2 WALL  
Specifications _________________________________________________________________________ 2  
Rough-in Reference ____________________________________________________________________ 3  
Component Identification ________________________________________________________________ 4  
Base Installation _______________________________________________________________________ 5-7  
Tower and Glass Panels Installation ________________________________________________________ 8-12  
3 WALL  
Specifications _________________________________________________________________________ 13  
Rough-in Reference ____________________________________________________________________ 14  
Component Identification ________________________________________________________________ 15  
Base Installation _______________________________________________________________________ 16-18  
Tower and Glass Panels Installation ________________________________________________________ 19-22  
2 & 3 WALL  
Operation ___________________________________________________________________________ 23  
Maintenance __________________________________________________________________________ 24  
Authorized Service _____________________________________________________________________ 24  
Tower Fixture Repair Parts _______________________________________________________________ 25  
Tower Plumbing Repair Parts _____________________________________________________________ 26  
2 Wall Unit Repair Parts _________________________________________________________________ 27  
3 Wall Unit Repair Parts _________________________________________________________________ 28  
Warranty _____________________________________________________________________________ 29-30  
Save These Instructions for Future Use.  
Owner's Record  
Date Purchased ____________________________________________________________  
Purchased From ____________________________________________________________  
Installed By ________________________________________________________________  
Serial Number _____________________________________________________________  
Model ____________________________________________________________________  
1
Download from Www.Somanuals.com. All Manuals Search And Download.  
2 WALL SPECIFICATIONS  
Important: Read complete instructions before beginning installation.  
Each unit arrives ready for installation, equipped with base, glass and associated hardware.  
Remove the unit from the carton. Retain the shipping carton until satisfactory inspection of the product has been  
made.  
Immediately upon receipt, inspect the base and other components before installing. Check all carton inserts for  
partsandhardware. Shouldinspectionrevealanydamageordefectinanycomponent, donotinstalltheunit. Damage  
or defect to any component claimed after the unit is installed is excluded from the warranty. Jacuzzi Whirlpool Bath's  
responsibility for shipping damage ceases upon delivery of the products in good order to the carrier. Refer any claims  
for damage to the carrier. For definitions of warranty coverage and limitations, refer to the published warranty  
information packed with the product.  
Jacuzzi Whirlpool Bath is not responsible for any defect that could have been discovered, repaired, or avoided by  
following this inspection.  
L
BASE SPECIFICATIONS  
45° ELBOW  
2 PROVIDED  
(LOOSE)  
1-1/2" TILE FLANGE  
DIMENSIONS  
60"  
42-5/16" ( 1075 mm) W  
4" ( 102 mm) H  
(1219 mm) L  
1/2" RIGID  
COPPER PIPE  
UNDER BASE  
PRODUCT WEIGHT (Base + Enclosure )  
196 lb  
(89 kg)  
W
TOTAL WEIGHT/  
FLOOR LOADING  
396 lb  
(180 kg)/  
23 lb/sq. ft.  
(112 kg/sq. m)  
TOP VIEW  
NOTE: MINIMUM WATER PRESSURE  
FOR THE SYSTEM IS 40 PSI.  
1-1/2" TILE FLANGE  
H
FRONT VIEW  
2
Download from Www.Somanuals.com. All Manuals Search And Download.  
2 WALL ROUGH-IN REFERENCE  
84"  
FRONT VIEW  
60"  
33-3/4"  
1-1/2" TILE FLANGE  
23"  
21-1/2"  
1/2" RIGID  
COPPER PIPE  
UNDER BASE  
27-15/16"  
42-5/16"  
COLD SUPPLY  
HOT SUPPLY  
MINIMUM WATER PRESSURE  
FOR THE SYSTEM IS 40PSI  
TOP VIEW  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
2 WALL COMPONENT IDENTIFICATION  
TOWER WITH PLUMBING,  
FIXTURES, MAGNETIC  
GASKET, BOTTOM PLATE  
AND TOP COVER  
HEX WRENCH (1)  
(PROVIDED)  
CURVED  
GLASS  
STRAIGHT  
GLASS  
(PREASSEMBLED)  
MOUNTING  
POST  
CAP (2)  
WALL  
WALL  
MOUNTING  
POST  
MOUNTING  
POST  
WALL  
TOWER  
SUPPORT  
RAIL  
MOUNT  
BRACKET (2)  
GLASS  
PANEL  
SUPPORT  
RAIL  
FRONT  
RAIL  
BRACKET  
COVER (2)  
GLAZING  
GASKET  
TAPE  
(6 PIECES)  
3 SCREWS AND  
3 WALL ANCHORS  
PER MOUNTING  
POST  
GLAZING GASKET (3)  
CURVED  
STRAIGHT  
GLASS  
GLASS  
PANEL  
GLAZING GASKET  
TOWER  
COVER  
BOTTOM  
TOWER MOUNTING  
BOLT & WASHER  
BRACKET  
CORNER  
POST  
SELF  
DRILLING  
SCREW  
BASE  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
2 WALL BASE INSTALLATION  
INSTALLATION INSTRUCTIONS  
PRELIMINARY ROUGH-IN  
Thefloorstructurebeneaththeunitmustbeableto  
support a total weight of the unit and bather. Refer  
to the table under total weight.  
STEP 2  
Remove the stainless steel strainer from the drain  
assembly. Disassemble the locknut and two gaskets  
from the back of the drain assembly. Apply a 1/4" bead  
ofcaulking(silicone)tothedrainholeandinsertthedrain  
assembly. Replace the rubber washer, fiber washer,  
and lock nut in that order. Hand tighten the locknut.  
Remove excess sealant from finished side.  
Apply a lubricant (common household liquid soap  
works well) to the inside of the rubber seal of the drain  
assembly.  
STEP 1  
Provide an opening in the subfloor no less than 5" x 5"  
square. This opening should be located on the center  
lines of the shower base drain hole (See Product Chart).  
The opening is to accommodate a 2" waste pipe. The  
waste pipe should be 1/4" to 1/2" above the surface of  
the subfloor.  
STRAINER  
APPLY LUBRICANT  
SILICONE  
SEALANT  
DRAIN  
ASSEMBLY  
90°  
SHOWER BASE  
90°  
90°  
RUBBER WASHER  
5"x5" OPENING  
(MIN. AS POSSIBLE)  
2" WASTE PIPE  
NUT  
FIBER WASHER  
As shown in top view, 1/2" copper pipes are provided  
toconnecttothewatersupply. Alsoprovidedare2loose  
45° elbows as shown for installation in Detail 1.  
STEP 3  
If the subfloor is level, no other preparation is neces-  
sary. You can proceed to install the shower base. If the  
subfloor is not level, level shower base by spreading  
floor leveling compound, mortar, plaster or minimal  
expansion structural foam with a minimum density of 5  
lbs./cubic feet EVENLY over ENTIRE area where base  
will be installed. The compound used MUST make  
contact with the entire bottom surface of the base. Both  
sides of a joint or splice of subfloor should be level to  
each other. Level and support waste pipe cutout area  
greater than 5" x 5". The base is NOT to be supported  
by the tile flange.  
CAUTION: A nonflammable protective barrier must  
be placed between soldering work and base unit to  
prevent damage to the base.  
When connecting the supply lines, the toe plate can be  
notched to accommodate the pipes.  
Thepipeunderthebasecanbecuttolength. Todoso,  
removethepipeclampsunderthebase, cutthepipeand  
reinstall pipes.  
STUD  
WALL  
NOT PROVIDED  
45° ELBOW  
PROVIDED (2)  
DEATAIL 1  
SPREAD MORTAR OR LEVELING COMPOUND ETC.  
EVENLY OVER ENTIRE AREA  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
2 WALL BASE INSTALLATION  
STEP 4  
STEP 5  
With the drain fitting passing over the center of the  
drainpipe, lower the shower base carefully into place,  
push down firmly until the base is in place. You must  
check the level of the base in two directions. Do not lift  
a corner to level the base. This will cause a loss of  
contact with the mortar. Attach the shower base flange  
to the stud wall and blocking with self-drilling screws  
(included). Use a minimum of 3 screws per flange  
section.  
With a large screwdriver and the tool included with the  
drain, tighten the inside compression nut to seal the  
drain pipe connection. After drain is fully installed, test  
for proper drainage. If the shower base does not drain  
properly, rectify this condition before proceeding with  
theinstallation. JacuzziWhirlpoolBathisnotrespon-  
sible for removal and/ or reinstallation costs.  
NOTE: Watertight installation of the drain is the  
installer’s responsibility. Drain leakage is excluded  
from the Jacuzzi Whirlpool Bath warranty.  
Replace the strainer and tape over the drain hole to  
prevent finishing material from entering drain.  
TIGHTEN SEALING NUT  
TOOL  
(INCLUDED)  
POSITION BASE OVER CENTER OF  
DRAIN PIPE AND SET INTO PLACE  
NOTE: If there is any gap between base flange and  
stud or blocking, shims MUST be used to prevent  
distortion or cracking of the flange.  
TILE  
FLANGE  
SHIM  
TILE  
FLANGE  
GAP  
USE  
SCREWS  
(PROVIDED)  
USE  
SCREWS  
(PROVIDED)  
STUD  
STUD  
INCORRECT  
CORRECT  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
2 WALL BASE INSTALLATION  
STEP 6  
STEP 8  
Place cement board or equivalent on top of shower  
base flange and secure to studwall.  
Filling the area marked DO NOT FILL will prevent  
moisture from draining back into the base through the  
weep holes. This moisture is due to leakage through the  
tile grout. Sealing the tile grout will prevent this leakage.  
CEMENT BOARD  
TILE  
CEMENT  
BOARD  
GROUT  
STUD  
STUD  
SILICONE  
SEALANT  
SHIM IF NECESSARY  
DO NOT FILL  
STEP 7  
Applytile(orotherfinishingmaterial)leavinga1/8"gap  
between the finishing material and the shower base  
flange lip. Seal this gap with silicone sealant. Leave a  
minimum 1/4" gap at the back and front corners of the  
shower base to allow drainage from leakage through  
unsealed tiled grout.  
1-1/8" MAXIMUM  
NO MINIMUM  
CLEAN-UP AFTER INSTALLATION  
To avoid dulling and scratching the acrylic surface of  
the base, never use abrasive cleaners. A mild liquid  
detergent and warm water clean soiled surfaces.  
Remove spilled plaster with a wood or plastic edge.  
Metal tools scratch the surface. Spots left by plaster or  
grout can be removed if lightly rubbed with detergent on  
a damp cloth or sponge.  
TILE  
CEMENT  
BOARD  
1/4" MINIMUM  
GAP  
Paint, tar, or other difficult stains can be removed with  
paint thinner, turpentine, or isopropyl alcohol (rubbing  
alcohol).  
TILE  
ADHESIVE  
Minor scratches which do not penetrate the color  
finish can be removed by lightly sanding with 600-grit  
wet/dry sandpaper. You can restore the glossy finish to  
the acrylic surface of the base with a special compound,  
Meguiar’s #10 Mirror Glaze. If not available, use auto-  
motive rubbing compound followed by an application of  
automotive paste wax.  
STUD  
SILICONE  
SEALANT  
1/8" GAP  
Major scratches and gouges which penetrate the  
acrylic surface require refinishing. Ask your Jacuzzi  
Whirlpool Bath dealer for special instructions.  
SILICONE  
SEALANT  
1/4" MINIMUM GAP  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
2 WALL: TOWER, FIXED WALL AND CURVED GLASS INSTALLATION  
STEP 3A  
STEP 1  
Slidestraightglasspanelallthewayintowallpost. Mark  
position of glass post. Remove panel.  
Positionthewallpostssotheedgeofthepostissetback  
3/4" (19 mm) in from the edge of the base  
3/4"  
(19 mm)  
FINISH WALL  
EDGE OF BASE  
STEP 2  
Level both wall posts in their proper position and mark  
where screw holes are to be drilled. Drill 3/16" holes and  
securewithwallanchorsandscrewsprovided. Cuta12"  
strip of tape (provided) and apply firmly over screw  
heads.  
MARK POSITION  
STEP 3B  
Apply a bead of silicone sealant on underside of bottom  
bracket corner post and place bracket where marked.  
Drill pilot holes (#8 screw) and secure bracket to base.  
Reinsertpanelintowallpostandpositionglasspostover  
bracket.  
TAPE  
6 PLACES)  
APPLY BEAD OF  
SILICONE SEALANT  
ON UNDERSIDE OF  
BOTTOM BRACKET  
CORNER POST  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
2 WALL: TOWER, FIXED WALL AND CURVED GLASS INSTALLATION  
STEP 4  
STEP 6  
Slide the glass panel into the wall post. Make sure that  
the corner notch is positioned toward the base of the  
tower.  
Insert tower support rail into glass panel rail but do not  
tighten at this time.  
GLASS PANEL  
SUPPORT RAIL  
TOWER SUPPORT RAIL  
STEP 7  
Insertsupportrailsintobracketsintopmouldingoftower  
but do not tighten at this time. Front and tower support  
rails may have to be cut if they are too long.  
TOWER SUPPORT RAIL  
FRONT RAIL  
NOTCH  
GLASS PANEL  
SUPPORT RAIL  
STEP 5  
Place the tower onto base. Ensure the curved glass  
locates into the glazing channel. Install bolt but do not  
tighten.  
BOLT (5/16")  
WASHER  
STEP 8  
Slide mounting bracket covers and mounting brackets  
onto front rail and tower support rail.  
GLAZING  
CHANNEL  
MOUNTING  
BRACKET  
COVER  
RAIL  
RAIL WALL  
MOUNTING BRACKET  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
2 WALL: TOWER, FIXED WALL AND CURVED GLASS INSTALLATION  
STEP 9  
STEP 11  
Place the front rail and tower support rail against the  
walls. Check level and mark the position for the rail  
mounting bracket. The screw position will be above the  
rail. Drill the wall with a 3/16" bit and secure bracket with  
screws and wall anchors provided.  
Secure the rails.  
ATTACH RAIL  
BRACKET TO WALL  
SECURE RAIL TO  
BRACKET (TURN CW  
TO TIGHTEN)  
STEP 12  
MOVE COVER CAP  
OVER BRACKET  
Tighten the tower base bolt. Two shut-off valves are  
provided. To hook up supply lines, unscrew valves from  
braided line. Using thread sealant, screw valve to stub  
outs at bottom of tower. Then reconnect braided line  
using provided gasket. Do not twist or kink supply lines  
when connecting.  
STEP 10  
Adjust the rails until tower is vertical in 2 planes.  
SHUT OFF  
VALVES  
(PROVIDED)  
COLD  
HOT  
BOLT  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2 WALL: TOWER, FIXED WALL AND CURVED GLASS INSTALLATION  
STEP 14  
STEP 13A  
Install cover cap on fixed glass wall post.  
Insert fixed glass support rail into panel post and tighten  
set screw.  
COVER CAP  
STEP 13B  
Drill a 1/8" pilot hole into tower support rail using the hole  
in the glass panel support rail. Screw M3.5X9.5 mm  
screw into hole.  
STEP 15  
Install glazing gasket on curved glass wall post on the  
outside. Note orientation of gasket. Soapy water may  
help to insert the glazing gasket. On the inside of  
enclosure, apply sealant the entire length of glass and  
wall post as well as the entire length of glass and tower.  
DRILL 1/8" PILOT HOLE AND  
SCREW M3.5X9.5 mm SCREW  
INTO HOLE  
GLASS PANEL  
SUPPORT RAIL  
GLASS  
INSIDE OF  
ENCLOSURE  
WALL POST  
APPLY SEALANT  
GLAZING GASKET  
GLAZING  
GASKET  
TOWER TOP PLATE  
APPLY  
SEALANT  
INSIDE OF  
ENCLOSURE  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2 WALL: TOWER, FIXED WALL AND CURVED GLASS INSTALLATION  
STEP 16  
STEP 18  
Turn on water supply and check for leaks. Correct any  
leaks before installing tower cover.  
Seal all around the base of tower with silicone sealant.  
Alsosealtheinsideofbothwallposts, glasspostandthe  
bottom of both glass panels on the inside only.  
STEP 17  
Install tower cover as shown. Insert cover at top first.  
APPLY SEALANT  
ALONG BASE  
AND SIDE OF  
WALL POST  
TOWER TOP PLATE  
APPLY SEALANT  
ALONG BASE  
APPLY SEALANT  
OF GLASS  
ALONG BASE  
OF GLASS  
TOWER COVER  
INSERT THIS SIDE FIRST  
TOWER COVER  
APPLY SEALANT  
APPLY SEALANT  
ALL AROUND  
TOWER BASE  
APPLY SEALANT  
ALONG BASE  
AND SIDE OF  
WALL POST  
AROUND  
GLASS POST  
(RAILS NOT SHOWN)  
TOP VIEW  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3 WALL SPECIFICATIONS  
Important: Read complete instructions before beginning installation.  
Each unit arrives ready for installation, equipped with base, glass and associated hardware.  
Remove the unit from the carton. Retain the shipping carton until satisfactory inspection of the product has been  
made.  
Immediately upon receipt, inspect the base and other components before installing. Check all carton inserts for  
partsandhardware. Shouldinspectionrevealanydamageordefectinanycomponent, donotinstalltheunit. Damage  
or defect to any component claimed after the unit is installed is excluded from the warranty. Jacuzzi Whirlpool Bath's  
responsibility for shipping damage ceases upon delivery of the products in good order to the carrier. Refer any claims  
for damage to the carrier. For definitions of warranty coverage and limitations, refer to the published warranty  
information packed with the product.  
Jacuzzi Whirlpool Bath is not responsible for any defect that could have been discovered, repaired, or avoided by  
following this inspection.  
L
BASE SPECIFICATIONS  
45° ELBOW  
2 PROVIDED  
(LOOSE)  
1-1/2" TILE FLANGE  
DIMENSIONS  
60"  
(1219 mm) L  
42-5/16" ( 1075 mm) W  
4"  
( 102 mm) H  
1/2" RIGID  
COPPER PIPE  
UNDER BASE  
PRODUCT WEIGHT (Base + Enclosure )  
140 lb  
(64 kg)  
W
TOTAL WEIGHT/  
FLOOR LOADING  
340 lb  
(155 kg)/  
23 lb/sq. ft.  
(97 kg/sq. m)  
TOP VIEW  
NOTE: MINIMUM WATER PRESSURE  
FOR THE SYSTEM IS 40 PSI.  
1-1/2" TILE FLANGE  
H
FRONT VIEW  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3 WALL ROUGH-IN REFERENCE  
84"  
FRONT VIEW  
60"  
33-3/4"  
1-1/2" TILE FLANGE  
23"  
21-1/2"  
1/2" RIGID  
COPPER PIPE  
UNDER BASE  
27-15/16"  
42-5/16"  
COLD SUPPLY  
HOT SUPPLY  
MINIMUM WATER PRESSURE  
FOR THE SYSTEM IS 40PSI  
TOP VIEW  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3 WALL COMPONENT IDENTIFICATION  
TOWER WITH PLUMBING,  
FIXTURES, MAGNETIC  
CURVED  
GLASS  
GASKET, BOTTOM PLATE  
AND TOP COVER  
HEX WRENCH (1)  
(PROVIDED)  
WALL  
(PREASSEMBLED)  
MOUNTING  
POST  
CAP  
MOUNTING  
POST  
WALL  
TOWER  
MOUNT  
SUPPORT  
RAIL  
BRACKET (2)  
FRONT  
RAIL  
BRACKET  
COVER (2)  
TAPE  
(3 PLACES)  
3 SCREWS AND  
3 WALL ANCHORS  
GLAZING  
GASKET  
CURVED  
GLASS  
GLAZING GASKET (2)  
TOWER COVER  
TOWER MOUNTING  
BOLT & WASHER  
SELF  
DRILLING  
SCREW  
BASE  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3 WALL BASE INSTALLATION  
PRELIMINARY ROUGH-IN  
INSTALLATION INSTRUCTIONS  
Thefloorstructurebeneaththeunitmustbeableto  
support a total weight of the unit and bather. Refer  
to the table under total weight.  
STEP 2  
Remove the stainless steel strainer from the drain  
assembly. Disassemble the locknut and two gaskets  
from the back of the drain assembly. Apply a 1/4" bead  
ofcaulking(silicone)tothedrainholeandinsertthedrain  
assembly. Replace the rubber washer, fiber washer,  
and lock nut in that order. Hand tighten the locknut.  
Remove excess sealant from finished side.  
Apply a lubricant (common household liquid soap  
works well) to the inside of the rubber seal of the drain  
assembly.  
STEP 1  
Provide an opening in the subfloor no less than 5" x 5"  
square. This opening should be located on the center  
lines of the shower base drain hole (See Product Chart).  
The opening is to accommodate a 2" waste pipe. The  
waste pipe should be 1/4" to 1/2" above the surface of  
the subfloor.  
STRAINER  
APPLY LUBRICANT  
SILICONE  
SEALANT  
DRAIN  
ASSEMBLY  
SHOWER BASE  
90°  
90°  
RUBBER WASHER  
2" WASTE PIPE  
5"x5" OPENING (MIN. AS POSSIBLE)  
NUT  
FIBER WASHER  
As shown in top view, 1/2" copper pipes are provided  
toconnecttothewatersupply. Alsoprovidedare2loose  
45° elbows as shown for installation in Detail 1.  
STEP 3  
If the subfloor is level, no other preparation is neces-  
sary. You can proceed to install the shower base. If the  
subfloor is not level, level shower base by spreading  
floor leveling compound, mortar, plaster or minimal  
expansion structural foam with a minimum density of 5  
lbs./cubic feet EVENLY over ENTIRE area where base  
will be installed. The compound used MUST make  
contact with the entire bottom surface of the base. Both  
sides of a joint or splice of subfloor should be level to  
each other. Level and support waste pipe cutout area  
greater than 5" x 5". The base is NOT to be supported  
by the tile flange.  
CAUTION: A nonflammable protective barrier must  
be placed between soldering work and base unit to  
prevent damage to the base.  
When connecting the supply lines, the toe plate can be  
notched to accommodate the pipes.  
Thepipeunderthebasecanbecuttolength. Todoso,  
removethepipeclampsunderthebase, cutthepipeand  
reinstall pipes.  
STUD  
WALL  
NOT PROVIDED  
45° ELBOW  
PROVIDED (2)  
DEATAIL 1  
SPREAD MORTAR OR LEVELING COMPOUND ETC.  
EVENLY OVER ENTIRE AREA  
16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3 WALL BASE INSTALLATION  
STEP 4  
STEP 5  
With the drain fitting passing over the center of the  
drainpipe, lower the shower base carefully into place,  
push down firmly until the base is in place. You must  
check the level of the base in two directions. Do not lift  
a corner to level the base. This will cause a loss of  
contact with the mortar. Attach the shower base flange  
to the stud wall and blocking with self-drilling screws  
(included). Use a minimum of 3 screws per flange  
section.  
With a large screwdriver and the tool included with the  
drain, tighten the inside compression nut to seal the  
drain pipe connection. After drain is fully installed, test  
for proper drainage. If the shower base does not drain  
properly, rectify this condition before proceeding with  
theinstallation. JacuzziWhirlpoolBathisnotrespon-  
sible for removal and/ or reinstallation costs.  
NOTE: Watertight installation of the drain is the  
installer’s responsibility. Drain leakage is excluded  
from the Jacuzzi Whirlpool Bath warranty.  
Replace the strainer and tape over the drain hole to  
prevent finishing material from entering drain.  
WHEN SCREWING FLANGE TO STUD  
WALL START WITH THIS SIDE  
TIGHTEN SEALING NUT  
TOOL  
(INCLUDED)  
POSITION BASE OVER CENTER OF  
DRAIN PIPE AND SET INTO PLACE  
NOTE: If there is any gap between base flange and  
stud or blocking, shims MUST be used to prevent  
distortion or cracking of the flange.  
TILE  
FLANGE  
SHIM  
TILE  
FLANGE  
GAP  
USE  
SCREWS  
(PROVIDED)  
USE  
SCREWS  
(PROVIDED)  
STUD  
STUD  
INCORRECT  
CORRECT  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3 WALL BASE INSTALLATION  
STEP 6  
STEP 7  
With the drain fitting passing over the center of the  
drainpipe, lower the shower base carefully into place,  
push down firmly until the base is in place. You must  
check the level of the base in two directions. Do not lift  
a corner to level the base. This will cause a loss of  
contact with the mortar. Attach the shower base flange  
to the stud wall and blocking with self-drilling screws  
(included). Use a minimum of 3 screws per flange  
section.  
With a large screwdriver and the tool included with the  
drain, tighten the inside compression nut to seal the  
drain pipe connection. After drain is fully installed, test  
for proper drainage. If the shower base does not drain  
properly, rectify this condition before proceeding with  
theinstallation. JacuzziWhirlpoolBathisnotrespon-  
sible for removal and/ or reinstallation costs.  
NOTE: Watertight installation of the drain is the  
installer’s responsibility. Drain leakage is excluded  
from the Jacuzzi Whirlpool Bath warranty.  
Replace the strainer and tape over the drain hole to  
prevent finishing material from entering drain.  
CEMENT BOARD  
TILE  
CEMENT  
BOARD  
GROUT  
STUD  
STUD  
SILICONE  
SEALANT  
SHIM IF NECESSARY  
DO NOT FILL  
NOTE: If there is any gap between base flange and  
stud or blocking, shims MUST be used to prevent  
distortion or cracking of the flange.  
1-1/8" MAXIMUM  
NO MINIMUM  
CLEAN-UP AFTER INSTALLATION  
SILICONE  
SEALANT  
To avoid dulling and scratching the acrylic surface of  
the base, never use abrasive cleaners. A mild liquid  
detergent and warm water clean soiled surfaces.  
Remove spilled plaster with a wood or plastic edge.  
Metal tools scratch the surface. Spots left by plaster or  
grout can be removed if lightly rubbed with detergent on  
a damp cloth or sponge.  
1/4" MINIMUM GAP  
Paint, tar, or other difficult stains can be removed with  
paint thinner, turpentine, or isopropyl alcohol (rubbing  
alcohol).  
Minor scratches which do not penetrate the color  
finish can be removed by lightly sanding with 600-grit  
wet/dry sandpaper. You can restore the glossy finish to  
the acrylic surface of the base with a special compound,  
Meguiar’s #10 Mirror Glaze. If not available, use auto-  
motive rubbing compound followed by an application of  
automotive paste wax.  
TILE  
CEMENT  
BOARD  
1/4" MINIMUM  
GAP  
Major scratches and gouges which penetrate the  
acrylic surface require refinishing. Ask your Jacuzzi  
Whirlpool Bath dealer for special instructions.  
TILE  
ADHESIVE  
STUD  
SILICONE  
SEALANT  
1/8" GAP  
18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3 WALL: TOWER AND CURVED GLASS INSTALLATION  
STEP 3  
STEP 1  
Slide the glass panel into the wall post. Make sure that  
the corner notch is positioned toward the base of the  
tower.  
Position the wall post so the edge of the post is set back  
3/4" (19 mm) in from the finish wall.  
FINISH WALL  
3/4"  
(19 mm)  
STEP 2  
Level the post in its proper position and mark where  
screwholesaretobedrilled. Drill3/16"holesandsecure  
with wall anchors and screws provided. Cut a 12" strip  
of tape (provided) and apply firmly over screw heads.  
NOTCH  
STEP 4  
Place the tower onto base. Ensure the curved glass  
locates into the glazing channel. Install bolt but do not  
tighten.  
TAPE  
3 PLACES)  
BOLT (5/16")  
WASHER  
GLAZING  
CHANNEL  
19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3 WALL: TOWER AND CURVED GLASS INSTALLATION  
STEP 7  
STEP 5  
Place the front rail and tower support rail against the  
walls. Check level and mark the position for the rail  
mounting bracket. The screw position will be above the  
rail. Drill the wall with a 3/16" bit and secure bracket with  
screws and wall anchors provided.  
Insertsupportrailsintobracketsintopmouldingoftower  
but do not tighten at this time.  
TOWER SUPPORT RAIL  
FRONT RAIL  
ATTACH RAIL  
BRACKET TO WALL  
SECURE RAIL TO  
BRACKET (TURN CW  
TO TIGHTEN)  
STEP 6  
Slide mounting bracket covers and mounting brackets  
onto front rail and tower support rail.  
MOVE COVER CAP  
OVER BRACKET  
MOUNTING  
BRACKET  
COVER  
RAIL  
STEP 8  
Adjust the rails until tower is vertical in 2 planes.  
RAIL WALL  
MOUNTING BRACKET  
20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3 WALL: TOWER AND CURVED GLASS INSTALLATION  
STEP 9  
STEP 11  
Secure the rails.  
Install cover cap on wall post.  
COVER CAP  
STEP 10  
STEP 12  
Tighten the tower base bolt. Two shut-off valves are  
provided. To hook up supply lines, unscrew valves from  
braided line. Using thread sealant, screw valve to stub  
outs at bottom of tower. Then reconnect braided line  
using provided gasket. Do not twist or kink supply lines  
when connecting.  
Install glazing gasket on curved glass wall post on the  
outside. Note orientation of gasket. Soapy water may  
help to insert the glazing gasket. On the inside of  
enclosure, apply sealant the entire length of glass and  
wall post as well as the entire length of glass and tower.  
SHUT OFF  
VALVES  
(PROVIDED)  
GLASS  
COLD  
INSIDE OF  
ENCLOSURE  
WALL POST  
HOT  
BOLT  
APPLY SEALANT  
GLAZING GASKET  
GLAZING  
GASKET  
TOWER TOP PLATE  
APPLY  
SEALANT  
INSIDE OF  
ENCLOSURE  
21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3 WALL: TOWER AND CURVED GLASS INSTALLATION  
STEP 13  
STEP 15  
Turn on water supply and check for leaks. Correct any  
leaks before installing tower cover.  
Seal all around the base of tower with silicone sealant.  
Also seal the inside of both wall posts, bottom of both  
glass panels on the inside only.  
STEP 14  
Install tower cover as shown. Insert cover at top first.  
APPLY SEALANT  
ALONG BASE  
OF GLASS  
TOWER TOP PLATE  
TOWER COVER  
APPLY SEALANT  
ALL AROUND  
TOWER BASE  
APPLY SEALANT  
ALONG BASE  
AND SIDE OF  
WALL POST  
INSERT THIS SIDE FIRST  
TOWER COVER  
(RAILS NOT SHOWN)  
TOP VIEW  
22  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2 & 3 WALL OPERATION  
Shower Head  
There are four selectable positions: Jet, normal pulsating and  
aerated flow.  
Body Sprays (2 Upper & 2 Lower)  
To adjust the flow and intensity, turn as shown. The spray can also  
be turned to change the direction of the spray.  
LESS FLOW AND INTENSITY  
MORE FLOW AND INTENSITY  
Diverter Control  
To turn On water, turn the inner knob clockwise and adjust for more  
or less flow.  
The outer knob will divert the water to body sprays, shower head  
(shown in this position) and foot temperature tester. If the knob is  
pointing anywhere between main functions, the amount of water  
will be proportional to where the knob is pointing. If the knob is  
pointing to the white line between positions, the water will be  
diverted equally to both functions on either side of the white line.  
STOP RELEASE  
SHOWER  
HEAD  
BODY  
SPRAY  
FOOT  
TEMPERATURE  
TESTER  
INNER  
KNOB  
OUTER  
KNOB  
Temperature Valve  
The temperature of the mixed water is adjusted by means of the  
graduated handle. This handle has a safety stop set at 100°F  
(38°C). To increase the temperature, press the red button to release  
the stop and keep turning the handle.  
Foot Temperature Testor  
23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2 & 3 WALL MAINTENANCE  
To remove any lime scale from the shower head and body sprays , rub with your finger the outer ring of nozzles on  
the shower head and all nozzles on the body spray.  
To clean the foot temperature tester, unscrew the nozzle and back flush the wire mesh filter. Do not use metal tools  
(such as scissors or screwdrivers, etc.) to clean the body sprays, shower head or foot temperature tester.  
To cleanthe base, simply use a mild, nonabrasive liquid detergent solution. You can protect and restore the gloss to  
a dulled acrylic surface by applying Meguiar's #10 Mirror Glaze, a product specifically designed for use on acrylic  
finishes. If Meguiar's is not available, an acrylic polish of equal quality or automotive paste wax is acceptable.  
The glass can be cleaned with any glass-cleaning product available on the market.  
Do not use abrasives, alcohol, acetone, ammonia or other solvents on any tower component.  
The thermostatic valve has 2 screen filters that should be cleaned periodically. To remove the filters turn off hot and  
cold supplies. Remove tower cover. Disconnect the supply hoses from the valve and remove filter from the hose.  
Clean any debris. Reinstallation is the reverse of removal. Turn on hot and cold supply and check for leaks.  
Authorized Service  
If you need a referral for a service company near you, or need assistance with operation or maintenance related  
questions, please call our Service Support Department at 1-800-288-4002. For service agent listing, visit our web site  
Mechanical Service Agents. Depending on the problem, click on “Electrical/Mechanical Repairs” or “Finish, Surface  
or Shell-Related Problems”.  
PRODUCT SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE.  
USE INSTALLATION INSTRUCTIONS SUPPLIED WITH PRODUCT.  
Jacuzzi Whirlpool Bath has obtained applicable code (standards) listings generally available on a national basis for products of  
this type. It is the responsibility of the installer/owner to determine specific local code compliance prior to installation of the product.  
Jacuzzi Whirlpool Bath makes no representation or warranty regarding, and will not be responsible for any code compliance.  
Jacuzzi Whirlpool Bath  
P.O. Box 702168, Dallas, TX 75370-2168  
Service Support: Call (800) 288-4002  
© 2002 Jacuzzi Whirlpool Bath U223000 8/13/04  
Printed on Recycled Paper  
Printed in U.S.A.  
24  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TOWER FIXTURES REPAIR PARTS  
1 (5X)  
2 (5X)  
3 (5X)  
TOWER ASSEMBLY  
4
9 (5X)  
6
10  
5
11 (4X)  
7 (Part of U547000)  
8
12  
13  
14  
15  
16  
17  
18  
PART OF D709827  
WASHER (PART OF D709827)  
19  
1. C546000 Lock Nut, 1/2" NPT WP (5X)  
2. G559000 Ring Compression SS (5X)  
3. G560000 Washer Rubber (5X)  
4. U546000 (Part of U547000) Nut Transfer Valve, Chrome  
5. U566000 Gasket, 1.41 ID X .063 Thick  
6. U547000 Valve, Mixer/Transfer Assembly  
7. U550827 (Part of U547000) 567000Nut, Mixer Valve, Chrome  
8. U567000 Gasket, 1.9 ID X .063 Thick  
9. G432000 Nipple,1/2" Close  
10. U217827 Shower Head, Chrome  
11. U215827 Jet, Wall Body, Chrome  
12. U219827 Face Plate, Transfer Valve, Chrome  
13. U546827 Nut Transfer Valve, Chrome  
14. U545827 Collar, Transfer Valve, Chrome  
15. U544000 O-Ring, Transfer Valve  
16. U543827 Knob, Flow Control, Chrome  
17. U549827 Collar, Mixer Valve, Chrome  
18. U548827 Knob, Mixer Valve Chrome  
19. D709827 Fill Spout Assembly, Stubby, Chrome  
25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TOWER PLUMBING REPAIR PARTS  
1. A944000 (9X) Spring Clamp, .625 OD Hose  
2. U405000 L=31.0" Tubing, PVC Reinforced, 10mm Barb  
3. U405000 L=5.5" Tubing, PVC Reinforced, 10mm Barb  
4. A945000 (7X) Spring Clip, .75 OD Hose  
5. U400000 FTG, Straight, 1/2" FTS X 10mm Barb  
6. U403000 (2X) Cap, 1/2" FST  
1 (9X)  
See Note 1  
2
7. U711000 (2X) Strainer Washer, 1/2" Dia.  
8. U405000 L=31.0" Tubing, PVC Reinforced, 10mm Barb  
9. U540000 (2X) 1/2" Flexhose 38", Female Swivel Heads  
10. GASKET (2X) Gaskets Supplied with Hose  
11. U827000 (2X) Ball Valve, .5 FTP X .5 MPT L  
12. U421000 (11X) Washer, FTG .7 OD  
12 (11X)  
13 (7X)  
13. U401000 (7X) FTG, Ell, 1/2" FST X 10mm Barb  
14. U405000 L=4.5" Tubing, PVC Reinforced, 10mm Barb  
15. U404000 (2X) FTG, Y, 10mm X 10mm X 10mm Barb  
16. U405000 L=2.5" Tubing, PVC Reinforced, 10mm Barb  
17. U402000 FTG, Tee, 1/2" FST X 10mm Barb  
18. U405000 L=10.0" Tubing, PVC Reinforced, 10mm Barb  
19. U405000 L=4.5" Tubing, PVC Reinforced, 10mm Barb  
20. U405000 L=5.5" Tubing, PVC Reinforced, 10mm Barb  
3
14  
4 (7X)  
See Note 2  
15 (2X)  
16  
17  
5
Note 1: For Clamping U405000 to U401000 or U402000.  
Note 2: For Clmping U405000 to U400000 or U404000.  
18  
6
7
8
19  
9 (2X)  
20  
10 (2X)  
11  
26  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2 WALL UNIT REPAIR PARTS  
5 (2X) 6 (2X)  
7 (6X)  
4
1
3
2
8
11  
12  
9
10  
14 (6X)  
13 (6X)  
17  
19 (Used with Tower with Timber Finish Only)  
18  
21  
15  
1. U134827 Rail Back Walk-in  
2. U133827 Rail 2 Wall Walk-in  
3. U245827 Rail Assembly Walk-in  
4. U149000 Bracket, Mounting Rail  
5. U119827 Wall Post, Panel  
16  
6. U138827 Cap, Wall Post  
7. J686000 Tape High Bond, 2 Sided  
8. U159000 Gasket,Vinyl, Glass Panel  
9. U479XXX Glass Panel Assembly, Walk-in  
10. U124XXX Tower Cover  
22  
20  
11. U257XXX Final Shell, Tower Walk-in  
U126XXX Tower Body Walk-in  
U136XXX Cap, Top, Tower  
U137XXX Cap, Bottom, Tower  
U149000 Bracket, Mounting Rail  
For colors for U174XXX Shower Base  
substitute XXX for:  
Standard  
For finishes for U124XXX Tower  
Cover and U257XXX Tower Final  
Shell substitute XXX for:  
801 Satin  
U354000 Screw, Self Tap, #8-1.25" L  
U355000 Screw, Self Tap, #8-2.0" L  
12. U113000 Glass Panel, Front, Wlak-in  
13. U354000 Screw Self Tap #8 X 1.25" L  
14. U703000 Anchor, #6-8-10  
15. 5374832 Screw, Sheet Metal PHP, #6 X .88" L  
16. U196000 Bracket Corner Post, Bottom  
17. 3952832 Bolt Hex FL Thrd 5/16  
18. 3983832 Washer 5/16 Flat Type A Plnwdser  
19. U247000 Gasket,Vinyl, Glass Panel  
20. U174XXX Shower base Walk-in 2 Wall  
21. U220000 Screw Self Drilling, #8 X 1.63" L  
22 9959000 Drain, Non-Caulk  
959 White  
958 Almond  
827 Chrome  
969 Oyster  
938 Timber  
959 White  
945 Silver  
High Fashion  
917 Black  
949 Rose  
951 Shell  
978 Forest Green  
984 Shy Blue  
999 Sand  
27  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3 WALL UNIT REPAIR PARTS  
5
1
3 (2X)  
4
2
10  
11  
7
8 (2X)  
9
1. U134827 Rail Back Walk-in 3 Wall  
6
2. U245827 Rail Assembly Walk-in 3 Wall  
3. U149000 Bracket, Mounting Rail  
4. U119827 Wall Post, Panel  
5. U138827 Cap, Wall Post  
6. U124XXX Tower Cover  
13  
7. U257XXX Final Shell, Tower, Walk-in 3-Wall  
U126XXX Tower Body Walk-in  
12  
U136XXX Cap, Top Tower  
U137XXX Cap, Bottom, Tower  
U149000 Bracket, Mounting Rail  
U354000 Screw, Self Tap,#8-1.25" L  
U355000 Screw, Self Tap,#8-2.0" L  
8. U247000 Gasket,Vinyl, Glass Panel  
9. U113000 Glass, Panel, Front, Walk-in  
10. U159000 Gasket,Vinyl, Glass Panel  
11. J686000 Tape, High Bond, 2-Sided  
12. U354000 Screw Self Tap, #8-1.25" L  
13. U703000 Anchor, #6-8-10  
14. 3952832 Bolt Full Thread, 5/16  
15. 3983832 Washer, 5/16, Flat, Type 2 Plnwser  
16. U171XXX Shower base, Walk-in, 3-Wall  
17. U220000 Screw Self Drilling, #8 X 1.63" L  
18. 9959000 Drain, Non-Caulk  
For finishes for U124XXX Tower  
Cover and U257XXX Tower Final  
Shell substitute XXX for:  
801 Satin  
17 (10X)  
827 Chrome  
938 Timber  
959 White  
14  
15  
For colors for U171XXX Shower Base  
substitute XXX for:  
Standard  
959 White  
958 Almond  
969 Oyster  
945 Silver  
18  
High Fashion  
917 Black  
16  
949 Rose  
951 Shell  
978 Forest Green  
984 Shy Blue  
999 Sand  
28  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Jacuzzi Whirlpool Bath Limited Warranty  
Designer Collection Shower Product  
WARRANTY COVERAGE  
Jacuzzi Whirlpool Bath (the “Company”) offers the following express limited warranty to the original purchaser of any Jacuzzi Whirlpool Bath Designer  
Collection Bath Product (“unit”) who purchases the product for personal or single family use (“user”). The Company will repair or replace, at its option, the  
unit or its equipment in accordance with the following terms and conditions.  
TWO YEAR LIMITED WARRANTY ON BATHS  
Our limited warranty on Designer Collection Bath products is for two (2) years. Our warranty covers the unit and factory-installed components against  
defects in material or workmanship. Warranty coverage begins on the date the unit was originally purchased by the user.  
NINETY DAY (PARTS ONLY) LIMITED WARRANTY ON OPTIONS AND ACCESSORIES  
Our limited warranty on options and accessories manufactured by the Company is for ninety (90) days for parts only. Our warranty covers options and  
accessoriesmanufacturedbytheCompanyagainstdefectsofmaterialorworkmanship.Warrantycoveragebeginsonthedatetheoptionoraccessorywasoriginally  
purchased by the user.  
WARRANTY LIMITATIONS  
Our limited warranty does not cover defects, damage, or failure caused by the common carrier, installer, user, or other person, or resulting from, without  
limitation, any of the following: careless handling (lifting unit by plumbing, abrading finish, etc.); modification of any type for any reason (including modification  
to meet local codes); improper installation (including installation not in accordance with instructions and specifications provided with the unit); connections  
supplied by the installer of the equipment; improper voltage supply or unauthorized electrical modification; misuse; incorrect operation, or lack of proper routine  
maintenance; operation of the unit without specified minimum amount of water or at inappropriate water temperature; use of abrasive or improper cleaners; or  
acts of God, such as lightning, floods, earthquakes, etc.  
In addition, THE COMPANY WILL NOT BE RESPONSIBLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES or losses arising from any cause  
(e.g., water damage to carpet, ceiling, loss of use, etc.) including its own negligence; damages to, respecting, or resulting from: plated parts when pool and/or spa  
chemicals are used in the unit; optional bath equipment not manufactured by the Company but supplied by Dealer, installer or the Company; the unit's prior usage  
as an operational display; or defects that should have been discovered before installation. This limited warranty does not include: labor, transportation, or other  
costs incurred in the removal and/or reinstallation of the original unit and/or installation of a replacement unit; any costs relating to obtaining access for repair;  
orlossofusedamage,includinglossofsales,profitorbusinessadvantageofanykindunderanycircumstances.Bathunitsareexcludedfromanywarrantycoverage  
if any addition, deletion, or modification of any kind whatsoever has been made to the unit (or to any component).  
Warranty coverage is provided in the United States of America and Canada.  
EXCLUSION OF IMPLIED WARRANTIES  
IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE DISCLAIMED ALTOGETHER OR TO  
THE FULL EXTENT ALLOWED BY LAW.  
NOTICE: This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. There are no warranties applicable  
to Jacuzzi Whirlpool Bath products except as expressly stated herein or as implied by applicable state and federal laws. The Company will not be responsible for  
any statements or representations made in any form that go beyond, are broader than or are inconsistent with any authorized literature or specifications furnished  
by the Company.  
Some states do not allow limitations on how long an implied warranty lasts, or the exclusion or limitation of incidental or consequential damages, so the above  
limitations and exclusions may not apply to you.  
RETURN OF WARRANTY CARD  
The attached Warranty Registration Card MUST be filled out by the purchaser within thirty (30) days from purchase and mailed to Jacuzzi Whirlpool Bath  
in order for this warranty to become effective.  
Jacuzzi Whirlpool Bath  
P.O. Box 702168  
Dallas, TX 75370-2168  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RESPONSIBILITIES OF OTHERS  
Inspectingtheunitpriortoinstallationistheresponsibilityoftheinstallerorbuildingcontractorwhoactsonbehalfoftheuser.Theyareresponsibleforensuring  
the unit is free of defect or damage. Notices are placed on and in the unit and on the shipping carton advising the installer of this responsibility. In the event of  
a problem, the unit must not be installed. The Company is not responsible for failures or damage that could have been discovered, repaired, or avoided by proper  
inspection and testing prior to installation.  
Damage occurring in transit is the responsibility of the carrier. The user or installer MUST open the crate and inspect the unit for damage when it is delivered.  
If damage is discovered, it must be reported immediately to the seller and the carrier in writing, and an inspection requested. Failure of the carrier to respond should  
be reported to the seller and the carrier. Your freight claims should be filed promptly thereafter.  
It is the responsibility of the installer, building contractor, or user to provide access for service. The Company is not responsible for any costs relating to  
obtaining access for repair. The user shall bear such costs and, if appropriate, must seek recovery from the installer.  
Damage occurring to the unit during installation is the responsibility of the installer and/or building contractor and damage occurring thereafter is the  
responsibility of the user.  
Failure of any optional equipment is the sole responsibility of the equipment manufacturer. (Options and accessories manufactured by the Company are  
warranted for ninety (90) days from the original date of purchase for parts only.)  
The Distributor or Dealer is responsible for knowing local code requirements and notifying the installing contractor and/or user of these requirements at the  
time of purchase. The Company is not responsible for costs to modify any product to obtain any code approval, such as city, county, or state building codes in  
U.S.A. or municipal or provincial codes in Canada.  
WARRANTY SERVICE  
For the customer's benefit, the Company maintains a list of independent service personnel to perform required warranty service repairs. Such firms are not agents  
or representatives of the Company and cannot bind the Company by words or conduct.  
The Company will provide the warranty service described above when the following conditions have been met: the failure is of the nature or type covered  
by the warranty; the user has informed an Authorized Jacuzzi Whirlpool Bath Service Agent or Warranty Service Department Representative of the nature of the  
problem during the warranty period; conclusive evidence (e.g., proof of purchase or installation) is provided to the foregoing by the user proving that the failure  
occurred or was discovered within the warranty period; an authorized independent service person or Company representative has been permitted to inspect the  
unit during regular business hours within a reasonable time after the problem was reported by the user.  
Inordertoobtainwarrantyservice,consultyourlocaltelephonebookforthelocationofthenearestJacuzziWhirlpoolBathAuthorizedServiceAgent.Describe  
the problem and the Authorized Service Agent will inspect the unit and provide the required warranty service.  
If you are unable to contact a Jacuzzi Whirlpool Bath Authorized Service Agent, call or write:  
Jacuzzi Whirlpool Bath  
Warranty Service Department  
P.O. Box 702168  
Dallas, TX 75370-2168  
Call: (800) 288-4002  
To obtain warranty replacement for factory-installed components for Company supplied options and accessories manufactured and supplied by the Company,  
call or write the above. Provide a description of the problem and proof of purchase. You will be instructed how to obtain replacements and where to return, at  
your expense, the failed component(s), option(s), or accessory(ies).  
All replacement parts, equipment, and repairs shall assume the remaining warranty period of the part(s) replaced.  
The Company's warranty obligation shall be discharged upon tender of replacement or repair. The customer's refusal to accept the tender terminates the  
Company's warranty obligation.  
©2002 Jacuzzi Whirlpool Bath U223000 8/13/04  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Infinity Speaker System TSS FMK4000 User Manual
Intel Computer Hardware 281786 002 User Manual
Intelligent Motion Systems Welding System Integral Driver and Power Supply User Manual
Interfire Audio Stereo Amplifier A10002 User Manual
Jabra Cell Phone V3I User Manual
JVC Car Speaker CS ARS500 User Manual
Kenwood Car Speaker KFC PS1300P User Manual
Kenwood Marine Radio TK 5710 User Manual
KitchenAid Oven KEBS177SSS03 User Manual
Kompernass Speaker System KH 2265 User Manual