Kramer Electronics Switch FC 1ETHN User Manual

Kramer Electronics, Ltd.  
USER MANUAL  
Model:  
FC-1ETHN  
Ethernet Controller  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Contents  
Tables  
Table 1: Terminology Used in this User Manual  
2
3
6
Table 2: Features and Functions of the FC-1ETHN Ethernet Controller  
Table 3: FC-1ETHN Configuration Manager Window Functionality  
Table 4: Crossover Cable RJ-45 PINOUT  
8
Table 5: Straight-through Cable RJ-45 PINOUT  
8
Table 6: Technical Specifications of the FC-1ETHN Ethernet Controller  
16  
ii  
KRAMER ELECTRONICS, LTD.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ADDENDUM: FC-1ETHN  
This addendum describes an upgrade to the FC-1ETHN: the Virtual Serial Port.  
Amendment to Section 3  
The following text on page 2 is deleted:  
ñ
Is compatible with the latest Kramer K-Router Windows®-based control  
software (version 4.0 or higher) whose user-friendly interface now allows  
Kramer switchers to be controlled via Ethernet  
The following text is inserted immediately prior to section 3.1:  
The FC-1ETHN now includes the Virtual Serial Port Driver for compatibility  
with applications based on COM-port communication. The Virtual Serial Port:  
ñ
Makes the FC-1ETHN compatible with all Windows®-based  
applications which work through an actual COM port. This includes all versions  
of K-Router and other Kramer control applications. It lets you operate all RS-232  
and RS-485 controllable devices via Ethernet LAN using their existing PC  
software  
ñ
Operates like an actual hardware port, that is, a logical COM that behaves  
like a standard hardware COM but in reality transparently reroutes the data using  
the TCP/IP network to the FC-1ETHN interface via a Virtual Null-modem  
connection, which you can emulate over the Ethernet or Internet  
ñ
Can be created in any quantity on your PC and does not occupy an actual  
serial port  
Amendment to Section 5  
In Table 3: “FC-1ETHN Configuration Manager Window Functionality” (on page 6),  
item 6 is replaced as follows:  
6
Serial Setting In the serial setting speed list, click the appropriate baud speed1 (1200, 2400, 4800, 9600,  
19200, 38400, 57600).  
Note: the FC-1ETHN does not support 115200 baud rate.  
Amendment to Section 6  
The following new section, section 6.4 “Configuring the FC-1ETHN via its Virtual Port”,  
is inserted immediately prior to section 7:  
To configure the FC-1ETHN via the Virtual Port, do the following:  
ñ
Download the Virtual Serial Port Driver at this URL:  
instructions:  
1 The configuration baud is factory preset, and fixed, at 9600  
P/N: 2900 – 1040202  
A1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ADDENDUM: FC-1ETHN  
Figure A1: Virtual Serial Port Manager  
Amendment to Section 7  
Figure A2: Virtual Serial Port Properties  
In section 7.1 (on page 11) steps 5, 6, and 7 are replaced by the following:  
5. Connect the ETHERNET port of your FC-1ETHN to a LAN, using a  
straight-through cable with RJ-45 connectors.  
You can control from up to three computers (each with the Kramer  
Windows®-control software).  
6. Run the Kramer Windows®-control software to control the Kramer  
machine from each computer.  
When working with a non-Kramer device, use their existing PC software  
or the Microsoft HyperTerminal.  
7. In the K-Router Port window, choose the COM port according to the  
number of your virtual Serial port:  
In section 7.1 (on page 11) Figure 6 is replaced by the following:  
Figure A3: Choosing the COM Port  
KRAMER: SIMPLE CREATIVE TECHNOLOGY  
A2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ADDENDUM (this data is included at the end of the Overview section)  
This addendum adds the following information to the user manual:  
Caution – No operator-serviceable parts inside unit.  
Warning – Use only the Kramer Electronics input power  
wall adapter that is provided with this unit1.  
Warning – Disconnect power and unplug unit from wall  
before installing or removing device or servicing unit.  
1 For example: model number AD2512C, part number 2535-000251  
2900-9999992  
A1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ADDENDUM: Ethernet Cross Cable Wiring Connection  
This addendum describes the correct wiring for crossover cable connections  
and replaces the opening paragraph in the "Connecting the ETHERNET Port  
directly to a PC (Crossover Cable)" section in the User Manual as follows:  
Connecting the ETHERNET Port directly to a PC (Crossover Cable)  
You can connect the Ethernet port of the machine to the Ethernet port on your  
PC, via a crossover cable with RJ-45 connectors.  
Table 1 and Figure 1 define the color codes for the two existing standard types  
of cross cables used in the industry. Table 2 defines how to connect the wires  
to the connectors on both ends of the cable.  
When manually connecting the ends of a cable, both connectors must follow  
the same standard (either EIA /TIA 568A or EIA /TIA 568B).  
Table 1: Crossover Cable RJ-45 Types  
1
8
EIA /TIA 568B  
EIA /TIA 568A  
Wire Color  
White-green  
Green  
PIN Wire Color  
PIN  
1
1
2
3
4
5
6
7
8
White-orange  
Orange  
TOP  
2
White-green  
Blue  
3
White-orange  
Blue  
4
White-blue  
Green  
5
White-blue  
Orange  
6
FRONT  
White-brown  
Brown  
7
White-brown  
Brown  
8
1
8
Figure 1: RJ-45 PINOUT  
Table 2: Wiring between Connector One and Two of the Cable  
Signal Pairs  
PINs on  
Connector One  
PINs on Connector  
Two  
Signal Pairs  
TX_D1+  
TX_D1-  
RX_D2+  
RX_D2-  
BI_D3+  
BI_D3-  
1
2
3
6
4
5
7
8
3
6
1
2
7
8
4
5
RX_D2+  
RX_D2-  
TX_D1+  
TX_D1-  
BI_D4+  
BI_D4-  
BI_D4+  
BI_D4-  
BI_D3+  
BI_D3-  
P/N: 2900 - 9999993  
Download from Www.Somanuals.com. All Manuals Search And Download.  
A1  
Introduction  
1
Introduction  
Dedication by Kramer Electronics since 1981, to the development and  
manufacture of high quality video/audio equipment, makes the Kramer line  
an integral part of the finest production and presentation facilities in the  
world. In recent years, Kramer has redesigned and upgraded most of the line,  
making the best even better! The Kramer line of professional video/audio  
electronics is one of the most versatile and complete available, and is a true  
leader in terms of quality, workmanship, price/performance ratio and  
innovation. In addition to the FC-1ETHN Ethernet Controller, we also offer  
excellent switchers and matrices, distribution amplifiers, presentation  
processors, interfaces, remote controllers and computer-related products.  
Congratulations on purchasing your Kramer TOOLS FC-1ETHN Ethernet  
Controller, which is ideal for use with Ethernet / RS-232 interface and  
Ethernet / RS-485 interface. The package includes the following items:  
FC-1ETHN Ethernet Controller  
Power adapter (12V DC Input)  
Windows®-based control software, and Configuration Manager software  
Null-modem adapter  
This user manual1 and the Kramer concise product catalog/CD  
2
3
Getting Started  
We recommend that you:  
Unpack the equipment carefully and save the original box and packaging  
materials for possible future shipment  
Review the contents of this user manual  
Use Kramer high performance high resolution cables2  
Overview  
The high performance FC-1ETHN Ethernet Controller—an upgrade on the  
FC-1ETH—is an easy-to-use, compact, bi-directional hardware and software  
interface system for controlling most Kramer RS-232 and/or RS-485  
controllable machines via Ethernet LAN, as well as via the Internet.  
in the Products section)  
1
Download from Www.Somanuals.com. All Manuals Search And Download.  
Overview  
In particular, the FC-1ETHN:  
Offers network connectivity that lets you connect a Kramer (or other)  
device via its RS-232 or RS-485 port to the Ethernet LAN network  
Lets you control an RS-232 / RS-485 device via Ethernet, from a PC (set  
to Slave routing mode) or other protocol compatible remote controller1  
Lets you control a device from up to three Ethernet points (PCs or remote  
controllers)  
Includes Windows®-based Configuration Management software for serial  
and network programming (including routing mode settings, network settings,  
serial settings, and destination device settings)  
Is compatible with the latest Kramer K-Router Windows®-based control  
software (version 4.0 or higher) whose user-friendly interface now allows  
Kramer switchers to be controlled via Ethernet  
Supports easy dial-up and Internet system remote control (requiring only  
a dedicated IP address and a modem in the remote location) whether it is a  
standalone PC or a LAN system  
Supports using wireless, 802.11b standard based LAN systems for control  
Has capability to facilitate a built-in Web page server  
3.1 Terminology Used in this User Manual  
Table 1 defines some terms that are used in this user manual:  
Table 1: Terminology Used in this User Manual  
Term  
Definition  
802.3  
The standard specification for ETHERNET that is maintained by the Institute of  
Electrical and Electronics Engineers (IEEE).  
Dynamic Host  
Allows the network administrator to distribute IP addresses from a central point  
Configuration Protocol and automatically send a new IP address when an Ethernet point is plugged  
(DHCP)  
into a different network location.  
Gateway  
A network position serving as an entry to another network. On the Internet, a  
node or stopping point can be either a gateway node or a host (end-point) node.  
IP Address  
A 32-binary digit number that identifies each sender or receiver (within a  
network via a particular server or workstation) of data (HTML pages or e-mails)  
that is sent in packets across the Internet.  
Local Area Network  
(LAN)  
Computers sharing a common communications line or wireless link, which often  
share a server within a defined geographic area.  
Media Access Control A computer's unique hardware number in a LAN or other network. On an  
(MAC) Address Ethernet LAN, the (MAC) address is identical to the Ethernet address.  
Transmission Control The basic communication language or protocol of the Internet that breaks the  
Protocol/Internet  
Protocol (TCP/IP)  
message into appropriately sized packets for the network, and can be used as a  
communications protocol in an intranet or an extranet.  
1 When using two FC-1ETHN units, both set to Master routing mode  
2
KRAMER ELECTRONICS, LTD.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Your FC-1ETHN Ethernet Controller  
3.2 Achieving the Best Performance  
Achieving the best performance means:  
Connecting only good quality connection cables, thus avoiding  
interference, deterioration in signal quality due to poor matching, and elevated  
noise levels (often associated with low quality cables)  
Avoiding interference from neighboring electrical appliances and  
positioning your FC-1ETHN away from moisture, excessive sunlight and dust  
4 Your FC-1ETHN Ethernet Controller  
Figure 1 and Table 2 define the FC-1ETHN Ethernet Controller:  
Figure 1: FC-1ETHN Ethernet Controller  
Table 2: Features and Functions of the FC-1ETHN Ethernet Controller  
#
1
2
3
Feature  
Function  
12V DC  
+12V DC connector for powering the unit  
Connects to your LAN  
ETHERNET port  
4
3
2
1
CONFIG  
485 TERM  
RESET  
Used to configure the system  
Used to terminate the RS-485 line  
Used to reset the unit  
REPROG  
Used to upgrade the firmware  
Connects to the RS-232 DB 9 port on a Kramer (or other) device or PC  
4
5
RS-232 port  
A B G (RS-485) port  
Connects to the RS-485 port on a Kramer (or other) device  
PIN A connects to the “A” (+) PIN; PIN B connects to the “B” (–) PIN; and  
PIN G connects to the “G (Ground)” PIN  
6
7
8
9
ON LED  
Illuminates when receiving power  
Lights when the speed is 100M  
Lights when the speed is 10M  
100M LED  
10M LED  
STATUS LED  
Ready for communication if one STATUS LED flashes; communication  
already exists if both STATUS LEDs flash  
10 STATUS LED  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
Using the Kramer Configuration Manager Software  
5 Using the Kramer Configuration Manager Software  
This section describes:  
How to install and run the Configuration Manager software, see section 5.1  
The Configuration Manager Window features, see section 5.2  
5.1 Installing and Running the Kramer Configuration Manager Software  
To install the Kramer Configuration Manager software:  
Insert the CD-ROM in the CD-ROM drive, double click the Setup.exe file  
and follow the on-screen instructions  
To run the Kramer Configuration Manager software (for the first time):  
1. Click the appropriate shortcut in the Start menu’s Programs folder.  
The Choose Port window appears as follows:  
Figure 2: Choose Port Window  
2. Choose the LAN port for configuration via Ethernet, or the appropriate  
COM port for configuration via serial cable (see section 6.1) and click OK.  
The FC-1ETHN Configuration Manager window (see Figure 3) opens.  
To run the Kramer Configuration Manager software (subsequently):  
Click the appropriate shortcut in the Start menu’s Programs folder.  
The FC-1ETHN Configuration Manager window (see Figure 3) opens  
5.2 Understanding the Kramer Configuration Manager Window  
Figure 3 and Table 3 define the FC-1ETHN Configuration Manager window:  
4
KRAMER ELECTRONICS, LTD.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Using the Kramer Configuration Manager Software  
Figure 3: FC-1ETHN Configuration Manager Window  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
Using the Kramer Configuration Manager Software  
Table 3: FC-1ETHN Configuration Manager Window Functionality  
#
Feature  
Device List  
Function  
1
Displays the MAC Addresses for the FC-1ETHN devices, connected via the selected  
port (LAN or COM).  
2
3
Master Mode When selected, activates the Master mode (see section 6.3.2).  
Check Box  
DHCP1  
When cleared, activates the Slave mode (see section 6.3.1).  
When selected, automatically configures the FC-1ETHN to obtain an IP address from  
Mode Check the network administrator via the Dynamic Host Configuration Protocol (DHCP)  
Box  
When cleared, manual configuration of the FC-1ETHN is required to obtain an IP  
address (Static IP)  
4
Network  
Settings  
IP Address: A 32-binary digit number obtained  
from your Network Administrator that identifies the  
FC-1ETHN device that is currently being  
configured in the Ethernet or Internet.  
For example:  
Subnet: A 32-binary digit number obtained from  
your Network Administrator, which combined with  
the IP Address, identifies which network your  
FC-1ETHN device is on.  
Gateway: A network position serving as an entry  
to another network or to the Internet (only relevant  
in the Master Routing mode).  
Local Port is an address of the FC-1ETHN device  
that is currently being configured that provides a  
direct route from another Ethernet point application.  
5
Destination Destin. IP A 32-binary digit number that identifies For example:  
Device  
Settings  
the destination FC-1ETHN device in the Ethernet  
or Internet.  
Port is a pre-assigned address of the destination  
FC-1ETHN device that provides a direct route to  
its Transport layer.  
6
7
Serial  
Setting  
In the serial setting speed list, click the appropriate baud speed2 (1200, 2400, 4800,  
9600, 19200, 38400, 57600, 115200).  
Action  
Search: seeks the FC-1ETHN devices that connect to the PC via the chosen LAN or  
Buttons  
COM port, and displays them and their corresponding settings.  
Setting: adjusts the FC-1ETHN according to the displayed data.  
8
9
Progress Bar Shows the progress  
Status Bar  
Shows the status  
10 Exit Button  
11 Version  
Closes the Configuration Manager application  
Displays the firmware version number  
12 Menu bar  
File menu’s Exit command closes the Configuration Manager application.  
Action menu’s Search Board command seeks the FC-1ETHN devices that connect to  
the PC via the chosen LAN or COM port, and displays them and their corresponding  
settings.  
Action menu’s Setting command adjusts the FC-1ETHN according to the displayed  
data.  
Port menu displays the Choose Port window.  
Set MAC1 menu is for factory use only (click the Password command to enter the  
password).  
1 See definition in Table 1  
2 The configuration baud is factory preset, and fixed, at 9600  
6
KRAMER ELECTRONICS, LTD.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Configuring the FC-1ETHN Ethernet Controller  
6 Configuring the FC-1ETHN Ethernet Controller  
This section describes how to configure the FC-1ETHN via its:  
Serial1 port, see section 6.1  
ETHERNET1 port, see section 6.2  
6.1 Configuring the FC-1ETHN via its Serial Port  
You can configure the FC-1ETHN via its RS-232 port.  
To configure the FC-1ETHN via RS-232, do the following:  
1. Set the CONFIG DIP2 (DIP 4) to ON.  
Leave the other three DIPs3 set to OFF.  
2. Connect the RS-232 port of the FC-1ETHN to the Null-modem adapter  
and connect the Null-modem adapter with a 9 wire flat cable to the  
RS-232 DB9 COM port on your PC.  
3. Run the Kramer Configuration Manager software (see section 5.1) and  
choose the COM port that is appropriate for your computer from the  
FC-1ETHN Configuration Manager window (see section 5.2).  
4. Click the Search button (or the Action menu’s, Search Board command).  
The MAC Address for the found “FC-1ETHN” appears in the Device List.  
5. Change the settings and then click the Setting button (or the Action  
menu’s, Setting command) to apply the settings.  
Note: be aware that this will alter the IP settings in the FC-1ETHN.  
6. Set the CONFIG DIP2 (DIP 4) to OFF.  
Leave the other three DIPs3 set to OFF.  
7. Disconnect the power to the FC-1ETHN, and then reconnect it.  
1 The serial mode is always available even if the FC-1ETHN is not correctly setup, whereas the Ethernet mode is not a  
separate mode and can proceed in parallel with the normal operation of the FC-1ETHN  
2 See item 3 in Table 2  
3 485 TERM (DIP 3), RESET (DIP 2), and REPROG (DIP 1)  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
Configuring the FC-1ETHN Ethernet Controller  
6.2 Configuring the FC-1ETHN via its ETHERNET port  
You can configure the FC-1ETHN via its ETHERNET port.  
To configure the FC-1ETHN via ETHERNET, do the following:  
1. Connect the ETHERNET port of the FC-1ETHN to the LAN port on  
your PC, via a crossover cable with RJ-45 connectors, as Table 4 defines:  
Table 4: Crossover Cable RJ-45 PINOUT  
Side 1  
Side 2  
PIN Wire Color  
PIN Wire Color  
1
2
3
4
5
6
7
8
White-orange  
Orange  
1
2
3
4
5
6
7
8
White-green  
Green  
White-green  
Blue  
White-orange  
Blue  
White-blue  
Green  
White-blue  
Orange  
White-brown  
Brown  
White-brown  
Brown  
If connecting the ETHERNET port of the FC-1ETHN to the LAN port on  
a network hub or network router, use a straight-through cable with RJ-45  
connectors, as Table 5 defines:  
Table 5: Straight-through Cable RJ-45 PINOUT  
Side 1  
Side 2  
PIN Wire Color  
PIN Wire Color  
1
2
3
4
5
6
7
8
White-orange  
Orange  
1
2
3
4
5
6
7
8
White-orange  
Orange  
White-green  
Blue  
White-green  
Blue  
White-blue  
Green  
White-blue  
Green  
White-brown  
Brown  
White-brown  
Brown  
2. Run the Kramer Configuration Manager software (see section 5.1) and  
choose the LAN port (see Figure 2).  
3. Click the Search button (or the Action menu’s, Search Board command).  
The MAC Address for the found “FC-1ETHN” appears in the Device List.  
4. Change the settings and then click the Setting button (or the Action  
menu’s, Setting command) to apply the settings.  
Note: be aware that this will alter the IP settings in the FC-1ETHN.  
8
KRAMER ELECTRONICS, LTD.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Configuring the FC-1ETHN Ethernet Controller  
6.3 Routing Data in the Slave and Master Routing Modes  
The FC-1ETHN routes data in either the Slave Routing Mode (see section  
6.3.1) or the Master Routing Mode (see section 6.3.2).  
6.3.1  
Slave Routing Mode  
In the Slave Routing Mode, the FC-1ETHN never sends any data in the serial  
port-Ethernet direction before it first receives some data from the remote  
station (that is, the data in the Ethernet-serial direction). Serial data that is  
received at the serial port of the FC-1ETHN before the remote station  
contacts the FC-1ETHN is discarded. In the Slave Mode, the FC-1ETHN  
will work with any station on the network that contacts it (but not more than  
three stations simultaneously), as the example in Figure 4 illustrates:  
Figure 4: Connecting the FC-1ETHN in the Slave Routing Mode  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
Controlling Kramer Machines via Ethernet using the FC-1ETHN  
6.3.2  
Master Routing Mode  
In the Master Routing Mode, the FC-1ETHN does not wait for the remote  
station to send the data first, and routes the data in the destination device  
direction as soon as there is data to be sent. The data is always sent to a  
specific destination (as defined by the Destination IP address and Destination  
Data Port Number Settings of the FC-1ETHN). Also, the FC-1ETHN only  
accepts the data sent from the remote station whose IP address matches the  
one set in the Destination IP address. The FC-1ETHN will discard the data  
sent from any other IP. See the example illustrated in Figure 5:  
Figure 5: Connecting the FC-1ETHN in the Master Routing Mode  
7
Controlling Kramer Machines via Ethernet using the FC-1ETHN  
You can use your FC-1ETHN to control a Kramer machine from computers  
that connect to a LAN1 (see section 7.1) or via a controller1 (see section 7.2).  
1 As well as via an Internet connection  
10  
KRAMER ELECTRONICS, LTD.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Controlling Kramer Machines via Ethernet using the FC-1ETHN  
7.1 Controlling a Kramer Machine via a Computer  
To control a Kramer machine via three computers, as the example in Figure 4  
illustrates, do the following:  
1. Configure the FC-1ETHN to the Slave Routing Mode (see section 6).  
2. Set all the DIPs to OFF.  
3. Connect the 12V DC power adapter to the power socket and connect the  
adapter to the mains electricity.  
4. Connect the RS-232 port of your Kramer machine to the RS-232 port of  
the FC-1ETHN via a Null modem (alternatively, connect the RS-485 port  
of your Kramer machine to the ABG port1 of the FC-1ETHN).  
5. Connect the ETHERNET port of your FC-1ETHN to a LAN, using a  
straight-through cable with RJ-45 connectors.  
You can control from up to three computers (each with the Kramer  
K-Router Windows®-control software (version 4.0 or higher)).  
6. Run the Kramer K-Router Windows®-control software (version 4.0 or  
higher) to control the Kramer machine from each computer.  
Use the Microsoft HyperTerminal if working with a non-Kramer device.  
7. In the K-Router Port window, click the Remote Connection option and set  
the RemoteHost and RemotePort, as per the FC-1ETHN configuration:  
Figure 6: Connecting the FC-1ETHN in the Master Routing Mode  
1 Connect PIN A to the “A” (+) PIN, PIN B to the “B” (–) PIN, and PIN G to the “G (Ground)” PIN  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Flash Memory Upgrade  
7.2 Controlling a Kramer Machine via a Controller  
To control a Kramer machine via two VS-3000 controllers, as the Master  
Mode example in Figure 5 illustrates, do the following:  
1. Configure each FC-1ETHN to the Master Routing Mode (see section 6).  
2. Set all the DIPs to OFF on each FC-1ETHN.  
3. Connect the RS-232 port of your Kramer machine to the RS-232 port of a  
FC-1ETHN via a Null modem (alternatively, connect the RS-485 port of  
your Kramer machine to the ABG port1 of the FC-1ETHN) and connect  
the ETHERNET port of that FC-1ETHN to a LAN.  
4. Connect the ETHERNET port of another FC-1ETHN to the same LAN  
and connect the RS-232 port of the controller to the RS-232 port of that  
FC-1ETHN (alternatively, connect the RS-485 port of the controller to the  
ABG port1 of the FC-1ETHN).  
5. Connect the ETHERNET port of another FC-1ETHN to the same LAN  
and connect the RS-232 port of the controller to the RS-232 port of that  
FC-1ETHN via a Null modem (alternatively, connect the RS-485 port of  
the controller to the ABG port1of the FC-1ETHN).  
6. On each FC-1ETHN, connect the 12V DC power adapter to the power  
socket and connect the adapter to the mains electricity.  
8
Flash Memory Upgrade  
The FC-1ETHN firmware is located in FLASH memory, which lets you  
upgrade to the latest Kramer firmware version in minutes! The process  
involves:  
Downloading from the Internet (see section 8.1)  
Connecting the PC to the RS-232 port (see section 8.2)  
Upgrading Firmware (see section 8.3)  
8.1 Downloading from the Internet  
You can download the up-to-date file from the Internet. To do so:  
the file: “FLIP_ FC1ETHN.zip” from the Technical Support section.  
2. Extract the file: “FLIP_ FC1ETHN.zip” to a folder (for example,  
1 Connect PIN A to the “A” (+) PIN, PIN B to the “B” (–) PIN, and PIN G to the “G (Ground)” PIN  
12  
KRAMER ELECTRONICS, LTD.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Flash Memory Upgrade  
C:\Program Files\Kramer Flash).  
3. Create a shortcut on your desktop to the file: “FLIP.EXE”.  
8.2 Connecting the PC to the RS-232 Port  
Before installing the latest Kramer firmware version on a FC-1ETHN unit,  
do the following:  
1. Connect the RS-232 DB9 port on the FC-1ETHN to the Null-modem  
adapter and connect the Null-modem adapter with a 9 wire flat cable to the  
RS-232 DB9 COM port on your PC.  
It is recommended that you use COM port1 2. However, if your computer has  
only one COM port, open the file: “FC1ETHN.cfg” (located at C:\Program  
Files\Kramer Flash\ FC1ETHN.cfg) in Notepad, and change “set port  
COM2” to “set port COM1”.  
2. Connect the power on the FC-1ETHN unit.  
3. Set the DIP 1 REPROG to ON.  
8.3 Upgrading Firmware  
Follow these steps to upgrade the firmware:  
1. Double click the desktop icon: “Shortcut to FLIP.EXE”.  
The Splash screen appears as follows:  
Figure 7: Splash Screen  
2. After a few seconds, the Splash screen is replaced by the “Atmel – Flip”  
window:  
1 The software is preset for use with COM port 2  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Flash Memory Upgrade  
Figure 8: Atmel – Flip Window  
3. Press the keyboard shortcut key F4 (or select the “Read Configuration  
File” command from the File menu, or press the keys: Alt FR).  
The “Open Configuration File” window appears:  
FC1ETHN.CFG  
Figure 9: Open Configuration File Select Window  
4. Choose the file: “FC1ETHN.cfg” (by double-clicking it).  
If COM 2 was not selected (see section 8.2), an RS-232 error message  
appears. In the “Atmel – Flip” window, the Operations Flow column is  
disabled, and crosses appear in the third column.  
Figure 10: Atmel – Flip Window (RS-232 Communication)  
14  
KRAMER ELECTRONICS, LTD.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Flash Memory Upgrade  
5. Click OK and press the keyboard shortcut key F3 (or select the  
Communication / RS232” command from the Settings menu, or press the  
keys: Alt SCR).  
The “RS232” window appears. Change the COM port:  
Figure 11: RS-232 Window  
6. Click Connect.  
In the “Atmel – Flip” window, in the Operations Flow column, the Run  
button is active, and the name of the chip appears as the name of the third  
column: AT89C51RD2.  
Verify that in the Buffer Information column, the “HEX File: FC1ETHN.hex”  
appears.  
FC1ETHN.hex  
Figure 12: Atmel – Flip Window (Connected)  
7. Click Run.  
After each stage in the operation is completed, the check-box for that stage  
becomes colored green1.  
When the operation is completed, all 4 check-boxes will be colored green and  
the status bar message: Memory Verify Pass appears2:  
1 See also the blue progress indicator on the status bar  
2 If an error message: “Not Finished” shows, click Run again  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Technical Specifications  
FC1ETHN.hex  
Figure 13: Atmel – Flip Window (Operation Completed)  
8. Close the “Atmel – Flip” window.  
9. Disconnect the power on the FC-1ETHN.  
10. Disconnect the RS-232 port on the FC-1ETHN from the Null-modem  
adapter.  
11. Set DIP 1 REPROG to OFF.  
12. Reconnect the power on the FC-1ETHN.  
9
Technical Specifications  
Table 6 includes the technical specifications:  
Table 6: Technical Specifications1 of the FC-1ETHN Ethernet Controller  
ETHERNET INTERFACE:  
SERIAL INTERFACES:  
10/100 BaseT Ethernet  
RS-232, DB9M, signals: RX, TX, RTS, CTS, Ground  
RS-485  
NETWORK PROTOCOLS:  
POWER SOURCE:  
DIMENSIONS:  
ICMP (ping), ARP, TCP, UDP  
12 VDC, <80mA  
12cm x 7.5cm x 2.5cm (4.7" x 2.95" x 0.98"), W, D, H  
0.3 kg. (0.66 lbs.) approx.  
WEIGHT:  
ACCESSORIES:  
Power supply, mounting bracket  
1 Specifications are subject to change without notice  
16  
KRAMER ELECTRONICS, LTD.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
LIMITED WARRANTY  
Kramer Electronics (hereafter Kramer) warrants this product free from defects in material and workmanship under the  
following terms.  
HOW LONG IS THE WARRANTY  
Labor and parts are warranted for three years from the date of the first customer purchase.  
WHO IS PROTECTED?  
Only the first purchase customer may enforce this warranty.  
WHAT IS COVERED AND WHAT IS NOT COVERED  
Except as below, this warranty covers all defects in material or workmanship in this product. The following are not covered  
by the warranty:  
1.  
Any product which is not distributed by Kramer, or which is not purchased from an authorized Kramer dealer. If you are  
uncertain as to whether dealer is authorized, please contact Kramer at one of the agents listed in the web site  
a
2.  
3.  
Any product, on which the serial number has been defaced, modified or removed.  
Damage, deterioration or malfunction resulting from:  
i)  
ii)  
iii)  
iv)  
v)  
Accident, misuse, abuse, neglect, fire, water, lightning or other acts of nature  
Product modification, or failure to follow instructions supplied with the product  
Repair or attempted repair by anyone not authorized by Kramer  
Any shipment of the product (claims must be presented to the carrier)  
Removal or installation of the product  
vi)  
vii)  
Any other cause, which does not relate to a product defect  
Cartons, equipment enclosures, cables or accessories used in conjunction with the product  
WHAT WE WILL PAY FOR AND WHAT WE WILL NOT PAY FOR  
We will pay labor and material expenses for covered items. We will not pay for the following:  
1.  
2.  
Removal or installations charges.  
Costs of initial technical adjustments (set-up), including adjustment of user controls or programming. These costs are the  
responsibility of the Kramer dealer from whom the product was purchased.  
3.  
Shipping charges.  
HOW YOU CAN GET WARRANTY SERVICE  
1.  
2.  
To obtain service on you product, you must take or ship it prepaid to any authorized Kramer service center.  
Whenever warranty service is required, the original dated invoice (or a copy) must be presented as proof of warranty coverage,  
and should be included in any shipment of the product. Please also include in any mailing a contact name, company, address, and  
a description of the problem(s).  
3.  
For the name of the nearest Kramer authorized service center, consult your authorized dealer.  
LIMITATION OF IMPLIED WARRANTIES  
All implied warranties, including warranties of merchantability and fitness for a particular purpose, are limited in duration to  
the length of this warranty.  
EXCLUSION OF DAMAGES  
The liability of Kramer for any effective products is limited to the repair or replacement of the product at our option. Kramer  
shall not be liable for:  
1.  
Damage to other property caused by defects in this product, damages based upon inconvenience, loss of use of the product, loss  
of time, commercial loss; or:  
2.  
Any other damages, whether incidental, consequential or otherwise. Some countries may not allow limitations on how long an  
implied warranty lasts and/or do not allow the exclusion or limitation of incidental or consequential damages, so the above  
limitations and exclusions may not apply to you.  
This warranty gives you specific legal rights, and you may also have other rights, which vary from place to place.  
NOTE: All products returned to Kramer for service must have prior approval. This may be obtained from your dealer.  
This equipment has been tested to determine compliance with the requirements of:  
EN-50081:  
"Electromagnetic compatibility (EMC);  
generic emission standard.  
Part 1: Residential, commercial and light industry"  
"Electromagnetic compatibility (EMC) generic immunity standard.  
Part 1: Residential, commercial and light industry environment".  
FCC Rules and Regulations:  
EN-50082:  
CFR-47:  
Part 15: “Radio frequency devices  
Subpart B – Unintentional radiators”  
CAUTION!  
Servicing the machines can only be done by an authorized Kramer technician. Any user who makes changes or modifications to  
the unit without the expressed approval of the manufacturer will void user authority to operate the equipment.  
Use the supplied DC power supply to feed power to the machine.  
Please use recommended interconnection cables to connect the machine to other components.  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
For the latest information on our products and a list of Kramer  
Updates to this user manual may be found at  
We welcome your questions, comments and feedback.  
Kramer Electronics, Ltd.  
3 Am VeOlamo Street. Jerusalem 95463, Israel Tel: (+972-2)-654-4000  
Fax: (+972-2)-653-5369, E-mail: [email protected]  
P/N: 2900-104020 REV 1  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Ingersoll Rand Marine Sanitation System 65875 XC User Manual
JVC CD Player KD DV5101 User Manual
JVC DVD VCR Combo HR XVC15U User Manual
JVC Flat Panel Television EM39T User Manual
Kenmore Vacuum Cleaner 11623637C User Manual
Kenwood Stereo System VRS 7100 User Manual
KitchenAid Dishwasher KUDA230Y User Manual
Kodak Digital Camera V610 User Manual
Kodak DVD Player DVD7000 User Manual
Koss Headphones HB79S User Manual