TABULAR DATA SHEET
Outdoor Split System Air Conditioner 2 Thru 5 Tons
MODELS: TCGF24* THRU 60
14.5 SEER – R-410A, 1 PHASE
Physical and Electrical Data
MODEL
TCGF24S41S1 TCGF30S41S1 TCGF36S41S1 TCGF42S41S1 TCGF48S41S1 TCGF60S41S1
Unit Supply Voltage
208-230V, 1φ, 60Hz
Normal Voltage Range 1
Minimum Circuit Ampacity
187 to 252
16.8
25
18.4
30
19.1
30
23.9
40
27.9
45
35.9
60
Max. Overcurrent Device Amps 2
Min. Overcurrent Device Amps 3
Compressor Type
20
Scroll
12.8
58
20
Scroll
14.1
73
20
Scroll
14.1
77
25
Scroll
17.9
112
No
30
Scroll
21.1
115
No
40
Scroll
27.5
135
No
Rated Load
Compressor
Amps
Locked Rotor
Crankcase Heater
No
No
No
Fan Motor Amps Rated Load
Fan Diameter Inches
Rated HP
.8
.8
1.5
1.5
1.5
1.5
22
22
22
24
24
24
1/8
1/8
1/4
1/4
1/4
1/4
Fan Motor
Nominal RPM
Nominal CFM
Face Area Sq. Ft.
Rows Deep
1075
2750
13.1
1
1075
2800
17.4
1
850
3200
17.4
1
850
3600
20.0
1
850
3600
21.4
1
850
3700
24.0
1
Coil
Fin / Inches
23
23
23
23
23
23
Liquid Line Set OD (Field Installed)
Vapor Line Set OD (Field Installed)
Unit Charge (Lbs. - Oz.) 4
Charge Per Foot, Oz.
Operating Weight Lbs.
3/8
3/8
3/8
3/8
3/8
3/8
3/4
3/4
3/4
7/8
7/8
1 1/8
5 - 9
0.75
199
3 - 2
0.62
128
3 - 7
0.62
130
3 - 10
0.62
145
4 - 4
0.67
172
4 - 9
0.67
180
1. Rated in accordance with ARI Standard 110, utilization range “A”.
2. Dual element fuses or HACR circuit breaker. Maximum allowable overcurrent protection.
3. Dual element fuses or HACR circuit breaker. Minimum recommended overcurrent protection.
4. The Unit Charge is correct for the outdoor unit, matched indoor coil and 15 feet of refrigerant tubing. For tubing lengths other than
15 feet, add or subtract the amount of refrigerant, using the difference in length multiplied by the per foot value.
All dimensions are in inches. They are subject to change
without notice. Certified dimensions will be provided upon
request.
C
Dimensions
(Inches)
Refrigerant Connection
Service Valve Size
Unit
Model
A1
28
36
36
34
36
40
B
C
Liquid
Vapor
24
30
36
42
48
60
29
29
29
29
3/4”
A
29
29
3/8”
33.6
33.6
33.6
33.6
33.6
33.6
7/8”
7/8”2
1. Including Fan Guard.
2. Adapter fitting required for 1-1/8” line set.
B
Johnson Controls Unitary Products
362564-UTD-B-0708
Download from Www.Somanuals.com. All Manuals Search And Download.
362564-UTD-B-0708
R-410A SYSTEM CHARGING PROCEDURE
Additional R-410A Charge / Orifice Size for Various Matched Systems (Continued)
Outdoor Unit
TCGF24S41S1 TCGF30S41S1
TCGF36S41S1 TCGF42S41S1
TCGF48S41S1
1TVM905
4 - 9
TCGF60S41S1
1TVM906
5 - 9
Required Orifice or TXV 1
Factory Charge, lbs-oz
1TVM902
3 - 2
1TVM903
3 - 7
1TVM903
3 - 10
1TVM903
4 - 4
Indoor Coil2,3,4
AHP42C3X
Additional Charge, Oz
–
–
–
–
–
–
–
–
–
–
0
0
–
–
1
–
–
1
1
–
–
–
–
–
–
0
–
AHP/SHP60D3X
AV24B3X
3
–
–
AV36C3X
25
–
19
–
15
9
AV/SV48D3X
AV/SV60D3X
–
–
–
See Cautionbelow
See Cautionbelow
See Cautionbelow
See Cautionbelow
See Cautionbelow
See Cautionbelow
See Cautionbelow
See Cautionbelow
See Cautionbelow
0
–
–
F4FP024
F4FP030
F4FP036
F4FP040
F4FP042
F4FP045
F5FP048
F5FP060
F4FV060
3
–
–
–
–
–
–
–
0
8
–
5
–
–
–
–
–
–
–
–
–
–
–
–
12
–
8
–
–
8
0
–
–
9
2
–
–
20
20
9
10
10
10
11
11
1
–
–
FOOTNOTES:
1. Systems matched with furnace or air handlers not equipped with blower-off delays may require blower Time Delay Kit 2FD06700224.
2. PC coils cannot be used in downflow or horizontal applications. FC coils cannot be used in horizontal applications.
3. A TXV kit must be used with these coils to obtain system performance. Note: If a TXV is factory installed on the coil, it must be replaced
with the listed TXV
4. Refer to Technical Guide for actual system performance and matches.
PROCEDURES:
1. Unit factory charge listed on the unit nameplate includes refrigerant for the condenser, the smallest evaporator and 15 feet of inter-
connecting line tubing.
2. Verify the TXV or orifice and additional charge required for specific evaporator coil in the system using the above table.
3. Add additional charge for the amount of interconnecting line tubing greater than 15 feet at the rate specified in Physical and Electri-
cal Data Table.
4. For TXV match charge weight needs to be weighed in for specififc coil match and lineset length.
5. Permanently mark the unit nameplate with the total system charge. Total System Charge = Base Charge (as shipped) + adder for
evaporator + adder for line set.
If the F*FP Air Handler used has a with a factory installed R-22 TXV it MUST BE CHANGED OUT to a R-410A TXV or a orifice for proper operation.
If the TXV is not changed out system damage will occur.
Johnson Controls Unitary Products
3
Download from Www.Somanuals.com. All Manuals Search And Download.
NOTES
Subject to change without notice. Printed in U.S.A.
Copyright © 2008 by Johnson Controls, Inc. All rights reserved.
362564-UTD-B-0708
Supersedes: 362564-UTD-A-0608
*362564*
Johnson Controls Unitary Products
5005 York Drive
Norman, OK 73069
Download from Www.Somanuals.com. All Manuals Search And Download.
|