30" (76.2 cm) and 36" (91.4 cm) Wall-Mount Canopy Range Hood
PRODUCT DIMENSIONS
PRODUCT MODEL NUMBERS
KXW4330Y KXW4336Y
Electrical Requirements:
10¾" (27.3 cm)
3³⁄₈" (8.6 cm)
5⁷⁄₈" (15.0 cm)
ꢀ
A 120 volt, 60 Hz., AC only, 15-amp, fused electrical circuit is
13³⁄₁₆" (33.5 cm)
required.
ꢀ
If the house has aluminum wiring, follow the procedure below:
1. Connect a section of solid copper wire to the pigtail
leads.
*28⁵⁄₁₆" (71.9 cm) min.
42⁵⁄₈" (108.3 cm) max.
2. Connect the aluminum wiring to the added section
of copper wire using special connectors and/or
tools designed and UL listed for joining copper to
aluminum.
Follow the electrical connector manufacturer's recommended
procedure. Aluminum/copper connection must conform with local
codes and industry accepted wiring practices.
24"
(60.8 cm)
17¹¹⁄₁₆"
(45 cm)
**24⁵⁄₈" (62.5 cm) min.
38¾" (98.4 cm) max.
CABINET OPENING DIMENSIONS
30" (76.2 cm)
36" (91.4 cm)
5"
(12.7 cm)
10" (25.4 cm) min.
13" (33.0 cm) max.
2" (5.1 cm) min.
19¹¹⁄₁₆" (50.0 cm)
9" (22.9 cm) min.*
9¹⁄₂" (24.1 cm)
*For non-vented (recirculating) installation
**For vented installations
VENTING REQUIREMENTS
ꢀ
Vent system must terminate to the outdoors, except for non-vented
(recirculating) installations.
Vent and power
10" (25.4 cm) min.
supply cable
13" (33.0 cm) max.
entry location
ꢀ
Do not terminate the vent system in an attic or other enclosed area.
ꢀ
Do not use 4" (10.2 cm) laundry-type wall cap.
ꢀ
17" (43.2 cm)*
Use metal vent only. Rigid metal vent is recommended. Plastic or metal foil
vent is not recommended.
ꢀ
Side
The length of vent system and number of elbows should be kept to a
minimum to provide efficient performance.
Side
cabinet
cabinet
30" (76.2 cm) or
36" (91.4 cm)
For the most efficient and quiet operation:
ꢀ
"X"
Use no more than three 90° elbows.
bottom of
canopy
ꢀ
Make sure there is a minimum of 24" (61.0 cm) of straight vent between the
elbows if more than 1 elbow is used.
to cooking
surface
Centerline
Cooking surface
ꢀ
Do not install 2 elbows together.
ꢀ
Use clamps to seal all joints in the vent system.
*For non-vented (recirculating) installations
ꢀ
The vent system must have a damper. If the roof or wall cap has a damper, do
not use the damper supplied with the range hood.
IMPORTANT:
Minimum distance “X”: 24" (61.0 cm) from electric
cooking surface.
ꢀ
Use caulking to seal exterior wall or roof opening around the cap.
ꢀ
The size of the vent should be uniform.
Minimum distance “X”: 27" (68.6 cm) from gas
cooking surfaces.
Cold Weather Installations
Suggested maximum distance “X”: 36" (91.4 cm)
An additional back draft damper should be installed to minimize backward cold
air flow and a thermal break should be installed to minimize conduction of
outside temperatures as part of the vent system. The damper should be on the
cold air side of the thermal break.
The chimneys can be adjusted for different ceiling heights. See the
following chart.
Vented Installations
The break should be as close as possible to where the vent system enters the
heated portion of the house.
Min. ceiling height Max. ceiling height
Electric cooking surface
Gas cooking surface
7' 1" (2.16 m)
7' 4" (2.23 m)
9' 2" (2.79 m)
9' 2" (2.79 m)
Makeup Air
Local building codes may require the use of make up air systems when using
ventilation systems greater than specified CFM of air movement. The specified
CFM varies from locale to locale. Consult your HVAC professional for specific
requirements in your area.
Non-vented (recirculating) Installations
Min. ceiling height Max. ceiling height
Electric cooking surface
Gas cooking surface
7' 1" (2.16 m)
7' 4" (2.23 m)
9' 6" (2.9 m)
9' 6" (2.9 m)
NOTE: The range hood chimneys are adjustable and designed to
meet varying ceiling or soffit heights depending on the distance “X”
between the bottom of the range hood and the cooking surface. For
higher ceilings, a Stainless Steel Chimney Extension Kit Part Number
W10272075 is available from your dealer or an authorized parts
distributor. The chimney extension replaces the chimney shipped with
the range hood.
Page 1 of 2
Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.
Ref. W10320584C