48" Commercial Style Dual Fuel Range
with self-cleaning thermal/convection oven
PRODUCT MODEL NUMBERS
OVERALL DIMENSIONS
KDRP487M
NOTE: regulator
located at center
48" (121.9 cm)
bottom of range.
cooktop width
Gas supply: Use 3/4" rigid pipe gas supply line
to the range location. A smaller size pipe on long
runs may result in insufficient gas supply. With
L.P. gas, piping or tubing size can be 1/2"
minimum. If local codes permit, it is
recommended that new flexible metal tubing,
design-certified by AGA or CSA, 4-5 feet long,
5/8-inch I.D., be used for connecting the range to
the rigid gas supply line. A 1/2" male pipe thread is
needed for connection to pressure regulator
female pipe threads. An individual manual shutoff
valve must be located in the same room, but
external to the range.
13-1/2"
(34.3 cm)
49-1/2" (125.7 cm)
overall height
Electrical: A four-wire or three-wire, single
phase, 240-volt, 60-Hz, AC-only, electrical supply
is required on a separate 50 amp circuit, fused on
both sides of the line. A time-delay fuse or circuit
breaker is recommended.
36" (91.4 cm)
cooktop
height with
feet loosened
3/4 turns
1/4" (6.4 mm)
spacer
48" (121.9 cm)
width
26-1/2" (67.3 cm)
depth with
control panel
48" (121.9 cm) range with
all sealed burners shown
CABINET OPENING DIMENSIONS
For minimum
13" (33 cm) max.
upper cabinet depth
clearance to top of
48" (121.9 cm) min.
upper cabinet width
range, see NOTE.*
12" (30.5 cm) min.
clearance from both sides
of range to side wall or
other combustible material
above cooking surface
48-1/4" (122.6 cm)
opening width
18" (45.7 cm)
upper cabinet
to countertop
0" (0 cm) clearance from
both sides and back of
range to adjacent
combustible construction
below cooking surface
8"
(20.3 cm)
3" (7.6 cm) maximum
*NOTE: 49" (124.5 cm) min. when bottom of wood or metal
cabinet is protected by not less than 1/4" (0.64 cm) flame
retardant millboard covered with not less than No. 28 MSG
sheet steel, 0.015" (0.4 mm) stainless steel, 0.024"
(0.6 mm) aluminum or 0.020" (0.5 mm) copper.
gas line height
gas line opening to be
located in this area
40"
(101.6 cm)
55" (139.7 cm) min. clearance between the top of the
cooking platform and the bottom of an unprotected wood
or metal cabinet.
5-1/2" (14 cm)
4"
(10.2 cm)
12"
(30.5 cm)
3-1/2" (8.9 cm)
maximum junction
box height
20"
(50.8 cm)
junction box to be
located in this area
Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.
Ref. 8302571
12-07-04
Download from Www.Somanuals.com. All Manuals Search And Download.
|