INSTALLATION AND
OPERATION INSTRUCTIONS
ME43
43" Wood Burning Fireplaces
P/N 850,027M REV. E 12/2007
MODEL
ME43BK SP
This installation manual will enable you to obtain a safe, efficient and
dependable installation of your fireplace system. Please read and
understand these instructions before beginning your installation.
Donotalterormodifythefireplaceoritscomponentsunderanycircum-
stances. Anymodificationoralterationofthefireplacesystem,including
but not limited to the fireplace, chimney components and accessories,
may void the warranty, listings and approvals of this system and could
result in an unsafe and potentially dangerous installation.
Lennox™ wood-burning fireplaces are designed for use as a supple-
mental heater. They are not intended for continuous use as a primary
heat source.
RETAIN THESE INSTRUCTIONS
FOR FUTURE REFERENCE
WARNINGS
• Thefireplacecannotbeoperatedwithoutadoor.
Consult your dealer to select the correct door
model.
WARNINGS
• Hot! Do not touch! The glass and
surfaces of this appliance will be hot
during operation and will retain heat
for a while after shutting off the appli-
ance. Severe burns may result.
• Carefully supervise children in the
same room as appliance.
• Important! To assure proper alignment of glass
doors: Install this fireplace in a square and
plumb condition, using shims as necessary at
sides and/or bottom.
• Install the fireplace only as described in these
instructions.
Listed to standards:
ULC-S610 & UL-127
Report No. 192-5166
PIME43-F REV. 3
Download from Www.Somanuals.com. All Manuals Search And Download.
• ThisfireplacemustbeinstalledwithSecurity
Chimneys™ASHT+,S-2100+orAC(8"inside
diameter) chimney System only. These sys-
tems are intended for use in any application
where a traditional masonry type fireplace
would apply. The chimney system must
always vent to the outside of the building.
CONGRATULATIONS!
In selecting this LENNOX™ wood-burning appliance you have chosen one of the fin-
est fireplaces available. The ME43 wood fireplace is a clean burning fireplace that is
designed to provide you dependable service as well as warmth and enjoyment for many
years to come.
Please carefully read and follow all of the instructions found in this manual. Please pay
special attention to the safety instructions provided in this manual. This information
will be useful to you now and in years to come, so keep the manual handy and refer to
it as needed.
• This fireplace has been tested for installa-
tion in Canada to CAN/ULC S610-M87 and
ANSI/UL 127-1996 under report number
192-5166. ForinstallationsinCanada, the
chimney clearance to combustibles must
be 2 inches and the Cold Climate Kit must
be installed.
SAFETY RULES FOR OPERATING
YOUR FIREPLACE
TABLE OF CONTENTS
Safety Rules.......................................Page 2
Parts Required...................................Page 3
Optional Equipment............................Page 3
Fireplace Maintenance
CAUTION
• The minimum installed height of the
completed fireplace system is 15' 0". The
maximum height is 60' 0".
This appliance is designed for
use with wood or certified pro-
cessed solid fuel fire logs. Do
not poke or stir the logs while
they are burning. Use only fire
logs that have been evaluated
for the application in fireplace
andrefertofirelogwarningsand
caution markings on packaging
prior to use.
Creosote ............................................Page 4
Chimney maintenance........................Page 4
Chimney fires.....................................Page 4
Door Frame Care................................Page 4
Glass cleaning....................................Page 4
Doors adjustment ..............................Page 4
Glass replacement..............................Page 4
Removal of ashes...............................Page 4
Fireplace Operation
Fuel....................................................Page 5
First fires............................................Page 5
Building a fire.....................................Page 5
Using the retractable
PARTS REqUIRED
Fireplace Model ME43BK SP
• 8"diameterchimney-ModelSecureTemp™
(ASHT1"),SecureTemp(S-2100+)orACmanu-
factured by Security Chimneys International
only, including:
• Use only Lennox Fireplace glass doors,
specifically designed for ME43 fireplace.
(See Page 22 for part numbers).
doors and firescreens ......................Page 5
How to use the outside air kit.............Page 5
Fireplace Installation
- Chimney lengths
Pre-installation...................................Page 5
Tools and building supplies................Page 6
Precautions........................................Page 6
Installation procedure ........................Page 6
Locating the fireplace.........................Page 6
Adjacent walls....................................Page 6
Enclosure...........................................Page 6
Facing and mantel..............................Page 7
Hearth extension................................Page 8
Outside air installation .......................Page 8
UZY3 fan kit installation ....................Page 9
Framing Dimensions..........................Page 10
Central forced air kit...........................Page 11
Chase Enclosure ................................Page 11
Chimney System ...............................Page 12
Installing the Chimney System...........Page 13
Offset Chimney Installation................Page 16
Chimney Component Chart................Page 17
Angled Wall Radiation Shield .............Page 18
Universal Roof Support Installation ...Page 19
Multiple Terminations.........................Page 19
Parts and Components.......................Page 20
Replacement Parts.............................Page 22
Specifications.....................................Page 22
Clearances .........................................Page 22
Product Reference Information..........Page 24
- Elbows (where necessary)
- Associated components as per these
Installation Instructions
• Do not operate the fireplace with both
firescreens and doors closed at the same
time. Use the firescreen when doors are
fully opened.
• Door (included)
• Always keep the fire screen or the doors
closed and the damper opened when using
the fireplace. Keep the damper closed when
the fireplace is not in use.
• Outside Air Kit (included)
OPTIONAL EqUIPMENT
• The ME43 fireplace is sold with a steel log
grate. If you have to replace it, we recom-
mend for optimum efficiency, to replace it
with an identical or similar Lennox model
grate.
Additional Equipment (optional)
- Trim Kit and Door Capping available in
Nickel and Gold
- UZY5 blower
• Afireplaceinsertheatingunitmaybeinstalled
in the fireplace only if this unit has been
certified with the ME43 fireplace.
- VRUW Blower motor speed control
- Forced Air Heating Kit
3
Download from Www.Somanuals.com. All Manuals Search And Download.
6. Watchforsmoulderingorfireoncombustibles
next to the fireplace and chimney. Check outside
toensurethatsparksandhotemberscomingout
of the chimney are not igniting the roof.
The glass doors can be adjusted by loosening
the three (3) screws of the hinges’ supports
(see fastening screws in Figure 1). If a minor
angular adjustment is needed, you may loosen
only two (2) of the three (3) screws using the
other as a pivot point.
FIREPLACE MAINTENANCE
CREOSOTE
When wood is burned slowly, it produces tar
and other organic vapors which combine with
expelledmoisturetoformablackdepositcalled
creosote. The creosote vapors condense in the
relatively cool chimney flue of a slow burning
fire. As a result, creosote residue accumulates
on the flue lining. When ignited, this creosote
makes an extremely hot fire. If the creosote
accumulation is large, a creosote fire in the
chimney can damage the chimney and over-
heat the surrounding wood framing. Creosote
formation in a chimney can be minimized by
makingsmallhotfiresratherthanslowburning,
smouldering fires.
7. Do not use the fireplace again until your
chimney and fireplace have been inspected by
a qualified chimney sweep or a fire department
inspector.
Glass Replacement
The glass used for the ME43 fireplace doors is
a high temperature ceramic glass. If the glass
breaks,itmustbereplacedwithaceramicglass
suchasNeoceram. Temperedorordinaryglass
will not withstand the high temperatures of
the ELITE ME43 fireplace. Replacement glass
shouldbepurchasedfromyourlocalLHPdealer.
Do not operate the unit with cracked or broken
glass. To remove the glass panel, unscrew the
frame screws, remove the interior frame and
the glass panel.
Door Frame Care
Use a glass cleaner and a soft cloth to polish
the frame. Do not use abrasives such as steel
wool or steel pads for they may scratch the
door frame finish.
Glass Cleaning
The ME43 fireplace is designed to keep the
glass clean under normal operating condi-
tions. To clean the glass there are a number of
specially designed cleaners. Your authorized
LHP Dealer can recommend a suitable cleaner.
Regularhouseholdglasscleanerswillnotclean
creosote. Do not use abrasives such as steel
pads, steel wool or oven cleaner as they will
scratch the glass.
CHIMNEY MAINTENANCE
Regular chimney inspection and maintenance
combined with proper operation will help pre-
vent chimney fires. Keep your chimney clean.
Donotallowmorethana1/16"(1.6mm)build-up
of creosote in your chimney. The amount of
creosote will depend on variables such as fre-
quency of use and type of fire. We recommend
that you follow the instructions below:
Removal Of Ashes
Remove ashes only when the fire is out and the
ashes are cold. Lift the front of the log grate
until it rests against the rear refractory; then
remove the ashes. Ashes should be placed in
a metal container with a tight-fitting lid. The
closed container of ashes should be placed on
a non-combustible floor or on the ground, well
away from all combustible materials, pending
final disposal. If the ashes are disposed of by
burialinsoilorotherwiselocallydispersed,they
should be retained in the closed container until
allcindershavethoroughlycooled. Donotleave
the ashes in the house as they give off carbon
monoxide and other toxic gases.
Doors Adjustment
1. Initially, inspect the chimney system weekly.
By doing this, you will learn how often it will be
necessary to clean your chimney.
Glass doors may lose their adjustment during
transportation or installation of the fireplace.
A wrong adjustment may cause a loss in
combustion’s efficiency and control. The glass
doors must be parallel, at the same height and
must almost touch each other when closed.
Maximum spacing between the doors is one
sixteenth of an inch (1/16’’).
2. Have your chimney cleaned by a qualified
chimney sweep. Chimney maintenance should
only be conducted by a qualified technical or
chimney sweep company.
3. Donotexpectchemicalcleanerstokeepyour
chimney clean.
The raincap can be removed for inspection
and/or cleaning of the chimney. Unscrew the
braceswhichattachtheraincaptothechimney.
Using gloves, firmly grip the upper portion of
the rain cap. Turn the cap and lift it off the
chimney.
Fastening
Screws
CHIMNEY FIRES
If you are having a chimney fire, follow these
steps:
1. Close the glass doors and the air inlet.
2. Close the chimney outside air register.
3. Alert your family of the possible danger.
Frame
Screws
4. If you require assistance, alert your fire
department.
5. If possible, use a dry chemical fire extin-
guisher, baking soda or sand to control the fire.
Do not use water as it may cause dangerous
steam explosions.
Interior Frame
Figure 1
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
4
Download from Www.Somanuals.com. All Manuals Search And Download.
HOW TO USE THE RETRACTABLE DOORS
AND FIRESCREENS
HOWTOUSETHEOUTSIDEAIRREGISTER
(FIREPLACE)
OPERATING THE FIREPLACE
Fuel
The outside air register is located on the upper
part of the top louver. The outside air register
supplies oxygen to the fire and allows control
of the fire when the doors are closed. The fresh
air must come from outside the house (the
air intake must not draw air from inside the
house). This will minimize negative pressure
in the house. The more you slide the register
to the left, the more fresh air into the firebox
and the more accelerated combustion you will
get (see Figure 3). When starting a fire, the
register should always be fully opened.
TheLennoxME43fireplacefeaturesretractable
doors and firescreens in order to allow a wider
view of the fire and save space when the doors
are opened. To retract the doors, simply open
them at 90° and push them into the opening
on the side of the firebox. The same procedure
applies for the retractable firescreens. (see
Figure 2).
The ME43 fireplace is designed to work best
when fueled with seasoned cordwood. Hard-
woods are preferred to softwoods since the
energycontentofwoodisrelativetoitsdensity.
Hardwoods will result in a longer burning fire
and less frequent refueling. A moisture con-
tent of 15% to 20% (seasoned) is preferred.
Excessively wet wood will be difficult to burn
and will result in lower efficiency and increased
creosoting.
Note : Donotoperatethefireplacewithbothfire-
screen and doors closed at the same time.
Do not burn scrap or garbage, treated wood or
wood such as driftwood from the ocean which
has been exposed to salt or other chemicals.
Salt or chemicals can corrode the firebox and
chimney. Do not abuse the unit by burning
large amounts of paper, cardboard, Christmas
tree branches or building construction materi-
als such as pressed wood, plywood or lumber.
Intense firing with these may overheat the
fireplace, causing damage to the unit, a fire,
or even possibly igniting a chimney fire, if the
chimney is creosoted.
FIREPLACE INSTALLATION
Preinstallation
Please Read Before Installing:
1. Before beginning the installation of your
fireplace, read these safety tips and instal-
lation instructions carefully to be sure you
understand them completely. Failure to
followthemcouldcauseafireplacemalfunc-
tion resulting in serious bodily injury and/or
property damage.
First Fires
2. TheME43fireplacehasbeentestedandlisted
toULandULCstandardsbyWarnockHersey
International Inc. These instructions were
written to give you an outline for a fast and
safe installation and trouble-free operation.
The first 5 or 6 fires should be small fires of
shortduration(about30-60minutes). Thefirst
fire should be especially short. This will help
cure the refractory bricks. The first fires may
produce slight smoking and some odor due
to drying of the paint and steel and any dust
accumulated on the fireplace will be burn off at
this time. For this reason the room should be
well ventilated during the first few fires.
Figure 2
PUSH TO
OPEN
Building A Fire
PUSH TO OPEN
Tostartafire,placeseveralcrumpledupballsof
newspaperinthefirebox. Placesmalldrypieces
ofkindlingontopofthepaper,crisscrossingthe
kindling so that there is airspaces in between.
Place the larger pieces of kindling on top of the
pile. Keep the fuel far back enough so that air
can get underneath. Open the air control fully
and light the newspaper. Once the kindling fire
is well established, cordwood can be added.
The unit will burn best with a minimum of two
piecesofcordwoodspaced1"to2"apartandal-
lowingairtogetunderthefuel. Crisscrossingor
arrangingthefuelsothataircangetunderneath,
will help the fire to get started easily.
Figure 3
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
5
Download from Www.Somanuals.com. All Manuals Search And Download.
FailuretouseLHPpartsorconductvariations
in techniques and construction materials
described in this installation manual may
create a serious fire hazard and may void
the warranty and the WHI listing.
Tools And Building Supplies Normally
Required
LOCATING THE LENNOX FIREPLACE
Do not place the fireplace on carpeting, vinyl
or other soft surface floor coverings. It may,
however, be directly placed on flat wood,
plywood, particle board or other hard surface
materials.
Tools:
Phillips screwdriver
Slot style screwdriver
Hammer
Saw and/or Sabersaw
Level
Measuring tape
Plumb line
Electric drill and bits
Pliers
3. Always check your local building codes.
The installation must comply with their
regulations. Before beginning the instal-
lation, consult the local authorities and
make sure your building permit complies
with their requirements.
ADjACENT WALL
A wall perpendicular to and in front of the fire-
place front facing must be at least 18" (460mm)
from the fireplace opening. A wall at 45º to the
front facing and starting at the fireplace’s outer
edge is permitted. Projections within this area
are permitted. See Figure 4.
4. ThisfireplacemustbeinstalledwithSecurity
Square
Chimneys™chimneysystemmodelsASHT+,
S-2100+ or AC, of 8" inside diameter. These
systems are intended for use in any applica-
tionwhereatraditionalmasonrytypefireplace
would apply. The chimney system must
always vent to the outside of the building.
If gas pipe is used:
Pipe wrench
Pipe cutter
Pipe threader
Pipe joint compound
Pipe key valve
STANDOFFS
WALL
5. To maintain top efficiency and to prevent
build-up of soot and creosote, inspect and
clean the chimney periodically during the
heating season.
FIREPLACE
Building supplies:
2" x 3" or heavier lumber
Drywall panel or equivalent
OPENING
Silicone caulking (non-combustible)
Overlay material for fireplace façade
Hearth extension (non-combustible)
6. To prevent possible hazards due to poor
combustion and to avoid affecting other fuel
burning appliances (furnace, wood stove,
etc.),ensurethattheoutsideairkitisproperly
installed.
45°
18"
(460mm)
PRECAUTIONS!
Figure 4
The most important areas of concern dealing
with the fireplace installation are clearances
to combustible materials, secure assembly of
components parts, the height of the chimney
system, the proper use of accessory equip-
ment and the techniques used in using finish-
ing materials applied to fireplace surrounds,
hearth extensions and wall coverings. Each
of these topics will be covered in greater detail
throughout this manual. Please give special
attentiontotheseinstructionsasyouprogress
with your installation.
7. This fireplace is designed to allow the instal-
lation of a gas burner. In such a case, the
installation must conform with the National
Gas Code ANSI Z223.1 and Z21.60.
ENCLOSURE
WARNING
WARNING
When using a gas burner, it is
mandatory to keep the chimney
outside air register opened.
Do not place loose insulation or
any other material in the space
around the fireplace or the
chimney. Insulation placed on
or around the fireplace or chim-
neymaycauseadjacentwoodto
overheat and catch on fire.
8. This fireplace has provision for the installa-
tion of a gas pipe and is intended only for
connection to a decorative gas appliance
incorporating an automatic shutoff device
and complying with ANSI Z21.60-M96/CGA
2.26-M96, Standard for Decorative Gas Ap-
pliancesforInstallationinSolid-FuelBurning
Fireplaces (reference Clause 4.1.3 T).
Fireplace Installation Procedure
1. Move the fireplace into the desired position
(follow the recommendations below for
enclosure).
2. Install the outside air assembly (or assem-
blies) - refer to Page 8.
3. Install the enclosure surrounding the fire-
place(refertothesections“Enclosure”below
and “ Facing and Mantel” on Page 7).
4. Install the hearth extension (see Page 8).
Make sure the gap between the fireplace
and the hearth extension is sealed.
1. The fireplace must be installed against a
finished wall (like drywall finish). It must
not be installed against a vapor barrier or
exposed insulation (see Figure 5).
9. The ME43 fireplaces are sold with factory
installed doors. The outside combustion
air kit is mandatory and is included with the
fireplace. Optional blowers and decorative
trims are available.
2. Combustible materials like wood, plywood,
particle board or drywall can be in direct
contact with the fireplace standoffs. Two
inch (50mm) clearance to combustibles
must be kept around the chimney.
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
6
Download from Www.Somanuals.com. All Manuals Search And Download.
Fireplace Facing
WARNING
DRYWALL PANEL OR EQUIVALENT
2" x 3" MIN.
The fireplace should be framed using 2" x 3"
(50mm x 75mm) or heavier lumber.
The top of the fireplace is not
zero clearance. Do not place
any insulating material in the
space above the fireplace for a
height of 7 feet from the base of
the fireplace.
Figure 10 on Page 10 shows the general
framing layout.
SPACER
Combustible materials must be installed
flush with the fireplace facing. They may not
project out in front of the fireplace. Non-
combustible materials such as brick, stone or
ceramic tile, may project in front of and/or on
the fireplace facing.
FIREPLACE
3. Do not block the fireplace’s hot air vents or
air inlets as this will cause the fireplace to
overheat.
Figure 6
WARNING
FLASHING
The header should rest on top
of the metal spacers. Do not
alter the spacers or notch the
header to fit around them. Do
not block the air inlet or outlet
as this will cause the fireplace
to overheat.
ROOF SUPPORT
NON COMBUSTIBLE
CHASE TOP
ATTIC
FIRESTOP
CEILING/FLOOR
SEPARATION
Mantel
A wood mantel, if installed, must be at least
48" (1.2 m) above the base of the fireplace (see
Figure 7). There is no restriction regarding the
length or the width of the mantel.
MUST HAVE THE SAME FIRE RATING
AS ADJACENT CEILING.
2"
MUST HAVE THE SAME INSULATION
AS ADJACENT CEILING.
LOCAL CODE REGULATION FOR CEILING
MUST BE APPLIED TO THE CEILING/FLOOR
SEPARATION, I.E. FIRESTOP, ETC.
7 ft. Min.
FINISHED
WALL
48"
Min.
8"
1"
52"
18"
NOTE: Chase wall and floor must be insulated
in the same manner than the rest of the building
below the attic.
Figure 7
Figure 5
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
7
Download from Www.Somanuals.com. All Manuals Search And Download.
4. The outside air assembly must draw air from
outside the house. It must not draw air from
the attic, the basement or a garage.
5. Locate the outside register where it will be
well away from automobile exhaust fumes
or other vents.
6. The outside air register should be installed
where it is not likely to be blocked by snow
or exposed to extreme wind.
7. It is recommended to install the outside air
register at floor level. However, if you must
raisetheairregisterabovethefireplacelevel,
you will have to make a loop to the floor with
the flexible pipe to prevent from causing a
draft in the outside air register (see Figure
8 Detail A).
Hearth Extension Requirements
Outside Air Installation
(refer to Figure 7)
The outside air assembly must be installed
according to the following guidelines:
A non-combustible hearth extension must
be built in front of the fireplace and extend
out on both sides. Hearth extensions must
be constructed according to the following
guidelines:
1. The maximum length of 4" I.D. (100 mm)
insulated flexible duct is 20 feet (6.1 m). If a
longerductisrequired,usea6"I.D.(150mm)
insulatedflexibleduct. Themaximumlength
is 40 feet (12 m). Refer to Figures 8B and
8C for connections.
2. The duct and register may be installed above
or below floor level.
3. The outside air register must not be installed
more than 7 feet (2.1 m) above the base of
the fireplace.
1. Alayerofsheetmetal0.018"(0.45mm)thick
or 3/8" (9mm) thick insulating board or any
other material (tiles, marble, granite) with
equivalent heat resistance may be used.
Check with the local building authorities
before installing to determine what other
materials are acceptable in your area.
2. The hearth extension should be secured to
the floor. The gap between the fireplace and
the hearth extension must be sealed with
non-combustible caulking or cement.
3. Onaraisedbaseorraisedhearth,a“Z”shape
piece of metal must be fabricated to join the
bottom of the fireplace to the floor.
Outside Air Assembly
The outside air assembly is mandatory for
the fireplace.
7' MAX.
During operation, the fireplace requires air for
combustion and draws air out of the house. It
may starve other fuel burning appliances such
as gas or oil furnaces. As well, exhaust fans
and fan driven appliances may compete for
air, causing a negative pressure in the home,
resulting in smoke entering the home from
the fireplace. This situation is aggravated in
modern airtight houses.
LOOP IS MANDATORY
To overcome this potential problem, the
installation of an outside air assembly is
required to provide outside combustion air to
the fireplace.
(Detail A)
OUTSIDE AIR CONNECTION
ALUMINIUM TAPE
OUTSIDE AIR CONNECTION
TO THE FIREPLACE
FIREPLACE
CONNECTION
OUTSIDE
INTAKE
PLASTIC
COVER
ALUMINIUM
TAPE
SCREW
OPENING
FACING DOWN
INSULATION
WALL
FLEXIBLE PIPE
FLEXIBLE
PIPE
FIREPLACE
PLASTIC COVER
(Detail B)
(Detail C)
Figure 8
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
8
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION OF THE FAN KIT MODEL
UZY3
NOTE: The fireplace must be electrically connected and grounded in accordance with local codes
or in the absence of local codes, with the current CSA C22.1 Canadian Electrical Code. For U.S.A.
installations, follow local codes and the National Electrical Code ANSI/NFPA No 70.
Note: This fan kit can easily be installed when
the fireplace has a pre-installed junction box.
You just have to plug them in.
CAUTION: SHOULD THIS FAN REqUIRE SERVICING, THE POWER SUPPLY MUST BE DISCON-
NECTED.
These fans require periodic maintenance. Check the area in front of the fans and wipe or vacuum
at least once a month during the burn season.
Rating: 120 Volts, 60Hz, .63A.
The fans have magnetic blower mounts. The
junction box (factory installed on approved
fireplaces for the use of this fan kit) must be
connected to 110 VAC service before perma-
nently enclosing the fireplace. The access hole
for connecting the 110 VAC is located on the
lower right exterior side of the fireplace.
THERMODISC, AUTOMATIC
THERMAL FAN ACTIVATOR
FAN WITH
MAGNET
FAN WITH
MAGNET
Installation instructions:
1. Open the bottom louver of the fireplace.
2. Place each fan kit into the fireplace side
opening 1" from the back of the fire-
place.
CONNECTOR FOR
OPTIONAL RHEOSTAT
ELECTRICAL CONNECTION
WITH
GROUND CONNECTION
Figure 9
3. Install the automatic fan activator on the
side of the firebox (the fan activator has
a magnetic mount).
4. Plug the fan kit into the junction box.
5. Ground both fans to the back panel using
the green screws (see Figure 9).
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
9
Download from Www.Somanuals.com. All Manuals Search And Download.
Corner Installation
23-11/32”
(593mm)
Notes
j
Due to Lennox' ongoing commitment
to quality, all specifications, ratings
and dimensions are subject to change
without notice.
D
2" X 3"
MIN.
F
All framing dimensions calculated for
1/2" dry wall at the fireplace face. If
sheathing the chase or finishing with
other thickness materials, calculations
will need to be made.
*Thefireplacemustnotbeincontactwith
any insulation or loose filling material.
CovertheinsulationwithDrywallpanels
around the fireplace.
21-1/2”
(546mm)
E
Combustible materials can NOT be
used in the space directly above the
fireplace. Do not fill the space above
the fireplace with any material (Except
the wood framing)
G
7' MIN.
Back Wall of Chase/Enclosure
Including Finising Materials if any
OUTSIDE CHASE
B
A
C
L
*
FRAMING DIMENSIONS
Fireplace Opening Width
G
H
Rough Framing Face
(unfinished shown)
A
B
C
D
E
F
G
H
j
42-1/2"
43-1/4"
33"
1080 mm
1099 mm
838 mm
419 mm
2159 mm
1080 mm
686 mm
660 mm
1527 mm
203 mm
25 mm
Rough Framing Face (Unfinished Shown)
* Zero Clearance From Back Spacer to Wall
16-1/2"
85"
42-1/2"
27"
Combustion
Air Kit
33”
(838mm)
26"
60-1/8"
8"
10-5/8”
(270 mm)
K
L
1"
27-1/2”
(699 mm)
K
43”
(1092 mm)
42-1/2”
(1080 mm)
Knock-Out
for Ducting
Knock-Out
for Ducting
42”
(1067 mm)
43”
(1092 mm)
17-1/8”
(435 mm)
21-1/4
(540 mm)
Outside Air
Intake
28-5/16”
(719 mm)
36”
(914 mm)
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Figure 10 - Framing Dimensions
10
Download from Www.Somanuals.com. All Manuals Search And Download.
CENTRAL FORCED AIR KIT
The knock-outs provided on the sides of the
ME43fireplaceallowtheconnectionofinsulated
flexiblepipewhichenablesyoutoheatadjacent
rooms up to 50 feet from the fireplace.
The ducting system must be installed as de-
scribed below :
INSULATED
FLEX PIPE
1. Fixtheadaptoratthesideofthefireplaceby
twist-locking the adaptor to the fireplace.
You can use more than one outlet on the
fireplace (Figure 11).
2. Attach the 5" flexible pipe, using the col-
lars provided. Important: Make sure that
the plastic wrapping around the flexible
pipe will not be in contact with the fire-
place.
3. Route the flexible pipe to the chosen loca-
tion. The ducting system can be installed
either in an upper room or in a lower
room.
Figure 11
4. Attach the flexible pipe to the fan, using
the collars (Figure 12).
5. Fix the decorative grill fan adaptor to the
fan.
INSULATION
FAN
FLEX 5” O
6. Attach a standard 3" x 10" grill to the
adaptor.
7. Install the blower thermostat in that part
of the house to be heated by the hot air
duct. Do not install the blower thermostat
in the room where the fireplace is located.
Acoolingthermostatcanbeinstalledinthe
same room as the unit. This thermostat
will turn on the blower when the room
where the fireplace is located becomes
too hot.
ALUMINUM TAPE
COLLAR
Figure 12
Thisoptionrequireselectricity. Makesurethat
the connections to the fan have been made
according to the local codes and comply with
their requirements. It is possible to connect
a flexible pipe to a central heating system.
Make sure the pipe will be connected to the
warm air supply duct, not to the return air
duct (Figure 13). Contact your local furnace
installer for installation guidelines.
FAN
5” O
INSULATED FLEX
NO-RETURN
VALVE
Chase Enclosure
AIR FLOW
Achaseisaverticalbox-likestructureconstruct-
edtosurroundthefireplaceandchimney. Refer
to Figure 14 for a typical chase configuration.
Aswithallchimneyinstallations,avoidoverhead
obstructions such as trees, power lines, etc.
A chase should be constructed and insulated
just like any outside wall. In a cold climate, we
recommend the base of the chase should also
beinsulatedbetweenthesolidcontinuousfloor
beneath the fireplace and the chase bottom.
Chase insulation in a cold climate installation
is not required for safety.
FURNACE
Figure 13
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
11
Download from Www.Somanuals.com. All Manuals Search And Download.
AC chimney should not be used in cold areas,
where temperatures are likely to fall below 32°
F (0° C), or altitudes above 4000 feet.
Insulate joists
WARNING
Same As Ceiling
Ifinsulationisused,thefireplace
must not be placed directly
against it. Insulation or vapor
barriers, if used, must first be
covered with drywall panels,
plywood, particle board or other
materialtoassureinsulationand
vapor barriers remain in place.
A chimney venting a fireplace shall not vent any
other appliance.
The minimum system heights are indicated
in Table 1.
Draft Stops
Firestop
Inaltitude, add18"(450mm)tothechimneyfor
every 2000 feet (600 m) above sea level.
CTDT
All chimney installations must include at least
one support. The maximum length of chimney
that can be supported by the fireplace is 12 feet
(3.6 m) for S-2100+, 18 feet (5.4 m) for ASHT+
and 26 feet (8 m) for AC chimney.
Termination
WARNING
Note: Non-
Combustible
Chase
Do not pack or fill required air
spaces with insulation or other
material.Nomaterialisallowed
in these areas.
Flashing
Must Be
Used To
Cover
The chimney must extend at least 3 feet
(915mm) above its point of contact with the
roof and at least 2 feet (610mm) higher than
any wall, roof or building within 10 feet (3 m)
of it (see Figure 15).
Chase
Opening
*Construction Materials:
• framing materials • paneling
• particle board
• dry wall
• plywood
• flooring
• etc.
Optional
Insulation
In Outside
Walls Of
Chase
If the chimney extends higher than 5 feet
(1500mm) above its point of contact with the
roof, it must be secured using a roof brace
or guide wires.
8'
Note: 2" clearance to combustibles around
chimney components required.
Level
A rain cap must be installed on top of the chim-
ney. Failure to install a rain cap may cause the
fireplace to corrode and operate inefficiently.
Solid
Continuous
Surface
Note: Do not insulate the chase cavity with
blown or fill type insulation materials.
Cut and frame square holes in all floors and
the roof to provide a 2" (50mm) clearance
between the chimney and any combustible
materials. Do not fill this 2" (50mm) space
with any material.
Outside
Base
Insulation
(Thermal Barrier)
Note: Local codes may not require firestopping
at the ceiling levels for outside chase installa-
tions. However, it is recommended for safety
and the reduction of heat loss.
Figure 14
Portions of the chimney which may extend
through accessible spaces must be enclosed
to avoid contact with combustible materials or
Chimney Height
CHIMNEY SYSTEM
The total height of your completed fireplace
systemfromthesurfacethefireplacerestsonto
the chimney top must not exceed 60' and must
alsomeetminimumheightrequirements.Refer
to the minimum system height chart.
damage the chimney.
The ME43 fireplace is listed only with Security
Chimneys™ International Ltd. chimney sys-
tems, models ASHT+ 8", S-2100+ 8", or AC
8". Do not connect the fireplace to a masonry
chimney, chimney liner, or other brand of
factory-built chimney.
Minimum System Heights
Fireplace Model
Chimney Model
ME43BK SP
ASHT+ / S-2100+ / AC
15 feet (4.57 m)
18 feet (5.49 m)
Vertical Installation
One Offset (2 elbows)
In areas with continuous temperatures below
0º F (-18º C), the use of an exterior chimney
increases the likelihood of operating problems
such as low draft, high rate of creosoting and
poor start up characteristics. Exterior chim-
neys are also prone to down-drafting and flow
reversal. Installations located in a basement,
in combination with outside chimneys, are
especially prone to flow reversal. In cold areas,
air cooled chimneys should not be used in an
exterior installation.
2' min.
(610mm)
3' min.
(915mm)
Two Offsets (4 elbows) 20 feet (6.10 m)
10' (3000mm)
Table 1
Figure 15
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
12
Download from Www.Somanuals.com. All Manuals Search And Download.
From below, install a firestop in each ceiling/
floorseparationthroughwhichthechimneywill
pass. At the attic level, install an attic radiation
shield from above (see Figures 17A & 17B).
CHIMNEY INSTALLATION
INSTRUCTIONS
ATTIC
RADIANT
FIRESTOP
STRAIGHT INSTALLATION
For ASHT+ and S-2100+ chimneys, place the
first chimney length on the fireplace. To lock
it into place, turn 1/4 of a turn clockwise. With
theACchimneyyoumustuseastartingsection
before installing the first chimney length (see
Figure18). Continueinstallingchimneylengths
until you reach the desired height.
Cutandframetheholesintheceiling, floorand
roof where the chimney will pass (see Figure
16). Use a plumb-bob to line up the center of
the holes. The hole sizes are indicated in Table
2 for the floor and ceiling holes and in Table 3
on Page 15 for the roof holes.
ASHT+ & S-2100+
FIRESTOP
Every time the chimney passes through a
roof or a wall, install the appropriate firestop.
When you reach the desired height, install the
roof support (see instructions included with
the support).
Figure 17A
Then, put the roof flashing in place and seal
the joint between the roof and the flashing
with roofing pitch. For sloping roofs, place the
flashingundertheuppershinglesandontopof
the lower shingles. Nail the flashing to the roof,
using roofing nails (Figures 19A & 19B).
AC RSA
Figure 16
AC RS
Place the storm collar over the flashing and
tightenitwiththeboltsupplied. Finally,sealthe
jointbetweenthestormcollarandthechimney,
using silicone caulking.
CHIMNEY MODEL
SqUARE HOLE
SIZE OPENING
AC
ASHT+
S-2100+ / HT6000+
AC
14-3/8” (365 mm)
16” (406 mm)
15" (380 mm)
Figure 17B
Install the chimney cap. Once the chimney cap
is in place, the roof flashing can be washed
with a solvent or vinegar and then painted with
rust-proof paint.
Note: See Table 3 for Sloped Roof Framing
Table 2 - Flat Roof Framing
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
13
Download from Www.Somanuals.com. All Manuals Search And Download.
AC Model
(Air Cooled Insulated, Galvalume Chimney)
Rain Cap
Flashing Collar
Flashing
Support
Attic Radiation
Shield
Radiation
Shield
AC Air Cooled
Chimney Start-
ing Piece
Cooling Air Kit
For Air Cooled
Chimney ACZI
Outside Combustion
Air Kit (UZI)
Note: The Outside
Air Kit is Mandatory
Figure 18
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
14
Download from Www.Somanuals.com. All Manuals Search And Download.
CHIMNEY
COLLAR
SPACER
(BUILT INTO
FLASHING)
FLASHING
AC CHIMNEY
Figure 19A
Figure 19B
ROOF DOWN SLOPE HOLE SIZE
SLOPE
ASHT+
S-2100+
AC
8"
8"
8"
*
14-3/8" (365mm)
14-5/8" (371mm)
15-1/4" (387mm)
16-1/8" (410mm)
17-3/8" (441mm)
18-3/4" (476mm)
20-3/8" (518mm)
16" (406mm)
15" (380mm)
15-3/8" (390mm)
16-1/8" (410mm)
16-7/8" (430mm)
18-1/4" (465mm)
19-5/8" (500mm)
21-3/8" (545mm)
2/12
4/12
6/12
8/12
10/12
12/12
16-1/4" (413mm)
16-7/8" (429mm)
17-7/8" (454mm)
19-1/4" (489mm)
20-7/8" (530mm)
22-5/8" (575mm)
*cross slope hole size
Table 3
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
15
Download from Www.Somanuals.com. All Manuals Search And Download.
ASHT+ and S2100+ Chimneys
AC chimney
OFFSET CHIMNEY INSTALLATION
1. Install the first elbow. Turn it in
the required direction. Fasten it to
the chimney with the three (3) 1/2"
(12mm) metal screws provided.
2. Installthenecessarylengthstoachieve
the required offset. Lock the chimney
lengths together: it is recommended
to use three (3) 1/2" (12mm) screws.
If the offset length is made of two (2)
chimneylengthsuseanoffsetsupport
halfway up the offset. If penetrating
a wall, install a wall radiation shield
(see Figure 22).
3. Useanotherelbowtoturnthechimney
vertically. Secure the elbow, using
three (3) 1/2" (12mm) screws.
4. Use a plumb-bob to line up the center
of the hole. Cut a hole for the chim-
ney in the ceiling. Frame this hole as
described previously (see Page 12).
5. From below, install a radiation shield
(Figure 17A).
1. Install the first elbow. Turn it in the
required direction. To lock it in place,
turn1/8ofaturn. Fastenthestrapsat-
tachedtotheelbowtothesurrounding
framing using nails or drywall screws
(Figure 20).
2. Install the necessary chimney lengths
toachievetherequiredoffset. Lockthe
chimneylengthstogether. Ifpenetrat-
ing a wall, use a wall radiation shield
(Figure 22).
3. Useanotherelbowtoturnthechimney
vertically. Lock it to the chimney.
Fastenthestrapsattachedtotheelbow
tothesurroundingframingusingnails
or drywall screws.
4. Use a plumb-bob to line up the center
of the hole. Cut a hole for the chim-
ney in the ceiling. Frame this hole as
described previously.
The minimum chimney height (including
the fireplace) when using elbows is:
Fireplace
ME43BK SP
Model
Chimney Model 8" ASHT+/S-2100+/AC
Vertical
Installation
15 feet (4.57 m)
Two (2) Elbows
Four (4) Elbows
Table 4
18 feet (5.49 m)
20 feet (6.10 m)
After reaching the location requiring the
elbow, proceed as follows:
5. From below, install a radiation shield
(see Figure 17B).
6. Continue with the regular installa-
tion.
6. A support (ST+ or SO+) must be used
on the first 15’ section (5 m).
7. Continue with the regular installa-
tion.
Note: An AC8SB starting section must be
used before installing an elbow.
16
Download from Www.Somanuals.com. All Manuals Search And Download.
Table 5
17
Download from Www.Somanuals.com. All Manuals Search And Download.
ANGLED WALL RADIATION SHIELD
(RSM+, RSMI30, RSMI45)
CHIMNEY AC
AIR COOLED
When traversing a combustible wall with the
chimneyata30°or45°angle,anangledfirestop
and/or wall radiation shield must be installed.
Only one is required (Figure 22). Table 6 gives
recommended hole size for installing a wall
radiation shield.
ACRS
(RADIATION
SHIELD)
BRACE
STRAPS
Note: 45° angle installation for Canada
only.
STRAPS
In cold climate locations, we recommend that
youusetheinsulatedwallradiationshieldsince
it will maintain the home’s thermal barrier.
SUPPORT
RSM+ and RSMI30, RSMI45
Chimney Angle
Model
Hole Size
ASHT+
30º
14-3/8" x 36-1/2”
(365mm x 927mm)
8" I.D.
Canada
45º
14-3/8" x 24-3/4”
(556mm x 629mm)
Only
S-2100+
30º
16" x 40”
(406mm x 1016mm)
8" I.D.
Figure 20
Canada
45º
16" x 27-1/4”
(406mm x 692mm)
Only
AC
8" I.D.
15-1/4" x 38-1/4”
(365mm x 927mm)
RAIN CAP
30º
STORM COLLAR
ROOF SUPPORT
Table 6
INSULATED WALL
FLASHING
INSULATED
WALL
DRYWALL
OFFSET SUPPORT
ANGLED INSULATED
WALL RADIATION SHIELD
FRAME 2” X 4”
ANGLE WALL RADIATION SHIELD
(INSULATED)
Figure 22
NOTE: IN COLD FREGIONS IT IS
RECOMMEDNED TO ENCLOSE THE
CHIMNEY IN AN INSULATED CHASE
Figure 21
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
18
Download from Www.Somanuals.com. All Manuals Search And Download.
UNIVERSAL ROOF SUPPORT INSTALLATION
CHIMNEY CHASE AND MULTIPLE
TERMINATIONS
This support has three possible uses:
Forthepurposeofthismanual,achimneychase
is considered a part of the chimney system
rather than part of a building. The termination
must be placed a minimum of 18" (460mm)
above the chase.
1. For ASHT+ and S-2100+ chimneys, it must be used on a roof to support the chimney.
2. It may be used on a floor, ceiling or roof above an offset to support the chimney above the
offset.
3. It may be used on a floor, ceiling or roof as a supplementary support when the chimney height
exceeds 15 feet (4.6 m.).
For installation where more than one chimney
is located in the same chase or within the same
general area, we suggest that their termina-
tions be separated by at least 16" (410mm)
horizontally and 18" (460mm) vertically. This
separation is to prevent smoke migrating from
one chimney to another (see Figure 23).
Table 7 gives maximum height of supported chimney.
NOTE: For the AC chimney, a support section (AC8SL) must be used every 40’ (12 m) instead
of the ST.
For roof support installation, refer to the instructions provided with the support.
UNIVERSAL OFFSET SUPPORT INSTALLATION
This support is used to support the chimney above an offset. When the chimney offset is used
to traverse a wall, this support may be used on the wall to support the chimney. The maximum
heights are given in Table 7. For offset support installation, refer to the instructions provided
with the support.
Maximum Height Of Supported Chimney
Chimney Model
offset support
20 feet (6.10 m)
14 feet (4.30 m)
40 feet (12.19 m)
roof support
24 feet (7.32 m)
16 feet (4.87 m)
50 feet (15.20 m)
ASHT+ 8" I.D.
S-2100+ 8" I.D.
AC 8" I.D.
Table 7
18" (460mm)
18" (460mm)
18" (460mm)
16"
(410mm)
16"
(410mm)
Figure 23
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
19
Download from Www.Somanuals.com. All Manuals Search And Download.
ME43 COMPONENTS LISTS
Installation Accessories
Description
Forced Air Heating Kit
Starter Kit: For wall or furnace installations. Includes BISFWK-1
blower (BISZY), flex adaptor and two clamps (BISAF),
blower variable speed control (VRUW), thermo disc (VTU),
blower flex adaptor (BISAVF), and back draft damper
(BISBD)
Cat./ Part No.
Outside Air Kit (Required - included with fireplace)
Outside Air Coupler to connect outside air UZI to fireplace,
UZIAD
UZIDF
Flex - choose 15 feet or 25 feet depending on installation
Outside Air Ducting - includes 4" insulated flex x 10' long,
UZI
UZI
Flex 5 inches ID x 15 feet Long
Flex 5 inches ID x 25 feet Long
5FLEX15
5FLEX25
Fireplace Options
Trim Kit - Gold
Starter Kit Separate Components
H3426
H3395
H3393
H3394
UZY5
Blower flex adaptor, includes damper (BISBD)
Blower - 2 50 CFM
BISAVF
BISZY
Trim Kit - Brushed Nickel
Door Capping - Gold
Flex adaptor and two clamps for fireplace connection
Blower motor speed control
BISAF
VRUW
VTU
Door Capping - Brushed Nickel
Blower
Thermo disc - turns motor on when fireplace hot and off
when cool
Back draft damper - prevents air blowing from furnace into
fireplace
BISBD
HCTW
Blower motor speed control
VRUW
Options
Fireplace Model ME43 - Approved Venting Components
Heating/Cooling thermostat - 110 volt
- 8” diameter chimney - Model ASHT+, S-2100+, HT6000+, HT6103+
or AC manufactured by Security Chimneys International only.
Notes:
TM
rojet NovaTemp ) HT6000+ is equivalent to S-2100+
(Projet NovaTemp ) HT6103+ is equivalent to ASHT+
(P
1.
2.
3.
TM
This appliance is equiped with the ASHT Chimney Adaptor. When other
chimney is used, a chimney adaptor for that chimney will be required.
Chimney Adaptor (S-2100+ / HT6000+) for CANADA ONLY - If you want to
install a S-2100+ / HT6000+ chimney, an adaptor is available (8UCA).
AC Chimney is Not recommended at elevations above 4000 feet or
in cold climates where temperatures are likely to fall below 32°F (0°C).
When using AC chimney, an AC8SB starter section must be used
before installing an elbow. When an offset is needed immediately off the
4.
5.
top of the fireplace, a starter section
(AC8SB30) is available.
20
Download from Www.Somanuals.com. All Manuals Search And Download.
ME43 COMPONENTS LISTS
TM
Secure Temp
High Temp. Insulated Stainless Steel Chimney
AC Chimney
(Air Cooled - 8” I.D.,13” O.D.)
ASHT+
8”
Diameter, Listed to CAN/UCL-S604 & UL-103HT at 2100 F
Description
Part/Cat. No.
Description
Cat./Part No.
AC Starter Adaptors
An AC Adaptor Is Needed To Convert Fireplace For Use With AC Chimney
Lengths & Misc. Chimney Components
8” length, 8” Dia., 8L8
12” length, 8” Dia., 8L12
18” length, 8” Dia., 8L18
24” length, 8” Dia., 8L24
36” length, 8” Dia., 8L36
48” length, 8” Dia., 8L48
8L8
8L12
8L18
8L24
8L36
8L48
8LA
Starter Section (adaptor), 8” AC,AC8SB
Starter 30 Elbow, 8” AC, AC8SB30
H3801
H3802
Outside Air Kit
Required for AC chimney installation
Chimney Outside Air kit (Flex, Insulation, Outside
Register and coupling), ACZI
H1967
Lengths & Misc. Chimney Components
18” Length, Dia. x 12” Long, AC6L18
8”
H3798
H3799
H3800
Adjustable Length
Dia., 8LA
12”, 8”
36” Length, 8” Dia. x 36” Long, AC8L36
elbow, Dia., 8E15
8”
8E15
8E30
8CC
15
30
48” Length, Dia. x 48” Long, AC8L48
8”
elbow, Dia., 8E30
8”
15 Elbow, 8” Dia., AC8E15
H3795
H3796
H3794
PE
Rain Termination Cap, Dia., 8CC
8”
8”
30 Elbow, Dia., AC8E30
Wall Band
BM
Rain Termination Cap, Dia., AC8CPR
8”
Supports
Spark Arrester Screen (universal spark arrester band), PE+
Wall Band, BM
H0484
Offset Support, SO
Roof Support, ST
Roof Brace, BS2
SO
ST
Supports
Offset Support, SO
H0480
H3804
H0482
H0483
BS2
Support Section, AC8SL
Roof Support, ST
Firestops
Telescopic Attic Radiation Shield, 8TRS
Firestop, 8BF
8TRS
8BF
Roof Brace, BS2
Roof Flashings
Radiation Shield, 8RS
8RS
Flat roof flashing, ACF
H0494
H0495
H0496
H0500
Insulated Attic Radiation Shield, 8RSA
Insulated Wall Radiation Shield, 8RSM
8RSA
8RSM
1/12 - 7/12 (5 - 30 ), AC, Adj. Roof Flashing, FA
8/12 - 12/12 (30 - 45 ), AC,Adj. Roof Flashing, FB
Storm collar, ACFC
Roof Flashings
Misc.
Flat Roof Flashing, 8FR
8FR
8FAR
8FBR
8FC
Telescopic attic radiation shield, ACRST
Firestop, ACBF
H0498
H0485
H0486
1/12 - 7/12 (5 -
8/12 - 12/12 (30
Storm Collar, 8FC
), 8FAR
30
-
), 8FBR
45
Radiation Shield, ACRS
21
Download from Www.Somanuals.com. All Manuals Search And Download.
ME43 COMPONENTS LISTS
APPENDIX
SPECIFICATIONS
Attic Radiation Shield, ACRSA
H0487
ACRSM30
H0489
Weight
Height
Width
343 lbs
42"
43"
Wall Radiation Shield, 30 , AC, RSM30
Insulated Wall Radiation Shield, 30 , ACRSMI30
Depth
26-5/8"
8.75 lb/feet
13.2 lb/feet
3.75 lb/feet
Chimney Outside Air Kit (Flex, Insulation, Outside
Register And Coupling), ACZI
H1967
Chimney weight ASHT+
Chimney weight S-2100+
Chimney weight AC
Notes: AC Chimney is Not recommended at elevations above 4000 feet
or in cold climates.
CLEARANCE TO COMBUSTIBLES
Replacement Parts
Description
Part/Cat. No.
PR-SR2028
PR-SR2027
PR-SR2025D
The following clearances meet the minimum requirements for a
safe installation :
Refractory
Side wall:
Ceiling:
18" (457mm)
7 feet (2135mm)
measured from the base
of the fireplace
Back refractory
Right side refractory
Fireplace enclosure:
Bottom: 0"
Side: 0"
Back: 0"
Left side refractory
Bottom refractory
PR-SR2025G
PR-SR1722
PR-SR2026
PR-HELS43
Top: Do not fill the space
above the fireplace with
any material (7 feet
measured from the base
of the fireplace)
Front refractory ash lip
Log Support Grate
Top louver
PR-SR15P
Chimney:
Mantel:
2" (50mm)
48" (1219mm) from the
base of the fireplace
Bottom louver
Louver hinges
PR-SR15P
PR-PIVOT
Rigid firescreen (right)
Black door (left)
PR-PARETIND-1
PR-SR2060GNO
PR-SR2060DNO
PR-SR2060GOR
PR-SR2060DOR
PR-SAC#69
Black door (right)
Gold plated door (left)
Gold plated door (right)
Wooden handle
Ceramic glass panel
Snap disc, blower
Door gasket assembly
Damper
PR-VC10
VTU
PR-
GASKPORTEHE-1
PR-DAMPER43
Touch-up paint, black
90L73
22
Download from Www.Somanuals.com. All Manuals Search And Download.
NOTES
23
Download from Www.Somanuals.com. All Manuals Search And Download.
Normally, all parts should be ordered through your Lennox Hearth
Products distributor or dealer. Parts will be shipped at prevailing prices
at time of order.
WARRANTY
Your fireplace is covered by a limited warranty. Please read the warranty
to be familiar with its coverage.
When ordering repair parts, always give the following information:
Retain this manual. File it with your other documents for future refer-
ence.
1. The model number of the appliance.
2. The serial number of the appliance.
3. The part number.
4. The description of the part.
5. The quantity required.
PRODUCT REFERENCE INFORMATION
We recommend that you record the following important information
about your fireplace. Please contact your Lennox Hearth Products dealer
for any questions or concerns. For the number of your nearest Lennox
Hearth Products dealer, please call 1-800-9-LENNOX.
6. The installation date of the appliance.
If you encounter any problems or have any questions concerning the
installation or application of this system, please contact your dealer.
REPLACEMENT PARTS
LENNOX HEARTH PRODUCTS
1110 West Taft Avenue
Orange, CA 92865
See Page 22 for a complete replacement parts list. Use only parts sup-
plied from the manufacturer.
Your Fireplace's Model Number________________________________________
Your Fireplace's Serial Number ________________________________________
The Date On Which Your Fireplace Was Installed___________________________
Your Dealer's Name _________________________________________________
Your Dealer's Phone Number__________________________________________
The manufacturer reserves the right to make changes at any time, without notice, in design,
materials, specifications, prices and also to discontinue colors, styles and products.
Consult your local distributor for fireplace code information.
Printed in U.S.A. © 2005 by Lennox Hearth Products
1110 West Taft Avenue • Orange, CA 92865
P/N 850,027M REV. E 12/2007