INSTRUCTION MANUAL  
144 MHz FM TRANSCEIVER  
TH-K20A  
TH-K20E  
430 MHz FM TRANSCEIVER  
TH-K40A  
TH-K40E  
NOTIFICATION  
This equipment complies with the essential requirements of  
Directive 1999/5/EC.  
The use of the warning symbol  
means the equipment is subject  
to restrictions of use in certain countries.  
This equipment requires a licence and is intended for use in the  
countries as below.  
AT  
IE  
BE  
IT  
DK  
LI  
FI  
FR  
NL  
CZ  
SI  
DE  
NO  
EE  
BG  
GR  
PT  
IS  
ES  
LV  
LU  
CY  
SK  
SE  
LT  
CH  
MT  
GB  
PL  
HU  
RO  
ISO3166  
© B62-2365-00 (K, E, M)  
09 08 07 06 05 04 03 02 01 00  
Download from Www.Somanuals.com. All Manuals Search And Download.  
NOTICES TO THE USER  
One or more of the following statements may be applicable:  
FCC WARNING  
This equipment generates or uses radio frequency energy. Changes or modifications to this  
equipment may cause harmful interference unless the modifications are expressly approved in the  
instruction manual. The user could lose the authority to operate this equipment if an unauthorized  
change or modification is made.  
INFORMATION TO THE DIGITAL DEVICE USER REQUIRED BY THE FCC  
This equipment has been tested and found to comply with the limits for a Class B digital device,  
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection  
against harmful interference in a residential installation.  
This equipment generates, uses and can generate radio frequency energy and, if not  
installed and used in accordance with the instructions, may cause harmful interference to radio  
communications. However, there is no guarantee that the interference will not occur in a particular  
installation. If this equipment does cause harmful interference to radio or television reception,  
which can be determined by turning the equipment off and on, the user is encouraged to try to  
correct the interference by one or more of the following measures:  
Reorient or relocate the receiving antenna.  
Increase the separation between the equipment and receiver.  
Connect the equipment to an outlet on a circuit different from that to which the receiver is  
connected.  
Consult the dealer for technical assistance.  
ATTENTION: (USA only)  
The RBRC Recycle seal found on KENWOOD lithium-ion (Li-ion) battery packs  
indicates KENWOOD’s voluntary participation in an industry program to collect and  
recycle Li-ion batteries after their operating life has expired. The RBRC program is  
an alternative to disposing Li-ion batteries with your regular refuse or in municipal  
waste streams, which is illegal in some areas.  
For information on Li-ion battery recycling in your area, call (toll free)  
1-800-8-BATTERY (1-800-822-8837).  
KENWOOD’s involvement in this program is part of our commitment to preserve our  
environment and conserve our natural resources.  
This device complies with Industry Canada licence-exempt RSS standard(s).  
Operation is subject to the following two conditions: (1) this device may not  
cause interference, and (2) this device must accept any interference, including  
interference that may cause undesired operation of the device.  
i
Download from Www.Somanuals.com. All Manuals Search And Download.  
PRECAUTIONS  
Do not charge the transceiver and battery pack when they are wet.  
Ensure that there are no metallic items located between the transceiver and the battery  
pack.  
Do not use options not specified by KENWOOD.  
If the die-cast chassis or other transceiver part is damaged, do not touch the damaged  
parts.  
If a headset or headphone is connected to the transceiver, reduce the transceiver  
volume. Pay attention to the volume level when turning the squelch off.  
Do not place the microphone cable around your neck while near machinery that may  
catch the cable.  
Do not place the transceiver on unstable surfaces.  
Ensure that the end of the antenna does not touch your eyes.  
When the transceiver is used for transmission for many hours, the radiator and chassis  
will become hot. Do not touch these locations when replacing the battery pack.  
Do not immerse the transceiver in water.  
Always switch the transceiver power off before installing optional accessories.  
For safety reasons, we recommend that the battery charger be connected to an easily  
accessible AC socket.  
Turn the transceiver power off in the following locations:  
In explosive atmospheres (inflammable gas, dust particles, metallic powders, grain  
powders, etc.).  
While taking on fuel or while parked at gasoline service stations.  
Near explosives or blasting sites.  
In aircraft. (Any use of the transceiver must follow the instructions and regulations  
provided by the airline crew.)  
Where restrictions or warnings are posted regarding the use of radio devices,  
including but not limited to medical facilities.  
Near persons using pacemakers.  
Do not disassemble or modify the transceiver for any reason.  
Do not place the transceiver on or near airbag equipment while the vehicle is  
running. When the airbag inflates, the transceiver may be ejected and strike the  
driver or passengers.  
Do not transmit while touching the antenna terminal or if any metallic parts are  
exposed from the antenna covering. Transmitting at such a time may result in a  
high-frequency burn.  
If an abnormal odor or smoke is detected coming from the transceiver, switch the  
transceiver power off immediately, remove the battery pack from the transceiver, and  
contact your KENWOOD dealer.  
Use of the transceiver while you are driving may be against traffic laws. Please  
check and observe the vehicle regulations in your area.  
Do not expose the transceiver to extremely hot or cold conditions.  
Do not carry the battery pack (or battery case) with metal objects, as they may short  
the battery terminals.  
ii  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Danger of explosion if the battery is incorrectly replaced; replace only with the same  
type.  
When operating the transceiver in areas where the air is dry, it is easy to build up  
an electric charge (static electricity). When using an earphone accessory in such  
conditions, it is possible for the transceiver to send an electric shock through the  
earphone and to your ear. We recommend you use only a speaker/microphone in  
these conditions, to avoid electric shocks.  
When attaching a commercial strap to the transceiver, ensure that the strap is  
durable. In addition, do not swing the transceiver around by the strap; you may  
inadvertently strike and injure another person with the transceiver.  
Information concerning the battery pack:  
The battery pack includes flammable objects such as organic solvent.  
Mishandling may cause the battery to rupture producing flames or extreme heat,  
deteriorate, or cause other forms of damage to the battery. Please observe the  
following prohibitive matters.  
Do not disassemble or reconstruct battery!  
The battery pack has a safety function and protection circuit to avoid danger. If they suffer  
serious damage, the battery may generate heat or smoke, rupture, or burst into flame.  
Do not short-circuit the battery!  
Do not join the + and – terminals using any form of metal (such as a paper clip or  
wire). Do not carry or store the battery pack in containers holding metal objects (such  
as wires, chain-necklace or hairpins). If the battery pack is short-circuited, excessive  
current will flow and the battery may generate heat or smoke, rupture, or burst into  
flame. It will also cause metal objects to heat up.  
Do not incinerate or apply heat to the battery!  
If the insulator is melted, the gas release vent or safety function is damaged, or the  
electrolyte is ignited, the battery may generate heat or smoke, rupture, or burst into flame.  
Do not leave the battery near fire, stoves, or other heat generators (areas  
reaching over 80°C/ 176°F)!  
If the polymer separator is melted due to high temperature, an internal short-circuit  
may occur in the individual cells and the battery may generate heat or smoke,  
rupture, or burst into flame.  
Avoid immersing the battery in water or getting it wet by other means!  
If the battery becomes wet, wipe it off with a dry towel before use. If the battery’s  
protection circuit is damaged, the battery may charge at extreme current (or voltage)  
and an abnormal chemical reaction may occur. The battery may generate heat or  
smoke, rupture, or burst into flame.  
Do not charge the battery near fire or under direct sunlight!  
If the battery’s protection circuit is damaged, the battery may charge at extreme  
current (or voltage) and an abnormal chemical reaction may occur. The battery may  
generate heat or smoke, rupture, or burst into flame.  
Use only the specified charger and observe charging requirements!  
If the battery is charged in unspecified conditions (under high temperature over the  
regulated value, excessive high voltage or current over regulated value, or with a  
remodeled charger), it may overcharge or an abnormal chemical reaction may occur.  
The battery may generate heat or smoke, rupture, or burst into flame.  
iii  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Do not pierce the battery with any object, strike it with an instrument, or step  
on it!  
This may break or deform the battery, causing a short-circuit. The battery may  
generate heat or smoke, rupture, or burst into flame.  
Do not jar or throw the battery!  
An impact may cause the battery to leak, generate heat or smoke, rupture, and/or  
burst into flame. If the battery’s protection circuit is damaged, the battery may charge  
at an abnormal current (or voltage), and an abnormal chemical reaction may occur.  
The battery may generate heat or smoke, rupture, or burst into flame.  
Do not use the battery pack if it is damaged in any way!  
The battery may generate heat or smoke, rupture, or burst into flame.  
Do not solder directly onto the battery!  
If the insulator is melted or the gas release vent or safety function is damaged, the  
battery may generate heat or smoke, rupture, or burst into flame.  
Do not reverse the battery polarity (and terminals)!  
When charging a reversed battery, an abnormal chemical reaction may occur. In  
some cases, an unexpected large amount of current may flow upon discharging.  
The battery may generate heat or smoke, rupture, or burst into flame.  
Do not reverse-charge or reverse-connect the battery!  
The battery pack has positive and negative poles. If the battery pack does not  
smoothly connect with a charger or operating equipment, do not force it; check the  
polarity of the battery. If the battery pack is reverse-connected to the charger, it will  
be reverse-charged and an abnormal chemical reaction may occur. The battery may  
generate heat or smoke, rupture, or burst into flame.  
Do not touch a ruptured and leaking battery!  
If the electrolyte liquid from the battery gets into your eyes, wash your eyes with  
fresh water as soon as possible, without rubbing your eyes. Go to the hospital  
immediately. If left untreated, it may cause eye-problems.  
Do not charge the battery for longer than the specified time!  
If the battery pack has not finished charging even after the regulated time has  
passed, stop it. The battery may generate heat or smoke, rupture, or burst into  
flame.  
Do not place the battery pack into a microwave or high pressure container!  
The battery may generate heat or smoke, rupture, or burst into flame.  
Keep ruptured and leaking battery packs away from fire!  
If the battery pack is leaking (or the battery emits a bad odor), immediately remove it  
from flammable areas. Electrolyte leaking from battery can easily catch on fire and  
may cause the battery to generate smoke or burst into flame.  
Do not use an abnormal battery!  
If the battery pack emits a bad odor, appears to have different coloring, is deformed,  
or seems abnormal for any other reason, remove it from the charger or operating  
equipment and do not use it. The battery may generate heat or smoke, rupture, or  
burst into flame.  
iv  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CONTENTS  
PREPARATION ................................................................................................... 1  
SUPPLIED ACCESSORIES........................................................................... 1  
INSTALLING THE ANTENNA......................................................................... 1  
INSTALLING THE BATTERY PACK .............................................................. 2  
INSTALLING THE BELT CLIP........................................................................ 2  
CHARGING THE BATTERY PACK................................................................ 3  
CONNECTING TO THE PC............................................................................ 5  
GETTING ACQUAINTED..................................................................................... 6  
PANEL............................................................................................................ 6  
DISPLAY......................................................................................................... 8  
BASIC OPERATION.......................................................................................... 10  
SWITCHING THE POWER ON/OFF............................................................ 10  
ADJUSTING THE VOLUME......................................................................... 10  
ADJUSTING THE SQUELCH....................................................................... 10  
SELECTING A FREQUENCY....................................................................... 11  
TRANSMITTING/ RECEIVING..................................................................... 11  
DIRECT FREQUENCY ENTRY.................................................................... 12  
SELECTING AN OUTPUT POWER............................................................. 12  
BACKLIGHT ................................................................................................. 13  
MONITOR..................................................................................................... 13  
LOCK FUNCTION ........................................................................................ 14  
MENU SETUP.................................................................................................... 15  
WHAT IS A MENU?...................................................................................... 15  
MENU ACCESS ........................................................................................... 15  
MENU FUNCTION LIST............................................................................... 16  
MEMORY CHANNELS ...................................................................................... 18  
SIMPLEX & REPEATER OR ODD-SPLIT MEMORY CHANNEL?............... 18  
STORING SIMPLEX AND STANDARD REPEATER FREQUENCIES ........ 19  
STORING ODD-SPLIT REPEATER FREQUENCIES.................................. 20  
RECALLING A MEMORY CHANNEL........................................................... 20  
NAMING A MEMORY CHANNEL................................................................. 21  
MEMORY DISPLAY TYPE........................................................................... 22  
CLEARING A MEMORY CHANNEL............................................................. 22  
CALL CHANNEL........................................................................................... 23  
MEMORY CHANNEL TRANSFER............................................................... 24  
CHANNEL DISPLAY MODE......................................................................... 24  
SCAN ................................................................................................................. 26  
BAND SCAN................................................................................................. 26  
PROGRAM SCAN ........................................................................................ 27  
MEMORY SCAN........................................................................................... 28  
CALL SCAN.................................................................................................. 28  
PRIORITY SCAN.......................................................................................... 28  
MEMORY CHANNEL LOCKOUT................................................................. 29  
SELECTING A SCAN RESUME METHOD.................................................. 30  
v
Download from Www.Somanuals.com. All Manuals Search And Download.  
OPERATING THROUGH REPEATERS............................................................ 31  
SELECTING AN OFFSET DIRECTION (SHIFT).......................................... 31  
SELECTING AN OFFSET FREQUENCY..................................................... 32  
TONE FUNCTION ........................................................................................ 32  
AUTOMATIC REPEATER OFFSET............................................................. 34  
REVERSE FUNCTION................................................................................. 34  
TRANSMITTING A 1750 Hz TONE.............................................................. 35  
SIGNALING........................................................................................................ 36  
CTCSS.......................................................................................................... 36  
DCS .............................................................................................................. 37  
CROSS TONE.............................................................................................. 39  
DTMF FUNCTIONS............................................................................................ 40  
MANUAL DIALING ....................................................................................... 40  
AUTOMATIC DIALER................................................................................... 40  
ADJUSTING THE DTMF CODE TRANSMIT SPEED .................................. 41  
DTMF TX HOLD ........................................................................................... 42  
ADJUSTING THE PAUSE DURATION ........................................................ 42  
DTMF LOCK................................................................................................. 42  
AUXILIARY FUNCTIONS .................................................................................. 43  
PROGRAMMABLE VFO............................................................................... 43  
FREQUENCY STEP SIZE............................................................................ 44  
TONE ALERT ............................................................................................... 44  
POWER ON MESSAGE............................................................................... 45  
BEEP FUNCTION......................................................................................... 46  
LOCK TYPE.................................................................................................. 46  
BATTERY SAVER........................................................................................ 47  
APO (AUTO POWER OFF).......................................................................... 48  
NARROW BAND FM OPERATION.............................................................. 48  
BEAT SHIFT................................................................................................. 49  
VOX (VOICE-OPERATED TRANSMIT) ....................................................... 49  
TIME-OUT TIMER ........................................................................................ 51  
BUSY CHANNEL LOCKOUT........................................................................ 51  
TX INHIBIT ................................................................................................... 52  
MICROPHONE SENSITIVITY...................................................................... 52  
PROGRAMMABLE FUNCTION KEYS......................................................... 52  
MICROPHONE KEY LOCK.......................................................................... 53  
BATTERY TYPE........................................................................................... 53  
WEATHER ALERT (TH-K20A K TYPE ONLY)................................................. 54  
WEATHER ALERT ON/ OFF........................................................................ 54  
WEATHER CHANNEL.................................................................................. 54  
WEATHER CHANNEL SCAN....................................................................... 54  
APPENDIX ......................................................................................................... 55  
OPTIONAL ACCESSORIES......................................................................... 55  
MAINTENANCE............................................................................................ 55  
TROUBLESHOOTING.................................................................................. 56  
TRANSCEIVER RESET ............................................................................... 58  
SPECIFICATIONS........................................................................................ 59  
vi  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PREPARATION  
SUPPLIED ACCESSORIES  
After carefully unpacking the transceiver, identify the items listed in the table  
below. We recommend you keep the box and packaging for shipping.  
Quantity  
Item  
Comments  
K type  
E type  
M type  
Antenna  
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
Li-ion battery pack  
Battery charger  
Belt clip  
KNB-63L  
with AC adapter (KSC-35S)  
KBH-18  
Warranty card  
English  
French  
Spanish  
Italian  
Instruction manual  
German  
Dutch  
Turkish  
Chinese  
INSTALLING THE ANTENNA  
Hold the supplied antenna by its base, then screw it into the connector on the top  
panel of the transceiver until secure.  
Note: The antenna is neither a handle, a key ring retainer, nor a speaker/ microphone  
attachment point. Using the antenna in these ways may damage the antenna and degrade  
your transceiver’s performance.  
1
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLING THE BATTERY PACK  
Note: Because the battery pack is provided uncharged, you must charge the battery pack  
before using it with the transceiver. To charge the battery pack, refer to “CHARGING THE  
BATTERY PACK ” {page 3}.  
1 To install the battery pack, align the base of the  
battery pack with the transceiver, then press  
the battery pack into place until the lock lever is  
Lock lever  
secure.  
2 To remove the battery pack, push the lock lever  
up, then pull the battery pack away from the  
transceiver.  
Lock lever  
INSTALLING THE BELT CLIP  
If desired, you can install the supplied belt clip to the transceiver.  
1 Remove the battery pack, as described above.  
2 To install the belt clip, align the guides of the  
belt clip with the grooves on the rear of the  
Belt clip  
battery pack, then slide the belt clip into place  
until the lock lever is secure.  
3 To remove the belt clip, push the lock lever  
towards the transceiver while sliding the belt  
clip up.  
Lock lever  
2
Download from Www.Somanuals.com. All Manuals Search And Download.  
CHARGING THE BATTERY PACK  
The battery pack can be charged after it has been installed onto the transceiver.  
(The battery pack is provided uncharged for safety purposes.)  
1 Confirm that the transceiver power is OFF.  
While charging the transceiver with a battery pack  
installed, be sure to turn the transceiver power  
OFF.  
2 Plug the AC adapter cable into the jack located  
on the rear of the charger.  
3 Plug the AC adapter into an AC outlet.  
4 Slide a battery pack or a transceiver equipped  
with a battery pack into the charging slot.  
Make sure the metal contacts of the battery pack  
mate securely with the charger terminals.  
The indicator lights red and charging starts.  
5 When charging is completed, the indicator  
lights green. Remove the battery pack or the  
transceiver from the charging slot.  
Charging slot  
Indicator  
When the charger will not be used for a long time,  
unplug the AC adapter from the AC outlet.  
Note:  
Using the transceiver while charging its battery pack will interfere with correct charging.  
If the operating time of a battery pack decreases although the battery pack is fully and  
correctly charged, the battery pack life is over. Replace the battery pack.  
The ambient temperature should be from 41°F (5°C) to 104°F (40°C) while charging is in  
progress.  
The charging times provided are obtained when a battery pack discharged to 3 V/cell x 2  
is charged at normal temperatures. This charging time varies depending on the degree of  
discharge and the ambient charging temperature.  
This charger may be suitable to charge battery packs not listed herein, due to further  
technology development.  
If the battery pack contacts are not properly mated with the charger terminals, the  
indicator may blink red or may remain unlit. To resolve this problem, reinsert the battery  
pack after cleaning the battery pack contacts and the charger terminals.  
When using this equipment near a radio or television, you may experience interference  
with reception.  
While charging, do not connect the PC Interface cable to the transceiver.  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
Approximate Charging Times  
3 hours  
Charger Status Table  
Indicator color  
Red  
Meaning  
A battery pack is in the charging slot and charging has  
started.  
The battery pack is defective or the battery pack  
contacts are not properly mated with those of the  
charger.  
Blinking Red  
Green  
Charging is completed; remove the battery pack or the  
transceiver from the charging slot.  
The temperature of the battery pack has not satisfied  
the charging start temperature. Remove the battery  
pack from the charger and wait until it reaches a normal  
temperature before charging it again.  
Alternates flashing green  
and orange  
Battery Life  
Before you operate the transceiver outside, using a battery pack, it is important to  
know how long the battery pack will last. The operating times listed in the table  
below are measured under the following cyclic conditions:  
TX: 6 seconds, RX: 6 seconds, Stand-by: 48 seconds (Battery Saver: ON)  
We recommend you carry extra battery packs with you, in case the battery pack  
becomes depleted.  
Battery Type  
Output Power  
High  
Operating Time/ Hours (Approx.)  
6 (KNB-63L)  
8.5 (KNB-63L)  
10.5 (KNB-63L)  
8 (KNB-65L)  
11.5 (KNB-65L)  
14 (KNB-65L)  
KNB-63L/ KNB-65L  
(7.4 V)  
Medium  
Low  
High  
6
8
BT-16 (9 V)  
<AAA (LR03) alkaline  
batteries x 6>  
Medium  
Low  
10  
Note:  
The high power transmission output while using the battery case (BT-16) is 3.5 W and  
lower. Additionally, as is characteristic of alkaline batteries, transmission output will  
decrease as time progresses. We recommend using low power when using the battery  
case.  
Internal resistance levels differ, depending on the battery, so when using Alkaline  
batteries there are times when the actual operating time may be shorter than normal.  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
Connecting to a Cigarette Lighter Socket  
To use the cigarette lighter socket, use the optional KVC-22 DC vehicular charger  
adapter. When using the Charger, attach it to the vehicle as shown below.  
To the jack  
To the cigarette lighter socket  
DC power cable (supplied with the KVC-22)  
Charger + KVC-22  
Note: Refer to the KVC-22 instruction manual for how to connect the charger to a cigarette  
lighter socket.  
CAUTION: Do not fix the Charger near an airbag nor in places where it will be a hindrance  
while driving.  
CONNECTING TO THE PC  
Use the optional PG-4Y PC interface cable to connect the transceiver to a PC.  
Plug the Speaker/ Microphone connector to the SP/MIC jack and the DB-9  
connector to one of the COM (serial) ports on your PC.  
To PC  
PG-4Y  
To download the MCP-5A software, go to:  
(This URL may change without notice.)  
Note: No guarantee is provided for data that may be erased or destroyed due to  
malfunctions of this unit or your computer.  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
GETTING ACQUAINTED  
PANEL  
Microphone  
Speaker  
PWR/VOL control  
Turn clockwise to switch the transceiver ON. To switch the transceiver OFF,  
turn counterclockwise until a click sounds. Rotate to adjust the volume level.  
TX-RX LED  
Lights red while transmitting and green while receiving a signal.  
ENC Control  
Rotate to select an operating frequency, Memory channel, Menu number, and  
setting value or to change the scan direction, etc.  
[PTT] (Push to talk) switch  
Press and hold, then speak into the microphone to transmit.  
[MONI]  
Press and hold to unmute the speaker in order to monitor signals. Release  
[MONI] to return to normal operation {page 13}.  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
Keypad  
Use the keypad to perform the following operations. Additionally, you can use  
the 10-key keypad for direct frequency entry and manually transmitting DTMF  
tones.  
Key name  
Press  
[KEY]  
Operation  
Ref. page  
To enter MHz tuning mode.  
To turn the Function ON.  
11  
[F]  
A
[F] - [KEY] To turn the Function OFF.  
[KEY] (1s) To turn the Lock function ON and OFF.  
14  
11  
[KEY]  
To enter VFO mode.  
To copy the current Memory channel or Call  
channel to the VFO (memory shift).  
[VFO]  
[MR]  
B
C
D
[F] - [KEY]  
24  
[KEY] (1s) To start Band scan.  
26  
18  
[KEY]  
To enter Memory Channel mode.  
To store the current operating frequency in the  
Memory channel.  
[F] - [KEY]  
19  
28  
[KEY] (1s) To start Memory scan  
[KEY]  
To select the Call channel.  
23  
To store the current operating frequency to the  
Call channel.  
[CALL]  
[F] - [KEY]  
[KEY] (1s) To start CALL scan.  
28  
15  
[MENU]  
[TONE]  
1
2
[KEY]  
[KEY]  
To enter Menu mode.  
To select the Signaling (Tone, CTCSS, DCS or  
Cross tone) function.  
32, 36,  
37, 39  
[LOW]  
[SQL]  
3
4
[KEY]  
[KEY]  
To select an Output power.  
12  
10  
To enter Squelch Level Adjustment mode.  
To enter the Tone frequency, CTCSS  
frequency or DCS code setup mode.  
[KEY]  
32, 36,  
37, 39  
[T.SEL]  
5
To start Tone frequency, CTCSS frequency or  
DCS code scan.  
[KEY] (1s)  
[ ]  
[SHIFT]  
[REV]  
[PF]  
6
7
8
9
[KEY]  
[KEY]  
[KEY]  
[KEY]  
To enter the Tone Alert function setup mode.  
To select an Offset direction.  
44  
31  
34  
52  
To turn the Reverse function ON or OFF.  
To activate the Program function.  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
Key name  
[LAMP]  
Press  
[KEY]  
Operation  
To turn the Backlight ON.  
Ref. page  
13  
[F] - [KEY] To keep the Backlight ON continuously.  
[STEP]  
[ENT]  
0
[KEY]  
[KEY]  
To enter the Frequency step size setup mode.  
To enter Direct frequency entry mode.  
44  
12  
#
MIC/ SP Jack  
Connect the optional Speaker/ Microphone to this jack.  
Also, attach an optional PG-4Y PC interface cable to this jack, to connect the  
transceiver to a PC {page 5}.  
DISPLAY  
Indicator  
Description  
Appears while using Medium output power.  
Appears while using Low output power.  
Appears when the Cross Tone function is ON.  
Appears when the Tone function is ON.  
Appears when the CTCSS function is ON.  
Appears when the DCS function is ON.  
Appears when Weather Alert is ON. Blinks when  
receiving a signal. (TH-K20A K type only)  
Appears when the Reverse function is ON.  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
Indicator  
Description  
Appears when the Shift function is set to plus.  
Appears when the Shift function is set to minus.  
Appears when the Shift function is set to –7.6 MHz.  
(TH-K40E (E type) only)  
Displays the operating frequency, setting  
information, etc.  
Displays the Memory channel number.  
Appears when the Memory channel Lockout  
function is ON, for the selected Memory channel.  
Appears when the selected Memory channel is  
registered while in Memory Input mode.  
Appears while in Narrow FM mode.  
Appears while in Function mode.  
Performs as an S meter when receiving a signal  
and displays the battery power remaining while Low  
power transmitting.  
Appears when the Tone Alert function is ON.  
Appears when Priority scan is ON.  
Appears when the VOX function is ON.  
Appears when the Lock function is ON.  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
BASIC OPERATION  
SWITCHING THE POWER ON/OFF  
Turn the PWR/VOL control clockwise to switch the transceiver ON.  
The power on message momentarily appears on the display.  
Turn the PWR/VOL control counterclockwise to switch the transceiver OFF.  
ADJUSTING THE VOLUME  
Rotate the PWR/VOL control to adjust the volume. Clockwise increases the  
volume and counterclockwise decreases it.  
If you are not receiving a signal, press and hold [MONI] to unmute the speaker, then  
adjust the volume control to a comfortable audio output level.  
ADJUSTING THE SQUELCH  
The purpose of Squelch is to mute the speaker when no signals are present.  
With the squelch level correctly set, you will hear sound only while actually  
receiving signals. The higher the selected squelch level, the stronger the signals  
must be to receive. The appropriate squelch level depends on the ambient RF  
noise conditions.  
1 Press [SQL].  
The squelch level appears on the display.  
2 Rotate the ENC control to adjust the level.  
Select the level at which the background noise is just eliminated when no signal is  
present.  
The higher the level, the stronger the signals must be to receive.  
6 different levels can be set. 0: Minimum ~ 5: Maximum; 2 is the default value.  
3 Press any key other than [MONI] or [LAMP] to store the new setting and exit  
the squelch adjustment.  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SELECTING A FREQUENCY  
VFO MODE  
This is the basic mode for changing the operating frequency. Rotate the ENC  
control clockwise to increase the frequency and counterclockwise to decrease  
the frequency.  
MHz TUNING MODE  
If the desired operating frequency is far away from the current frequency, it is  
quicker to use the MHz Tuning Mode.  
To adjust the MHz digit:  
1 Press [F].  
The MHz digit blinks.  
2 Rotate the ENC control to select the desired MHz value.  
3 After selecting the desired MHz value, press [F] or [ENT] to exit the MHz  
Tuning Mode and return to normal VFO Mode.  
4 Continue adjusting the frequency as necessary, using the ENC control.  
TRANSMITTING/ RECEIVING  
1 To transmit, hold the transceiver approximately 5 cm (2 inches) from your  
mouth, then press and hold [PTT] and speak into the microphone in your  
normal tone of voice.  
The TX-RX LED lights red.  
2 When you finish speaking, release [PTT].  
The TX-RX LED lights green while receiving a signal.  
Note: If you continuously transmit for longer than the time specified in Menu No. 19 (default  
is 10 minutes), the internal time-out timer generates a warning beep and the transceiver  
stops transmitting. In this case, release [PTT] and let the transceiver cool down for a while,  
then press [PTT] again to resume transmitting.  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
DIRECT FREQUENCY ENTRY  
In addition to rotating the ENC control, there is another way to select the  
frequency. When the desired frequency is far away from the current frequency,  
you can directly enter a frequency using the numeric keypad.  
1 Press [VFO].  
You must be in the VFO Mode to make the direct frequency entry.  
2 Press [ENT].  
3 Press the numeric keys ([STEP] (0) to [PF] (9)) to enter your desired  
frequency. [LAMP] ( ) allows you to complete the MHz digits entry.  
Pressing [ENT] fills all remaining digits (the digits you did not enter) with 0 and  
completes the entry. For example, to select 145.000 MHz, press [MENU] (1),  
[SQL] (4), and [T.SEL] (5), then press [ENT] to complete the entry.  
If you want to revise the MHz digits only, leaving the kHz digits as they are, press  
[VFO] in place of [ENT].  
Note:  
If the entered frequency does not match the current frequency step size, the frequency is  
automatically rounded down to the next available frequency.  
When the desired frequency cannot be entered exactly, confirm the frequency step size.  
If you rotate the ENC control while entering the frequency, the transceiver clears the  
entry.  
SELECTING AN OUTPUT POWER  
Selecting a lower transmit power is the best way to reduce battery consumption, if  
communication is still reliable.  
Press [LOW] to toggle between high, medium and low power.  
No icon appears when using high transmit power.  
The “  
The “  
” icon appears when using medium transmit power.  
” icon appears when using lower transmit power.  
Note: When the transceiver overheats due to ambient high temperature or continuously  
transmitting, the protective circuit may activate, lowering the transmit output power.  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
REMAINING BATTERY CAPACITY  
You can confirm the remaining battery capacity when you transmit in low power.  
To check the remaining capacity:  
The bar-graph shows the remaining battery capacity.  
:
High battery power  
:
:
:
Low battery power  
or no display :  
Recharge or replace the batteries.  
Note: You may not be able to transmit at high power if the battery remaining indicator shows  
low battery power.  
BACKLIGHT  
Press [LAMP] to illuminate the display and keys.  
The light turns OFF approximately 5 seconds after releasing [LAMP].  
Press any key (including [PTT]) other than [LAMP] while the display and keys are lit to  
restart the 5-second timer.  
Continuing to press [LAMP] after having pressed it will illuminate the display and keys  
for as long as you hold the key.  
Press [F] - [LAMP] to keep the light ON continuously.  
The light remains ON until you press [F] - [LAMP] again.  
MONITOR  
When you are receiving while the squelch function is ON, weak signals may  
become intermittent.  
If the CTCSS, DCS or Tone Alert function is ON, you may want to disable the  
squelch function temporarily to monitor the current channel activities.  
1 Press and hold [MONI].  
The speaker is unmuted and you can monitor the signals.  
2 Release [MONI] to return to normal operation.  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
LOCK FUNCTION  
The lock function disables most of the keys to prevent you from accidentally activating  
a function.  
1 Press [F] (1s) to turn the Lock function ON.  
The “  
” icon appears when the Lock function is ON.  
The following keys cannot be locked:  
[F], [PTT], [LAMP], [MONI], [SQL], PWR/VOL control and microphone PF key.  
2 Press [F] (1s) to unlock the keys.  
Note:  
You cannot perform the Transceiver Reset while the Lock function is ON.  
You can select the lock type from Menu No. 3.  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MENU SETUP  
WHAT IS A MENU?  
Many functions on this transceiver are selected or configured via a software-  
controlled Menu rather than through the physical controls of the transceiver.  
Once you become familiar with the Menu system, you will appreciate its  
versatility. You can customize the various timings, settings and programming  
functions on this transceiver to meet your needs without using many controls and  
switches.  
MENU ACCESS  
1 Press [MENU].  
A brief explanation of the Menu and the Menu No. appear on the display.  
2 Rotate the ENC control to select your desired Menu No.  
3 Press [F] < OK > to configure the parameter of the currently selected  
Menu No.  
4 Rotate the ENC control to select your desired parameter.  
5 Press [F] < OK > to store the new setting.  
6 Press [MENU] or [PTT] to exit Menu mode.  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MENU FUNCTION LIST  
Ref.  
Page  
No.  
Display  
Description  
Setting Values  
Default Setting  
Power On  
message  
P.ON.MSG  
1
Up to 6 characters  
45  
46  
BEEP  
LOCK  
2
3
Key Beep  
Lock type  
OFF/ ON  
ON  
KEY/ FRQ/ KEY.FRQ  
KEY.FRQ  
OFF/ 0.2/ 0.4/ 0.6/ 0.8/  
1.0/ 2.0/ 3.0/ 4.0/ 5.0  
(sec)  
SAVE  
APO  
4
5
Battery saver  
1.0 (sec)  
30 (min)  
47  
48  
Automatic Power- OFF/ 30/ 60/ 90/ 120/  
OFF  
180 (min)  
TH-K20A/E:  
Programmable  
VFO  
136 ~ 173 MHz  
TH-K40A/E:  
400 ~ 469 MHz  
P.VFO  
6
43  
It differs  
between the  
model and  
type.  
Repeater Offset  
Frequency  
OFFSET  
ARO  
7
8
0.000 ~ 29.950 (MHz)  
OFF/ ON  
31  
34  
Automatic  
Repeater Offset  
N.FM  
9
Narrow FM  
Beat shift  
OFF/ ON  
OFF  
OFF  
48  
49  
21  
B.SHIFT  
M.NAME  
10  
11  
OFF/ ON  
Memory name  
Up to 6 characters  
Memory display  
type  
M.DISP  
L.OUT  
12  
13  
14  
NAME/ FREQ  
OFF/ ON  
NAME  
OFF  
TO  
22  
29  
30  
Memory channel  
lockout  
Scan resume  
method  
RESUME  
TO/ CO/ SEEK  
PR.SCAN  
VOX  
15  
16  
17  
Priority scan  
VOX gain  
OFF/ ON  
OFF/ 1 ~ 9  
OFF/ ON  
OFF  
OFF  
OFF  
28  
49  
VOX.BSY  
VOX busy  
50  
250/ 500/ 750/ 1000/  
1500/ 2000/ 3000 (ms)  
VOX.DLY  
TOT  
18  
19  
20  
VOX delay time  
Time-out Timer  
500 (ms)  
10.0 (min)  
OFF  
0.5/ 1.0/ 1.5/ 2.0/ 2.5/  
3.0/ 3.5/ 4.0/ 4.5/ 5.0/  
10.0 (min)  
51  
Busy channel  
lockout  
BCL  
OFF/ ON  
16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Ref.  
Page  
No.  
Display  
Description  
TX inhibit  
Setting Values  
OFF/ ON  
Default Setting  
TX.INH  
21  
22  
OFF  
Microphone  
Sensitivity  
M.SENS  
HIGH/ MEDIUM/ LOW MEDIUM  
It differs  
1750/ WX/ N.FM/  
PR.SCAN/ M.DISP  
between the  
model and  
type.  
23  
PF KEY  
Panel PF key  
52  
Microphone PF 1  
key  
VFO/ MR/ CALL/ UP/  
DOWN/ TONE/ T.SEL/  
PF 1  
PF 2  
24  
25  
26  
27  
28  
VFO  
MR  
Microphone PF 2 SHIFT/ REV/ 1750/  
key  
WX/ N.FM/ PR.SCAN/  
M.DISP/ SQL/ LOW/  
STEP/ L.OUT/ MONI/  
Microphone PF 3  
key  
PF 3  
CALL  
OFF  
0 ch  
Microphone key  
Lock  
MIC.LK  
DTMF.MR  
OFF/ ON  
53  
DTMF memory  
(Automatic dialer)  
0 ~ F ch  
Up to 16 digits  
40  
41  
DT.SPD  
29  
30  
DTMF TX speed  
DTMF TX hold  
50/ 100/ 150 (ms)  
OFF/ ON  
100 (ms)  
OFF  
DT.HOLD  
100/ 250/ 500/ 750/  
1000/ 1500/ 2000 (ms)  
DT.PAUS  
31  
DTMF pause time  
500 (ms)  
42  
DT.LOCK  
1750.HD  
BATT  
32  
33  
34  
DTMF key Lock  
1750 Hz TX hold  
Battery type  
OFF/ ON  
OFF  
OFF/ ON  
OFF  
35  
53  
54  
58  
LI-ION/ ALKALI  
OFF/ ON  
LI-ION  
OFF  
*
WX.ALT  
RESET  
35  
Weather alert  
Reset type  
99  
PART/ FULL  
PART  
* Available only for the TH-K20A K type model.  
Note: Default settings are subject to change.  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MEMORY CHANNELS  
In Memory channels, you can store frequencies and related data that you often  
use. Then you need not reprogram the data every time. You can quickly recall a  
programmed channel by simple operation. A total of 200 Memory channels are  
available.  
SIMPLEX & REPEATER OR ODD-SPLIT MEMORY CHANNEL?  
You can use each memory channel as a simplex & repeater channel or as an  
odd-split channel. Store only one frequency to use as a simplex & repeater  
channel or two separate frequencies to use as an odd-split channel. Select either  
application for each channel depending on the operations you have in mind.  
Simplex & Repeater channels allow:  
Simplex frequency operation  
Repeater operation with a standard offset (if an offset direction is stored)  
Odd-split channels allow:  
Repeater operation with a non-standard offset  
The data listed below can be stored in each Memory channel:  
Simplex &  
Parameter  
Repeater  
Odd-split  
Receive/ Transmit frequency  
Receive/ Transmit frequency step size  
Receive only frequency  
Receive only frequency step size  
Transmit only frequency  
Transmit only frequency step size  
Offset frequency  
Yes  
Yes  
No  
No  
No  
Yes  
Yes  
Yes  
Yes  
No  
No  
No  
No  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
Tone On/Off  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
No  
Tone frequency  
CTCSS On/Off  
CTCSS frequency  
DCS On/Off  
DCS code  
Cross tone On/Off  
Shift (Offset direction)  
Reverse On/Off  
No  
18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Simplex &  
Repeater  
Parameter  
Odd-split  
Memory channel lockout *  
Narrow FM  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
Beat shift  
* Program Scan Memory and the Priority channel cannot be stored as ON or OFF for Memory  
channel lockout.  
STORING SIMPLEX AND STANDARD REPEATER FREQUENCIES  
1 Press [VFO] to enter VFO mode.  
2 Rotate the ENC control to select your desired frequency.  
You can also directly enter a desired frequency using the keypad.  
3 If storing a standard repeater frequency, select the following data:  
Offset direction  
Tone function, if necessary  
CTCSS/ DCS function, if necessary  
If storing a simplex frequency, you may select other related data (CTCSS or DCS  
settings, etc.).  
4 Press [F] - [MR].  
A memory channel number appears and blinks.  
When the channel has stored data, the “  
” icon appears.  
Memory channel numbers L0/U0 ~ L2/U2 and Pr (Priority Channel) are reserved for  
other functions.  
5 Rotate the ENC control to select the memory channel in which you want to  
store the data.  
6 Press [MR] to store the data to the channel.  
Note: If you store the data in a Memory channel that already has data stored in it, the old  
data will be cleared and the new data will be stored.  
19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
STORING ODD-SPLIT REPEATER FREQUENCIES  
Some repeaters use a receive/transmit frequency pair with a non-standard offset.  
If you store two separate frequencies in a memory channel, you can operate on  
those repeaters without programming the offset frequency and direction.  
1 Store the desired receiving frequency and related data by following the  
procedure given for simplex or standard repeater frequencies.  
2 Press [VFO], then rotate the ENC control to select the desired transmit  
frequency.  
You can also directly enter a desired frequency using the keypad.  
3 Press [F] - [MR], then rotate the ENC control to select the memory channel  
you programmed in step 1.  
4 Press [PTT] + [MR].  
The transmit frequency is stored in the memory channel.  
Note: When you recall an odd-split memory channel, “ ” and “  
” appear on the display.  
To confirm the transmit frequency, press [REV] (Reverse function).  
RECALLING A MEMORY CHANNEL  
USING THE ENC CONTROL  
1 Press [MR] to enter Memory Recall Mode. The memory channel last used is  
recalled.  
2 Rotate the ENC control to select your desired memory channel.  
You cannot recall an empty memory channel.  
To restore VFO Mode, press [VFO].  
USING A NUMERIC KEYPAD  
You can also recall a memory channel by entering a desired memory channel  
number with the keypad.  
1 Press [MR] to enter Memory Recall Mode.  
2 Press [ENT], then enter the channel number.  
For example, to recall channel 149, press [ENT], [MENU] (1), [SQL] (4), [PF] (9).  
You can also enter a memory channel number that is less than 10 by pressing  
[ENT] after entering the channel number. For example, to recall memory channel  
9, press [ENT], [PF] (9), [ENT]. You can also press [ENT], [STEP] (0), [PF] (9).  
20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Note:  
You cannot recall an empty memory channel. An error beep sounds.  
You cannot recall the Program Scan memory channels (L0/U0 ~ L2/U2) or Priority  
Channel (Pr) using the numeric keypad.  
When recalling an odd-split memory channel, “ ” and “  
Press [REV] (Reverse function) to display the transmit frequency.  
” appear on the display.  
After recalling a memory channel, you may modify data such as Tone or CTCSS.  
However, these settings are cleared once you select another channel or the VFO Mode.  
To permanently store the data, overwrite the channel contents.  
NAMING A MEMORY CHANNEL  
You can name memory channels using up to 6 alphanumeric characters. When  
you recall a named memory channel, its name appears on the display in place of  
the stored frequency. Names can be call signs, repeater names, cities, names of  
people, etc.  
1 Press [MR], then rotate the ENC control to select your desired memory  
channel.  
2 Enter Menu mode and access Menu No. 11 (M.NAME), then press [F].  
A blinking cursor appears.  
3 Rotate the ENC control to select a desired alphanumeric character.  
You can enter the following alphanumeric characters:  
0 ~ 9, A ~ Z, - (hyphen), / (slash), and a space.  
4 Press [MR].  
The cursor will move to the next digit.  
You can move the cursor to the left or right by pressing [VFO] or [MR].  
Press [CALL] to delete the character at the current cursor position.  
5 Repeat steps 3 and 4 to enter up to 6 digits.  
6 Press [F] to store the name.  
7 Press [MENU] or [PTT] to exit Menu mode.  
Note:  
You cannot name the Call Channel.  
You cannot assign a Memory name to a channel that does not contain data.  
You can overwrite stored names by repeating steps 2 to 6.  
The stored name is erased when you clear the Memory channel data.  
21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MEMORY DISPLAY TYPE  
After storing a Memory name, the Memory name appears in place of the  
operating frequency. However, you can still display the operating frequency, if  
desired. To display the frequency rather than Memory name, access Menu No.  
12 (M.DISP) and select “FREQ”. This menu toggles the display mode between  
the Memory name (“NAME”) and frequency display (“FREQ”).  
1 Enter Menu mode and access Menu No. 12 (M.DISP), then press [F].  
2 Rotate the ENC control to set the display type to “NAME” or “FREQ”, then  
press [F] to store the setting.  
3 Press [MENU] or [PTT] to exit Menu mode.  
Note: Even when set to “NAME”, the frequency will appear on the display while pressing  
[MONI].  
CLEARING A MEMORY CHANNEL  
To clear the data from an individual memory channel:  
1 Recall the memory channel you want to clear.  
2 Turn the transceiver OFF  
3 Press [MR] + Power ON.  
A confirmation message appears.  
4 Press [MR] to clear the channel data.  
The contents of the memory channel are cleared.  
To cancel, press any key other than [MR], [MONI] or [LAMP].  
Note:  
The Call Channel data cannot be cleared.  
You can also clear the Priority Channel and the L0/U0 ~ L2/U2 channels.  
While the transceiver is in Channel Display Mode or Lock function is activated, you  
cannot clear the channel data.  
22  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CALL CHANNEL  
The Call Channel can be recalled instantly, no matter the frequency on which you  
are operating the transceiver. For instance, you may use the Call Channel as an  
emergency channel within your group. In this case, Call Scan will be useful.  
The default Call Channel frequency is 144.000 MHz (TH-K20A/E)/ 430.000 MHz  
(TH-K40A/E).  
Note: Unlike memory channels 0 to 199, the Call Channel cannot be cleared.  
RECALLING THE CALL CHANNEL  
Press [CALL] to recall the Call Channel.  
The Call Channel frequency and “C” appear.  
To return to the previous frequency, press [CALL] again.  
REPROGRAMMING THE CALL CHANNEL  
1 Select your desired frequency and related data (Tone, CTCSS, DCS, or offset  
direction, etc.).  
When you program the Call Channel as an odd-split channel, select a receiving  
frequency first.  
2 Press [F] - [CALL].  
The selected frequency and related data are stored in the Call Channel.  
To also store a separate transmit frequency, continue with the following steps.  
3 Select the desired transmit frequency.  
4 Press [F], then press [PTT] + [CALL].  
The separate transmit frequency is stored in the Call Channel.  
Note:  
When you recall an odd-split Call Channel, “ ” and “  
” appear on the display.  
Transmit offset status and Reverse status are not stored in an odd-split Call Channel.  
23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MEMORY CHANNEL TRANSFER  
MEMORY TO VFO TRANSFER  
After retrieving frequencies and associated data from Memory Recall mode, you  
can copy the data to the VFO. This function is useful, for example, when the  
frequency you want to monitor is near the frequency stored in a memory channel.  
1 Press [MR], then turn the ENC control to recall a desired memory channel.  
2 Press [F] - [VFO] to copy the memory channel data to the VFO.  
Note:  
When transferring an odd-split channel, the Reverse status, Offset direction, and  
Transmit frequency are not transferred.  
You can also transfer the Program Scan memory channels (L0/U0 ~ L2/U2) and Priority  
channel (Pr) to the VFO.  
When selecting the Call channel, rotating the ENC control will transfer the data to the  
VFO.  
CHANNEL TO CHANNEL TRANSFER  
You can also copy channel information from one memory channel to another.  
This function is useful when storing frequencies and associated data that you  
temporarily change in Memory Recall mode.  
1 Press [MR], then turn the ENC control to recall a desired memory channel.  
2 Press [F] - [MR].  
3 Select the memory channel where you would like the data copied, using the  
ENC control.  
4 Press [MR] to copy the memory channel data to the new channel.  
Note: When transferring to the Program Scan memory channels (L0/U0 ~ L9/U9) and the  
Priority channel (Pr), the Memory Channel Lockout information is not copied.  
CHANNEL DISPLAY MODE  
While in this mode, the transceiver displays only memory channel numbers (or  
Memory names if they have been stored) instead of frequencies.  
Press [PTT] + [MR] + Power ON.  
The transceiver displays the memory channel number in place of the operating  
frequency.  
To recover normal operation, turn the transceiver OFF and press [PTT] + [MR] +  
Power ON again.  
24  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Note:  
To enter the Channel Display Mode, you must have at least one memory channel that  
contains the data.  
If the memory channel contains the Memory name data, the Memory name is displayed in  
place of the “CH” characters.  
You cannot enter Channel Display mode while Key Lock is ON.  
While in the Channel Display mode, only the following keys can be operated.  
[KEY]  
PTT  
SQL  
MONI  
F
MR  
CALL  
LOW  
LAMP  
ENT  
[F] - [KEY]  
MONI  
LAMP  
MR  
[KEY] (1s)  
F
CALL  
While transmitting:  
MONI  
A [F]  
B [VFO]  
C [MR]  
4
D [CALL]  
0
6
1
7
2
8
3
9
5
#
25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SCAN  
Scan is a useful feature for hands-off monitoring of your favorite frequencies.  
Becoming comfortable with all types of Scan will increase your operating  
efficiency.  
This transceiver provides the following type of scans:  
Band Scan  
Scans all frequencies on the current band.  
Scans the specified frequency ranges stored in Memory  
channels L0/U0 ~ L2/U2.  
Program Scan  
Memory Scan  
CALL Scan  
Scans all frequencies stored in the Memory channels.  
Scans the Call channel as well as the currently selected VFO  
frequency or Memory channel.  
Checks the activities on the Priority channel (Pr) every  
3 seconds.  
Priority Scan  
Note:  
When the CTCSS or DCS function is activated, the transceiver stops at a busy frequency  
and decodes the CTCSS tone or DCS code. If the tone or code matches, the transceiver  
unmutes. Otherwise, it resumes scanning.  
Press and hold [MONI] to pause scan in order to monitor the scanning frequency.  
Release [MONI] to resume scanning.  
Pressing [MENU] causes scan to stop.  
If you press any key other than the following keys during scan, the transceiver exits scan  
(excluding Priority Scan): [MONI], [LAMP], [F], [SQL], [F] (1s), or [F] - [LAMP].  
BAND SCAN  
The transceiver scans the entire band of the frequency you selected. For  
example, if you are operating and receiving at 144.525 MHz, it scans all the  
frequencies available for the 2 m band. When the current VFO receiving  
frequency is outside the Program Scan frequency range {page 38}, the  
transceiver scans the entire frequency range available for the current VFO.  
1 Press [VFO].  
2 Rotate the ENC control to select the frequency outside of the Program Scan  
frequency range.  
3 Press [VFO] (1s).  
Scan starts at the current frequency.  
The 1 MHz point blinks while scanning is in progress.  
To change the scan direction, rotate the ENC control clockwise <upward scan> or  
counterclockwise <downward scan>.  
4 To exit Band Scan, press any key other than [MONI], [LAMP], [F], [SQL],  
[F] (1s), or [F] - [LAMP].  
26  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PROGRAM SCAN  
You can limit the scanning frequency range. There are 3 memory channel pairs  
(L0/U0 ~ L2/U2) available for specifying the start and end frequencies. Program  
Scan monitors the range between the start and end frequencies that you have stored  
in these memory channels. Before performing Program Scan, store the Program  
Scan frequency range to one of the memory channel pairs (L0/U0 ~ L2/U2).  
STORING A PROGRAM SCAN FREQUENCY RANGE  
1 Press [VFO], then rotate the ENC control to select your desired start  
frequency.  
2 Press [F] - [MR], then rotate the ENC control to select a memory channel  
from L0 ~ L2.  
3 Press [MR] to store the start frequency in the memory channel.  
4 Rotate the ENC control to select your desired end frequency.  
5 Press [F] - [MR], then rotate the ENC control to select a channel from U0 ~  
U2, corresponding to the channel selected in step 2.  
For example, if you selected L0 in step 3, select U0 for the end frequency.  
6 Press [MR] to store the end frequency in the memory channel.  
USING PROGRAM SCAN  
1 Press [VFO], then rotate the ENC control to select a frequency within the  
frequency range of memory channel L0/U0 ~ L2/U2.  
2 Press [VFO] (1s) to start Program Scan.  
The 1 MHz point blinks while scanning is in progress.  
3 To stop Program Scan, press any key other than [MONI], [LAMP], [F], [SQL],  
[F] (1s), or [F] - [LAMP].  
Note:  
If you press [MONI], Program Scan temporarily pauses. Release [MONI] to resume  
scanning.  
The transceiver stops scanning when it detects a signal.  
If more than 2 Program Scan channel pairs are stored and the frequency range among  
the pairs overlaps, the smaller Program Scan memory channel number has priority.  
To perform Program Scan, the “L” channel frequency must be lower than the “U” channel.  
27  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MEMORY SCAN  
1 Press [MR] (1s).  
Scan starts from the last memory channel number and ascends up through the  
channel numbers (default).  
Rotate the ENC control to change the scanning direction.  
2 To stop Memory Scan, press any key other than [MONI], [LAMP], [F], [SQL],  
[F] (1s), or [F] - [LAMP].  
Note:  
You must have 2 or more memory channels that contain data, excluding special function  
memory channels (L0/U0 ~ L2/U2, and Pr).  
You can perform Memory Scan in Channel Display Mode {page 24}.  
CALL SCAN  
1 Select the frequency (in VFO or Memory Recall Mode) you want to monitor.  
In VFO Mode, rotate the ENC control to select the desired frequency.  
In Memory Recall Mode, rotate the ENC control to select the memory channel you  
want to monitor.  
2 Press [CALL] (1s) to start the Call Scan.  
3 The Call Channel and the selected VFO frequency or memory channel are  
monitored.  
4 To stop Call Scan, press any key other than [MONI], [LAMP], [F], [SQL],  
[F] (1s), or [F] - [LAMP].  
Note:  
The transceiver stops scanning when it detects a signal.  
You can perform Call Scan even if the recalled memory channel has been locked out.  
PRIORITY SCAN  
You may sometimes want to check your favorite frequency activities while  
monitoring other frequencies. In this case, use the Priority Scan function.  
Priority Scan checks the activities of the Priority Channel every 3 seconds. If the  
transceiver detects a signal on the Priority Channel, it recalls the frequency.  
Note: If you do not operate any control or key for 3 seconds after the signal drops, the  
transceiver returns to the original frequency and resumes Priority Scan.  
PROGRAMMING A PRIORITY CHANNEL  
1 Press [VFO], then rotate the ENC control to select your desired Priority  
Channel frequency.  
2 Select CTCSS or DSC, if necessary.  
3 Press [F] - [MR].  
The memory channel number appears and blinks.  
4 Rotate the ENC control to select “Pr”.  
28  
Download from Www.Somanuals.com. All Manuals Search And Download.  
5 Press [MR] to store the data on the Priority Channel.  
USING PRIORITY SCAN  
1 Enter Menu mode and access Menu No. 15 (PR.SCAN), then press [F].  
2 Rotate the ENC control to select “ON”, then press [F] to store the setting.  
3 Press [MENU] or [PTT] to exit Menu mode.  
The “  
” icon appears when the Priority Scan is ON.  
Note:  
If a signal is received on a Priority Channel with a CTCSS or DCS code programmed, the  
Priority Channel is recalled only when the programmed tone/ code matches.  
Press and hold [MONI] to pause Priority Scan when the transceiver is not displaying the  
Priority Channel. Release [MONI] to resume Priority Scan.  
If you clear the Priority Channel, Priority Scan stops.  
You can also press any key other than [MONI], [F], [SQL] (Squelch level adjustment),  
[F] (1s) (Key lock) and [PTT] to exit Priority Scan while “  
” is blinking.  
MEMORY CHANNEL LOCKOUT  
You can lock out memory channels that you prefer not to monitor during Memory  
Scan.  
1 Press [MR] to enter Memory Recall Mode.  
2 Rotate the ENC control to select the memory channel to be locked out.  
3 Enter Menu mode and access Menu No. 13 (L.OUT), then press [F].  
4 Rotate the ENC control to select “ON”, then press [F] to store the setting.  
5 Press [MENU] or [PTT] to exit Menu mode.  
The “  
” icon appears below the memory channel number, indicating the channel  
is locked out.  
Note:  
The Program Scan channels (L0/U0 ~ L2/U2) and Priority Channel (Pr) cannot be locked  
out.  
Even if a memory channel is locked out, you can perform Call Scan between the Call  
Channel and the memory channel.  
29  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SELECTING A SCAN RESUME METHOD  
The transceiver stops scanning at a frequency or Memory channel on which a  
signal is detected. It then continues scanning according to which resume mode  
you have selected. You can choose one of the following modes. The default is  
Time-operated mode.  
The transceiver remains on a busy frequency or  
Time Operated  
mode  
Memory channel for approximately 5 seconds, and  
then continues to scan even if the signal is still  
present.  
TO  
CO  
The transceiver remains on a busy frequency or  
Memory channel until the signal drops out. There is  
a 2 second delay between signal drop-out and scan  
resumption.  
Carrier Operated  
mode  
The transceiver remains on a busy frequency or  
Memory channel even after the signal drops out and  
does not automatically resume scanning.  
SEEK Seek mode  
1 Enter Menu mode and access Menu No. 14 (RESUME), then press [F].  
2 Rotate the ENC control to select a Scan Resume mode from “TO”, “CO” or  
“SEEK”, then press [F] to store the setting.  
3 Press [MENU] or [PTT] to exit Menu mode.  
30  
Download from Www.Somanuals.com. All Manuals Search And Download.  
OPERATING THROUGH REPEATERS  
Repeaters are often installed and maintained by radio clubs, sometimes with the  
cooperation of local businesses involved in the communications industry.  
Compared to simplex communication, you can usually transmit over much greater  
distances by using a repeater. Repeaters are typically located on mountain tops  
or other elevated locations. They generally operate at higher ERP (Effective  
Radiated Power) than a typical station. This combination of elevation and high  
ERP allows communications over considerable distances.  
TX: 144.725 MHz  
TX: 144.725 MHz  
TX tone: 88.5 Hz  
TX tone: 88.5 Hz  
SELECTING AN OFFSET DIRECTION (SHIFT)  
The offset direction allows your transmitting frequency to be higher (+) or  
lower (–) than the receiving frequency.  
Press [SHIFT] to select an offset direction.  
Each time you press [SHIFT], the offset direction changes as follows:  
Simplex operation (no offset) “ ” “ ” Simplex operation (no offset)  
If you are using a TH-K40E (E type) model, the offset direction changes as follows:  
Simplex operation (no offset) “ ” “ ” “  
(–7.6 MHz) Simplex  
operation (no offset)  
If the offset transmit frequency falls outside the allowable range, transmitting is  
inhibited. Use one of the following methods to bring the transmit frequency within  
the band limits:  
Move the receiving frequency further inside the band.  
Change the offset direction.  
Note: While using an odd-split memory channel or transmitting, you cannot change the  
offset direction.  
31  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SELECTING AN OFFSET FREQUENCY  
To access a repeater which requires an odd-split frequency pair, change the  
offset frequency from the default which is used by most repeaters.  
1 Enter Menu mode and access Menu No. 7 (OFFSET).  
2 Rotate the ENC control to select the appropriate offset frequency value.  
The selectable range is from 0.000 MHz to 29.950 MHz, in steps of 50 kHz.  
3 Press [MENU] or [PTT] to exit Menu mode.  
Note: After changing the offset frequency, the new offset frequency will also be used by  
Automatic Repeater Offset.  
TONE FUNCTION  
ACTIVATING THE TONE FUNCTION  
To turn the Tone function on:  
1 Press [TONE] to turn the Tone function On.  
Each time you press [TONE], the selection changes as follows:  
Tone ( ) CTCSS ( ) DCS ( ) Cross Tone ( ) Off (no display).  
The “ ” icon appears on the display when the tone function is On.  
2 Press [T.SEL].  
The current Tone frequency appears on the display and blinks.  
3 Rotate the ENC control to select your desired frequency.  
To exit the tone frequency selection, press [PTT].  
4 Press any key other than [MONI], [LAMP], or [PTT] to set the selected  
frequency.  
Note: If you have set up a Memory channel with a tone setting, simply recall the Memory  
channel instead of setting up the tone frequency every time.  
32  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Available Tone Frequencies  
Tone Frequency (Hz)  
67.0  
69.3  
71.9  
74.4  
77.0  
79.7  
82.5  
85.4  
88.5  
91.5  
94.8  
97.4  
100.0  
123.0  
127.3  
131.8  
136.5  
141.3  
146.2  
151.4  
186.2  
192.8  
203.5  
206.5  
210.7  
218.1  
225.7  
229.1  
233.6  
241.8  
250.3  
254.1  
103.5  
107.2  
110.9  
114.8  
118.8  
156.7  
162.2  
167.9  
173.8  
179.9  
TONE FREQUENCY SCAN  
This function scans through all tone frequencies to identify the incoming tone  
frequency on a received signal. You can use this function to find which tone  
frequency is required by your local repeater.  
1 Press [TONE] to switch the Tone function On.  
Each time you press [TONE], the selection changes as follows:  
Tone ( ) CTCSS ( ) DCS ( ) Cross Tone ( ) Off (no display).  
The “ ” icon appears on the display when the tone function is On.  
2 Press [T.SEL] (1s) to run the Tone Frequency ID scan.  
Scan starts and “T.SCAN” appears on the display.  
While the transceiver is receiving a signal during Tone Frequency Scan, the signal  
is emitted from the speaker.  
When the tone frequency is identified, a beep sounds and the identified frequency  
blinks.  
3 Press [T.SEL] to program the identified frequency in place of the current tone  
frequency.  
If you do not want to program the identified frequency, press any key other than  
[MONI], [LAMP], or [T.SEL].  
33  
Download from Www.Somanuals.com. All Manuals Search And Download.  
AUTOMATIC REPEATER OFFSET  
This function automatically selects an offset direction and activates the Tone  
function, according to the frequency that you have selected. To obtain an up-to-  
date band plan for repeater offset direction, contact your national Amateur Radio  
association.  
1 Enter Menu mode and access Menu No. 8 (ARO).  
2 Rotate the ENC control to select “ON”.  
3 Press [F] to store the setting.  
4 Press [MENU] or [PTT] to exit Menu mode.  
TH-K20A K type:  
TH-K20E (E type):  
Under 145.100 MHz  
No offset  
– offset  
No offset  
+ offset  
No offset  
– offset  
+ offset  
No offset  
– offset  
No offset  
Under 145.600 MHz  
145.600 ~ 145.795 MHz  
145.800 MHz and higher  
No offset  
– offset  
No offset  
145.100 ~ 145.495 MHz  
145.500 ~ 145.995 MHz  
146.000 ~ 146.395 MHz  
146.400 ~ 146.595 MHz  
146.600 ~ 146.995 MHz  
147.000 ~ 147.395 MHz  
147.400 ~ 147.595 MHz  
147.600 ~ 147.995 MHz  
148.000 MHz and higher  
Note: Even when setting the TH-K20A/ TH-K40A M type and TH-K40E (E type) model to  
“ON”, the ARO function will not operate.  
REVERSE FUNCTION  
After setting a separate receive and transmit frequency, you can exchange these  
frequencies using the Reverse function. This allows you to manually check the  
strength of signals you receive directly from other stations, while using a repeater.  
If the station’s signal is strong, move to a simplex frequency to continue the  
contact and free up the repeater.  
Press [REV] to turn the Reverse function ON or OFF.  
When the Reverse function is ON, the “ ” icon will appear on the display.  
34  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Note:  
If the transmit frequency is outside the allowable transmit frequency range when using  
Reverse, pressing [PTT] will cause an error tone to sound and transmitting will be inhibited.  
If the receiving frequency is outside the receiving frequency range when using Reverse,  
an error tone will sound and Reverse will not operate.  
The ARO (Automatic Repeater Offset) will not function when Reverse is ON.  
You cannot switch Reverse ON or OFF while transmitting.  
TRANSMITTING A 1750 Hz TONE  
Most repeaters in Europe require that a transceiver transmit a 1750 Hz tone. On  
the E type model, simply pressing [PF] causes it to transmit a 1750 Hz tone. It is  
also possible to program [1750] on the front panel as a [PF] key for transmitting a  
1750 Hz tone.  
Note: The transceiver continuously transmits a 1750 Hz tone until you release the [PF] key  
(1750).  
Some repeaters in Europe must receive continuous signals for a certain period of  
time, following a 1750 Hz tone. This transceiver is also capable of remaining in  
the transmit mode for 2 seconds after transmitting a 1750 Hz tone.  
1 Enter Menu mode and access Menu No. 33 (1750.HD), then press [F].  
2 Rotate the ENC control to select “ON”, then press [F] to store the setting.  
3 Press [MENU] or [PTT] to exit Menu mode.  
Note: While remaining in the transmit mode, the transceiver does not continuously transmit a  
1750 Hz tone.  
35  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SIGNALING  
CTCSS  
You may sometimes want to hear calls only from specific persons. The  
Continuous Tone Coded Squelch System (CTCSS) allows you to ignore (not  
hear) unwanted calls from other persons who are using the same frequency. To  
do so, select the same CTCSS tone as selected by the other persons in your  
group. A CTCSS tone is subaudible and is selectable from among 42 tone  
frequencies.  
Available CTCSS Frequencies  
CTCSS Frequency (Hz)  
67.0  
69.3  
71.9  
74.4  
77.0  
79.7  
82.5  
85.4  
88.5  
91.5  
94.8  
97.4  
100.0  
103.5  
107.2  
110.9  
114.8  
118.8  
123.0  
127.3  
131.8  
136.5  
141.3  
146.2  
151.4  
156.7  
162.2  
167.9  
173.8  
179.9  
186.2  
192.8  
203.5  
206.5  
210.7  
218.1  
225.7  
229.1  
233.6  
241.8  
250.3  
254.1  
Note: CTCSS does not cause your conversation to be private. It only relieves you from  
listening to unwanted conversations.  
USING CTCSS  
1 Press [TONE] 2 times to turn the CTCSS function ON.  
Each time you press [TONE], the selection changes as follows:  
Tone ( ) CTCSS ( ) DCS ( ) Cross Tone ( ) Off (no display).  
The “ ” icon appears when the CTCSS function is ON.  
2 Press [T.SEL].  
The current CTCSS frequency appears on the display and blinks.  
3 Rotate the ENC control to select your desired frequency.  
To exit the CTCSS frequency selection, press [PTT].  
4 Press any key other than [MONI], [LAMP], or [PTT] to set the selected  
frequency.  
5 When you are called: The transceiver squelch opens only when the selected  
CTCSS tone is received.  
When you make a call: Press and hold [PTT], then speak into the  
microphone.  
36  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CTCSS FREQUENCY SCAN  
This function scans through all CTCSS frequencies to identify the incoming  
CTCSS frequency on a received signal. You can use this function to find which  
CTCSS frequency is used by your group.  
1 Press [TONE] 2 times to turn the CTCSS function ON.  
Each time you press [TONE], the selection changes as follows:  
Tone ( ) CTCSS ( ) DCS ( ) Cross Tone ( ) Off (no display).  
The “ ” icon appears when the CTCSS function is ON.  
2 Press [T.SEL] (1s) to run the CTCSS Frequency scan.  
Scan starts and “CT.SCAN” appears on the display.  
When the CTCSS frequency is identified, a beep sounds and the identified  
frequency blinks.  
3 Press [T.SEL] to program the identified frequency in place of the current tone  
frequency.  
If you do not want to program the identified frequency, press any key other than  
[MONI], [LAMP], or [T.SEL].  
DCS  
Digital Coded Squelch (DCS) is another application which allows you to ignore  
(not hear) unwanted calls. It functions the same way as CTCSS. The only  
differences are the encode/ decode method and the number of selectable codes.  
For DCS, you can select from 104 different codes.  
Available DCS Codes  
DCS Code  
023 025 026 031 032 036 043 047 051 053 054 065 071 072 073  
074 114 115 116 122 125 131 132 134 143 145 152 155 156 162  
165 172 174 205 212 223 225 226 243 244 245 246 251 252 255  
261 263 265 266 271 274 306 311 315 325 331 332 343 346 351  
356 364 365 371 411 412 413 423 431 432 445 446 452 454 455  
462 464 465 466 503 506 516 523 526 532 546 565 606 612 624  
627 631 632 654 662 664 703 712 723 731 732 734 743 754  
Note: DCS does not cause your conversation to be private. It only relieves you from  
listening to unwanted conversations.  
37  
Download from Www.Somanuals.com. All Manuals Search And Download.  
USING DCS  
1 Press [TONE] 3 times to activate the DCS function.  
Each time you press [TONE], the selection changes as follows:  
Tone ( ) CTCSS ( ) DCS ( ) Cross Tone ( ) Off (no display).  
The “ ” icon appears when the DCS function is ON.  
2 Press [T.SEL].  
The current DCS code appears on the display and blinks.  
3 Rotate the ENC control to select your desired code.  
To exit the DCS code selection, press [PTT].  
4 Press any key other than [MONI], [LAMP], or [PTT] to set the selected  
frequency.  
5 When you are called: The transceiver squelch opens only when the selected  
DCS code is received.  
When you make a call: Press and hold [PTT], then speak into the  
microphone.  
DCS CODE SCAN  
This function scans through all DCS codes to identify the incoming DCS code on  
a received signal. You may find it useful when you cannot recall the DCS code  
that the other persons in your group are using.  
1 Press [TONE] 3 times to activate the DCS function.  
Each time you press [TONE], the selection changes as follows:  
Tone ( ) CTCSS ( ) DCS ( ) Cross Tone ( ) Off (no display).  
The “ ” icon appears when the DCS function is ON.  
2 Press [T.SEL] (1s) to run the DCS Code scan.  
Scan starts and “DCS.SCN” appears on the display.  
When a DCS code is identified, the identified code appears on the display and  
blinks.  
3 Press [T.SEL] to program the identified code in place of the currently set DCS  
code.  
If you do not want to program the identified code, press any key other than [MONI],  
[LAMP], or [T.SEL].  
38  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CROSS TONE  
You can set separate signaling types by TX and RX for when you access a  
repeater that uses different encode/ decode signaling.  
1 Press [TONE] 4 times to activate the Cross Tone function.  
Each time you press [TONE], the selection changes as follows:  
Tone ( ) CTCSS ( ) DCS ( ) Cross Tone ( ) Off (no display).  
The “ ” icon appears when the Cross Tone function is ON.  
2 Press [T.SEL].  
The Cross Tone setting appears on the display.  
3 Rotate the ENC control to select your desired Cross Tone setting.  
Setting  
DCS/–  
T/DCS  
DCS/CT  
T/CT  
TX  
RX  
off  
Icon <TX> Icon <RX>  
DCS  
Tone  
DCS  
Tone  
DCS  
CTCSS  
CTCSS  
To exit the Cross Tone selection, press [PTT].  
4 Press any key other than [MONI], [LAMP], or [PTT] to set the selected setting.  
39  
Download from Www.Somanuals.com. All Manuals Search And Download.  
DTMF FUNCTIONS  
This transceiver provides you with 16 dedicated DTMF memory channels. You  
can store a DTMF code (16 digits max.) in each of these channels to recall later  
for speed dialing.  
MANUAL DIALING  
The numeric keypad functions as a DTMF keypad; the 12 keys found on a touch-  
tone phone plus 4 additional keys (A, B, C, D) on the right most column.  
To perform Manual Dialing, follow the steps below.  
1 Press and hold [PTT] to transmit.  
2 While transmitting, press the keys in sequence on the keypad, to send the  
DTMF tones.  
The corresponding DTMF tones are transmitted and monitored through the speaker.  
Frequency (Hz)  
1209  
1366  
1477  
1633  
A
B
C
D
697  
770  
852  
941  
1
4
7
2
5
8
0
3
6
9
#
When DTMF TX Hold is ON, you do not need to continuously press [PTT] to remain  
in Transmit Mode. However, Transmit Mode is retained for only 2 seconds after  
pressing a key, so if the next key is not pressed within this time limit, the transceiver  
stops transmitting.  
AUTOMATIC DIALER  
If you use the 16 dedicated memory channels to store DTMF codes, you do not  
need to remember a long string of digits.  
STORING A DTMF CODE IN MEMORY  
1 Enter Menu mode and access Menu No. 28 (DTMF.MR), then press [F].  
2 Rotate the ENC control to select your desired DTMF memory channel number  
from 0 to F.  
3 Press [F].  
The DTMF code entry display appears and the last digit blinks.  
4 Rotate the ENC control to select a DTMF code.  
40  
Download from Www.Somanuals.com. All Manuals Search And Download.  
You can move the cursor to the left or right by pressing [VFO] or [MR].  
Press [CALL] to delete the character at the current cursor position.  
On the transceiver display, DTMF code “ ” is represented by “E” and “#” is  
represented by “F”.  
When a space is entered, it becomes a “Pause” code.  
5 Press [F] to select the DTMF code and move the cursor to the next digit.  
6 Repeat steps 4 and 5 to enter up to 16 digits.  
7 To complete the entry, press [F] without selecting a DTMF code.  
8 Press [MENU] or [PTT] to exit Menu mode.  
TRANSMITTING A STORED DTMF CODE  
1 While pressing and holding [PTT], press [MONI].  
2 Release [MONI] (continue pressing [PTT]), then rotate the ENC control to  
select the desired DTMF memory channel number (d0 ~ dF).  
3 While still holding [PTT], press [MONI] again to transmit the selected DTMF  
tones.  
The code stored in the channel scrolls across the display, accompanied by DTMF  
tones from the speaker.  
After transmitting, the frequency display is restored.  
If you do not need to confirm the memory channel contents, press [STEP] (0) ~  
[PF] (9), [F] (A) ~ [CALL] (D), [LAMP] ( ) (E), and [ENT] (#) (F) instead of turning  
the ENC control in step 2, to select a channel number. The stored DTMF code will  
be immediately transmitted. (You do not need to press [MONI] in step 3.)  
Note: If you select an empty DTMF memory channel and press [MONI], the frequency  
display is restored.  
ADJUSTING THE DTMF CODE TRANSMIT SPEED  
Some repeaters may not respond correctly if a DTMF code is transmitted at fast  
speed. If this happens, change the DTMF code transmit speed; the default is  
100 ms.  
1 Enter Menu mode and access Menu No. 29 (DT.SPD), then press [F].  
2 Rotate the ENC control to select 50/ 100/ 150 ms, then press [F] to store the  
setting.  
3 Press [MENU] or [PTT] to exit Menu mode.  
41  
Download from Www.Somanuals.com. All Manuals Search And Download.  
DTMF TX HOLD  
This function causes the transceiver to remain in transmit mode for 2 seconds  
after you release each key. Therefore, you can release [PTT] while sending  
DTMF tones through manual dialing.  
1 Enter Menu mode and access Menu No. 30 (DT.HOLD), then press [F].  
2 Rotate the ENC control to select “ON”, then press [F] to store the setting.  
3 Press [MENU] or [PTT] to exit Menu mode.  
ADJUSTING THE PAUSE DURATION  
You can change the pause duration (a space digit) stored in memory channels.  
The default setting is 500 milliseconds.  
1 Enter Menu mode and access Menu No. 31 (DT.PAUS), then press [F].  
2 Rotate the ENC control to select 100/ 250/ 500/ 750/ 1000/ 1500/ 2000 ms,  
then press [F] to store the setting.  
3 Press [MENU] or [PTT] to exit Menu mode.  
DTMF LOCK  
If you have a transceiver with the optional speaker microphone installed and are  
carrying it in the holder or bag, you sometimes may want to disable the keypad  
to avoid accidental transmitting DTMF codes. In this case, turn the DTMF Lock  
function ON.  
1 Enter Menu mode and access Menu No. 32 (DT.LOCK), then press [F].  
2 Rotate the ENC control to select “ON”, then press [F] to store the setting.  
3 Press [MENU] or [PTT] to exit Menu mode.  
42  
Download from Www.Somanuals.com. All Manuals Search And Download.  
AUXILIARY FUNCTIONS  
PROGRAMMABLE VFO  
If you want to limit the operating frequencies within a certain range, program the lower  
and upper frequency limits to the programmable VFO parameters. For example, if  
you select 144 MHz for the lower limit and 145 MHz for the upper limit, the tunable  
range will be limited from 144.000 MHz to 145.995 MHz.  
1 Press [VFO].  
2 Enter Menu mode and access Menu No. 6 (P.VFO), then press [F].  
The current programmable frequency range for the band appears.  
The lower limit frequency blinks.  
3 Rotate the ENC control to select the lower limit frequency in MHz.  
4 Press [F] to store the lower limit frequency.  
The upper limit frequency blinks.  
5 Rotate the ENC control to select the upper limit frequency in MHz.  
6 Press [F] to store the upper limit frequency.  
7 Press [MENU] or [PTT] to exit Menu mode.  
Note:  
You cannot program the 100 kHz or lower digits.  
The upper limit frequency cannot be set lower than the selected lower limit frequency.  
43  
Download from Www.Somanuals.com. All Manuals Search And Download.  
FREQUENCY STEP SIZE  
Choosing the correct frequency step size is essential in order to select your exact  
receive frequency using the ENC control. You can select your desired frequency  
step size from: 5, 6.25, 10, 12.5, 15, 20, 25, 30, 50, or 100 (kHz).  
To change the frequency step size:  
1 Press [STEP].  
The current frequency step size appears.  
2 Rotate the ENC control to select your desired frequency step size.  
3 Press any key other than [MONI], [LAMP], or [PTT] to set the selected  
frequency step size.  
Note: If you change to a frequency step size that does not match the current operating frequency,  
the transceiver automatically adjusts the frequency to match the new frequency step size.  
TONE ALERT  
Tone Alert provides an audible alarm when signals are received on the frequency  
you are monitoring. In addition, it shows the number of hours and minutes  
elapsed after signals have been received. If you use Tone Alert with CTCSS  
or DCS, it sounds only when a received CTCSS tone or DCS code matches the  
tone or code you selected. Turning this function ON is convenient for when you  
are not sitting in front of the transceiver, as confirmation of the receipt is possible  
while away from the transceiver.  
1 Select your desired frequency or memory channel.  
2 Press [ ].  
The OFF/ ON setting appears on the display.  
When Tone Alert is set to ON, the “  
” icon appears on the display.  
When the signal is received for more than 1 second, an alarm sounds, the “  
icon blinks and the elapsed time appears on the display.  
Press [PTT] while the “  
” icon is blinking to turn the Tone Alert function OFF.  
When 9 hours and 59 minutes pass after a signal has been received, counting  
stops.  
Each time a new signal is received, the elapsed time resets to 0:00.  
44  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Note:  
While Tone Alert is ON, there is no speaker output when a signal is received. To monitor  
the signal, press and hold [MONI].  
When Tone Alert is ON, APO does not turn the power OFF.  
If you switch the transceiver OFF while the “  
back up the elapsed time.  
” icon is blinking, the transceiver does not  
When Tone Alert is ON, you can use only the following keys: [ ], [MONI], [SQL], and  
[LAMP].  
POWER ON MESSAGE  
You can change the Power ON Message (a maximum of 6 characters) when the  
transceiver is turned ON.  
1 Enter Menu mode and access Menu No. 1 (P.ON.MSG), then press [F].  
A blinking cursor appears.  
2 Rotate the ENC control to select a character.  
You can enter the following alphanumeric characters:  
0 ~ 9, A ~ Z, – (hyphen), / (slash) and a space.  
3 Press [MR].  
The cursor will move to the next digit.  
You can move the cursor to the left or right by pressing [VFO] or [MR].  
Press [CALL] to delete the character at the current cursor position.  
4 Repeat steps 3 and 4 to enter up to 6 digits.  
Press [CALL] to delete the character at the current cursor position.  
5 Press [F] to store the message.  
6 Press [MENU] or [PTT] to exit Menu mode.  
Note: If the Power ON Message is deleted, “TH-K20” or “TH-K40” is displayed.  
45  
Download from Www.Somanuals.com. All Manuals Search And Download.  
BEEP FUNCTION  
The Beep function provides confirmation of entry, error status, and malfunctions  
of the transceiver. We recommend you leave this function ON in order to detect  
erroneous operations and malfunctions.  
However, to turn the beep function OFF:  
1 Enter Menu mode and access Menu No. 2 (BEEP), then press [F].  
2 Rotate the ENC control to select “OFF”, then press [F] to store the setting.  
3 Press [MENU] or [PTT] to exit Menu mode.  
The transceiver generates the following warning beeps even if the beep function is  
turned OFF.  
• APO warning beeps  
• Time-Out Timer warning beep  
Note: The beep output level is linked to the volume control position.  
LOCK TYPE  
You can select your desired Lock type. “KEY” locks the operational keys, “FRQ”  
locks the frequencies so that you do not accidentally change them and  
“KEY.FRQ” locks both the keys and the frequencies.  
Manual DTMF and Autodial can still be performed while either lock is active.  
1 Enter Menu mode and access Menu No. 3 (LOCK), then press [F].  
2 Rotate the ENC control to select “KEY”, “FRQ” or “KEY.FRQ”, then press [F] to  
store the setting.  
3 Press [MENU] or [PTT] to exit Menu mode.  
“KEY”: Only the following keys & controls can be operated.  
PWR/VOL control  
MONI SQL LAMP  
“FRQ”: Only the following keys can be operated.  
ENC control  
PTT  
F
PWR/VOL control  
LOW SQL T.SEL  
PTT  
MONI  
PF  
F
MENU  
TONE  
LAMP  
You can still use the ENC control in menu mode.  
46  
Download from Www.Somanuals.com. All Manuals Search And Download.  
“KEY.FRQ”: Only the following keys can be operated.  
PWR/VOL control PTT MONI  
F
SQL  
LAMP  
BATTERY SAVER  
The Battery Saver extends the operating time of the transceiver. It automatically  
activates when the squelch is closed and no key is pressed for more than 10 seconds.  
To reduce battery consumption, this function shuts the receiver circuit OFF for the  
programmed time, then momentarily turn it back ON to detect a signal.  
To program the receiver shut-off period for the battery saver:  
1 Enter Menu mode and access Menu No. 4 (SAVE), then press [F].  
2 Rotate the ENC control to select OFF/ 0.2/ 0.4/ 0.6/ 0.8/ 1.0/ 2.0/ 3.0/ 4.0/  
5.0 seconds, then press [F] to store the setting.  
3 Press [MENU] or [PTT] to exit Menu mode.  
Note:  
The longer the shut-off period, the more you can save on battery consumption. However,  
there is a greater chance of missing a signal.  
When the CTCSS/ DCS code matches while receiving, the battery saver function is turned  
OFF.  
Battery Saver does not function while scanning.  
While the Battery Saver is operating, the TX-RX LED may flash green when receiving a  
CTCSS/DCS signal which does not match the transceiver CTCSS/DCS setting.  
47  
Download from Www.Somanuals.com. All Manuals Search And Download.  
APO (AUTO POWER OFF)  
The transceiver switches OFF automatically if no keys or controls are pressed or  
adjusted for 30 minutes (default). One minute before the transceiver switches  
OFF, warning beeps sound for a few seconds and “APO” blinks. You can select  
the APO time from OFF (disable), 30 (default), 60, 90, 120, or 180 minutes.  
1 Enter Menu mode and access Menu No. 5 (APO), then press [F].  
2 Rotate the ENC control to select OFF/ 30/ 60/ 90/ 120/ 180 minutes, then  
press [F] to store the setting.  
3 Press [MENU] or [PTT] to exit Menu mode.  
Note:  
APO does not function while the transceiver is scanning.  
When Tone Alert is ON, APO does not turn the power OFF.  
The APO timer starts counting down the time when no keys are pressed and no controls  
are adjusted.  
The APO warning beep sounds and “APO” appears 1 minute before the transceiver turns  
OFF.  
NARROW BAND FM OPERATION  
The transceiver operates in normal FM deviation (±5 kHz) mode for both  
transmitting and receiving. You can also operate the transceiver in narrow band  
FM deviation (±2.5 kHz) mode.  
1 Enter Menu mode and access Menu No. 9 (N.FM), then press [F].  
2 Rotate the ENC control to select “ON”, then press [F] to store the setting.  
3 Press [MENU] or [PTT] to exit Menu mode.  
When FM narrow is activated, the “ ” icon appear on the display.  
48  
Download from Www.Somanuals.com. All Manuals Search And Download.  
BEAT SHIFT  
Since the transceiver uses a microprocessor to control various functions of the  
transceiver, the CPU clock oscillator’s harmonics or image may appear on some  
spots of the receive frequencies. In this case, turn the Beat Shift function ON.  
1 Enter Menu mode and access Menu No. 10 (B.SHIFT), then press [F].  
2 Rotate the ENC control to select “ON”, then press [F] to store the setting.  
3 Press [MENU] or [PTT] to exit Menu mode.  
Note: Beat Shift status can be stored to each Memory channel.  
VOX (VOICE-OPERATED TRANSMIT)  
VOX eliminates the necessity of manually switching to Transmit mode each  
time you want to transmit. The transceiver automatically switches to Transmit  
mode when the VOX circuitry senses that you have begun speaking into the  
microphone. When you operate the VOX function, you must use an optional  
Headset; the internal speaker and microphone are too close to each other to be  
used for the VOX function.  
To turn the VOX function ON:  
1 Enter Menu mode and access Menu No. 16 (VOX), then press [F].  
2 Rotate the ENC control to select the desired VOX gain level from 1 (least  
sensitive) to 9 (most sensitive), then press [F] to store the setting.  
3 Press [MENU] or [PTT] to exit Menu mode.  
When VOX is activated, the “  
” icon appear on the display.  
Note:  
While in Menu mode, the VOX function is temporarily disabled.  
Since the VOX circuit must detect the presence of your voice, you may notice a slight  
delay in transmitting; the very first part of your message may not be transmitted.  
VOX cannot be used with an optional Speaker/ Microphone.  
49  
Download from Www.Somanuals.com. All Manuals Search And Download.  
VOX GAIN  
To enjoy the VOX function, take the time to properly adjust the VOX Gain level.  
This level controls the VOX circuit to detect the presence or absence of your  
voice.  
There are 2 ways to adjust the VOX Gain.  
While the VOX function is ON:  
1 Speak into the headset microphone using your normal tone of voice to  
transmit.  
If transmitting does not begin, readjust the VOX Gain so that the transceiver  
transmits while you are speaking. To readjust the gain, press and hold [PTT] then  
rotate the ENC control to select a more sensitive gain level.  
While readjusting the gain, you can release [PTT]. The transceiver will remain in  
Adjustment Mode for approximately 5 seconds.  
2 Adjust the VOX Gain by rotating the ENC control until the transceiver reliably  
switches to transmit mode each time you speak.  
From the Menu:  
1 Enter Menu mode and access Menu No. 16 (VOX), then press [F].  
2 Rotate the ENC control to select the desired VOX gain level from 1 (least  
sensitive) to 9 (most sensitive), then press [F] to store the setting.  
3 Press [MENU] or [PTT] to exit Menu mode.  
VOX ON BUSY  
You can configure the transceiver to force VOX to transmit even if the transceiver  
is receiving a signal.  
1 Enter Menu mode and access Menu No. 17 (VOX.BSY), then press [F].  
2 Rotate the ENC control to select “ON”, then press [F] to store the setting.  
3 Press [MENU] or [PTT] to exit Menu mode.  
Note: You can press [PTT] or [PF] (if 1750 Hz is programmed) to transmit, regardless of the  
setting in Menu No. 17.  
VOX DELAY TIME  
If the transceiver returns to receive mode too quickly after you stop speaking, the  
end of your signal may not be transmitted. To avoid this, select an appropriate  
delay time that allows your entire signal to be transmitted, before Transmit mode  
ends. However, do not make the delay overly long.  
1 Enter Menu mode and access Menu No. 18 (VOX.DLY), then press [F].  
50  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2 Rotate the ENC control to select the desired delay time to 250/ 500 (default)/  
750/ 1000/ 1500/ 2000/ 3000 ms, then press [F] to store the setting.  
3 Press [MENU] or [PTT] to exit Menu mode.  
Note:  
If you press [PTT] while the VOX function is ON, the VOX Delay Time is not reflected to  
the transmitted signal.  
If you press [PF] (if 1750 Hz is programmed) to transmit a 1750 Hz tone, the VOX Delay  
Time is not reflected.  
If the DCS function is ON, the transceiver remains in Transmit mode for the duration set  
by the VOX Delay Time. It then sends a Turn-Off Code to close the receiving party’s  
squelch.  
TIME-OUT TIMER  
The Time-out Timer limits the duration you transmit. Just before the transceiver  
stops the transmitting, a warning beep sounds. This function is necessary to protect  
the transceiver from thermal damage and can therefore not be turned OFF.  
1 Enter Menu mode and access Menu No. 19 (TOT), then press [F].  
2 Rotate the ENC control to select the desired time from 0.5/ 1.0/ 1.5/ 2.0/ 2.5/  
3.0/ 3.5/ 4.0/ 4.5/ 5.0/10.0 (default) minutes, then press [F] to store the setting.  
3 Press [MENU] or [PTT] to exit Menu mode.  
Note: A warning beep sounds even if you set Menu No. 2 (BEEP) to OFF.  
BUSY CHANNEL LOCKOUT  
This function is used in order to prevent transmitting on a channel or frequency that  
somebody else is currently using. When turned ON, an error beep sounds and you  
cannot transmit even if you press [PTT].  
1 Enter Menu mode and access Menu No. 20 (BCL), then press [F].  
2 Rotate the ENC control to select “ON”, then press [F] to store the setting.  
3 Press [MENU] or [PTT] to exit Menu mode.  
51  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TX INHIBIT  
You can inhibit transmitting to prevent unauthorized individuals from transmitting, or  
to eliminate accidentally transmitting while carrying the transceiver.  
1 Enter Menu mode and access Menu No. 21 (TX.INH), then press [F].  
2 Rotate the ENC control to select “ON”, then press [F] to store the setting.  
3 Press [MENU] or [PTT] to exit Menu mode.  
MICROPHONE SENSITIVITY  
You can select a Microphone Sensitivity level from Low, Medium (default), or  
High.  
1 Enter Menu mode and access Menu No. 22 (M.SENS), then press [F].  
2 Rotate the ENC control to select the desired Sensitivity level, then press [F] to  
store the setting.  
3 Press [MENU] or [PTT] to exit Menu mode.  
PROGRAMMABLE FUNCTION KEYS  
TRANSCEIVER PF KEY  
This is the [PF] (Programmable Function) key on the transceiver front panel. You  
can assign your desired function to this key.  
1 Enter Menu mode and access Menu No. 23 (PF KEY), then press [F].  
2 Rotate the ENC control to select your desired function for the key, then press  
[F] to store the setting.  
Programmable functions available are:  
M.DISP (Memory display type)/ 1750/ WX <TH-K20A K type only>/ N.FM/  
PR.SCAN (Priority scan).  
Default setting: TH-K20A K type: WX, TH-K20A/ TH-K40A M type: M.DISP  
TH-K20E/ TH-K40E (E type): 1750  
3 Press [MENU] or [PTT] to exit Menu mode.  
52  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MICROPHONE PF KEYS  
There are 3 microphone PF (Programmable Function) keys: [PF1], [PF2], and  
[PF3]. You can assign your desired functions to these 3 keys.  
1 Enter Menu mode and access Menu No. 24 (PF 1) and/or Menu No. 25 (PF 2)  
and/or Menu No. 26 (PF 3), then press [F].  
2 Rotate the ENC control to select your desired function for the key, then press  
[F] to store the setting.  
Programmable functions available are:  
VFO/ MR/ CALL/ UP/DOWN/ TONE/ T.SEL/ SHIFT/ REV/ 1750/ WX <TH-  
K20A K type only>/ N.FM/ PR.SCAN (Priority scan)/ M.DISP (Memory display  
type)/ SQL/ LOW/ STEP/ L.OUT (Memory channel lockout)/ MONI/ LAMP  
3 Press [MENU] or [PTT] to exit Menu mode.  
MICROPHONE KEY LOCK  
The Microphone Key Lock function will lock the microphone PF keys.  
1 Enter Menu mode and access Menu No. 27 (MIC.LK), then press [F].  
2 Rotate the ENC control to select “ON”, then press [F] to store the setting.  
3 Press [MENU] or [PTT] to exit Menu mode.  
BATTERY TYPE  
Set the battery type to match the type of batteries you are using in the transceiver.  
If the battery type is not set properly, the battery indicator will not display the  
correct battery power while transmitting.  
1 Enter Menu mode and access Menu No. 34 (BATT), then press [F].  
2 Rotate the ENC control to select the Battery Type to “LI-ION” (Lithium ion  
battery) or “ALKALI” (Alkaline dry battery), then press [F] to store the setting.  
3 Press [MENU] or [PTT] to exit Menu mode.  
53  
Download from Www.Somanuals.com. All Manuals Search And Download.  
WEATHER ALERT (TH-K20A K TYPE ONLY)  
Weather Alert is available only in the USA and Canada. When activated,  
this function will check for a received NOAA 1050 Hz tone. When the tone is  
received, the weather alert tone will sound.  
WEATHER ALERT ON/ OFF  
1 Enter Menu mode and access Menu No. 35 (WX.ALT), then press [F].  
2 Rotate the ENC control to select “ON”, then press [F] to store the setting.  
3 Press [MENU] or [PTT] to exit Menu mode.  
When activated, the “  
” icon appears on the display.  
” icon blinks.  
When a signal is being received, the “  
WEATHER CHANNEL  
Whether or not Weather Alert is activated, you can still access the weather  
channels.  
While recalling the Call channel, you cannot change to the Weather channel.  
1 Press the key programmed with the [WX] function.  
2 Rotate the ENC control to select your desired channel.  
MR.  
Name. No.  
CH  
Freq.  
(MHz)  
MR.  
Name  
CH  
No.  
Freq.  
(MHz)  
Location  
Location  
NOAA  
NOAA/  
Canada  
WX 1  
WX 2  
WX 3  
A1  
A2  
A3  
162.550  
162.400  
162.475  
WX 6  
WX 7  
WX 8  
A6  
A7  
A8  
162.500  
162.525  
161.650  
NOAA/  
Canada  
NOAA  
NOAA/  
Canada  
Canada  
WX 4  
WX 5  
A4  
A5  
162.425  
162.450  
NOAA  
NOAA  
WX 9  
A9  
A0  
161.775  
163.275  
Canada  
WX 10  
WEATHER CHANNEL SCAN  
The memory channel only for the weather alert is scanned.  
Press and hold the key programmed with the [WX] function to start the weather  
channel scan.  
Scanning stops when the channel with the highest signal level is received.  
Memory scanning stops when performing any operation other than [LAMP], [MONI],  
[Key Lock] ([F] (1s)), and ENC control.  
54  
Download from Www.Somanuals.com. All Manuals Search And Download.  
APPENDIX  
OPTIONAL ACCESSORIES  
The following options are available for use with this transceiver:  
KNB-63L: Li-ion battery pack  
KNB-65L: Li-ion battery pack  
HMC-3: Headset  
KHS-21: Headset  
BT-16:  
Battery case  
KHS-29F: Headset  
KBH-18: Belt clip  
EMC-3: Clip microphone  
EMC-7: Clip microphone  
EMC-11: Clip microphone  
PG-4Y: PC connection cable  
KVC-22: DC vehicular charger adapter  
KSC-35S: Rapid charger  
SMC-32: Speaker microphone  
SMC-33: Speaker microphone  
SMC-34: Speaker microphone  
MCP-5A: Memory Control Program  
(free software)  
Note: Optional accessories for use with this transceiver may change, post-production. (New  
options may become available and/or current options may be discontinued.) Please refer to  
the options catalog(s) for applicable transceivers.  
To download the MCP-5A software, go to:  
Note: This URL may change without notice.  
MAINTENANCE  
GENERAL INFORMATION: This product has been factory aligned and tested  
to specification before shipment. Attempting service or alignment without factory  
authorization can void the product warranty.  
SERVICE: When returning this product for repair, send the complete product, packed  
in its original box and packing material, to the authorized KENWOOD dealer from whom  
you purchased it, or any authorized KENWOOD service center. Include a full description  
of the problem(s) experienced. Include your telephone number along with your name and  
address in case the service technician needs to contact you. If available, also include  
your fax number and e-mail address. Do not return accessory items unless you feel they  
are directly related to the problem. A copy of the service report will be returned with the  
product.  
SERVICE NOTE: If you desire to correspond on a technical or operational  
problem, please make your note legible, short, complete, and to the point. Help us  
help you by providing the following:  
Model and serial number of equipment  
Question or problem you are having  
Other equipment in your station pertaining to the problem  
ATTENTION: Do not pack the equipment in crushed newspapers for shipment! Extensive  
damage may result during rough handling or shipping.  
55  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Note:  
Record the date of purchase, serial number and dealer from whom this product was  
purchased.  
For your own information, retain a written record of any maintenance performed on this  
product.  
When claiming warranty service, please include a photocopy of the bill of sale or other  
proof-of-purchase showing the date of sale.  
CLEANING: To clean the case of this product, use a neutral detergent (no strong  
chemicals) and a damp cloth.  
TROUBLESHOOTING  
The problems described in this table are commonly encountered operational  
malfunctions and are usually not caused by circuit failure.  
Problem  
Solution  
Nothing appears on the display when  
the transceiver is switched ON, or the  
display is blinking ON and OFF.  
The battery pack is discharged. Recharge  
the battery pack or replace the batteries.  
Transceiver Lock function is ON (the “  
icon is visible). Press [F] (1s) to turn OFF  
Transceiver Lock.  
Most keys and the Selector do not  
function.  
The transceiver is in Channel Display Mode.  
Press [PTT] + [MR] + Power ON to exit  
Channel Display Mode.  
The Tone Alert function is ON. Turn OFF the  
Tone Alert function.  
You have stored no data in any of the  
memory channels. Store the desired  
frequencies in the memory channels.  
You cannot recall any memory  
channel.  
The current frequency step size does not  
allow the frequency to be selected. Select  
an appropriate frequency step size. Press  
[STEP] to change the frequency step size.  
You cannot select the exact desired  
frequency using the selector.  
Programmable VFO frequency range is too  
narrow. Expand the frequency range in Menu  
No. 6 (P.VFO).  
The selective call function (CTCSS or DCS)  
is ON. Turn OFF the selective call function.  
Increasing the Volume control does  
not allow you to hear audio.  
The Tone Alert function is ON. Turn OFF the  
Tone Alert function.  
56  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Problem  
Solution  
You selected a frequency outside the  
allowable range. Select a frequency within  
the allowable transmit frequency range.  
You selected a transmit offset that places the  
transmit frequency outside the limit. Select a  
proper offset direction or offset frequency.  
You cannot transmit by pressing  
[PTT].  
Busy Chnnel Lockout is ON. Access Menu  
No.20 (BCL) and select “OFF”.  
TX inhibit is ON. Access Menu No.21  
(TX.INH) and select “OFF”.  
The battery pack voltage is too low to  
transmit. Change or replace the battery.  
Wrong tone frequency is selected. Select a  
proper repeater access tone.  
Repeater cannot be accessed.  
Wrong offset direction is selected. Try other  
offset directions.  
DTMF Lock is ON. Access Menu No. 32  
(DT.LOCK) and select “OFF”.  
DTMF tone cannot be transmitted.  
The transmit time exceeded the programmed  
TOT time. Access Menu No. 19 (TOT) to  
select your desired transmit length. The  
TOT cannot be turned OFF; it protects the  
transceiver from thermal damage.  
The transceiver returns to Receive  
Mode after transmitting for a long  
time.  
You have selected “SEEK” for Menu  
No. 14 (RESUME). Select either “TO”  
(Time-Operated) or “CO” (Carrier-Operated)  
for Menu No. 14 (RESUME).  
The Scan function does not resume  
scanning after the transceiver detects  
a signal.  
OPERATION NOTICES  
The transceiver has been designed and engineered to avoid possible hardware glitches.  
However, you may notice the following symptoms when you operate the transceiver.  
These symptoms are not malfunctions.  
Receiving Signals In Cities: When you receive signals in cities, the receiver’s entire  
antenna indicator may light up without receiving any strong signals. This happens when  
the RF amplifier in the receiver is overloaded by nearby strong interference signals.  
Transmitting: If you continuously transmit for an extended duration at high power, the  
transceiver becomes warm. If you continue or repeatedly transmit before the transceiver  
cools down, the thermal protector gradually decreases the output power to 1 W.  
Internal Beats: On some spots of the frequency, the S meter moves without receiving  
any signals or you cannot receive any signals. This is inevitable when you use super-  
heterodyne receivers. If this happens, access Menu No. 10 (B.SHIFT) and select “ON”.  
However, the following Internal Beat Frequencies cannot be eliminated.  
TH-K20A/E: 152.69375/ 152.695/ 152.7/ 152.705/152.70625/ 153.59375/ 153.595/ 153.6/ 153.605/ 153.60625/  
172.79375/ 172.795/ 172.8/ 172.805/ 172.80625 (MHz)  
TH-K40A/E: 403.19375/ 403.195/ 403.2/ 403.205/ 403.20625/ 422.39375/ 422.395/ 422.4/ 422.405/ 422.40625/  
441.59375/ 441.595/ 441.6/ 441.605/ 441.60625/ 460.79375/ 460.795/ 460.8/ 460.805/ 460.80625 (MHz)  
57  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TRANSCEIVER RESET  
There are 2 types of transceiver resets available:  
Partial Reset  
Use to initialize all settings other than the Memory channels and DTMF memory  
channels.  
Full Reset  
Use to initialize all transceiver settings that you have customized.  
There are 2 ways to perform a reset on the transceiver: by key operation and by  
accessing Menu mode.  
KEY OPERATION  
1 Turn the transceiver power OFF.  
2 Press [F] + Power ON.  
All indicators are lit.  
3 Release [F].  
4 Rotate the ENC control and select your desired reset type: “PA.RST” (Partial  
Reset) or “FL.RST” (Full Reset).  
5 Press [F].  
“SURE ?” appears.  
6 Press [F] again to reset the transceiver.  
Note: When the lock function is on, you cannot reset the transceiver using Key operation.  
MENU OPERATION  
1 Enter Menu mode and access Menu No. 99 (RESET), then press [F].  
2 Rotate the ENC control and select your desired reset type: “PART” (Partial  
Reset) or “FULL” (Full Reset).  
3 Press [F].  
“SURE ?” appears.  
4 Press [F] again to reset the transceiver.  
58  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SPECIFICATIONS  
Note: All specifications are guaranteed within the amateur radio band.  
General  
TH-K20A/E  
TH-K40A/E  
430 ~ 440  
144 ~ 148 (K/M)  
144 ~ 146 (E)  
Guaranteed range (MHz)  
TX & RX  
136 ~ 174 (M)  
144 ~ 148 (K)  
144 ~ 146 (E)  
400 ~ 470 (M)  
430 ~ 440 (E)  
TX  
RX  
Operation Frequency range  
(MHz)  
136 ~ 174  
F3E, F2D  
50 Ω  
400 ~ 470  
Mode  
Antenna impedance  
–20°C ~ +60°C (+4°F ~ +140°F)  
–10°C ~ +60°C (+14°F ~ +140°F)  
<with KNB-63L/ KNB-65L>  
Operating temperature range  
Operating Voltage  
Frequency stability  
DC 6.0 ~ 9.0 V (7.4 V nominal)  
Within ± 2.5 ppm  
Dimensions W x H x D (projections not  
included) <with KNB-63L>  
54 x 111.7 x 25.3 mm  
2.13 x 4.4 x 1.00 in  
Weight <with KNB-63L>  
Approx. 210 g/ 7.4 oz.  
Transmitter  
TH-K20A/E  
5.5 W  
TH-K40A/E  
High  
5 W  
RF output power  
<with KNB-63L/ KNB-65L>  
Medium  
2 W  
Low  
1 W  
Modulation  
Reactance  
Within ±5 kHz  
Less than -60 dB  
Maximum frequency deviation  
Spurious emission  
Modulation distortion  
Less than 5 % (300 Hz ~ 3 kHz)  
2 kΩ  
Microphone impedance  
Receiver  
Circuit type  
TH-K20A/E  
TH-K40A/E  
Double super heterodyne  
1st IF: 38.85 MHz 2nd IF: 450 kHz  
Less than 0.16 μV Less than 0.18 μV  
Less than 0.13 μV  
Intermediate Frequency (IF)  
Sensitivity (12 dB SINAD)  
Squelch sensitivity  
-6 dB  
More than 10 kHz  
Selectivity  
-50 dB  
Less than 28 kHz  
Audio output  
More than 400 mW (8 Ω/ 10 % distortion)  
Specifications are subject to change without notice due to advancements in technology.  
59  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Indesit Washer IWC 6145 S User Manual
Jacuzzi Hot Tub DT10 User Manual
JBL Speaker GTiAutomotive User Manual
Karcher Pressure Washer K 226M User Manual
Kenwood Satellite Radio TS 780 User Manual
Kenwood Speaker KFC P306 User Manual
KitchenAid Dishwasher W10155577B User Manual
Kodak Scanner i1310 User Manual
Konica Minolta Camcorder DiMAGE S414 User Manual
Kramer Electronics Weather Radio TP 202 User Manual