DataSMART 486 and 488
E1/FE1 Frame Monitoring DSU/CSUs
DataSMART E1/FE1
Frame Monitoring
DSU/CSUs provide
comprehensive, easy-
to-use, end-to-end
circuit monitoring to
improve Frame Relay
network performance.
E1/FE1 Frame Monitoring
Provide end-to-end circuit
monitoring for Frame Relay
networks
DSU/CSUs
n Identify when bandwidth
With DataSMART Frame Monitoring DSU/CSUs,
service providers and network managers have the tools
to deliver reliable, high-performance Frame Relay
services. Frame Monitoring DSU/CSUs help verify
Service Level Agreements between the PTT and
customer, match bandwidth to application needs, and
isolate performance problems to the LAN, the WAN, or
the local loop.
adjustments are needed
n Isolate the source of slow
network performance: the
LAN, local loop, or WAN
n G.704 performance monitoring
for E1 services
n X.21/V.35 data port available
DataSMART DSU/CSUs maximize your network
uptime with convenient management features, such as
in-band access for simplified remote management.
Each DSU/CSU includes an integrated Ethernet port and
a front-panel LCD for easy local management, along with
standards-based SNMP management.
for a variety of equipment
n Add/drop voice port available
for voice and data traffic
integration
n Standards-based, in-band
management with SNMP
DataSMART E1/FE1 Frame Monitoring DSU/CSUs,
teamed with FrameVision Reporter software, deliver the
tools and information necessary to ensure ongoing
savings – and a quick return on investment.
n Easy local management with
10Base-T access and
front-panel LCD
n Free DataSMART® Installer
and Alarms Utility software
n 5-year manufacturer’s
warranty ensures reliability
Download from Www.Somanuals.com. All Manuals Search And Download.
Specifications
E1/FE1 Frame Monitoring DSU/CSUs
NETWORK INTERFACE
Line Rate E1 (2048 Kbps) + 50 ppm
Framing G.704
ALARMS
Traps
LOCAL LOOP
PERFORMANCE MONITORING
Data Storage
SNMP Traps via SLIP/PPP, Ethernet or
in-band
ASCII
Transmitted out async control port
Last 24 hours of data in 15 minute
increments; last 7 days of data in
24-hour increments
Line Code HDB3
Protocol Clear Channel
Frame Relay
Line Impedance
FRAME RELAY CIRCUIT MANAGEMENT
Methodology
Monitors Network and terminal interface
Non-intrusive, in-band
Reports
Based on G.821 for performance
Far end
Alarm history
Network interface statistical
Terminal interface statistical
(add/drop only)
120Ω + 10Ω at 1024 KHz
Virtual Circuit (VC) Traffic
75Ω + 10Ω at 1024 KHz
Group Measurements: % bandwidth
utilization, kbps, delays, VC status
(24 hour)
Detail: Frames, octets, kbps, delay
measurements, VC status
Mechanical
DA15 socket for 120Ω
Adapter for 75Ω BNC
Lightning Protection
120Ω interface withstands lightning
surges defined per FCC Part 68, and
unit recovers
VC Status
DIAGNOSTICS
Up, down, BECN set, FECN set, DE set,
bandwidth utilization threshold exceeded,
delay threshold exceeded
LEDs
Power/fail
E1
Data port transmit
Data port receive
Data port CTS
Data port RTS
TERMINAL INTERFACE (DataSMART 488)
Line Rate E1 (2048 Kbps) + 50 ppm
Framing G.704
Line Code HDB3
Protocol Clear Channel (DS0)
VCTraffic Detail Measurement Intervals
Current/previous second; cur/prev 15
min; cur/prev 2 hour; cur 24 hour;
previous 7 complete days, 12 2-hour
intervals for current day
LoopTests
Line Impedance
VC Delay Measurements
Local loopback
Data terminal loopback
Terminal interface loopback
(add/drop only)
120Ω + 10Ω at 1024 KHz
Maximum observed delay, average delay,
attempts made, measurement packets
lost Automatic delay measurements for
up to 64 active VCs
75Ω + 10Ω at 1024 KHz
Mechanical
DA15 socket for 120Ω
Adapter for 75Ω BNC
STANDARDS
VC Delay Diagnostics
DATA PORT INTERFACE
EN60590
EN55022 Class B
EN50081-2
ITU G.703, G.704, G.821
BABT NTR4, CTR 12, CTR 13
Round-trip VC delay via in-band
Frame Relay PerformanceThresholds
User configurable
Bit Rate
Nx64 kbps (N=1...31)
Electrical V.35 compatible
X.21 via adapter
Access bandwidth utilization
Round-trip delay
V.11/X.27/EIA-530
Mechanical
REGULATORY (Call for current status)
Frame Relay Statistics
Non-integral number of octets
Invalid header address
DB25 socket
ACN
Australian Communications Authority and
Spectrum Management
NTR 4
MANAGEMENT
Control Ports
BABT
CE
TUV
Invalid HDLC FCS
Aborted frames
FPING responses lost (system total)
Frame statistical
Frame group (VC summary)
Frame individual (VC detail)
Frame VC utilization
Burst: data sent above CIR and above
excess burst rates
_
_
0682 X
GS
DCE and DTE
EIA-574
DE9 socket
Daisy chain
38.4 kbps maximum
English menus
Reports
ENVIRONMENT
Operating 0° to 50° C
5% to 90% RH, non-condensing
-20° to 66° C
5% to 65% RH
Storage
Async ASCII or SLIP/PPP
Ethernet Port
10Base-T RJ45 socket
Transmit and receive LEDs
SNMP Agent
POWER
AC
LOCAL LOOP DIAGNOSTICS
LoopTests
85-265 VAC, 47-63 Hz, 8W
PHYSICAL
Desktop or tray mount
Dimensions
Line loopback
Payload loopback
MIB II (RFC 1213)
DS1/E1 MIB (RFC 1406)
Frame Relay MIB (RFC 1315)
Enterprise MIB*
TELNET server
Responds to Ping
Security filters
Usage
Data port loopback
LineTest Codes
19.68 cm W x 4.32 cm H x 29.21 cm D
1.14 kg (approx.)
Weight
223-1, 215-1, QRS, 3-in-24, 1-in-8, All 1s,
All 0s
DataTest Codes
511, 2047
BERTTester
Independent BERT on all test codes
(for IP source addresses)
Up to 10 SNMP Trap hosts
In-band
LCD
From network or router
Shared or dedicated VC
Frame Relay or ATM DXI
Front panel display of unit status
Front panel configuration of unit
Page 3
Download from Www.Somanuals.com. All Manuals Search And Download.
DataSMART
E1/FE1 Frame Monitoring DSU/CSUs
Ordering Guide
Description
Model No.
72486
DataSMART 486 E1/FE1
Frame Monitoring DSU/CSU
Frame Monitoring DSU/CSUs
DataSMART 486 E1/FE1
Frame Monitoring DSU/CSU
DataSMART 488 E1/FE1 Add/Drop
Frame Monitoring DSU/CSU
72488
Mounting Accessories
Mounting Tray, 1 Stand-alone unit
78031
Management and Reporting Software
FrameVision Reporter
DataSMART Installer
Alarms Utility
70304
70305
70451
*
1
2
3
4
*Call for availability.
DataSMART 488 E1/FE1 Add/Drop
Frame Monitoring DSU/CSU
2
3
4
1
1
Back Panel & Cable Guide
To Network andTerminal Equipment
930xx091 DA15P to DA15S
1
To Data Equipment
V.35
3
930xx101 DA15P to Stub
95010054 DB25P to MRAC34P, 10 ft. (4 m)
930xx121 DA15P to RJ48C Modular Plug
930xx131 DA15P to DA15P
95010073 DB25P to MRAC34P, tail circuit timing
(DCE to DCE)
95001074 DB25P to MRAC34S, 1 ft. (0.4 m)
77892
77895
DA15P to RJ48C Socket Adapter
78904
X.21
DB25P to MRAC34S Adapter
DA15P to 2 x 75 ohm Socket Coaxial
Adapter
960xx009 BNC Plug to BNC Socket
960xx010 BNC Plug to BNC Plug
78902
DB25P to DA15S, X.21 Adapter
95010061 DB25P to DB25P, 10 ft. (4 m)
Worldwide Sales Offices
Corporate
93005132 DA15P to DA15P, Crossover
77993003 DA15P to Barrier Strip Adapter
95010058 DB25P to DB25P, tail circuit timing (DCE
to DCE)
Headquarters +1-503-643-1681
Australia +61-2-9975-1499
Belgium +32-2-712-6555
Canada +1-905-629-3104
China +86-10-65007001
Germany +49-211-53065530
Korea +82-2-333-8989
Latin America +1-310-640-2922
Singapore +65-227-5621
United Kingdom +44-1705-481691
95010066 DB25P to DC37P (EIA-530 to RS449)
2
To ControlTerminal
To 10Base-T LAN
95007077 RJ45 Plug to RJ45 Plug,
95006022 DE9S to DE9P, 6 ft. (2.4 m)
95005023 DE9S to DB25P, 5 ft. (2 m)
93001211 DE9P to RJ48, Cisco 2500 SLIP
4
Cat. 3 UTP, 7 ft. (2.8 m)
95007078 RJ45 Plug to RJ45 Plug, Crossover,
Cat. 3 UTP, 7 ft. (2.8 m)
To Control Port
78899
DE9S to RJ45 Adapter
78891
DataSMART Installation Kit
NOTE: xx denotes length of cable, contact factory
for available lengths. DA, DB, DC, DE designate the
size of the shell which encapsulates the cable
connector.
ADC Kentrox
14375 NW Science Park Drive
P = Plug (male); S = Socket (female).
Portland, Oregon 97229
(800) 733-5511
(503) 643-1681
FAX (503) 641-3341
E-mail [email protected]
Pre-sales Support (800) 733-5511
Literature Hotline (800) 232-5879
Copyright 1998, ADC Kentrox. An Equal Opportunity Employer. DataSMART is a registered trademark and FrameVision is a trademark of
Kentrox Industries, Inc., dba ADC Kentrox. ADC Kentrox is a registered trademark of ADC Telecommunications, Inc. Thesetrademarks
areregisteredintheU.S. PatentandTrademark Office and may be registered in other countries. All other trademarks mentioned are the
propertyoftheirrespectivecompanies. Specificationspublishedherearecurrentorplannedasofthedateofpublication. ADC Kentrox
reserves the right to change specifications without prior notice. You may verify product specifications by contacting any of our offices.
8/98 05-04-007
Download from Www.Somanuals.com. All Manuals Search And Download.
|