Kodak Camera Accessories CIS 267E User Manual

CURRENT INFORMATION SUMMARY  
July 2006 CIS-267E  
Using KODAK Chemicals with  
KONICA 8xx series and R1 & R2  
Minilabs  
The processing chemicals that you use in a particular  
minilab system depend on the type of processor the system  
incorporates and its process cycle. This publication  
describes the use of KODAK EKTACOLOR PRIME LORR  
Chemicals to process KODAK EKTACOLOR EDGE and  
ROYAL Digital Color Papers in the KONICA 8xx series  
and R1& R2 Minilabs that are compatible with the  
Konica CPK-2-22 LR (SQA) process designation.  
ORDERING KODAK EKTACOLOR PRIME  
LORR CHEMICALS  
KODAK EKTACOLOR PRIME LORR Chemicals are  
available in convenient mix sizes. The catalog numbers in  
the following Table 1 are for Europe and the Middle East  
Region. The table shows the product details and the number  
of 10.2 x 15.2 cm (4 x 6-inch) prints that can be processed  
per unit (to-make 10 litres).  
Other publications are available on the Kodak website  
at www.Kodak.com/go/photochemicals; select the link for  
“Processing Manuals.” Current versions of Current  
Information Summaries are available at the link for  
“Technical Information.”  
Table 1 Processing Capacities  
10x15cm  
KODAK Chemical  
& make size  
CAT No.  
Prints per 10L  
KODAK  
EKTACOLOR  
PRIME SP  
Developer  
Replenisher LORR  
4x 10L  
RECOMMENDED KODAK CHEMICALS  
527 0996  
5446  
You may use KODAK Chemicals for the KONICA 8xx  
series and related Minilabs, using these instructions. They  
offer convenience, cost savings, and a minimum of solution  
waste. KODAK EKTACOLOR PRIME SP Developer  
Replenisher LORR offers the advantages of a single-part  
concentrate for convenient handling and a low  
replenishment rate. In addition to the developer, you will  
need KODAK EKTACOLOR PRIME SP Bleach-Fix  
Replenisher LORR. You will also need KODAK  
KODAK  
EKTACOLOR  
PRIME SP Bleach-  
Fix Replenisher  
LORR 2x 10L  
528 8105  
527 0863  
8714  
KODAK  
EKTACOLOR  
PRIME Stabilizer  
and Replenisher  
LORR 10x 10L  
EKTACOLOR PRIME Stabilizer and Replenisher LORR.  
1662*  
* This is the capacity for processors with three stabilizer tanks. If  
the processor has four stabilizer tanks, the capacity is  
approximately 3324.  
You will need to mix developer, bleach-fix and  
stabilizer replenisher solutions for these chemicals. The  
processor automatically determines the amount of paper  
processed and delivers the necessary amounts of the  
replenishers to the processor tanks.  
Eastman Kodak Company, 2006  
Download from Www.Somanuals.com. All Manuals Search And Download.  
tanks. When you have reinstalled all the racks and have  
verified that all the tanks are filled with solution, turn on  
the recirculation and heater system and bring the solutions  
up to operating temperature.  
Developer Fresh Tank Solution  
To ensure good performance, take special care in mixing the  
developer tank solution. You should mix the developer  
replenisher in a separate mixing vessel from the one used for  
bleach-fix.  
USING CONTROL STRIPS TO MONITOR THE  
PROCESS  
Preparing Developer Tank Solution from KODAK  
EKTACOLOR PRIME SP Developer Replenisher  
LORR, To prepare 1L.  
Use KODAK Control Strips, Process RA-4 (box of 50,  
CAT No. 8282170), to monitor process performance. For  
instructions on processing control strips, see the operator’s  
manual for the KONICA Minilab. For information on the  
use and diagnostic features of the control strips, see  
KODAK Publication No. Z-130, Using KODAK  
EKTACOLOR Chemicals, Section 7, “Process Monitoring  
and Troubleshooting with KODAK Control Strips, Process  
RA-4.” KODAK Publications are described and available on  
the Kodak website at  
Table 3  
Volume  
EKTACOLOR PRIME SP  
Developer LORR, mixed  
Replenisher*  
670ml  
24mL  
EKTACOLOR RA Developer  
Starter (CAT No 5278957),  
Water  
306mL  
1.0 L  
To calculate control-strip aim values for process  
monitoring, you will need to apply process adjustment  
factors. Use the adjustment factors in addition to the  
correction factors that are supplied with the control strips.  
Total volume  
* Mixed as directed on the product label  
Bleach-Fix Fresh Tank Solution  
Be very careful to avoid contamination of the developer  
with bleach-fix.  
After reading the densities of the supplied reference  
strip on your densitometer, first apply the “Prime”  
correction factors packaged with the reference strip. Then  
add the values from the following table. The corrected  
density values are the aim values for your batch of control  
strips. You will need to apply the adjustment factors each  
time you switch to a new batch of control strips.  
Preparing Bleach-Fix Tank Solution from KODAK  
EKTACOLOR PRIME SP Bleach-Fix Replenisher  
LORR  
Table 4  
Volume  
Table 5. Process Adjustment Factors  
EKTACOLOR PRIME SP Bleach-  
950ml  
Measurement  
Black (BP)  
High (HD)  
Low (LD)  
R
G
B
Fix LORR, mixed Replenisher*  
+0.07  
+0.01  
-0.04  
+0.01  
+0.01  
+0.07  
+0.05  
+0.01  
-0.05  
-0.06  
-0.07  
+0.01  
EKTACOLOR PRIME SP  
Bleach-Fix Starter (CAT No.  
5288139)  
50mL  
1.0 L  
Total volume  
D-min  
* Mixed as directed on the product label  
Stabilizer Fresh Tank Solution  
Mix the working tank solution in each of the stabilizer  
tanks.  
SILVER RECOVERY  
When an effluent tank is full, the processor alerts you to  
drain the tank.  
Typically, silver concentration in the bleach-fix effluent  
tank will be 4 to 8 g/L; silver concentration in the stabilizer  
effluent tank will be 0.2 to 0.6 g/L.  
To prepare one litre of stabilizer tank solution, mix  
EKTACOLOR PRIME Stabilizer and Replenisher LORR  
(as directed on the product label), no further dilution is  
required.  
You can effectively use common silver-recovery  
methods with the combined effluents from both effluent  
tanks. If your lab has other processors, you can combine the  
effluent from the KONICA Minilab with the other effluent  
solutions and use your current silver-recovery methods.  
Publications on silver management that include  
recommendations and descriptions of silver-recovery  
options are available in the Silver Management section of  
the KODAK Product Safety, Recycling & Disposal Center,  
under “Chemicals” at www.Kodak.com/go/KES.  
Reinstalling the Racks and Bringing the Tank  
Solutions to Temperature  
You should allow some space when filling the tanks, to  
allow for the volume of the racks. When you reinstall the  
racks in the tanks, the racks will displace more solution  
volume to fill the tanks.  
Install the racks by slowly lowering them into the  
Using KODAK Chemicals with KONICA 808 and Related Minilabs KODAK Publication No. CIS-267E  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Digital & Film Imaging Systems  
EASTMAN KODAK COMPANY • ROCHESTER, NY 14650  
Using KODAK Chemicals with  
KONICA 8xx series and R1 & R2 Minilabs  
KODAK Publication No. CIS-267E  
Kodak, Edge, Ektacolor, Prime, and Royal  
are trademarks of Eastman Kodak Company.  
New 7-06  
Using KODAK Chemicals with KONICA 808 and Related Minilabs KODAK Publication No. CIS-267E  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Intel Computer Drive 325152002US User Manual
Jacuzzi Indoor Furnishings BK37 User Manual
John Deere Compact Loader 544J WH User Manual
JVC Camcorder LYT2202 001A M User Manual
JVC Microcassette Recorder BR HD50 User Manual
Kambrook Iron KSS70 User Manual
Kenmore Gas Grill 4151613911 User Manual
Kenwood Amplified Phone NX 240V16P User Manual
KitchenAid Dishwasher KUDE60FVBL0 User Manual
Korg Computer Monitor DTR 1000 User Manual