K5500 Vacuum Manual7/24 7/29/02 11:33 AM Page 1
Model K 5500
Part No. 1.195-107.0
Vacuum Cleaner Operator Manual
Contents
K 5500 model overview . . . . . . . . . . . . . . 1-2
Filter performance . . . . . . . . . . . . . . . . . . . .2
Safety Instructions . . . . . . . . . . . . . . . . . . .3
Assembling and operating the cleaner
Preparation . . . . . . . . . . . . . . . . . . . . . . .4
Attaching the accessory holder . . . . . . .4
Setting the suction tube . . . . . . . . . . . . . .4
Filling the water filter container . . . . . .4-5
Switching on . . . . . . . . . . . . . . . . . . . . . .5
Working with the carpet turbo nozzle,
hard floor nozzle, crevice nozzle,
upholstery nozzle and furniture brush . . .6
Suction control . . . . . . . . . . . . . . . . . . . . .6
Wet vacuuming . . . . . . . . . . . . . . . . . . . .6
Taking a break . . . . . . . . . . . . . . . . . . . . .7
Storage of accessories . . . . . . . . . . . . . .7
Shutdown, transporting and storing . . . .7
Care / Maintenance
Cleaning the appliance and accessories 8
Changing the intermediate filter . . . . . . .8
Changing the HEPA combination filter . .8
Cleaning the suction manifold in the
water filter container . . . . . . . . . . . . . . . .9
Service
Warranty . . . . . . . . . . . . . . . . . . . . . . . . .9
Customer service . . . . . . . . . . . . . . . . . .9
Technical specifications . . . . . . . . . . . . .9
Circuit diagram . . . . . . . . . . . . . . . . . . . .9
Troubleshooting . . . . . . . . . . . . . . . . . . . .10
Assembly diagram . . . . . . . . . . . . . . . .11
USA: 1-800-537-4129
CAN: 1-800-465-4980
01-800-024-13-13
MEX:
Manual Part No. 5.960-032.0
Download from Www.Somanuals.com. All Manuals Search And Download.
K5500 Vacuum Manual7/24 7/29/02 11:33 AM Page 4
IMPORTANT SAFETY INSTRUCTIONS – Read First!
ASSEMBLY INSTRUCTIONS
14. Always turn off this appliance before
Safety Warnings
connecting or disconnecting motorized
When using an electrical appliance, basic
nozzle.
precautions should always be followed,
including the following:
15. Hold plug when rewinding onto cord
reel. Do not allow plug to whip when
rewinding.
READ ALL INSTRUCTIONS
BEFORE USING THIS APPLIANCE
16. This appliance is provided with double
insulation. Use only identical
replacement parts. See instructions for
Servicing of Double-Insulated
Appliances.
WARNING-To reduce the risk of fire,
electric shock, or injury:
1. Do not leave appliance when plugged
in. Unplug from outlet when not in use
and before servicing.
2. WARNING-To Reduce The Risk Of
Electric Shock. Do not use outdoors or
on wet surfaces."
1. Preparation
2. Attaching the accessory holder
• Connect the handle to the telescopic
suction tube.
• Connect the suction hose
17. Do not pick up anything that is burning
or smoking, such as cigarettes,
matches, or hot ashes.
• Connect the telescopic suction tube
and carpet turbo nozzle.
The accessory holder is for storing the
furniture brush and upholstery nozzle.
18. Do not use without all filters in place.
3. Do not allow to be used as a toy.
Close attention is necessary when
used by or near children.
SAVE THESE INSTRUCTIONS!
4. Use only as described in this manual.
Use only manufacturer's
OPERATING INSTRUCTIONS
SERVICING OF DOUBLE-
INSULATED APPLIANCES
In a double-insulated appliance, two
systems of insulation are provided
instead of grounding. No grounding
means is provided on a double-
insulated appliance, nor should a
means for grounding be added to the
appliance. Servicing a double-insulated
appliance requires extreme care and
knowledge of the system, and should
be done only by qualified service
personnel. Replacement parts for a
double-insulated appliance must be
identical to the parts they replace.
recommended attachments.
4
3
5. Do not use with damaged cord or
plug. If appliance is not working as it
should, has been dropped, damaged,
left outdoors, or dropped into water,
return it to a service center.
6. Do not pull or carry by cord, use cord
as a handle, close a door on cord, or
pull cord around sharp edges or
corners. Do not run appliance over
cord. Keep cord away from heated
surfaces.
7. Do not unplug by pulling on cord. To
unplug, grasp the plug, not the cord.
8. Do not handle plug or appliance with
wet hands.
9. Do not put any object into openings.
Do not use with any opening blocked;
keep free of dust, lint, hair, and
anything that may reduce air flow.
10. Keep hair, loose clothing, fingers, and
all parts of body away from openings
and moving parts.
click
1. Setting telescopic suction tube
2. Filling the water filter container
• Press the unlock button and pull out the
water filter container.
• Unlock the tube by moving the lock ring
and set the tube to the desired length by
drawing the inner pipe out or by sliding it
in further.
The appliance is delivered with the
intermediate filter and curved air guard
already assembled. When filling the container,
ensure that these components (see: Supplied
items) have been assembled correctly. They
may be the cause of poor suction
You can vacuum in a comfortable, upright
position by setting the telescopic suction
pipe to suit your height.
performance or premature failure of the
intermediate filter.
Customer Service
USA: 1-800-537-4129
11. Turn off all controls before unplugging.
12. Use extra care when cleaning on
stairs.
13. Do not use to pick up flammable or
combustible liquids, such as gasoline,
or use in areas where they may be
present.
CAN: 1-800-465-4980
01-800-024-13-13
MEX:
Download from Www.Somanuals.com. All Manuals Search And Download.
K5500 Vacuum Manual7/24 7/29/02 11:33 AM Page 6
OPERATING INSTRUCTIONS – continued
OPERATING INSTRUCTIONS – continued
4. Using the carpet turbo nozzle
• Remove the cover from the water filter
container and fill the water filter container
up to the MAX mark with tap water
(approximately 2 liters or 1/2 gallon).
• Add a capful of anti-foaming liquid
(Kärcher Foam Stop) to the water filter
container.
Slide the turbo control switch on the floor nozzle to a regulate the brushing action.
Full closed (+) increases brushing action for deep pile carpets and full open (-) for
5. Use and assembly of
the hard floor nozzle
The hard floor nozzle includes nylon and
The vacuum cleaner operates on the basis of swirling suction air into the water
filter. The vacuumed material and detergent residues from the floor covering are
being filtered in the water bath. Under certain circumstances this may result in the
formation of foam. To prevent this, add a capful of anti-foaming liquid to the water
filter bath. The anti-foaming liquid is environmentally friendly and completely
biodegradable. Slight foam formation during operation is normal and does not
impair function.
natural bristle brush inserts for cleaning
smooth hard surfaces. Use the nylon brush
set for ceramic tile or similar scratch
resistant surfaces. Use the soft natural
brushes for finished wood floors or other
scratch sensitive surfaces. To change the
5
6
brushes use a flat bladed screw driver or putty knife to gently pry open the plastic nozzle clips
to release the brush inserts. Then slide the replacement brushes into the white plastic holder
and snap holder back into place. Brushes must be replaced as a set for proper operation.
click
• Re-attach the cover. Push in the water
filter container all the way and pull up
until it “clicks” into position.
3. Switching on
• Unwind the power chord completely and
insert the plug into the power outlet.
6. Suction control (false-air slide) 7. Using the crevice nozzle
Crevice nozzle: For edges, crevices,
Due to the high constant suction capacity
of the appliance, the suction nozzles may
be too powerful for cleaning carpets,
upholstery, curtains, etc. In this case use
the false air slide to reduce the suction
capacity. After use, close again.
radiators, etc.
Upholstery nozzle: For cleaning upholstery
and curtains
Furniture brush: (can be rotated 360°)
For gentle cleaning of furniture, dusting
books, dashboards, etc.
If the water level in the container drops
below the “MIN” mark during operation,
Do not vacuum large quantities of powdered
please refill with water.
• To switch on, press the On/Off switch.
substances such as cocoa, flour, washing
powder, custard powder, etc.
8. Wet vacuuming
Use either the crevice nozzle, upholstery nozzle or the hard surface nozzle with the nylon
bristles for vacuuming wet surfaces (do not use the carpet turbo nozzle for wet surfaces).
• When the water filter container is empty, up to 2.5 liters or 1/2 gallon of liquid can be
vacuumed.
Damp dirt or small quantities of liquid up to approximately 0.5 liters or 2 cups can be
vacuumed at any time when the water filter container is full. Use the crevice nozzle or the
handle without attached accessory.
Download from Www.Somanuals.com. All Manuals Search And Download.
K5500 Vacuum Manual7/24 7/29/02 11:33 AM Page 8
OPERATING INSTRUCTIONS – continued
CARE AND MAINTENANCE
9. Storage of accessories
WARNING • Before any care and maintenance
• After use, attach upholstery nozzle and
furniture brush to the accessory holder.
• Store the crevice nozzle and the Kärcher
foam stop on the appliance.
work on the machine, unplug
the power cord.
1. Cleaning the appliance
and accessories
• If required, wipe down the exterior of
the appliance with a damp cloth. Do
not use any aggressive agents such as
scouring powder.
• The suction hose and handle can be
dismantled for cleaning.
• Check the accessories for blockages and,
if required, clean. Do NOT use water to
clean the floor nozzle.
Press in on the left and right hose release
clips at the same time to dismantle the
hose for cleaning.
11. Shut down for storage
10. Taking a break
• To switch off, press the On/Off button.
• To switch off, press the On/Off button.
• Pull the plug out of the power outlet.
2. Changing the intermediate filter
• If taking a break from work, attach the
floor nozzle to the appliance.
• Under normal conditions of use please
change the intermediate filter after at least
8 weeks or earlier if required (see page 2,
model 5500 overview item number 13).
• Press the cord rewind button. The power
cord is automatically wound up.
7
8
Note: After each use, the water filter
container, filter cover and baffle plate must
be cleaned and dried.
The intermediate filter must be disposed of in
the residual waste.
3. Changing the HEPA filter
The HEPA-Plus filter consists of the HEPA
filter and an exhaust air filter. To ensure
that the appliance cleans and functions
optimally, this filter should be changed
after 15 months. If damaged or very dirty,
change earlier.
IMPORTANT
• Do not wash the
HEPA-Plus filter!
• Take the water filter container out of the
appliance (see: Filling the water filter
container).
• Clean and dry the cover and water filter
container.
• If the appliance is used regularly, wash
the intermediate filter every 2 weeks under
running water.
• Remove the cover and air guard.
• Empty the water filter container via one
of the corners.
12. Transporting / Storing
• Transport the appliance by the
carrying handle.
• Remove the cover.
• Remove the HEPA-Plus filter.
CAUTION
• Insert a new HEPA-Plus filter, ensuring that
it “clicks” into position.
•
All parts of the water filter system,
especially the intermediate filter,
must be dried thoroughly before
being stored!
• To ventilate the water filter container while
the appliance is in storage, do not insert
container fully into the appliance.
• Attach the cover, ensuring that it “clicks”
into position.
Download from Www.Somanuals.com. All Manuals Search And Download.
K5500 Vacuum Manual7/24 7/29/02 11:33 AM Page 10
CARE AND MAINTENANCE – continued
TROUBLE SHOOTING
Often symptoms have causes which you can fix yourself with the aid of the following table. In
case of doubt, or if you encounter a symptom or cause not listed, please consult an authorized
Customer Service center.
Symptom
Cause
Solution
Machine does
not work.
Pull out power cord, check the
connection plug and power cord for
damage.
Current power supply has
been interrupted.
Suction
Air guard is missing or not
inserted correctly.
Insert air guard correctly (see model
overview page 1 & 2).
performance
decreases during
operation.
4. Cleaning the suction manifold
in the water filter container
Intermediate filter in
container cover wet.
Wash and dry intermediate filter
or insert a new filter
(see Care / Maintenance page 7 & 8).
•
Deposits in the suction manifold can be
removed by rinsing from above with a jet
of water.
Too little or too much water
in the water container.
Check MIN / MAX mark on the
container.
Intermediate filter
in container cover
is wet.
Excessive foam formation in Change water and add 1–2 capfuls of
SERVICE
the water filter container.
Kärcher foam stop. Wash and dry
intermediate filter or insert a new filter.
Warranty
Suction
performance
inadequate.
Customer Service
USA: 1-800-537-4129
Intermediate filter is missing
or not inserted correctly.
Check.
Please refer to the warranty card included
with the product. Should you have any
questions regarding the warranty please feel
free to call our customer service department.
HEPA-Plus filter is dirty.
Intermediate filter is dirty.
Accessory blocked.
Change HEPA-Plus filter
9
10
(see Care / Maintenance page 7 & 8).
CAN: 1-800-465-4980
Wash filter; if required, insert new filter
(see Care and Maintenance page 7 & 8).
01-800-024-13-13
MEX:
Remove blockage.
Deposits in suction manifold. Remove deposits (see Care and
Maintenance page 7 & 8).
Water container not
inserted correctly.
Check (see Operation page 3 & 4).
Technical Specifications
Circuit diagram
False air slide on
handle open.
Close false air slide.
Rated voltage
Rated frequency
Power P max
Power P nom
Vacuum
120 V
60 Hz
1400 W
1200 W
90.55 inches water lift
S1 Vacuum motor switch
C1 Interference suppressor
M1 Turbine
Excessive foam
formation in the
container.
No or inadequate Foam
Stop.
Change water and add 1 capful of
Foam Stop to the water filter container.
X1 Plug with cable rewinder
Air flow rate
116.54 cubic feet per minute
Repair work on this machine may only be carried out by an authorized Kärcher Service Center.
Capacity of water filter container 1/2 gallon
Sound level
69 dB( A)
Weight without accessories
Connection cable
Dimensions
Nominal width, accessory
HEPA - Plus filter
18 3/4 pounds
18 feet
19 x 12 x 24 inches
Ø 1.5 inches
H 12 class in compliance
with EN 1822
Customer Service
USA: 1-800-537-4129
WARNING!
To reduce the risk
of fire or electric
shock, do not remove this
cover, No user serviceable
parts inside. Repair should
be done by authorized
service personnel only.
CAN: 1-800-465-4980
We reserve the right to introduce technical
changes without prior notice.
01-800-024-13-13
MEX:
Download from Www.Somanuals.com. All Manuals Search And Download.
K5500 Vacuum Manual7/24 7/29/02 11:33 AM Page 12
D
A
C
C
B
11
D
B
A
Download from Www.Somanuals.com. All Manuals Search And Download.
|