Johnson Controls Air Conditioner TCGF24 User Manual

TABULAR DATA SHEET  
Outdoor Split System Air Conditioner 2 Thru 5 Tons  
MODELS: TCGF24* THRU 60  
14.5 SEER – R-410A, 1 PHASE  
Physical and Electrical Data  
MODEL  
TCGF24S41S1 TCGF30S41S1 TCGF36S41S1 TCGF42S41S1 TCGF48S41S1 TCGF60S41S1  
Unit Supply Voltage  
208-230V, 1φ, 60Hz  
Normal Voltage Range 1  
Minimum Circuit Ampacity  
187 to 252  
16.8  
25  
18.4  
30  
19.1  
30  
23.9  
40  
27.9  
45  
35.9  
60  
Max. Overcurrent Device Amps 2  
Min. Overcurrent Device Amps 3  
Compressor Type  
20  
Scroll  
12.8  
58  
20  
Scroll  
14.1  
73  
20  
Scroll  
14.1  
77  
25  
Scroll  
17.9  
112  
No  
30  
Scroll  
21.1  
115  
No  
40  
Scroll  
27.5  
135  
No  
Rated Load  
Compressor  
Amps  
Locked Rotor  
Crankcase Heater  
No  
No  
No  
Fan Motor Amps Rated Load  
Fan Diameter Inches  
Rated HP  
.8  
.8  
1.5  
1.5  
1.5  
1.5  
22  
22  
22  
24  
24  
24  
1/8  
1/8  
1/4  
1/4  
1/4  
1/4  
Fan Motor  
Nominal RPM  
Nominal CFM  
Face Area Sq. Ft.  
Rows Deep  
1075  
2750  
13.1  
1
1075  
2800  
17.4  
1
850  
3200  
17.4  
1
850  
3600  
20.0  
1
850  
3600  
21.4  
1
850  
3700  
24.0  
1
Coil  
Fin / Inches  
23  
23  
23  
23  
23  
23  
Liquid Line Set OD (Field Installed)  
Vapor Line Set OD (Field Installed)  
Unit Charge (Lbs. - Oz.) 4  
Charge Per Foot, Oz.  
Operating Weight Lbs.  
3/8  
3/8  
3/8  
3/8  
3/8  
3/8  
3/4  
3/4  
3/4  
7/8  
7/8  
1 1/8  
5 - 9  
0.75  
199  
3 - 2  
0.62  
128  
3 - 7  
0.62  
130  
3 - 10  
0.62  
145  
4 - 4  
0.67  
172  
4 - 9  
0.67  
180  
1. Rated in accordance with ARI Standard 110, utilization range “A”.  
2. Dual element fuses or HACR circuit breaker. Maximum allowable overcurrent protection.  
3. Dual element fuses or HACR circuit breaker. Minimum recommended overcurrent protection.  
4. The Unit Charge is correct for the outdoor unit, matched indoor coil and 15 feet of refrigerant tubing. For tubing lengths other than  
15 feet, add or subtract the amount of refrigerant, using the difference in length multiplied by the per foot value.  
All dimensions are in inches. They are subject to change  
without notice. Certified dimensions will be provided upon  
request.  
C
Dimensions  
(Inches)  
Refrigerant Connection  
Service Valve Size  
Unit  
Model  
A1  
28  
36  
36  
34  
36  
40  
B
C
Liquid  
Vapor  
24  
30  
36  
42  
48  
60  
29  
29  
29  
29  
3/4”  
A
29  
29  
3/8”  
33.6  
33.6  
33.6  
33.6  
33.6  
33.6  
7/8”  
7/8”2  
1. Including Fan Guard.  
2. Adapter fitting required for 1-1/8” line set.  
B
Johnson Controls Unitary Products  
362564-UTD-B-0708  
Download from Www.Somanuals.com. All Manuals Search And Download.  
362564-UTD-B-0708  
R-410A SYSTEM CHARGING PROCEDURE  
Additional R-410A Charge / Orifice Size for Various Matched Systems (Continued)  
Outdoor Unit  
TCGF24S41S1 TCGF30S41S1  
TCGF36S41S1 TCGF42S41S1  
TCGF48S41S1  
1TVM905  
4 - 9  
TCGF60S41S1  
1TVM906  
5 - 9  
Required Orifice or TXV 1  
Factory Charge, lbs-oz  
1TVM902  
3 - 2  
1TVM903  
3 - 7  
1TVM903  
3 - 10  
1TVM903  
4 - 4  
Indoor Coil2,3,4  
AHP42C3X  
Additional Charge, Oz  
0
0
1
1
1
0
AHP/SHP60D3X  
AV24B3X  
3
AV36C3X  
25  
19  
15  
9
AV/SV48D3X  
AV/SV60D3X  
See Cautionbelow  
See Cautionbelow  
See Cautionbelow  
See Cautionbelow  
See Cautionbelow  
See Cautionbelow  
See Cautionbelow  
See Cautionbelow  
See Cautionbelow  
0
F4FP024  
F4FP030  
F4FP036  
F4FP040  
F4FP042  
F4FP045  
F5FP048  
F5FP060  
F4FV060  
3
0
8
5
12  
8
8
0
9
2
20  
20  
9
10  
10  
10  
11  
11  
1
FOOTNOTES:  
1. Systems matched with furnace or air handlers not equipped with blower-off delays may require blower Time Delay Kit 2FD06700224.  
2. PC coils cannot be used in downflow or horizontal applications. FC coils cannot be used in horizontal applications.  
3. A TXV kit must be used with these coils to obtain system performance. Note: If a TXV is factory installed on the coil, it must be replaced  
with the listed TXV  
4. Refer to Technical Guide for actual system performance and matches.  
PROCEDURES:  
1. Unit factory charge listed on the unit nameplate includes refrigerant for the condenser, the smallest evaporator and 15 feet of inter-  
connecting line tubing.  
2. Verify the TXV or orifice and additional charge required for specific evaporator coil in the system using the above table.  
3. Add additional charge for the amount of interconnecting line tubing greater than 15 feet at the rate specified in Physical and Electri-  
cal Data Table.  
4. For TXV match charge weight needs to be weighed in for specififc coil match and lineset length.  
5. Permanently mark the unit nameplate with the total system charge. Total System Charge = Base Charge (as shipped) + adder for  
evaporator + adder for line set.  
If the F*FP Air Handler used has a with a factory installed R-22 TXV it MUST BE CHANGED OUT to a R-410A TXV or a orifice for proper operation.  
If the TXV is not changed out system damage will occur.  
Johnson Controls Unitary Products  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
NOTES  
Subject to change without notice. Printed in U.S.A.  
Copyright © 2008 by Johnson Controls, Inc. All rights reserved.  
362564-UTD-B-0708  
Supersedes: 362564-UTD-A-0608  
*362564*  
Johnson Controls Unitary Products  
5005 York Drive  
Norman, OK 73069  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Indesit Washer WIE 107 User Manual
Insignia CRT Television NS 32DD200NA14 User Manual
JVC VCR HR 272EU User Manual
Kawasaki Battery Charger 840638 User Manual
Kelvinator Freezer KCS130G W User Manual
Kenmore Laptop T210 User Manual
Kenwood Car Speaker KFC 1013C User Manual
Kenwood Stereo Receiver KRC 279RA User Manual
Keys Fitness Fitness Equipment STDFR B User Manual
KitchenAid Dishwasher 9743822 User Manual