Kramer Electronics, Ltd.
USER MANUAL
Model:
FC-1ETHN
Ethernet Controller
Download from Www.Somanuals.com. All Manuals Search And Download.
Contents
Tables
Table 1: Terminology Used in this User Manual
2
3
6
Table 2: Features and Functions of the FC-1ETHN Ethernet Controller
Table 3: FC-1ETHN Configuration Manager Window Functionality
Table 4: Crossover Cable RJ-45 PINOUT
8
Table 5: Straight-through Cable RJ-45 PINOUT
8
Table 6: Technical Specifications of the FC-1ETHN Ethernet Controller
16
ii
KRAMER ELECTRONICS, LTD.
Download from Www.Somanuals.com. All Manuals Search And Download.
ADDENDUM: FC-1ETHN
This addendum describes an upgrade to the FC-1ETHN: the Virtual Serial Port.
Amendment to Section 3
The following text on page 2 is deleted:
ñ
Is compatible with the latest Kramer K-Router Windows®-based control
software (version 4.0 or higher) whose user-friendly interface now allows
Kramer switchers to be controlled via Ethernet
The following text is inserted immediately prior to section 3.1:
The FC-1ETHN now includes the Virtual Serial Port Driver for compatibility
with applications based on COM-port communication. The Virtual Serial Port:
ñ
Makes the FC-1ETHN compatible with all Windows®-based
applications which work through an actual COM port. This includes all versions
of K-Router and other Kramer control applications. It lets you operate all RS-232
and RS-485 controllable devices via Ethernet LAN using their existing PC
software
ñ
Operates like an actual hardware port, that is, a logical COM that behaves
like a standard hardware COM but in reality transparently reroutes the data using
the TCP/IP network to the FC-1ETHN interface via a Virtual Null-modem
connection, which you can emulate over the Ethernet or Internet
ñ
Can be created in any quantity on your PC and does not occupy an actual
serial port
Amendment to Section 5
In Table 3: “FC-1ETHN Configuration Manager Window Functionality” (on page 6),
item 6 is replaced as follows:
6
Serial Setting In the serial setting speed list, click the appropriate baud speed1 (1200, 2400, 4800, 9600,
19200, 38400, 57600).
Note: the FC-1ETHN does not support 115200 baud rate.
Amendment to Section 6
The following new section, section 6.4 “Configuring the FC-1ETHN via its Virtual Port”,
is inserted immediately prior to section 7:
To configure the FC-1ETHN via the Virtual Port, do the following:
ñ
Download the Virtual Serial Port Driver at this URL:
instructions:
1 The configuration baud is factory preset, and fixed, at 9600
P/N: 2900 – 1040202
A1
Download from Www.Somanuals.com. All Manuals Search And Download.
ADDENDUM: FC-1ETHN
Figure A1: Virtual Serial Port Manager
Amendment to Section 7
Figure A2: Virtual Serial Port Properties
In section 7.1 (on page 11) steps 5, 6, and 7 are replaced by the following:
5. Connect the ETHERNET port of your FC-1ETHN to a LAN, using a
straight-through cable with RJ-45 connectors.
You can control from up to three computers (each with the Kramer
Windows®-control software).
6. Run the Kramer Windows®-control software to control the Kramer
machine from each computer.
When working with a non-Kramer device, use their existing PC software
or the Microsoft HyperTerminal.
7. In the K-Router Port window, choose the COM port according to the
number of your virtual Serial port:
In section 7.1 (on page 11) Figure 6 is replaced by the following:
Figure A3: Choosing the COM Port
KRAMER: SIMPLE CREATIVE TECHNOLOGY
A2
Download from Www.Somanuals.com. All Manuals Search And Download.
ADDENDUM (this data is included at the end of the Overview section)
This addendum adds the following information to the user manual:
Caution – No operator-serviceable parts inside unit.
Warning – Use only the Kramer Electronics input power
wall adapter that is provided with this unit1.
Warning – Disconnect power and unplug unit from wall
before installing or removing device or servicing unit.
1 For example: model number AD2512C, part number 2535-000251
2900-9999992
A1
Download from Www.Somanuals.com. All Manuals Search And Download.
ADDENDUM: Ethernet Cross Cable Wiring Connection
This addendum describes the correct wiring for crossover cable connections
and replaces the opening paragraph in the "Connecting the ETHERNET Port
directly to a PC (Crossover Cable)" section in the User Manual as follows:
Connecting the ETHERNET Port directly to a PC (Crossover Cable)
You can connect the Ethernet port of the machine to the Ethernet port on your
PC, via a crossover cable with RJ-45 connectors.
Table 1 and Figure 1 define the color codes for the two existing standard types
of cross cables used in the industry. Table 2 defines how to connect the wires
to the connectors on both ends of the cable.
When manually connecting the ends of a cable, both connectors must follow
the same standard (either EIA /TIA 568A or EIA /TIA 568B).
Table 1: Crossover Cable RJ-45 Types
1
8
EIA /TIA 568B
EIA /TIA 568A
Wire Color
White-green
Green
PIN Wire Color
PIN
1
1
2
3
4
5
6
7
8
White-orange
Orange
TOP
2
White-green
Blue
3
White-orange
Blue
4
White-blue
Green
5
White-blue
Orange
6
FRONT
White-brown
Brown
7
White-brown
Brown
8
1
8
Figure 1: RJ-45 PINOUT
Table 2: Wiring between Connector One and Two of the Cable
Signal Pairs
PINs on
Connector One
PINs on Connector
Two
Signal Pairs
TX_D1+
TX_D1-
RX_D2+
RX_D2-
BI_D3+
BI_D3-
1
2
3
6
4
5
7
8
3
6
1
2
7
8
4
5
RX_D2+
RX_D2-
TX_D1+
TX_D1-
BI_D4+
BI_D4-
BI_D4+
BI_D4-
BI_D3+
BI_D3-
P/N: 2900 - 9999993
Download from Www.Somanuals.com. All Manuals Search And Download.
A1
Introduction
1
Introduction
Dedication by Kramer Electronics since 1981, to the development and
manufacture of high quality video/audio equipment, makes the Kramer line
an integral part of the finest production and presentation facilities in the
world. In recent years, Kramer has redesigned and upgraded most of the line,
making the best even better! The Kramer line of professional video/audio
electronics is one of the most versatile and complete available, and is a true
leader in terms of quality, workmanship, price/performance ratio and
innovation. In addition to the FC-1ETHN Ethernet Controller, we also offer
excellent switchers and matrices, distribution amplifiers, presentation
processors, interfaces, remote controllers and computer-related products.
Congratulations on purchasing your Kramer TOOLS FC-1ETHN Ethernet
Controller, which is ideal for use with Ethernet / RS-232 interface and
Ethernet / RS-485 interface. The package includes the following items:
•
•
•
•
•
FC-1ETHN Ethernet Controller
Power adapter (12V DC Input)
Windows®-based control software, and Configuration Manager software
Null-modem adapter
This user manual1 and the Kramer concise product catalog/CD
2
3
Getting Started
We recommend that you:
•
Unpack the equipment carefully and save the original box and packaging
materials for possible future shipment
•
•
Review the contents of this user manual
Use Kramer high performance high resolution cables2
Overview
The high performance FC-1ETHN Ethernet Controller—an upgrade on the
FC-1ETH—is an easy-to-use, compact, bi-directional hardware and software
interface system for controlling most Kramer RS-232 and/or RS-485
controllable machines via Ethernet LAN, as well as via the Internet.
in the Products section)
1
Download from Www.Somanuals.com. All Manuals Search And Download.
Overview
In particular, the FC-1ETHN:
Offers network connectivity that lets you connect a Kramer (or other)
device via its RS-232 or RS-485 port to the Ethernet LAN network
Lets you control an RS-232 / RS-485 device via Ethernet, from a PC (set
to Slave routing mode) or other protocol compatible remote controller1
Lets you control a device from up to three Ethernet points (PCs or remote
controllers)
•
•
•
•
Includes Windows®-based Configuration Management software for serial
and network programming (including routing mode settings, network settings,
serial settings, and destination device settings)
•
Is compatible with the latest Kramer K-Router Windows®-based control
software (version 4.0 or higher) whose user-friendly interface now allows
Kramer switchers to be controlled via Ethernet
•
Supports easy dial-up and Internet system remote control (requiring only
a dedicated IP address and a modem in the remote location) whether it is a
standalone PC or a LAN system
•
•
Supports using wireless, 802.11b standard based LAN systems for control
Has capability to facilitate a built-in Web page server
3.1 Terminology Used in this User Manual
Table 1 defines some terms that are used in this user manual:
Table 1: Terminology Used in this User Manual
Term
Definition
802.3
The standard specification for ETHERNET that is maintained by the Institute of
Electrical and Electronics Engineers (IEEE).
Dynamic Host
Allows the network administrator to distribute IP addresses from a central point
Configuration Protocol and automatically send a new IP address when an Ethernet point is plugged
(DHCP)
into a different network location.
Gateway
A network position serving as an entry to another network. On the Internet, a
node or stopping point can be either a gateway node or a host (end-point) node.
IP Address
A 32-binary digit number that identifies each sender or receiver (within a
network via a particular server or workstation) of data (HTML pages or e-mails)
that is sent in packets across the Internet.
Local Area Network
(LAN)
Computers sharing a common communications line or wireless link, which often
share a server within a defined geographic area.
Media Access Control A computer's unique hardware number in a LAN or other network. On an
(MAC) Address Ethernet LAN, the (MAC) address is identical to the Ethernet address.
Transmission Control The basic communication language or protocol of the Internet that breaks the
Protocol/Internet
Protocol (TCP/IP)
message into appropriately sized packets for the network, and can be used as a
communications protocol in an intranet or an extranet.
1 When using two FC-1ETHN units, both set to Master routing mode
2
KRAMER ELECTRONICS, LTD.
Download from Www.Somanuals.com. All Manuals Search And Download.
Your FC-1ETHN Ethernet Controller
3.2 Achieving the Best Performance
Achieving the best performance means:
Connecting only good quality connection cables, thus avoiding
•
interference, deterioration in signal quality due to poor matching, and elevated
noise levels (often associated with low quality cables)
•
Avoiding interference from neighboring electrical appliances and
positioning your FC-1ETHN away from moisture, excessive sunlight and dust
4 Your FC-1ETHN Ethernet Controller
Figure 1 and Table 2 define the FC-1ETHN Ethernet Controller:
Figure 1: FC-1ETHN Ethernet Controller
Table 2: Features and Functions of the FC-1ETHN Ethernet Controller
#
1
2
3
Feature
Function
12V DC
+12V DC connector for powering the unit
Connects to your LAN
ETHERNET port
4
3
2
1
CONFIG
485 TERM
RESET
Used to configure the system
Used to terminate the RS-485 line
Used to reset the unit
REPROG
Used to upgrade the firmware
Connects to the RS-232 DB 9 port on a Kramer (or other) device or PC
4
5
RS-232 port
A B G (RS-485) port
Connects to the RS-485 port on a Kramer (or other) device
PIN A connects to the “A” (+) PIN; PIN B connects to the “B” (–) PIN; and
PIN G connects to the “G (Ground)” PIN
6
7
8
9
ON LED
Illuminates when receiving power
Lights when the speed is 100M
Lights when the speed is 10M
100M LED
10M LED
STATUS LED
Ready for communication if one STATUS LED flashes; communication
already exists if both STATUS LEDs flash
10 STATUS LED
3
Download from Www.Somanuals.com. All Manuals Search And Download.
Using the Kramer Configuration Manager Software
5 Using the Kramer Configuration Manager Software
This section describes:
•
•
How to install and run the Configuration Manager software, see section 5.1
The Configuration Manager Window features, see section 5.2
5.1 Installing and Running the Kramer Configuration Manager Software
To install the Kramer Configuration Manager software:
•
Insert the CD-ROM in the CD-ROM drive, double click the Setup.exe file
and follow the on-screen instructions
To run the Kramer Configuration Manager software (for the first time):
1. Click the appropriate shortcut in the Start menu’s Programs folder.
The Choose Port window appears as follows:
Figure 2: Choose Port Window
2. Choose the LAN port for configuration via Ethernet, or the appropriate
COM port for configuration via serial cable (see section 6.1) and click OK.
The FC-1ETHN Configuration Manager window (see Figure 3) opens.
To run the Kramer Configuration Manager software (subsequently):
•
Click the appropriate shortcut in the Start menu’s Programs folder.
The FC-1ETHN Configuration Manager window (see Figure 3) opens
5.2 Understanding the Kramer Configuration Manager Window
Figure 3 and Table 3 define the FC-1ETHN Configuration Manager window:
4
KRAMER ELECTRONICS, LTD.
Download from Www.Somanuals.com. All Manuals Search And Download.
Using the Kramer Configuration Manager Software
Figure 3: FC-1ETHN Configuration Manager Window
5
Download from Www.Somanuals.com. All Manuals Search And Download.
Using the Kramer Configuration Manager Software
Table 3: FC-1ETHN Configuration Manager Window Functionality
#
Feature
Device List
Function
1
Displays the MAC Addresses for the FC-1ETHN devices, connected via the selected
port (LAN or COM).
2
3
Master Mode When selected, activates the Master mode (see section 6.3.2).
Check Box
DHCP1
When cleared, activates the Slave mode (see section 6.3.1).
When selected, automatically configures the FC-1ETHN to obtain an IP address from
Mode Check the network administrator via the Dynamic Host Configuration Protocol (DHCP)
Box
When cleared, manual configuration of the FC-1ETHN is required to obtain an IP
address (Static IP)
4
Network
Settings
IP Address: A 32-binary digit number obtained
from your Network Administrator that identifies the
FC-1ETHN device that is currently being
configured in the Ethernet or Internet.
For example:
Subnet: A 32-binary digit number obtained from
your Network Administrator, which combined with
the IP Address, identifies which network your
FC-1ETHN device is on.
Gateway: A network position serving as an entry
to another network or to the Internet (only relevant
in the Master Routing mode).
Local Port is an address of the FC-1ETHN device
that is currently being configured that provides a
direct route from another Ethernet point application.
5
Destination Destin. IP A 32-binary digit number that identifies For example:
Device
Settings
the destination FC-1ETHN device in the Ethernet
or Internet.
Port is a pre-assigned address of the destination
FC-1ETHN device that provides a direct route to
its Transport layer.
6
7
Serial
Setting
In the serial setting speed list, click the appropriate baud speed2 (1200, 2400, 4800,
9600, 19200, 38400, 57600, 115200).
Action
Search: seeks the FC-1ETHN devices that connect to the PC via the chosen LAN or
Buttons
COM port, and displays them and their corresponding settings.
Setting: adjusts the FC-1ETHN according to the displayed data.
8
9
Progress Bar Shows the progress
Status Bar
Shows the status
10 Exit Button
11 Version
Closes the Configuration Manager application
Displays the firmware version number
12 Menu bar
File menu’s Exit command closes the Configuration Manager application.
Action menu’s Search Board command seeks the FC-1ETHN devices that connect to
the PC via the chosen LAN or COM port, and displays them and their corresponding
settings.
Action menu’s Setting command adjusts the FC-1ETHN according to the displayed
data.
Port menu displays the Choose Port window.
Set MAC1 menu is for factory use only (click the Password command to enter the
password).
1 See definition in Table 1
2 The configuration baud is factory preset, and fixed, at 9600
6
KRAMER ELECTRONICS, LTD.
Download from Www.Somanuals.com. All Manuals Search And Download.
Configuring the FC-1ETHN Ethernet Controller
6 Configuring the FC-1ETHN Ethernet Controller
This section describes how to configure the FC-1ETHN via its:
•
•
Serial1 port, see section 6.1
ETHERNET1 port, see section 6.2
6.1 Configuring the FC-1ETHN via its Serial Port
You can configure the FC-1ETHN via its RS-232 port.
To configure the FC-1ETHN via RS-232, do the following:
1. Set the CONFIG DIP2 (DIP 4) to ON.
Leave the other three DIPs3 set to OFF.
2. Connect the RS-232 port of the FC-1ETHN to the Null-modem adapter
and connect the Null-modem adapter with a 9 wire flat cable to the
RS-232 DB9 COM port on your PC.
3. Run the Kramer Configuration Manager software (see section 5.1) and
choose the COM port that is appropriate for your computer from the
FC-1ETHN Configuration Manager window (see section 5.2).
4. Click the Search button (or the Action menu’s, Search Board command).
The MAC Address for the found “FC-1ETHN” appears in the Device List.
5. Change the settings and then click the Setting button (or the Action
menu’s, Setting command) to apply the settings.
Note: be aware that this will alter the IP settings in the FC-1ETHN.
6. Set the CONFIG DIP2 (DIP 4) to OFF.
Leave the other three DIPs3 set to OFF.
7. Disconnect the power to the FC-1ETHN, and then reconnect it.
1 The serial mode is always available even if the FC-1ETHN is not correctly setup, whereas the Ethernet mode is not a
separate mode and can proceed in parallel with the normal operation of the FC-1ETHN
2 See item 3 in Table 2
3 485 TERM (DIP 3), RESET (DIP 2), and REPROG (DIP 1)
7
Download from Www.Somanuals.com. All Manuals Search And Download.
Configuring the FC-1ETHN Ethernet Controller
6.2 Configuring the FC-1ETHN via its ETHERNET port
You can configure the FC-1ETHN via its ETHERNET port.
To configure the FC-1ETHN via ETHERNET, do the following:
1. Connect the ETHERNET port of the FC-1ETHN to the LAN port on
your PC, via a crossover cable with RJ-45 connectors, as Table 4 defines:
Table 4: Crossover Cable RJ-45 PINOUT
Side 1
Side 2
PIN Wire Color
PIN Wire Color
1
2
3
4
5
6
7
8
White-orange
Orange
1
2
3
4
5
6
7
8
White-green
Green
White-green
Blue
White-orange
Blue
White-blue
Green
White-blue
Orange
White-brown
Brown
White-brown
Brown
If connecting the ETHERNET port of the FC-1ETHN to the LAN port on
a network hub or network router, use a straight-through cable with RJ-45
connectors, as Table 5 defines:
Table 5: Straight-through Cable RJ-45 PINOUT
Side 1
Side 2
PIN Wire Color
PIN Wire Color
1
2
3
4
5
6
7
8
White-orange
Orange
1
2
3
4
5
6
7
8
White-orange
Orange
White-green
Blue
White-green
Blue
White-blue
Green
White-blue
Green
White-brown
Brown
White-brown
Brown
2. Run the Kramer Configuration Manager software (see section 5.1) and
choose the LAN port (see Figure 2).
3. Click the Search button (or the Action menu’s, Search Board command).
The MAC Address for the found “FC-1ETHN” appears in the Device List.
4. Change the settings and then click the Setting button (or the Action
menu’s, Setting command) to apply the settings.
Note: be aware that this will alter the IP settings in the FC-1ETHN.
8
KRAMER ELECTRONICS, LTD.
Download from Www.Somanuals.com. All Manuals Search And Download.
Configuring the FC-1ETHN Ethernet Controller
6.3 Routing Data in the Slave and Master Routing Modes
The FC-1ETHN routes data in either the Slave Routing Mode (see section
6.3.1) or the Master Routing Mode (see section 6.3.2).
6.3.1
Slave Routing Mode
In the Slave Routing Mode, the FC-1ETHN never sends any data in the serial
port-Ethernet direction before it first receives some data from the remote
station (that is, the data in the Ethernet-serial direction). Serial data that is
received at the serial port of the FC-1ETHN before the remote station
contacts the FC-1ETHN is discarded. In the Slave Mode, the FC-1ETHN
will work with any station on the network that contacts it (but not more than
three stations simultaneously), as the example in Figure 4 illustrates:
Figure 4: Connecting the FC-1ETHN in the Slave Routing Mode
9
Download from Www.Somanuals.com. All Manuals Search And Download.
Controlling Kramer Machines via Ethernet using the FC-1ETHN
6.3.2
Master Routing Mode
In the Master Routing Mode, the FC-1ETHN does not wait for the remote
station to send the data first, and routes the data in the destination device
direction as soon as there is data to be sent. The data is always sent to a
specific destination (as defined by the Destination IP address and Destination
Data Port Number Settings of the FC-1ETHN). Also, the FC-1ETHN only
accepts the data sent from the remote station whose IP address matches the
one set in the Destination IP address. The FC-1ETHN will discard the data
sent from any other IP. See the example illustrated in Figure 5:
Figure 5: Connecting the FC-1ETHN in the Master Routing Mode
7
Controlling Kramer Machines via Ethernet using the FC-1ETHN
You can use your FC-1ETHN to control a Kramer machine from computers
that connect to a LAN1 (see section 7.1) or via a controller1 (see section 7.2).
1 As well as via an Internet connection
10
KRAMER ELECTRONICS, LTD.
Download from Www.Somanuals.com. All Manuals Search And Download.
Controlling Kramer Machines via Ethernet using the FC-1ETHN
7.1 Controlling a Kramer Machine via a Computer
To control a Kramer machine via three computers, as the example in Figure 4
illustrates, do the following:
1. Configure the FC-1ETHN to the Slave Routing Mode (see section 6).
2. Set all the DIPs to OFF.
3. Connect the 12V DC power adapter to the power socket and connect the
adapter to the mains electricity.
4. Connect the RS-232 port of your Kramer machine to the RS-232 port of
the FC-1ETHN via a Null modem (alternatively, connect the RS-485 port
of your Kramer machine to the ABG port1 of the FC-1ETHN).
5. Connect the ETHERNET port of your FC-1ETHN to a LAN, using a
straight-through cable with RJ-45 connectors.
You can control from up to three computers (each with the Kramer
K-Router Windows®-control software (version 4.0 or higher)).
6. Run the Kramer K-Router Windows®-control software (version 4.0 or
higher) to control the Kramer machine from each computer.
Use the Microsoft HyperTerminal if working with a non-Kramer device.
7. In the K-Router Port window, click the Remote Connection option and set
the RemoteHost and RemotePort, as per the FC-1ETHN configuration:
Figure 6: Connecting the FC-1ETHN in the Master Routing Mode
1 Connect PIN A to the “A” (+) PIN, PIN B to the “B” (–) PIN, and PIN G to the “G (Ground)” PIN
11
Download from Www.Somanuals.com. All Manuals Search And Download.
Flash Memory Upgrade
7.2 Controlling a Kramer Machine via a Controller
To control a Kramer machine via two VS-3000 controllers, as the Master
Mode example in Figure 5 illustrates, do the following:
1. Configure each FC-1ETHN to the Master Routing Mode (see section 6).
2. Set all the DIPs to OFF on each FC-1ETHN.
3. Connect the RS-232 port of your Kramer machine to the RS-232 port of a
FC-1ETHN via a Null modem (alternatively, connect the RS-485 port of
your Kramer machine to the ABG port1 of the FC-1ETHN) and connect
the ETHERNET port of that FC-1ETHN to a LAN.
4. Connect the ETHERNET port of another FC-1ETHN to the same LAN
and connect the RS-232 port of the controller to the RS-232 port of that
FC-1ETHN (alternatively, connect the RS-485 port of the controller to the
ABG port1 of the FC-1ETHN).
5. Connect the ETHERNET port of another FC-1ETHN to the same LAN
and connect the RS-232 port of the controller to the RS-232 port of that
FC-1ETHN via a Null modem (alternatively, connect the RS-485 port of
the controller to the ABG port1of the FC-1ETHN).
6. On each FC-1ETHN, connect the 12V DC power adapter to the power
socket and connect the adapter to the mains electricity.
8
Flash Memory Upgrade
The FC-1ETHN firmware is located in FLASH memory, which lets you
upgrade to the latest Kramer firmware version in minutes! The process
involves:
•
•
•
Downloading from the Internet (see section 8.1)
Connecting the PC to the RS-232 port (see section 8.2)
Upgrading Firmware (see section 8.3)
8.1 Downloading from the Internet
You can download the up-to-date file from the Internet. To do so:
the file: “FLIP_ FC1ETHN.zip” from the Technical Support section.
2. Extract the file: “FLIP_ FC1ETHN.zip” to a folder (for example,
1 Connect PIN A to the “A” (+) PIN, PIN B to the “B” (–) PIN, and PIN G to the “G (Ground)” PIN
12
KRAMER ELECTRONICS, LTD.
Download from Www.Somanuals.com. All Manuals Search And Download.
Flash Memory Upgrade
C:\Program Files\Kramer Flash).
3. Create a shortcut on your desktop to the file: “FLIP.EXE”.
8.2 Connecting the PC to the RS-232 Port
Before installing the latest Kramer firmware version on a FC-1ETHN unit,
do the following:
1. Connect the RS-232 DB9 port on the FC-1ETHN to the Null-modem
adapter and connect the Null-modem adapter with a 9 wire flat cable to the
RS-232 DB9 COM port on your PC.
It is recommended that you use COM port1 2. However, if your computer has
only one COM port, open the file: “FC1ETHN.cfg” (located at C:\Program
Files\Kramer Flash\ FC1ETHN.cfg) in Notepad, and change “set port
COM2” to “set port COM1”.
2. Connect the power on the FC-1ETHN unit.
3. Set the DIP 1 REPROG to ON.
8.3 Upgrading Firmware
Follow these steps to upgrade the firmware:
1. Double click the desktop icon: “Shortcut to FLIP.EXE”.
The Splash screen appears as follows:
Figure 7: Splash Screen
2. After a few seconds, the Splash screen is replaced by the “Atmel – Flip”
window:
1 The software is preset for use with COM port 2
13
Download from Www.Somanuals.com. All Manuals Search And Download.
Flash Memory Upgrade
Figure 8: Atmel – Flip Window
3. Press the keyboard shortcut key F4 (or select the “Read Configuration
File” command from the File menu, or press the keys: Alt FR).
The “Open Configuration File” window appears:
FC1ETHN.CFG
Figure 9: Open Configuration File Select Window
4. Choose the file: “FC1ETHN.cfg” (by double-clicking it).
If COM 2 was not selected (see section 8.2), an RS-232 error message
appears. In the “Atmel – Flip” window, the Operations Flow column is
disabled, and crosses appear in the third column.
Figure 10: Atmel – Flip Window (RS-232 Communication)
14
KRAMER ELECTRONICS, LTD.
Download from Www.Somanuals.com. All Manuals Search And Download.
Flash Memory Upgrade
5. Click OK and press the keyboard shortcut key F3 (or select the
“Communication / RS232” command from the Settings menu, or press the
keys: Alt SCR).
The “RS232” window appears. Change the COM port:
Figure 11: RS-232 Window
6. Click Connect.
In the “Atmel – Flip” window, in the Operations Flow column, the Run
button is active, and the name of the chip appears as the name of the third
column: AT89C51RD2.
Verify that in the Buffer Information column, the “HEX File: FC1ETHN.hex”
appears.
FC1ETHN.hex
Figure 12: Atmel – Flip Window (Connected)
7. Click Run.
After each stage in the operation is completed, the check-box for that stage
becomes colored green1.
When the operation is completed, all 4 check-boxes will be colored green and
the status bar message: Memory Verify Pass appears2:
1 See also the blue progress indicator on the status bar
2 If an error message: “Not Finished” shows, click Run again
15
Download from Www.Somanuals.com. All Manuals Search And Download.
Technical Specifications
FC1ETHN.hex
Figure 13: Atmel – Flip Window (Operation Completed)
8. Close the “Atmel – Flip” window.
9. Disconnect the power on the FC-1ETHN.
10. Disconnect the RS-232 port on the FC-1ETHN from the Null-modem
adapter.
11. Set DIP 1 REPROG to OFF.
12. Reconnect the power on the FC-1ETHN.
9
Technical Specifications
Table 6 includes the technical specifications:
Table 6: Technical Specifications1 of the FC-1ETHN Ethernet Controller
ETHERNET INTERFACE:
SERIAL INTERFACES:
10/100 BaseT Ethernet
RS-232, DB9M, signals: RX, TX, RTS, CTS, Ground
RS-485
NETWORK PROTOCOLS:
POWER SOURCE:
DIMENSIONS:
ICMP (ping), ARP, TCP, UDP
12 VDC, <80mA
12cm x 7.5cm x 2.5cm (4.7" x 2.95" x 0.98"), W, D, H
0.3 kg. (0.66 lbs.) approx.
WEIGHT:
ACCESSORIES:
Power supply, mounting bracket
1 Specifications are subject to change without notice
16
KRAMER ELECTRONICS, LTD.
Download from Www.Somanuals.com. All Manuals Search And Download.
LIMITED WARRANTY
Kramer Electronics (hereafter Kramer) warrants this product free from defects in material and workmanship under the
following terms.
HOW LONG IS THE WARRANTY
Labor and parts are warranted for three years from the date of the first customer purchase.
WHO IS PROTECTED?
Only the first purchase customer may enforce this warranty.
WHAT IS COVERED AND WHAT IS NOT COVERED
Except as below, this warranty covers all defects in material or workmanship in this product. The following are not covered
by the warranty:
1.
Any product which is not distributed by Kramer, or which is not purchased from an authorized Kramer dealer. If you are
uncertain as to whether dealer is authorized, please contact Kramer at one of the agents listed in the web site
a
2.
3.
Any product, on which the serial number has been defaced, modified or removed.
Damage, deterioration or malfunction resulting from:
i)
ii)
iii)
iv)
v)
Accident, misuse, abuse, neglect, fire, water, lightning or other acts of nature
Product modification, or failure to follow instructions supplied with the product
Repair or attempted repair by anyone not authorized by Kramer
Any shipment of the product (claims must be presented to the carrier)
Removal or installation of the product
vi)
vii)
Any other cause, which does not relate to a product defect
Cartons, equipment enclosures, cables or accessories used in conjunction with the product
WHAT WE WILL PAY FOR AND WHAT WE WILL NOT PAY FOR
We will pay labor and material expenses for covered items. We will not pay for the following:
1.
2.
Removal or installations charges.
Costs of initial technical adjustments (set-up), including adjustment of user controls or programming. These costs are the
responsibility of the Kramer dealer from whom the product was purchased.
3.
Shipping charges.
HOW YOU CAN GET WARRANTY SERVICE
1.
2.
To obtain service on you product, you must take or ship it prepaid to any authorized Kramer service center.
Whenever warranty service is required, the original dated invoice (or a copy) must be presented as proof of warranty coverage,
and should be included in any shipment of the product. Please also include in any mailing a contact name, company, address, and
a description of the problem(s).
3.
For the name of the nearest Kramer authorized service center, consult your authorized dealer.
LIMITATION OF IMPLIED WARRANTIES
All implied warranties, including warranties of merchantability and fitness for a particular purpose, are limited in duration to
the length of this warranty.
EXCLUSION OF DAMAGES
The liability of Kramer for any effective products is limited to the repair or replacement of the product at our option. Kramer
shall not be liable for:
1.
Damage to other property caused by defects in this product, damages based upon inconvenience, loss of use of the product, loss
of time, commercial loss; or:
2.
Any other damages, whether incidental, consequential or otherwise. Some countries may not allow limitations on how long an
implied warranty lasts and/or do not allow the exclusion or limitation of incidental or consequential damages, so the above
limitations and exclusions may not apply to you.
This warranty gives you specific legal rights, and you may also have other rights, which vary from place to place.
NOTE: All products returned to Kramer for service must have prior approval. This may be obtained from your dealer.
This equipment has been tested to determine compliance with the requirements of:
EN-50081:
"Electromagnetic compatibility (EMC);
generic emission standard.
Part 1: Residential, commercial and light industry"
"Electromagnetic compatibility (EMC) generic immunity standard.
Part 1: Residential, commercial and light industry environment".
FCC Rules and Regulations:
EN-50082:
CFR-47:
Part 15: “Radio frequency devices
Subpart B – Unintentional radiators”
CAUTION!
⌦
Servicing the machines can only be done by an authorized Kramer technician. Any user who makes changes or modifications to
the unit without the expressed approval of the manufacturer will void user authority to operate the equipment.
Use the supplied DC power supply to feed power to the machine.
⌦
⌦
Please use recommended interconnection cables to connect the machine to other components.
17
Download from Www.Somanuals.com. All Manuals Search And Download.
Download from Www.Somanuals.com. All Manuals Search And Download.
For the latest information on our products and a list of Kramer
Updates to this user manual may be found at
We welcome your questions, comments and feedback.
Kramer Electronics, Ltd.
3 Am VeOlamo Street. Jerusalem 95463, Israel Tel: (+972-2)-654-4000
Fax: (+972-2)-653-5369, E-mail: [email protected]
P/N: 2900-104020 REV 1