®
®
Pro Line Front-Loading Washer
PRODUCT MODEL NUMBERS
OVERALL DIMENSIONS
KHWV01R
57"
(144.8 cm)
Electrical: To supply the required 3 or 4 wire,
single phase, 120/240 volt 60 Hz, AC only electrical
supply (or 3 or 4 wire, 120/208 volt electrical
supply, if specified on the serial/rating plate) on a
separate 30-amp circuit, fused on both sides of the
line. A time-delay fuse or circuit breaker is
recommended. Connect to an individual branch
circuit. Do not have a fuse in the neutral or
grounding circuit.
42"
(106.7 cm)**
*Includes door handle
**Includes feet extended 1" (2.5 cm)
Exhaust venting: Exhaust your dryer to the
outside. Four inch diameter vent is required. Rigid
or flexible metal exhaust vent must be used. Do not
use plastic or metal foil vent. Exhaust outlet hood
must be at least 12 inches from the ground or any
object that may be in the path of the exhaust.
33" (83.8 cm)*
27"
(68.6 cm)
DRAIN SYSTEMS OPTIONS
RECESSED AREA AND CLOSET INSTALLATION WITH OR WITHOUT PEDESTAL
For closet installation, with a door, the minimum ventilation openings in the top and
bottom of the door are required. Louvered doors with equivalent air ventilation openings
in the top and bottom are acceptable.
Standpipe drain system – wall or floor (view A & B)
The standpipe drain requires aminimum diameter
standpipe of 2" (5 cm). The minimum carry-away can
be no less than 17 gal. (64 L) per minute.
The top of the standpipe must be at least 30" (76.2
cm) high and no higher than 96" (244 cm) from the
bottom of the washer.
3"
(7.6 cm)
48 in.2
(310 cm 2 )*
24 in.2
(155 cm 2 )*
3"
(7.6 cm)
30" min.
(76.2 cm)
1"
(2.5 cm)
27"
(68.6 cm)
1"
(2.5 cm
33"
4"
1"
(2.5 cm)
)
(83.8 cm) (10.2 cm)
C
A
B
A. Recessed area
B. Side view - closet or confined area
C. Closet door with vents
A
B
7" (17,8 cm)*
7" (17,8 cm)*
*Required spacing
Laundry tub drain system (view A)
The laundry tub needs a minimum 20 gal. (76 L)
capacity. The top of the laundry tub must be at least
30" (76.2 cm) above the floor.
Floor tub drain system (view B)
The floor drain system requires a siphon break that
may be purchased separately.
The siphon break must be a minimum of 28" (71 cm)
from the bottom of the washer. Additional hoses
might be needed.
Recommended installation
spacing for cabinet installation
For cabinet installation, with a door,
the minimum ventilation openings in
the top are required.
1"
27"
1"
1"
4"
33"
(83,8 cm)
(2,5 cm) (68,6 cm) (2,5 cm) (2,5 cm)
(10,2 cm)
B
A
C
A.Front view
B. Side view
28" min.
(71 cm)
30" min.
(76.2 cm)
C. Cabinet with vents
C
D
Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.
Ref. 3957648
06-27-06
Download from Www.Somanuals.com. All Manuals Search And Download.
|