Jasco Indoor Furnishings ZWAVEKIT User Manual

45613  
Wireless Lighting Control  
3D-iwmaymer  
Switch Kit  
®
Z-Wave Certified  
nload from Www.Somanuals.com. All Manuals Search And Downl  
Wireless Lighting Control  
The auxiliary switch is not Z-Wave enabled and does not  
directly control electrical loads. It must be used with a  
compatible Z-Wave enabled, 3-wire switch in three-way  
installations where a light is controlled from 2 locations  
such as the top and bottom of a staircase. This switch  
communicates with the Z-Wave enabled switch, providing  
manual On/Off/Dim control of the connected lighting (through  
the Z-Wave enabled switch) and synchronization of the  
lighting status (On/Off/Dim level) between the two switches.  
CAUTION  
This device is intended for installation in accordance  
with the National Electric Code and local regulations  
in the United States, or the Canadian Electrical Code  
and local regulations in Canada. If you are unsure or  
uncomfortable about performing this installation  
consult a qualified electrician.  
This dimmer is designed for use only with permanently  
installed incandescent lighting fixtures. Do not use it to  
control fluorescent lighting, transformer supplied lighting/  
appliances, motorized appliances or receptacles. The  
incandescent lighting controlled by this dimmer must not  
exceed a total of 500 watts.  
There are no user serviceable  
parts in this unit.  
Dimmer switch  
LED light  
nload from Www.Somanuals.com. All ManuaAlsiSr egaarcphsAwnditDchownl  
WARNING  
RISK OF FIRE  
RISK OF ELECTRICAL SHOCK  
RISK OF BURNS  
Controlling Appliances:  
Exercise extreme caution when using Z-Wave devices to control  
appliances. Operation of the Z-Wave device may be in a different  
room than the controlled appliance, also an unintentional activation  
may occur if the wrong button on the remote is pressed. Z-Wave  
devices may automatically be powered on due to timed event  
programming. Depending upon the appliance, these unattended  
or unintentional operations could possibly result in a hazardous  
condition. For these reasons, we recommend the following:  
1. Assign Z-Wave controlled appliances to device numbers  
10 – 18 on the GE Z-Wave remote. The likelihood of  
unintentionally turning on the appliance will be reduced  
significantly because the “Shift” button will need to be  
pressed before pressing device numbers 10-18.  
2. Z-Wave devices controlling appliances should be removed  
from “All” control setting. Instructions on how to do this  
are included in the manual for your GE Z-Wave remote.  
3. Do Not include Z-Wave devices in Groups or Scenes if they  
control appliances.  
4. Do Not use Z-Wave devices to control electric heaters or  
any other appliances which may present a hazardous  
condition due to unattended or unintentional or automatic  
power on control.  
5. Double check programs for accuracy before using them.  
nload from Www.Somanuals.com. All Manuals Search And Downl  
Wireless Range  
This device complies with the Z-Wave standard of open-  
air, line of sight transmission distances of 65 feet. Actual  
performance in a home depends on the number of walls  
between the remote controller and the destination device,  
the type of construction and the number of Z-Wave enabled  
devices installed in the control network.  
GE Z-Wave network  
Every Z-Wave enabled device acts as a signal repeater and  
multiple devices result in more possible transmission routes  
which helps eliminate “RF dead-spots”.  
Things to consider regarding RF range:  
- Each wall or obstacle (i.e.: refrigerator, big screen TV, etc.)  
between the remote or a Z-Wave device and the destination  
device will reduce the maximum range of 100 feet by  
approximately 25-30%.  
- Brick, tile or concrete walls block more of the RF signal than  
walls made of wooden studs and plasterboard (drywall).  
- Wall mounted Z-Wave devices installed in metal junction  
boxes will suffer a significant loss of range (approximately  
20%) since the metal box blocks a large part of the RF signal.  
nload from Www.Somanuals.com. All Manuals Search And Downl  
Effects of Home Construction on Wireless Range Between  
Z-Wave Enabled Devices.  
Note: The distances shown in the table below are typical  
examples. Actual performance in your home will vary.  
From the Remote (or repeating Z-Wave module) to  
destination device:  
Type of Construction  
Wood Frame  
w/Drywall  
Brick, Tile or  
Concrete  
Plastic  
Metal  
Plastic  
Metal  
J-Boxes* J-Boxes J-Boxes* J-Boxes  
**  
0
100’  
80’  
100’  
80’  
Number  
of Walls or  
Obstacles  
1
2
70’  
49’  
56’  
39’  
60’  
36’  
48’  
29’  
3
34’  
27’  
21’  
17’  
* For Plug-in Modules or In-Wall Devices Installed in Plastic Junction  
Boxes  
** Line of Sight / no obstructions  
nload from Www.Somanuals.com. All Manuals Search And Downl  
Please Note: Z-Wave home control networks are designed to work  
properly alongside 802.11 wireless computer networks, Bluetooth®  
and other 2.4GHz or 5.8GHz devices. Some baby cams, wireless video  
devices and older cordless phones using the 900MHz frequency range  
may cause interference and limit Z-Wave functionality. Many 900MHz  
products have a switch to select channel “A” or “B”. You may find that  
one of these channels will cause less interference than the other.  
IMPORTANT NOTE ABOUT 3-WAY CIRCUITS  
The term “3-way circuit” refers to a circuit with two  
switches and one load (light) like you find at the top and  
bottom of a stairway. There are many ways to physically  
wire a 3-way circuit and it is important to understand how  
the circuit you wish to upgrade to Z-Wave control is wired.  
Below is a description of a typical 3-way circuit.  
One of the ways to wire a two-switch/one-load circuit is  
to route the incoming power through the first switch, then  
to the second switch and then to the load. Although very  
common and by no means a standard, it is the easiest  
to convert to Z-Wave control. With this type of circuit,  
Switch 1 is replaced by the Z-Wave auxiliary switch and  
Switch 2 is replaced with the primary Z-Wave dimmer  
switch. The auxiliary switch does not actually control  
the power; instead, it sends a momentary voltage signal  
through the traveler wire to the primary switch which in  
turn, controls the power to the load. In the configuration  
shown, if the two Z-Wave switches are reversed, Z-Wave  
Dimmer Switch will not be able to control the load without  
additional wiring.  
nload from Www.Somanuals.com. All Manuals Search And Downl  
Typical 3-way circuit  
Black  
Black  
Black  
Colored(NOT GREEN)  
Switch 1  
Switch 2  
White  
Correct switch position  
Z-Wave  
Auxiliary  
Z-Wave  
Primary  
Incorrect switch position  
Z-Wave  
Primary  
Z-Wave  
Auxiliary  
Refer to the wiring diagram for wiring details  
nload from Www.Somanuals.com. All Manuals Search And Downl  
IMPORTANT NOTE ABOUT 3-WAY CIRCUITS CONT.  
The yellow wire from the 45607 must only be connected to  
the yellow wire of the 45610 via the traveler wire. The dimmer  
switch will fail if the yellow wire is connected to Line (Hot),  
Neutral or Ground. It must be insulated properly if it is not used.  
Please consult an electrician if you have trouble identifying the  
type of wiring circuit you wish to convert or if you do not feel  
confident in your ability to convert the circuit to Z-Wave control.  
INSTALLATION  
This dimmer switch is designed for use with permanently  
installed incandescent lighting only and may be used in new  
installations or to replace an existing wall switch. A wall plate  
is not included. You may be able to re-use your existing wall  
plate if you are replacing a standard decorator style switch  
or dimmer. If this is a new installation or your existing wall  
plate can not be used, we recommend the use of a mid-sized,  
decorator style wall plate. These are available at most home  
centers or hardware stores.  
It can be used by itself or in three-way installations where a  
light is controlled from 2 locations such as the top and bottom  
of a staircase. It is also compatible with four-way installations  
(three switches & one light) if a second auxiliary switch is used.  
Please note: The 45610 Auxiliary Switch must be used with the  
45607 Dimmer Switch in three-way installations. Two Auxiliary  
switches must be used in four-way installations.  
nload from Www.Somanuals.com. All Manuals Search And Downl  
Wiring Digram  
Hot (Black)  
Black  
Black  
Yellow  
Yellow  
Blue  
Dimmer  
Switch  
Auxiliary  
Switch  
One Auxiliary  
Switch for  
3-way  
White  
500W  
installation.  
Green  
Green  
Ground  
(Green)  
Neutral  
(White)  
Hot (Black)  
Black  
Yellow  
45610  
Auxiliary  
Switch  
Two Auxiliary  
Switches for 4-way  
installation.  
Green  
Up to 2 Auxiliary switches may be used to  
create a 4-way installation  
nload from Www.Somanuals.com. All Manuals Search And Downl  
Single, Dual and Triple Gang Boxes  
The metal plate surrounding the switch assembly is a heat sink.  
The maximum load rating (500W) is provided when installed in a  
single gang box with the full heat sink. Multiple 45607 Dimmer  
Switches may be installed in dual or triple gang boxes and, if  
necessary, one or both sides of the heat sink may be removed  
by bending it at the score lines. There is a corresponding  
reduction in the switch’s load rating when ganged. DO NOT  
exceed the following loads:  
Dimmer Rating Number of Dimmers  
Heat Sink  
500W  
400W  
300W  
One Dimmer in a Single  
Gang Box  
Full  
Two Dimmers in a Double  
Gang Box  
One side removed  
Bothsidesremoved  
Three Dimmers in a Triple  
Gang Box  
nload from Www.Somanuals.com. All Manuals Search And Downl  
Traveler  
(Colored not green)  
White  
(Neutral)  
Yellow  
(Traveler)  
Blue  
(Load)  
Black  
Black  
(HOT or Load)  
(HOT or Load)  
Green  
(Ground)  
nload from Www.Somanuals.com. All Manuals Search And Downl  
45607  
Traveler  
(color not green)  
Green  
(grounded)  
Yellow  
(traveler)  
Black  
(Hot)  
Red/White  
(Hot)  
nload from Www.Somanuals.com. All Manuals Search And Downl  
45610  
WARNING  
SHOCK HAZARD!  
Turn OFF the power to the branch circuit at the circuit  
breaker in your electrical service panel. Ensure power  
is OFF before you install this device. All wiring connections  
must be made with the POWER OFF to avoid personal  
injury and/or damage to the switch.  
1. Shut off power to the circuit at fuse box or circuit breaker.  
2. Remove wall plate. !Warning: Verify power is OFF to switch  
before continuing.  
3. Remove the switch mounting screws.  
4. Carefully remove the switch from the switch box. DO NOT  
disconnect the wires.  
5. Identify the wiring in the box and decide if this will be the  
location for the Auxiliary Switch or the Dimmer Switch.  
6. Mark the wiring so it can be identified properly later.  
7. Disconnect the wiring and remove the switch.  
8. Install either the Auxiliary or Dimmer Switch as shown in the  
wiring diagram.  
9. Insert the new switch into the switch box being careful not to  
pinch or crush wires.  
10. Repeat Steps 2 through 9 for the second switch.  
11. Reapply power to the circuit at fuse box or circuit breaker and  
test the system.  
Observe Important Wiring Information  
Always follow the recommended wire strip lengths and wiring  
combinations when making wiring connections. Important:  
The wire connectors included with this dimmer are intended to  
only be used with copper wire. Consult a qualified electrician  
if you have aluminum wiring.  
nload from Www.Somanuals.com. All Manuals Search And Downl  
Instructions:  
1. Strip insulation 3/8” for 12 or 14 AWG wire. Strip insulation  
7/16” for 16 or 18 AWG wire.  
2. Hold stripped ends together in parallel and align any frayed  
strands (do not twist wires).  
3. Push wires firmly into connector. Twist connector clockwise  
with fingers until tight. Pull wires to check for tightness.  
Wire Connector / Combination Chart  
One #14 w/one-to-four #16 or #18  
One #12 w/one-to-three #14 or #16 or #18  
Two #14 w/one-to-three #16 or #18  
Two #12 w/one or two #14 or #16 or #18  
You should now be able to use the rocker to manually turn  
On/Off/Brighten the connected lighting.  
Use your primary controller to include the dimmer switch in  
the home control network after the dimmer switch is wired as  
shown in the above diagram. It can then be added to groups  
and/or lighting scenes and managed remotely to control  
the On/Off status and brightness level of the connected  
incandescent lighting.  
Air Gap Switch  
The 45607 has an air gap switch on the lower left side (see  
diagram for location) to completely disconnect power to the  
load. Pull the air gap switch OUT to disconnect the power and  
push it all the way back in for normal operation. The air gap  
switch must be all the way in for the dimmer to function and  
control the lighting.  
nload from Www.Somanuals.com. All Manuals Search And Downl  
Key Features  
- Controls one light from two locations  
- Remote On/Off/Brightness control via the Z-Wave controller/  
network  
- Manual On/Off/Brightness control with the front panel rocker  
- LED indicates primary switch location in a dark room  
- Adjustable Dim rates  
BASIC OPERATION  
Remote Control  
GE Z-Wave remotes provide control of an Individual device,  
Groups of devices and Scenes. Other brands of Z-Wave  
Certified remotes may not offer as much flexibility in how you  
can set up your lighting control network. Please refer to your  
remote control’s instructions for details on its capabilities and  
instructions for adding and controlling devices.  
Manual Control  
Both switches allow the user to turn ON/OFF and control the  
brightness level of the connected incandescent lighting.  
- To turn the connected lighting ON: Tap the top of the rocker.  
- To turn the connected lighting OFF: Tap the bottom of the  
rocker.  
- To brighten the connected lighting: Press and hold the top of  
the rocker; release when desired level is achieved  
- To dim the connected lighting: Press and hold the bottom of  
the rocker; release when desired level is achieved. Please  
note: pressing and holding the rocker until the light intensity  
is at the minimum setting does not turn the power OFF; you  
nload from Www.Somanuals.com. All Manuals Search And Downl  
must still tap (press & release) the bottom of the rocker to  
turn the power OFF.  
- When OFF, pressing and holding the bottom of the rocker will  
cause the lighting to go to the minimum dim level.  
Program your light Switch (The model 45607 primary switch  
must be used to include or exclude the dimmer switch from  
the Z-Wave home control network.)  
- Refer to the instructions for your primary controller to access  
the network setup function and include or exclude devices.  
- When prompted by your primary controller, tap the top or  
bottom of the rocker.  
- The primary controller should indicate that the action  
was successful. If the controller indicates the action was  
unsuccessful, please repeat the procedure.  
- Once the dimmer switch is part of the network, the same  
basic procedure is used to add the dimmer switch to groups  
& scenes or change advanced functions. Refer to the  
primary controller’s instructions for details.  
Please Note: After a power failure, the 45607 dimmer switch  
returns to its last used On/Off/Dim state.  
LED Indicator – Primary Switch Only  
- The LED will be lit when the connected lighting is OFF.  
- This is the factory default setting and can be changed if your  
primary controller supports the node configuration function  
(see Advanced Operation below).  
nload from Www.Somanuals.com. All Manuals Search And Downl  
ADVANCED OPERATION  
The following Advanced Operation parameters require that you  
have an advanced controller like the 45601 Advanced remote.  
Advanced remotes from other manufacturers may also be able  
to change these settings; however, basic remotes do not have  
this capability.  
All On/All Off  
Depending upon your primary controller, the 45607 dimmer  
switch can be set to respond to ALL ON and ALL OFF  
commands in up to four different ways. Some controllers may  
not be able to change the response from its default setting.  
Please refer to your controller’s instructions for information on  
whether or not it supports the configuration function and if so,  
how to change this setting.  
The four possible responses are:  
1. It will respond to ALL ON and the ALL OFF command (default).  
2. It will not respond to ALL ON or ALL OFF commands.  
3. It will respond to the ALL OFF command but will not respond to  
the ALL ON command.  
4. It will respond to the ALL ON command but will not respond to  
the ALL OFF command.  
LED Light  
When shipped from the factory, the LED on the 45607 is set to  
turn ON when the connected light is turned OFF. This allows the  
LED to indicate the switch’s location in a dark room. To make  
the LED turn ON when the light is turned ON, change parameter  
3’s value to “1”.  
nload from Www.Somanuals.com. All Manuals Search And Downl  
- Parameter No: 3  
- Length: 1 Byte  
- Valid Values = 0 or 1 (default 0)  
Invert Switch  
If the dimmer switch is accidentally installed upside down with  
“On” at the bottom and “Off” at the top, the default On/Off  
rocker settings can be reversed by changing parameter 4’s  
value to “1”.  
- Parameter No: 4  
- Length: 1 Byte  
- Valid Values = 0 or 1 (default 0)  
Dim Rate Adjustments  
Both the number of steps (or levels) that the dimmer will change  
and the timing of the steps can be modified to suit personal  
preferences. The timing of the steps can be adjusted in 10  
millisecond intervals. As an example, the default setting for  
parameter 8 is “3”. This means that the lighting level will change  
every 30 milliseconds when the Dim Command is received. A  
value of 255 would mean that the level would change every  
2.55 seconds. Combined, the two parameters allow dim rate  
adjustments from 10 milliseconds to 4.2 minutes to go  
from maximum-to-minimum or minimum-to-maximum  
brightness levels.  
1. When Receiving a Z-Wave Dim Command  
- Parameter 7 (number of steps or levels)  
- Parameter 8 (timing of the steps)  
- Length: 1 Byte  
nload from Www.Somanuals.com. All Manuals Search And Downl  
- Valid Values:  
Parameter 7 (default = 1) Valid Values: 1-99  
Parameter 8 (default = 3) Valid Values: 1-255  
2. Manual Control Dimming (pressing the Dimmer’s rocker)  
- Parameter 9 (number of steps or levels)  
- Parameter 10 (timing of the steps)  
- Length: 1 Byte  
- Valid Values:  
Parameter 9 (default = 1) Valid Values: 1-99  
Parameter 10 (default = 3) Valid Values: 1-255  
3. When Receiving an All-On or All-Off Command  
- Parameter 11 (number of steps or levels)  
- Parameter 12 (timing of the steps)  
- Length: 1 Byte  
- Valid Values:  
Parameter 11 (default = 1) Valid Values: 1-99  
Parameter 12 (default = 3) Valid Values: 1-255  
Ignore Start Level When Receiving Dim Commands  
Please note: Every “Dim” command includes a start level  
embedded in it.  
The 45607 can be set to ignore the start level that is part of the  
dim command. Setting parameter 5 to a value of 0 will cause  
the 45607 to dim or brighten from the start level embedded in  
the command.  
- Parameter No: 5  
- Length: 1 Byte  
nload from Www.Somanuals.com. All Manuals Search And Downl  
- Valid Values = 0 or 1 (default 1)  
Restoring Factory Defaults  
All Configuration Parameters can all be restored to their factory  
default settings by using your master controller to reset the device.  
Interoperability with Z-WaveDevices  
A Z-Wavenetwork can integrate devices of various classes, and  
these devices can be made by different manufacturers. Although  
every Z-Wave certified product is designed to work with all other  
Z-Wave certified products, your controller must include the  
appropriate device classifications in order to control non-lighting  
Z-wave devices. As an example, the GE 45600 basic remote is  
designed only for controlling Z-Wave devices using the lighting  
control classification. The GE 45601 deluxe remote with LCD readout  
can control other Z-Wave certified devices like thermostats as well  
as lighting.  
WARRANTY  
JASCO Products warrants this product to be free from  
manufacturing defects for a period of two years from the original  
date of consumer purchase. This warranty is limited to the repair  
or replacement of this product only and does not extend to  
consequential or incidental damage to other products that may be  
used with this product. This warranty is in lieu of all other warranties,  
expressed or implied. Some states do not allow limitations on how  
long an implied warranty lasts or permit the exclusion or limitation  
of incidental or consequential damage, so the above limitations may  
not apply to you. This warranty gives you specific rights, and you  
may also have other rights which vary from state to state. Please  
contact Customer Service at 800-654-8483 (option 4) between  
the unit should prove defective within the warranty period or  
visit easyzwave.com  
JASCO Products Company  
Building B  
nlo1a0dEfrMoemmWoriwalwR.dS. OomklaahnoumaalsC.citoy,mO.KA73ll1M14anuals Search And Downl  
FCC  
U2Z45606-7  
The Federal Communication Commission Radio Frequency Interference  
Statement includes the following paragraph:  
The equipment has been tested and found to comply with the limits  
for a Class B Digital Device, pursuant to part 15 of the FCC Rules. These  
limits are designed to provide reasonable protection against harmful  
interference in a residential installation. This equipment uses, generates  
and can radiate radio frequency energy and, if not installed and used in  
accordance with the instruction, may cause harmful interference to radio  
communication. However, there is no guarantee that interference will not  
occur in a particular installation. If this equipment does cause harmful  
interference to radio or television reception, which can be determined by  
turning the equipment off and on, the user is encouraged to try to correct  
the interference by one or more of the following measures:  
- Reorient or relocate the receiving antenna  
- Increase the separation between the equipment and receiver  
- Connect the equipment into an outlet on a circuit different from  
that to which the receiver is connected  
- Consult the dealer or an experienced radio/TV technician for help  
Operation is subject to the following two conditions:  
- This device may not cause interference  
- This device must accept any interference, including interference  
that may cause undesired operation of the device.  
Important Note: To comply with the FCC RF exposure compliance  
requirements, no change to the antenna or the device is permitted. Any  
change to the antenna or the device could result in the device exceeding  
the RF exposure requirements and void user’s authority to operate the  
device.  
Compliance with IC Rules and Regulations  
IC: 6924A-45606A7  
Jasco Products Company  
Model: 45607  
nload from Www.Somanuals.com. All Manuals Search And Downl  
This Class B digital device complies with Canadian ICES-003.  
SPECIFICATIONS  
Power: 120 VAC, 60 Hz.  
Signal (Frequency): 908.42 MHz.  
Minimum Load: 40W, incandescent lamps only.  
Maximum Load: 500W, incandescent lamps only.  
Range: Up to 65 feet line of sight between the Wireless Controller and  
the closest Z-Wave receiver module.  
Operating Temperature Range: 32-104° F (0-40° C)  
For indoor use only.  
Specifications subject to change without notice due to continuing  
product improvement  
Z-Wave is a registered US trademark of Zensys A/S  
nload from Www.Somanuals.com. All Manuals Search And Downl  
is a registered trademark of  
General Electric Company  
and is used under license to  
Jasco Products Company LLC,  
10 E Memorial Rd., Oklahoma  
City, Oklahoma 73114  
Made in China  
Hecho en China  
All brand names shown are  
trademarks of their respective  
owners.  
Todas las marcas que aparecen  
aquí son marcas registradas de  
sus respectivos dueños.  
nload from Www.Somanuals.com. All Manuals Search And Downl  

Insignia Video Game Furniture NS 13SGAM User Manual
Invacare Mobility Aid M6TM User Manual
Jabra Bluetooth Headset GN1215 User Manual
Jasco Universal Remote RM24970 User Manual
Jenn Air Food Warmer ELECTRIC WARMING User Manual
JL Audio Car Speaker SB D TRKEXT 10W1 User Manual
JL Audio Car Stereo System C2 600 User Manual
Johnson Controls Door CKT 240 User Manual
Kenwood Speaker KFC W2511 User Manual
Kodak Camcorder 1455013 User Manual