45613
Wireless Lighting Control
3D-iwmaymer
Switch Kit
®
Z-Wave Certified
nload from Www.Somanuals.com. All Manuals Search And Downl
Wireless Lighting Control
The auxiliary switch is not Z-Wave enabled and does not
directly control electrical loads. It must be used with a
compatible Z-Wave enabled, 3-wire switch in three-way
installations where a light is controlled from 2 locations
such as the top and bottom of a staircase. This switch
communicates with the Z-Wave enabled switch, providing
manual On/Off/Dim control of the connected lighting (through
the Z-Wave enabled switch) and synchronization of the
lighting status (On/Off/Dim level) between the two switches.
CAUTION
This device is intended for installation in accordance
with the National Electric Code and local regulations
in the United States, or the Canadian Electrical Code
and local regulations in Canada. If you are unsure or
uncomfortable about performing this installation
consult a qualified electrician.
This dimmer is designed for use only with permanently
installed incandescent lighting fixtures. Do not use it to
control fluorescent lighting, transformer supplied lighting/
appliances, motorized appliances or receptacles. The
incandescent lighting controlled by this dimmer must not
exceed a total of 500 watts.
There are no user serviceable
parts in this unit.
Dimmer switch
LED light
nload from Www.Somanuals.com. All ManuaAlsiSr egaarcphsAwnditDchownl
WARNING
RISK OF FIRE
RISK OF ELECTRICAL SHOCK
RISK OF BURNS
Controlling Appliances:
Exercise extreme caution when using Z-Wave devices to control
appliances. Operation of the Z-Wave device may be in a different
room than the controlled appliance, also an unintentional activation
may occur if the wrong button on the remote is pressed. Z-Wave
devices may automatically be powered on due to timed event
programming. Depending upon the appliance, these unattended
or unintentional operations could possibly result in a hazardous
condition. For these reasons, we recommend the following:
1. Assign Z-Wave controlled appliances to device numbers
10 – 18 on the GE Z-Wave remote. The likelihood of
unintentionally turning on the appliance will be reduced
significantly because the “Shift” button will need to be
pressed before pressing device numbers 10-18.
2. Z-Wave devices controlling appliances should be removed
from “All” control setting. Instructions on how to do this
are included in the manual for your GE Z-Wave remote.
3. Do Not include Z-Wave devices in Groups or Scenes if they
control appliances.
4. Do Not use Z-Wave devices to control electric heaters or
any other appliances which may present a hazardous
condition due to unattended or unintentional or automatic
power on control.
5. Double check programs for accuracy before using them.
nload from Www.Somanuals.com. All Manuals Search And Downl
Wireless Range
This device complies with the Z-Wave standard of open-
air, line of sight transmission distances of 65 feet. Actual
performance in a home depends on the number of walls
between the remote controller and the destination device,
the type of construction and the number of Z-Wave enabled
devices installed in the control network.
GE Z-Wave network
Every Z-Wave enabled device acts as a signal repeater and
multiple devices result in more possible transmission routes
which helps eliminate “RF dead-spots”.
Things to consider regarding RF range:
- Each wall or obstacle (i.e.: refrigerator, big screen TV, etc.)
between the remote or a Z-Wave device and the destination
device will reduce the maximum range of 100 feet by
approximately 25-30%.
- Brick, tile or concrete walls block more of the RF signal than
walls made of wooden studs and plasterboard (drywall).
- Wall mounted Z-Wave devices installed in metal junction
boxes will suffer a significant loss of range (approximately
20%) since the metal box blocks a large part of the RF signal.
nload from Www.Somanuals.com. All Manuals Search And Downl
Effects of Home Construction on Wireless Range Between
Z-Wave Enabled Devices.
Note: The distances shown in the table below are typical
examples. Actual performance in your home will vary.
From the Remote (or repeating Z-Wave module) to
destination device:
Type of Construction
Wood Frame
w/Drywall
Brick, Tile or
Concrete
Plastic
Metal
Plastic
Metal
J-Boxes* J-Boxes J-Boxes* J-Boxes
**
0
100’
80’
100’
80’
Number
of Walls or
Obstacles
1
2
70’
49’
56’
39’
60’
36’
48’
29’
3
34’
27’
21’
17’
* For Plug-in Modules or In-Wall Devices Installed in Plastic Junction
Boxes
** Line of Sight / no obstructions
nload from Www.Somanuals.com. All Manuals Search And Downl
Please Note: Z-Wave home control networks are designed to work
properly alongside 802.11 wireless computer networks, Bluetooth®
and other 2.4GHz or 5.8GHz devices. Some baby cams, wireless video
devices and older cordless phones using the 900MHz frequency range
may cause interference and limit Z-Wave functionality. Many 900MHz
products have a switch to select channel “A” or “B”. You may find that
one of these channels will cause less interference than the other.
IMPORTANT NOTE ABOUT 3-WAY CIRCUITS
The term “3-way circuit” refers to a circuit with two
switches and one load (light) like you find at the top and
bottom of a stairway. There are many ways to physically
wire a 3-way circuit and it is important to understand how
the circuit you wish to upgrade to Z-Wave control is wired.
Below is a description of a typical 3-way circuit.
One of the ways to wire a two-switch/one-load circuit is
to route the incoming power through the first switch, then
to the second switch and then to the load. Although very
common and by no means a standard, it is the easiest
to convert to Z-Wave control. With this type of circuit,
Switch 1 is replaced by the Z-Wave auxiliary switch and
Switch 2 is replaced with the primary Z-Wave dimmer
switch. The auxiliary switch does not actually control
the power; instead, it sends a momentary voltage signal
through the traveler wire to the primary switch which in
turn, controls the power to the load. In the configuration
shown, if the two Z-Wave switches are reversed, Z-Wave
Dimmer Switch will not be able to control the load without
additional wiring.
nload from Www.Somanuals.com. All Manuals Search And Downl
Typical 3-way circuit
Black
Black
Black
Colored(NOT GREEN)
Switch 1
Switch 2
White
Correct switch position
Z-Wave
Auxiliary
Z-Wave
Primary
Incorrect switch position
Z-Wave
Primary
Z-Wave
Auxiliary
Refer to the wiring diagram for wiring details
nload from Www.Somanuals.com. All Manuals Search And Downl
IMPORTANT NOTE ABOUT 3-WAY CIRCUITS CONT.
The yellow wire from the 45607 must only be connected to
the yellow wire of the 45610 via the traveler wire. The dimmer
switch will fail if the yellow wire is connected to Line (Hot),
Neutral or Ground. It must be insulated properly if it is not used.
Please consult an electrician if you have trouble identifying the
type of wiring circuit you wish to convert or if you do not feel
confident in your ability to convert the circuit to Z-Wave control.
INSTALLATION
This dimmer switch is designed for use with permanently
installed incandescent lighting only and may be used in new
installations or to replace an existing wall switch. A wall plate
is not included. You may be able to re-use your existing wall
plate if you are replacing a standard decorator style switch
or dimmer. If this is a new installation or your existing wall
plate can not be used, we recommend the use of a mid-sized,
decorator style wall plate. These are available at most home
centers or hardware stores.
It can be used by itself or in three-way installations where a
light is controlled from 2 locations such as the top and bottom
of a staircase. It is also compatible with four-way installations
(three switches & one light) if a second auxiliary switch is used.
Please note: The 45610 Auxiliary Switch must be used with the
45607 Dimmer Switch in three-way installations. Two Auxiliary
switches must be used in four-way installations.
nload from Www.Somanuals.com. All Manuals Search And Downl
Wiring Digram
Hot (Black)
Black
Black
Yellow
Yellow
Blue
Dimmer
Switch
Auxiliary
Switch
One Auxiliary
Switch for
3-way
White
500W
installation.
Green
Green
Ground
(Green)
Neutral
(White)
Hot (Black)
Black
Yellow
45610
Auxiliary
Switch
Two Auxiliary
Switches for 4-way
installation.
Green
Up to 2 Auxiliary switches may be used to
create a 4-way installation
nload from Www.Somanuals.com. All Manuals Search And Downl
Single, Dual and Triple Gang Boxes
The metal plate surrounding the switch assembly is a heat sink.
The maximum load rating (500W) is provided when installed in a
single gang box with the full heat sink. Multiple 45607 Dimmer
Switches may be installed in dual or triple gang boxes and, if
necessary, one or both sides of the heat sink may be removed
by bending it at the score lines. There is a corresponding
reduction in the switch’s load rating when ganged. DO NOT
exceed the following loads:
Dimmer Rating Number of Dimmers
Heat Sink
500W
400W
300W
One Dimmer in a Single
Gang Box
Full
Two Dimmers in a Double
Gang Box
One side removed
Bothsidesremoved
Three Dimmers in a Triple
Gang Box
nload from Www.Somanuals.com. All Manuals Search And Downl
Traveler
(Colored not green)
White
(Neutral)
Yellow
(Traveler)
Blue
(Load)
Black
Black
(HOT or Load)
(HOT or Load)
Green
(Ground)
nload from Www.Somanuals.com. All Manuals Search And Downl
45607
Traveler
(color not green)
Green
(grounded)
Yellow
(traveler)
Black
(Hot)
Red/White
(Hot)
nload from Www.Somanuals.com. All Manuals Search And Downl
45610
WARNING
SHOCK HAZARD!
Turn OFF the power to the branch circuit at the circuit
breaker in your electrical service panel. Ensure power
is OFF before you install this device. All wiring connections
must be made with the POWER OFF to avoid personal
injury and/or damage to the switch.
1. Shut off power to the circuit at fuse box or circuit breaker.
2. Remove wall plate. !Warning: Verify power is OFF to switch
before continuing.
3. Remove the switch mounting screws.
4. Carefully remove the switch from the switch box. DO NOT
disconnect the wires.
5. Identify the wiring in the box and decide if this will be the
location for the Auxiliary Switch or the Dimmer Switch.
6. Mark the wiring so it can be identified properly later.
7. Disconnect the wiring and remove the switch.
8. Install either the Auxiliary or Dimmer Switch as shown in the
wiring diagram.
9. Insert the new switch into the switch box being careful not to
pinch or crush wires.
10. Repeat Steps 2 through 9 for the second switch.
11. Reapply power to the circuit at fuse box or circuit breaker and
test the system.
Observe Important Wiring Information
Always follow the recommended wire strip lengths and wiring
combinations when making wiring connections. Important:
The wire connectors included with this dimmer are intended to
only be used with copper wire. Consult a qualified electrician
if you have aluminum wiring.
nload from Www.Somanuals.com. All Manuals Search And Downl
Instructions:
1. Strip insulation 3/8” for 12 or 14 AWG wire. Strip insulation
7/16” for 16 or 18 AWG wire.
2. Hold stripped ends together in parallel and align any frayed
strands (do not twist wires).
3. Push wires firmly into connector. Twist connector clockwise
with fingers until tight. Pull wires to check for tightness.
Wire Connector / Combination Chart
One #14 w/one-to-four #16 or #18
One #12 w/one-to-three #14 or #16 or #18
Two #14 w/one-to-three #16 or #18
Two #12 w/one or two #14 or #16 or #18
You should now be able to use the rocker to manually turn
On/Off/Brighten the connected lighting.
Use your primary controller to include the dimmer switch in
the home control network after the dimmer switch is wired as
shown in the above diagram. It can then be added to groups
and/or lighting scenes and managed remotely to control
the On/Off status and brightness level of the connected
incandescent lighting.
Air Gap Switch
The 45607 has an air gap switch on the lower left side (see
diagram for location) to completely disconnect power to the
load. Pull the air gap switch OUT to disconnect the power and
push it all the way back in for normal operation. The air gap
switch must be all the way in for the dimmer to function and
control the lighting.
nload from Www.Somanuals.com. All Manuals Search And Downl
Key Features
- Controls one light from two locations
- Remote On/Off/Brightness control via the Z-Wave controller/
network
- Manual On/Off/Brightness control with the front panel rocker
- LED indicates primary switch location in a dark room
- Adjustable Dim rates
BASIC OPERATION
Remote Control
GE Z-Wave remotes provide control of an Individual device,
Groups of devices and Scenes. Other brands of Z-Wave
Certified remotes may not offer as much flexibility in how you
can set up your lighting control network. Please refer to your
remote control’s instructions for details on its capabilities and
instructions for adding and controlling devices.
Manual Control
Both switches allow the user to turn ON/OFF and control the
brightness level of the connected incandescent lighting.
- To turn the connected lighting ON: Tap the top of the rocker.
- To turn the connected lighting OFF: Tap the bottom of the
rocker.
- To brighten the connected lighting: Press and hold the top of
the rocker; release when desired level is achieved
- To dim the connected lighting: Press and hold the bottom of
the rocker; release when desired level is achieved. Please
note: pressing and holding the rocker until the light intensity
is at the minimum setting does not turn the power OFF; you
nload from Www.Somanuals.com. All Manuals Search And Downl
must still tap (press & release) the bottom of the rocker to
turn the power OFF.
- When OFF, pressing and holding the bottom of the rocker will
cause the lighting to go to the minimum dim level.
Program your light Switch (The model 45607 primary switch
must be used to include or exclude the dimmer switch from
the Z-Wave home control network.)
- Refer to the instructions for your primary controller to access
the network setup function and include or exclude devices.
- When prompted by your primary controller, tap the top or
bottom of the rocker.
- The primary controller should indicate that the action
was successful. If the controller indicates the action was
unsuccessful, please repeat the procedure.
- Once the dimmer switch is part of the network, the same
basic procedure is used to add the dimmer switch to groups
& scenes or change advanced functions. Refer to the
primary controller’s instructions for details.
Please Note: After a power failure, the 45607 dimmer switch
returns to its last used On/Off/Dim state.
LED Indicator – Primary Switch Only
- The LED will be lit when the connected lighting is OFF.
- This is the factory default setting and can be changed if your
primary controller supports the node configuration function
(see Advanced Operation below).
nload from Www.Somanuals.com. All Manuals Search And Downl
ADVANCED OPERATION
The following Advanced Operation parameters require that you
have an advanced controller like the 45601 Advanced remote.
Advanced remotes from other manufacturers may also be able
to change these settings; however, basic remotes do not have
this capability.
All On/All Off
Depending upon your primary controller, the 45607 dimmer
switch can be set to respond to ALL ON and ALL OFF
commands in up to four different ways. Some controllers may
not be able to change the response from its default setting.
Please refer to your controller’s instructions for information on
whether or not it supports the configuration function and if so,
how to change this setting.
The four possible responses are:
1. It will respond to ALL ON and the ALL OFF command (default).
2. It will not respond to ALL ON or ALL OFF commands.
3. It will respond to the ALL OFF command but will not respond to
the ALL ON command.
4. It will respond to the ALL ON command but will not respond to
the ALL OFF command.
LED Light
When shipped from the factory, the LED on the 45607 is set to
turn ON when the connected light is turned OFF. This allows the
LED to indicate the switch’s location in a dark room. To make
the LED turn ON when the light is turned ON, change parameter
3’s value to “1”.
nload from Www.Somanuals.com. All Manuals Search And Downl
- Parameter No: 3
- Length: 1 Byte
- Valid Values = 0 or 1 (default 0)
Invert Switch
If the dimmer switch is accidentally installed upside down with
“On” at the bottom and “Off” at the top, the default On/Off
rocker settings can be reversed by changing parameter 4’s
value to “1”.
- Parameter No: 4
- Length: 1 Byte
- Valid Values = 0 or 1 (default 0)
Dim Rate Adjustments
Both the number of steps (or levels) that the dimmer will change
and the timing of the steps can be modified to suit personal
preferences. The timing of the steps can be adjusted in 10
millisecond intervals. As an example, the default setting for
parameter 8 is “3”. This means that the lighting level will change
every 30 milliseconds when the Dim Command is received. A
value of 255 would mean that the level would change every
2.55 seconds. Combined, the two parameters allow dim rate
adjustments from 10 milliseconds to 4.2 minutes to go
from maximum-to-minimum or minimum-to-maximum
brightness levels.
1. When Receiving a Z-Wave Dim Command
- Parameter 7 (number of steps or levels)
- Parameter 8 (timing of the steps)
- Length: 1 Byte
nload from Www.Somanuals.com. All Manuals Search And Downl
- Valid Values:
Parameter 7 (default = 1) Valid Values: 1-99
Parameter 8 (default = 3) Valid Values: 1-255
2. Manual Control Dimming (pressing the Dimmer’s rocker)
- Parameter 9 (number of steps or levels)
- Parameter 10 (timing of the steps)
- Length: 1 Byte
- Valid Values:
Parameter 9 (default = 1) Valid Values: 1-99
Parameter 10 (default = 3) Valid Values: 1-255
3. When Receiving an All-On or All-Off Command
- Parameter 11 (number of steps or levels)
- Parameter 12 (timing of the steps)
- Length: 1 Byte
- Valid Values:
Parameter 11 (default = 1) Valid Values: 1-99
Parameter 12 (default = 3) Valid Values: 1-255
Ignore Start Level When Receiving Dim Commands
Please note: Every “Dim” command includes a start level
embedded in it.
The 45607 can be set to ignore the start level that is part of the
dim command. Setting parameter 5 to a value of 0 will cause
the 45607 to dim or brighten from the start level embedded in
the command.
- Parameter No: 5
- Length: 1 Byte
nload from Www.Somanuals.com. All Manuals Search And Downl
- Valid Values = 0 or 1 (default 1)
Restoring Factory Defaults
All Configuration Parameters can all be restored to their factory
default settings by using your master controller to reset the device.
Interoperability with Z-Wave™ Devices
A Z-Wave™ network can integrate devices of various classes, and
these devices can be made by different manufacturers. Although
every Z-Wave certified product is designed to work with all other
Z-Wave certified products, your controller must include the
appropriate device classifications in order to control non-lighting
Z-wave devices. As an example, the GE 45600 basic remote is
designed only for controlling Z-Wave devices using the lighting
control classification. The GE 45601 deluxe remote with LCD readout
can control other Z-Wave certified devices like thermostats as well
as lighting.
WARRANTY
JASCO Products warrants this product to be free from
manufacturing defects for a period of two years from the original
date of consumer purchase. This warranty is limited to the repair
or replacement of this product only and does not extend to
consequential or incidental damage to other products that may be
used with this product. This warranty is in lieu of all other warranties,
expressed or implied. Some states do not allow limitations on how
long an implied warranty lasts or permit the exclusion or limitation
of incidental or consequential damage, so the above limitations may
not apply to you. This warranty gives you specific rights, and you
may also have other rights which vary from state to state. Please
contact Customer Service at 800-654-8483 (option 4) between
the unit should prove defective within the warranty period or
visit easyzwave.com
JASCO Products Company
Building B
nlo1a0dEfrMoemmWoriwalwR.dS. OomklaahnoumaalsC.citoy,mO.KA73ll1M14anuals Search And Downl
FCC
U2Z45606-7
The Federal Communication Commission Radio Frequency Interference
Statement includes the following paragraph:
The equipment has been tested and found to comply with the limits
for a Class B Digital Device, pursuant to part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment uses, generates
and can radiate radio frequency energy and, if not installed and used in
accordance with the instruction, may cause harmful interference to radio
communication. However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct
the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna
- Increase the separation between the equipment and receiver
- Connect the equipment into an outlet on a circuit different from
that to which the receiver is connected
- Consult the dealer or an experienced radio/TV technician for help
Operation is subject to the following two conditions:
- This device may not cause interference
- This device must accept any interference, including interference
that may cause undesired operation of the device.
Important Note: To comply with the FCC RF exposure compliance
requirements, no change to the antenna or the device is permitted. Any
change to the antenna or the device could result in the device exceeding
the RF exposure requirements and void user’s authority to operate the
device.
Compliance with IC Rules and Regulations
IC: 6924A-45606A7
Jasco Products Company
Model: 45607
nload from Www.Somanuals.com. All Manuals Search And Downl
This Class B digital device complies with Canadian ICES-003.
SPECIFICATIONS
Power: 120 VAC, 60 Hz.
Signal (Frequency): 908.42 MHz.
Minimum Load: 40W, incandescent lamps only.
Maximum Load: 500W, incandescent lamps only.
Range: Up to 65 feet line of sight between the Wireless Controller and
the closest Z-Wave receiver module.
Operating Temperature Range: 32-104° F (0-40° C)
For indoor use only.
Specifications subject to change without notice due to continuing
product improvement
Z-Wave is a registered US trademark of Zensys A/S
nload from Www.Somanuals.com. All Manuals Search And Downl
is a registered trademark of
General Electric Company
and is used under license to
Jasco Products Company LLC,
10 E Memorial Rd., Oklahoma
City, Oklahoma 73114
Made in China
Hecho en China
All brand names shown are
trademarks of their respective
owners.
Todas las marcas que aparecen
aquí son marcas registradas de
sus respectivos dueños.
nload from Www.Somanuals.com. All Manuals Search And Downl
|