EP is a PCI short card; the dimensions are 6.875 inches  
x 4.2 inches. The external FC connections are made through the 2 Gbit/s  
SFP optical modules.  
The component height on the top and bottom of the board conforms to  
the PCI Express Specification, Revision 1.0a. Figure 2.11 illustrates the  
major components on the LSI7202EP.  
Figure 2.11 LSI7202EP Host Adapter Configuration  
LSI7202EP  
Flash  
(Back)  
SRAM  
(X2)  
LSIFC929X  
Flash  
(Back)  
Port 1, SFP  
Port 0, SFP  
PCI Express  
Bridge  
Osc.  
Voltage  
Regulator  
SRAM (X2)  
2-20  
2 Gbit/s FC Host Adapter Characteristics  
Copyright © 2002 - 2005 by LSI Logic Corporation. All rights reserved.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
2.8.12 LSI7202EP Connectors and Indicator LEDs  
The LSI7202EP I/O bracket is configured as shown in Figure 2.12. The  
Port 0 and Port 1 connectors provide the connections from the adapter  
channels to the FC subsystem. The indicator LEDs indicate link status,  
activity, and link fault.  
Figure 2.12 LSI7202EP Connectors and Indicator LEDs  
Port 1 LED  
Port 1  
Port 0  
Port 0 LED  
Table 2.12 describes the LSI7202EP Link Activity/Link Fault LED  
appearance that indicates a valid link, presence of link activity, or a fault  
on the link.  
Table 2.12 LSI7202EP Link Activity/Link Fault LEDs  
Link  
Activity  
Fault  
LED Appearance  
Off  
Green Blinking  
Yellow  
Physical Characteristics  
Copyright © 2002 - 2005 by LSI Logic Corporation. All rights reserved.  
2-21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
2.8.13 LSI7402XP-LC Host Adapter Configuration  
The LSI Logic LSI7402XP-LC is a quad-channel, 2 Gbit/s FC adapter.  
Four LC optical connectors, used for I/O, are accessible through the  
module bracket. The LSI7402XP-LC uses two LSIFC929X devices,  
providing four Fusion-MPT channels.  
The LSI7402XP-LC is a PCI short card; the dimensions are  
6.875 inches x 4.2 inches. The external FC connections are made  
through the 2 Gbit/s SFP optical modules.  
The component height on the top and bottom of the board conforms to  
the PCI-X/133 Specification, Revision 1.0a. Figure 2.13 illustrates the  
major components on the LSI7402XP-LC.  
Figure 2.13 LSI7402XP-LC Host Adapter Configuration  
LSI7402XP-LC  
Flash  
(Back)  
SRAM  
(X2)  
LSIFC929X  
Port 3, SFP  
LSIFC929X  
Port 2, SFP  
Flash  
(Back)  
Port 1, SFP  
Port 0, SFP  
PCI-X Bridge  
Osc.  
Voltage  
Regulator  
SRAM (X2)  
J1_T  
2-22  
2 Gbit/s FC Host Adapter Characteristics  
Copyright © 2002 - 2005 by LSI Logic Corporation. All rights reserved.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
2.8.14 LSI7402XP-LC Connectors and Indicator LEDs  
The LSI7402XP-LC I/O bracket is configured as shown in Figure 2.14.  
The LC connector provides the connection from the adapter channel to  
the FC subsystem. The indicator LEDs indicate link status, activity, and  
link fault.  
Figure 2.14 LSI7402XP-LC Connectors and Indicator LEDs  
Port 3  
Port 2  
Port 1  
Port 0  
Port 2 LED  
Port 0 LED  
Port 3 LED  
Port 1 LED  
Table 2.13 describes the LSI7402XP-LC Link Activity/Link Fault LED  
appearance that indicates a valid link, presence of link activity, or a fault  
on the link.  
Table 2.13 LSI7402XP-LC Link Activity/Link Fault LEDs  
Link  
Activity  
Fault  
LED Appearance  
Off  
Green Blinking  
Yellow  
Physical Characteristics  
Copyright © 2002 - 2005 by LSI Logic Corporation. All rights reserved.  
2-23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
2.8.15 LSI7402EP-LC Host Adapter Configuration  
The LSI Logic LSI7402EP-LC is a quad-channel, 2 Gbit/s FC adapter.  
Four LC optical connectors, used for I/O, are accessible through the  
module bracket. The LSI7402EP-LC uses two LSIFC929X devices,  
providing four Fusion-MPT channels.  
The LSI7402EP-LC is a PCI short card; the dimensions are  
6.875 inches x 4.2 inches. The external FC connections are made  
through the 2 Gbit/s SFP optical modules.  
The component height on the top and bottom of the board conforms to  
the PCI Express Specification, Revision 1.0a. Figure 2.15 illustrates the  
major components on the LSI7402EP-LC.  
Figure 2.15 LSI7402EP-LC Host Adapter Configuration  
LSI7402EP  
Flash  
(Back)  
SRAM  
(X2)  
LSIFC929X  
Port 3, SFP  
LSIFC929X  
Port 2, SFP  
Flash  
(Back)  
Port 1, SFP  
Port 0, SFP  
PCI Express  
Bridge  
Osc.  
Voltage  
Regulator  
SRAM (X2)  
2-24  
2 Gbit/s FC Host Adapter Characteristics  
Copyright © 2002 - 2005 by LSI Logic Corporation. All rights reserved.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
2.8.16 LSI7402EP-LC Connectors and Indicator LEDs  
The LSI7402EP-LC I/O bracket is configured as shown in Figure 2.16.  
The LC connectors provide the connections from the adapter channels to  
the FC subsystem. The indicator LEDs indicate link status, activity, and  
link fault.  
Figure 2.16 LSI7402EP-LC Connectors and Indicator LEDs  
Port 3  
Port 2  
Port 1  
Port 0  
Port 2 LED  
Port 0 LED  
Port 3 LED  
Port 1 LED  
Table 2.14 describes the LSI7402EP-LC Link Activity/Link Fault LED  
appearance that indicates a valid link, presence of link activity, or a fault  
on the link.  
Table 2.14 LSI7402EP-LC Link Activity/Link Fault LEDs  
Link  
Activity  
Fault  
LED Appearance  
Off  
Green Blinking  
Yellow  
Physical Characteristics  
Copyright © 2002 - 2005 by LSI Logic Corporation. All rights reserved.  
2-25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
2.8.17 LSI7402EP Host Adapter Configuration  
The LSI Logic LSI7402EP is a quad-channel, 2 Gbit/s FC adapter. Four  
connectors, used for I/O, are accessible through the module bracket. The  
LSI7402EP uses two LSIFC929X devices, providing four Fusion-MPT  
channels.  
The LSI7402EP is a PCI short card; the dimensions are  
6.875 inches x 4.2 inches. The external FC connections are made  
through the 2 Gbit/s SFP optical modules.  
The component height on the top and bottom of the board conforms to  
the PCI Express Specification, Revision 1.0a. Figure 2.17 illustrates the  
major components on the LSI7402EP.  
Figure 2.17 LSI7402EP Host Adapter Configuration  
LSI7402EP  
Flash  
(Back)  
SRAM  
(X2)  
LSIFC929X  
Port 3, SFP  
LSIFC929X  
Port 2, SFP  
Flash  
(Back)  
Port 1, SFP  
Port 0, SFP  
PCI Express  
Bridge  
Osc.  
Voltage  
Regulator  
SRAM (X2)  
2-26  
2 Gbit/s FC Host Adapter Characteristics  
Copyright © 2002 - 2005 by LSI Logic Corporation. All rights reserved.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
2.8.18 LSI7402EP Connectors and Indicator LEDs  
The LSI7402EP I/O bracket is configured as shown in Figure 2.18. The  
Port 0, Port 1, Port 2, and Port 3 connectors provide the connections from  
the adapter channels to the FC subsystem. The indicator LEDs indicate  
link status, activity, and link fault.  
Figure 2.18 LSI7402EP Connectors and Indicator LEDs  
Port 3  
Port 2  
Port 1  
Port 0  
Port 2 LED  
Port 0 LED  
Port 3 LED  
Port 1 LED  
Table 2.15 describes the LSI7402EP Link Activity/Link Fault LED  
appearance that indicates a valid link, presence of link activity, or a fault  
on the link.  
Table 2.15 LSI7402EP Link Activity/Link Fault LEDs  
Link  
Activity  
Fault  
LED Appearance  
Off  
Green Blinking  
Yellow  
Physical Characteristics  
Copyright © 2002 - 2005 by LSI Logic Corporation. All rights reserved.  
2-27  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
2-28  
2 Gbit/s FC Host Adapter Characteristics  
Copyright © 2002 - 2005 by LSI Logic Corporation. All rights reserved.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 3  
Firmware Installation  
Procedure  
This chapter provides information about installing and configuring FC  
firmware and includes the following sections:  
Section 3.1, “FC Firmware”  
Section 3.2, “Download New FC Firmware”  
Section 3.3, “Update the FC Firmware”  
Section 3.4, “Advanced User: Adjusting Default Firmware Settings”  
Section 3.5, “Troubleshooting”  
The LSI Logic FC chips and host adapters contain firmware that presents  
a multiprotocol service layer based on the Fusion-MPT architecture. The  
FC firmware provides FCP (SCSI-3 over FC) Initiator, FCP Target, and  
LAN interface services to the host system.  
The FC929X.ROMfile contains the firmware to operate the LSIFC929X or  
LSIFC919X controllers used on the associated 2 Gbit/s LSI Logic host  
adapters. When updates are necessary, LSI Logic releases new firmware  
to improve the functionality or performance of these host adapters. You  
may download the latest firmware from the LSI Logic web site at:  
2 Gbit/s Fibre Channel Host Adapters User’s Guide  
Copyright © 2002 - 2005 by LSI Logic Corporation. All rights reserved.  
3-1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
3.1 FC Firmware  
This section includes the features, description, installation, and  
configuration of the FC firmware. The installation method varies  
depending on the operating system. LSI Logic provides firmware  
installation tools for the Windows, Linux, and Solaris operating systems.  
3.1.1 Features  
The FC firmware for the LSI Logic FC chips supports the  
following features:  
1 Gbit/s and 2 Gbit/s FC transfers, with AutoNegotiation  
(select 1 Gbit/s, 2 Gbit/s, or Auto)  
64-bit/66 MHz host PCI bus and 133 MHz PCI-X bus  
(backward-compatible with 32-bit/33 MHz)  
Transaction performance capability of > 70,000 I/Os per second  
(both channels)  
Throughput capability of ~400 Mbytes/s, across 64-bit/66 MHz PCI  
(both channels)  
Low host CPU utilization  
Interrupt coalescing, tunable to system requirements  
Auto Topology Detection for Arbitrated Loop, Fabric Loop, or  
Direct Fabric attachment (user selects N_Port, NL_Port, or Auto)  
FC Class 3 support  
FC-Tape/FC-AL2 Class 3 confirmed delivery support  
Fusion-MPT common software interface  
Initiator, Target, and FC LAN capability  
3.1.2 Description  
The LSIFC929X and LSIFC919X controllers operate in an environment  
where one or more host drivers serve as the interface layer between the  
operating system and the Fusion-MPT services provided by the  
LSI Logic FC firmware. The host driver is responsible for initializing the  
controller, building request message frames, issuing request message  
3-2  
Firmware Installation Procedure  
Copyright © 2002 - 2005 by LSI Logic Corporation. All rights reserved.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
frames to the controller, and processing reply message frames received  
from the controller.  
The LSI Logic firmware translates Fusion-MPT message frames into  
FC-specific sequences, frames, and primitives that are delivered to the  
FC transmit and receive physical interfaces. The firmware-based  
Link Services library transparently provides all link service support that the  
host uses for all FC topologies. The firmware also manages all link  
exceptions, which isolates the host driver from FC-unique exceptions. With  
the Fusion-MPT architecture, parallel SCSI host drivers can be used with  
the LSI Logic FC controllers with little or no additional functionality for FC.  
3.2 Download New FC Firmware  
To begin, you must first download new host adapter firmware  
component(s) from the LSI Logic web site (www.lsilogic.com). Type the  
following address into your preferred browser:  
The web page presents three drop-down menus under Find Specific  
Products. Make the following selections:  
Step 1. Select Storage Adapters.  
Step 2. Select Fibre Channel HBAs.  
Step 3. Select LSI7202XP-LC (or other 2 Gbit/s LSI Logic host  
adapter).  
Step 4. Check the box next to BIOS/Firmware. Then click the Go  
button.  
This search locates the latest BIOS/Firmware available for your host  
adapter. Save the file to your hard drive. You may have to unzip this file.  
Typically, the download will contain three separate files:  
FC929X.ROM —LSI Logic Firmware update  
MPTBIOS.ROM —LSI Logic Boot BIOS update  
LSI9x9f.ROM —LSI Logic Fcode update  
Download New FC Firmware  
Copyright © 2002 - 2005 by LSI Logic Corporation. All rights reserved.  
3-3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
These files represent updated code that you may store on your LSI Logic  
host adapter using one of the methods described in the next sections.  
3.3 Update the FC Firmware  
The process of updating the FC firmware varies slightly, depending on  
the operating system.  
3.3.1 GUI Update Tool for Windows and Linux Platforms  
With the MyStorage™ management software installed on either Windows  
or Linux operating systems, you can use the MyStorage software to  
update LSI Logic host adapters with new firmware (Section 3.2,  
“Download New FC Firmware”). The CD-ROM media distributed with  
many LSI Logic host adapter kits contains the MyStorage software;  
alternatively, users can download the MyStorage software from the  
LSI Logic web site (www.lsilogic.com).  
Refer to LSI Logic MyStorage Management Software User’s Guide for  
detailed usage instructions.  
3.3.2 Command Line Update Tool for Solaris, Linux, and Windows  
LSI Logic provides a FC Flash command line utility called LSIUtil to  
update LSI Logic host adapters with new firmware (Section 3.2). The  
software is available for the Windows, Linux, and Solaris operating  
systems. This section provides the procedure for operating this program.  
Note:  
The LSIUtil program will not operate properly unless an  
LSI Logic OS driver is also installed.  
Running the LSIUtil Program – The LSIUtil program may be used to  
update the LSI Logic FC firmware of any 2 Gbit/s host adapter. Locate  
and copy the LSIUtil.exe program and the FC929X.ROM code files  
to a directory on your hard drive. To update the firmware, complete the  
following steps:  
Step 1. Ensure that the host adapter is properly installed in the system  
PCI/PCI-X or PCI Express slot.  
3-4  
Firmware Installation Procedure  
Copyright © 2002 - 2005 by LSI Logic Corporation. All rights reserved.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Step 2. Open a terminal window, and open the directory containing the  
LSIUtil program.  
Step 3. Execute the LSIUtil program.  
Step 4. Select a device to update (Figure 3.1).  
Figure 3.1 LSIUtil Device Selection  
[root]# lsiutil  
LSI Logic MPT Configuration Utility, Version 1.28, November 12,  
2004  
2 MPT Ports found  
Port Name  
2. /proc/mpt/ioc1  
Chip Vendor/Type  
LSI Logic FC929X  
MPT Rev  
103  
Firmware Rev  
01021200  
Select a device: [1-2 or 0 to quit]  
Step 5. From the subsequent displayed list, select option menu 2 or 4  
as shown (Figure 3.2).  
Update the FC Firmware  
Copyright © 2002 - 2005 by LSI Logic Corporation. All rights reserved.  
3-5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Figure 3.2 LSIUtil Download Options  
Step 6. When prompted, type the firmware file name.  
Step 7. Type Yes, when asked to continue (Figure 3.3).  
Figure 3.3 LSIUtil File Download  
Enter firmware name: FC929X.ROM  
Do you want to continue? [Yes or No, default is No] Y  
Downloading image...  
Download succeeded  
The update process requires about 20–30 seconds. Upon completion,  
the system should display this message: “download succeeded”.  
Step 8. Reset the adapter using option 99, or reboot to begin running  
the new firmware.  
Step 9. Enter 0 to quit the program.  
3-6  
Firmware Installation Procedure  
Copyright © 2002 - 2005 by LSI Logic Corporation. All rights reserved.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
3.3.3 Command Line Update Tool for DOS  
Using a DOS bootable floppy, users can use a FC Flash Utility called  
MPTUtilto update LSI Logic adapters with new firmware (Section 3.2,  
“Download New FC Firmware,page 3-3). This section provides the  
procedure for operating this program.  
Note:  
The MPTUtil program will not operate properly from a  
windows command window. It must be run from a DOS  
floppy.  
Running the MPTUtil Program – Use the MPTUtil program to  
update the LSI Logic FC firmware on any 4 Gbit/s host adapter. Locate  
the MPTUtil.exe program and FC929X.ROM code on your  
distribution media, as well as the DOS4GW.exe file. Copy these files to  
a blank, formatted diskette. Label it “FC Firmware diskette.”  
To update the firmware, complete the following steps:  
Step 1. Ensure that the host adapter is properly installed in the system  
PCI slot.  
Step 2. Insert the LSI Logic FC firmware diskette into drive A.  
Step 3. Boot the system to the DOS prompt A:\>.  
Step 4. Execute the MPTUtil program directly from the DOS command  
line by typing at the prompt:  
A:\ MPTutil  
The MPTUtil program identifies all LSI Logic host adapters in the system,  
and it allows you to select which adapter to update (Figure 3.4).  
Figure 3.4 MPTUtil Device Selection  
LSIMPTUTIL 1.00.00  
Vendor Device  
Choice ID  
ID  
Bus Device  
------ ------ ------ --- ----------  
1
Adapter  
2
1000h  
0626h  
0h  
28h LSI 929X Fibre Channel Host  
Refresh  
Which chip (0 to quit)? __  
Update the FC Firmware  
Copyright © 2002 - 2005 by LSI Logic Corporation. All rights reserved.  
3-7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Step 5. The MPTUtil program displays a menu of options (Figure 3.5).  
To update the firmware, select option a - Update Firmware.  
Figure 3.5 MPTUtil Options  
LSI Logic Corp. FC/SAS Serial EEPROM / FLASH Utility.  
LSIMPTUTIL 1.00.00  
Copyright (c) 2005 LSI Logic Corporation. All rights reserved.  
*******************************************************************  
Currents  
Port 0  
Port 1  
0x100000062B092449  
0x200000062B092449  
World Wide P/N... 0x100000062B092448  
World Wide P/N... 0x200000062B092448  
Topology......... Auto  
Speed............ Auto  
Device Pathing... All Paths to a device  
Protocol Support. INIT TARG LAN  
Firmware: LSIFC929X 1.02.12 (2005.06.15)  
********************************************************************  
a - Update Firmware  
b - Update BIOS & Firmware  
c - Upload current firmware to a file  
d - Upload current BIOS to a file  
f - Toggle Board Speed on Function 0  
g - Toggle Board Speed on Finction 1  
f - Toggle Topologies on Function 0  
g - Toggle Topologies on Finction 1  
l - Change Interrupt Coalescing Values on Port 0  
m - Change Interrupt Coalescing Values on Port 1  
x - Erase BIOS  
y - Change Protocol Support  
z - Change Adapters  
q - Quit  
Selection:  
Step 6. When prompted, type the filename of the BIOS/Fcode update.  
The update process commences and completes in about 20–  
30 seconds.  
Step 7. Exit the MPTUtil utility using the menu option q - Quit.  
3.4 Advanced User: Adjusting Default Firmware Settings  
Occasionally, a user may find it necessary to adjust default firmware  
parameters set by LSI Logic during the original manufacturing process.  
Adjustments to these parameters will affect future behavior of the  
3-8  
Firmware Installation Procedure  
Copyright © 2002 - 2005 by LSI Logic Corporation. All rights reserved.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
LSI Logic Adapter, and should be reserved for advanced users who fully  
understand the implications of such changes.  
The LSI Logic firmware supports several configuration options, defined  
individually in Section 3.4.1, “Adjusting Link Speed,and Section 3.4.2,  
“Adjusting Interrupt Coalescing.These options may be configured using  
the MPTUtil utility menu, as described in the subsection entitled  
“Running the MPTUtil Program”.  
3.4.1 Adjusting Link Speed  
The link speed of the LSI Logic host adapters is configurable. By default,  
the link speed is set to Auto. This means the host adapter automatically  
detects the link speed of all other nodes on the link and automatically  
adjusts itself to work with those nodes. If this automatic operation fails  
(for example, other nodes on a loop do not support AutoNegotiation), the  
LSI Logic host adapters may be configured specifically to either the 2  
Gbit/s or 1 Gbit/s speed.  
Note:  
The LSI7202XP-LC, LSI7202EP-LC, and LSI7202EP each  
have two FC ports and the LSI7402XP-LC, LSI7402XP-LC,  
and LSI7402XP-LC each have four FC ports, so the link  
speed must be configured for each port. The  
LSI7102XP-LC has only one port.  
Configure the link speed of the host adapter by following these steps:  
Step 1. To set the link speed of the host adapter, execute this command  
from the DOS command line:  
A:\ MPTutil  
The MPTUtil program identifies all LSI Logic host adapters in  
the system, and allows you to select which adapter to update  
(Figure 3.4).  
Step 2. The MPTUtil program displays a menu of options. (Figure 3.5).  
To change the link speed on the LSI7202XP-LC Port 0 (lower  
port, near the PCI connector), select the following menu option:  
f - Toggle Board Speed on Function 0  
To change the link speed on the LSI7202XP-LC Port 1 (upper  
port from the PCI connector), select the following menu option:  
Advanced User: Adjusting Default Firmware Settings  
Copyright © 2002 - 2005 by LSI Logic Corporation. All rights reserved.  
3-9  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
g - Toggle Board Speed on Function 1  
Successively pressing the F key (for Function 0) or the G key  
(for Function 1) toggles the PORT speed setting between these  
three modes:  
AUTO  
1 Gbit/s  
2 Gbit/s  
Step 3. Exit the FCUtil utility using the menu option q - Quit.  
3.4.2 Adjusting Interrupt Coalescing  
The LSI Logic host adapters can complete multiple I/O requests per host  
interrupt. Interrupt coalescing is used to reduce CPU interrupts by  
pooling multiple disk command completions (I/O) into one interrupt. This  
feature may be enabled or disabled.  
Important: LSI Logic has performed significant testing under multiple  
I/O conditions and has determined that interrupt coalescing  
can be very valuable for small transfer lengths or random,  
transaction-oriented I/O workloads. For this type of  
workload, LSI Logic recommends that the Interrupt  
Coalescing values be set to a queue depth of 9, with a  
timeout of 1280 (0x500) µs. This means that the host is  
interrupted only once for 9 I/Os processed by the chip,  
unless 1280 µs have passed since the host was last  
interrupted. If the workload is of a large transfer length and  
sequential, LSI Logic recommends that interrupt coalescing  
be disabled to prevent performance degradation.  
Note:  
The LSI7202XP-LC, LSI7202EP-LC, and LSI7202EP each  
have two FC ports and the LSI7402XP-LC, LSI7402XP-LC,  
and LSI7402XP-LC each have four FC ports, so Interrupt  
Coalescing must be configured for each port. The  
LSI7102XP-LC has only one port.  
Use the following procedure to adjust Interrupt Coalescing depth and  
timeout values:  
Step 1. To set the link speed of the host adapter, execute this command  
from the DOS command line:  
3-10  
Firmware Installation Procedure  
Copyright © 2002 - 2005 by LSI Logic Corporation. All rights reserved.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
A:\ Mptutil  
The MPTUtil program identifies all LSI Logic host adapters in  
the system, and allows you to select which adapter to update.  
(See Figure 3.4.)  
Step 2. The MPTUtil program displays a menu of options. (See  
Figure 3.5.)  
To change Interrupt Coalescing on the LSI7202XP-LC Port 0,  
select the following menu option:  
1- Change Interrupt Coalescing Values on Port 0  
The current values are displayed within a submenu that allows the values  
to be changed (Figure 3.6).  
Figure 3.6 Interrupt Coalescing Values  
Flags – By default, the host adapter has Interrupt Coalescing enabled,  
as indicated by the Flags value of 0x0001. If you want to disable Interrupt  
Coalescing, enter a value of 0x0000 for Flags. Interrupt Coalescing  
should only be disabled to resolve issues in unique system  
configurations. Consult LSI Logic Host Adapter Support to verify the  
need to disable Interrupt Coalescing for specific system configurations.  
When enabled, two parameters are relevant for interrupt coalescing:  
Coalescing Depth – Specifies the number of I/Os that must complete  
before a host interrupt is generated. For example, if set to 4, then the  
adapter waits until four I/Os complete before notifying the host CPU via  
the interrupt mechanism. You can decrease this value to improve system  
performance if the system contains lower performance servers and/or  
peripherals.  
Coalescing Timeout This is failsafe time period that specifies the  
maximum amount of time (in milliseconds) to interrupt regardless of  
Coalescing depth.  
Advanced User: Adjusting Default Firmware Settings  
Copyright © 2002 - 2005 by LSI Logic Corporation. All rights reserved.  
3-11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
3.5 Troubleshooting  
Some potential problems and their suggested solutions are as follows:  
The firmware and BIOS revisions typically must be in sync for  
proper operation.  
Check with LSI Logic Technical Support to make sure that the Firmware  
is the correct version to use with your BIOS. If the firmware revision is  
not in sync with the BIOS revision, system failures may occur.  
How do you identify the version number of the firmware?  
The UNIX-compatible WHAT.EXE program for DOS included on your  
distribution media can identify the ROM files on the diskette(s).  
Examples:  
what *.*  
what *.* nt/*.*  
Many types of errors are reported through the LED on the LSI Logic  
Host Adapter boards.  
When these errors occur, the LED flashes a four-digit sequence, which  
is the error code. These types of errors should be reported to LSI Logic  
Technical Support. The technical support representative will ask for  
additional system configuration information, including the type of system  
used, the FC configuration and type of peripherals (including version  
numbers), and the sequence of events when the error occurred.  
3-12  
Firmware Installation Procedure  
Copyright © 2002 - 2005 by LSI Logic Corporation. All rights reserved.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Chapter 4  
BIOS Features  
This chapter describes the Fibre Channel (FC) BIOS and  
Configuration Utility and includes the following sections:  
Section 4.1, “LSI Logic Boot BIOS”  
Section 4.2, “Starting the LSI Logic Boot BIOS Configuration Utility”  
Section 4.3, “Using the LSI Logic Boot BIOS CU”  
Section 4.4, “Main Menu”  
Section 4.5, “Exiting the LSI Logic Boot BIOS Configuration Utility”  
Section 4.6, “Troubleshooting”  
Section 4.7, “OpenBoot BIOS”  
A BIOS is the ROM code that the system loads to facilitate booting from  
FC drives. The BIOS also contains an embedded configuration manager,  
with which you configure options provided by the firmware. The LSI Logic  
BIOS integrates with a standard system BIOS, extending the standard  
disk service routine provided through INT13h.  
Two types of BIOS are available for the LSI Logic host adapters:  
LSI Logic FC boot BIOS for Intel/AMD-based platforms, and  
LSI Logic FC OpenBoot BIOS for Solaris SPARC platforms.  
Both the LSI Logic boot BIOS and OpenBoot BIOS are stored on the FC  
host adapter boards.  
2 Gbit/s Fibre Channel Host Adapters User’s Guide  
Copyright © 2002 - 2005 by LSI Logic Corporation. All rights reserved.  
4-1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
4.1 LSI Logic Boot BIOS  
This section provides the features, description, and installation of the  
LSI Logic FC boot BIOS.  
4.1.1 LSI Logic Boot BIOS Features  
The LSI Logic FC boot BIOS supports:  
Selection and configuration for up to 256 adapters  
Boot device selection from any four host adapters  
Automatic INT13 drive mapping for FC drives  
4.1.2 BIOS Overview  
If Boot is enabled, the boot BIOS scans for FC Hard disks connected to  
the FC host adapter. All discovered disks are enumerated with drive  
letters and appended to a master list of disks discovered on the host.  
Upon scan completion, the host serially inspects the master list of disks  
beginning with drive letter A and attempts to boot from the first device it  
finds with a boot record. If boot from FC is desired, you may elect to  
remove or disable IDE drives, as these tend to get lower drive letter  
assignments than FC devices.  
Note:  
The Boot feature is disabled by default on all host adapters  
shipped from LSI Logic.  
4.1.3 LSI Logic BIOS Boot Specification (BBS)  
The LSI Logic BIOS provides support for the BIOS Boot Specification  
(BBS), which allows you to choose which device to boot from by  
selecting the priority.  
To use this feature, the system BIOS must be compatible with the BBS.  
If your system supports the BBS, use the system BIOS setup menu to  
select the boot and drive order. In the system BIOS setup, the Boot  
Connection Devices menu appears with a list of available boot options.  
Use that menu to select the device and rearrange the order. Then exit to  
continue the boot process.  
4-2  
BIOS Features  
Copyright © 2002 - 2005 by LSI Logic Corporation. All rights reserved.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
4.2 Starting the LSI Logic Boot BIOS Configuration Utility  
The LSI Logic boot BIOS allows you to change the default configuration  
of your host adapters, using the embedded BIOS Configuration Utility  
(CU).  
When the BIOS loads, the following message appears on your monitor:  
Press Ctrl-C to start LSI Logic Configuration Utility...  
This message remains on your screen for about five seconds, giving you  
time to start the utility. After you press CTRL+C, the message changes  
to:  
Please wait, invoking LSI Logic Configuration Utility...  
After a brief pause, your computer monitor displays the Main menu of the  
BIOS CU.  
Note:  
Not all devices detected by the CU can be controlled by the  
BIOS. Devices such as tape drives and scanners require  
loading a device driver specific to that peripheral. The BIOS  
CU allows parameters to be modified for these devices.  
4.3 Using the LSI Logic Boot BIOS CU  
This section provides the menu formats and user inputs available to inform  
users about the boot BIOS CU prior to running it. All BIOS CU screens  
that display various menus are partitioned into fixed areas. This area  
provides static general help text information.  
4.4 Main Menu  
When you invoke the LSI Logic boot BIOS CU, the Main menu appears.  
This screen displays a scrolling list of up to 256 host adapters in the  
system and information about each of them.  
Use the arrow keys to highlight a host adapter. Then press ENTER to  
view and modify the selected host adapter properties (and to gain access  
to the attached devices). After selecting an adapter and pressing  
Starting the LSI Logic Boot BIOS Configuration Utility  
Copyright © 2002 - 2005 by LSI Logic Corporation. All rights reserved.  
4-3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
ENTER, the FC Link bus is scanned and the Adapter Properties screen  
appears.  
On the Main menu, two selections are the Boot Adapter List and  
Global Properties menus.  
Boot Adapter List allows selection and ordering of boot adapters. Refer  
to Section 4.4.4, “Boot Adapter List Menu,for details.  
Global Properties allows changes to global scope settings. Refer to  
Section 4.4.5, “Global Properties Menu,for details.  
Only host adapters with LSI Logic Control enabled can be accessed.  
4.4.1 Adapter Properties Menu  
The Adapter Properties menu allows you to view and modify adapter  
settings. It also provides access to the device settings of a host adapter.  
To display this menu, select a device under the Adapter field on the  
Main menu and press ENTER.  
4.4.2 Persistent ID Menu  
You can use the Persistent ID menu simply to review the automatic  
mapping between a drive World Wide Name (WWN) and its assigned  
logical SCSI bus and Target ID. The screen also can force a drive to a  
specific logical Target ID.  
Selecting Add WWN at an unused location clears out the associated  
WWN/DID field and allows you to enter the first 16 characters of the  
WWN. Pressing ENTER afterwards allows the last 16 characters to be  
entered. The Configuration Utility automatically adds any leading zeros,  
if necessary. If an entry was put in by mistake, selecting Erase on the  
appropriate line removes the entry.  
Logical ID selection defaults to be the lowest ID available. This can be  
changed by using the PLUS or MINUS keys to cycle the numbers. The  
Bus field always defaults to 0 and cannot be changed. It is displayed  
whenever an outside utility has reserved a different number.  
The Next Page and Previous Page options are provided on the persistent  
ID screens through the F2 key, which moves the screen forward or back  
by 16 entries. However, the CU requires storing any modifications to the  
4-4  
BIOS Features  
Copyright © 2002 - 2005 by LSI Logic Corporation. All rights reserved.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
current page before new entries may be viewed or modified. A pop-up  
confirmation window asks to store or discard changes, if needed.  
4.4.3 Device Properties Menu  
The Device Properties menu allows you to view and update individual  
device settings for an adapter.  
Note:  
The number of fields on the menu requires that you scroll  
left/right to view all the information. When accessing this  
menu, use the HOME and END keys to scroll to columns  
currently not displayed. The scroll indicator on the bottom  
of the menu shows the position of the cursor relative to the  
first and last columns.  
4.4.4 Boot Adapter List Menu  
The Boot Adapter List menu specifies the order in which adapters boot  
when more than one LSI Logic host adapter is in a system. Up to four  
adapters in a system can be selected as bootable. Only one of the four  
bootable adapters can control a boot volume.  
To select this menu:  
1. Press F2 while on the Main menu to move the cursor to the menu  
area.  
2. Move the cursor to Boot Adapter List with the arrow keys.  
3. Press ENTER.  
Adapters can be added or deleted using this menu. To add an adapter  
to the boot list, press the INSERT key while on the Boot Adapter List.  
Use the arrow keys to select the desired adapter, and press ENTER to  
add it to the end of the Boot Adapter List.  
To remove an adapter from the boot list, press the DELETE key while  
the desired adapter is selected in the Boot Adapter List. You can also  
change the boot order by using the PLUS or MINUS keys. For example,  
place the cursor on the adapter that you want to change, and use the  
PLUS or MINUS key to raise or lower the boot order, respectively.  
Main Menu  
4-5  
Copyright © 2002 - 2005 by LSI Logic Corporation. All rights reserved.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
4.4.5 Global Properties Menu  
The Global Properties menu allows you to pause if an alert message has  
been displayed, to view display boot information, and to set display and  
video modes.  
4.5 Exiting the LSI Logic Boot BIOS Configuration Utility  
The Exit menu for the LSI Logic boot BIOS configuration utility is used  
for all six of the menus listed in Section 4.4, “Main Menu,page 4-3.  
However, the available functionality is different for the Main menu and the  
five subordinate menus.  
To exit from the Adapter Properties, Persistent ID, Device Properties,  
Boot Adapter List, or Global Properties menus, use the following  
exit options:  
Cancel exit  
Returns you to the previous menu.  
Save changes then  
exit this menu  
Implements any changes you made on the previous  
menu and returns you to the Main menu.  
Discard changes  
then exit this menu  
Restores the default settings and returns you to the  
Main menu.  
To exit from the Main menu, use the following exit options:  
Cancel exit  
Returns you to the Main menu.  
Exit the Configuration Exits the configuration and automatically reboots your  
Utility system.  
Important: If you reboot the system without properly exiting from this  
utility, some changes may not take effect.  
4.6 Troubleshooting  
The LSI Logic boot BIOS Configuration Utility is a powerful tool. If you  
disable all of your controllers while using it, pressing CTRL+A or  
4-6  
BIOS Features  
Copyright © 2002 - 2005 by LSI Logic Corporation. All rights reserved.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
CTRL+E after memory initialization during reboot. This allows you to re-  
enable and reconfigure.  
The following messages may appear during the boot process:  
Adapter removed from boot order, parameters will be  
updated accordingly!appears when an adapter is removed from  
the system or is relocated behind a PCI bridge. This message is for  
information only, and no further user action is required.  
Configuration data invalid, saving default configuration!  
appears if none of the information in nonvolatile random access  
memory (NVRAM) is valid. This message is for information only and  
can occur when the BIOS is upgraded or when some external event  
has rendered the NVRAM temporarily unreadable.  
Found FC Controller not in following Boot Order List, to  
Add: Press Ctrl-C to start LSI Logic Configuration  
Utility... appears when fewer than four adapters are in the boot  
order and adapters exist in the system that are not in the boot order.  
This message is for information only and indicates that more than  
four adapters exist in the system. The additional adapters are not  
managed by the CU.  
4.7 OpenBoot BIOS  
LSI Logic Solaris-capable, Fusion-MPT host adapters have Fcode  
resident on board, allowing operation under the Sun Microsystems  
OpenBoot console. All basic functionality is available in an OpenBoot  
environment, including the ability to display devices connected to the  
adapter and to boot devices on the adapter.  
4.7.1 OpenBoot BIOS Features  
The LSI Logic FC OpenBoot BIOS supports the following:  
Solaris SPARC 2.6, Solaris SPARC 2.7, and Solaris 8 Open Firmware  
environments  
Root Boot device selection from any target device  
Standard command line interface, with help query  
Configuration options and selection capability for each host adapter  
OpenBoot BIOS  
Copyright © 2002 - 2005 by LSI Logic Corporation. All rights reserved.  
4-7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
4.7.2 Identifying the FC Devices  
The probe-scsi-all command identifies the FC devices on your Fusion-  
MPT adapter.  
To show all disks available from the OpenBoot prompt, use the  
probe-scsi-all command. Note that this command is used regardless of  
whether the disks are FC or SCSI. All disks available on all Fusion-MPT  
devices are displayed.  
The following example shows the kind of information that is displayed  
when you enter this command.  
ok probe-scsi-all  
/pci@8,600000/SUNW,qlc@4  
LiD HA LUN ---Port WWN--- ----Disk description----  
1 1 0 2100002037e4d65b SEAGATE ST318304FSUN18G 0726  
/pci@8,700000/IntraServer-Ultra160,scsi@3,1  
/pci@8,700000/IntraServer-Ultra160,scsi@3  
Target 0  
Unit 0 Disk IBM DDRS-34560D DC1B  
/pci@8,700000/IntraServer,fc@2  
MPT Version 1.00, Firmware Version 1.02.00  
Target 0  
Unit 0 Disk SEAGATE ST39173FC 6615  
WWN 2100002037109d76 Port ID d9  
Target 1  
Unit 0 Disk SEAGATE ST39173FC 6258  
WWN 210000203710565a Port ID 17  
Target 2  
Unit 0 Disk SEAGATE ST39173FC 6258  
WWN 2100002037105212 Port ID 1  
Target 3  
Unit 0 Disk SEAGATE ST39173FC 6258  
WWN 2100002037103da8 Port ID 26  
4-8  
BIOS Features  
Copyright © 2002 - 2005 by LSI Logic Corporation. All rights reserved.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Target 4  
Unit 0 Disk SEAGATE ST39173FC 6258  
WWN 210000203710324a Port ID 73  
/pci@8,700000/scsi@6  
Target 6  
Unit 0 Removable Read Only device PLEXTOR CD-ROM PX-20TS  
If the FC devices on your IntraServer™ adapter are not identified by your  
system, check the following:  
Is the FC enclosure powered on?  
Does the LED on the adapter indicate Link? (Note that Link is valid  
only after the device is probed.)  
Does the LED on the switch or remote enclosure indicate Link?  
Does the Link-SPEED parameter selected by the adapter match that  
of the bus (1G, 2G, or Auto)?  
If you do not see disks, the following additional debug information may  
help to identify the problem.  
4.7.3 Verifying Installation  
Use the following procedure to verify installation of your Fusion-MPT  
adapter in the system:  
Step 1. Power-up the system.  
Step 2. When the banner is displayed, press the STOP+A keys to  
interrupt the boot process and stop at the ok prompt.  
Step 3. Use the show-devs command to list the system devices. You  
should see an output similar to the following:  
ok show-devs  
/SUNW,UltraSPARC-III@0,0  
/virtual-memory  
/memory@m0,0  
/aliases  
/options  
/openprom  
/chosen  
/packages  
OpenBoot BIOS  
Copyright © 2002 - 2005 by LSI Logic Corporation. All rights reserved.  
4-9  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
/upa@8,480000/SUNW,ffb@0,0  
...  
/pci@8,700000/IntraServer,fc@2  
/pci@8,700000/IntraServer,fc@1,1  
/pci@8,700000/IntraServer,fc@1  
...  
/pci@8,700000/IntraServer,fc@2/disk  
/pci@8,700000/IntraServer,fc@2/tape  
/pci@8,700000/IntraServer,fc@1,1/disk  
/pci@8,700000/IntraServer,fc@1,1/tape  
/pci@8,700000/IntraServer,fc@1/disk  
/pci@8,700000/IntraServer,fc@1/tape  
/pci@8,700000/scsi@6,1/tape  
/pci@8,700000/scsi@6,1/disk  
ok  
/pci@8,700000/IntraServer,fc@1  
identifies the first FC interface on an LSIFC929X-based adapter.  
/pci@8,700000/IntraServer,fc@1,1  
identifies the second FC interface on an LSIFC929X-based adapter.  
An LSIFC919X-based adapter shows only one such FC device.  
Note:  
The above listing is an example. The show-devs output  
may vary depending on your system and configuration. Use  
the corresponding entries on your system, not the ones  
given here.  
If these devices are not listed, check to assure that the adapter is  
correctly installed and reseat the adapter in the PCI slot if necessary.  
4.7.4 Adapter-Specific Settings  
In certain circumstances, advanced users may want to change settings  
for an individual adapter or port, without affecting the other adapters in  
the system. Specific examples of such settings are FC bus speed, host  
adapter ID (SCSI only: not applicable to FC), and Interrupt Coalescing.  
To select a specific Fusion-MPT adapter as the current adapter, use the  
select command. Selecting a port or adapter brings the port online and  
allows you to show or set certain adapter specific parameters.  
4-10  
BIOS Features  
Copyright © 2002 - 2005 by LSI Logic Corporation. All rights reserved.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
You should use caution while issuing the following commands because  
some commands (such as forcing 1 Gbit/s operation on a 2 Gbit/s FC loop)  
could render the bus unusable.  
4.7.4.1  
4.7.4.2  
select Command  
Use the select OpenBoot command to choose the adapter entry. This  
opens the port to bring the port online.  
ok select /pci@8,700000/IntraServer,fc@1  
.properties Command  
Use the .properties command to show the adapter properties.  
ok .properties  
firmware-version 1.02.00  
mpt-version  
1.00  
scsi-initiator-id 00 00 00 0f  
assigned-addresses81001010 00000000 00000700 00000000 00000100  
83001014 00000000 001a0000 00000000 00020000  
8300101c 00000000 00190000 00000000 00010000  
82001030 00000000 02000000 00000000 00100000  
compatible  
model  
reg  
70 63 69 31 33 65 39 2c 36 32 31 00 70 63 69 31  
LSI,929  
00001000 00000000 00000000 00000000 00000000  
01001010 00000000 00000000 00000000 00000100  
03001014 00000000 00000000 00000000 00020000  
0300101c 00000000 00000000 00000000 00010000  
02001030 00000000 00000000 00000000 00100000  
1.00.16  
version  
device_type  
name  
scsi-2  
IntraServer,fc  
fcode-rom-offset 00000000  
66mhz-capable  
devsel-speed  
class-code  
interrupts  
latency-timer  
cache-line-size  
max-latency  
min-grant  
00000001  
00010000  
00000001  
00000040  
00000010  
00000008  
0000001e  
00000621  
subsystem-id  
subsystem-vendor-id000013e9  
revision-id  
device-id  
vendor-id  
00000001  
00000621  
00001000  
OpenBoot BIOS  
Copyright © 2002 - 2005 by LSI Logic Corporation. All rights reserved.  
4-11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4.7.4.3  
show-children Command  
While you have the host adapter or port selected, use the show-children  
command to display the devices currently connected to this adapter.  
First, select the port or adapter shown (use the port name your  
system assigns):  
ok select /pci@8,700000/IntraServer,fc@1  
ok show-children  
MPT Version 1.00, Firmware Version 1.02.00  
Link is ready, port is online  
WWN 100000a0b8040353 Port ID ef  
Target 0  
Unit 0 Disk SEAGATE ST39173FC 6615  
WWN 2100002037109d76 Port ID d9  
Target 1  
Unit 0 Disk SEAGATE ST39173FC 6258  
WWN 210000203710565a Port ID 17  
Target 2  
Unit 0 Disk SEAGATE ST39173FC 6258  
WWN 2100002037105212 Port ID 1  
Target 3  
Unit 0 Disk SEAGATE ST39173FC 6258  
WWN 2100002037103da8 Port ID 26  
Target 4  
Unit 0 Disk SEAGATE ST39173FC 6258  
WWN 210000203710324a Port ID 73  
4-12  
BIOS Features  
Copyright © 2002 - 2005 by LSI Logic Corporation. All rights reserved.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4.7.5 Interrupt Coalescing  
The LSI Logic host adapters can complete multiple I/O requests per host  
interrupt. Interrupt coalescing is used to reduce CPU interrupts by  
pooling multiple disk command completions (I/O) into one interrupt. This  
feature may be enabled or disabled.  
LSI Logic has performed significant testing under multiple I/O conditions  
and has determined that interrupt coalescing can be very valuable for  
small transfer lengths or random, transaction-oriented I/O workloads. For  
this type of workload, LSI Logic recommends that the Interrupt  
Coalescing values be set to a queue depth of 9, with a timeout of 1280  
(0x500) µs. This means that the host is interrupted only once for 9 I/Os  
processed by the chip, unless 1280 µs have passed since the host was  
last interrupted. If the workload is of a large transfer length and  
sequential, LSI Logic recommends that interrupt coalescing be disabled  
to prevent performance degradation.  
Although LSI Logic has determined that these settings are optimal for a  
wide variety of situations, your own I/O load may benefit from a deeper  
queue or a longer timeout. LSI Logic provides a mechanism to modify  
these values and write them to the nonvolatile EEPROM on the adapter.  
Select the port or adapter shown (use the port name your system assigns):  
ok select /pci@8,700000/IntraServer,fc@1  
Then enter commands as shown in the following example:  
ok show-interrupt-coalescing  
Interrupt coalescing timeout is 500 (1280 decimal)  
microseconds  
Interrupt coalescing depth is 9 (9 decimal)  
ok set-interrupt-coalescing  
Note:  
The OpenBoot BIOS provides help when you enter a  
command that does contain the proper arguments. In this  
case, OpenBoot responds with:  
usage is <timeout><depth> set-interrupt-coalescing  
ok 100 8 set-interrupt-coalescing  
OpenBoot BIOS  
Copyright © 2002 - 2005 by LSI Logic Corporation. All rights reserved.  
4-13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Interrupt coalescing timeout selected is 100 (256 decimal)  
microseconds  
Interrupt coalescing depth selected is 8 (8 decimal)  
Interrupt coalescing has been set  
Change will take effect after system reset  
Note:  
The system must be power cycled before the changes take  
effect. It is not sufficient to execute the reset-all command.  
4.7.6 Set FC Link Speed  
There are two modes of operation for FC: 1 Gbit/s and 2 Gbit/s. It is  
important to match the speed of the port with the speed of the loop or  
fabric to which the port is attached.  
LSI Logic has implemented autonegotiation on the 2 Gbit/s-capable,  
Fusion-MPT devices. If you are experiencing difficulty with the  
AutoNegotiate algorithm on your fabric or loop, or if you wish to set or  
show the link speed for the adapter manually, use the following  
procedure:  
Select the port or adapter shown (use the port name your system assigns):  
ok select /pci@8,700000/IntraServer,fc@1  
Then enter commands as shown in the following example:  
ok show-link-speed  
Link speed selected is 1 Gbaud  
Current link speed is 1 Gbaud  
ok set-link-speed  
Note:  
The OpenBoot BIOS provides help when you enter a  
command that does contain the proper arguments. In this  
case, OpenBoot responds with:  
usage is <link-speed> set-link-speed  
ok a set-link-speed  
Link speed selected is autobaud  
Link speed has been set  
Change will take effect after system power cycle  
4-14  
BIOS Features  
Copyright © 2002 - 2005 by LSI Logic Corporation. All rights reserved.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
ok show-link-speed  
Link speed selected is autobaud  
Current link speed is 1 Gbaud  
Note:  
The system must be power-cycled before the changes take  
effect. It is not sufficient to execute the reset-all command.  
4.7.7 Persistent Device Naming  
One of the most powerful benefits of storage area networks (SANs) is  
scalability; the freedom to quickly add or delete storage components. To  
facilitate trouble-free SAN reconfigurations, you can save a list of devices  
currently connected to the host adapter. Later, if certain devices are  
powered off, the adapter ensures that the remaining devices appear at  
the same mount point. Technically, the LSI Logic host adapter “locks” the  
association of an FC target with an alias name reference. The LSI Logic  
host adapter manages the details. When you mark a device persistent,  
mapping information is saved on the LSI Logic host adapter in a  
nonvolatile memory device.  
The following is an example of how to save devices in the persistent  
device table using LSI Logic Fcode:  
Step 1. Select the controller you want to modify, making a selection  
from the list as shown in Figure 4.1.  
Figure 4.1 Select Controller  
OpenBoot BIOS  
Copyright © 2002 - 2005 by LSI Logic Corporation. All rights reserved.  
4-15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Step 2. From the displayed list, select a device to mark persistent as  
shown in Figure 4.2.  
Figure 4.2 Select Device  
/pci@1f,0/pci@1/IntraServer,fc@2/disk has been selected.  
ok select /pci@1f,0/pci@1/IntraServer,fc@2  
ok show-children  
MPT Firmware Version 1.02.12  
Target 0  
Unit 0 Disk SEAGATE ST39173FC 6615  
WWN 200000203710c4e8 PortID a3  
Step 3. Type ^Y (Ctrl-Y) to insert disk name in the command line as  
shown in Figure 4.3.  
Figure 4.3 Inserting Disk Name in Command Line  
Note:  
The OpenBoot BIOS (Fcode) provides help when you enter  
a command that does contain the proper arguments. In this  
case, OpenBoot responds with usage syntax.  
Figure 4.4 Setting Device 0 as Persistent  
Note:  
The command sequence in Figure 4.4 records an entry for  
device 0, as item 0 in the persistent device list.  
Figure 4.5 Clearing Persistent Device Map  
Note:  
The command sequence in Figure 4.5 may be used to clear  
an entry in the persistent device map.  
Entry 1 has been deleted from the table, and the table is now empty.  
4-16  
BIOS Features  
Copyright © 2002 - 2005 by LSI Logic Corporation. All rights reserved.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
4.7.8 Manual Selection of FC Topology  
Under certain configurations, you may want to force the selection of FC  
topology and disable the auto detect mechanism in the FC adapter. This  
can be done on a port-by-port basis by using the following procedure.  
Note:  
It should not be necessary to change from automatic  
detection of topology. Also, firmware version 1.00.03 is the  
earliest version to support this functionality.  
The following is an example of how to select a manual topology N_Port  
or NL_Port on a selected FC port.  
Select the controller you want to modify, as follows:  
ok show-disks  
a) /pci@1f,0/pci@1/IntraServer,fc@2/disk  
b) /pci@1f,0/pci@1/IntraServer,Ultra2-scsi@1/disk  
c) /pci@1f,0/pci@1,1/ide@3/cdrom  
d) /pci@1f,0/pci@1,1/ide@3/disk  
e) /pci@1f,0/pci@1,1/ebus@1/fdthree@14,3203f0  
q) NO SELECTION  
Enter Selection, q to quit: a  
/pci@1f,0/pci@1/IntraServer,fc@2/disk has been selected.  
Type ^Y ( Control-Y ) to insert it in the command line.  
e.g. ok nvalias mydev ^Y for creating devalias mydev for  
/pci@1f,0/pci@1/IntraServer,fc@2/disk  
ok select /pci@1f,0/pci@1/IntraServer,fc@2  
Then enter commands as shown in the following example:  
ok show-topology  
Topology selected is auto  
Current topology is unknown (no link)  
ok set-topology <-Command with no options provides help  
usage is <topology> set-topology  
topology = 1 NL_Port  
topology = 2 N_Port  
topology = a auto  
OpenBoot BIOS  
Copyright © 2002 - 2005 by LSI Logic Corporation. All rights reserved.  
4-17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
ok 1 set-topology  
Topology selected is NL_Port  
Topology has been set  
Change will take effect after system power cycle  
ok 2 set-topology  
Topology selected is N_Port  
Topology has been set  
Change will take effect after system power cycle  
ok a set-topology  
Topology selected is auto  
Topology has been set  
Change will take effect after system power cycle  
Note:  
The system must be power-cycled before the changes take  
effect. It is not sufficient to execute the reset-all command.  
4-18  
BIOS Features  
Copyright © 2002 - 2005 by LSI Logic Corporation. All rights reserved.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Customer Feedback  
We would appreciate your feedback on this document. Please copy the  
following page, add your comments, and fax it to us at the number  
shown.  
If appropriate, please also fax copies of any marked-up pages from this  
document.  
Important: Please include your name, phone number, fax number, and  
company address so that we may contact you directly for  
clarification or additional information.  
Thank you for your help in improving the quality of our documents.  
2 Gbit/s Fibre Channel Host Adapters User’s Guide  
Ver. 2.1  
Copyright © 2002 - 2005 by LSI Logic Corporation. All rights reserved.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Reader’s Comments  
Fax your comments to:  
LSI Logic Corporation  
Technical Publications  
M/S E-198  
Fax: 408.433.4333  
Please tell us how you rate this document: 2 Gbit/s Fibre Channel Host  
Adapters User’s Guide. Place a check mark in the appropriate blank for  
each category.  
Excellent Good Average Fair  
Poor  
____  
____  
____  
____  
____  
Completeness of information  
Clarity of information  
____  
____  
____  
____  
____  
____  
____  
____  
____  
____  
____  
____  
____  
____  
____  
____  
____  
____  
____  
____  
Ease of finding information  
Technical content  
Usefulness of examples and  
illustrations  
Overall manual  
____  
____  
____  
____  
____  
What could we do to improve this document?  
If you found errors in this document, please specify the error and page  
number. If appropriate, please fax a marked-up copy of the page(s).  
Please complete the information below so that we may contact you  
directly for clarification or additional information.  
Name  
Date  
Telephone  
Title  
Fax  
Department  
Company Name  
Street  
Mail Stop  
City, State, Zip  
Download from Www.Somanuals.com. All Manuals Search And Download.  

La Crosse Technology Clock 616 146 User Manual
Lanzar Car Audio Car Stereo System OPTS1502 User Manual
Lasko Blower U12100 User Manual
LifeSource Blood Pressure Monitor UB 511 User Manual
Link electronic Network Router 860 XL165AV User Manual
Loewe Flat Panel Television HD+ 100 DR+ User Manual
Mamp;S Systems Stereo System MC111M DM User Manual
Maytag Appliance Trim Kit MEW6530DDB19 User Manual
McCulloch Automobile Parts ZM3816 BF 966582001 User Manual
Mercedes Benz Automobile 2004 CLK Class Coupes User Manual