Introduction
Safety Precautions
INFORMATION FOR USA
INFORMATION
FOR USA AND CANADA
This equipment has been tested and found to comply with the
limits for a Class B digital device, pursuant to Part 15 of the FCC
Rules.
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
These limits are designed to provide reasonable protection against
harmful interference in a residential installation. This equipment
generates, uses, and can radiate radio frequency energy and, if
not installed and used in accordance with the instructions, may
cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular
installation.
If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
: TO REDUCE THE RISK OF ELECTRIC SHOCK.
DO NOT REMOVE COVER (OR BACK). NO
USER-SERVICEABLE PARTS INSIDE.REFER
SERVICING TO QUALIFIED SERVICE
PERSONNEL.
CAUTION
The lightning flash wish arrowhead symbol, within an
equilateral triangle isintended to alert the user to the
presence of uninsulated "dangerous voltage" within the
product's enclosure thatmay be of sufficient magnitude to
constitute a risk of electric shock to persons.
0
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from
0
The exclamation point within an equilateral triangle is
intended to alert theuser to the presence of important
operating and maintenance (servicing) instructions in
the literature accompanying the appliance.
that to which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
0
CAUTION
CHANGES OR MODIFICATIONS NOT APPROVED BY JVC
COULD VOID USER'S AUTHORITY TO OPERATE THE
EQUIPMENT.
WARNING:
TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT
EXPOSE THIS APPLIANCE TO RAIN OR MOISTURE.
THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES.
OPERATION IS SUBJECT TO THE FOLLOWING TWO
CONDITIONS: (1) THIS DEVICE MAY NOT CAUSE HARMFUL
INTERFERENCE, AND (2) THIS DEVICE MUST ACCEPT ANY
INTERFERENCE RECEIVED, INCLUDING INTERFERENCE
THAT MAY CAUSE UNDESIRED OPERATION.
AVERTISSEMENT:
POUR EVITER LES RISQUES D'INCENDIE OU D'ELECTROCUTION,
NE PAS EXPOSER L'APPAREIL A L'HUMIDITE OU A LA PLUIE.
INFORMATION (FOR CANADA)
RENSEIGNEMENT (POUR CANADA)
This Class B digital apparatus complies with Canadian ICES-003.
Cet apparéil numerique de la Classe B est conforme à la norme
NMB-003 du Canada.
4
5
Download from Www.Somanuals.com. All Manuals Search And Download.
Introduction
POWER SYSTEM
Connection to the mains supply
Safety Precautions (continued)
This unit operates on voltage of 220 V to 240 V AC, 50 Hz/60 Hz.
Information for Users on Disposal of Old Equipment
[European Union]
CAUTION
This symbol indicates that the electrical and electronic equipment
should not be disposed as general household waste at its end-of-
life. Instead, the product should be handed over to the applicable
collection point for the recycling of electrical and electronic
equipment for proper treatment, recovery and recycling in
accordance with your national legislation.
To prevent electric shock, do not open the cabinet.
No user serviceable parts inside. Refer servicing to qualified service
personnel.
Dear Customer,
This apparatus is in conformance with the valid European directives and
standards regarding electromagnetic compatibility and electrical safety.
By disposing of this product correctly, you will help to conserve
natural resources and will help prevent potential negative effects on
the environment and human health which could otherwise be
caused by inappropriate waste handling of this product. For more
information about collection point and recycling of this product,
please contact your local municipal office, your household waste
disposal service or the shop where you purchased the product.
Penalties may be applicable for incorrect disposal of this waste, in
accordance with national legislation.
Attention:
European representative of Victor Company of Japan Limited.is:
JVC Technology Centre Europe GmbH
P. O.Box 10 05 52
This symbol
is only valid in
the European
Union.
61145 Friedberg
Germany
(Business users)
If you wish to dispose of this product, please visit our web page
the product.
Sehr geehrter Kunde, sehr geehrte Kundin,
dieses Gerät stimmt mit den gültigen europäischen Richtlinien und
Normen bezüglich elektromagnetischer Verträglichkeit und elektrischer
Sicherheit überein.
[Other Countries outside the European Union]
If you wish to dispose of this product, please do so in accordance
with applicable national legislation or other rules in your country for
the treatment of old electrical and electronic equipment.
Die europäische Vertretung für die Victor Company of Japan, Limited ist:
JVC Technology Centre Europe GmbH
Postfach 100552
Erklärung zum Rauschen (für die Bundesrepublik Deutschland):
Maschinenlärminformations-Verordunung 3. GPSGV, 06.01.2004: Der höchste
Schalldruckpegel beträgt 70 dB(A) oder weniger gamäß EN ISO 7779
61145 Friedberg
Deutschland
ⅷ
The unit is to be powered by a DC12 V or an AC24 V power supply.
Due to design modifications, data given in this instruction book are subject
to possible change without prior notice.
ⅷ
ⅷ
The unit is to be powered by a UL Listed DC12 V or an ACD24 V power supply.
The AC24 V and 12 V DC power supply shall conform to the following: Class 2 only
(For USA), Isolated power supply only (For Europe).
ⅷ
This installation should be made by a qualified service person and should conform to
all local codes.
Wegen Entwurfsmodifikationen ist es möglich, dass die in dieser
Anleitung gegebenen Daten ohne vorherige Ankündigung geändert
werden.
6
7
Download from Www.Somanuals.com. All Manuals Search And Download.
Introduction
Thank you for purchasing this product.
Contents
(These instructions are for TK-C1530U/E and TK-C1531EG.)
Before beginning to operate this unit, please read the instruction manual
carefully in order to make sure that the best possible performance is obtained.
Introduction
Features
Safety Precautions ....................................................................................... 4
Features ....................................................................................................... 8
Contents ....................................................................................................... 9
Operating Precautions ............................................................................... 10
Name of Parts and their Functions ............................................................ 12
Ⅵ Realizing a High Picture Quality
This camera realizes 540 TV lines (standard) and S/N50 dB (standard) by
employing a highly sensitive CCD with 380,000 pixels (TK-C1530U) or 440,000
pixels (TK-C1530E/TK-C1531EG) and a high-resolution video processing circuit.
Setup
Ⅵ Day/Night surveillance
System Example ........................................................................................ 17
Flow for Connection/Settings ..................................................................... 19
Mounting the lens ....................................................................................... 20
Connecting the back panel ........................................................................ 22
Mounting the camera ................................................................................. 25
Adjusting the back focus ............................................................................ 28
Adjusting the lens ....................................................................................... 30
Adjusting the auto white balance ............................................................... 32
When the light is low, the camera automatically switches to high-sensitive
mode (B&W mode) to allow for day/night surveillance.
Ⅵ CRT/LCD monitor compatible
This camera is compatible for both CRT/LCD monitors. You can make settings
that are easier to view according to the type of monitor used.
Ⅵ Realizing sharper video images
The S.E.C (Smart Edge Control) function allows you to take sharper images.
How to read this manual
Setting
Menu basic operation ................................................................................. 34
The flow of menu screen ............................................................................ 36
AUX FUNCTION screen ............................................................................ 38
TITLE/VIDEO screen ................................................................................. 39
DISPLAY screen ........................................................................................ 49
LL ADJUSTMENT screen .......................................................................... 49
PRIVATE MASK screen ............................................................................. 50
COMMUNICATION screen ........................................................................ 51
MAINTENANCE screen ............................................................................. 52
FACTORY SETTING screen ...................................................................... 53
Ⅵ Conventions and symbols
Note
: Indicates operating precautions.
Memo
: Indicates reference data regarding limitations on functions,
usage and the like.
A
: Indicates a reference page or item.
● JVC holds the copyright to this manual. Any part or all of this manual may
not be reproduced without prior consent from the company.
● Product names of other companies described in this manual are
trademarks or registered trademarks of the respective companies.
Symbols such as ீ, ா and are omitted in this manual.
● Design, specifications and other contents described in this manual are
subject to change for improvements without prior notice.
Detailed setting
Camera title setting .................................................................................... 54
Manual adjustment of white balance .......................................................... 56
Output of B&W/Color switching signal ....................................................... 58
Control by B&W/Color switching signal from external ................................ 60
Private mask setting ................................................................................... 62
Scene file function ...................................................................................... 64
ⅷ Before starting an important recording, be sure to perform a test recording
in order to confirm that a normal recording is possible.
ⅷ We do not accept liability for the loss of a recording when recording is not
properly performed due to a problem in the video camera, VTR or video
tape.
ⅷ
We do not accept liability for any damage to the camera in cases where it is
dropped because of bad installation due to failure to observe the installation
instructions correctly. Please be careful when installing the camera.
Others
Specifications ............................................................................................. 66
8
9
Download from Www.Somanuals.com. All Manuals Search And Download.
Introduction
: Only for TK-C1530U/E and TK-C1531EG
Operating Precautions
Storage and Location of Use
Others
ⅷ This camera comes with a built-in AGC circuit. The sensitivity increases
automatically at a dark place and the screen may appear grainy. This is not
a malfunction.
ⅷ While the AGC is activated, if a transceiver which causes strong
electromagnetic wave is used near the camera, the picture may suffer from
beat.
ⅷ This camera has been designed for indoor use. When you use it outdoors,
be sure to use a housing or the like.
ⅷ Do not install or use the camera in the following places.
ⅷ Please use the camera more than five meters from such transceivers.
● In a place exposed to rain or moisture.
ⅷ You may hear some noise during power on and when the screen is
switched between the color and the black and white mode, because of the
movement of the optical filter switching motor. Also, the image will be
somewhat distorted.
ⅷ The beat may sometimes appear on the screen if gain is raised when the
line lock is in use, but the phenomenon takes place due to the fluctuation of
power frequency and is not a malfunction.
ⅷ When the COLOR OVERLAY is turned AONB, there may be an increase in
the color noises or changes in the colors. When such symptoms occur or
when infrared illumination is used, set COLOR OVERLAY to AOFFB (black
and white).
● In a place with vapor or oil, for example in a kitchen.
● When the ambient temperature rises above or falls below the acceptable
range (from -10 I to 50 I)
● In a place at which corrosive gases are emitted.
● Near a source of radiation, X-rays, strong radio waves or magnetism.
● In a place subject to vibration.
● In a place with excessive dirt.
ⅷ Using this unit or cables connected to this unit at places at which strong
radio waves and magnetism are emitted (e.g. near a radio, TV, transformer
or motor) may give rise to noises in the image and changes in its color.
ⅷ When this camera is used in the White Balance ATW (automatic tracking)
mode, the color tone may differ slightly from the actual color due to the
principle of the automatic tracking white balance circuit. This is not a
malfunction.
ⅷ If a high brightness object (such as a lamp) is shot, the image on the
screen may have white vertical tailings. This is a characteristic of the CCD
known as the smear phenomenon and is not a malfunction.
ⅷ When a high brightness object is shot, sometimes undulations can be
observed on the vertical lines of the object. However, this phenomenon is
peculiar to the camera and is not a malfunction.
Maintenance
ⅷ Turn off the power before performing maintenance.
ⅷ Clean the camera with a soft cloth. Wiping it with thinner or benzene may
melt the surface or cause it to fog. For tough stains, wipe using a cloth that
is dipped into a neutral detergent diluted with water, followed by wiping with
a dry cloth.
Energy Conservation
ⅷ When the camera is not in use for a long time, turn off the power of the
ⅷ Caution for operating the VIDEO IRIS lens
If the LEVEL dial of the VIDEO IRIS lens is set to a low level (L position), a
malfunction - such as the hunting phenomenon where the iris opens and
closes involuntarily - can occur. In such a case, first set the LEVEL dial on
the lens to the H position, and then adjust it to an optimum level while
checking the video signal.
system for safety and energy conservation reasons.
ⅷ The cable stopper on the terminal block can come off sometimes.
Therefore, be sure to take enough time and fix the cable securely.
ⅷ This camera achieves optical performance by using specified lens (1/3
inch size) conformed to CCD size. However, some general lens may not
meet this specification (effective image circle is small or optic displacement
is big). When such lens are used, negative effects such as shading may
occur.
11
10
Download from Www.Somanuals.com. All Manuals Search And Download.
Introduction
Note:
Name of Parts and their Functions
● Do not use a screw that is longer than the specified length. It may damage
the internal parts.
Front/Bottom/Side panel
D [IRIS] Iris Terminal
This is connected to an automatic iris control lens.
A
J
I
E [VIDEO,DC] Iris Selector Switch
This should be set according to the type of lens if an automatic iris control lens
is used.
B
VIDEO
DC
: In case of lens with EE amp built-in
: In case of lens without EE amp built-in
H
(Default setting: DC)
(A Pg. 20)
F [LEVEL] Iris Level Adjustment Dial
C
This adjusts the iris level of the automatic iris control lens. Usually, adjustment
is not required. When it is necessary, adjust the iris level according to the
condition of the object. (A Pg. 30)
To darken
To brighten
: Anti-clockwise direction (Towards L)
: Clockwise direction (Towards H)
D
G
IRIS
VIDEO
DC
G Rotation-preventive hole
E
F
Make use of this rotation-preventive hole to prevent any fall when mounting the
camera. Always make sure that the camera is securely mounted.
LEVEL
H Camera-mounting screw hole (1/4-20UNC)
A Back focus adjustment ring
Use this hole when mounting the camera onto a fixer, pan/tilt unit and the like.
This ring switches between back focus adjustment and lens mounting method.
When adjustment is required, loosen the back focus fastening screw J by
turning it anti-clockwise. After the adjustment, tighten the fastening screw by
turning it clockwise. This camera is factory-adjusted to a suitable position with
CS-mount lens. (A Pg. 28)
Use a screw shorter than 7 mm. (A Pg. 25)
Note:
● Do not use a screw that is longer than the specified length. It may damage
the internal parts.
B Lens Mount
I Camera-mounting bracket
To attach the lens. This is suitable for CS-mount lens (1/3 size) or C-mount
lens (1/3 size).
The bracket has been attached on the bottom of the camera before shipment.
It can also be attached on the top according to the circumstance. (A Pg. 26)
(A Pg. 20)
C Camera-mounting bracket fixing screws (x2: M2.6 x 6 mm)
J [BF LOCK] Back focus fastening screw
Be sure to use a 6 mm long screw.
This serves to fix the back focus adjustment mechanism. (A Pg. 28)
12
13
Download from Www.Somanuals.com. All Manuals Search And Download.
Introduction
: Only for TK-C1530U/E and TK-C1531EG
K [AC24V,DC12V] Power input terminal
Name of Parts and their Functions (continued)
To connect to AC 24 V or DC 12 V power supply.
(A Pg. 22)
A
B
C
L [TX+ ,TX- ,RX+ ,RX- ] Control signal connection terminal
D
Back panel
Terminal for inputting or outputting signals with electrical characteristics
conforming to the EIATIA RS-422A or RS-485 standard.
Ⅵ TK-C1530/TK-C925
M [AUX,GND] External terminal
This terminal is for the input/output signals that are set in the AUX MODE of
the AUX FUNCTION screen. (A Pg. 38)
S
CLASS 2 ONLY(U TYPE)
ISOLATED POWER ONLY(E TYPE)
SEE INSTRUCTION
MANUAL
● This terminal also outputs the B&W/Color signal. [Open-collector L signal.
R
POWER
K
Maximum voltage 25 V, current 30 mA]
● When switching B&W/Color using the control signal, the signals are input
+
INT
LL
DC12V d
AC24V H
-
1
2
Q
P
RX TERM-OFF
ON
through this terminal. [B&W: MAKE, Color: BREAK]
MENU
● When switching scene files using the control signal, the signals are input
through this terminal. (SCENE A and SCENE B only) (A Pg. 64)
SET
L
M
VIDEO OUT
N [VIDEO OUT] Video signal output connector
This connector outputs a composite video signal. Connect this to the video
input connector of a video monitor, switcher and the like.
O
N
SELECTOR
O [SELECTOR/SET] Selector switch/Set button
This allows user to select menu screens and change or confirm settings.
(A Pg. 34)
Press the SELECTOR switch up (J) and hold for 1 second to set to [FOCUS
ADJUST MODE] and open the lens iris for easy focusing. (As the depth of
object field is lower, focus can be adjusted accurately.)(A Pg. 28)
Ⅵ TK-C1531EG/TK-C926EG
P [MENU] Menu button
When pressed, a menu screen is brought up. (A Pg. 34)
S
R
T
SEE INSTRUCTION
MANUAL
POWER
INT
LL
ON
Q
P
RX TERM-OFF
MENU
SET
L
VIDEO OUT
O
N
SELECTOR
M
15
14
Download from Www.Somanuals.com. All Manuals Search And Download.
: Only for TK-C1530U/E and TK-C1531EG
Introduction
: Only for TK-C1530U/E and TK-C1531EG
Setup
Name of Parts and their Functions (continued)
System Example
Power
Cable
Q [RX TERM-OFF,ON/INT,LL] Function Selector Switch
ⅷ [RX TERM-OFF,ON] RX Signal Terminal ON/OFF Switch
TK-C1530U/E : AC24 V or DC12 V
TK-C1531EG : AC220 V-240V
Camera 1
DIGITAL
This sets whether or not the signal between RX+
control signal connection terminals L should be terminated at the value of
110K resistance.
and RX-
from the
C
D
Control Signal
Cable
MACHINE ID : 1
(MENU screen)
RX TERM : OFF
(Switch)
Video Signal Cable
ON
: Terminated at 110K.
OFF
: Not terminated at 110K.
Camera 2
DIGITAL
If the system including the camera is the MULTIDROP (Multi DROP, RS-485)
system, only the last camera mounted along the control signal cable is set to
AONB and the other cameras are set to AOFFB. (In the case of the
MULTIDROP system, it is necessary to set the MACHINE ID.)
If the system including the camera is the P TO P (Point to Point, RS-422A)
system, set this switch of all the cameras to AONB. To switch between
communication systems, use the item STYLE on the COMMUNICATION
screen. (A Pg. 51)
MACHINE ID : 2
(MENU screen)
RX TERM : OFF
(Switch)
Camera 8
(Default setting: ON)
DIGITAL
MACHINE ID : 8
(MENU screen)
RX TERM : ON
(Switch)
ⅷ [NT,LL] Selector Switch for Synchronizing System
This switch sets the synchronizing system for the camera.
INT
: This is set for internal synchronization (INT).
LL (Line Lock)
: This is set to synchronize the camera’s vertical
synchronization to the power frequency.
(Default setting: INT)
TO CAMERA
RX+ RX TX+ TX
DATA
I
/
O
UNIT
-
-
COM
1
2
3
4
5
6
7
8
COM 9/1 10/2 11/3 12/4 13/5 14/6 15/7 16/8 COM AUTO ALARM COMCASMWERACOM
SERIAL-1
SERIAL-2
VIDEO INPUT
1
1
2
3
3
4
4
5
6
6
7
7
8
MONITOR MONITOR
OUTPUT OUTPUT
1
2
1
2
3
4
5
6
7
8
Remote control unit and etc
2
5
8
ON
VIDEO OUTPUT
R [POWER] Power indicator lamp
This lamp lights up when power is supplied to the camera.
S Mounting Screw for Fall Prevention Wire
Use this screw when mounting the fall prevention wire to this unit. (Fall
prevention wire is not supplied with this product.)
Note:
● Connect the fall prevention wire to prevent this unit from falling accidentally.
Monitor
Memo:
T AC 220 V-240 V power cord
● Turn off the power of devices to be used before connecting the cables.
● Read through the “Instruction Manual” of the devices to be used carefully
before connecting.
This connects the camera to a commercial AC 220 V-240 V socket.
● For the types of connecting cables and the distances required, read
AConnecting the back panelB (A Pg. 22) carefully before connecting.
● Loop connection cannot be made for control signal cables.
16
17
Download from Www.Somanuals.com. All Manuals Search And Download.
: Only for TK-C1530U/E and TK-C1531EG
Setup
Flow for Connection/Settings
System Example (continued)
Follow the procedures below to connect/set this unit.
Turn off the power of devices to be used before connecting the cables.
Precautions when using RM-P2580E:
When operating a system using the RM-P2580E, several cameras (up to
16) can be connected and used on one control signal cable. Consequently,
an incorrect switch setting on just a single camera will cause the entire
system to work incorrectly.
Mounting the lens (A Pg. 20)
Mount the lens.
step 1
K
Confirm switch settings on the monitor screen using the following methods.
1. Confirm that the image from the camera to be checked is displayed
Connecting the back panel (A Pg. 22)
Connect the control signal cable, video signal coaxial cable
and the like.
on the monitor.
step 2
2. Turn ON the power of the camera to be checked.
The image is displayed on the monitor screen as shown below.
(When MACHINE ID is set to A05B)
K
Mounting the camera (A Pg. 25)
Mount the camera to the mounting location.
step 3
K
Adjusting the back focus (A Pg. 28)
Adjust the back focus.
PROTOCOL : DUPLEX ID-05
step 4
K
Confirm that ADUPLEXB is displayed
Check whether the ID is correct
3. Confirm that
correct.
ADUPLEXB is displayed and that the ID number is
Adjusting the lens (A Pg. 30)
Adjust the lens.
step 5
K
Memo:
● The number should be the same as the number of the VIDEO
INPUT terminal on the back panel of the RM-P2580E connecting the
camera to be checked.
step 6
Adjusting the auto white balance (A Pg. 32)
4. If the number is wrong, set the MACHINE ID again.
Memo:
● When controlling this camera with any system except the RM-P2580E,
perform proper settings using switches and menu screens according to the
system used.
18
19
Download from Www.Somanuals.com. All Manuals Search And Download.
Setup
1. Check the mounting method of the lens before mounting
Mounting the lens
● This camera is set to CS-mount lens before shipment. To use a C-mount
lens, loosen the back focus fastening screw with a screwdriver, turn the
back focus adjustment ring with your finger or the screwdriver and change
the mounting method.
1
● For the dimension (a) of the lens mounting section as illustrated in the
diagram, use the value that is shown in the table below.
(a)
F
Note:
● Never use one that exceeds the dimension (a) as it will damage the inner
part of the camera and will not allow normal installation. This will result in a
malfunction.
(b)
Lens
Flange back (b)
17.526 mm
12.5 mm
Dimension (a)
C-mount lens
CS-mount lens
5.5 mm or less
2. Turn the lens clockwise and mount it securely on the camera.
3. For an automatic iris control lens, select the switch on the side of this
camera according to the lens used.
3
VIDEO
DC
VIDEO : When using a lens with a built-in EE amplifier
DC
: When using a lens without a built-in EE amplifier
2
4. In the case of an automatic iris control lens, check the pin arrangement
and connect the lens cable to the socket.
IRIS
Ⅵ 4 pin plug
VIDEO
DC
LEL
COLOR VIDEO CAMERA
DC IRIS lens
VIDEO IRIS lens
4 pin plug
Pin
3
4
1
2
number
(Without built-in EE amplifier) (With built-in EE amplifier)
1
2
3
4
Brake (-)
Brake (+)
Drive (+)
Drive (-)
9.0 V (Max. 50 mA)
4
NC
VIDEO
GND
3
1
4
2
20
21
Download from Www.Somanuals.com. All Manuals Search And Download.
: Only for TK-C1530U/E and TK-C1531EG
Setup
: Only for TK-C1530U/E and TK-C1531EG
Note:
● If thin cables are used, the resistance of the cables will be high and a
significant voltage drop will occur when the camera is at its maximum
power consumption. Either use a thick cable with low resistance or place
the power supply near to the camera and shorten the length of the cable to
restrict the voltage drop at the rated current of camera to below 10 %. If
voltage drop occurs during operation, the performance will be unstable.
Connecting the back panel
Connect to AC 24 V or
Connect to AC 220 V – 240 V
power supply (TK-C1531EG/
TK-C926EG)
DC 12 V power supply
(TK-C1530U/E,
TK-C925U/E)
● Do not connect an AC 24 V cable to a commercial power supply. The
camera will be damaged. If the wrong cable is connected, the internal
circuit may be damaged. Do not use the camera. Bring it to your nearest
JVC dealer for inspection.
R
CLASS
2
ONLY(U TYPE)
SINSTRUCTION
MANUAL
ISOLATED POWER ONLY(E TYPE)
Ⅵ TK-C1531EG/TK-C926EG (AC 220 V-240 V)
POWER
Connect the power supply cable to the AC 220 V-240 V power supply.
+
DC12V
AC24V
d
INT
LL
-
1
2
H
RX TERM-OFF
ON
MENU
Note:
SET
● When you use this camera, the socket - outlet must be installed near the
equipment to make disconnect on easily.
VIDEO OUT
Monitor
SELECTOR
Video signal coaxial cable
Use either RG-59 or RG-11 coaxial cable (BNC).
Do not use other cables.
To the terminal of infrared illumination device etc.(A Pg. 24)
Connect to the TO CAMERA terminal of RM-P2580E
Connecting the control signal cables
Connecting the power cable
Ⅵ TK-C1530/TK-C925 (AC24 V or DC12 V)
Connect the control signal cables in a system where RM-P2580E is used.
A
As shown in the diagram below, connect the cables such that the TX+
and
TX-
B
signals and the RX+
C
and RX- signals are in pairs.
D
Connect the AC 24 V or the DC 12 V power cord to the power input terminal.
To prevent connection errors or a cable disconnection, we recommend the use
of lug plates.
A
TX+
Connect in pairs like this.
Connect in pairs like this.
B
TX
-
C
D
RX+
RX
-
The following table shows the connection distances when 2-core VVF !!!
(vinyl-insulated vinyl sheath cables) are used.
Memo:
● The use of 0.65 mm 4-core (2 pairs) twisted pair cables of impedance
110K is recommended.
The maximum connection distance with RM-P2580E is 1200 m. For
Maximum connection distance 60 m
150 m
240 m
380 m
RM-P2580E, several cameras (up to 16) can be connected to one cable but the
total extension of the cable must be within 1200 m. This is for the case when the
Conductor diameter 1.0R and 1.6R and 2.0R and 2.6R and
more more more more
conductor resistance of the cable is below 110K and its impedance is 110K
.
22
23
Download from Www.Somanuals.com. All Manuals Search And Download.
Setup
Connecting the back panel (continued)
Mounting the camera
When mounting the camera on a fixer, pan/tilt and the like, use the camera-
mounting screw hole located on the camera-mounting bracket.
Connecting alarm input/output terminal
Ⅵ Alarm input terminal
Camera-mounting
screw hole
Camera-mounting bracket fixing
screws (x2: M2.6 x 6 mm)
Connect infrared sensor, door sensor, metal sensor or sensor of manual
switch and the like.
● To prevent noise from entering the internal circuit, supply non-voltage
setting signal.
● Do not supply voltage.
● Can be set via menu whether to set to alarm when the contact is short
(MAKE), or when the contact is open (BREAK). (A Pg. 39)
● Supply such that the alarm signal continues for more than 200 ms. The
recognition of alarm signal may not be guaranteed if less than 200 ms.
IN
GND
CLASS
2
ONLY(U TYPE)
SEE INSTRUCTION
MANUAL
ISOLATED POWER ONLY(E TYPE)
POWER
+
INT
LL
ON
DC12V
AC24V
d
H
-
1
2
RX TERM-OFF
MENU
Rotation-preventive hole
Camera-mounting bracket
SET
VIDEO OUT
SELECTOR
IRIS
Ⅵ Alarm output terminal
VIDEO
DC
LEVEL
COLOR VIDEO CAMERA
Connect to alarm devices such as alarm, indicator, light or buzzer.
● As it is an open type collector output insulated by photocoupler, it will turn
on during alarm.
7 mm
or
less
● This terminal has polarity. Make sure to connect such as the voltage of +
terminal is higher than - terminal. It will be damaged if reverse voltage is
supplied.
OUT +
22ǡ
Note:
● Use a camera-mounting screw with a length shorter than 7 mm from the
camera-mounting face. Do not use a screw that is longer than the specified
length. It may damage the internal parts.
OUT -
24
25
Download from Www.Somanuals.com. All Manuals Search And Download.
Setup
1. Remove the camera-mounting bracket fastening screws (x2).
The camera-mounting bracket is removed from the camera.
2. Mounting the camera-mounting bracket on top of the camera
3. Mounting the camera onto a fixer, pan/tilt unit and the like
Mounting the camera (continued)
Mounting the camera-mounting bracket on top of the camera
The camera-mounting bracket is originally mounted at the bottom of the
camera before shipment but it can also be mounted on top of the camera.
Note:
● Use a camera-mounting screw with a length shorter than 7 mm from the
camera-mounting face. Do not use a screw that is longer than the specified
length. It may damage the internal parts.
● To mount the camera-mounting bracket on top of the camera, use the
1
screw holes on the back panel.
Fall Prevention
Use the black mounting screw on the back of the camera to install the fall
prevention wire
Camera-mounting
bracket
2
6mm
M3 x 6mm
2mm
E
D
VI
Fall Prevention Wire
Camera-mounting bracket
fastening screws
Precautions regarding fall prevention
● Special attention is required when installing the camera to the wall or
ceiling. You should not engage in the installation work yourself. Ask a
professional to do the job, since the fall of the camera can result in
injuries and accidents.
To mount the camera-
mounting bracket on top of
the camera, use the screw
holes on the back panel.
3
● When installing the camera on a fixer, pan/tilt unit and the like, make
sure to install it firmly using a rotation-preventive hole to prevent fall.
● To prevent fall, connect the camera to a section with sufficient strength
(ceiling slab or channel) using a fall prevention wire.
● Pay attention to the length, strength, routing and material (insulation
properties) of the fall prevention wire used.
IRIS
VIDEO
DC
LEVEL
● Use the black screw (M3 x 6 mm) on the back of the camera for the
installation of the fall prevention wire. Using other screws of different
sizes may damage the inside.
COLOR VIDEO
26
27
Download from Www.Somanuals.com. All Manuals Search And Download.
Setup
Adjusting the back focus
With a fixed-focus lens
If the focus cannot be adjusted correctly with the lens focus ring, adjust the
back focus as follows.
This camera is adjusted to a optimum wide range for CS-mount lens before
shipment but readjustment is required when using zoom lens or C-mount lens
or when the lens focus ring is out of focus. Use the following methods to adjust
the back focus.
1. Loosen the back focus fastening screw by turning it anti-clockwise
with a + screwdriver.
2. Shooting an object or a picture with fine patterns that is away from the
object
Back focus adjustment ring
3. Turn the lens focus ring to
∞.
4. Turn the back focus adjustment ring to focus at the best point.
5. Tighten the back focus fastening screw by turning it clockwise.
With a zoom lens
If the image is out of focus when zooming (telephoto - wide angle), adjust the
camera as follows.
Tighten
Loosen
1. Loosen the back focus fastening screw by turning it anti-clockwise
with a + screwdriver.
2. Shooting an object or a picture with fine patterns that is away from the
object
Back focus fastening screw (M2.6)
Lens focus ring
3. Zoom to the maximum telephoto position and turn the lens focus ring
to adjust the focus.
4. Zoom to the maximum wide angle position and turn the back focus
adjustment ring to adjust the focus.
5. Repeat steps 3 and 4 two or three times.
6. Tighten the back focus fastening screw by turning it clockwise.
Note:
● In the case of B&W/Color mode, the lens performance may cause the
image to be out of focus when the illumination of the object is near-infrared
light. In such a case, use a lens that is compatible with near-infrared light.
Memo:
● Focus setting may differ on the color and on the black and white screen.
Make adjustments so that the focus will come to the optimum on both
screens.
28
29
Download from Www.Somanuals.com. All Manuals Search And Download.
Setup
ⅷ LEVEL adjustment
Adjusting the lens
Monitor screen
To darken
LEVEL adjustment direction
Anti-clockwise (Towards L)
Clockwise (Towards H)
After the connection is complete, turn on the camera, display an image on the
monitor and check the video image.
In the case of an automatic iris control lens, the camera has been factory-
adjusted to the best position, but it may need to be adjusted according to the
condition of the object or the lens combination. If the image is unnatural, adjust it.
To brighten
Memo:
● Also read the instruction manual of the lens.
● If the LEVEL sensitivity adjustment is turned excessively to L, the
sensitivity increases because of the AGC function of the camera and the
image looks grainy.
Ⅵ With a VIDEO automatic iris lens (Automatic iris control lens with
built-in EE amplifier)
● Depending on the lens used, if the LEVEL dial is turned excessively to L,
the hunting phenomenon (floppy screen) where the iris opens and closes
involuntarily may occur. In such a case, first set the LEVEL dial to the H
position, and then readjust the LEVEL dial while checking the video signal.
Set the switch at the side of the camera to AVIDEOB and adjust the LEVEL dial
on the lens.
LEVEL adjustment
● To adjust the focus accurately, open the lens iris. Below is how to open the
lens iris for automatic iris lens.
● Press the [SELECTOR] switch on the back panel up (J) for 1 second.
[FOCUS ADJUST MODE] is displayed on the monitor screen.
● When the focus adjustment is completed, press either [SELECTOR]
switch (J, K, H, K), [MENU] or [SET] button.
DIGITAL
[FOCUS ADJUST MODE] display disappears and the lens iris returns
to original state.
Do not operate
● Connect the monitor TV to the VIDEO OUT terminal on the back panel and
Ⅵ With a DC automatic iris lens (Automatic iris control lens without
make adjustments.
built-in EE amplifier)
Set the Iris Selector Switch at the side of the camera to ADCB and adjust the
LEVEL with the Iris Level Adjustment Dial at the side of the camera.
IRIS
VIDEO
DC
LEVEL
COLOR VIDEO CAMERA
IRIS
VIDEO
DC
Iris Selector
Switch
Iris Level
Adjustment Dial
LEVEL
30
31
Download from Www.Somanuals.com. All Manuals Search And Download.
Setup
1. Place a white object at the center of the screen, under the same
lighting condition as the object to be shot and zoom in to fill the
screen with white.
Adjusting the auto white balance
Each light source has its own color temperature. Therefore, when the main
light source lighting an object is changed, press the SET button for a while and
adjust the white balance again.
2. Press the SET button for approx. one second.
Auto white balance adjustment begins. During operation, AAWC
OPERATIONB is displayed on the screen.
3. Adjustment is complete.
CLASS
2
ONLY(U TYPE)
SEE INSTRUCTION
MANUAL
ISOLATED POWER ONLY(E TYPE)
When the appropriate white balance is acquired, AAWC OKB is displayed.
POWER
+
DC12V
AC24V
d
INT
LL
ON
-
1
2
H
RX TERM-OFF
MENU
Ⅵ Error display
2
SET
When auto white balance adjustment is not successful, the following
messages will be blinking on the monitor.
VIDEO OUT
SET button
SELECTOR
AWC ERROR : NG OBJECT (Object error)
Displayed when there is not enough white color on an object or the color
temperature is not suitable.
Shoot a white object to fill the screen thoroughly and adjust the white balance
again.
3
AWC ERROR : LOW LIGHT (Insufficient Illumination)
Displayed when the light is low. Increase the illumination, then readjust the
white balance.
AWC OPERATION
AWC
OK
AWC ERROR : HIGH LIGHT (Excessive Illumination)
Displayed when the light is too bright. Decrease the illumination, then readjust
the white balance.
Ⅵ Error display
AWC ERROR:NG OBJECT
AWC ERROR : LOW LIGHT
Object error
Insufficient Illumination
AWC ERROR : HIGH LIGHT
Excessive Illumination
32
33
Download from Www.Somanuals.com. All Manuals Search And Download.
Download from Www.Somanuals.com. All Manuals Search And Download.
: Only for TK-C1530U/E and TK-C1531EG
Setting
: Only for TK-C1530U/E and TK-C1531EG
The flow of menu screen
36
37
Download from Www.Somanuals.com. All Manuals Search And Download.
: Only for TK-C1530U/E and TK-C1531EG
Setting
: Only for TK-C1530U/E and TK-C1531EG
Item
INPUT
POLARITY
Functions and settings
This sets the polarity of the AUX input signal.
AUX FUNCTION screen
MAKE
: When the contact between all alarm input
terminals and GND terminals changes from
open to close, the alarm will activate.
Item
Functions and settings
AUX MODE
This item sets the signal input or output of the AUX
terminal.
B&W OUT : A signal is output when the camera switches
to B&W or Color mode.
SCENE IN: Depending on the input signal of the AUX
terminal, the camera can switch between
scene files (A, B only).
BREAK : When the contact between all alarm input
terminals and GND terminals changes from
close to open, the alarm will activate.
[Setting: MAKE, BREAK]
[Default setting: MAKE]
Memo:
● When AUX MODE item is set to AB&W OUTB, A- - -B
will be displayed and settings is disabled.
IR IN
: Depending on the input signal of the AUX
terminal, the camera can switch between
B&W and Color mode. When there is an
alarm input, the mode will be B&W.
TITLE/VIDEO screen
T When the INPUT POLARITY item of the AUX
FUNCTION is AMAKEB
When the contact is short (MAKE), the mode is B&W.
When the contact is open (BREAK), the mode is
Color.
Item
Functions and settings
CAMERA
TITLE EDIT
This item sets the title to be displayed permanently on the
lower part of screen. A maximum of 24 characters can be
set for the title.
T When the INPUT POLARITY item of the AUX
FUNCTION is ABREAKB.
ACamera title settingB (A Pg. 54)
When the contact is open (BREAK), the mode is
B&W.
When the contact is short (MAKE), the mode is Color.
W.BALANCE
This item sets the white balance function.
Select AATWB when adjusting the white balance
according to the changes of the object, and select
AAWCB when shooting using adjusted white balance.
[Setting: SCENE IN, IR IN, B&W OUT]
[Default setting: B&W OUT]
Memo:
Memo:
● In B&W mode, A- - -B will be displayed and settings is
● Even when this item is set to B&W OUT, B&W OUT
will not output in B&W mode when the COLOR
OVERLAY item of B&W/COLOR is set to AONB. To
use B&W OUT signal in external illumination linkage,
set COLOR OVERLAY to AOFFB. (A Pg. 47)
disabled.
● During COLOR OVERLAYAONB or when COLOR
OVERLAY is functioning with AB&W/COLORB mode
set to AAUTOB, A- - -B is displayed and setting is
disabled. (A Pg. 47)(A Pg. 44)
● The switching of scene files by AUX input is for 2
scenes AA,BB only. Switching to SCENE C, SCENE D
requires operation from external
ATW
This is the Auto-Tracking White Balance mode.
(Automatic color temperature tracking.) The camera
adjusts the white balance automatically according to the
color temperature of the illumination.
communication.AScene file functionB (A Pg. 64)
ATW(WI
DE)
This mode supports an even wider range of color
temperature than ATW. Use this mode when white
balance cannot be achieved under a light source such as
high pressure sodium lamp.
38
39
Download from Www.Somanuals.com. All Manuals Search And Download.
Setting
TITLE/VIDEO screen (continued)
Item
Functions and settings
SHUTTER
(continued)
Item
W.BALANCE
AWC
Functions and settings
MANUAL This sets a shutter speed when MANUAL is set.
SPEED
(continued)
TK-C1530U/TK-C925U
[Setting: NORMAL, 1/100, 1/250, 1/500, 1/1000, 1/2000,
1/4000, 1/10000]
[Default setting: NORMAL]
AWC SET:
The Auto White Control (automatic white balance
adjustment) mode adjusts the white balance
automatically.
TK-C1530E/TK-C1531EG/TK-C925E/TK-C926EG
[Setting: NORMAL, 1/120, 1/250, 1/500, 1/1000, 1/2000,
1/4000, 1/10000]
Display during AWC
operation
Meaning of display
[Default setting: NORMAL]
AWC OPERATION
AWC OK
AWC in operation
Memo:
AWC completed normally
● When SHUTTER item is set to AAUTOB, A- - -B will be
displayed and settings is disabled.
AWC ERROR : NG OBJECT
AWC completed outside
range
AUTO
LIMIT
This sets the fastest value of a shutter speed when AUTO
is set.
AWC ERROR : HIGH LIGHT
AWC ERROR : LOW LIGHT
AWC completed with
overlighting
TK-C1530U/TK-C925U
[Setting: 1/100, 1/250, 1/500, 1/1000, 1/2000, 1/4000,
1/10000, 1/20000, 1/40000, 1/100000]
AWC completed with low
lighting
R GAIN : Adjusts the R (red) hue during AWC. The
larger the number, the redder the color
becomes.
[Default setting:1/100000]
TK-C1530E/TK-C1531EG/TK-C925E/TK-C926EG
[Setting: 1/120, 1/250, 1/500, 1/1000, 1/2000, 1/4000,
1/10000, 1/20000, 1/40000, 1/100000]
[Setting:0 to 255]
B GAIN : Adjusts the B (blue) hue during AWC. The
larger the number, the bluer the color
becomes.
[Default setting:1/100000]
Memo:
[Setting:0 to 255]
● When SHUTTER item is set to AMANUALB, A- - -B will
be displayed and settings is disabled.
● The higher the shutter speed becomes, the more
smear phenomenon is emphasized, which is peculiar
to the CCD.
SHUTTER
MODE
This item sets the electronic shutter.
Select the mode of the electronic shutter.
MANUAL: This operates in the shutter speed set in the
MANUAL SPEED item.
AUTO : This automatically switches the shutter speed
according to brightness. The fastest value of a
shutter speed is set in the AUTO LIMIT item
(A Pg. 41).
[Default setting: MANUAL]
40
41
Download from Www.Somanuals.com. All Manuals Search And Download.
Setting
TITLE/VIDEO screen (continued)
Item
Functions and settings
GAIN
(continued)
Item
Functions and settings
MAX
GAIN
This item sets a maximum gain of the AGC (Automatic
Gain Control).
GAIN
This item sets the gain.
0(OFF) : No AGC function.
Memo:
HIGH
: Increase the gain up to a maximum of 26dB
according to the illumination of an object.
● If the gain is increased, the screen appears grainy in
a dark place.
SUPER : Increase the gain up to a maximum of 32dB
according to the illumination of an object.
[Default setting: HIGH]
MODE
Select the gain adjustment mode. Sensitivity increases
electronically for an object with low illumination.
AGC (Automatic Gain Control)
: This automatically adjusts the electronic gain
according to the illumination of the object.
FIXED (Fixed gain)
: This operates in the gain set in the FIX GAIN
item regardless of the illumination of the object.
[Default setting: AGC]
Memo:
● When the MODE item of B&W/COLOR is set to
AAUTOB, the MODE item becomes AAGCB [(AGC) is
displayed] but AHIGH/SUPERB can be selected.
When it is set to A0(OFF)B, AHIGHB will be selected
automatically.
● When MODE item is set to AFIXEDB, A- - -B will be
displayed and settings is disabled.
Memo:
● When the MODE item of B&W/COLOR is set to
AAUTOB, this item becomes AGC [(AGC) is
displayed].
FIX
GAIN
This sets the value of fixed gain when MODE is set to
AFIXEDB.
[Setting: 0 to 20]
[Default setting: 10]
Memo:
● When MODE item is set to AAGCB, A- - -B will be
displayed and settings is disabled.
42
43
Download from Www.Somanuals.com. All Manuals Search And Download.
: Only for TK-C1530U/E and TK-C1531EG
Setting
Item
Functions and settings
TITLE/VIDEO screen (continued)
B&W/COLOR
(continued)
“COLOR” display differs depending on the model.
MODE
(continu
ed)
[Default setting: COLOR]
Display for TK-C1530U/TK-C925U. For TK-C1530E/
TK-C1531EG/TK-C925E/TK-C926EG, COLOUR is displayed.
“COLOR” is displayed for TK-C1530U/TK-C925U and “COLOUR” is displayed
for TK-C1530E/TK-C1531EG/TK-C925E/TK-C926EG.
Z
From this point onwards, “COLOR” will be used for indication.
Memo:
Item
Functions and settings
To ensure a successful B&W/Color switching
B&W/COLOR
(TK-C1530U/
TK-C925U)
This item sets the mode switching of B&W and Color.
● If the MODE item of B&W/COLOR is set to AAUTOB,
the B&W/Color setting can be switched according to
the brightness of the object, but the condition of
illumination and field angle may make this impossible.
To be absolutely certain of B&W/Color switching, we
recommend you to input signals of an external sensor
(available separately) to the alarm terminal of this
camera before switching.
Memo:
● When switching the Color mode to B&W mode, the
type of light source may cause the focus to be
dislocated. This is because the B&W mode is
sensitive to both visible light and near-infrared light.
When this happens, adjust the focus again in B&W
mode.
B&W/COLOUR
(TK-C1530E/
TK-C1531EG/
TK-C925E/
TK-C926EG)
● Use infrared illumination if necessary.
MODE
This sets the function to switch from Color to B&W mode.
The options change according to the setting of AUX
MODE item in AUX FUNCTION (A Pg. 38).
AUX MODE setting
B&W OUT
SCENE IN
IR IN
MODE options
COLOR,B&W,AUTO
COLOR,B&W,AUTO
(AUX IN)
COLOR : Sets the camera permanently to Color mode.
B&W : Sets the camera permanently to B&W mode.
AUTO : The camera automatically switches to Color
mode when the object is bright and B&W
mode when it is dark.
44
45
Download from Www.Somanuals.com. All Manuals Search And Download.
: Only for TK-C1530U/E and TK-C1531EG
TITLE/VIDEO screen (continued)
Item
Functions and settings
B&W/COLOR
(continued)
Item
Functions and settings
COLOR
This function gives a pseudo color to the image under
natural lighting such as moonlight or low brightness light.
Color reproducibility is poor under artificial illumination
such as infrared lamp and halogen light. In such a case,
select AOFFB for this function.
OVERLAY
(TK-C1530U)
B&W/COLOR
(continued)
AUTO
LEVEL
When the MODE item is set to AAUTOB, this function sets
the signal level of the object where the camera will switch
to B&W mode.
: Switches to B&W mode when the signal level
of the object indicates low illumination.
NORMAL: Switches to B&W mode when the signal level
of the object indicates normal illumination.
: Switches to B&W mode when the signal level
of the object indicates high illumination.
[Default setting: NORMAL]
COLOUR
OVERLAY
[Setting: OFF, ON]
(TK-C1530E/
TK-C1531EG)
[Default setting: OFF]
LOW
Memo:
● Even when the MODE item of AUX FUNCTION is set
to AB&W OUTB, B&W OUT will not be output when
this item is set to AONB. To use B&W OUT signal in
external illumination linkage, set this item to AOFFB.
(A Pg. 38)
HIGH
Z
Display for TK-C1530U/TK-C925U. For TK-C1530E/
TK-C1531EG/TK-C925E/TK-C926EG, COLOUR is displayed.
Memo:
● When MODE item of B&W/COLOR is set to AAUTOB,
A- - -B will be displayed and settings is disabled.
AUTO
TIME
When the MODE item is set to AAUTOB, this function sets
the time required to switch to the B&W/Color mode.
Example : When set to 30s, the camera will switch to
B&W mode 30 seconds after it has become
dark.
[Setting: 10s,20s,30s]
[Default setting: 30s]
Memo:
● When MODE item of B&W/COLOR is set to AAUTOB,
A- - -B will be displayed and settings is disabled.
47
46
Download from Www.Somanuals.com. All Manuals Search And Download.
: Only for TK-C1530U/E and TK-C1531EG
Setting
DISPLAY screen
TITLE/VIDEO screen (continued)
Item
Functions and settings
Item
Functions and settings
MONITOR
TYPE
This sets the monitor type.
BLC MODE
Sets the backlight compensation function. Set this item
when there is a bright light source in the background of
the object and the object becomes dark in the automatic
iris function. Set such that unnecessary light source is
outside the photometry area.
You can change the output video settings according to
the type of monitor used. Select an appropriate mode.
[Setting: CRT,LCD1,LCD2]
[Default setting: CRT]
OFF
: No backlight compensation.
AREA1 to AREA4 : Refer to the diagram below to set
the item.
LL ADJUSTMENT screen
[Default setting: OFF]
Item
Functions and settings
V.PHASE
This adjusts the vertical synchronization to those of other
cameras when a selector switch for the synchronizing
system on the back of the camera is at ALLB.
OFF
AREA 1
AREA 2
AREA 3
AREA 4
TK-C1530U/TK-C925U
This item can only operate in a region with a power
frequency of 60 Hz.
Photometry
area
[Setting: -131 to 0 to 131]
[Default setting: 0]
IRIS MODE
This item sets the setting for automatic iris operation.
AUTO : Automatic iris is enabled.
OPEN : Forces the automatic iris to open.
[Default setting: AUTO]
TK-C1530E/TK-C1531EG/TK-C925E/TK-C926EG
This item can only operate in a region with a power
frequency of 50 Hz.
[Setting: -156 to 0 to 156]
[Default setting: 0]
Memo:
● This setting does not function when a manual iris lens
Memo:
is used.
● When set to AINTB, A- - -B will be displayed and
settings is disabled.
S.E.C (Smart
Edge Control)
This item emphasizes images with very fine and detailed
parts. This will increase the visual resolution of the
image.
[Setting: ON, OFF]
[Default setting: OFF]
Memo:
● Some objects may cause the image noise to be
significant.
48
49
Download from Www.Somanuals.com. All Manuals Search And Download.
: Only for TK-C1530U/E and TK-C1531EG
Setting
: Only for TK-C1530U/E and TK-C1531EG
COMMUNICATION screen
PRIVATE MASK screen
This item sets the control signal connection terminals at the back of the camera.
If the setting is changed, be sure to close the menu screen before switching on
the power again. The screen display when power is switched on differs
according to the setting of this item.
Item
Functions and settings
MASK No.1
MASK No.2
MASK No.3
MASK No.4
This function masks parts of an image in gray display
such that the masked parts will not be shown on the
screen.
Select AONB and press the SET button. The MASK EDIT
screen appears and mask settings can be made. APrivate
mask settingB (A Pg. 62)
Item
TYPE
Functions and settings
This sets whether the communication with the control
device is bi-directional or unidirectional. Select the setting
according to the device to be connected.
SIMPLEX : Select this to connect an unidirectional
communication control device.
DUPLEX : Select this to connect a bi-directional
communication control device.
ON : Private mask is enabled.
OFF : Private mask does not display.
[Default setting: OFF]
[Default setting: DUPLEX]
STYLE
This sets a communication system. Select the setting
according to the system used.
P TO P (Point to Point)
:This is set when a remote control unit controls a camera.
MULTIDROP
:This is set when a remote control unit controls multiple
cameras.
[Default setting: P TO P]
MACHINE ID This is set when the STYLE item is set to AMULTIDROPB.
This number identifies individual cameras in a group. This
item does not operate properly if an ID number is repeated
within a system.
When used in combination with RM-P2580E, set the item
together with the VIDEO INPUT number of RM-P2580E.
When STYLE item is set to P TO P, A- - -B will be displayed
and settings is disabled.
[Setting: 1 to 99]
Ⅵ
Screen display when power is switched on
Memo:
● Only the following 4 types are
Monitor screen
displayed.
● DUPLEX
● DUPLEX ID-TT
● SIMPLEX
● SIMPLEX ID-TT
(TT indicates that MACHINE
ID setting is required)
PROTOCOL : DUPLEX ID-05
TYPE display
Only displayed when the
STYLE item is MULTIDROP
50
51
Download from Www.Somanuals.com. All Manuals Search And Download.
Setting
MAINTENANCE screen
FACTORY SETTING screen
White spots may appear on the screen due to changes in properties with time.
This is a general characteristic of CCDs. This camera has a built-in white spot
compensation function to reduce these white spots.
The values set on the menu are returned to the default settings.
Item
Functions and settings
Item
Functions and settings
CANCEL
Does not return to the default setting. The screen returns
to the main menu.
CCD SPOT
SCAN
CANCEL
: No white spot compensation. The screen
returns to the main menu.
EXECUTE : Starts CCD spot detection.
CLEAR(WITH
OUT TITLE)
Returns settings except titles to the default setting.
Memo:
● Once default setting is returned, the screen
automatically returns to the main menu.
Memo:
● The white spot compensation function of this camera
does not completely compensate white spots.
● Maximum number of compensation is 32.
CLEAR(ALL)
Returns all settings including titles to the default setting.
● White spots may not be compensated due to its
Memo:
properties.
● Once default setting is returned, the screen
automatically returns to the main menu.
● As white spot compensation is interpolated from the
surrounding pixels, the camera may not acquire
accurate image information when the object has very
fine pattern.
● The result of white spot compensation is maintained
until the next compensation.
52
53
Download from Www.Somanuals.com. All Manuals Search And Download.
Detailed setting
2. Press the SELECTOR switch up, down, left or right (J,
K
,
H
,
I) and
select a character from the character area.
Camera title setting
The selected character is displayed flashing on and off.
A title can be selected for each camera. (Maximum 24 characters)
3. Press the SET button
The first character is confirmed and the blinking title input area moves to
the second character.
CLASS
2
ONLY(U TYPE)
SEE INSTRUCTION
MANUAL
ISOLATED POWER ONLY(E TYPE)
POWER
4. Repeat steps 2. to 3.
+
DC12V
AC24V
d
INT
LL
ON
-
It is possible to use up to 24 characters to input the camera title.
5. Press the MENU button
MENU button
1
2
H
RX TERM-OFF
MENU
SET
The new camera title is saved and the top menu (TITLE/VIDEO screen) is
displayed.
To set multiple camera titles, repeat steps 1. to 5.
VIDEO OUT
SELECTOR
SET button and SELECTOR switch
Ⅵ How to operate
1. Select the item CAMERA TITLE EDIT on the TITLE/VIDEO screen and
press the SET button.
Menu operation
CLR+SET
State
The CAMERA TITLE EDIT screen is displayed.
The first character from the character area flashes on and off and is ready
for input.
Clears all entered text.
CANCEL+SET
Cancels the edited setting and returns to the previous
state.
TITLE/VIDEO
CAMERA TITLE EDIT..
SCENE Z
[O]+SET
[N]+SET
INS+SET
DEL+SET
Moves the input frame of the title input area one step
to the left.
E
W. BALANCE
SHUTTER..
GAIN..
B&W/COLOR..
BLC MODE
ATW
Moves the input frame of the title input area one step
to the right.
OFF
Inserts one space and moves subsequent characters
to the right.
<MENU>RETURN <SET>SUB MENU
TITLE/VIDEO screen
Deletes the character selected by the cursor and
moves subsequent characters one step to the left.
Space
Character area
Flashing
Only displayed in TK-C1530E/TK-C1531EG
CAMERA TITLE EDIT screen
Input frame
Title input area
54
55
Download from Www.Somanuals.com. All Manuals Search And Download.
Download from Www.Somanuals.com. All Manuals Search And Download.
: Only for TK-C1530U/E and TK-C1531EG
Detailed setting
: Only for TK-C1530U/E and TK-C1531EG
Ⅵ Set the B&W/COLOR item to AUTO
Output of B&W/Color switching signal
1. Select the item B&W/COLOR on the TITLE/VIDEO screen and press
the SET button.
It is possible to output B&W/Color switching signal from the AUX terminal on
the back of this camera.
B&W/Color switching signal is output by setting both the AUX MODE and
B&W/COLOR items.
The B&W/COLOR screen is displayed.
2. Press the SELECTOR switch up or down (J, K) and select MODE.
3. Press the SELECTOR switch left or right (H, I) and set to AUTO.
Ⅵ Set the AUX MODE item to AB&W OUTB
TITLE/VIDEO
SCENE
Z
CAMERA TITLE EDIT..
1. Select the item AUX FUNCTION on the main menu screen and press
W. BALANCE
SHUTTER..
GAIN..
AWC
the SET button.
The AUX FUNCTION screen is displayed.
E
B&W/COLOR..
BLC MODE
IRIS MODE
S.E.C.
OFF
AUTO
OFF
2. Press the SELECTOR switch up or down (J, K) and select AUX MODE.
3. Press the SELECTOR switch left or right (H, I) and set to B&W OUT.
<MENU>RETURN <SET>SUB MENU
TITLE/VIDEO screen
MENU
E
AUX FUNCTION..
TITLE/VIDEO..
SCENE
A
B&W/COLOR
MODE
AUTO LEVEL
AUTO TIME
SCENE
COLOR
- - -
Z
B&W/COLOR
MODE
AUTO LEVEL
AUTO TIME
SCENE
AUTO
NORMAL
30s
Z
DISPLAY..
E
E
LL ADJUSTMENT..
PRIVATE MASK..
COMMUNICATION..
MAINTENANCE..
- - -
COLOR OVERLAY
OFF
COLOR OVERLAY
OFF
FACTORY SETTINGS..
<MENU>EXIT
<SET>SUB MENU
Main menu screen
<MENU>RETURN
<MENU>RETURN
B&W/COLOR screen
AUX FUNCTION
E
AUX MODE
INPUT POLARITY
B&W OUT
- - -
4. Press the MENU button twice.
The setting is complete and the screen returns to the main menu.
Memo:
● Even when AUX MODE is set to AB&W OUTB, B&W OUT will not output in
B&W mode when the COLOR OVERLAY item of B&W/COLOR is set to
AONB. To use B&W OUT signal in external illumination linkage, set COLOR
OVERLAY item to AOFFB.
<MENU>RETURN
AUX FUNCTION screen
● When near-infrared illumination is used, a B&W screen may switch to a
color screen if the object reflects light excessively. To perform switching
with higher accuracy, we recommend that you use the settings mentioned
in AControl by B&W/Color switching signal from externalB (A Pg. 60).
4. Press the MENU button twice.
The setting is complete and the screen returns to the normal screen.
● In the case of B&W/Color mode, the lens performance may cause the
image to be out of focus when the illumination of the object is near-infrared
light. In this case, use a lens that is compatible with near-infrared light.
58
59
Download from Www.Somanuals.com. All Manuals Search And Download.
Detailed setting
: Only for TK-C1530U/E and TK-C1531EG
Ⅵ When performing only B&W/Color mode switching without changing
other video settings
Control by B&W/Color switching signal from external
1. Select the item AUX MODE on the AUX FUNCTION screen.
You can use the switching signal from an external control device to link the
B&W/Color switching or near-infrared illumination of this camera.
Consult your nearby JVC’s dealer on the connecting devices.
2. Press the SELECTOR switch left or right (H, I) and set to
AIR INB.
Example)
AUX MODE
: IR IN
AUX FUNCTION
INPUT POLARITY
: In the case of MAKE (A Pg. 38)
E
AUX MODE
INPUT POLARITY
IR IN
MAKE
B&W : MAKE signal
Color : BREAK signal
CLASS
2
ONLY(U TYPE)
SEE INSTRUCTION
MANUAL
ISOLATED POWER ONLY(E TYPE)
<MENU>RETURN
POWER
Infrared illumination
AUX FUNCTION screen
+
INT
LL
DC12V
AC24V
d
H
-
1
2
RX TERM-OFF
ON
MENU
SET
VIDEO OUT
SELECTOR
Sensor or switch
External control device
Ⅵ To switch AGC and SHUTTER settings together with B&W/Color
mode switching
Make individual settings for B&W and Color in ASCENE AB and ASCENE
BB and set AUX MODE in AUX FUNCTION to ASCENE INB.
For details, see AScene file functionB (A Pg. 64).
Memo:
● In the case of B&W/Color mode, the lens performance may cause the
image to be out of focus when the illumination of the object is near-infrared
light. In this case, use a lens that is compatible with near-infrared light.
CLASS ONLY(U TYPE)
ISOLATED POWER ONLY(E TYPE)
2
SEE INSTRUCTION
MANUAL
POWER
+
DC12V
AC24V
d
H
INT
LL
-
MENU button
1
2
RX TERM-OFF
ON
MENU
SET
VIDEO OUT
SELECTOR
SET button and SELECTOR switch
61
60
Download from Www.Somanuals.com. All Manuals Search And Download.
: Only for TK-C1530U/E and TK-C1531EG
Detailed setting
: Only for TK-C1530U/E and TK-C1531EG
Ⅵ Setting a mask area
1. Select a MASK No., use the SELECTOR switch (H, I) to select AONB
and press the SET button (If AOFFB is selected, private mask will not
be displayed.)
Private mask setting
Perform private mask setting to mask images that you do not want to be shown
on the screen in gray.
You can set 4 locations in the display screen.
The PRIVATE MASK EDIT screen is displayed.
2. Editing the mask
Ⅵ Selection of mask number
Edit left/top or right/bottom of mask respectively.
1. Select the item PRIVATE MASK on the main menu screen and press
Memo:
the SET button.
● Use SET button to switch between left/top or right/bottom of editing of
mask.
The PRIVATE MASK screen is displayed.
2. Select a mask number with SELECTOR switch (J, K).
● Use the SELECTOR switch (H, I) to edit the left and right position
3. Select
AONB with SELECTOR switch (H, I) and press the SET button (If
(horizontal width) of the mask.
A
OFF is selected, private mask will not be displayed.)
B
● Use the SELECTOR switch (J, K) to edit the top and bottom position
(height) of the mask.
The PRIVATE MASK EDIT screen is displayed.
Masks are available from MASK No.1 to MASK No.4. Use according to the
mask position.
●
MASK EDIT
No.
1
MASK EDIT
No. 1
Use SET
button to
switch
MENU
AUX FUNCTION..
TITLE/VIDEO..
SCENE
A
DISPLAY..
LL ADJUSTMENT..
PRIVATE MASK..
COMMUNICATION..
MAINTENANCE..
<MENU>RETURN <SET>MODEQN
<MENU>RETURN <SET>MODEPO
E
PRIVATE MASK EDIT screen
PRIVATE MASK EDIT screen
FACTORY SETTINGS..
<MENU>EXIT
<SET>SUB MENU
No.1
No.3
No.2
No.4
Ⅵ Completion of mask setting
Main menu screen
1. Press the MENU button
PRIVATE MASK
MASK No . 1..
The mask area of the selected number is saved and the screen returns to
the top menu (PRIVATE MASK screen).
E
ON
MASK No . 2
MASK No . 3
MASK No . 4
OFF
OFF
OFF
Select a mask number and set the mask area in all the desired masks (from
MASK No.1 to MASK No.4).
Mask position for each number
Memo:
● Maximum 4 masks can be set.
<MENU>RETURN <SET>SUB MENU
PRIVATE MASK screen
62
63
Download from Www.Somanuals.com. All Manuals Search And Download.
: Only for TK-C1530U/E and TK-C1531EG
Detailed setting
: Only for TK-C1530U/E and TK-C1531EG
Memo:
● All 4 scene files can be set. (SCENE A to SCENE D)
● Only 2 scenes, SCENE A and SCENE B, can be switched in AUX terminal
setting (A Pg. 38).
Use external communication to switch 4 files from SCENE A to SCENE D.
For details, consult your nearby JVC dealer.
● Items that can be set in a scene file are as follows.
Scene file function
This camera has 4 types of scene files (SCENE A to SCENE D) for detailed
video settings according to the shooting condition of the object.
Scene files can be switched using AUX terminal input (SCENE A, SCENE B
only) or external communication (SCENE A to SCENE D).
Ⅵ Switching day/night video settings with the scene file function
MAIN MENU
Example) AUX MODE
: SCENE IN
INPUT POLARITY : In the case of MAKE (A Pg. 38)
(A Pg. 39)
TITLE/VIDEO
Items that are saved in scene files
SCENE A (Day)
AWC EXECUTE
When AWC is
selected
CAMERA TITLE EDIT
(A Pg. 39)
MAKE signal
W.BALANCE
W.BALANCE
ADJUST
AWC SET
R GAIN
B GAIN
(A Pg. 39)
SHUTTER
MODE
MANUAL SPEED
AUTO LIMIT
Setting example for day
use
CAMERA TITLE:DAY
GAIN setting
(A Pg. 40)
GAIN
MODE
MAX GAIN
FIX GAIN
MODE
MAX GAIN
: AGC
:HIGH
(A Pg. 42)
ZDisplay for TK-C1530U.
COLOUR is displayed for
TK-C1530E/TK-C1530E/
TK-C1531EG
Switch depending on the input
signal from AUX
B&W/COLORZ
MODE
AUTO LEVEL
AUTO TIME
(A Pg. 44)
SCENE B (Night)
BLC MODE
COLORZ OVERLAY
(A Pg. 48)
BREAK signal
IRIS MODE
(A Pg. 48)
S.E.C.
(A Pg. 48)
Setting example for night
use
CAMERA TITLE :NIGHT
GAIN setting
GAIN
FIX GAIN
:FIXED
:20
64
65
Download from Www.Somanuals.com. All Manuals Search And Download.
Others
Ⅵ Lens
Specifications
Lens Mount
: C/CS mount
Ⅵ Camera
Ⅵ General
Signaling method
TK-C1530U/TK-C925U : NTSC
TK-C1530E/TK-C1531EG/TK-C925E/TK-C926EG
: PAL
Power supply
TK-C1530U/TK-C925U
TK-C1530E/TK-C925E
: AC 24 V 60 Hz, DC 12 V
: AC 24 V 50 Hz, DC 12 V
Image pickup device
: 1/3 type IT CCD
TK-C1531EG/TK-C926EG : AC220 V - 240 V 50 Hz/60 Hz
Color imaging method
Power consumption
: Single color-difference line sequential system, 2:1
interlace
TK-C1530U
TK-C1530E
TK-C1531EG
: 5.0 W
: 420 mA
: 77 mA
TK-C925U
TK-C925E
: 4.8 W
: 400 mA
Imaging area
TK-C926EG : 75 mA
: 4.8 mm (H)
ן 3.6 mm (V), (diagonal 6 mm) Ambient temperature
Operation : -10 I to 50 I (14 g to 122 g)
Recommended : 0 I to 40 I (32 g to 104 g)
Scanning frequency
TK-C1530U/TK-C925U : 15.734 kHz (horizontal), 59.94 Hz (vertical)
TK-C1530E/TK-C1531EG/TK-C925E/TK-C926EG
: 15.625 kHz (horizontal), 50 Hz (vertical)
Effective pixels
TK-C1530U/TK-C925U : 380,000 pixels,768 (H) x 494 (V)
TK-C1530E/TK-C1531EG/TK-C925E/TK-C926EG
: 440,000 pixels,752 (H) x 582 (V)
Humidity
:
Mass
TK-C1530U/E, TK-C925U/E : Approx. 480 g
TK-C1531EG, TK-C926EG
: Approx. 700 g
Synchronization method
Accessories
: Internal (INT)/Power synchronization (LL)
TK-C1530U/
TK-C925U
: Instructions .................................................................... 1
Warranty Card................................................................ 1
Service Information Card............................................... 1
Video S/N ratio
: 50 dB (Standard, AGC OFF, White 50 % output)
TK-C1530E/TK-C1531EG/TK-C925E/TK-C926EG
: Instructions .................................................................... 2
Horizontal resolution
: 540 TV lines (standard)
Communication
: RS-422/RS-485
Video output
: VBS 1 V (p-p) ,75 K
Minimum brightness of object
Color mode
B&W mode
: 0.7 lx (F1.2, AGC SUPER, 50 % output)
: 0.08 lx (F1.2, AGC SUPER, 50 % output)
66
67
Download from Www.Somanuals.com. All Manuals Search And Download.
Others
TK-C1531EG
Specifications (continued)
Ⅵ Dimensions [Unit: mm]
TK-C1530U/E
126
115
U1-32
126
115
U1-32
65
65
42
1/4-20UNC
42
1/4-20UNC
30
30
T Specifications and appearance of this camera and related products are
subject to change for improvements without notice.
68
69
Download from Www.Somanuals.com. All Manuals Search And Download.
|