Invacare®
I-Transia™
I-Transia 205 kg (450 lb), I-Transia 250
kg (550 lb)
User Manual
This manual MUST be given to the user of
the product.
BEFORE using this product, read this
manual and save for future reference.
Download from Www.Somanuals.com. All Manuals Search And Download.
Contents
1
4
7
8
4
4
5
5
5
Troubleshooting
Maintenance and Safety
2
6
6
Information . . . . . . . . . . . .
General . . . . . . . . . . . . .
Pinch Points and
6
6
9
7
8
8
Interference. . . . . . . . . . . .
8
9
3
4
Emergency
Resetting the
5
6
Download from Www.Somanuals.com. All Manuals Search And Download.
I-Transia™
1 General
1.1 Symbols
Signal words are used in this manual and apply to hazards or unsafe practices which could
result in personal injury or property damage. See the information below for definitions
of the signal words.
WARNING!
– Warning indicates a potentially hazardous situation which, if not avoided, could
result in death or serious injury.
CAUTION!
– Caution indicates a potentially hazardous situation which, if not avoided, may
result in property damage or minor injury or both.
IMPORTANT
– Indicates a hazardous situation that could result in damage to property if it is
not avoided.
Gives useful tips, recommendations and information for efficient, trouble-free use.
Emergency Stop
Emergency Lowering Function
Reset emergency stop
Danger — rotating parts
This product complies with Directive 93/42/EEC concerning medical devices.
The launch date of this product is stated in the EC declaration of conformity.
Type B in accordance with IEC/EN 60601–1
Read the manual before use.
1.2 Intended Use
I-Transia is a hoist which covers the need for lifting or moving a person with disabilities in the
home care sector, nursing homes, rehabilitation centres, and institutions.
4
1183377-B
Download from Www.Somanuals.com. All Manuals Search And Download.
General
1.3 Conditions for Use
The use of the I-Transia ceiling hoist is subject to the following:
•
•
The I-Transia should only be used by trained personnel.
The safe working load (SWL), 205 kg (450 lbs) or 250 kg (550 lbs), must not be
•
The instruction offered by Invacare to all customer groups in connection with the
purchase of a ceiling-mounted hoist has been received.
•
•
The caregiver pays attention to the well-being of the user when using the hoist.
The hoist is used in rail systems which are installed, tested and approved according to
DS/EN 10535 and Invacare’s stipulations.
•
•
•
Only technicians who have been certified by Invacare may install and test the rail systems.
The hoist is used with an Invacare hanger bar.
The hoist is used with an Invacare lifting sling or with other suitable slings. Refer to
1.4 Service Life
The I-Transia has an expected lifetime of 15 years, on the condition of correct use and
correct service inspections. Refer to the I-Transia user manual for more information.
1.5 Features
Information panel on the I-Transia bottom surface
Type and maximum load designation
Green/yellow battery indicator lamp
A
B
C
Strap for activating emergency stop and
emergency lowering device
Button for resetting the emergency stop
D
1183377-B
5
Download from Www.Somanuals.com. All Manuals Search And Download.
I-Transia™
2 Safety
2.1 General Guidelines
WARNING!
– Read and understand these instructions. DO NOT use this product without
reading and understanding these instructions. If you need help with these
instructions, contact a healthcare professional or an Invacare dealer.
Otherwise injury or damage may occur.
ACCESSORIES WARNING
– Invacare products can only be used with accessories made by Invacare.
Accessories not made by Invacare have not been tested by Invacare.
Accessories not made by Invacare should not be used.
Check all parts for shipping damage before using. In case of damage, DO NOT use the
equipment. Contact your Invacare dealer for further instructions.
The information contained in this document is subject to change without notice.
2.2 Operating Information
This section of the manual contains general safety information about your product. For
specific safety information, refer to the appropriate section of the manual and procedures
within that section.
General
WARNING!
Risk of Falling
DO NOT attempt any transfer without the consent of the patient's healthcare
providers. Read this user manual and observe other personnel lifting patients.
Then practice lifting under supervision with a capable person acting as a patient.
– Use common sense in all lifts. Special care MUST BE taken with people with
disabilities who cannot cooperate while being lifted.
– Check that the sling attachments are secure on the hanger bar each time the
sling is removed and replaced, to ensure that the sling is properly attached
before the patient is removed from a stationary object.
WARNING!
– Read the instructions carefully before using the I-Transia and in connection
with cleaning and service of the hoist.
– The I-Transia’s maximum load must never be exceeded.
– The I-Transia may only be used to lift or move a person.
– The red strap for the emergency stop and the emergency lowering must be
adjusted to the caregiver’s reach, and must not be removed.
– If the I-Transia fails while in use, stop using the hoist, transfer the patient using
a different method and contact an Invacare dealer for repair by a certified
technician.
– The I-Transia is controlled by a microprocessor PCB, which can be damaged
by static electricity if touched without the necessary precautions,
6
1183377-B
Download from Www.Somanuals.com. All Manuals Search And Download.
Safety
WARNING!
– The electronics may only be serviced by certified service technicians
– For safety reasons the side cover may only be dismantled when the emergency
stop is activated.
– This product is mechanically protected against derailing and jamming.
– The hand control is protected against water splashes (IPX4). DO NOT
immerse the hand control in liquids, even for a short time. Avoid any contact
with water or other liquids.
Pinch Points and Positioning
WARNING!
Risk of Injury
Pinch points are present on the strap carabiner A and fingers could be pinched.
The hanger bar B can move suddenly and cause injury.
– ALWAYS keep hands and fingers clear of moving parts to avoid injury.
– When positioning the hoist, be aware of the position of the hanger bar B
and the patient. Injury could occur.
1183377-B
7
Download from Www.Somanuals.com. All Manuals Search And Download.
I-Transia™
2.3 Load Limits
Read the label which indicates the maximum load limits for each component.
The component, e.g. hanger bar, lifting sling, etc. labelled with the lowest load limit
determines the maximum load limit for the entire system.
This maximum load limit must not be exceeded.
Please note that the max load may change when different components are used, such
as hanger bars, lifting slings, etc.
2.4 Power Supply
I-Transia is equipped with a battery that requires regular recharging. The power supply for
the transformer and the charging station must be connected by a certified technician.
The transformer supplied must always be used.
Refer to for more information about the power supply.
2.5 Radio Frequency Interference
WARNING!
– Most electronic equipment is influenced by Radio Frequency Interference
(RFI). CAUTION should be exercised with regard to the use of portable
communication equipment in the area around such equipment. If RFI causes
erratic behavior, stop the unit using the hand control or emergency stop. DO
NOT use the unit while transmission is in progress.
8
1183377-B
Download from Www.Somanuals.com. All Manuals Search And Download.
I-Transia™
Hand control
Hanger Bar
The hanger bar label is located near the end of the hanger bar, to the inside
of the hooks.
10
1183377-B
Download from Www.Somanuals.com. All Manuals Search And Download.
Setup
3 Setup
3.1 Included Items
1. I-Transia hoist*
2. Hand control
3. Transformer
4. Charging station
5. Side covers
6. Hanger bar
*The hoist includes the lifting strap, carabiner and trolley.
3.2 Installing the Hanger Bar Before Use
WARNING!
Risk of Injury
Pinch points are present on the strap carabiner B and fingers could be pinched.
The hanger bar A can move suddenly and cause injury.
– ALWAYS keep hands and fingers clear of moving parts to avoid injury.
– When positioning the hoist, be aware of the position of the hanger bar B
and the patient. Injury could occur.
1183377-B
11
Download from Www.Somanuals.com. All Manuals Search And Download.
I-Transia™
The hanger bar A can be installed to the lifting strap carabiner B without the use of tools.
1. Pull and hold the retainer C up toward the pin D.
2. Move the pin and retainer down to open the carabiner B.
3. Install the hanger bar A onto the carabiner.
4. Release the retainer and pin.
5. Before use, ensure the hanger bar is installed completely onto the carabiner and the
retainer is in place, as shown in the figure.
3.3 Before Use
I-Transia is delivered with the emergency stop activated in order to ensure that the battery is
not being discharged during long-term storage (more than six months). Reset the emergency
12
1183377-B
Download from Www.Somanuals.com. All Manuals Search And Download.
Operation
4 Operation
4.1 Indicator lamps and audio signals
Status
Indicator
lamps
Audio
signals
Possible I-Transia Functions
Up
Down
Emergency
Lowering
Off-stand by
All OK
Off
Green
Yellow
Yellow
ü
ü
ü
ü
ü
ü
ü
Low battery
Fault on hoist
Beeps at
button
activation
Battery critical
low
Yellow
Green
ü
ü
ü
ü
Over load
Beeps at
button
activation
4.2 Operating the Hoist
The I-Transia is switched on automatically when a button on the hand control is
pressed.
The I-Transia will switch off automatically after approximately 8 minutes of
non-operation.
1. Press the UP button A on the hand control B to lift the patient.
2. Press the DOWN button C to lower the patient.
There must be a load on the lifting strap corresponding to the weight of the hanger
bar before I-Transia’s lowering function will operate.
1183377-B
13
Download from Www.Somanuals.com. All Manuals Search And Download.
I-Transia™
4.3 Charging the Battery
The I-Transia battery charges when the hand control is placed in the charging
station.
The indicator lamp on the bottom of the hoist turns yellow if the charge status
becomes low. Finish the current lift in progress and charge the batteries when
finished.
The hoist is charged when the indicator lamp on the bottom of the hoist is green.
Always leave the hand control in the charging station when the I-Transia is not in
use. This guarantees I-Transia functionality and maintains the battery to ensure a
long lifetime.
The transformer must be connected and switched on before charging can take
place. A green indicator lamp on the transformer indicates it is connected and
switched on.
1. Tilt the hand control A and place it on the two pins B on the charging station C.
2. Push the rubber handle D into the opening on the charging station.
An audible “beep” indicates that the hand control is placed correctly.
4.4 Emergency stop and lowering strap
WARNING!
– If the emergency stop or lowering strap must be used, there is a problem
with the system. Contact your Invacare dealer for service before using the
system again.
14
1183377-B
Download from Www.Somanuals.com. All Manuals Search And Download.
Operation
The red strap A on the underside of the hoist B has the following functions:
•
•
Emergency stop
Emergency lowering
Emergency stop
Pull and release the red strap A to activate the emergency stop function if the hoist B does
not stop or react to the hand control during use.
Lifting/lowering functions are deactivated. Emergency lowering will not stop.
The hoist will not function until the emergency stop is reset.
The green lamp C will turn off.
1183377-B
15
Download from Www.Somanuals.com. All Manuals Search And Download.
I-Transia™
Emergency lowering
The emergency lowering function is used to lower the patient if the hoist stops working.
1. Pull and hold the red strap A to lower the patient.
2. Release the red strap to stop lowering the patient.
The emergency stop feature is activated when the strap is released.
3. If the hoist system needs service, contact your Invacare dealer for service.
16
1183377-B
Download from Www.Somanuals.com. All Manuals Search And Download.
Operation
Resetting the emergency stop
The yellow reset button A pops out when the red strap B has been pulled. The hoist will
not function until the emergency stop is reset.
1. Press the yellow button on the bottom of the hoist to reset the emergency stop or
lowering feature.
2. Activate the hand control twice to resume use of the hoist.
1183377-B
17
Download from Www.Somanuals.com. All Manuals Search And Download.
I-Transia™
5 Lifting the Patient
5.1 Sling Information
WARNING!
Invacare shall not be liable for damage or injury that may occur as a result of
using slings made by other manufacturers.
Invacare shall not be liable for damage or injury due to incorrect use of the sling
or inadequate attention by the caregiver or user.
– Use the sling that is recommended by the individual’s healthcare team for the
comfort and safety of the individual that is being lifted. If there is any doubt
about the selection or use of a sling, please contact your Invacare dealer.
A sling with four to six lifting straps designed for mounting on hooks should be used when
using a Invacare hanger bar.
Refer to the sling user manual for more details about the slings.
UK Customers — Please see the Invacare bulletin concerning slings. A copy can be obtained
from Invacare UK — 01656 776222 or [email protected].
5.2 Attaching the Sling
CAUTION!
Be careful when attaching the lifting sling on the hooks.
– Check that the straps have been positioned completely onto the hooks of the
hanger bar.
– When pressing the up button to lift the user, check again that all the straps
remain correctly placed in the hanger bar’s hooks.
1. Place the uppermost set of straps from the back of the sling on the hooks A on the
hanger bar B.
2. Place the lowest set of straps from the legs of the sling on the hooks on the hanger bar.
Refer to the sling user manual for proper positioning of the person in the sling and
proper positioning of the straps on the hanger bar.
18
1183377-B
Download from Www.Somanuals.com. All Manuals Search And Download.
Lifting the Patient
5.3 Lifting Information
WARNING!
Only personnel who have received training regarding the use of lifting equipment
and fitting of slings should use the hoist.
– Plan the move. Avoid leaving the user in the sling unattended.
– The I-Transia lifts quickly. Before lifting, check that the user is completely
free of his/her surroundings.
– The user’s head, arms, hands and feet must not be in danger of becoming
trapped.
– Be careful with any tubes and wires that are attached to the user.
– Check that the red emergency strap, hand control and hand control cable are
free of the hanger bar, user and other objects before the hoist is activated
and moved up or down.
– When the hoist is used correctly, the user should only be lifted to the extent
that she/he is clear of the surface and should be moved at this height.
5.4 Lifting to and from a seated position
Follow this procedure when lifting a person from a seated position (wheelchair, commode,
etc.).
1. Move the I-Transia towards the person to be lifted.
2. Position the hanger bar at the same height as the person’s chest and no closer than
mid-thigh.
3. Position the hanger bar so it is parallel to the person’s shoulders.
4. Position the person in the sling. Refer to the sling user manual.
5.5 Lifting to and from a lying position
Follow this procedure when lifting a person from a lying position (in bed).
1. Move the I-Transia towards the person to be lifted.
2. Position the hanger bar over the center of the person.
3. Position the hanger bar so it is parallel to the person’s shoulders.
4. Position the person in the sling. Refer to the sling user manual.
5. Elevate the head of the bed, so that the user is sitting up.
1183377-B
19
Download from Www.Somanuals.com. All Manuals Search And Download.
I-Transia™
6 After Use
6.1 Transport and Storage
Invacare recommends that the I-Transia is always transported and stored in the original
packaging.
For long term storage, the emergency stop must be activated. Refer to Emergency stop, page
15. This will prevent the discharge of the battery.
The I-Transia should be stored as indicated by the packaging symbols in the table.
Packaging
Symbol
Storage Condition
Temperatures between –10 and +40°C (14 and 104°F)
Relative Air Humidity between 30 and 70%
Air Pressure between 700 and 1060 hPa
This Side Up
6.2 Disposal
WARNING!
Environmental Hazard
This product has been supplied from an environmentally aware manufacturer
that complies with the Waste Electrical and Electronic Equipment (WEEE)
Directive 2002/96/CE.
This device contains NiMH batteries.
This product may contain substances that could be harmful to the environment if
disposed of in places (landfills) that are not appropriate according to legislation.
– DO NOT dispose of batteries in normal household waste. They MUST
be taken to a proper disposal site. Contact your local waste management
company for information.
– Please be environmentally responsible and recycle this product through your
recycling facility at its end of life.
20
1183377-B
Download from Www.Somanuals.com. All Manuals Search And Download.
After Use
Environmental Policy Statement
Invacare is continuously working towards ensuring that the company's impact on the
environment, locally and globally, is reduced to a minimum. It is Invacare’s goal to:
•
•
Comply with the current environmental legislation (e.g. WEEE and REACH directives)
Ensure that we, at the widest possible range, use RoHS compliant materials and
components
•
•
Ensure that our products do not have an unnecessary negative impact on the
environment regarding use, recirculation or disposal
Ensure that our products contribute to a positive working environment in the places
they are utilised
Inspections are made annually by the Department for Nature and Environment from the
Municipality of Aarhus using the Danish Environmental Protection Act, section 42 as a
reference.
1183377-B
21
Download from Www.Somanuals.com. All Manuals Search And Download.
I-Transia™
7 Troubleshooting
7.1 Troubleshooting Table
SYMPTOMS
PROBLEM
SOLUTION
Emergency stop is activated. Check that the emergency
stop is not activated.
I-Transia hoist does not
respond to the hand control’s
keys.
System does not have power Check that the I-Transia has
or battery is discharged
power supply and that the
battery is recharged.
Check that the transformer
is switched on and connected
to the charging station.
Place the hand control in the
charging station and recharge
the I-Transia.
Trolley does not traverse.
Hoist will not charge
Rails require service or
cleaning.
System does not have power Place the hand control in the
charging station and recharge
Contact an Invacare dealer
for service.
the I-Transia
Check that the power supply
is switched on and connected
to the charging station.
Contact an Invacare dealer
for service.
No indicator light on hoist
System does not have power Check that the I-Transia has
or battery is discharged.
power supply and that the
battery is recharged.
Check that the power supply
is switched on and connected
to the charging station.
Place the hand control in the
charging station and recharge
the I-Transia.
The emergency lowering cord Hoist requires service.
does not turn hoist off
Contact an Invacare dealer
for service.
The emergency lowering cord Hoist requires service.
does not lower the hoist.
Contact an Invacare dealer
for service.
If problems are not remedied by the suggested means, please contact your
Invacare dealer.
22
1183377-B
Download from Www.Somanuals.com. All Manuals Search And Download.
Maintenance
8 Maintenance
8.1 Safe Maintenance
WARNING!
Regular maintenance of patient lifts and accessories is necessary to assure
proper operation.
– Maintenance MUST be performed only by a certified technician.
8.2 Maintenance and Safety Inspection
Service Interval
At normal daily operation, a service check-up should take place every year, according to
the Safety Inspection Checklist in the Service Manual. When performing annual or regular
maintenance, all parts designed to carry load must be, as a minimum, tested with load. All
safety features must be checked according to EN ISO 10535:2006 Annex B. This inspection
must be performed by a certified technician.
LOLER Statement
The UK Health and Safety Executive’s Lifting Operations and Lifting Equipment Regulations
1998, require any equipment that is used in the workplace to lift a load be subject to
safety inspection on a six monthly basis. Please refer to the HSE web site for guidance
The person responsible for the equipment must ensure adherence to LOLER regulations.
General Maintenance
Follow the maintenance procedures described in this manual to keep your patient
lift in continuous service.
The hoist is designed to provide a safe, efficient and satisfactory service with minimum care
and maintenance.
It is important to inspect slings, hanger bar, carabiner and lifting strap for signs of cracking,
fraying, deformation or deterioration. If damage is found, DO NOT use. Contact your
Invacare dealer IMMEDIATELY.
If you question the safety of any part of the lift, contact your Invacare dealer immediately and
advise him/her of your problem.
Replacement of parts must only be performed by a certified technician.
1183377-B
23
Download from Www.Somanuals.com. All Manuals Search And Download.
I-Transia™
Daily Inspections
The hoist should be checked each time it is used. Perform the following checks in addition to
those performed in the annual service inspection. If you question the safety of any part of the
lift, DO NOT use. Contact your Invacare dealer IMMEDIATELY.
q
q
Visually inspect the sling, hanger bar and lifting strap. Check all parts for damage or
wear. If damage is found, DO NOT use. Contact your Invacare dealer IMMEDIATELY.
Check the emergency stop and emergency lowering function. Check all parts for
external damage or wear. If damage is found, DO NOT use. Contact your Invacare
dealer IMMEDIATELY.
q
Check that all hardware and attachment points for damage or wear. Check all parts for
external damage or wear. If damage is found, DO NOT use. Contact your Invacare
dealer IMMEDIATELY.
q
q
q
q
Verify that the hand control is functional.
Check the battery charger.
Charge the battery every day the lift is used.
Check the carabiner for wear at the bottom contact point A. Do not use the hoist if the
carabiner measures less than 6 mm (1/4 in) at this point.
Safety Inspection Checklist
The annual safety inspection checklist is available in the I-Transia service manual.
8.3 Cleaning the Sling and Hoist
Cleaning the Sling
Refer to the washing instructions on the sling and to the sling manual for cleaning details.
Cleaning and Disinfecting the Hoist
To prevent cross-infection, the parts of the hoist that come in contact with caregivers and
patients must be cleaned and disinfected.
A soft cloth, dampened with water and a small amount of dish liquid, is all that is needed
to clean the hoist, lifting strap and carabiner. The hoist can be cleaned with non-abrasive
cleaners.
Never use acids, alkaline or solvents for cleaning the hoist. Dry the hoist carefully after
cleaning.
The hoist, hand control and mounting parts can be damaged if the hoist is cleaned any other
way than stated above.
The hoist must be wiped with a moistened, firmly wrung cloth with ordinary household
disinfectants. Only use disinfection detergents approved by the facility.
24
1183377-B
Download from Www.Somanuals.com. All Manuals Search And Download.
Technical Data
9 Technical Data
9.1 Typical Product Parameters
Classification
Non-permanent installation with out protective ground.
Mobile equipment is class II equipment (marked with
double-encased symbol) and can be connected to the mains
direct by the user.
Class II equipment
Equipment is disconnected from the supply mains by
detaching the mains plug from the wall outlet.
Flammability
This equipment is not suitable for use in the presence of
flammable mixtures.
Flammability
Liquid Ingress
Lifting module
Hand control
Charging station
Power supply
IP 44
IP 44
IP 20
IP 20
Functions
Lifting capacity, Safe Working
Load (SWL)
205 kg (450 lb), 250 kg (550 lb)
Operation
Sound level
Hand control
52 dB (A)
Lifting Speed
85 kg (187 lb) load
40 mm/sec. (1.6 in/sec)
40 mm/sec.(1.6 in/sec)
40 mm/sec.(1.6 in/sec)
80 mm/sec.(3.2 in/sec)
150 kg (330 lb) load
Safe Working Load, SWL
Max. 5 kg (11 lb) load
Weight and materials
Safe Working Load (SWL)
Hoist weight
205 kg (450 lb), 250 kg (550 lb)
8.0 kg (17.6 lb)
Covers, top and bottom
Impact-resistant UL 94 V-0 flame retardant recyclable plastic
1183377-B
25
Download from Www.Somanuals.com. All Manuals Search And Download.
I-Transia™
Dimensions
580 mm (22.8 in)
350 mm (13.8 in)
156 mm (6.1 in)
184 mm (7.2 in)
83 mm (3.3 in)
A
B
C
D
E, min
F, min
G
415 mm (16.3 in)
2500 mm (98.4 in)
Depth of hoist 194 mm (7.6 in )
Safety
Emergency stop
Yes
Emergency lowering device
Control of lifting strap
Cut-off angle
Yes, electrical
Yes
45° along the rail, 10° across the rail.
Electronics
Automatic when used. Soft star/stop
Automatic
Automatic
On/off
Overload protection
Low battery protection
Power supply
36 V DC, 0.83 A
Supply voltage, transformer
Battery
100–240 V AC, 47–63 Hz
24 V NiMH, 2.8 Ah
Continuous operation with
short time loading with 3
hours without recharging
Max number of lifts in series
with 85 kg (187 lb)
10/90% (2 min. operation 18 min. pause)
55/1000 mm
Max number of lifts in series
with SWL [205 kg (450 lb),
250 kg (550 lb)]
Max charging time at 25°C
(77°F)
28/1000 mm
3 hrs
Operating temperature
10°C — 35°C (50°F — 95°F)
26
1183377-B
Download from Www.Somanuals.com. All Manuals Search And Download.
Warranty
10 Warranty
10.1 Limited Warranty — Europe
Terms and conditions of the warranty are part of the general terms and conditions particular to the individual
countries in which this product is sold.
In order to comply with Health & Safety regulations and to ensure that Invacare employees are not exposed
to the risk of infection, we must insist that all products returned for repair are thoroughly cleaned. Any
product sent to Invacare which appears to be contaminated will be rejected and disposed of immediately at
the customer’s expense.
10.2 Limited Warranty — North America
PLEASE NOTE: THE WARRANTY BELOW HAS BEEN DRAFTED TO COMPLY
WITH FEDERAL LAW APPLICABLE TO PRODUCTS MANUFACTURED AFTER
JULY 4, 1975.
This warranty is extended only to the original purchaser/user of our products.
This warranty gives you specific legal rights and you may also have other legal rights which vary from state to
state.
Invacare warrants the products manufactured to be free from defects in materials and workmanship for a period
of one year from the date of purchase. If within such warranty period any such product shall be proven to be
defective, such product shall be repaired or replaced, at Invacare’s option. This warranty does not include any
labor or shipping charges incurred in replacement part installation or repair of any such product. Invacare’s sole
obligation and your exclusive remedy under this warranty shall be limited to such repair and/or replacement.
For warranty service, please contact the dealer from whom you purchased your Invacare product. In the event
you do not receive satisfactory warranty service, please write directly to Invacare at the address on the back
cover, provide dealer’s name, address, date of purchase, indicate nature of the defect.
Invacare Corporation will issue a serialized return authorization. The defective unit or parts MUST be returned
for warranty inspection using the serial number, when applicable as identification within 30 days of return
authorization date. Do not return products to our factory without our prior consent. C.O.D. shipments will be
refused; please prepay shipping charges.
LIMITATIONS AND EXCLUSIONS: THE FOREGOING WARRANTY SHALL NOT APPLY TO SERIAL
NUMBERED PRODUCTS IF THE SERIAL NUMBER HAS BEEN REMOVED OR DEFACED, PRODUCTS
SUBJECTED TO NEGLIGENCE, ACCIDENT, IMPROPER OPERATION, MAINTENANCE OR STORAGE,
PRODUCTS MODIFIED WITHOUT INVACARE’S EXPRESS WRITTEN CONSENT (INCLUDING, BUT NOT
LIMITED TO, MODIFICATION THROUGH THE USE OF UNAUTHORIZED PARTS OR ATTACHMENTS;
PRODUCTS DAMAGED BY REASON OF REPAIRS MADE TO ANY COMPONENT WITHOUT THE
SPECIFIC CONSENT OF INVACARE, OR TO A PRODUCT DAMAGED BY CIRCUMSTANCES BEYOND
INVACARE’S CONTROL, AND SUCH EVALUATION WILL BE SOLELY DETERMINED BY INVACARE. THE
WARRANTY SHALL NOT APPLY TO PROBLEMS ARISING FROM NORMAL WEAR OR FAILURE TO
ADHERE TO THE INSTRUCTIONS IN THIS MANUAL.
THE FOREGOING WARRANTY IS EXCLUSIVE AND IN LIEU OF ANY OTHER EXPRESS WARRANTIES.
IMPLIED WARRANTIES, IF ANY, INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY
AND FITNESS FOR A PARTICULAR PURPOSE, SHALL NOT EXTEND BEYOND THE DURATION OF
THE EXPRESSED WARRANTY PROVIDED HEREIN AND THE REMEDY FOR VIOLATIONS OF ANY
IMPLIED WARRANTY SHALL BE LIMITED TO REPAIR OR REPLACEMENT OF THE DEFECTIVE PRODUCT
PURSUANT TO THE TERMS CONTAINED HEREIN. INVACARE SHALL NOT BE LIABLE FOR ANY
CONSEQUENTIAL OR INCIDENTAL DAMAGES WHATSOEVER.
SOME STATES DO NOT ALLOW EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL
DAMAGE, OR LIMITATION ON HOW LONG AN IMPLIED WARRANTY LASTS, SO THE ABOVE
EXCLUSIONS AND LIMITATIONS MAY NOT APPLY TO YOU.
THIS WARRANTY SHALL BE EXTENDED TO COMPLY WITH STATE OR PROVINCIAL LAWS AND
REQUIREMENTS.
1183377-B
27
Download from Www.Somanuals.com. All Manuals Search And Download.
Notes
Download from Www.Somanuals.com. All Manuals Search And Download.
Notes
Download from Www.Somanuals.com. All Manuals Search And Download.
Notes
Download from Www.Somanuals.com. All Manuals Search And Download.
United Kingdom
Ireland
Invacare Limited • Pencoed Technology Park, Pencoed, Bridgend
CF35 5AQ • Tel: (44) (0) 1656 776 222 • Fax: (44) (0) 1656 776
Invacare Ireland Ltd • Unit 5 Seatown Business Campus • Seatown
Road • Swords • County Dublin – Ireland • Tel : (353) 1 810 7084 •
Australia
Invacare Australia Pty Ltd. • 1 Lenton Place • North Rocks • NSW
2151 • Australia • Tel: (61) 2 8839 5333 • Fax: (61) 2 8839 5353 •
New Zealand
France
Invacare New Zealand • 4 Westfield Place • Mt. Wellington •
Auckland • New Zealand • Tel: (64) 9 917 3939 • Fax: (64) 9 917
Invacare Poirier SAS • Route de St Roch • F-37230 Fondettes • Tel:
Switzerland
Deutschland
Portugal
Invacare AG • Benkenstrasse 260 • CH-4108 Witterswil • Tel.: (41)
Invacare GmbH • Alemannenstraße 10 • D-88316 Isny • Tel: (49)
Invacare Lda • Rua Estrada Velha • 949 • P-4465-784 Leça do Balio
• Tel: (351) (0)225 1059 46/47 • Fax: (351) (0)225 1057 39 •
España
Invacare SA • c/Areny s/n • Polígon Industrial de Celrà • E-17460
Celrà (Girona)Tel: (34) (0)972 49 32 00 • Fax: (34) (0)972 49 32 20
Belgium & Luxemburg
Nederland
Norge
Invacare nv • Autobaan 22 • B-8210 Loppem • Tel: (32) (0)50
83 10 10 • Fax: (32) (0)50 83 10 11 • [email protected] •
Invacare BV • Celsiusstraat 46 • NL-6716 BZ Ede • Tel: (31) (0)318
695 757 • Fax: (31) (0)318 695 758 • [email protected] •
Invacare AS • Grensesvingen 9 • Postboks 6230 • Etterstad •
N-0603 Oslo • Tel: (47) (0)22 57 95 00 • Fax: (47) (0)22 57 95 01•
Invacare Austria GmbH • Herzog Odilostrasse 101 • A-5310
Mondsee • Tel: (43) 6232 5535 0 • Fax: (43) 6232 5535 4 •
Österreich
USA
Invacare Corporation Worldwide Headquarters • One Invacare
Way • Elyria, Ohio 44036 • Tel: (800) 333 6900 • Fax: (877) 619
Canada
Invacare Canada • 570 Matheson Blvd. East, Unit 8 • Mississauga,
Ontario L4Z 4G4 • Tel: (800) 668 5324 • Fax: (800) 668 5478 •
Download from Www.Somanuals.com. All Manuals Search And Download.
Manufacturer
V. Guldmann A/S
Graham Bells Vej 21–23A
DK-8200 Aarhus N, Denmark
EU Representative
Invacare Limited
Pencoed Technology Park
Pencoed, Bridgend CF35 5AQ
United Kingdom
Invacare Corporation
USA
One Invacare Way
Elyria, Ohio USA
44036–2125
800–333–6900
1183377-B
2013-06-26
Making Life’s
Experiences Possible™
*1183377B*
Download from Www.Somanuals.com. All Manuals Search And Download.
|