INSTALLATION MANUAL
GAS DOUBLE OVEN
RANGE
Please read this guide thoroughly before installation.
LDG3017ST
LDG3016ST
LDG3037ST
LDG3036ST
LDG3036BD
LDG3015ST/SB/SW
LDG3011ST
LDG3035ST/SB/SW
LDG3031ST
(REV.08 150223)
MFL62177703
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION INSTRUCTIONS
READ ALL INSTRUCTIONS BEFORE INSTALLATION
INSTALLATION SAFETY INSTRUCTIONS (continued)
BEFORE YOU BEGIN
Remove all tape and packing materials before using the range. Dispose of all plastic bags after
unpacking the range. Never allow children to play with packing materials.
IMPORTANT SAFETY INSTRUCTIONS
Read these instructions completely and carefully. Improper installation, adjustment, alteration,
service or maintenance can cause injury or property damage. Refer to this manual. For assistance or
additional information, consult a qualified installer, service agency, manufacturer (dealer) or the gas
supplier.
This is the safety alert symbol. This symbol alerts you to potential hazards that can kill or
hurt you and others. All safety messages will follow the safety alert symbol and either the
word “WARNING” or “CAUTION”.
This symbol will alert you to hazards or unsafe practices which could
cause serious bodily harm or death.
WARNING
This symbol will alert you to hazards or unsafe practices which could
cause bodily injury or property damage.
CAUTION
WHAT TO DO IF YOU SMELL GAS
WARNING:
If the information in
• DO NOT try to light any appliance.
• DO NOT touch any electrical switch.
• DO NOT use any phone in your building.
• Immediately call your gas supplier from a
neighbor’s phone. Follow the gas supplier’s
instructions.
this manual is not followed exactly, a fire or
explosion may result causing property damage,
personal injury or death.
– DO NOT store or use combustible materials,
gasoline or other flammable vapors and liquids
in the vicinity of this or any other appliance.
• If you cannot reach your gas supplier, call
the fire department.
Installation and service must be performed
by a qualified installer, service agency or
the gas supplier.
3
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION INSTRUCTIONS
READ ALL INSTRUCTIONS BEFORE INSTALLATION
INSTALLATION SAFETY INSTRUCTIONS (continued)
- If the range is pulled away from the wall for
cleaning, service, or any other reason, ensure that
the Anti-Tip Device is properly reengaged when the
range is pushed back against the wall.
WARNING!
• ALL RANGES CAN TIP
• INJURY TO PERSONS COULD
All ranges can tip and injury could result. To prevent
RESULT
accidental tipping of the range, attach an approved
Anti-Tip device to the wall. (See “INSTALLING THE
ANTI-TIP DEVICE” in this manual.) To check if the
device is installed and engaged properly, carefully tip
the range forward. The Anti-Tip device should engage
and prevent the range from tipping over.
• INSTALL ANTI-TIP DEVICES
PACKED WITH RANGE
• SEE INSTALLATION
INSTRUCTIONS
If you pull the range out from the wall for any reason,
make sure the Anti-Tip device is engaged when you
push the range back against the wall.
• DO NOT step or sit on the door. Install the Anti-
Tip Bracket packed with range.
- The range could be tipped and injury might result
from spilled hot liquid, food, or the range itself.
WARNING!
• Avoid placing cabinets above the range. To minimize
the hazard caused by reaching over the open flames
of operating burners, install a ventilation hood over
the range that projects forward at least 5” beyond
the front of the cabinets.
• NEVER reuse old flexible connectors. The use of
old flexible connectors can cause gas leaks and
personal injury. Always use NEW flexible connectors
when installing a gas appliance.
• Your range must be installed by a qualified installer.
• The ventilation hood must be constructed of sheet
metal not less than 0.0122” thick. Install above
the cooktop with a clearance of not less than
1/4” between the hood and the underside of the
combustible material or metal cabinet.
The hood must be at least as wide as the appliance
and centered over the appliance.
Clearance between the cooking surface and the
ventilation hood surface MUST NEVER BE LESS
THAN 24 INCHES.
• Your range should be electrically grounded in
accordance with local codes or, in the absence
of local codes, in accordance with the National
Electrical Code (ANSI/NFPA 70, latest edition). In
Canada, electrical grounding must comply with
the current CSA C22.1 Canadian Electrical Code
Part 1 and/or local codes. See “ELECTRICAL
CONNECTIONS” in this manual.
• Before installing your range on linoleum or any
other synthetic floor covering, make sure the floor
covering can resist 180°F(82°C) without shrinking,
warping or discoloring. Do not install the range over
carpeting unless a sheet of 1/4” thick plywood or
similar insulator is placed between the range and
carpeting.
EXCEPTION: Installation of a listed microwave oven
or cooking appliance over the cooktop shall conform
to the installation instructions packed with that
appliance.
• Make sure the wall coverings around the range can
resist heat generated by the range up to 200°F
(93°C).
• If cabinets are placed above the range, allow a
minimum clearance of 30” between the cooking
surface and the bottom of unprotected cabinets.
desprotegidos.
• Leak testing of the appliance shall be conducted
according to the manufacturer’s instructions.
4
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION INSTRUCTIONS
READ ALL INSTRUCTIONS BEFORE INSTALLATION
INSTALLATION SAFETY INSTRUCTIONS (continued)
WARNING!
• If a 30” clearance between cooking surface and
overhead combustible material or metal cabinets
cannot be maintained, protect the underside of
the cabinets above the cooktop with not less than
1/4” insulating millboard covered with sheet metal
not less than 0.0122” thick. Clearance between
the cooking surface and protected cabinets MUST
NEVER BE LESS THAN 24 INCHES.
• The vertical distance from the plane of the cooking
surface to the bottom of adjacent overhead
cabinets extending closer than 1” to the plane of
the range sides must not be less than 18”. (See
the Dimensions and Clearances illustration in this
manual.)
CAUTION
• Items of interest to children should not be stored
in cabinets above a range or on the backsplash of
a range—children climbing on the range to reach
items could be seriously injured.
• DO NOT attempt to operate the oven of this range
during a power failure.
IN THE COMMONWEALTH OF MASSACHUSETTS
• This product must be installed by a licensed plumber or
gas fitter.
• When using a flexible gas connector, it must not exceed
3 feet in length.
• When using ball type gas shut-off valves, they shall be
the T-handle type.
PREPARING FOR INSTALLATION
TOOLS YOU WILL NEED
MATERIALS YOU MAY NEED
• Gas line shut-off valve
• Pipe joint sealant that resists action of natural and LP gases.
Phillips screwdriver
Flat-blade screwdriver
Pencil and ruler
• Flexible metal appliance connector (3/4” or 1/2” NPT x 1/2”
I.D.)
Never use an old connector when installing a new range.
Open-end or
adjustable wrench
• Flare union adapter for connection to gas supply line (3/4” or
1/2” NPT x 1/2” I.D.)
• Flare union adapter for connection to pressure regulator on
range (1/2” NPT x 1/2” I.D.)
Pipe wrench(2)
(one for support)
• Liquid leak detector or soapy water.
• Lag bolt or 1/2” O.D. sleeve anchor (for concrete floors only).
Level
5
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION INSTRUCTIONS
DIMENSIONS AND CLEARANCES
Provide proper clearances between the range and
adjacent combustible surfaces. These dimensions must
be met for safe use of your range. The location of the
electrical outlet and pipe opening (see “GAS PIPE AND
ELECTRICAL OUTLET LOCATIONS”) may be adjusted to
meet specific requirements.
The range may be placed with 0” clearance (flush) at the
back wall.
INSTALLATION
CLEARANCES
Maximum
depth for
cabinets above
coutertops
Minimum to
cabinets on
30”
either side
of the range
30”
Minimum
13”
5”
5”
Minimum
clearance to
left wall
Minimum clearance to
right wall
18”
Front edge of
the range side
panel forward
from cabinet
36”
1/4”
0”
To cabinets
below cooktop
and at the
range back
Depth with door closed (includes door handle)
DIMENSIONS
283 4”
/
30”
36” 1/4”
Height
477 16”
/
Depth with door open.
435 32”
/
6
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION INSTRUCTIONS
LOCATION
Do not locate your range where it may be subject to
When the floor covering ends at the front of the range,
strong drafts. Any openings in the floor or wall behind
the range should be sealed. Make sure the openings
around the base of the range that supply fresh air
for combustion and ventilation are not blocked by
carpeting or woodwork.
the area that the range will be installed on should be
built up with plywood to the same level or higher than the
floor covering. This will allow the range to be moved for
cleaning and servicing, as well as proper air flow to the
range.
Your range, like many other household units, is heavy and
can be installed on soft floor coverings such as cushioned
vinyl or carpeting. Use care when moving the range on
this type of flooring.
It is recommended that the following simple and
inexpensive instructions be followed to protect your floor.
Also, make sure the floor covering can resist 180°F (82°
C). See the "INSTALLATION SAFETY INSTRUCTIONS"
(included in this manual).
Make sure the wall coverings around your range can
resist the heat generated (up to 200°F/93°C) by the range.
See the "INSTALLATION SAFETY INSTRUCTIONS"
(included in this manual).
This appliance must not be installed with a ventilation
system that blows air downward toward the range.
This type of ventilation system may cause ignition and
combustion problems with the gas cooking appliance
resulting in personal injury or unintended operation.
7
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION INSTRUCTIONS
GAS PIPE AND ELECTRICAL OUTLET LOCATIONS
30”
30”
91 16
”
/
113 32
2”
/
”
Recommended area for 120V outlet
on rear wall and area for through-
the wall connection of pipe stub and
shut-off valve.
819 32”
/
3”
145 16”
/
23
/
8”
Recommended area for through-
the floor connection of pipe stub
and shut-off valve.
1. PROVIDE ADEQUATE GAS SUPPLY
Your range is designed to operate at a pressure of
5” of water column on natural gas or 10” of water
column on LP.
For LP gas, the pressure supplied to the regulator must be
between 10” and 13” of water column. When checking for
correct operation of the regulator, the inlet pressure must
be at least 1” more than the operating (manifold) pressure
as given above.
Make sure you are supplying your range with the type of
gas for which it is configured.
The pressure regulator located at the inlet of the range
must remain in the supply line regardless of which type of
gas is being used.
This range is convertible for use on natural or LP gas.
When using this range on LP gas, conversion must be
made by a qualified LP installer before attempting to
operate the range.
A flexible metal appliance connector used to connect the
range to the gas supply line should have an I.D. of 5/8”
and a max of 5ft. In Canada, flexible connectors must be
single wall metal connectors less than 6 feet in length.
For proper operation, the pressure of natural gas supplied
to the regulator must be between 5” and 13” of water
column.
8
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION INSTRUCTIONS
2. CONNECT THE RANGE TO GAS
Shut off the range gas supply valve before removing
the old range and leave it off until the new hook-up
has been completed.
Connect a flexible metal appliance connector to
the adapter on the range. Position range to permit
connection at the shut-off valve.
C
Because hard piping restricts movement of the range,
the use of a CSA International-certified flexible metal
appliance connector should be used unless local codes
require a hard-piped connection.
When all connections have been made, be sure all
range controls are in the off position and turn on the
main gas supply valve. Gas leaks may occur in your
system and result in a dangerous situation. Gas leaks
may not be detected by smell alone.
D
NEVER reuse an old connector when installing a new
range.
Check all gas connection joints and fittings for leaks
with a non-corrosive leak detection fluid, then wipe off.
To protect against gas leaks, use a qualified pipe joint
sealant on all external threads.
Gas suppliers recommend you purchase and install
an UL approved gas detector. Install and use in
accordance with Installation instructions.
Install male 1/2” or 3/4” flare union adapter to the NPT
A
internal thread of the manual shut-off valve, taking
care to back-up the shut-off valve to keep it from
turning.
WARNING!
DO NOT USE A FLAME TO CHECK FOR GAS
LEAKS.
Install male 1/2” flare union adapter to the 1/2” NPT
B
internal thread at inlet of pressure regulator. Use a
backup wrench on the pressure regulator fitting to
prevent damage.
WARNING!
Isolate the range from the gas supply system by
closing its individual shut-off valve during any pressure
testing of the gas supply system at test pressures
equal to or less than 1/2” psig(3.5kPa).
In a emergency situation or if you want to shut off
the gas suppluy, remove the packing rubber from the
regulator in the backside, and then close the regulator's
valve by positioning the lever as shown in the figure.
Lever’s open position
Lever’s open position
(without rubber O-ring)
Lever’s close position
FLEXIBLE CONNECTOR HOOKUP
Adapter
Gas Flow into Range
Pressure regulator
Flex connector
(6 ft. max.)
Adapter
Installer: Inform the
consumer of the
location of the gas
shut-off valve
Gas shut-off valve
1/2” or 3/4”
Gas pipe
9
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION INSTRUCTIONS
3. ELECTRICAL CONNECTIONS
ELECTRICAL REQUIREMENTS
120 Volt, 60 Hertz, properly grounded dedicated circuit protected by a 15 or 20 Amp circuit breaker, or slow blow fuse.
GROUNDING
IMPORTANT: FOR PERSONAL SAFETY, THIS APPLIANCE MUST BE PROPERLY GROUNDED.
The power cord of this appliance is equipped with a 3-prong
(grounding) plug which mates with a standard 3-prong
grounding wall receptacle to minimize the possibility of electric
CAUTION:
The customer should have the circuit checked by a
qualified electrician to make sure the receptacle is
properly grounded.
shock hazard from this appliance.
The customer should have the wall receptacle and circuit
checked by a qualified electrician to make sure the receptacle
is properly grounded.
DO NOT use an adapter plug because disconnecting of the
power cord places undue strain on the adapter and leads to
eventual failure of the adapter ground terminal.
Where a standard two-prong wall receptacle is encountered,
it is the personal responsibility and obligation of the customer
to have it replaced with a properly grounded three-prong wall
receptacle.
The installation of appliances designed for mobile home
installation must conform with the Manufactured Home
Construction and Safety Standard, Title 24 CFR, Part 3280
(formerly the Federal Standard for Mobile Home Construction
and Safety, Title 24, HUD, Part 280) or, when such standard
is not applicable, the Standard for Manufactured Home
Installations, latest edition (Manufactured Home Sites,
Communities and Set-Ups), ANSI A225.1, latest edition, or
with local codes. In Canada, mobile home installation must
be in accordance with the current CAN/CSA Z240/MH Mobile
Home Installation Code.
DO NOT, UNDER ANY CIRCUMSTANCES, CUT OR
REMOVE THE THIRD (GROUND) PRONG FROM THE
POWER CORD.
A word about GFCI’s – GFCI’s are not required or
recommended for gas range receptacles.
Ground Fault Circuit Interrupters (GFCI’s) are devices that
sense leakage of current in a circuit and automatically switch
off power when a threshold leakage level is detected. These
devices must be manually reset by the consumer. The
National Electrical Code requires the use of GFCI’s in kitchen
receptacles installed to serve countertop surfaces.
WARNING!
Performance of the range will not be affected if operated on a
GFCI-protected circuit but occasional nuisance can occur.
POWER MUST BE DISCONNECTED BEFORE
SERVICING THE APPLIANCE. FAILURE TO DO SO
CAN RESULT IN DEATH OR ELECTRICAL SHOCK.
PREFERRED
METHOD
Ensure proper ground
exists before use
4. SEAL THE OPENINGS
Seal any openings in the wall and floor after electrical and gas supplies are completed.
10
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION INSTRUCTIONS
5. ASSEMBLE THE SURFACE BURNERS
CAUTION
DO NOT Operate the burners without all parts in
Hole
place.
Place the burner caps and heads on the cooktop. Make
sure that the caps and heads are placed in the correct
locations. There is one small, one medium, one large and
one extra large burner head and cap.
Electrode
Make sure the hole in the burner head is positioned over
the electrode.
Center Burner
(on some models)
Medium burner
head and cap
(on some models)
Oval (Center) Burner
Head/Cap Assembly
Small burner
head and cap
Medium
burner
head and
cap
(on some (on some
models) models)
Front of range
Large burner
head and cap
Extra large burner
head and cap
6. CHECK IGNITION OF SURFACE BURNERS
ELECTRIC IGNITION
QUALITY OF FLAMES
Select a top burner knob and simultaneously push in and
turn to the “LITE” position. You will hear a clicking sound
indicating proper operation of the spark module.
The combustion quality of burner flames needs to be
confirmed visually.
A Yellow flames—Call for service
Once the air has been purged from the supply lines,
burner should ignite within 4 seconds. After burner ignites,
rotate knob out of the “LITE” position. Try each burner in
succession until all burners have been checked.
B Yellow tips on outer cones—
It is normal for LP gas
C Soft blue flames—
It is normal for natural gas
With LP gas, some yellow tipping on outer cones is
normal.
11
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION INSTRUCTIONS
7. ADJUST THE SURFACE BURNER TO THE LOW
FLAME(SIMMER) SETTING.
1) Light all surface burners.
2) Turn the knob on the burner being adjusted to “LO”.
3) Remove knob.
4) Insert a small, flat bladed screwdriver into the valve
shaft as shown in Fig. 1.
On right front valve for model LDG3019ST there is a
secondary adjustment for the low flame for the outer
burners.
Insert a small, flat blade screwdriver into the hole
next to the valve stem to adjust the outer flame as
shown in Fig. 2.
Center adjustment screw Adjustment screw next
to the valve shaft
Fig. 1
Fig. 2
6) Test the flame stability.
Turn the adjustment screw until the flame reaches
the desired size.
Test 1: Turn the knob from “HI” to “LO” quickly. If the
flame goes out, increase the flame size and test again.
5) Replace the knob.
Test 2: With the burner on a “LO” setting, open and
close the oven door quickly. If the flame is extinguished
by the air currents created by the door movement,
increase the flame height and test again.
Note: Hold the valve shaft with one hand while turning
the screw for adjustment with the other.
7) Repeat steps 1-6 for each surface burner.
12
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION INSTRUCTIONS
8. CHECK OPERATION OF BAKE/BROIL BURNERS
To check ignition of the Bake burner, follow the steps
below:
To check ignition of the Broil burner, follow the steps
below:
1) Remove all packing from inside the oven cavity.
2) Press "Bake" (350 will be shown in the display).
3) Press Start.
1) Press "Broil" ("Hi" will be shown in the display).
2) Make sure the door is closed.
3) Press Start.
It may take between 30 and 90 seconds for the burner
to start heating.
It may take between 30 and 90 seconds for the burner
to start heating.
NOTE: Do not try and light either the bake or broil
burners during a power outage. The range has an
electrical ignition system and can not be used
without power.
9. AIR SHUTTER ADJUSTMENT FOR BAKE AND BROIL
BURNERS.
The range comes from the factory with air shutters adjusted for proper air flow for natural gas.
If converted to LP, follow the instructions provided in the conversion kit to properly adjust the air shutters.
LP conversion must be performed by a qualified technician.
13
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION INSTRUCTIONS
10. INSTALLING THE ANTI-TIP DEVICE
INSTALL THE BRACKET USING THE BRACKET
INSTALLATION SHEET
WARNING
• Range must be secured with an approved Anti-
Tip device.
Anti-tip
bracket
Wall plate
• The range could be tipped by standing, sitting or
leaning on an open door if the range or Anti-Tip
device is not properly installed.
Screw must
enter wood or
concrete
• After installing the Anti-Tip device, verify that
it is in place by carefully attempting to tilt the
range forward.
The Anti-tip bracket is packaged with an installation
template.
The instructions include necessary information to
complete the installation.
• This range has been designed to meet all
recognized industry tip standards for all normal
conditions.
• The installation of the Anti-Tip device must meet
all local codes for securing the appliance.
Read and follow range installation instruction sheet.
• The use of this device does not preclude tipping
of the range when not properly installed.
11. LEVELING THE RANGE
Install the oven shelves in the oven and locate the
range where it will be installed.
A
Spirit level
Check if the range is level by placing a spirit level or
B
a cup, partially filled with water, on one of the oven
shelves. If using a spirit level, take two readings—
with the level placed diagonally first in one direction –
① and then the other –②.
Remove the lower door. See the “CARE AND
C
CLEANING OF THE RANGE” section in the owner's
manual. The front and rear leveling legs can be
adjusted from the bottom.
Use an open-end or adjustable wrench to adjust the
leveling legs until the range is level.
D
Lower
range
Leg leveler
Raise
range
14
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION INSTRUCTIONS
WHEN ALL HOOKUPS ARE COMPLETE
Make sure all controls are left in the off position. Make sure the flow of combustion and ventilation air to the
range is unblocked.
CONVERTING TO LP GAS
(OR CONVERTING BACK TO NATURAL GAS FROM LP)
This range leaves the factory set for use with natural
gas. The conversion to LP gas must be performed by
a qualified LP gas installer when converting to LP gas.
The conversion instructions and LP orifices can be found
attached to the range on the back.
Keep these instructions and the orifices in case you want
to convert back to natural gas.
15
Download from Www.Somanuals.com. All Manuals Search And Download.
Memo
Download from Www.Somanuals.com. All Manuals Search And Download.
|