INSTALLATION INSTRUCTIONS
READ ALL INSTRUCTIONS BEFORE INSTALLATION
INSTALLATION SAFETY INSTRUCTIONS (continued)
BEFORE YOU BEGIN
Remove all tape and packing materials before using the range. Dispose of all plastic bags after
unpacking the range. Never allow children to play with packing materials.
IMPORTANT SAFETY INSTRUCTIONS
Read these instructions completely and carefully. Improper installation, adjustment, alteration, service
or maintenance can cause injury or property damage. Refer to this manual. For assistance or
additional information, consult a qualified installer, service agency, manufacturer (dealer) or the gas
supplier.
This is the safety alert symbol. This symbol alerts you to potential hazards that can kill or
hurt you and others. All safety messages will follow the safety alert symbol and either the
word “WARNING” or “CAUTION”.
This symbol will alert you to hazards or unsafe practices which could
cause serious bodily harm or death.
WARNING
This symbol will alert you to hazards or unsafe practices which could
cause bodily injury or property damage.
CAUTION
WHAT TO DO IF YOU SMELL GAS
WARNING:
If the information in
• DO NOT try to light any appliance.
• DO NOT touch any electrical switch.
• DO NOT use any phone in your building.
this manual is not followed exactly, a fire or
explosion may result causing property damage,
personal injury or death.
• Immediately call your gas supplier from a
neighbor’s phone. Follow the gas supplier’s
instructions.
– DO NOT store or use combustible materials,
gasoline or other flammable vapors and liquids in
the vicinity of this or any other appliance.
• If you cannot reach your gas supplier, call the
fire department.
Installation and service must be performed by
a qualified installer, service agency or the gas
supplier.
3
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION INSTRUCTIONS
READ ALL INSTRUCTIONS BEFORE INSTALLATION
INSTALLATION SAFETY INSTRUCTIONS (continued)
- If the range is pulled away from the wall for
cleaning, service, or any other reason, ensure that
the Anti-Tip Device is properly reengaged when
the range is pushed back against the wall.
WARNING!
• ALL RANGES CAN TIP
• INJURY TO PERSONS
All ranges can tip and injury could result. To prevent
COULD RESULT
accidental tipping of the range, attach an approved
Anti-Tip device to the wall. (See “INSTALLING THE
• INSTALL ANTI-TIP DEVICES
PACKED WITH RANGE
• SEE INSTALLATION
INSTRUCTIONS
ANTI-TIP DEVICE” in this manual.) To check if the
device is installed and engaged properly, carefully
tip the range forward. The Anti-Tip device should
engage and prevent the range from tipping over.
If you pull the range out from the wall for any
reason, make sure the Anti-Tip device is engaged
when you push the range back against the wall.
• DO NOT step or sit on the door. Install the
Anti-Tip Bracket packed with range.
- The range could be tipped and injury might result
from spilled hot liquid, food, or the range itself.
WARNING!
• NEVER reuse old flexible connectors. The use of
old flexible connectors can cause gas leaks and
personal injury. Always use NEW flexible
• Avoid placing cabinets above the range. To
minimize the hazard caused by reaching over the
open flames of operating burners, install a
ventilation hood over the range that projects
forward at least 5” beyond the front of the
cabinets.
connectors when installing a gas appliance.
• Your range must be installed by a qualified
installer.
• The ventilation hood must be constructed of sheet
metal not less than 0.0122” thick. Install above
the cooktop with a clearance of not less than 1/4”
between the hood and the underside of the
combustible material or metal cabinet.
The hood must be at least as wide as the
appliance and centered over the appliance.
Clearance between the cooking surface and
the ventilation hood surface MUST NEVER BE
LESS THAN 24 INCHES.
• Your range should be electrically grounded in
accordance with local codes or, in the absence of
local codes, in accordance with the National
Electrical Code (ANSI/NFPA 70, latest edition). In
Canada, electrical grounding must comply with the
current CSA C22.1 Canadian Electrical Code Part
1 and/or local codes. See “ELECTRICAL
CONNECTIONS” in this manual.
• Before installing your range on linoleum or any
other synthetic floor covering, make sure the floor
covering can resist 180°F(82°C) without shrinking,
warping or discoloring. Do not install the range
over carpeting unless a sheet of 1/4” thick
plywood or similar insulator is placed between the
range and carpeting.
EXCEPTION: Installation of a listed microwave
oven or cooking appliance over the cooktop shall
conform to the installation instructions packed with
that appliance.
• If cabinets are placed above the range, allow a
minimum clearance of 30” between the cooking
surface and the bottom of unprotected cabinets.
• Make sure the wall coverings around the range
can resist heat generated by the range up to
200°F(93°C).
• Leak testing of the appliance shall be conducted
according to the manufacturer’s instructions.
4
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION INSTRUCTIONS
READ ALL INSTRUCTIONS BEFORE INSTALLATION
INSTALLATION SAFETY INSTRUCTIONS (continued)
WARNING!
• If a 30” clearance between cooking surface and
overhead combustible material or metal cabinets
cannot be maintained, protect the underside of the
cabinets above the cooktop with not less than 1/4”
insulating millboard covered with sheet metal not
less than 0.0122” thick. Clearance between the
cooking surface and protected cabinets MUST
NEVER BE LESS THAN 24 INCHES.
• The vertical distance from the plane of the cooking
surface to the bottom of adjacent overhead
cabinets extending closer than 1” to the plane of
the range sides must not be less than 18”. (See
the Dimensions and Clearances illustration in this
manual.)
CAUTION
• Items of interest to children should not be stored in
cabinets above a range or on the backsplash of a
range—children climbing on the range to reach
items could be seriously injured.
• DO NOT attempt to operate the oven of this range
during a power failure.
IN THE COMMONWEALTH OF MASSACHUSETTS
• This product must be installed by a licensed
plumber or gas fitter.
• When using a flexible gas connector, it must not
exceed 3 feet in length.
• When using ball type gas shut-off valves, they shall
be the T-handle type.
PREPARING FOR INSTALLATION
TOOLS YOU WILL NEED
MATERIALS YOU MAY NEED
• Gas line shut-off valve
• Pipe joint sealant that resists action of natural and
LP gases.
Phillips screwdriver
• Flexible metal appliance connector (3/4” or 1/2” NPT
x 1/2” I.D.)
Never use an old connector when installing a new
range.
Open-end or
adjustable wrench
Flat-blade screwdriver
• Flare union adapter for connection to gas supply line
(3/4” or 1/2” NPT x 1/2” I.D.)
Pencil and ruler
Pipe wrench(2)
(one for support)
• Flare union adapter for connection to pressure
regulator on range (1/2” NPT x 1/2” I.D.)
• Liquid leak detector or soapy water.
• Lag bolt or 1/2” O.D. sleeve anchor (for concrete
floors only).
Level
5
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION INSTRUCTIONS
DIMENSIONS AND CLEARANCES
Provide proper clearances between the range and
adjacent combustible surfaces. These dimensions
must be met for safe use of your range. The location
of the electrical outlet and pipe opening (see “GAS
PIPE AND ELECTRICAL OUTLET LOCATIONS”)
may be adjusted to meet specific requirements.
The range may be placed with 0” clearance (flush) at
the back wall.
INSTALLATION
CLEARANCES
Maximum depth
for cabinets
above
Minimum to
cabinets on
either side of
the range
30”
30”
coutertops
13”
Minimum
5”
5”
Minimum
clearance
to left wall
Minimum clearance to
right wall
18”
Front edge of
the range side
panel forward
from cabinet
36”
0”
1/4”
To cabinets
below cooktop
and at the range
back
DIMENSIONS
Depth with door closed (includes door handle)
3
/
28 4”
30”
36” 1/4”
Height
7
/
47 16”
Depth with door open.
5
/
43 32”
6
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION INSTRUCTIONS
LOCATION
Do not locate your range where it may be subject
to strong drafts. Any openings in the floor or wall
behind the range should be sealed. Make sure the
openings around the base of the range that
supply fresh air for combustion and ventilation
are not blocked by carpeting or woodwork.
When the floor covering ends at the front of the
range, the area that the range will be installed on
should be built up with plywood to the same level or
higher than the floor covering. This will allow the
range to be moved for cleaning and servicing, as well
as proper air flow to the range.
Your range, like many other household units, is heavy
and can be installed on soft floor coverings such as
cushioned vinyl or carpeting. Use care when moving
the range on this type of flooring.
It is recommended that the following simple and
inexpensive instructions be followed to protect your
floor.
Also, make sure the floor covering can resist 180°F
(82°C). See the "INSTALLATION SAFETY
INSTRUCTIONS" (included in this manual).
Make sure the wall coverings around your range can
resist the heat generated (up to 200°F/93°C) by the
range. See the "INSTALLATION SAFETY
INSTRUCTIONS" (included in this manual).
7
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION INSTRUCTIONS
GAS PIPE AND ELECTRICAL OUTLET LOCATIONS
30”
91 16”
/
113 32”
/
2”
Recommended area for 120V
outlet on rear wall and area for
through-the wall connection of
pipe stub and shut-off valve.
819 32”
/
3”
145 16”
/
23 8”
/
Recommended area for
through-the floor connection
of pipe stub and shut-off valve.
1. PROVIDE ADEQUATE GAS SUPPLY
Your range is designed to operate at a pressure of
5” of water column on natural gas or 10” of water
column on LP.
For LP gas, the pressure supplied to the regulator
must be between 10” and 13” of water column.
When checking for correct operation of the regulator,
the inlet pressure must be at least 1” more than the
operating (manifold) pressure as given above.
Make sure you are supplying your range with the type
of gas for which it is configured.
This range is convertible for use on natural or LP gas.
The pressure regulator located at the inlet of the
When using this range on LP gas, conversion must be range must remain in the supply line regardless of
made by a qualified LP installer before attempting to
operate the range.
which type of gas is being used.
A flexible metal appliance connector used to connect
the range to the gas supply line should have an I.D. of
5/8” and a max of 5ft. In Canada, flexible connectors
must be single wall metal connectors less than 6 feet
in length.
For proper operation, the pressure of natural gas
supplied to the regulator must be between 5” and 13”
of water column.
8
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION INSTRUCTIONS
2. CONNECT THE RANGE TO GAS
Shut off the range gas supply valve before
removing the old range and leave it off until the
new hook-up has been completed.
Connect a flexible metal appliance connector to
the adapter on the range. Position range to permit
connection at the shut-off valve.
C
Because hard piping restricts movement of the range,
the use of a CSA International-certified flexible metal
appliance connector should be used unless local
codes require a hard-piped connection.
When all connections have been made, be sure
all range controls are in the off position and turn
on the main gas supply valve. Gas leaks may
occur in your system and result in a dangerous
situation. Gas leaks may not be detected by smell
alone.
Check all gas connection joints and fittings for
leaks with a non-corrosive leak detection fluid,
then wipe off.
D
NEVER reuse an old connector when installing a new
range.
To protect against gas leaks, use a qualified pipe joint
sealant on all external threads.
A Install male 1/2” or 3/4” flare union adapter to the
NPT internal thread of the manual shut-off valve,
taking care to back-up the shut-off valve to keep it
from turning.
Gas suppliers recommend you purchase and
install an UL approved gas detector. Install and
use in accordance with Installation instructions.
WARNING!
DO NOT USE A FLAME TO CHECK FOR GAS
LEAKS.
Install male 1/2” flare union adapter to the 1/2”
B
NPT internal thread at inlet of pressure regulator.
Use a backup wrench on the pressure regulator
fitting to prevent damage.
WARNING!
Isolate the range from the gas supply system by
closing its individual shut-off valve during any
pressure testing of the gas supply system at test
pressures equal to or less than 1/2” psig(3.5kPa).
FLEXIBLE CONNECTOR HOOKUP
Adapter
Gas Flow into Range
Pressure regulator
Flex connector
(6 ft. max.)
Adapter
Installer: Inform the
consumer of the
location of the gas
shut-off valve
Gas shut-off valve
1/2” or 3/4”
Gas pipe
9
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION INSTRUCTIONS
3. ELECTRICAL CONNECTIONS
ELECTRICAL REQUIREMENTS
120 Volt, 60 Hertz, properly grounded dedicated circuit protected by a 15 or 20 Amp circuit breaker, or slow
blow fuse.
GROUNDING
IMPORTANT: FOR PERSONAL SAFETY, THIS APPLIANCE MUST BE PROPERLY GROUNDED.
The power cord of this appliance is equipped with a
3-prong (grounding) plug which mates with a standard
3-prong grounding wall receptacle to minimize the
The customer should have the circuit checked by a
possibility of electric shock hazard from this
qualified electrician to make sure the receptacle is
appliance.
CAUTION:
properly grounded.
The customer should have the wall receptacle and
circuit checked by a qualified electrician to make sure
the receptacle is properly grounded.
DO NOT use an adapter plug because disconnecting
of the power cord places undue strain on the adapter
Where a standard two-prong wall receptacle is
and leads to eventual failure of the adapter ground
encountered, it is the personal responsibility and
terminal.
obligation of the customer to have it replaced with a
The installation of appliances designed for mobile
properly grounded three-prong wall receptacle.
home installation must conform with the Manufactured
DO NOT, UNDER ANY CIRCUMSTANCES, CUT OR
Home Construction and Safety Standard, Title 24
REMOVE THE THIRD (GROUND) PRONG FROM
CFR, Part 3280 (formerly the Federal Standard for
Mobile Home Construction and Safety, Title 24, HUD,
THE POWER CORD.
A word about GFCI’s – GFCI’s are not required or
recommended for gas range receptacles.
Part 280) or, when such standard is not applicable,
the Standard for Manufactured Home Installations,
latest edition (Manufactured Home Sites,
Communities and Set-Ups), ANSI A225.1, latest
edition, or with local codes. In Canada, mobile home
installation must be in accordance with the current
CAN/CSA Z240/MH Mobile Home Installation Code.
Ground Fault Circuit Interrupters (GFCI’s) are devices
that sense leakage of current in a circuit and
automatically switch off power when a threshold
leakage level is detected. These devices must be
manually reset by the consumer. The National
Electrical Code requires the use of GFCI’s in kitchen
receptacles installed to serve countertop surfaces.
Performance of the range will not be affected if
operated on a GFCI-protected circuit but occasional
nuisance can occur.
WARNING!
POWER MUST BE DISCONNECTED BEFORE
SERVICING THE APPLIANCE. FAILURE TO DO
SO CAN RESULT IN DEATH OR ELECTRICAL
SHOCK.
PREFERRED
METHOD
Ensure proper ground
exists before use
4. SEAL THE OPENINGS
Seal any openings in the wall and floor after electrical and gas supplies are completed.
10
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION INSTRUCTIONS
5. ASSEMBLE THE SURFACE BURNERS
CAUTION
DO NOT operate the burners without all parts in
place.
Hole
Electrode
Place the burner caps and heads on the cooktop.
Make sure that the caps and heads are placed in the
correct locations. There is one small, one medium,
one large and one extra large burner head and cap.
Make sure the hole in the burner head is positioned
over the electrode.
Center Burner
(on some models)
(on some models)
Oval (Center) Burner Medium burner
Head/Cap Assembly head and cap
Small burner
head and cap
Medium burner
head and cap
(on some (on some
models) models)
Large burner
head and cap
Front of range
Extra large burner
head and cap
6. CHECK IGNITION OF SURFACE BURNERS
ELECTRIC IGNITION
Select a top burner knob and simultaneously push in
QUALITY OF FLAMES
The combustion quality of burner flames needs to be
and turn to the “LITE” position. You will hear a clicking confirmed visually.
sound indicating proper operation of the spark
module.
A Yellow flames—Call for service
Once the air has been purged from the supply lines,
burner should ignite within 4 seconds.
After burner ignites, rotate knob out of the “LITE”
position. Try each burner in succession until all
burners have been checked.
B Yellow tips on outer cones—
It is normal for LP gas
C Soft blue flames—
It is normal for natural gas
With LP gas, some yellow tipping on outer cones is
normal.
11
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION INSTRUCTIONS
7. ADJUST THE SURFACE BURNER TO THE LOW
FLAME(SIMMER) SETTING.
1) Light all surface burners.
2) Turn the knob on the burner being adjusted to
“LO”.
3) Remove knob.
4) Insert a small, flat bladed screwdriver into the valve
shaft as shown in Fig. 1.
Center adjustment screw
Fig. 1
Adjustment screw next to
the valve shaft
On right front valve for model LDG3019ST there is
a secondary adjustment for the low flame for the
outer burners.
Fig. 2
Insert a small, flat blade screwdriver into the hole
next to the valve stem to adjust the outer flame as
shown in Fig. 2.
Turn the adjustment screw until the flame reaches
the desired size.
6) Test the flame stability.
Test 1: Turn the knob from “HI” to “LO” quickly.
If the flame goes out, increase the flame size and test
again.
5) Replace the knob.
Test 2: With the burner on a “LO” setting, open and
close the oven door quickly. If the flame is
extinguished by the air currents created by the door
movement, increase the flame height and test again.
Note: Hold the valve shaft with one hand while turning
the screw for adjustment with the other.
7) Repeat steps 1-6 for each surface burner.
12
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION INSTRUCTIONS
8. CHECK OPERATION OF BAKE/BROIL BURNERS
To check ignition of the Bake burner, follow the steps
below:
To check ignition of the Broil burner, follow the steps
below:
1) Remove all packing from inside the oven cavity.
2) Press "Bake" (350 will be shown in the display).
3) Press Start.
1) Press "Broil" ("Hi" will be shown in the display).
2) Make sure the door is closed.
3) Press Start.
It may take between 30 and 90 seconds for the burner
to start heating.
It may take between 30 and 90 seconds for the burner
to start heating.
NOTE: Do not try and light either the bake or broil
burners during a power outage. The range has an
electrical ignition system and can not be used
without power.
9. AIR SHUTTER ADJUSTMENT FOR BAKE AND BROIL
BURNERS.
The range comes from the factory with air shutters adjusted for proper air flow for natural gas.
If converted to LP, follow the instructions provided in the conversion kit to properly adjust the air shutters.
LP conversion must be performed by a qualified technician.
13
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION INSTRUCTIONS
10. INSTALLING THE ANTI-TIP DEVICE
INSTALL THE BRACKET USING THE
BRACKET INSTALLATION SHEET
WARNING
• Range must be secured with an approved
Anti-Tip device.
• The range could be tipped by standing, sitting
or leaning on an open door if the range or
Anti-Tip device is not properly installed.
• After installing the Anti-Tip device, verify that
it is in place by carefully attempting to tilt the
range forward.
• This range has been designed to meet all
recognized industry tip standards for all
normal conditions.
The Anti-tip bracket is packaged with an installation
template.
The instructions include necessary information to
complete the installation.
Read and follow range installation instruction sheet.
• The installation of the Anti-Tip device must
meet all local codes for securing the
appliance.
• The use of this device does not preclude
tipping of the range when not properly
installed.
11. LEVELING THE RANGE
Install the oven shelves in the oven and locate the
range where it will be installed.
A
Spirit level
Check if the range is level by placing a spirit level
or a cup, partially filled with water, on one of the
oven shelves. If using a spirit level, take two
readings— with the level placed diagonally first in
one direction –➀ and then the other –➁.
B
Remove the lower door. See the “CARE AND
CLEANING OF THE RANGE” section in the
owner's manual. The front and rear leveling legs
can be adjusted from the bottom.
C
D
Use an open-end or adjustable wrench to adjust
the leveling legs until the range is level.
Lower
range
Leg leveler
Raise
range
14
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION INSTRUCTIONS
WHEN ALL HOOKUPS ARE COMPLETE
Make sure all controls are left in the off position. Make sure the flow of combustion and ventilation air
to the range is unblocked.
CONVERTING TO LP GAS
(OR CONVERTING BACK TO NATURAL GAS FROM LP)
This range leaves the factory set for use with
natural gas. The conversion to LP gas must be
performed by a qualified LP gas installer when
converting to LP gas.
The conversion instructions and LP orifices can be
found attached to the range on the back.
Keep these instructions and the orifices in case you
want to convert back to natural gas.
15
Download from Www.Somanuals.com. All Manuals Search And Download.
Memo
16
Download from Www.Somanuals.com. All Manuals Search And Download.
LG Customer Information Center
1-800-243-0000 USA, Consumer User
1-888-865-3026 USA, Commercial User
Register your product Online!
Printed in Mexico
Download from Www.Somanuals.com. All Manuals Search And Download.
|