Range Hood
Use & Care Guide
Installation Manual
Models
31130 (30” wide - Stainless)
31133 (36” wide - Stainless)
HB0108
09030 rev. A
SEARS CANADA INC., Toronto, Ontario M5B 2B8
Download from Www.Somanuals.com. All Manuals Search And Download.
OPERATION
OPERATION
Always turn ON your hood before you begin cooking in order
to establish an air flow in the kitchen. Let the blower run for a
few minutes to clear the air after you turn off the range. This
will help keep the whole kitchen cleaner and brighter.
Nigthlight switch
Press this switch once to turn on the nightlight. Press this switch
once more to shut off the nightlight.
CLEANING
HC0027
Grease filters
1
2
3
4
5
The grease filters should be cleaned frequently. Use a warm
detergent solution. Grease filters are dishwasher safe.
1. Blower Delay switch
2. ON/OFF Blower speed switches
3. Halogen lights switch
4. Filter maintenance indicator
5. Nightlight switch
Wash more often if your cooking style generates greater grease
- like frying foods or wok cooking.
Delay OFF switch
Remove filters by pulling latch tabs and rotating filters
downward.
When a speed is selected, press the Delay OFF switch to
activate the delay function. The corresponding speed indicator
LED will start flashing to indicate this function is activated.
The fan will continue to operate for 5 minutes and will stop
automatically. To cancel the delay function, press the Delay
OFF switch once again; the blower will then work in normal
mode.
Hood Cleaning
Stainless steel cleaning: How to maintain its “BRIGHT LOOK”
Do:
-
Regularly wash surfaces with clean cloth or rag soaked with
warm water and mild soap or liquid dish detergent.
NOTE: The blower speed can be increased or decreased during
Delay mode without starting another 5-minute cycle.
-
-
Always clean in the direction of original polish lines.
Always rinse well with clear water (2 or 3 times) after cleaning.
Wipe dry completely.
ON/OFF Blower speed switches
Press the switch corresponding to the desired blower speed.
The light over the switch indicates the selected speed (from 1
for low speed to 4 for high speed). To turn off the blower, press
once more on the corresponding blower speed switch.
-
You may also use a specialized household stainless steel
cleaner.
Don’t:
HEAT SENTRY™
-
Do not use any steel or stainless steel wool or any other
scrapers to remove stubborn dirt.
Do not use any harsh or abrasive cleaners.
Do not allow dirt to accumulate.
Your hood is equipped with a HEAT SENTRY thermostat. This
thermostat is a device that will turn on or speed up the blower if
it senses excessive heat above the cooking surface. The light
indicator over speed 3 switch will quickly flash.
-
-
-
Do not let plaster dust or any other construction residues
reach the hood. During construction/renovation, cover the
hood to make sure no dust sticks to stainless steel surface.
1) If blower is OFF - it turns blower ON to speed 3.
2) If blower is ON at a lower (or higher) speed setting - it turns
blower to speed 3.
Avoid: when choosing a detergent
When the temperature level drops to normal, the blower will
return to its original setting and the light indicator over speed 3
switch will stop flashing.
-
-
-
Any cleaners that contains bleach will attack stainless
steel.
Any products containing: chloride, fluoride, iodide, bromide
will deteriorate surfaces rapidly.
WARNING:The HEAT SENTRY thermostat can
start the blower even if the hood is turned OFF.
When this occurs, press the speed 3 switch
until its light indicator stops flashing if you
must stop the blower.
Any combustible products used for cleaning such as
acetone, alcohol, ether, benzol, etc., are highly explosive
and should not be used close to a range.
Halogen lights switch
This switch provides 3 different lighting levels, according to
your needs. The lighting intensity changes by increments of 1
(i.e.: press once for low intensity, once again to get more, up
to three times). From the higher intensity, press once again to
shut off the lights.
Uses 120 Volts, 50 W, MR 16 with GU10 base or PAR 16 with
GU10 base, shielded halogen bulbs (included).
WARNING: In order to prevent the risk of
personal injury, do not install a lamp identified
for use only in enclosed fixtures.
Filter maintenance indicator
After 24 hours of operation, the filter maintenance light indicator
will start blinking. This indicates the filters need to be cleaned
in order to maintain efficient operation of the unit. The indicator
light will blink until the function is reset by pressing the nightlight
switch for 3 seconds.
3
Download from Www.Somanuals.com. All Manuals Search And Download.
PARTS INCLUDED WITH HOOD
PARTS INCLUDED WITH HOOD
Aluminum grease filters
(2 per hood)
HR0010
Parts Bag including:
5 no. 8 x 1½” countersunk screws
8 no. 8 x 3/4” screws
6 no. 8 x 3/8” screws
6 Drywall anchors
3 Washers
HR0051
Decorative flue assembly
(lower and upper flues)
120 V, 50 W, PAR16 with GU10 base
shielded halogen lamp
(2 per hood)
Sears Part No. V05921
HR0012
3¼” x 10” adapter/damper
(for horizontal discharge)
HR0011
HR0044
8” round adapter/damper
(for vertical discharge), in a
separate box
HR0041
HR0042
PARTS NOT INCLUDED WITH HOOD
Hood mounting bracket
Ducting Accessories
(See “Range Hood System” on page 5 for Ducting Accessory
Model Nos.)
Upper flue mounting bracket
Optional flue extension for 10-ft. ceilings (model no. 31131)
HR0043
TOOLS NEEDED FOR HOOD INSTALLATION
Screwdriver
(Robertson or Phillips)
Tape
Measure
Wire
Stripper
Pencil
Sabre
Saw
Keyhole
Saw
-or-
Duct Tape
Drill
4
Download from Www.Somanuals.com. All Manuals Search And Download.
RANGE HOOD SYSTEM
Broan Model
Broan Model 639
3¼” x 10”
Standard Wall Cap
634 or 644
Broan Model 643
8” Round Wall Cap
Roof Cap
Wall & Roof Caps
8” Round
Adjustable Elbow
Elbow
Upper
Decorative
Flue
Broan Model 401
Standard
3¼” x 10” Duct
Ductwork
8” Round
Standard Duct
Adapter/damper
8” round (supplied
with hood)
Lower
Decorative
Flue
Adapter/damper
3¼” x 10” (supplied
with hood)
For vertical discharge
For horizontal discharge
Adapter/dampers
31130 or 31133
Range Hood
HL0142
Single Blower
(supplied with hood)
5
Download from Www.Somanuals.com. All Manuals Search And Download.
EQUIVALENT DUCT LENGTH CHART
Kenmore range hoods are designed to perform efficiently when attached to long runs of duct. As a point of reference, this hood
will function at approximately 80% of its rated air performance when 300 equivalent feet of 8” round ductwork is attached. Use
this chart to calculate the equivalent duct length of your system. Note that 8” round is the minimum recommended duct size.
HR0047
Straight Duct
HR0048
8-in. round x 2-ft. long
Equivalent length
Broan Model 643
2 ft.
8-in. Round Wall Cap
Equivalent length
30 ft.
(15-ft. w/o damper)
HR0045
Broan Model 401
Straight Duct
3¼” x 10” x 1 ft. long
Equivalent length
HR0049
4 ft.
Broan Model 634 or 644
8-in. Round Roof Cap
Equivalent length
30 ft. (7-ft. w/o damper)
HR0046
8-in. Round Elbow
Equivalent length
10 ft.
HR0050
Broan Model 639
3¼” x 10”Wall Cap
Equivalent length
90 ft.
(14-ft. w/o damper)
6
Download from Www.Somanuals.com. All Manuals Search And Download.
SELECT INSTALLATION TYPE
1. Plan where and how the ductwork will be installed.
Install proper-sized ductwork, transition(s), elbow(s), and
roof or wall cap.
For best results, use a minimum number of transition and
elbows.
ROOF CAP
8” ROUND DUCT
2. The minimum hood distance above cooktop must not be
less than 24’’. A maximum of 30’’above cooktop is highly
recommended for best capture of cooking impurities.
DECORATIVE
FLUE
Distances over 30” are at the installer and users discretion;
providing that ceiling height and decorative flue length
permit.
WALL
CAP
HOOD
NOTE
There are 2 different heights for the horizontal ductwork.
Refer to page 8 for more details.
3¼” 10”
X
DUCT
REFER TO CHART
FOR DISTANCE ABOVE
COOKING SURFACE
CEILING
HEIGHT
MINIMUM HOOD DISTANCE ABOVE COOKTOP
HH0134A
8 FEET
9 FEET
24”
29½”
25”
10 FEET
*10-ft. ceilings require flue extension model no. 31131
(sold separately).
Refer to illustrations below to locate duct opening according to discharge type chosen (grey parts to be installed later).
VERTICAL DISCHARGE
HORIZONTAL DISCHARGE
C
L
C
L
30” WIDTH HOOD
36” WIDTH HOOD
1415⁄16”
1715⁄16”
25⁄16”
43⁄16”
81⁄16”
8” DIA.
33⁄16”
12¾”
9¾”
OR
1415⁄16”
1715⁄16”
30” WIDTH HOOD
36” WIDTH HOOD
HK0117A
HK0122A
7
Download from Www.Somanuals.com. All Manuals Search And Download.
WIRING INSTALLATION
WARNING: Improper grounding can result in a risk of electric shock. Consult a qualified electrician
if the grounding instructions are not completely understood, or if doubt exists as to whether the
appliance is properly grounded. Do not use an extension cord. If the power supply cord is too short,
have a qualified electrician install an outlet near the appliance, in accordance with all applicable codes
and standards.Turn off electrical power at service entrance before wiring.
GROUNDING INSTRUCTIONS
This appliance must be grounded. In the event of an electrical short circuit, grounding reduces the risk of electric shock by providing
an escape wire for the electric current. This appliance is equipped with a cord having a grounding wire with a grounding plug.
The plug must be plugged into an outlet that is properly installed and grounded.
Position the outlet within the space covered by the decorative
flue. Place the outlet at a maximum distance of 24” (from where
the cord exits from the hood). The center of the outlet must be
positioned at 2¾” from the center of the future hood location
(as illustrated beside). Make sure this does not interfere with
a mounting bracket fastening area or with the decorative flue
(where the flue touches the wall).
HE0106A
CAUTION: The BLUE wires are for a make-up
air device option (not available in Canada). Never
remove the caps on the BLUE wires end.
!
HE0107
8
Download from Www.Somanuals.com. All Manuals Search And Download.
PREPARE THE HOOD
1. Lay the hood on its back on a table.
3
Remove grease filters by lifting the metal latch tab (1),
pushing down on the filter (2) and tilting is towards you (3).
1
NOTE
Use a piece of cardboard to avoid damaging the table or the
hood.
2
HD0376
2. Choose the opening:
RETAINING SCREWS LOCATIONS
VERTICAL DISCHARGE:
Using a Robertson or a Phillips no. 2 screwdriver, remove
the 4 top metal plate retaining screws in order to clear the
vertical discharge opening (see illustration beside). Discard
the metal plate and its screws.
HO0142
1
2
HORIZONTAL DISCHARGE:
OR
OR
In order to ease a retrofit installation, the horizontal discharge
may be positioned on higher OR on lower back of the hood.
From outside the unit, remove the knockout for the chosen
discharge opening (see illustrations beside).
HR0038
9
Download from Www.Somanuals.com. All Manuals Search And Download.
PREPARE THE HOOD
NOTE
The following instructions are for the horizontal installation only. For a vertical installation, go to the “Install the hood” section on
page 11.
These Kenmore Elite Series range hoods are factory shipped with the blower mounted for a vertical discharge configuration. For
a horizontal discharge configuration, disassemble the blower from the inner top of the hood (see illustrations below). It will be
assembled to the inner back of the hood once the hood is mounted on the wall.
3. Uplug the blower.
HE0085
RIGHT SIDE
MOUNTING SCREW
LOCATION
LEFT SIDE MOUNTING
SCREW LOCATION
4. Using a 5/16” socket, or a Robertson or a Phillips no. 2
screwdriver, remove all blower mounting screws from
the inner top of the hood. Set aside the blower and its
screws.
HD0386
HD0385
NOTE
If this hood replaces another one, please note that the location of the air exhaust can vary from one manufacturer to another. In
order to ease a retrofit installation, the horizontal discharge may be positioned on higher OR on lower back of the hood.
1
2
5. According to your needs, the adapter/damper can
be installed to the higer or lower back discharge
using the upper screw holes on each side of the
adapter/damper. See illustrations beside.
HJ0040
6. Secure the adapter/damper to the back of the hood using 2 no. 8 x 3/8” screws (included). Seal the adapter/damper to the
hood using metal foil duct tape.
NOTE
The wall ducting must be properly prepared to receive the adapter. Before performing the installation, make sure the adapter
fits easily in the duct.
10
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALL THE HOOD
WARNING:When cutting or drilling into wall,
do not damage electrical wiring and other
hidden utilities.
1. Construct wood wall framing that is flush with surface of wall
studs.
Wood wall framing must be at least 1/2” thick and 3” high.
Ensure to assemble wood wall framing to wall studs for a
solid installation.
Ensure the height of the framing will allow the mounting
bracket to be secured to the framing within the dimensions
shown (see illustration beside).
After wall surface is finished, carefully center and level the
hood mounting bracket over installation location. Secure it
to wall framing using 3 no. 8 x 1½” screws.
Using a level, draw a vertical line up to the ceiling starting
from the mounting bracket center.
HD0374A
36¾” = BOTTOM OF HOOD 24” ABOVE COOKTOP
42¾” = BOTTOM OF HOOD 30” ABOVE COOKTOP
2. Center the upper flue mounting bracket with the center line
previously drawn and place it flush with the ceiling.
Use the upper flue mounting bracket as a template to mark
the position of its screws.
CEILING
Drill the 3 screw holes using a 3/16” drill bit.
Insert the included drywall anchors into the drilled holes
(1 per hole).
Secure the upper flue bracket to the wall using 3 no. 8 x 3/4”
screws.
C
MOUNTING BRACKET
FLUSH WITH CEILING
HD0377
L
SCREW LOCATIONS
Ensure that the bracket is tight against the wall.
WARNING: BE CAREFUL when installing the decorative flue and hood, they may have sharp edges.
CAUTION: DO NOT REMOVE the protective plastic film covering the decorative flue (upper & lower).
!
!
UPPER HOLES LOCATION
3. Align the hood and center it above the hood mounting
bracket. Gently lower the hood until it securely engages the
bracket.
Level the hood.
With the hood hanging in place, secure it to the wall through
both holes located in the inside upper back of hood using
2 no. 8 x 1½” screws.
Drill through both holes located in the inside lower back
of hood using a 3/16” drill bit. Insert the included drywall
anchors into the drilled holes (one for each hole). Secure
the hood to the wall using 2 no. 8 x 3/4” screws and
2 washers.
BACK OF THE HOOD
SIDE VIEW
Ø 3/16” TYP.
LOWER HOLES LOCATION
HD0380A
HORIZONTAL DISCHARGE ONLY:
A
B
4. Position the blower on the higher (A) or lower (B) back wall
discharge as determined previously.
Using a 5/16” socket, or a Robertson or a Phillips no. 2
screwdriver and the 4 previously removed screws, secure
the blower to the hood.
NOTE
RIGHT SIDE
MOUNTING
SCREW
In order to ease installation, before mounting the blower,
prepare the screw holes by screwing all 4 screws without
the blower, then remove and mount the blower.
LOCATION
HD0387
5. Plug the blower back in and plug hood power cord into the
outlet.
11
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALL THE HOOD
INSTALL THE HOOD
VERTICAL DISCHARGE ONLY:
VERTICAL DISCHARGE ONLY:
6. Mount the 8” round adapter/damper (included in a separate
box) to the hood using 4 no. 8 x 3/8” sheet metal screws
(included).
7. Plug hood power cord into the outlet.
Slide a 8” metal round duct over the adapter/damper. Use
metal foil duct tape to seal the joint.
HJ0037
HJ0041
FINALIZE THE INSTALLATION
UPPER FLUE
TOP CORNERS
1. Remove protective plastic film covering the lower flue
only.
Peel off both corners at the top of the upper flue.
Position the lower flue rear notches down (the ones with the
45° angle).
Gently slide upper flue inside lower flue, louvers end first
(so that louvers are hidden inside lower flue, as they are not
needed).
LOUVERS
NOTE
Both lower and upper flues are included with the hood, but
for a 10 foot ceiling, discard the provided upper flue and
use the optional extension flue, part no. 31131 (purchase
separately).
LOWER FLUE
REAR NOTCH
HO0144
LOWER FLUE
REAR NOTCH
2. Carefully slide in place decorative flue base (notches end
first) between the shaded part and the exterior wall of the
top of the hood.
HO0143
12
Download from Www.Somanuals.com. All Manuals Search And Download.
FINALIZE THE INSTALLATION
UPPER FLUE MOUNTING BRACKET
FRONT VIEW
3. Slide up the upper flue until it is aligned with its mounting
bracket. The bracket must be inside the flue. Secure
the upper flue to its bracket using 2 no. 8 x 3/8” screws
(included). See illustration beside.
UPPER
FLUE
NOTE
Duct not shown in illustration to ease understanding.
4. Remove protective plastic film covering the upper flue.
HO0140
INSTALLING GREASE FILTERS
Rest rear filters edge on filter springs (A) in the range hood.
Using metal latch tab, tilt up the filters into position. Make sure
filter tabs (B) are securely engaged in range hood front edge
after installation.
A
B
HD0393
CHANGING LIGHT BULBS
WARNING: In order to prevent the risk of personal injury, do not install a lamp identified for use only in enclosed
fixtures.
!
This range hood must use 2 shielded halogen lamps (120 V, 50 W PAR16 with GU10 base), included.
Refer to page 4 for ordering information.
WARNING: In order to prevent the risk of personal injury, the halogen lamps must cool down before removing
!
them.
1. To remove lamps, gently push upwards and turn
1
2
3
counterclockwise to disengage bulb leads from their
grooves.
NOTE
If need be, use a rubber dishwashing glove to add grip when
removing the bulb.
2. Install the new lamps by placing the bulb leads into their
grooves in the socket.
HO0089
3. Gently push upwards and turn clockwise until secure.
13
Download from Www.Somanuals.com. All Manuals Search And Download.
SERVICE PARTS
QTY. (HOOD WIDTH)
1
KEY NO. PART NO.
DESCRIPTION
30”
1
36”
1
1
2
3
18504
18494
18496
UPPER FLUE MOUNTING BRACKET
UPPER DECORATIVE FLUE
1
1
2
LOWER DECORATIVE FLUE
1
1
COVER PLATE FOR 8” ROUND
TOP EXHAUST
4
5
18515
18522
1
1
1
1
ELECTRONIC CONTROL MODULE
(INCLUDING OVERLAY, ITEM 6)
6
7
07322
05917
OVERLAY
1
2
1
2
SOCKET (GU10)
3
SOCKET HOLDER (LEFT
AND RIGHT GU10 PLASTIC)
8
9
16154
16172
2
2
2
2
18
LIGHT TRIM (PLASTIC PAINTED
GREY FOR GU10)
17
4
6
SHIELDED HALOGEN LAMP
(120V, 50W, GU10)
16
10
11
12
13
14
05921
09022
08582
08783
18523
2
1
1
1
1
2
1
1
1
1
5
TRANSFORMER
INTERNAL BLOWER
(INCLUDING CAPACITOR)
CAPACITOR
MICROMESH FILTERS
13.83” X 13.83” (SET OF 2)
15
7
15
16
17
18
09035
09014
08543
13296
KENMORE ELITE LOGO
1
1
1
1
1
1
1
1
12
8
HOOD MOUNTING BRACKET
8” ROUND A DAPTER/DAMPER
3¼” X 10” ADAPTER/DAMPER
9
13
14
11
10
KENMORE ELITE
INSTALLATION GUIDE
*
09030
1
1
PARTS BAG: 5 NO. 8 X 1½”
COUNTERSUNK SCREWS,
8 NO. 8 X 3/4” SCREWS,
6 NO. 8 X 3/8” SCREWS,
6 DRYWALL ANCHORS,
3 WASHERS
HL0143
*
09027
1
1
ORDER REPLACEMENT PARTS BY PART NO. - NOT BY KEY NO.
*NOT ILLUSTRATED.