JLBIHD105
built-in cooker hood
Instruction manual
Download from Www.Somanuals.com. All Manuals Search And Download.
Contents
For the User
For the Installer
Important Safety Information
Description of the Appliance
2
4
Electrical Connections
Electrical Requirements
Electrical Connection
9
9
9
Using the cooker hood
Cooker Hood Controls
To Operate
Recirculation
Extraction
10
10
10
10
10
Installing the Cooker Hood
Installation Requirements
Unpacking
Fitting theWall Brackets
Fitting the Canopy Hood
Extraction
5
5
5
6
6
7
7
8
Maintenance and Cleaning
External Cleaning
Grease Filters
Charcoal Filters
To Remove/Replace Charcoal Filter
Changing the Light Bulb
11
11
11
12
12
12
Recirculation
Fitting the Chimney Stack
Something NotWorking
Repairs and After Sales Service
Spare Parts
13
13
14
Guide to use the Instruction Manual
The following symbols will be found in the text to guide
you through the instruction book
Safety instructions
Step by step instructions
Environmental Information
This appliance complies with the fol-
lowings E.E.C. Directives:
- 89/336 (Electromagnetic Compat-
ibility Directive)
- 73/23 (LowVoltage Directive)
- 93/68 (General Directives)
and subsequent modifications
3
Download from Www.Somanuals.com. All Manuals Search And Download.
Description of the Appliance
132
100
300
150
4
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation
Please ensure that when the appliance is installed
it is easily accessible to an engineer in the event
of a breakdown.
All installations must comply with the local
authorities requirements for the discharge of
exhaust air.
Incorrect installation may affect the safety of
this cooker hood.
Installation Requirements
Before installation check the wall to which
the cooker hood is to be fitted for electric
cables, water pipes or gas.
This cooker hood is designed to be fixed to any vertical
surface over a cooking area,and can be used in the extrac-
tion (ducted to the outside) or recirculation mode.
The installation work must be undertaken by a qualified
and competent person.
The manufacturer disclaims any responsibility for dam-
age due to incorrect installation of the cooker hood or
if the hood is not installed in compliance with relevant
regulations controlling this type of installation.
15
Unpacking
Before unpacking the cooker hood position the carton
with the arrows pointing upwards as illustrated on the
carton.
14.1
The cooker hood is made up of the following compo-
nents:
7.2.1
14
10
Ref Qty Product Components
1
1
Canopy complete with: Controls, Light-
ing, Fan Assembly, Grease Filter, Charcoal
Filter.
9
2
1
1
1
1
1
1
1
1
2
1
Telescopic Chimney comprising:
Upper Chimney Stack
Lower Chimney Stack
Right-Hand Recirculation grille
Left-Hand Recirculation grille
ø150-120 Ducting Spigot
ø120-125 Ducting flange
Ducting Extension Pipe
Recirculation Outlet Extentions
Recirculation Outlet Adapter
2.1
2.2
8a
8b
9
10
14
14.1
15
2.1
12c
8a
2
8b
2.2
Ref Qty Installation Components
7.2.1
12c
2
6
Upper chimney wall fixing brackets
Chimney fixing screws
Ref Qty Documentation
Instruction booklet
1
1
5
Download from Www.Somanuals.com. All Manuals Search And Download.
Installing the Cooker Hood
Fitting theWall Brackets
•
Draw a vertical line on the supporting wall up to the
ceiling, or as high as practical, at the centre of the area
in which the hood will be installed.
•
•
Draw a horizontal line at 650 mm above the hob.
Place bracket item 7.2.1 on the wall as shown about 1-2
mm from the ceiling or upper limit aligning the centre
(notch) with the vertical reference line.
7.2.1
•
•
Mark the wall at the centres of the holes in the brack-
et.
Place bracket item 7.2.1 on the wall as shown at X mm
below the first bracket (X = height of the upper chim-
ney section supplied), aligning the centre (notch) with the
vertical line.
116 116
•
•
Mark the wall at the centres of the holes in the brack-
et.
Draw a horizontal line through the vertical at 340 mm
above the hob and mark two hole centres at 116 mm
either side of the vetical line.
•
•
•
•
Drill ø 8 mm holes at all the centre points marked.
Insert the wall plugs (not supplied) in the holes.
Fix the brackets using the screws (not supplied).
Insert two screws into the two holes 116 mm either side
of the vertical line and tighten leaving a space between
the underside of the screwhead and the wall of 5-6mm.
Note: If the hood is to be installed onto a hollow
construction or plaster or partition board wall
then special fixing screws will be required (not
supplied).
Vr
Fitting the Canopy Hood
•
Before starting to fix the hood body, tighten the two
screws item Vr located on the top of the hood body.
Hook the hood body onto the two screws item 12a.
Fully tighten the screws item 12a.
•
•
•
Using a screw driver and spirit level, adjust the screws
item Vr until the hood body is level.
12a
6
Download from Www.Somanuals.com. All Manuals Search And Download.
Extraction (Ducted)
The cooker hood is more effective when installed in the
extraction mode (ducted to the outside).
Venting kits may be purchased through your retailer or
DIY store, and must be evacuated through an outside
vent of ø125 (5ins) or ø150mm (6ins).
The ducting used must be manufactured from fire
retardent material conforming to the relevant British
Standard or DIN 4102-B1.
When the cooker hood is ducted to the outside
the charcoal filter must be removed.
Fitting the Ducting
Fit the ø150mm (6ins) ducting to the spigot on top of
the hood body as illustrated.
When using ø125mm (5ins) ducting fit item 9 and 10
on to the spigot on the top of the hood body as illus-
trated.
•
•
ø 125
ø 150
•
•
For the best performance use the shortest possible run
of ducting and we recommend the use of rigid pipe in
preference to flexible hose as this will improve the flow
of air while reducing turbulence, which causes noise and
a loss of performance.
If the room where the cooker hood is to be used contains
a fuel burning appliance such as a central heating boiler,
then its flue must be be of the room sealed or balanced
flue type.
10
9
•
•
If other types of flue or appliances are fitted ensure that
there is an adequate supply of air to the room.
The cooker ducting when fitted in the extraction mode
must never be connected to central heating flues, radiators
or water heaters.
Recirculation Mode
The cooker hood is supplied specified for use in the recircula-
tion mode, with the charcoal filter fitted.
15
14.1
In the recirculation mode contaminated air is passed through
the charcoal filter to be purified and recirculated into the kitch-
en through the grille outlets on either side of the chimney.
8b
8a
•
•
•
•
•
•
Assemble the two halves of the ducting extension pipe
item 14.
Push-fit the extension pipe on to the ducting spigot on
top of the canopy.
Push-fit the recirculation adapter item 15 on to extension
pipe item 14.
Insert the recirculation outlet extensions item 14.4 into
the recirculation adapter item 15.
14
The recircualtion grilles item 8a and 8b must be fitted
after the lower chimney item 2.2 has been fitted.
Ensure the activated charcoal filter has been fitted.
7
Download from Www.Somanuals.com. All Manuals Search And Download.
Fitting the Upper Chimney
Expand the sides of the upper chimney stack item 2.1 and
place the chimney over the two brackets 7.2.1 ensuring
they are well seated.
Secure the chimney stack to the brackets 7.2.1 using
the four self tapping screws item 12c (2.9 x 9.5mm)
supplied.
•
•
7.2.1
12c
2.1
2
Fitting the Lower Chimney
8b
2.2
8a
•
Expand the of the lower chimney stack item 2.2 and place
the chimney over the upper chimney stack item 2.1 and
the canopy.
•
•
Secure the chimney stack to the canopy using the two
screws item 12c (2.9 x 9.5mm) supplied..
After the chimney has been secured into position, insert
the two plastic recirculation grilles item 8a (right-hand)
and 8b (left-hand) in the apertures on each side of the
chimney. The grilles are marked with two arrows and
should be fitted with one arrow pointing upwards and
the other toward the front.
12c
•
When the hood is used in the recirculation mode ensure
that the grilles are properly secured to the recirculation
extension spigot item 14.1.
8
Download from Www.Somanuals.com. All Manuals Search And Download.
Electrical Connections
THIS APPLIANCE MUST BE EARTHED
Electrical Requirements
Any permanent electrical installation must comply with
the latest I.E.E. Regulations and local Electricity Board
regulations. For your own safety this should be under-
taken by a qualified electrician e.g. your local Electricity
Board,or a contractor who is on the roll of the National
Inspection Council for Electrical Installation Contracting
(NICEIC).
Electrical Connection
Before connecting to the mains supply ensure that the
mains voltage corresponds to the voltage on the rating
plate inside the cooker hood.
Remove the grease filters (see paragraph Maintenance)
being sure that the connector of the feeding cable is
correctly inserted in the socket placed on the side of
the fan.
This appliance is fitted with a 3 core mains cable and
must be permanently connected to the electricity supply
via a double-pole switch having 3mm minimum contact
gap on each pole.A Switched Fuse Connection Unit to
BS1363 Part 4, fitted with a 3 Amp fuse, is a recom-
mended mains supply connection accessory to ensure
compliance with the Safety Requirements applicable to
fixed wiring instructions.
This appliance conforms to BS 800: 1988 and EEC Di-
rective No. 78 308 regarding suppression of radio and
television interference.
9
Download from Www.Somanuals.com. All Manuals Search And Download.
Using the cooker hood
The cooker hood is designed to extract unpleasant
odours from the kitchen, it will not extract steam.
The appliance can be installed to recirculate or extract
contaminated air.
Cooker Hood Controls
The cooker hood functions are controlled by four push
button switches located centrally in the control fascia.
L
Turns the worktop lighting On and Off
L
V1 Motor ON/OFF switch. Depress to turn the
extractor motor on at a LOW speed, to ensure
that light cooking vapours are silently extracted.
V2 Medium speed,suitable for general use. This speed
provides an optimum treated air flow to noise level
ratio.
V3 Maximum speed, used to extract intensive levels
V1
V2
V3
of cooking vapour emissions.
To Operate
Select the required fan speed and light if required.
Recirculation
In the recirculation mode the contaminated air enters
the cooker hood through the grease filters. The air is
cleaned by passing through the charcoal filters before
being passed back into the kitchen through the grilles in
either side of the chimney stack.
Extraction
In the extraction mode the contaminated air enters the
cooker hood passing through the grease filters and is
passed out through the ducting into the atmosphere.
To obtain the best performance when cooking it is advis-
able to switch the cooker hood on for a few minutes
before you start cooking and leave it running for about
15 minutes after finishing.
When used in the ducting mode the charcoal
filters are not required.
Never do flambé cooking under this cooker
hood.
Never leave frying pans unattended during
use, as over-heated fats and oils can catch fire.
Do not leave naked flames under the cooker
hood.
Ensure heating areas on your hob are covered
with pots and pans when using the hob and
cooker hood simultaneously.
10
Download from Www.Somanuals.com. All Manuals Search And Download.
Maintenance and Cleaning
Before carrying out any maintenance or lean-
ing isolate the cooker hood from the mains
supply.
The cooker hood must be kept clean, as a
build up of grease or fat can be a fire hazard.
External cleaning
Wipe the cooker hood frequently with warm soapy water
using a mild detergent.
Never use scouring pads or abrasive cleaners.
Never use excessive amounts of water when
cleaning particularly around the control panel.
Grease Filters
The Grease Filters absorb grease and dust during cooking
to help keep the cooker hood clean inside,and should be
cleaned approximately once every two month or more
often if the hood is used for more than 3 hours a day.
Remove the Grease Filters one
at a time by:
Supporting them with one hand and turning the safety knobs
(pull and turn)
.
The Grease Filters should be washed, by hand, in mild
soapy water or in a dishwasher. Allow to dry completely
before replacing.
Replace them and fix them using the safety knobs pro-
vided (pull and turn).
11
Download from Www.Somanuals.com. All Manuals Search And Download.
Before carrying out any maintenance or
cleaning isolate the cooker hood from the
mains supply.
Charcoal Filters
In the recirculation mode the charcoal filters absorb
smells and unwanted odours.
The charcoal filters cannot be cleaned, we recommend
they should be replaced approximately every three
months or more often if the hood is used for more
than three hours per day.
To Remove/Replace the Char-
coal Filters
•
•
First remove the Grease Filters.
Remove the saturated activated charcoal filter by releasing
the fixing hooks as illustrated.
•
Position the new charcoal filter in the position marked
and while holding the filter replace the fixing hooks as
illustrated
This appliance can be a possible fire hazard if
the grease and charcoal filters are not cleaned
and replaced as recommended.
Changing the Halogen Lamp
•
•
•
Unscrew the two screws to release the metal sur-
round.
Remove the lamp from the holder by pulling the lamp
downwards.
Replace the lamp with a new one of the same type, mak-
ing sure that you insert the two pins properly into the
housings on the lamp holder.
•
Replace the Support, fixing it in place with the two screws
removed as above.
Replacement filters and light bulbs can be ob-
tained from your local Service Force Centre.
12
Download from Www.Somanuals.com. All Manuals Search And Download.
Something notWorking
If the appliance is not working correctly, please carry out the following checks, before contacting your local Service
Force agent.
IMPORTANT:If you call out an engineer to a fault listed below, or to repair a fault caused by incorrect use or instal-
lation, a charge will be made even if the appliance is under guarantee.
Symptom
Solution
The cooker hood will not start
•
•
Check the hood is connected to the electricity supply.
Make sure the switch is in the ‘ON’ position.
The cooker hood is not working effectively
•
•
•
Check that the fan speed is set high enough for the task
Ensure the grease filter is clean.
Ensure the kitchen is adequately vented to allow the entry
of fresh air.
•
•
If set up for recirculation, check that the charcoal filter is
still effective.
If set up for extraction,check that the ducting and outlets
are not blocked.
The cooker hood has switched off during
operation
•
•
The safety cut-out device has been tripped.
Tum off the hob and then wait for the device to reset.
Repairs and After Sales Service
In the event of your appliance requiring service, or if you
wish to purchase spare parts, please contact our extended
warranty administrators by telephoning:
0870 01 07887
They will give you details for your local Service Force
Centre.
Before calling out an engineer,please ensure you have read the
details under the heading “Something NotWorking”.
Your appliance is covered by a 3 year parts and labour
guarantee (see separate details given at point of sale). Please
retain your purchase receipt safely for the service engineer to
verify the purchase details.
When you contact the Service Force Centre you will need to
give the following details:
1. Your name, address and post code
2. Your telephone number
3. Clear and concise details of fault
4. The model and serial number of the appliance (found on
the rating plate located near the motor inside the hood
- see picture)
5. The purchase date.
Please note that a valid purchase receipt is required for in-
guarantee service calls.
13
Download from Www.Somanuals.com. All Manuals Search And Download.
Spare parts
This product should be serviced by any authorised service
engineer; and only genuine spare parts should be used.
Under no circumstances should you attempt to repair the
hob yourself.
Repairs carried out by inexperienced persons may cause
injury or serious malfunctioning. Contact our extended
warranty administrators on
0870 01 07887
who will give you details for your Service Force repair agent.
Always insist on genuine spare parts.
Rating Plate
14
Download from Www.Somanuals.com. All Manuals Search And Download.
Download from Www.Somanuals.com. All Manuals Search And Download.
John Lewis Partnership
171 Victoria Street
London SW1E 5NN
436003485_02 - 060822
0806
Download from Www.Somanuals.com. All Manuals Search And Download.
|