Kentrox Network Router 486 User Manual

®
DataSMART 486 and 488  
E1/FE1 Frame Monitoring DSU/CSUs  
DataSMART E1/FE1  
Frame Monitoring  
DSU/CSUs provide  
comprehensive, easy-  
to-use, end-to-end  
circuit monitoring to  
improve Frame Relay  
network performance.  
E1/FE1 Frame Monitoring  
Provide end-to-end circuit  
monitoring for Frame Relay  
networks  
DSU/CSUs  
n Identify when bandwidth  
With DataSMART Frame Monitoring DSU/CSUs,  
service providers and network managers have the tools  
to deliver reliable, high-performance Frame Relay  
services. Frame Monitoring DSU/CSUs help verify  
Service Level Agreements between the PTT and  
customer, match bandwidth to application needs, and  
isolate performance problems to the LAN, the WAN, or  
the local loop.  
adjustments are needed  
n Isolate the source of slow  
network performance: the  
LAN, local loop, or WAN  
n G.704 performance monitoring  
for E1 services  
n X.21/V.35 data port available  
DataSMART DSU/CSUs maximize your network  
uptime with convenient management features, such as  
in-band access for simplified remote management.  
Each DSU/CSU includes an integrated Ethernet port and  
a front-panel LCD for easy local management, along with  
standards-based SNMP management.  
for a variety of equipment  
n Add/drop voice port available  
for voice and data traffic  
integration  
n Standards-based, in-band  
management with SNMP  
DataSMART E1/FE1 Frame Monitoring DSU/CSUs,  
teamed with FrameVision Reporter software, deliver the  
tools and information necessary to ensure ongoing  
savings – and a quick return on investment.  
n Easy local management with  
10Base-T access and  
front-panel LCD  
n Free DataSMART® Installer  
and Alarms Utility software  
n 5-year manufacturer’s  
warranty ensures reliability  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Specifications  
E1/FE1 Frame Monitoring DSU/CSUs  
NETWORK INTERFACE  
Line Rate E1 (2048 Kbps) + 50 ppm  
Framing G.704  
ALARMS  
Traps  
LOCAL LOOP  
PERFORMANCE MONITORING  
Data Storage  
SNMP Traps via SLIP/PPP, Ethernet or  
in-band  
ASCII  
Transmitted out async control port  
Last 24 hours of data in 15 minute  
increments; last 7 days of data in  
24-hour increments  
Line Code HDB3  
Protocol Clear Channel  
Frame Relay  
Line Impedance  
FRAME RELAY CIRCUIT MANAGEMENT  
Methodology  
Monitors Network and terminal interface  
Non-intrusive, in-band  
Reports  
Based on G.821 for performance  
Far end  
Alarm history  
Network interface statistical  
Terminal interface statistical  
(add/drop only)  
120+ 10at 1024 KHz  
Virtual Circuit (VC) Traffic  
75+ 10at 1024 KHz  
Group Measurements: % bandwidth  
utilization, kbps, delays, VC status  
(24 hour)  
Detail: Frames, octets, kbps, delay  
measurements, VC status  
Mechanical  
DA15 socket for 120Ω  
Adapter for 75BNC  
Lightning Protection  
120interface withstands lightning  
surges defined per FCC Part 68, and  
unit recovers  
VC Status  
DIAGNOSTICS  
Up, down, BECN set, FECN set, DE set,  
bandwidth utilization threshold exceeded,  
delay threshold exceeded  
LEDs  
Power/fail  
E1  
Data port transmit  
Data port receive  
Data port CTS  
Data port RTS  
TERMINAL INTERFACE (DataSMART 488)  
Line Rate E1 (2048 Kbps) + 50 ppm  
Framing G.704  
Line Code HDB3  
Protocol Clear Channel (DS0)  
VCTraffic Detail Measurement Intervals  
Current/previous second; cur/prev 15  
min; cur/prev 2 hour; cur 24 hour;  
previous 7 complete days, 12 2-hour  
intervals for current day  
LoopTests  
Line Impedance  
VC Delay Measurements  
Local loopback  
Data terminal loopback  
Terminal interface loopback  
(add/drop only)  
120+ 10at 1024 KHz  
Maximum observed delay, average delay,  
attempts made, measurement packets  
lost Automatic delay measurements for  
up to 64 active VCs  
75+ 10at 1024 KHz  
Mechanical  
DA15 socket for 120Ω  
Adapter for 75BNC  
STANDARDS  
VC Delay Diagnostics  
DATA PORT INTERFACE  
EN60590  
EN55022 Class B  
EN50081-2  
ITU G.703, G.704, G.821  
BABT NTR4, CTR 12, CTR 13  
Round-trip VC delay via in-band  
Frame Relay PerformanceThresholds  
User configurable  
Bit Rate  
Nx64 kbps (N=1...31)  
Electrical V.35 compatible  
X.21 via adapter  
Access bandwidth utilization  
Round-trip delay  
V.11/X.27/EIA-530  
Mechanical  
REGULATORY (Call for current status)  
Frame Relay Statistics  
Non-integral number of octets  
Invalid header address  
DB25 socket  
ACN  
Australian Communications Authority and  
Spectrum Management  
NTR 4  
MANAGEMENT  
Control Ports  
BABT  
CE  
TUV  
Invalid HDLC FCS  
Aborted frames  
FPING responses lost (system total)  
Frame statistical  
Frame group (VC summary)  
Frame individual (VC detail)  
Frame VC utilization  
Burst: data sent above CIR and above  
excess burst rates  
_
_
0682 X  
GS  
DCE and DTE  
EIA-574  
DE9 socket  
Daisy chain  
38.4 kbps maximum  
English menus  
Reports  
ENVIRONMENT  
Operating 0° to 50° C  
5% to 90% RH, non-condensing  
-20° to 66° C  
5% to 65% RH  
Storage  
Async ASCII or SLIP/PPP  
Ethernet Port  
10Base-T RJ45 socket  
Transmit and receive LEDs  
SNMP Agent  
POWER  
AC  
LOCAL LOOP DIAGNOSTICS  
LoopTests  
85-265 VAC, 47-63 Hz, 8W  
PHYSICAL  
Desktop or tray mount  
Dimensions  
Line loopback  
Payload loopback  
MIB II (RFC 1213)  
DS1/E1 MIB (RFC 1406)  
Frame Relay MIB (RFC 1315)  
Enterprise MIB*  
TELNET server  
Responds to Ping  
Security filters  
Usage  
Data port loopback  
LineTest Codes  
19.68 cm W x 4.32 cm H x 29.21 cm D  
1.14 kg (approx.)  
Weight  
223-1, 215-1, QRS, 3-in-24, 1-in-8, All 1s,  
All 0s  
DataTest Codes  
511, 2047  
BERTTester  
Independent BERT on all test codes  
(for IP source addresses)  
Up to 10 SNMP Trap hosts  
In-band  
LCD  
From network or router  
Shared or dedicated VC  
Frame Relay or ATM DXI  
Front panel display of unit status  
Front panel configuration of unit  
Page 3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
DataSMART  
E1/FE1 Frame Monitoring DSU/CSUs  
Ordering Guide  
Description  
Model No.  
72486  
DataSMART 486 E1/FE1  
Frame Monitoring DSU/CSU  
Frame Monitoring DSU/CSUs  
DataSMART 486 E1/FE1  
Frame Monitoring DSU/CSU  
DataSMART 488 E1/FE1 Add/Drop  
Frame Monitoring DSU/CSU  
72488  
Mounting Accessories  
Mounting Tray, 1 Stand-alone unit  
78031  
Management and Reporting Software  
FrameVision Reporter  
DataSMART Installer  
Alarms Utility  
70304  
70305  
70451  
*
1
2
3
4
*Call for availability.  
DataSMART 488 E1/FE1 Add/Drop  
Frame Monitoring DSU/CSU  
2
3
4
1
1
Back Panel & Cable Guide  
To Network andTerminal Equipment  
930xx091 DA15P to DA15S  
1
To Data Equipment  
V.35  
3
930xx101 DA15P to Stub  
95010054 DB25P to MRAC34P, 10 ft. (4 m)  
930xx121 DA15P to RJ48C Modular Plug  
930xx131 DA15P to DA15P  
95010073 DB25P to MRAC34P, tail circuit timing  
(DCE to DCE)  
95001074 DB25P to MRAC34S, 1 ft. (0.4 m)  
77892  
77895  
DA15P to RJ48C Socket Adapter  
78904  
X.21  
DB25P to MRAC34S Adapter  
DA15P to 2 x 75 ohm Socket Coaxial  
Adapter  
960xx009 BNC Plug to BNC Socket  
960xx010 BNC Plug to BNC Plug  
78902  
DB25P to DA15S, X.21 Adapter  
95010061 DB25P to DB25P, 10 ft. (4 m)  
Worldwide Sales Offices  
Corporate  
93005132 DA15P to DA15P, Crossover  
77993003 DA15P to Barrier Strip Adapter  
95010058 DB25P to DB25P, tail circuit timing (DCE  
to DCE)  
Headquarters +1-503-643-1681  
Australia +61-2-9975-1499  
Belgium +32-2-712-6555  
Canada +1-905-629-3104  
China +86-10-65007001  
Germany +49-211-53065530  
Korea +82-2-333-8989  
Latin America +1-310-640-2922  
Singapore +65-227-5621  
United Kingdom +44-1705-481691  
95010066 DB25P to DC37P (EIA-530 to RS449)  
2
To ControlTerminal  
To 10Base-T LAN  
95007077 RJ45 Plug to RJ45 Plug,  
95006022 DE9S to DE9P, 6 ft. (2.4 m)  
95005023 DE9S to DB25P, 5 ft. (2 m)  
93001211 DE9P to RJ48, Cisco 2500 SLIP  
4
Cat. 3 UTP, 7 ft. (2.8 m)  
95007078 RJ45 Plug to RJ45 Plug, Crossover,  
Cat. 3 UTP, 7 ft. (2.8 m)  
To Control Port  
78899  
DE9S to RJ45 Adapter  
78891  
DataSMART Installation Kit  
NOTE: xx denotes length of cable, contact factory  
for available lengths. DA, DB, DC, DE designate the  
size of the shell which encapsulates the cable  
connector.  
ADC Kentrox  
14375 NW Science Park Drive  
P = Plug (male); S = Socket (female).  
Portland, Oregon 97229  
(800) 733-5511  
(503) 643-1681  
FAX (503) 641-3341  
Pre-sales Support (800) 733-5511  
Literature Hotline (800) 232-5879  
Copyright 1998, ADC Kentrox. An Equal Opportunity Employer. DataSMART is a registered trademark and FrameVision is a trademark of  
Kentrox Industries, Inc., dba ADC Kentrox. ADC Kentrox is a registered trademark of ADC Telecommunications, Inc. Thesetrademarks  
areregisteredintheU.S. PatentandTrademark Office and may be registered in other countries. All other trademarks mentioned are the  
propertyoftheirrespectivecompanies. Specificationspublishedherearecurrentorplannedasofthedateofpublication. ADC Kentrox  
reserves the right to change specifications without prior notice. You may verify product specifications by contacting any of our offices.  
8/98 05-04-007  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Ingersoll Rand Heat Pump AD40A X X User Manual
Jacuzzi Washer F4N6036WRL User Manual
Jasco Headphones 86711 User Manual
Johnson Hardware Saw E 16 User Manual
JVC DVD Player XV S60BK User Manual
JVC DVD VCR Combo HR XVC18BUS User Manual
JVC Home Theater System LVT0858 001A User Manual
Kenmore Sewing Machine 385 17630 User Manual
KitchenAid Dishwasher KUDF230B User Manual
Korg Electronic Keyboard KORG 700S User Manual