.Unit components
Symbols on the machine
Please fold out illustration page at the front
1 Nozzle rest
High-pressure jets can be dan-
gerous if improperly used. The
jet must not be directed at per-
sons, animals, live electrical equipment or
at the appliance itself.
2 Handle
3 High-pressure outlet
4 Water connection
5 Manometer
The appliance is not suited for use
in the drinking water supply net-
work. It is necessary to install a
6 Oil level display
7 Oil reservoir
suitable system separator from Kaercher, if
the device is to be used in the drinking wa-
ter supply network.
8 Hood
9 Unit switch
10 Fastening screw for hood
11 Hose rest
Use of the cleaner
12 Handgun support
13 Nozzle
Use this unit exclusively for
14 Marking of the nozzle
15 Spray lance
– cleaning with high-pressure jet and deter-
gent (e.g. cleaning of machines, vehicles,
buildings, tools),
16 Pressure/flow control
17 Hand-held spray gun
18 Safety catch of hand-held spray gun
19 Lever of hand-held spray gun
20 High-pressure hose
21 Push-handle
– cleaning with high-pressure jet without de-
tergent (e.g. cleaning facades, terraces,
gardening equipment).
For stubborn dirt we recommend the dirt
blaster as an optional accessory (for HD ...
Plus included in the delivery).
22 Cable holder
23 Detergent metering valve
24 Detergent suction hose with filter and
screw cap
25 Bottle holder for detergent
3
Download from Www.Somanuals.com. All Manuals Search And Download.
English
Safety features
Preparing the unit for use
Overflow valve with pressure
switch
On reducing the flow rate with the pressure
and flow control, the relief valve opens and
part of the water runs back to the suction side
of the pump.
Unpack the unit
– When unpacking the unit, check the con-
tents of the packaging. If there has been
any damage in transit inform the dealer.
– Do not dispose of the packaging with the
household rubbish, hand it in at the appro-
priate collection point for recycling.
If the lever of the hand-held spray gun is re-
leased, the pressure switch switches the
pump off. If the lever is retracted, the pressure
switch switches the pump on again.
Check the oil level
Read the oil level displayed while unit is at
a standstill. The oil level must be above the
two indicators.
Safety valve
The safety valve opens when the admissible
operating excess pressure is exceeded; the
water flows back to the pump suction side.
Activate the oil reservoir vent
Unscrew the fastening screw of the hood
and remove the hood.
Overflow valve, pressure switch and safety
valve are present in the factory and are
sealed.
Cut off the tip on the cover to the oil reservoir.
Fasten the unit cover.
Adjustments are made only by Customer
Service.
Mount the accessories
Mount nozzle on the spray lance (see
markings on the top of the setting ring).
Protection of the
environment, disposal
Fit the spray lance to the hand-held spray
gun with pressure and flow control.
Screw on high-pressure hose to the high-
pressure outlet.
The packaging material can be re-
cycled. Please do not place the pak-
kaging into the ordinary refuse for
disposal, but arrange for the proper
recycling.
Switching on the unit
Electrical connection
Old appliances contain valuable ma-
terials that can be recycled. Please
arrange for the proper recycling of
old appliances. Batteries, oil, and si-
milar substances must not enter the
environment. Please dispose of your
old appliances using appropriate col-
lection systems.
Caution!
The appliance may only be connected
to alternating current. The voltage must corre-
spond with the type plate on the appliance.
Caution!
Use if required an extension cable with
sufficient cable cross-section (refer technical
details)and always fully unroll the cable from
the cable drum.
4
Download from Www.Somanuals.com. All Manuals Search And Download.
English
Unsuitable extension cables can be hazard-
ous. Only use extension cables outdoors
which have been approved for this purpose
and labelled with a sufficient cable cross sec-
tion:
Suctioning water from an open container
Screw on the suction hose (order no.
4.440-270) on the water connection.
Attach the filter (order no. 4.730-012) at the
suction hose.
For connected loads see model rating plate/
Technical Specifications.
Vent the unit before using.
To evacuate air from the unit, unscrew the
nozzle and leave the unit running until wa-
ter exits with no air bubbles. If necessary
allow unit to continue running for 10 sec-
onds and then switch off. Repeat this pro-
cedure several times.
Caution!
It is essential that the unit is connected
to the power supply by means of a plug. An in-
separable connection to the power supply is
prohibited. The plug is used to disconnect
from the mains.
Switch off the unit and screw the nozzle
back on.
Check the power cord with mains plug for
damage before every use. If the power cord is
damaged, please arrange immediately for the
exchange by an authorized customer service
or a skilled electrician.
Operating the unit
The appliance may only be connected to an
electrical supply which has been installed in
accordance with IEC 60364.
The minimum fuse rating required at the sock-
et outlet is (see technical specifications).
The plug and coupling of the extension cable
used must be watertight.
Danger!
!
Observe the relative safety regulations
when using the unit at filling stations or other
high-risk areas.
Caution!
Only clean engines in places which
have appropriate oil separators (protection of
the environment).
Water connection/Suction feed
operation
Caution!
The jet must not be directed at other
persons or directed by the user at him/herself to
clean clothing or footwear.
Connection to water main
Caution!
Pay attention to the regulations of the
water supply company; according to DIN
1988, the unit may not be connected direct to
the public drinking water supply. A short-term
connection via a non-return valve
(Order no. 6.412-578) is allowed.
Only wash animals with the low-pressure fan jet
(see "Selecting the type of spray").
Operating with high pressure
The unit is equipped with a pressure switch.
The motor only starts up when the lever is re-
tracted.
For connected loads see Technical Specifica-
tions.
Set the unit switch to "I".
Connect a supply hose (not supplied) to the
water outlet on the unit and to the water in-
let (e.g. water tap).
Unlock the hand-held spray gun and retract
the lever of the gun.
Adjust operating pressure and flow rate
(+/–) by rotating the pressure/flow control
(infinitely variable).
Open water inlet.
5
Download from Www.Somanuals.com. All Manuals Search And Download.
English
Set the detergent dosage
valve to the desired detergent
and the desired concentration.
Selecting the type of spray
The handgun must be closed.
Rotate the housing of the nozzle until the
desired symbol corresponds with the
marking:
Recommended cleaning
High-pressure pencil jet
for particularly stubborn accu-
mulation of grime.
methods
Spray detergent with low pressure jet spar-
ingly over the dry surface to be cleaned and
let it take effect but not dry out.
Low-pressure fan jet
for operating with detergent or
cleaning with negligible pressu-
re.
Spray off (rinse off) the loosened dirt using
the high-pressure spray.
After use immerse filter in clean water.
Turn metering valve to maximum cleaning
agent concentration setting. Start unit and
rinse through for one minute.
High-pressure fan jet
for dirt accumulation over a lar-
ge surface.
Interrupting the operation
Release lever of the handgun, the unit
switches off. Retract lever again and the
unit switches on again.
Operating with detergent
Caution!
Unsuitable detergents can harm the
cleaner and the object which is to be cleaned.
Use only detergents which are released by
Kärcher. Proportions of detergent to be used
and accompanying instructions should be not-
ed carefully. Use detergents sparingly out of
consideration for the environment.
Switching the unit off
Set unit switch to "0" and pull out power plug.
Close water inlet.
Retract lever until the unit is without pres-
sure.
Actuate the handgun's safety catch to se-
cure the handgun lever from accidentally
being triggered.
Kärcher cleaning agents guarantee trouble-
free operation. Please seek advice or ask for
our catalogue of information sheets on clean-
ing agents.
Transporting the cleaner
Put the detergent bottle into the bottle hold-
er at the appliance or place detergent can
next to the appliance. Two different deter-
gents can be placed in the appliance at the
same time.
To transport the appliance over long dis-
tances use the push handle to pull the ap-
pliance.
When carrying the appliance always use
the handle, not the push handle.
Pull out the cleaning agent suction hose
and immerse the filter in the cleaning agent
canister.
Prior to a transport in the horizontal position
remove the detergent bottles from the bottle
holder and close them.
Screw on the screw cap on the bottle or can.
Set nozzle to
.
6
Download from Www.Somanuals.com. All Manuals Search And Download.
English
Storing the cleaner
Place the handgun in the support.
Before each use
Check connecting cable for damage (risk of
getting an electric shock), have a damaged
connecting cable replaced without delay by
authorised Customer Service personnel or
an electrician.
Reel in the high-pressure hose and hang it
over the hose rest.
or
Wind the high-pressure hose on to the
hose reel. Push in the crank handle to lock
the hose drum.
Check high-pressure hose for damage
(danger of explosion), replace a damaged
high-pressure hose without delay.
Wind the connection cable around the ca-
ble holder.
Check unit (pump) for any leaks.
Three drops per minute are allowable and
can appear on the underside of the unit.
Seek the help of Customer Service if leaks
are more serious.
Fix the plug using the installed clip.
Frost protection
Caution!
Frost will destroy a unit that is not com-
pletely empty of water! Store the unit where it
will be free of frost.
Every week
Check oil level in oil reservoir: if the oil is
milky (water in oil), seek the help of Cus-
tomer Service immediately.
If storage away from frost is not possible:
Drain off the water and rinse the unit
through with anti-freeze.
Clean the strainer in the water connection.
Clean the filter at the suction hose for de-
tergent.
Leave the unit to dry for max. 1 minute.
Use the standard glycol-based anti-freezes
for cars.
Annually or after 500 operating
hours
Follow the handling instructions of the anti-
freeze manufacturer.
Change the oil
– For oil quantity and type see Technical
Specifications.
Care and maintenance
– Undo the fastening screw, remove the
hood, remove the oil tank cover, tilt unit.
Danger!
!
Before any care and maintenance work
– Drain oil into a suitable container.
on the unit draw out the mains plug.
– Fill slowly with fresh oil; air bubbles have
to escape.
Caution!
When changing the oil, dispose of any
waste oil only at authorised collection points.
– Attach the oil tank cover.
Safety inspection/Maintenance
contract
Troubleshooting
You can arrange with your dealer to have a reg-
ular safety inspection carried out or to have a
maintenance contract. Please seek advice.
Danger!
!
Before any repair work is undertaken,
switch the unit off and pull out the power plug.
Have electrical components checked and re-
paired only by authorised Customer Service
personnel.
For faults which are not identified in this chap-
7
Download from Www.Somanuals.com. All Manuals Search And Download.
English
ter, or when in doubt or when expressly in-
structed to do so, consult authorised
Customer Service personnel.
Check detergent suction hose with filter for
leaks or obstructions and clean it if neces-
sary.
Open detergent metering valve or check it
for leaks/remove obstruction.
Unit does not work
Check connecting cable for damage.
Seek the help of Customer Service if nec-
essary.
Check the mains voltage.
Consult Customer Service if there is an
electrical fault.
Spare parts
Unit does not come up to pres-
sure
You will find a list of spare parts at the end of
these operating instructions.
Set nozzle to "high pressure".
Clean/replace nozzle.
Evacuate air from the cleaner (see Switch-
ing on the unit).
Warranty
Clean the strainer in the water connection.
The warranty terms issued by our authorised
marketing company are valid in every country.
We remedy any fault in the unit free of charge
within the warranty period providing the cause
of the fault proves to be a material or manu-
facturing error.
Check water inlet volume (see Technical
Specifications).
Check all supply lines to the pump for leaks
or obstructions.
Seek the help of Customer Service if nec-
The warranty only becomes operative when
your dealer has completed the reply card ac-
companying the sale of the unit, has stamped
and signed it and you have then sent the reply
card to the marketing company in your coun-
try.
essary.
Pump is leaky
Three drops per minute are allowable and
can appear on the underside of the unit.
Seek the help of Customer Service if leaks
are more serious.
Should you wish to call upon the guarantee,
please apply to your dealer or nearest author-
ised Customer Service centre taking along
also the accessories and bill of sale.
Pump makes a knocking noise
Check all supply lines as well as the deter-
gent system for leaks.
Close the cleaning agent metering valve
when running the unit without cleaning
agent.
Evacuate air from the cleaner (see Switch-
ing on the unit).
Seek the help of Customer Service if nec-
essary.
Detergent is not being drawn in
Set nozzle to "Chem".
8
Download from Www.Somanuals.com. All Manuals Search And Download.
English
EU Declaration of Conformity
We hereby declare that the equipment
described below conforms to the relevant
fundamental safety and health
S. Reiser
H. Jenner
requirements of the appropriate EU
Directives, both in its basic design and
construction as well as in the version
marketed by us.
This declaration will cease to be valid if any
modifications are made to the machine
without our express approval.
Alfred Kärcher GmbH & Co. KG
Cleaning Systems
D-71349 Winnenden
Alfred Kärcher Kommanditgesellschaft.
Sitz Winnenden;
Registergericht: Waiblingen, HRA 169.
Persönlich haftende Gesellschafterin:
Kärcher Reinigungstechnik GmbH; Sitz
Winnenden,
Product: High-pressure cleaner
Type:
1.524-xxx
Relevant EU Directives:
2404 Registergericht Waiblingen, HRB
Geschäftsführer: Dr. Bernhard Graf,
Hartmut Jenner, Georg Metz
EU Machinery Directive (98/37/CE)
EU Low-Voltage Equipment Directive
(73/23/EEC) amended by 93/68/EEC
EU Directive on Electromagnetic
Compatibility (89/336/EEC) as amended
by 91/263/EEC, 92/31/EEC, 93/68/EEC,
EU Directive on Noise Emissions (2000/
14/EU)
Internal measures are taken to ensure that
the series units always meet the
requirements of the current EC Directives
and the standards used.
The persons signing the above declaration
act on behalf of and with the authorisation
of the management.
Harmonised standards applied:
DIN EN 60 335 - 1
DIN EN 60 335 - 2 - 79
DIN EN 55 014 - 1 : 2000 + A1 : 2001 +
A2 : 2002
DIN EN 55 014 - 2 : 1997 + A1 : 2001
DIN EN 61 000 - 3 - 2 : 2000
DIN EN 61 000 - 3 - 3 : 1995 + A1 : 2001
(HD 7/18-4)
DIN EN 61 000 - 3 - 11 : 2001 (HD 6/16-4)
National standards applied: –
Conformity evaluation procedure applied:
Appendix V
Measured sound power level:
HD 6/13-4: 83 dB (A)
HD 7/10-4: 83 dB (A)
Guaranteed sound power level:
HD 6/13-4: 84 dB (A)
HD 7/10-4: 84 dB (A)
9
Download from Www.Somanuals.com. All Manuals Search And Download.
English
Technical Specifications
HD 6/13-4 M
1.524-103
HD 7/10-4 M
1.524-111
Mains connection
GB
GB
Voltage
Type of current
Rotation speed
Connected load
Supply fuse (delayed-action, char. C)
Extension cable 30 m
Water connection
V
240
1~50
1400
3,0
13
2,5
Hz
1/min
kW
A
2
mm
Supply temperature max.
Supply volume min.
°C
l/h (l/min)
m
Zoll
m
MPa
60
600 (10)
700 (11,7)
Supply hose – minimum length
Supply hose – minimum diameter
Suction height from an open container 20 °C
Supply pressure max.
Performance data
7,5
1
0,5
1
Operating pressure
Max. operating overpressure (safety valve)
Flow rate
MPa
MPa
3 – 13
16
250 – 600
(4,2 – 10)
3 – 10
13
300 – 700
(5 – 11,7)
l/h (l/min)
Detergent intake
l/h
0 – 40
(0 – 0,7)
30
(l/min)
Recoil force of the handgun
Sound emission
N
Sound pressure level (EN 60704-1)
Garanted sound pressure level (2000/14/EC) dB (A)
dB (A)
69
84
Vibrations of unit / total of vibration (ISO 5349)
2
Handheld gun
Spray lance
m/s
m/s
2,0
1,9
2
Dimensions
Length
Width (MX)
mm
mm
mm
kg
554
509
1000
43
Height
Weight without accessories
Oil quantity, pump
Oil type, pump
l
0,5
SAE 0W40
10