Invacare Telephone 5143B User Manual

Service Manual  
DEALER: Keep this manual. The procedures in this manual MUST  
be performed by a qualified technician.  
84 inch Bed Extension (5143B)  
1 General  
Check all parts for shipping damage. In case of damage, DO NOT use. Contact Carrier/Invacare for  
further instructions.  
To ensure the safe installation of the crossover cable service kit, these instructions must be followed:  
1.1 Symbols  
Signal words are used in this manual and apply to hazards or unsafe practices which could result in  
personal injury or property damage. See the information below for definitions of the signal words.  
WARNING  
ƽ
Warning indicates a potentially hazardous situation which, if not avoided, could  
result in death or serious injury.  
CAUTION  
Caution indicates a potentially hazardous situation which, if not avoided, may result  
in property damage or minor injury or both.  
Gives useful tips, recommendations and information for efficient, trouble-free use.  
1.2 Tools Required:  
Two 1/2 inch open end wrenches; one vice grip  
1.3 Kit includes the following:  
7000M465 Extension Weldment L.H., Qty 1; 7000M466 Extension Weldment R.H., Qty 1  
7000M469 Pull Tube End Assembly (5143/5143IVC), Qty 1  
553000M699 Link Fabric Extension with Open Hooks Attached, Qty 2  
53000M701Instruction Sheet, Qty 1  
53000M434 Bi-way Locknut, Qty 2  
54000M6412 5/16-18 x 1-inch Bolt, Qty 2  
51000M135 Helical Spring, Qty 4  
1176192 Bed Extender Sub Assembly, Qty 1  
1
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
3. Separate link fabric by raising the head end and disengage the open end hooks that secure the head  
and foot springs together.  
I
L
H
I
J
J
K
K
4. From the head end (H), lift up on the bed frame (I) and disengage the rivets (J) on the corner plates  
out of the corner locks (K) of the head end of bed.  
5. From the foot end (L), lift up on the bed frame (I) and disengage the rivets (J) on the corner plates  
out of the corner locks (K) of the foot end of bed.  
6. Lay bed on side and rotate head and foot spring sections to a 90° angle.  
This will allow you to disengage head spring from foot spring.  
2.2 Attach the Four Inch Extension  
A
B
1. Attach four-inch extension (A) to the right and left hand sides of the foot spring frame (B) using  
5/16-18 x 1 inch bolt and bi-way locknut. Securely tighten.  
2. Reassemble foot spring to head spring.  
C
E
D
C
When performing STEP 3, make sure the open-end hooks are positioned down  
towards the ground/floor.  
3. Attach the six open-end hooks (C) of the link fabric extension (D) to the existing link fabric of the  
foot spring (E).  
4. Attach one helical spring (F) to one end of the link fabric extension (D).  
5. Attach the opposite end of the helical spring (F) to one of the four mounting holes in the four-inch  
extension (A).  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
D
F
I
A
H
6. Attach second helical spring (F) to the mounting hole (H) into the four inch extension (A) on other  
side of bed frame.  
7. Using vise grips (I), secure the helical spring (F) to the link fabric extension (D).  
J
D
C
8. To connect the link fabric extension (D) to the head spring (J), manually raise the head spring and  
attach open-end hooks (C) to the head spring.  
Make sure open end of hooks (C) are positioned down towards the ground/floor.  
9. Attach bed ends to head and foot spring assemblies.  
L
K
10. Using the existing drive shaft (K), slide the bed extender sub-assembly (L) on either end and attach  
drive shaft to head and foot boards.  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
M
Assembled View  
M
O
N
11. Remove existing pull tube (M) in head motor assembly or head crank assembly  
12. Install pull tube furnished with this kit in the following manner:  
For beds equipped with AC motors, use the first spring button (N)  
For beds equipped with DC motors, use the second spring button (O).  
E
F,G  
13. Reconnect pull tube (E) to head spring drive arm using the clevis (G) and cotter (F) pins.  
Bed requires an 84-inch mattress.  
If assistance is required or any problems are encountered during the conversion,  
contact customer service at 1-800-333-6900  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
NOTES  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
NOTES  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
Invacare Corporation  
USA  
© 2011 Invacare Corporation. All rights  
reserved. Republication, duplication or  
modification in whole or in part is  
prohibited without prior written  
permission from Invacare. Trademarks are  
identified by ™ and ®. All trademarks are  
owned by or licensed to Invacare  
Corporation or its subsidiaries unless  
otherwise noted.  
One Invacare Way  
Elyria, Ohio USA  
44036-2125  
440-329-6000  
800-333-6900  
Technical Services  
440-329-6593  
800-832-4707  
Part No 53000M701  
Rev G - 09/11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 

Ingersoll Rand Automobile Parts 61588 100 User Manual
Intellinet Network Solutions Switch 503358 User Manual
Jet Tools Saw JWBS14DXPRO User Manual
John Deere Spreader SS1023B User Manual
Jonsered Chainsaw CS 2240 User Manual
JVC Stereo System CA MXDVA5 User Manual
JVC VCR LPT0816 001A User Manual
Kambrook Hot Beverage Maker KSK400 User Manual
Kenwood Car Stereo System UKDC X7533U User Manual
Kodak Camera Lens P825 User Manual